Tripp Lite 0SU52015 Quick Installation Manual

Text of the manual

w w w . m i n i c o m . c o m

International HQ Jerusalem, Israel Tel: + 972 2 535 9666 [email protected] North American HQ Linden, NJ, USA Tel: + 1 908 486 2100 [email protected] Customer support - [email protected] 5UM20094 V1.8 4/09 Universal Phantom Manager Quick Installation Guide UNIVERSAL PHANTOM MANAGER 1 1. What is the Phantom system? The Phantom system from Minicom is a distributed KVM switching solution for 1 or more users. In the 1-User system a Manager controls the remote computers that are connected to Phantom Remote units. The Remote units can be either PCI cards or boxes called Specters. For multi-user functionality add a Phantom MX II. The Phantom system supports mixed type and multi-platform computers. In the 1-User system, shielded CAT5 FTP cables connect the Phantom Manager to the nearest Remote, and that Remote to the next one, and so on, in a daisy chain pattern. The last Remote can be up to 110m/360ft away from the Manager. See the configuration diagram on page 4 showing both Remote PCI cards and Specters in the Phantom system. The Multi-User system connects in a loop – as explained in Phantom MX II guide. This Quick Installation Guide illustrates the Universal Phantom Manager (UPM) and explains how to install it. For further information please see the softcopy Guide on the Marketing & Documentation CD. 2. Connecting a computer to the UPM To run the Phantom system the UPM does not need to be connected to a computer. A computer must be connected to the UPM to perform Phantom applications such as upgrading firmware or renumbering Remote units. This is discussed in detail in softcopy User Guide. When you do connect a computer use the 3 in 1 CPU cable illustrated below. 3. The UPM cables The cables below connect to the UPM. Shielded CAT5 FTP cable (Supplied with the Remote units) 3 in 1 CPU cable 4. Rack mounting The UPM is rack mountable. To obtain a 19” bracket, order P/N 5AC00202. QUICK INSTALLATION GUIDE 2 5. UPM accessories The accessories below are explained fully in the softcopy Guide. RS232 serial cable - For Phantom applications In Line Coupler - To bypass Remote units Terminator - Connects to last Remote in daisy chain 6. Pre-installation instructions Disconnect all computers from the electrical power supply. Cables should be placed away from fluorescent lights, air conditioners, and machines that are likely to generate electrical noise. Caution: For continued protection against risk of fire, replace with the same type and rating of fuse only. 7. Connecting the UPM The figure below illustrates the rear of the UPM. Mouse In port Terminal port System Out port RS232 port Power LED Power connector w w w . m i n i c o m . c o m USER COMPUTER SYSTEM SERVICE POWER 85-265VAC 50/60 Hz Keyboard Out port Mouse Out port Keyboard In port Video In port Video Out port Connect a keyboard, monitor, mouse plus the 3 in 1 CPU cable and Power cord to the UPM and computer as illustrated in the figure below. Connect the Power cord. Only use the power cord supplied with the UPM. Note! Connecting a computer and the 3 in 1 CPU cable is optional. UNIVERSAL PHANTOM MANAGER 3 To computer's Keyboard port To computer's Mouse port To computer's Video port 3 in 1 CPU cable SD P110 w w w . m i n i c o m . c o m USER COMPUTER SYSTEM SERVICE POWER 85-265VAC 50/60 Hz To System port To Phantom Remote System In port Shielded CAT5 FTP cable UPM 8. The Terminal port When using RS232 servers in the system, you have the option of operating these servers through the computer’s Terminal emulation or through an optional terminal connected to the Terminal port. 9. What happens next? Install the Phantom Remotes as explained in The Phantom Remote – Quick Installation Guide. Give the Remotes ID numbers and configure keyboard settings explained in the Read This First (RTF). The Phantom system is then ready for use.

