Process Control System PCS 7

Help for SIMATIC PDM (V8.2) Operating Manual SIMATIC PDM V8.2 02/2014 A5E33203676-AA Preface 1 Using SIMATIC PDM 2 Installation 3 PDM Exportfile Converter 4 Integrating devices into SIMATIC PDM 5 Views 6 Functions 7 Menus and dialog boxes in SIMATIC PDM 8 Menus and dialog boxes for SIMATIC PDM in the SIMATIC Manager 9 Menus and dialog boxes for SIMATIC PDM in HW Config 10 PDM Web 11 Notes, Tips & Tricks 12 Appendix A

Warning notice system

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY A5E33203676-AA Ⓟ 03/2014 Subject to change Copyright © Siemens AG 2014. All rights reserved

Table of contents

1 Preface.........................................................................................................................................................9 2 Using SIMATIC PDM..................................................................................................................................11 2.1 Introduction..................................................................................................................................11 2.2 Using the documentation.............................................................................................................11 2.3 Contact partner............................................................................................................................11 2.4 Basis for using intelligent field devices........................................................................................12 2.5 Establishing connections to field devices....................................................................................13 2.6 Product structure.........................................................................................................................18 2.6.1 Basic packages...........................................................................................................................18 2.6.2 Options........................................................................................................................................20 2.6.3 Delivery contents.........................................................................................................................22 3 Installation..................................................................................................................................................23 3.1 Preparing SIMATIC PDM............................................................................................................23 3.2 Installing SIMATIC PDM..............................................................................................................23 3.3 Setting the language...................................................................................................................26 3.4 Reinstalling / Removing SIMATIC PDM......................................................................................27 4 PDM Exportfile Converter...........................................................................................................................29 4.1 "PDM Exportfile Converter" dialog box........................................................................................29 5 Integrating devices into SIMATIC PDM......................................................................................................31 5.1 Device Integration Manager........................................................................................................31 5.2 "Device Integration Manager" main window................................................................................32 5.3 Views...........................................................................................................................................32 5.3.1 Title bar.......................................................................................................................................32 5.3.2 Menu bar.....................................................................................................................................33 5.3.3 Toolbar........................................................................................................................................34 5.3.4 Device list....................................................................................................................................35 5.3.5 Status bar....................................................................................................................................38 5.3.6 Source folder...............................................................................................................................38 5.3.7 Applying a filter............................................................................................................................38 5.3.8 Filter file/Project filter...................................................................................................................39 5.4 Working with the Device Integration Manager.............................................................................40 5.4.1 Integrating device descriptions....................................................................................................40 5.4.2 Completing a device description.................................................................................................41 5.4.3 Creating your own device library using the project filter..............................................................42 5.4.4 Creating your own device library from a collection of device descriptions..................................43 5.4.5 Removing device descriptions.....................................................................................................44 5.4.6 Update/upgrade of device descriptions (EDD update)................................................................44 Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 3

Menus and dialog boxes.............................................................................................................45

5.5.1 File...............................................................................................................................................45 5.5.1.1 Read device descriptions from source directory.........................................................................45 5.5.1.2 Read device descriptions from compressed source....................................................................45 5.5.1.3 List of integrated device descriptions..........................................................................................46 5.5.1.4 List of device descriptions used..................................................................................................46 5.5.1.5 Save device list...........................................................................................................................47 5.5.1.6 Print device list............................................................................................................................47 5.5.1.7 Deleting the device list................................................................................................................48 5.5.1.8 Exit..............................................................................................................................................48 5.5.2 View.............................................................................................................................................48 5.5.2.1 Split device list window................................................................................................................48 5.5.3 Catalog........................................................................................................................................49 5.5.3.1 Complete device information.......................................................................................................49 5.5.3.2 Integrate......................................................................................................................................50 5.5.3.3 User-specific device DVD ...........................................................................................................50 5.5.3.4 Filter file.......................................................................................................................................51 5.5.3.5 Project filter.................................................................................................................................51 5.5.3.6 Messages....................................................................................................................................52 5.5.3.7 Find.............................................................................................................................................53 5.5.4 ? (Help)........................................................................................................................................53 5.5.4.1 Help.............................................................................................................................................53 5.5.4.2 Info..............................................................................................................................................54 6 Views..........................................................................................................................................................55 6.1 Introduction..................................................................................................................................55 6.2 Views in SIMATIC Manager........................................................................................................55 6.2.1 Process devices plant view.........................................................................................................55 6.2.2 Process devices network view....................................................................................................56 6.2.3 Open SIMATIC PDM in the Process Devices - Plant View.........................................................57 6.2.4 Project synchronization...............................................................................................................57 6.3 Views in SIMATIC PDM..............................................................................................................58 6.3.1 Main Window "SIMATIC PDM"....................................................................................................58 6.3.2 Title bar.......................................................................................................................................59 6.3.3 Menu bar.....................................................................................................................................59 6.3.4 Toolbar........................................................................................................................................60 6.3.5 Structure view..............................................................................................................................60 6.3.6 Parameter table...........................................................................................................................61 6.3.6.1 "Parameter" column of the parameter table................................................................................62 6.3.6.2 "Value" column of the parameter table........................................................................................62 6.3.6.3 "Unit" column of the parameter table...........................................................................................63 6.3.6.4 "Status" column of the parameter table.......................................................................................63 6.3.7 Status bar....................................................................................................................................64 6.3.8 Display ........................................................................................................................................64 6.3.8.1 Display in the views.....................................................................................................................64 6.3.8.2 Stand-alone device view.............................................................................................................65 6.3.8.3 Multiple devices view...................................................................................................................66 6.3.9 Keyboard operation.....................................................................................................................66 Table of contents Help for SIMATIC PDM (V8.2) 4 Operating Manual, 02/2014, A5E33203676-AA

"Settings" for the SIMATIC project..............................................................................................71

7.2.2 Setting the interface on the computer.........................................................................................73 7.2.3 Plant-wide communication by means of routing..........................................................................74 7.2.4 Checking the device integration..................................................................................................74 7.2.5 Print.............................................................................................................................................75 7.2.6 Cleaning the project (reorganization) .........................................................................................76 7.2.7 Saving the configuration..............................................................................................................77 7.3 Device management ..................................................................................................................77 7.3.1 Inserting devices.........................................................................................................................77 7.3.1.1 Inserting objects..........................................................................................................................77 7.3.1.2 "Insert Object - <...>" dialog box..................................................................................................78 7.3.1.3 "Insert Object - Assign Device Type" dialog box.........................................................................79 7.3.1.4 Integrating a device in HW Config...............................................................................................81 7.3.1.5 Setting the bus address in HW Config........................................................................................83 7.3.1.6 Integrating a HART device in a HART modem network..............................................................84 7.3.1.7 Integrating a MODBUS device in a MODBUS network...............................................................86 7.3.1.8 Integrating a HART server network.............................................................................................88 7.3.1.9 Compact PROFIBUS device (sensors and actuators)................................................................94 7.3.1.10 Modular PROFIBUS device (remote I/O)....................................................................................95 7.3.1.11 Connecting a field device to PROFINET.....................................................................................97 7.3.1.12 HART device on remote I/O........................................................................................................99 7.3.1.13 Inserting a HART device at a HART module.............................................................................102 7.3.1.14 Integrating an FF field device....................................................................................................102 7.3.2 Field devices with redundant bus connection ...........................................................................103 7.3.2.1 Connecting field devices to a redundant bus system................................................................103 7.3.2.2 "Select object" dialog box..........................................................................................................104 7.3.2.3 "Properties - Find object" dialog box.........................................................................................104 7.3.3 Using unspecified PROFIBUS PA devices as placeholders.....................................................104 7.3.4 Creating typicals for parameters (import without ID data) ........................................................105 7.3.5 Replacing devices.....................................................................................................................106 7.3.6 Inserting plant-specific documents for process mode...............................................................107 7.3.7 Operating modes of field devices..............................................................................................108 7.3.8 Deleting devices........................................................................................................................109 7.3.9 Assigning parameters and downloading to devices..................................................................110 7.3.10 Interconnecting and downloading FF devices...........................................................................110 7.3.10.1 “Interconnection Editor" dialog box...........................................................................................110 7.3.10.2 Downloading objects in the FF segment...................................................................................112 7.4 Communication.........................................................................................................................114 7.4.1 Saving/reading the device data.................................................................................................114 7.5 Export / Import...........................................................................................................................116 7.5.1 Introduction................................................................................................................................116 7.5.2 Exporting configuration and parameter assignment data..........................................................119 7.5.3 Importing configuration and parameter assignment data..........................................................120 7.6 Diagnostics................................................................................................................................122 7.6.1 Field device diagnostics............................................................................................................122 7.6.2 Overview of Device Icons..........................................................................................................124 Table of contents Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 5

Working with the LifeList...........................................................................................................127

7.7.2 Licensing...................................................................................................................................132 7.7.3 Menus and dialog boxes...........................................................................................................133 7.7.3.1 "File" menu................................................................................................................................133 7.7.3.2 "Edit" menu................................................................................................................................133 7.7.3.3 "Device" menu...........................................................................................................................134 7.7.3.4 "View" menu..............................................................................................................................136 7.7.3.5 "Options" menu.........................................................................................................................136 7.7.3.6 "Help" menu..............................................................................................................................136 7.7.4 Menu bar...................................................................................................................................137 7.7.5 Toolbar......................................................................................................................................137 7.7.6 Status bar..................................................................................................................................138 7.8 Logs...........................................................................................................................................138 7.8.1 Message log..............................................................................................................................138 7.9 Graphical displays.....................................................................................................................139 7.9.1 Graphical display of values.......................................................................................................141 7.9.2 Trend chart................................................................................................................................142 7.9.3 Bar chart....................................................................................................................................144 7.9.4 Tachometer chart......................................................................................................................145 7.9.5 Icons and buttons......................................................................................................................146 7.9.6 Work with trends........................................................................................................................147 7.9.7 Editing trends............................................................................................................................149 7.10 Asset management...................................................................................................................151 7.10.1 Asset management ..................................................................................................................151 7.10.2 Use with the PCS 7 Maintenance Station.................................................................................152 8 Menus and dialog boxes in SIMATIC PDM .............................................................................................155 8.1 "File" menu ...............................................................................................................................155 8.1.1 Save..........................................................................................................................................155 8.1.2 Exporting...................................................................................................................................155 8.1.2.1 "Export - " dialog box........................................................................................156 8.1.3 Importing...................................................................................................................................158 8.1.3.1 "Import - " dialog box........................................................................................158 8.1.4 Print...........................................................................................................................................161 8.1.5 Exit............................................................................................................................................162 8.1.5.1 "Save changes?" dialog box......................................................................................................162 8.2 Editing (depends on device)......................................................................................................163 8.3 "Device" menu...........................................................................................................................163 8.3.1 Download to device...................................................................................................................163 8.3.1.1 "Download to Device - <...>" dialog box....................................................................................164 8.3.2 Upload to PG/PC.......................................................................................................................165 8.3.2.1 "Upload to PG/PC - <...>" dialog box........................................................................................166 8.3.3 Value comparison......................................................................................................................168 8.3.3.1 Value comparison......................................................................................................................168 8.3.3.2 "Value Comparison" dialog box.................................................................................................168 Table of contents Help for SIMATIC PDM (V8.2) 6 Operating Manual, 02/2014, A5E33203676-AA

"Select object" dialog box..........................................................................................................169

8.3.4 Assign address and TAG..........................................................................................................169 8.3.4.1 "Assign address and TAG..." dialog box...................................................................................171 8.3.5 Object properties.......................................................................................................................172 8.3.5.1 "General" tab.............................................................................................................................173 8.3.5.2 "Device" tab...............................................................................................................................173 8.3.5.3 "Diagnostics" tab.......................................................................................................................174 8.3.5.4 "Communication" tab.................................................................................................................174 8.3.5.5 "Document Manager" tab..........................................................................................................176 8.3.6 Calibration log...........................................................................................................................176 8.3.6.1 Calibration log...........................................................................................................................176 8.3.6.2 Menus and dialog boxes...........................................................................................................178 8.3.6.3 Menu bar...................................................................................................................................183 8.3.6.4 Toolbar......................................................................................................................................183 8.3.7 Change log................................................................................................................................184 8.3.7.1 Show change log.......................................................................................................................184 8.3.7.2 Menus and dialog boxes...........................................................................................................185 8.3.7.3 Menu bar...................................................................................................................................187 8.3.7.4 Toolbar......................................................................................................................................187 8.4 "View" menu .............................................................................................................................188 8.4.1 Process variables / Measured value display (depends on device)............................................188 8.4.2 Start LifeList..............................................................................................................................189 8.4.3 Charts and trends (depends on device)....................................................................................189 8.4.3.1 Displaying process variables and measured values ................................................................190 8.5 "Diagnostics" menu...................................................................................................................191 8.5.1 Update diagnostics....................................................................................................................191 8.5.1.1 "Update diagnostics - <...>" dialog box.....................................................................................191 8.6 "Options" menu (depends on device)........................................................................................193 8.7 "Help" menu..............................................................................................................................193 8.7.1 Contents....................................................................................................................................193 8.7.2 Help for device parameters.......................................................................................................193 8.7.3 Info............................................................................................................................................193 8.7.4 Find...........................................................................................................................................194 8.7.5 Document Manager...................................................................................................................194 9 Menus and dialog boxes for SIMATIC PDM in the SIMATIC Manager....................................................195 9.1 "Edit" menu................................................................................................................................195 9.1.1 SIMATIC Manager > "Edit" menu..............................................................................................195 9.1.2 Object properties.......................................................................................................................195 9.1.2.1 "General" tab.............................................................................................................................196 9.1.2.2 "Device" tab...............................................................................................................................197 9.1.2.3 "Diagnostics" tab.......................................................................................................................197 9.1.2.4 "Communication" tab.................................................................................................................197 9.1.2.5 "Document Manager" tab..........................................................................................................199 9.1.3 SIMATIC PDM...........................................................................................................................200 9.1.3.1 Exporting...................................................................................................................................200 9.1.3.2 Importing...................................................................................................................................200 9.1.3.3 Download to device...................................................................................................................200 9.1.3.4 Upload to PG/PC.......................................................................................................................201 9.1.3.5 Update diagnostics....................................................................................................................202 Table of contents Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 7

Device selection (Reassign)......................................................................................................202

9.1.3.8 Show change log.......................................................................................................................204 9.2 "Insert" menu.............................................................................................................................205 9.2.1 Inserting an object.....................................................................................................................205 9.3 "View" menu .............................................................................................................................207 9.3.1 Process devices plant view.......................................................................................................207 9.3.2 Process devices network view..................................................................................................208 9.4 "Options" menu.........................................................................................................................208 9.4.1 Settings for SIMATIC PDM........................................................................................................210 9.4.1.1 Settings for SIMATIC PDM........................................................................................................210 9.4.1.2 "General" tab.............................................................................................................................211 9.4.1.3 "Communication" tab.................................................................................................................212 9.4.1.4 The "Load" tab...........................................................................................................................213 9.4.1.5 "Device Integration Manager" tab..............................................................................................213 9.4.1.6 "Maintenance Station" tab.........................................................................................................215 9.4.1.7 "Change Log" tab......................................................................................................................215 9.4.1.8 "Service" tab..............................................................................................................................215 9.4.2 Role management.....................................................................................................................217 9.4.3 HART server..............................................................................................................................218 10 Menus and dialog boxes for SIMATIC PDM in HW Config.......................................................................221 11 PDM Web.................................................................................................................................................223 11.1 Setting up SIMATIC PDM Web.................................................................................................223 11.2 PDM Web Server Configurator..................................................................................................225 11.3 Web login..................................................................................................................................227 11.4 Menus and dialog boxes for SIMATIC PDM in PDM Web........................................................227 11.4.1 "File" menu................................................................................................................................227 11.4.2 "Device" menu...........................................................................................................................228 11.4.3 "View" menu..............................................................................................................................228 11.4.4 "Diagnostics" menu...................................................................................................................228 11.4.5 "Help" menu..............................................................................................................................228 12 Notes, Tips & Tricks.................................................................................................................................229 12.1 Information on configuration and parameter assignment..........................................................229 12.2 Connecting field devices by means of Industrial Ethernet.........................................................230 12.3 HART applications.....................................................................................................................232 A Appendix...................................................................................................................................................233 A.1 Communication Problems.........................................................................................................233 A.2 Message window.......................................................................................................................235 A.2.1 "Decision on error" dialog box...................................................................................................235 A.2.2 "Error history" dialog box...........................................................................................................235 A.2.3 "Error" dialog box......................................................................................................................235 A.2.4 "Multiple errors" dialog box........................................................................................................235 A.2.5 "Messages" Dialog Box.............................................................................................................235 Index.........................................................................................................................................................237 Table of contents Help for SIMATIC PDM (V8.2) 8 Operating Manual, 02/2014, A5E33203676-AA

Purpose of the program

SIMATIC PDM (Process Device Manager) is a general-purpose, manufacturer-independent tool for the configuration, parameter assignment, commissioning, diagnostics, and maintenance of intelligent field devices (sensors and actuators) and field components (remote I/O, multiplexers, control room devices, compact controllers). Purpose of the documentation This documentation supports you in your work with SIMATIC PDM software. You are provided with an overview of the following topics: ● Installing SIMATIC PDM (Page 23) ● Commissioning the software ● Procedures for configuring networks and field devices ● Procedures for commissioning and using the Runtime functions Required basic knowledge The documentation is intended for persons working in field engineering who are responsible for configuration, commissioning and plant operation. General knowledge in the area of field engineering is required to understand this documentation. Knowledge about the use of Windows operating systems is also required. Activities using STEP 7 and PCS 7 require corresponding knowledge in the field of automation technology and of SIMATIC S7. Validity This documentation is valid for the SIMATIC PDM V8.2 software package. Device-specific help This documentation only covers the basic functionality of PDM. For device-specific information, refer to the documentation of the field device manufacturers. Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 9

Readme for SIMATIC PDM

For details of the requirements for using SIMATIC PDM, of special functions, and of the various applications, see file pdmbase-readme. You can locate the file as follows: ● On the SIMATIC PDM product DVD in the main folder of the DVD ● On the SIMATIC PCS 7 product DVD in the folder ...PDM...\PDMBASE\setup ● After installation of SIMATIC PDM: – By selecting SIEMENS SIMATIC documentation in the Windows Start menu – The default folder for the file is ...\SIEMENS\SIMATIC_PDM\. Online help The SIMATIC PDM online help is a project-specific help feature, which contains the following information: ● Help for SIMATIC PDM The PDF file is an extract of the HTML-based online help for SIMATIC PDM. The PDF file does not contain any device-specific information. ● Device-specific help Device-specific information contained in the online help is derived from the device descriptions (EDD) of the devices being used: – Information on device-specific functions (e.g. available online functions) – Help for device-specific menu commands (e.g. trend display options, device-specific display functions and operating functions) Note Scope of the device-specific information The scope of the device-specific information depends on what information can be derived from the device descriptions. The help system is integrated into the software by way of several interfaces: ● The Help menu provides several menu commands: Help Topics opens the help for SIMATIC PDM. ● The context-sensitive help provides information with regard to the current context such as open dialog boxes or active windows. The help is called by clicking the "Help" button or by pressing the F1 key. ● A tooltip is displayed for the toolbar icons when the user hovers the mouse pointer over the icons. If you would prefer to read a hardcopy of the help, you can print specific help topics or chapters, or the entire help. Preface Help for SIMATIC PDM (V8.2) 10 Operating Manual, 02/2014, A5E33203676-AA

Using SIMATIC PDM

2 2.1 Introduction SIMATIC PDM (Process Device Manager) is a general-purpose, manufacturer-independent tool for configuration, parameter assignment, commissioning, diagnostics and maintenance of intelligent field devices (sensors and actuators) and field components (remote I/Os, multiplexers, control room units, compact controllers). These are simply referred to as devices in the rest of this documentation. With one software package, SIMATIC PDM enables processing of more than 2500 devices from Siemens and 200 other manufacturers from around the world with an homogeneous user interface. 2.2 Using the documentation Scope SIMATIC PDM operates within a SIMATIC STEP 7 / PCS 7 environment or in combination with suitable function modules. Conventions The names of the user interfaces in this software are listed in accordance with the regional language of this documentation. If you have installed an MUI operating system, certain designations are still displayed in the base language of the operating system after a language change and will, therefore, differ from those used in the documentation. 2.3 Contact partner Your contact partner (not for demo version) Questions on SIMATIC STEP 7 / SIMATIC PCS 7 / hardware / SIMATIC PDM / problems with S7 communication Mailing address: SIEMENS AG Customer Support D-90475 Nuremberg, Germany E-mail: [email protected] Internet: http://www.siemens.com/automation/service&support (http:// www.siemens.com/automation/service&support) Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 11