QUICK INSTALLATION GUIDE

4 CAT5 cable ProLiant DL360 9.1 - GB 10k ULTRA2 SCSI 9.1 - GB 10k ULTRA2 SCSI ProLiant DL360 9.1 - GB 10k ULTRA2 SCSI 9.1 - GB 10k ULTRA2 SCSI ProLiant DL360 9.1 - GB 10k ULTRA2 SCSI 9.1 - GB 10k ULTRA2 SCSI ProLiant DL360 9.1 - GB 10k ULTRA2 SCSI 9.1 - GB 10k ULTRA2 SCSI ProLiant DL360 9.1 - GB 10k ULTRA2 SCSI 9.1 - GB 10k ULTRA2 SCSI ProLiant DL360 9.1 - GB 10k ULTRA2 SCSI 9.1 - GB 10k ULTRA2 SCSI w w w . m i n i c om . c o m USER COMPUTER SYSTEM SERVICE POWER 85-265VAC 50/60 Hz Link Active MINICOM www.minicom.com PHANTOM S p e c t e r Link Active MINICOM www.minicom.com PHANTOM S p e c t e r Link Active MINICOM www.minicom.com PHANTOM S p e c t e r Link Active MINICOM www.minicom.com PHANTOM S p e c t e r Link Active MINICOM www.minicom.com PHANTOM S p e c t e r 3 in 1 Cable S D P 1 1 0 RS232 Serial Cable Optional ProLiant DL360 9.1 - GB 10k ULTRA2 SCSI 9.1 - GB 10k ULTRA2 SCSI ProLiant DL360 9.1 - GB 10k ULTRA2 SCSI 9.1 - GB 10k ULTRA2 SCSI ProLiant DL360 9.1 - GB 10k ULTRA2 SCSI 9.1 - GB 10k ULTRA2 SCSI Link Active MINICOM www.minicom.com PHANTOM S p e c t e r Link Active MINICOM www.minicom.com PHANTOM S p e c t e r OUT IN OUT IN UPM The Phantom system configuration UNIVERSAL PHANTOM MANAGER 5 10. USB / SUN Combo keys The PS/2 keyboard connected to the Phantom Manager does not have a special SUN keypad to perform special functions in the SUN Operating System environment. So when a Specter USB or SUN is connected to a SUN computer, the Specters emulate these SUN keys using a set of key combinations called Combo keys. See the table below. SUN key Combo key Stop Left Ctrl + Left Alt + F1 Props Left Ctrl + Left Alt + F3 Front Left Ctrl + Left Alt + F5 Open Left Ctrl + Left Alt +F7 Find Left Ctrl + Left Alt + F9 Again Left Ctrl + Left Alt + F2 Undo Left Ctrl + Left Alt + F4 Copy Left Ctrl + Left Alt + F6 Paste Left Ctrl + Left Alt + F8 Cut Left Ctrl + Left Alt + F10 Help Left Ctrl + Left Alt + F11 Compose Application key or Left Ctrl + Left Alt + Keypad * Crescent Scroll Lock Volume Up Left Ctrl + Left Alt + Keypad – Volume Down Left Ctrl + Left Alt + Keypad + Mute Left Ctrl + Left Alt + F12 Sun Left ◊ key Left Windows key Sun Right ◊ key Right Windows key Alt-Graph Right Alt or Alt Gr Stop A Left Ctrl + Left Alt +1 QUICK INSTALLATION GUIDE 6 11. User guide feedback Your feedback is very important to help us improve our documentation. Please email any comments to: [email protected] Please include the following information: Guide name, part number and version number (as appears on the front cover). 12. WEEE compliance WEEE Information for Minicom Customers and Recyclers Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations, when customers buy new electrical and electronic equipment from Minicom they are entitled to: • Send old equipment for recycling on a one-for-one, like-for-like basis (this varies depending on the country) • Send the new equipment back for recycling when this ultimately becomes waste Instructions to both customers and recyclers/treatment facilities wishing to obtain disassembly information are provided in our website www.minicom.com. 2009 © Copyright Minicom Advanced Systems UNIVERSAL PHANTOM MANAGER 7

Other Switch Manuals