Questions on devices and GSD files

Please get in touch with your contact partner at the device manufacturer. For more information, refer to the "List of integrated devices". You will find this on the "SIMATIC PDM Device Library 1#2014" DVD in the "\_manuals" directory. Follow-up installations and additional information on SIMATIC PDM are available on the Internet at "Auto-Hotspot". See also www.siemens.com/simatic-pdm (www.siemens.de/simatic-pdm) 2.4 Basis for using intelligent field devices Integration of field devices from different manufacturers into control systems Device descriptions had to be standardized In order to enable intelligent field devices from different manufacturers to be integrated into different control systems. This standard (IEC 61804-2) was developed in collaboration with the following organizations: ● PROFIBUS User Organization (PNO) ● Hart Communication Foundation (HCF) ● Fieldbus FOUNDATION (FF) ● OPC Foundation Device descriptions are based on EDDL (Electronic Device Description Language - standard IEC 61804-3). Finding the device description You can obtain device descriptions in the following ways: ● From the device manufacturer together with the device ● On the Internet ● In the device catalogs of applications that can evaluate data contained in device descriptions Note Device descriptions and EDD Below, only the term "device description" will be used to refer to "EDD" (Electronic Device Description) and "DD" (Device Description). However, the terms EDD and DD appear in the user interface. Using SIMATIC PDM 2.4 Basis for using intelligent field devices Help for SIMATIC PDM (V8.2) 12 Operating Manual, 02/2014, A5E33203676-AA

Siemens explicitly declines any liability for damages resulting from the use of the following

device description files and use in conjunction with the associated devices: ● For device-specific device description files for non-Siemens devices, the Siemens warranty only applies up to the interface. ● For non-device-specific device description files, such as those that correspond to the PROFIBUS PA profiles or the HART universal or common practice commands ● For device description files of the HCF library from the "Device Library" DVD ● For device description files integrated through catalogs NOTICE Important note on the device description files included with the SIMATIC PDM The device description files of non-Siemens field devices have not been developed by Siemens and are included with the shipped products free of charge. The licensee is entitled to use the device description files of these devices in the same manner as a trial license in accordance with the general terms and conditions for the supply of software for automation and drive technology. This right of use may be exercised by the licensee as long as the right of use for the PDM software is in effect. 2.5 Establishing connections to field devices Plants use field devices with different communication paths and protocols. The overview shows a typical connection scenario for the field device groups that are supported by SIMATIC PDM. Using SIMATIC PDM 2.5 Establishing connections to field devices Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 13

Network topologies for PROFIBUS DP

The following figure shows the access paths to field devices for SIMATIC PDM. ������������ ������������� ������������� ������������� ������������� ����������� ������� ���������� ���� ����� ������������ ������� ��� ����������� ����������� �������� ����������� ����������� ����������� ����������� ����������� ������������������� ������������������� � Using SIMATIC PDM 2.5 Establishing connections to field devices Help for SIMATIC PDM (V8.2) 14 Operating Manual, 02/2014, A5E33203676-AA

Network topologies for PROFINET

The following figure shows the access paths to field devices for SIMATIC PDM. ������������� �������������������� ����������������� ���������������� ������������ ����������� ���������� ��������������� ������������� ������������� �������� �������� �������� �������� ����������� ���������� ���� ����� ������������ ������� ��� Communication paths Note Interface with SIMATIC PDM The PC shown is always the interface to SIMATIC PDM. In networks with routing capability, the PC can be connected to a linked network. You can find information on this in the section "Plant-wide communication by means of routing (Page 74)". Using SIMATIC PDM 2.5 Establishing connections to field devices Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 15

HART modem network

The following figure shows the access paths to field devices for SIMATIC PDM. ��������������� MODBUS network The following figure shows the access paths to field devices for SIMATIC PDM. ������ HART server network The following figure shows the access paths to field devices for SIMATIC PDM. Using SIMATIC PDM 2.5 Establishing connections to field devices Help for SIMATIC PDM (V8.2) 16 Operating Manual, 02/2014, A5E33203676-AA

With this version of SIMATIC PDM, field devices are supported on the following networks:

● PROFIBUS DP network (including subordinate Foundation Fieldbus) ● PROFIBUS PA network ● PROFINET ● MODBUS network ● HART modem network ● HART server Activating PDM functions License keys are required in order to use SIMATIC PDM. You can expand the SIMATIC PDM functions by adding optional packages. You can find information on this in the section "Basic packages (Page 18)". Using SIMATIC PDM 2.5 Establishing connections to field devices Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 17

Section "Inserting devices (Page 77)"

2.6 Product structure 2.6.1 Basic packages The following product packages with different performance features are available for SIMATIC PDM. Product packages for SIMATIC PDM V8.2 Legend for the tables: ●: Available ○: Optionally available -: Not available License key SIMATIC PDM product package Stand-alone STEP 7 PCS 7 SIMATIC PDM Basic and Extended - ● ● SIMATIC PDM Single Point ● - - Integration in STEP 7 - ● ● TAGs - 100 100 "SIMATIC PDM Routing (Page 20)" optional package - ○ ● SIMATIC Logon Service V1.5 SP2* - ○ ● * The SIMATIC Logon Service option requires a license for the following applications: ● SIMATIC PDM stand alone ● SIMATIC PDM integrated in STEP 7 Within SIMATIC PCS 7, no separate license is necessary. Note Displaying devices subject to licensing SIMATIC PDM will only display devices if a TAG license is installed for each device subject to licensing. ● Licenses are only required for devices that are subject to licensing. ● No licenses are required for remote I/O modules and channels. Using SIMATIC PDM 2.6 Product structure Help for SIMATIC PDM (V8.2) 18 Operating Manual, 02/2014, A5E33203676-AA

Functions in product package

Functions SIMATIC PDM Single Point STEP 7 PCS 7 Project functions ● Create online ● ● ● ● TAG options used - ● ● ● Network view ● ● ● ● Plant view ● ● ● ● Export / import devices - ● ● ● HW Config - ● ● ● Integration in STEP 7 - ● ● Communication functions ● PROFIBUS ● ● ● ● PROFINET ● ● ● ● FOUNDATION Fieldbus - ○ ○ ● MODBUS ● ● ● ● S7 DSGW - ○ ● ● HART modem ● ● ● ● HART interface network ● ● ● ● HCF HART server - ○ ○ ● HART SHC mode (communication acceleration) ● ● ● Device functions ● Use of SIMATIC PDM options - ● ● ● Saving parameters ● ● ● ● Log (audit trail) - ● ● LifeList functions ● Scan from HW Config - ● ● ● Device diagnostics - ● ● ● Define scan area ● ● ● ● Scan from network view ● ● ● SIMATIC PDM Single Point SIMATIC PDM Single Point can be used for a single device. SIMATIC PDM Single Point cannot be extended with other options. Using SIMATIC PDM 2.6 Product structure Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 19

Operating mode "PDM Demo"

The "PDM Demo" version is an operating mode especially for the product SIMATIC PDM. The "PDM Demo" operating mode is activated automatically if necessary licenses are not recognized or functions/options that are subject to licensing are present in a project. ● Necessary licenses for SIMATIC PDM (license keys): – SIMATIC PDM Basic ● Functions/options subject to licensing: – Options subject to licensing (for example SIMATIC PDM Extended) Reaction After starting SIMATIC PDM, you receive a message stating that demo mode is activated. In addition, the status line displays the information "Demo". Note License conditions violated If the license conditions are violated, the following applies: ● The processing of the project with other editors is unrestricted. ● Objects that are not affected by the infringement of the license conditions can be created. ● The communication functions are locked. ● Online dialog boxes of field devices can only be opened "offline". 2.6.2 Options Program Add-ons for SIMATIC PDM SIMATIC PDM Single Point can only be used for a single device. SIMATIC PDM Single Point cannot be extended with other functional or TAG options. For SIMATIC PDM, the following options can be purchased: ● SIMATIC PDM Integration in STEP 7 (PCS 7) It allows field devices and their associated networks to be configured using the STEP 7 hardware configurator (HW Config). Note The combination of SIMATIC PDM and the option "Integration in STEP 7" is referred SIMATIC PDM integrated in the remainder of this documentation. Using SIMATIC PDM 2.6 Product structure Help for SIMATIC PDM (V8.2) 20 Operating Manual, 02/2014, A5E33203676-AA

SIMATIC PDM TAG

If you want to use more TAGs for each multiproject or project than those provided in the standard package, the TAG options of SIMATIC PDM enable you to expand the TAGs to the required number. By combining multiple license keys, you can reach the required number of devices for licensing (TAG addition). Available license keys: – 10 TAG – 100 TAG – 1000 TAG ● SIMATIC PDM Foundation Fieldbus This option licenses and allows configuration and communication of field devices on the Foundation Fieldbus in SIMATIC S 7 and SIMATIC PCS 7 projects. ● SIMATIC PDM Routing Licenses and enables the use of the following gateways: – Communication via an automation system which serves as a gateway – Communication between Ethernet and PROFIBUS – Communication between PROFINET and PROFIBUS The option is not required for the following gateways: – PROFIBUS to PROFIBUS – PROFIBUS to HART – PROFINET to HART ● SIMATIC PDM Extended Licenses and enables the use of the following additional functions: – Import and export of parameter sets and project structures – Print – Document Manager – Extended functionality of the LifeList – Change log – Calibration log for each field device – Configuration of three time intervals (maintenance, servicing, calibration) for each field device ● SIMATIC PDM HART Server Licenses and enables the use of the HCF HART Server and thereby the HART multiplexers with connected HART field devices and and wireless HART field devices. ● SIMATIC PDM Command Interface The command interface enables the integration of SIMATIC PDM in other automation systems. SIMATIC PDM projects and objects in these projects can be edited and operated through this interface. The use of this interface requires advanced programming skills. It should not be used in SIMATIC PCS 7 projects. For more information, refer to the documentation for the command interface. Using SIMATIC PDM 2.6 Product structure Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 21

Establishing connections to field devices (Page 13)

2.6.3 Delivery contents Scope of delivery Information about the software packages that are delivered with SIMATIC PDM can be found in the pdmbase-readme file. Device libraries Information on the devices contained in the SIMATIC PDM device libraries can be found: ● On the Internet pages of the device manufacturers The updated versions of the device libraries and the HCF catalog are available in publications on the Internet. ● On the "Device Library" DVD in the _manuals\PI_Library_Documentation > folder in file "index.html" Liability Note Read the information in the section "Basis for using intelligent field devices (Page 12)". Using SIMATIC PDM 2.6 Product structure Help for SIMATIC PDM (V8.2) 22 Operating Manual, 02/2014, A5E33203676-AA

PDM V8.2 is compatible with STEP7 V5.5 SP4 and PCS7 V8.1.

PCS7 V8.0x (STEP7 V5.5.3 and prior versions) are not supported. 3.1 Preparing SIMATIC PDM Requirement ● SIMATIC PDM is installed. You can find information on this in the section "Installing SIMATIC PDM (Page 23)" ● Project settings have been made. You can find information on this in the section ""Options" menu (Page 208)". ● The settings have been made for the fieldbus interfaces. ● Field device planning has been completed. You can find information on this in the section "Establishing connections to field devices (Page 13)" ● The device description files for the field devices used within a plant have been integrated into SIMATIC PDM. You can find information on this in the section "Integrating device descriptions (Page 40)". Recommendation: Hardware has been prepared (configuration, power supply, network connections). Additional information ● For additional information on assigning a network, refer to the section "Setting the interface on the computer (Page 73)". ● For information on the particular issues relating to the distributed I/O, refer to the section "Modular PROFIBUS device (remote I/O) (Page 95)". 3.2 Installing SIMATIC PDM SIMATIC PDM must be installed before it can be started. The software package contains all SIMATIC PDM software. Depending on the use case in question, you will only need to install certain applications from the CD. Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 23

In order to use the software you will need product-specific license keys (license agreements),

which you install with the Automation License Manager. You can transfer the required license keys either prior to or following the installation. You can find additional information on this in the online help for the Automation License Manager. Requirements ● The operating system has been installed. ● No version of SIMATIC PDM has been installed. ● All communications processors have been installed in the PC. ● You have administrator rights on the PC station. If you install the software in a domain, be aware of group policies or other restrictions that may hinder the installation. Consult the appropriate Administrator as regards these settings and the required approvals and permissions. Note Display of the dialog elements Dialog elements of SIMATIC PDM are only displayed correctly when the display settings in Windows are set to 100%. Bigger or smaller scaling lead to display errors. Calling the setup program 1. Insert the program CD into the drive. 2. Double-click on "Setup.exe" to start the setup. Note Checking the installation requirements The setup program automatically checks whether the software components needed for the installation are already installed on the PC. ● Read the latest information about installation and the software and hardware requirements in the pdmbase-readme file on the program CD. ● If any software components are missing, a message informs you of this. The setup program is terminated after the message is confirmed . The setup will start again after you have installed the missing software components. Installation 3.2 Installing SIMATIC PDM Help for SIMATIC PDM (V8.2) 24 Operating Manual, 02/2014, A5E33203676-AA

Settings in the setup

Below you will find information on the settings made in the setup dialog boxes, listed in the order in which they are processed: 1. Setup language – For example, click "English" and "Next". 2. Welcome – "Next" 3. Product information – Read this if needed and "Next" 4. License agreement – Activate the check box "I accept the conditions of the licensing agreement as well as the conditions of the Open Source Licensing Agreement". – "Next" 5. Setup type – Activate the "Install" check box and "Next". 6. User information – Enter the user information and click "Next". 7. Installation type – Package installation – Custom installation – You can specify the target folder for SIMATIC PDM. – "Next" 8. Programs – The software installed on the PC for this selection is listed in the display window. "Next" Note FOUNDATION Fieldbus If you wish to configure or monitor devices on FOUNDATION Fieldbus, you must select the "FOUNDATION Fieldbus" option. Installation 3.2 Installing SIMATIC PDM Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 25

9. System settings

System settings are required for problem-free operation of SIMATIC PDM. Note Required system settings ● The settings in the exception list of the Windows firewall are applied to the area of the local network (subnet). If your PC stations are located in different networks (subnets), you need to change this area. ● The settings in the exception list of the Windows firewall are made when the Windows firewall is disabled. ● You can open the "Security Controller" dialog box again. To do this, select the following in the Start menu, Siemens SIMATIC programs: Security > Security Controller 10.Ready to install the selection. "Install" - The installation is performed. Close the dialog box when the installation is complete. 11.Reboot the PC. Device descriptions of field devices used Following the installation of SIMATIC PDM, integrate the required device descriptions (EDD) for the field devices used. You can find information on this in the following sections: ● Section "Integrating devices into SIMATIC PDM (Page 31)" ● Section "Integrating device descriptions (Page 40)" 3.3 Setting the language Changing the language 1. In SIMATIC Manager, select the menu command Options > Settings… .The "Settings" dialog box opens. 2. Open the "Language" tab. You can change the language on this tab page. 3. Select the language you want to work with in the "National language" field. Note SIMATIC PDM language versions The drop-down list contains the languages in which SIMATIC Manager is installed. If you select a language for which there is no matching SIMATIC PDM language version installed on the given computer, "English" is set automatically. Installation 3.3 Setting the language Help for SIMATIC PDM (V8.2) 26 Operating Manual, 02/2014, A5E33203676-AA

Reinstalling / Removing SIMATIC PDM

Note Observe the information on dealing with license keys, which can be found in: ● File pdmbase-readme ● Help for the Automation License Manager Reinstalling Reinstallation over the top of an existing SIMATIC PDM version is not possible. Remove SIMATIC PDM prior to installing the new version. Note Device descriptions Following a new installation, the required device description must be integrated again. The device descriptions included with SIMATIC PDM are available on the "Device Library" DVD. You know the storage locations of additionally used device descriptions. You can find information about integrating the device descriptions in the section "Integrating devices into SIMATIC PDM (Page 31)". Removing To remove SIMATIC PDM, use the Windows system function for removing programs. Installation 3.4 Reinstalling / Removing SIMATIC PDM Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 27

PDM Exportfile Converter

4 4.1 "PDM Exportfile Converter" dialog box In the "PDM Exportfile Converter" dialog, you can convert export files from older PDM versions, enabling them to be imported into PDM again. The export files from PDM versions V6.x and V7.x cannot be imported directly into PDM V8. To enable importing of existing export files, the “old” export files are converted. A structure file is generated in this process and stored along with the associated parameter import files in the corresponding subdirectory generated by the converter. These files can then be imported. Source-File Navigate to the desired directory in the file system containing the export files to be converted. After the dialog is closed with OK and an export file is correctly selected, the structure it contains is displayed in the converter. Destination-Dir Navigate to the desired directory in the file system where the converted files are to be stored. "Convert" button Click "Convert". The selected source file is converted. Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 29

Integrating devices into SIMATIC PDM

5 5.1 Device Integration Manager The field devices can only be configured if the device descriptions that are suitable for the field devices have been integrated into SIMATIC PDM. The Device Integration Manager is the SIMATIC PDM function for integrating device descriptions. Liability Siemens explicitly declines any liability for damages resulting from the use of the following device descriptions and use in conjunction with the associated devices: ● For device-specific device descriptions for non-Siemens devices, the Siemens warranty only applies up to the interface. ● For non-device-specific device descriptions, such as device descriptions that correspond to the PROFIBUS PA profiles or the HART universal or common practice commands. ● For device descriptions of the HCF library, FF library, and PI library from the "Device Library ..." DVD. NOTICE Important information about the device descriptions included with the SIMATIC PDM The device descriptions of non-Siemens field devices were not developed by Siemens and are included with the shipped products free of charge. The licensee is entitled to use the device descriptions of these devices in the same manner as a trial license in accordance with the general terms and conditions for the supply of software for automation and drive technology. This right of use may be exercised by the licensee as long as the right of use for the PDM software is in effect. Starting the Device Integration Manager 1. In the Windows Start menu under the Siemens SIMATIC programs, select the SIMATIC PDM > Device Integration Manager menu command. The "Device Integration Manager" dialog opens. 2. Read the license agreement. You must accept the license agreement in order to be able to work with the Device Integration Manager . 3. Click the "I accept the license agreement" button. Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 31

"Device Integration Manager" main window

Introduction The "Device Integration Manager" main window remains on the screen throughout the work session and is partially or totally covered by other activated dialog windows. The main window has the following layout Title bar (Page 32) The product name is displayed. Menu bar (Page 33) You access the functions of the Device Integration Manager via the menu bar. Toolbar (Page 34) The toolbar enables certain menu commands to be accessed quickly. Source folder (Page 38) The "Source folder" box shows the storage location in which device descriptions are or were searched for. Applying a filter (Page 38) You can apply filters to reduce the amount of information displayed in the device list. Applying a project filter (Page 51) / Applying Filter File (Page 51) Only those devices that are used in the selected project and for which an identical version has not yet been integrated are selected for integration. Device list (Page 35) The device list displays information on devices that have been read in or integrated. Status bar (Page 38) Contains information on processes currently being performed. 5.3 Views 5.3.1 Title bar The title bar shows the name "Device Integration Manager". Integrating devices into SIMATIC PDM 5.3 Views Help for SIMATIC PDM (V8.2) 32 Operating Manual, 02/2014, A5E33203676-AA

Below you will find an overview of the Device Integration Manager menus.

Menu Submenu Function File ● Read device descriptions from source directory (Page 45) Select the storage location of the device descriptions to be read in. Set the path to the device descriptions or navigate to the location. ● Read device descriptions from compressed source (Page 45) Select the storage location of the compressed device descriptions to be read in. Set the path and the file name for compressed device descriptions or navigate to the location. ● List of integrated device descriptions (Page 46) The device descriptions integrated in the PC are read in to the device list. ● List of device descriptions used (Page 46) The device descriptions used in the STEP 7 project are displayed. ● Save device list (Page 47) The displayed information of the current device list is saved. Specify the storage location and file name for the file in which the device list is to be saved. ● Print device list (Page 47) The device list is sent to the selected printer. ● Deleting the device list (Page 48) The displayed device list is emptied. Application example: Clearing the device list before reading in device descriptions again. ● Exit (Page 48) Closes the Device Integration Manager. View ● Split device list window (Page 48) The device list window is split or the split is removed. Catalog ● Complete device information (Page 49) If the software detects that relevant information is missing in a device description during its import, the "Device info incomplete" icon appears in the status column of the device list. If you select an affected device in the device list, you can then complete the device information in a dialog. ● Integrate (Page 50) The device descriptions are integrated into SIMATIC PDM for those devices selected in the device list. Requirement: The check box for the required device is selected in the "Path" column of the device list. ● Creating user-specific device DVD (Page 50) Your own device library is created. Device libraries that were created in this way can be copied, compressed or burned to DVD. These libraries can be read in and integrated with the Device Integration Manager just like the SIMATIC PDM DVD "Device Library …". ● Applying Filter File (Page 51) Select a filter file (previously saved device list) according to which the currently displayed device list is to be filtered. ● Applying a project filter (Page 51) Select a project or multiproject to filter the currently displayed device list for components used in the project. ● Remove Filter File/Project Filter (Page 51) Filtering by means of a filter file or project filter is stopped. ● Messages (Page 52) The "Messages" dialog box opens. Integrating devices into SIMATIC PDM 5.3 Views Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 33

Find (Page 53)

The "Find" dialog window opens. ? ● Help (Page 53) Opens the help for SIMATIC PDM. ● Info (Page 54) The following information is displayed: ● SIMATIC PDM version ● Information about the "Device Integration Manager" component Additional information Use SIMATIC Manager to make the settings for the Device Integration Manager. You can find information on this in the following sections: ● Setting the language: Section Options > "Settings (Page 208)" ● Section Options > SIMATIC PDM > Settings > "Device Integration Manager" tab (Page 213) 5.3.3 Toolbar The toolbar is located below the menu bar and contains a number of icons with which you can quickly perform frequently used menu commands without having to open a menu and select the command. Icons Meanings of the icons used: Icon Menu command Description Read device descriptions from source directory (Page 45) Select the storage location of the device descriptions to be read in. Set the path to the device descriptions or navigate to the location. Read device descriptions from compressed source (Page 45) Select the storage location of the compressed device descriptions to be read in. Set the path and the file name for compressed device descriptions or navigate to the location. Integrate (Page 50) The device descriptions are integrated into SIMATIC PDM for those devices selected in the device list. Print device list (Page 47) The device list is sent to the selected printer. Deleting the device list (Page 48) The displayed device list is emptied. Application example: Clearing the device list before reading in device descriptions again. List of integrated device descriptions (Page 46) The device descriptions integrated in the PC are read in to the device list. Integrating devices into SIMATIC PDM 5.3 Views Help for SIMATIC PDM (V8.2) 34 Operating Manual, 02/2014, A5E33203676-AA

List of device descriptions

used (Page 46) The device descriptions used in the STEP 7 project are displayed. Creating user-specific device DVD (Page 50) Your own device library is created. Save device list (Page 47) The displayed information of the current device list is saved. Specify the storage location and file name for the file in which you want the device list to be saved. Applying Filter File (Page 51) Select a filter file (previously saved device list) according to which the currently displayed device list is to be filtered. Applying a project filter (Page 51) Select a project or multiproject to filter the device list for components used in the project. Split device list window (Page 48) The device list window is split or the split is removed once again. Messages (Page 52) The "Messages" dialog box opens. Using the Find function (Page 53) The displayed device list is searched. Open the "Find" dialog box. Enter a character string and specify the search options. Help (Page 53) The SIMATIC PDM help opens. 5.3.4 Device list The device list in the "Device Integration Manager" dialog window contains tabular information on device descriptions and devices that can be interpreted by SIMATIC PDM with a device description. Columns Column Description Path Tree structure - The devices with device description are displayed in a hierarchical structure (catalog path). Flat structure - The devices with device description are displayed without a hierarchical structure. The devices are displayed in a hierarchical structure when you click the "Path" column header for sorting. The devices are displayed in a flat structure when you click the header of any other column (except "Path"). ● Select the check boxes for the devices whose device descriptions are to be integrated. Communication Folder for device classes (actuator/sensor etc.) Manufacturer Device type, Component, Device version, Variant Device name Device name Manufacturer Manufacturer Integrating devices into SIMATIC PDM 5.3 Views Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 35

Communication type for the connection to the field device

Device class Catalog position (object name) New version Version of the device description which was read in from a device description library Integrated version EDD source version Integrated on Installation date of the installed EDD Description Attribute from device file Type ID ID of the device type GSD file Names of the GSD files New DD revision Revision of the device description file of the imported device package Integrated DD revision Revision of the device description file of the integrated device package New device revision Device revision of the device with which the imported device package is compatible. Integrated device revision Device revision of the device with which the integrated device package is compatible. Device library Version number of the device DVD from which the device package was imported during integration If the device package was supplied as a single package, this column is empty. Additional information may be displayed. ● You can select the columns to be displayed in the SIMATIC Manager using the following menu command: Options > SIMATIC PDM > Settings... . ● You will find additional information on this topic in section "Device Integration Manager" tab (Page 213). Status icons of the device description Meaning of icons before the status of the device description integration Icon Meaning Not (yet) integrated Device info incomplete An identical or newer device description is integrated. The device description is in the process of being integrated. The device description has been integrated successfully. The device description is used in the project but neither read in nor integrated. Error; Observe the error details in the message window. Warning; Observe the warning details in the message window. Integrating devices into SIMATIC PDM 5.3 Views Help for SIMATIC PDM (V8.2) 36 Operating Manual, 02/2014, A5E33203676-AA

Meaning of icons after the device descriptions have been read in and before they have been

integrated Icon Meaning The device description has been read in without any errors but has not yet been integrated. The device information is incomplete in the imported device description. The device description cannot be integrated correctly. You can find information on correcting this in the section "Completing a device description (Page 41)". An identical or newer version of the device description is integrated. The device description is in the process of being integrated. The device description has been integrated successfully. Errors occurred while reading in the device description. The device description cannot be integrated. For details regarding the error messages, see the message window. Warnings generated. The device description has been read in and can be integrated. Meaning of the icons after integration of the device description Icon Meaning The device description has not been integrated because the user did not select it for integration. The device description was not integrated because an identical or a newer version was already installed. The device description has been successfully integrated without errors. The device description has been successfully integrated without errors. Warnings occurred during the semantic check. The device description has been successfully integrated without errors. Errors occurred during the semantic check. An attempt was made to integrate the device description. The device description could not be integrated due to an error. ● Error messages: For details, please refer to the message window. ● Potential cause: Device information incomplete during integration. The device description has been integrated. The warnings indicate potential inconsistencies. Sorting You can sort the contents of the table. Click on the cell in the header of the column based on which the contents should be sorted. Clicking on this cell again changes the sorting direction (ascending/descending). Integrating devices into SIMATIC PDM 5.3 Views Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 37

The status bar is located at the bottom of the main window. It displays the number of read in

or integrated device descriptions. 5.3.6 Source folder The Source folder box is located underneath the toolbar. You use this box to select the path in which the device descriptions are located. The device list is created based on the device descriptions. The source can be: Icon Meaning Folder Compressed file (*.zip) Device description file (*.xml) The Source folder box gives you the option to display the history of the directories so far. Click the drop-down list icon on the right side of the box to display the last ten sources. Changing the source folder Procedure 1. Click the "Find folder" icon. The "Change source folder" dialog box opens. 2. Navigate to the required directory in the file system. 3. Click "OK". Alternatively, you can enter the path in the text box. All compressed files included in the selected source directory are searched for the device descriptions. Compressed files within a compressed file are also taken into consideration. 5.3.7 Applying a filter The "Filter" box is located underneath the "Source folder" box. You can filter for up to three strings of your choice (filters 1, 2 and 3) simultaneously. When the filter is applied, all devices that include all specified strings in their device description are displayed. A distinction is not made between uppercase and lowercase letters. Integrating devices into SIMATIC PDM 5.3 Views Help for SIMATIC PDM (V8.2) 38 Operating Manual, 02/2014, A5E33203676-AA

1. Click in the text box "Filter 1", "Filter 2" or "Filter 3".

2. Enter the required search term. 3. Confirm your entry with the "Enter" key. The device list is searched for the search terms and updated. Each input box gives you the option to display the history of the search terms so far. ● Click the drop-down list icon to the right of the text box to display the history. ● To disable individual filters, click on the of the respective filter. Note The filter (text boxes, filter files, project filter) does not only affect the display. The selections of all devices excluded by the filter are removed and no longer set when the filter is disabled. See also Applying a project filter (Page 51) Remove Filter File/Project Filter (Page 51) Applying Filter File (Page 51) 5.3.8 Filter file/Project filter The "Filter file/Project filter" box is located underneath the "Source folder" box. It is only displayed when you use a filter file or the project filter. The devices that match the data of the filter file or are contained in the project file are displayed when the filter is applied. Applying a filter The procedure for applying a filter file or a project filter is described under Filter file (Page 51) or Project filter (Page 51). See also Remove Filter File/Project Filter (Page 51) Integrating devices into SIMATIC PDM 5.3 Views Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 39

Working with the Device Integration Manager

5.4.1 Integrating device descriptions The Device Integration Manager is the SIMATIC PDM function for integrating device descriptions. Device descriptions of the "Device Library" DVD Make sure the device descriptions are always integrated in SIMATIC PDM from the "Device Library" DVD provided with your version of SIMATIC PDM. Changes in the device descriptions and the catalog structure may exist between the different versions. Note FOUNDATION Fieldbus The SIMATIC PDM option "FOUNDATION Fieldbus" must be installed to integrate device descriptions for devices on FOUNDATION Fieldbus. You can find information on this in section "Installing SIMATIC PDM (Page 23)" Upgrading SIMATIC PDM Note Checking for all device types used in the project After integrating the device descriptions, you need to check the assignment of the device description (by opening the parameter assignment interface once). Procedure 1. Close all SIMATIC programs that are open on the PDM PC. 2. Go to the Windows Start menu and select the menu command SIMATIC PDM > Device Integration Manager under the Siemens SIMATIC programs. You must accept the license agreement to be able to use the Device Integration Manager . 3. Select the File > Read device descriptions from source directory... or File > Read device descriptions from compressed source... menu command. 4. Navigate to the folder with the device descriptions in the tree structure. Note "Device Library" DVD The "Device Library" DVD is supplied with SIMATIC PDM. Select the drive containing the DVD. Integrating devices into SIMATIC PDM 5.4 Working with the Device Integration Manager Help for SIMATIC PDM (V8.2) 40 Operating Manual, 02/2014, A5E33203676-AA

5. Click the "OK" button.

The device descriptions found are displayed in the "Devices" list. You can find additional information on this in the section "Device list (Page 35)". 6. Select the check boxes for the devices whose device descriptions are to be integrated. The check box is automatically selected for devices that have not been integrated or have been integrated with an older version. You can work with a split device list window (Page 48). 7. Select the Catalog > Integration... menu command. The device descriptions are transferred to the PC. Note During the device description integration Do not open any SIMATIC programs until the device description integration has completed. Completing the information for a device description If information is missing from a device description, e.g., regarding the classification, you can add this information yourself. You can find information on this in the section "Completing a device description (Page 41)". Additional information ● Section "Delivery contents (Page 22)" ● Section "Messages (Page 44)" ● Section "Checking the device integration (Page 74)" ● Section "Replacing devices (Page 106)" 5.4.2 Completing a device description If the software detects that information is missing in a device description during its import, the "Device info incomplete" icon appears in the status column of the device list. Recommendation: Each device description marked in this way should be completed before it is integrated in SIMATIC PDM. Note Completing device information at a later date If you need to complete any device information at a later date then please follow the procedure below. Integrating devices into SIMATIC PDM 5.4 Working with the Device Integration Manager Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 41

1. Select an incomplete device description and then select the Complete device

information... command in the shortcut menu. 2. Complete the device description. 3. Click "OK". Note Saving the changes ● If the device description is located on a read-only medium, changes cannot be made. In this case, copy the device description to a medium that is not write-protected and start the process again. ● The changes will remain available in the Device Integration Manager until the dialog box is closed. When you click the "OK" button, the changes are applied to the device description. 4. Click "Integrate". The integration of the device description is performed. Additional information You can find information on the device list entries in the section "Device list (Page 35)". 5.4.3 Creating your own device library using the project filter Introduction You use the following procedure to create your own device library using the project filter. Project filter Information on the project filter and its application is available in the section "Applying a project filter (Page 51)". Procedure 1. Read in the device descriptions of a standard library. 2. Apply a project filter. 3. Select the Catalog > Creating user-specific device DVD... menu command. 4. Enter the destination path in the "Create own device library... " dialog box. 5. Enter the device library name or the version identification of the device library. Integrating devices into SIMATIC PDM 5.4 Working with the Device Integration Manager Help for SIMATIC PDM (V8.2) 42 Operating Manual, 02/2014, A5E33203676-AA

Devices without help files

If you are using a device without help files, you can integrate the help files at a later time. To do this, answer the "Missing Help Files" dialog box with "Yes". Additional information Section "Integrating device descriptions (Page 40)" See also Basis for using intelligent field devices (Page 12) 5.4.4 Creating your own device library from a collection of device descriptions You use the following procedure to create your own device library from a collection of device descriptions. Collection of device descriptions You can find information about the availability of device descriptions and their application in the section "Basis for using intelligent field devices (Page 12)". Procedure 1. Read in the device descriptions of a standard library. 2. Select the check box for the device descriptions that you need in your own device library. 3. Select the Catalog > Creating user-specific device DVD... menu command. 4. Enter the destination path in the "Create own device library... " dialog box. 5. Enter the device library name or the version identification of the device library. Note Devices without help files If you are using a device without help files, you can integrate the help files at a later time. To do this, answer the "Missing Help Files" dialog box with "Yes". Additional information Section "Integrating device descriptions (Page 40)" Integrating devices into SIMATIC PDM 5.4 Working with the Device Integration Manager Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 43

Removing device descriptions

Shortcut menu If you select objects in the list of integrated device descriptions, you can use the shortcut menu to remove the device description: Removing integrated device descriptions Delete the selected objects from the list of integrated device descriptions via this menu command. The selected objects are also deleted from the catalog. 5.4.6 Update/upgrade of device descriptions (EDD update) Procedure 1. Check the version of the integrated device descriptions. You can find information on this in the section "Device list (Page 35)". 2. Read in the new device descriptions and compare the new version with the integrated version. You can find information on this in the section "Read device descriptions from source directory (Page 45)". 3. Select the required device descriptions and integrate the device descriptions. The check box is automatically selected for devices that have not been integrated or have been integrated with an older version. Information on this is available in the section "Integrating device descriptions (Page 40)". See also Download to device (Page 200) 5.4.7 Messages Message log If errors occur during the actions or in the application of the Device Integration Manager, they are shown in the message log. The message log opens automatically when a warning or an error has occurred, but it can also be opened manually from any node in the device list. In this case, all messages of the nodes under this in the hierarchical order are displayed. Additional information Section "Message log (Page 138)" Integrating devices into SIMATIC PDM 5.4 Working with the Device Integration Manager Help for SIMATIC PDM (V8.2) 44 Operating Manual, 02/2014, A5E33203676-AA

Menus and dialog boxes

5.5.1 File 5.5.1.1 Read device descriptions from source directory Before devices can be configured in SIMATIC PDM, the associated device description files need to be read in using the Device Integration Manager. Requirement The storage paths of the device description files can be accessed. Procedure 1. Select the menu command File > Read device description files from source directory .... In the tree structure, navigate to the storage path where the device description files are saved. 2. Click "OK". The device description files are read in. Note If the compressed file is password-protected, a dialog appears for entering a password. Shortcut menu If you select objects in the list of read in device descriptions, you will find the following via the object-dependent shortcut menu commands below: ● Messages (Page 44) Open the message log via this menu command. ● Complete device information (Page 49) Open the "Complete device information..." dialog via this menu command. 5.5.1.2 Read device descriptions from compressed source Introduction Before devices can be configured in SIMATIC PDM, the associated device description files need to be read in using the Device Integration Manager. Requirement The storage paths of the device description files can be accessed. Integrating devices into SIMATIC PDM 5.5 Menus and dialog boxes Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 45

1. Select the File > Read device description files from compressed source ... menu command.

2. In the tree structure, navigate to the storage path of the device description files. 3. Click "OK". The device description files are read in. Note If the compressed file is password-protected, a dialog appears for entering a password. Shortcut menu If you select objects in the list of read in device descriptions, you will find the following object- dependent shortcut menu commands: ● Messages (Page 44) You use this menu command to open the message log. ● Complete device information (Page 49) You use this menu command to open the "Complete device information..." dialog. 5.5.1.3 List of integrated device descriptions Displaying the device list Displays the devices for which a device description file is saved on the PC. Shortcut menu If you select objects in the list of integrated device descriptions, you will find the following object- dependent shortcut menu commands: ● Messages (Page 52) You use this menu command to open the message log. ● Remove integrated device description(s) (Page 44) You use this menu command to delete selected objects from the list of integrated device descriptions. See also Complete device information (Page 49) 5.5.1.4 List of device descriptions used Displaying the device list Display of the devices used in the project. Integrating devices into SIMATIC PDM 5.5 Menus and dialog boxes Help for SIMATIC PDM (V8.2) 46 Operating Manual, 02/2014, A5E33203676-AA

The status column (Page 35) indicates whether or not the corresponding device description is

integrated on the computer. If you select a STEP 7 multiproject, all projects are always displayed, even when only a subproject is selected in the dialog box. Shortcut menu If you select objects in the list of integrated device descriptions, you will find the following object- dependent shortcut menu commands: ● Messages (Page 52) You use this menu command to open the message log. ● Remove integrated device description(s) (Page 44) You use this menu command to delete selected objects from the list of integrated device descriptions. See also Complete device information (Page 49) 5.5.1.5 Save device list Saving the device list Specify the storage location and file name for the file in which you want the device list to be saved. 5.5.1.6 Print device list You can print the device list that is currently being displayed. Setting the printer options Note ● The printer options depend on your computer's operating system and on the printer being used. ● The file is sent to the default printer. ● If the printout has more than one page, two periods are printed after the page number in the bottom right corner of the page. The last page does not have these periods, indicating no more pages are to follow. Integrating devices into SIMATIC PDM 5.5 Menus and dialog boxes Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 47

1. Select the menu command File > Print device list or click the "Print" button.

The "Print" dialog box opens. 2. Select the required options. 3. Click "OK". 5.5.1.7 Deleting the device list Clearing the displayed device list. Example of application Clearing the device list before reading in device descriptions again. 5.5.1.8 Exit Exits the "Device Integration Manager". 5.5.2 View 5.5.2.1 Split device list window The device list window is split or the split is removed. When you select the menu command, the device list window is cut in half vertically. The right half shows an additional device list window with the same structure. This window includes all devices selected in the left device list window (check boxes are selected). Note The line selected with the mouse is displayed with a blue background in the active window. In the inactive window, the line is displayed with a gray background. The check boxes in the left device list window are visible but cannot be operated. You can move the dividing line between the two device list windows with the mouse. The buttons for adding or removing selected individual devices or sub-trees are located between the two windows. The selection of devices in the device list window is used for • Integrating and • Creating your own device library. With a device list window that is not split, a selection can be made by setting the check boxes in the line of the device. Integrating devices into SIMATIC PDM 5.5 Menus and dialog boxes Help for SIMATIC PDM (V8.2) 48 Operating Manual, 02/2014, A5E33203676-AA

By selecting a line in the left device list window and clicking the

button, you add individual devices or sub-trees to the right device list window. By selecting a line in the right device list window and clicking the button, you remove the individual devices or sub-trees added previously from the right device list window. Keyboard operation Use the "SHIFT + >" and "SHIFT + <" shortcuts to add or remove the selected devices to and from the right window. Rules for working with split device list windows When a filter is used, it acts on both device list windows. Sorting can take place independently in each window. Searches are only conducted in the active window with the selected line having a blue background. An export only includes the contents of the left window (with selection information). Only one device list window is displayed after the Device Integration Manager is restarted. Note You cannot split the device list window when the list of integrated or used devices is displayed. 5.5.3 Catalog 5.5.3.1 Complete device information Modifying the information in a device description file The table below shows the information that can be completed in the "Device Integration Manager" dialog box using the "Complete device information" function. Column Explanation Device name You can modify the device name in this input box. Name of the device version You can modify the version of the device description in this input field. Manufacturer Manufacturer of the field device Type ID Identifier for a device type in hexadecimal format You can find information on this in IEC 61804-3. Device revision Identifier for a device revision Communication Communication type for the connection to the field device Integrating devices into SIMATIC PDM 5.5 Menus and dialog boxes Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 49

Class of the device - name of the object (e.g., SENSOR - FLOW -

ULTRASONIC) DD revision Version of the device description file You can find information on this in IEC 61804-3. EDD Name of the device version You can find information on this in IEC 61804-3. 5.5.3.2 Integrate Use the menu command Catalog > Integrate to integrate the device description files of the devices into the device catalog of SIMATIC PDM for those devices with selected check boxes in the "Path" column of the device list. Compiling device description files for SIMATIC PDM You can find information about the possible settings in the description of the PDM setting in the section ""Device Integration Manager" tab (Page 213)". Remove integrated device description(s) Section "List of integrated device descriptions (Page 46)" 5.5.3.3 User-specific device DVD Creating user-specific device DVD You can use the Catalog > Creating user-specific device DVD... menu command to create your own device library. You can copy created device libraries, save them as compressed archive or burn them on DVD and read in and integrate them with the Device Integration Manager just like the SIMATIC PDM DVD "Device Library …". Additional information Information on creating a device library from a collection of device descriptions is available here (Page 43). Information on creating a device library using a project filter is available here (Page 42). "Creating user-specific device DVD" dialog Procedure 1. Select the Catalog > Creating user-specific device DVD... menu command. The "Create own device library ..." dialog box opens. 2. Enter the destination path, the name and a version identification of the device library. 3. Click "OK". Integrating devices into SIMATIC PDM 5.5 Menus and dialog boxes Help for SIMATIC PDM (V8.2) 50 Operating Manual, 02/2014, A5E33203676-AA

Applying Filter File

You can use the Catalog > Applying Filter File... menu command to apply predefined filter files (device lists in XML format saved in the Device Integration Manager beforehand) to the device library. The "Filter file" box is displayed underneath the "Source folder" box if a filter file is loaded. "Apply Filter File..." dialog box Procedure 1. Select the Catalog > Applying Filter File... menu command. The "Applying Filter File..." dialog box opens. 2. Select a file with an exported device list. 3. Click "OK". The currently displayed device list is filtered as follows: • Only devices that are read in and are included in the filter file are displayed. • Only devices that are selected in the filter file can be selected for integration. Remove Filter File/Project Filter The Catalog > Remove Filter File/Project Filter menu command is used to stop the application of the filter file or a project filter. The complete device list is displayed once again when you revoke the filter. 5.5.3.5 Project filter Applying a project filter You can use the Catalog > Apply Project Filter… menu command to select a STEP 7 project or STEP 7 multiproject to filter the device list for the components used in the project. The "Project filter" box is displayed underneath the "Source folder" box if a project is loaded. By combining the "Create own device library" and "Apply Project Filter" functions, you can create a device DVD that is perfectly adapted to your project. Integrating devices into SIMATIC PDM 5.5 Menus and dialog boxes Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 51

If you select a STEP 7 multiproject, all projects are always selected, even when only a

subproject is selected in the dialog box. Note Object status Make sure that the status of each device contained in the project file is also integrated in the device library before you apply the project filter. You can determine this by the status icon in the "Icon" column of the device list. You can find a list of the icons under Device list (Page 35). Additional information Information on creating a device library using a project filter is available here (Page 42). "Apply project filter..." dialog box Requirement A device list has been read in. Applying a project filter Procedure 1. Click the "Apply Project Filter..." icon in the menu bar. The "Open Project" dialog box opens. 2. Select the required project in the "User project" tab. If you want to open a multiproject, select the "Multiproject" tab. 3. If the required project file is located on an external source, click the "Browse" button and navigate to the required path. 4. Confirm your entry by pressing "Enter". The device list is searched and updated. To revoke the filter, click the button. Remove Filter File/Project Filter The Catalog > Remove Filter File/Project Filter menu command is used to stop the application of the filter file or a project filter. The complete device list is displayed once again when you revoke the filter. 5.5.3.6 Messages Opens the "Messages" dialog box. Integrating devices into SIMATIC PDM 5.5 Menus and dialog boxes Help for SIMATIC PDM (V8.2) 52 Operating Manual, 02/2014, A5E33203676-AA

Section "Message log (Page 138)"

5.5.3.7 Find Using the Find function You can use the Catalog > Find menu command to find device description files. "Find" dialog box Procedure 1. Select the menu command Catalog > Find. The "Find" dialog box opens. 2. Enter a string and define search options. 3. Click "Find". Settings in the "Find" dialog box ● Entry field with drop-down list You can enter any string. You can search for this string. ● Check boxes – Match case The writing style of the string entered for an object in the device list is observed. – Match entire cell contents The entire string must match for an object in the device list. – Search up If this option is enabled, the search begins at the selected point and continues until the start of the device list. If this option is disabled, the search begins at the selected point and continues until the end of the device list. ● "Find" button The system searches through the displayed device list. 5.5.4 ? (Help) 5.5.4.1 Help This menu command displays the Help on SIMATIC PDM. Integrating devices into SIMATIC PDM 5.5 Menus and dialog boxes Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 53

You can navigate to different help topics from the Table of Contents. The "Index" and "Find"

functions enable you to display information on specific terms. 5.5.4.2 Info This menu command displays information about the version and the copyright. Integrating devices into SIMATIC PDM 5.5 Menus and dialog boxes Help for SIMATIC PDM (V8.2) 54 Operating Manual, 02/2014, A5E33203676-AA

PDM objects are displayed in the following views in SIMATIC Manager:

● Process Device Plant View The process device plant view provides an overview of all configured devices in all configured networks. ● Process Device Network View The plant topology is reproduced in the process device network view. The depicted objects are links to the objects in the plant view. ● PDM objects can be configured with HW Config. Open the SIMATIC PDM shortcut menu to assign parameters. ● The network links to the PDM objects are also listed in NetPro. Working with SIMATIC PDM License keys are required to use SIMATIC PDM. You will find information about this in the pdmbase-readme file. Recommendation: Before you assign parameters to a field device with SIMATIC PDM, check whether you can reach the required device. Additional information Section "Settings" for the SIMATIC project (Page 71)" 6.2 Views in SIMATIC Manager 6.2.1 Process devices plant view In SIMATIC Manager, you call the process devices plant view using the menu command View > Process devices plant view. The process devices plant view provides an overview of all configured devices in all configured networks. This view is used to obtain a quick overview of the configured devices. You cannot configure new networks in this view. Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 55

Section ""Settings" for the SIMATIC project (Page 71)"

6.2.2 Process devices network view In SIMATIC Manager, you call the process devices network view using the menu command View > Process devices network view. The process devices network view displays the devices in groups according to the network topology. You can configure smaller projects directly in the process devices network view, for example, for end-to-end connections between a PC and a device in the factory. Views 6.2 Views in SIMATIC Manager Help for SIMATIC PDM (V8.2) 56 Operating Manual, 02/2014, A5E33203676-AA

Section ""Settings" for the SIMATIC project (Page 71)"

6.2.3 Open SIMATIC PDM in the Process Devices - Plant View Procedure 1. Select the View > Process devices plant view menu command in SIMATIC Manager. The process devices plant view opens. 2. Select the "Devices" object in the S7 project. All available devices are displayed. 3. Double-click the desired object. The desired object opens in SIMATIC PDM. 6.2.4 Project synchronization HW Config In the course of device configuration in HW Config, an image of the plant structure, including all devices which can be configured using SIMATIC PDM, is transferred from HW Config to the process devices network view. After saving in HW Config, the changes made to the devices are applied in the following views: ● Process devices network view ● Process devices plant view Changes cannot be incorporated into the process devices view if the higher-level objects are linked with HW Config to an existing S7 station. Views 6.2 Views in SIMATIC Manager Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 57

Views in SIMATIC PDM

6.3.1 Main Window "SIMATIC PDM" Introduction The "SIMATIC PDM" main window remains on the screen throughout the work session and is partially or totally covered by other activated dialog windows. The main window is structured as follows: Title bar (Page 59): The title bar shows the project name or the name of the object which was selected before SIMATIC PDM was called. Menu bar (Page 59): The menu bar can be used to call SIMATIC PDM functions and manufacturer- specific device functions. Toolbar (Page 60): The toolbar enables certain menu commands to be accessed quickly. Structure view (Page 60): The objects displayed depend on the object which was selected before SIMATIC PDM was started. Parameter table (Page 61): The parameters for the object selected in the structure view are displayed in a table. Status bar (Page 64): Contains information on processes currently being performed. Views 6.3 Views in SIMATIC PDM Help for SIMATIC PDM (V8.2) 58 Operating Manual, 02/2014, A5E33203676-AA

The title bar shows the name of the object which was selected before SIMATIC PDM was

called. 6.3.3 Menu bar Structure Below is an overview of the SIMATIC PDM menus. Menu Submenu in parameter assignment mode File ● Save (Page 155) ● Exporting (Page 200) ● Importing (Page 200) ● Print (Page 161) ● Exit (Page 162) Device ● Download to device (Page 163) ● Upload to PG/PC (Page 165) ● Assign address and TAG (Page 171) ● Value comparison (Page 168) ● Object properties (Page 172) ● Calibration log (Page 176) ● Change log (Page 184) View ● Process variables (Page 188) ● Start LifeList (Page 127) ● Trends (Page 189) (depends on device) Diagnostics ● Update diagnostics (Page 191) Help ● Contents (Page 193) ● Help for device parameters (Page 193) ● Info (Page 193) ● Find (Page 194) ● Document Manager (Page 194) ● Device manual (depends on device) Views 6.3 Views in SIMATIC PDM Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 59

The toolbar is located below the menu bar and contains a number of icons with which you can

quickly perform frequently used menu commands without having to open a menu and select the command. SIMATIC PDM mode Icons Parameter assignment mode Icons The icons are linked to the following commands: Parameter assignment mode Menu command Save (Page 155) Print (Page 161) Download to device (Page 200) Upload to PG/PC (Page 201) Value comparison (Page 168) Change log (Page 184) Process variables / Measured value display (depends on device) (Page 188) Update diagnostics (Page 191) Start LifeList (Page 127) Find (Page 194) Contents (Page 193) 6.3.5 Structure view The left-hand section of the main window in the structure view contains a tree structure. The objects displayed depend on the object which was selected before SIMATIC PDM was started. ● If a single field device was selected, it will be displayed in the structure view. You can find information on this in the section "Stand-alone device view (Page 65)". ● If a network or gateway (e.g., DP/PA-Link) was selected, the tree structure is displayed with the associated devices in the structure view. You can find information on this in the section "Multiple devices view (Page 66)". Views 6.3 Views in SIMATIC PDM Help for SIMATIC PDM (V8.2) 60 Operating Manual, 02/2014, A5E33203676-AA

You will see the following status icons in front of the objects in the tree view:

Icon Meaning The device has been loaded. At least one parameter of the object has been changed. The object is already open at another location (window or computer). The object is locked for editing in the current view. The object is already open at another location (window or computer). Another user is making changes to the object. At least one parameter of the object is defective. Display The following are displayed in the structure view: ● Objects with associated parameter groups ● Any available lower-level objects The selected parameter group is displayed on a blue background. The parameter table shows the parameters of the selected parameter group. Objects that contain lower-level objects can be identified by the check boxes next to the object icon: ● Check box "+" ● Check box "-" Note Generally speaking, the table is only opened down to the structure view. Move the parameter table in order to view all the general information for a device. 6.3.6 Parameter table The right pane of the main window is filled by the parameter table. The parameter table shows a device's parameters in the order in which they are listed in the structure view. Unlike in the structure tree, no hierarchy is displayed here. Device parameters The parameters which can be edited depend on the device in question. Fields with a gray background cannot be edited. Views 6.3 Views in SIMATIC PDM Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 61

Refer to the manufacturer device description for information on how to set the device

parameters. Display of the parameter table The following columns are displayed in the parameter table: ● Parameter (Page 62) ● Value (Page 62) ● Unit (Page 63) ● Status (Page 63) Each parameter group starts with a header with the name of the group on a gray background. The indented header text indicates the classification level of the header. The parameter lines are positioned underneath the header. Operator input Any entries and changes made must be loaded to the devices in order for them to take effect. If you click an object in the structure view, the associated parameters are displayed in the parameter table. Additional information ● Section "Display in the views (Page 64)" 6.3.6.1 "Parameter" column of the parameter table The names of the individual parameters are listed in the "Parameter" column. 6.3.6.2 "Value" column of the parameter table This column displays the value of the parameter whose name is in the "Name" (Page 62) column. This can be a numerical value, a physical unit, a status, or a designation. The "Value" box can only be edited if it has a white background. A box with a gray background indicates that the parameter is read-only and cannot be modified or written. ● Right-click on the value to display a list of possible value settings for selection, provided that these value settings are specified in the device description. ● Enter a new value here or select a new setting from the drop-down list box. Views 6.3 Views in SIMATIC PDM Help for SIMATIC PDM (V8.2) 62 Operating Manual, 02/2014, A5E33203676-AA

Right-click inside the parameter table to open one of the following fields:

● An information box is shown for static fields if the cursor is located over a parameter in the "Parameter" column. Information is displayed to explain the meaning of the field or to explain the associated entry in the "Value" column. ● Selection of values from drop-down lists The drop-down lists open when you select a corresponding value with the cursor and click on it. Select the correct setting for your plant- and device-specific conditions. ● Shortcut menu for input boxes Menu command Explanations/operating instructions Minimum value ... Displays the minimum permitted value of the parameter. *) **) Maximum value ... Displays the maximum permitted value of the parameter. *) **) Default value ... Displays the default value of the parameter. *) **) *) Click the value to transfer it to the parameter table. **) There can be several minimum, maximum and default values. 6.3.6.3 "Unit" column of the parameter table The "Unit" column displays the engineering unit of the numerical value present in the "Value" (Page 62) column. 6.3.6.4 "Status" column of the parameter table The "Status" column displays the status of the parameter whose name is in the "Name" (Page 62) column. The table below shows the icons that can be displayed here: Icon Meaning Action that can trigger the status - empty - Value (Page 62) corresponds to the offline data storage system. Save Initialization running or status "OK". Value was never changed. Open new PDM object The parameter has been changed by means of operator input, import, or internal methods. Value was changed by user. ● Edit ● Dialogs The parameter could not be converted. Value could not be converted following a change in the unit. Edit Views 6.3 Views in SIMATIC PDM Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 63

Action that can trigger the

status A parameter's value is defective. An illegal value was detected the validity check (e.g., value too high or too low) Validity check of value The parameter has been successfully loaded. There is no difference between the loaded and the configured parameter. ● Download to device ● Upload to PG/PC The parameter cannot be loaded, as a communication error is present. ● Error message when downloading to the device ● Error message when uploading to PG/PC ● Download to device ● Upload to PG/PC 6.3.7 Status bar The status bar is located at the bottom of the main window. Display The following information is provided in the status bar: ● User that is currently using SIMATIC PDM ● PDM object for which information is currently being displayed in the parameter list ● Diagnostics activated / deactivated ● Identity check activated / deactivated ● Processing status ● Connection status for the object currently selected in the tree structure 6.3.8 Display 6.3.8.1 Display in the views Operating principle You can open SIMATIC PDM for a device from SIMATIC Manager or HW Config. After you open SIMATIC PDM, the table displays the values saved in the project. These values are projected values and default values of the object, which was selected before SIMATIC PDM was started. All objects for which parameters can be assigned are displayed in the structure view, including the lower-level objects. Only the parameter table of the root object is initially displayed and can be edited (fields on white background). Views 6.3 Views in SIMATIC PDM Help for SIMATIC PDM (V8.2) 64 Operating Manual, 02/2014, A5E33203676-AA

Select an object in the structure view; its parameters are then shown in the parameter table,

where they can be edited. ● If an object has already been opened by a different user, a message is displayed that identifies the user who opened the object and the PC from which the object was opened. All fields of the parameter table then have a gray background and cannot be modified. Note Changes made to an object opened in SIMATIC PDM only take effect when you select the menu command File > Save. The displays in the status bar and title bar depend on the object you have currently selected. Setting options for SIMATIC PDM You can find information on this in the section "Settings for SIMATIC PDM (Page 210)". 6.3.8.2 Stand-alone device view SIMATIC PDM is opened in the stand-alone device view if a device was selected before SIMATIC PDM was started. The device represents the base of the tree in the structure view. The main window is structured as follows: Title bar Menu bar Toolbar Parameter table (on the right in the main window) Status bar Views 6.3 Views in SIMATIC PDM Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 65

Section "Main Window "SIMATIC PDM" (Page 58)"

6.3.8.3 Multiple devices view SIMATIC PDM is opened in the multiple device view if an object with lower-level objects was selected before SIMATIC PDM was started, e.g. an ET 200 station with connected field devices. The object represents the base of the tree in the structure view. The main window is structured as follows: Title bar Menu bar Toolbar Parameter table (on the right in the main window) Status bar Display When the multiple device view is opened, only the parameter table of the root object is displayed at first. You can edit all the displayed objects and their lower-level objects without opening SIMATIC PDM again. Additional information ● Section "Main Window "SIMATIC PDM" (Page 58)" 6.3.9 Keyboard operation Key shortcuts The tables below list the key shortcuts. Views 6.3 Views in SIMATIC PDM Help for SIMATIC PDM (V8.2) 66 Operating Manual, 02/2014, A5E33203676-AA

Selecting menus via keys

Key shortcut Function Save (File menu) (Page 155) Print... (File menu) (Page 161) For the menu which contains the underscored letter X Underscored letter in the menu command Assigned menu command Key operation in dialog boxes Key shortcut Function To the next input field, from left to right and from top to bottom Arrow keys Selected in the drop-down list Spacebar Selects an object or cancels a selection Key operation in help programs Key shortcut Function Closes the help window, return to the tool window Selecting menu commands using shortcut keys You can execute many menu commands by pressing the associated ALT key shortcut. Press the following keys in succession: 1. key 2. The underscored letter of the required menu (e.g. , for the File menu - if the menu bar contains a File command). The menu opens. 3. Letter that is underlined in the desired menu command. The submenus of the corresponding menu commands will be opened in the next steps. Repeat these actions until you have selected the entire menu command by typing in the relevant letters. You trigger the menu command as soon as you have entered the last letter of the shortcut keys. Example Menu Key shortcut File + Help + Views 6.3 Views in SIMATIC PDM Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 67

Before you can work with SIMATIC PDM, a project containing at least one PDM object must

have been created in SIMATIC Manager. In the following, the term "PDM object" is used to refer to those objects that can be configured, have parameters assigned, or be diagnosed with SIMATIC PDM. PDM objects include: ● Field devices ● Remote I/O stations (with/without modules or field devices) ● Networks containing field devices Information about the creation process ● For information on creating a project, refer to the PCS 7/STEP 7 help. ● For information on creating PDM objects, please refer to the section "Inserting devices (Page 77)". Requirements for working with SIMATIC PDM ● SIMATIC PDM is installed. ● The necessary license keys are available. ● The device descriptions have been integrated. ● For online functions to work there must be a connection to the corresponding network. You can find additional information on this in the section "Establishing connections to field devices (Page 13)". Calling SIMATIC PDM Where Requirement Function SIMATIC Manager ● Process device network view ● Process device plant view Project containing PDM object has been created. Select object Edit > Open object HW Config Device is created. Double-click device Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 69

Scope of functions

● Configuration and parameter assignment – Integrating field devices into plants and networks – Making project engineering settings for and configuring connections – Making project engineering settings for and configuring devices ● Mini control and monitoring system for field devices – Controlling and monitoring field devices ● Diagnostics – Performing diagnostics on field device functions – Performing diagnostics on networks – Evaluating logs Hardware configurations Integration into a SIMATIC project enables you to create SIMATIC stations and field devices in HW Config. You can open SIMATIC PDM directly on the networks and subordinate field devices listed below: ● PROFIBUS DP ● PROFIBUS PA ● PROFINET IO ● Ethernet ● HART modem ● FOUNDATION Fieldbus Assigning parameters and loading In the case of offline parameter assignment, data relating to entries and changes made in SIMATIC PDM is saved in the project data. The inputs and changes will only become active after uploading the project data to the device. The option for online parameter assignment depends on the device and must be stored in the device description. Entries and changes made in SIMATIC PDM must be loaded into the project. Functions 7.1 Introduction Help for SIMATIC PDM (V8.2) 70 Operating Manual, 02/2014, A5E33203676-AA

"Settings" for the SIMATIC project

You will find the following views in SIMATIC Manager after the installation of SIMATIC PDM: ● Process device plant view ● Process device network view Project settings The project settings are made in the SIMATIC Manager. These settings apply to the SIMATIC project and SIMATIC PDM. ● Language for the menus and dialog boxes ● Default project view ● Display ● Details in the columns You make the project settings in SIMATIC Manager using the following menu command: Options > Settings... Settings Tab Meaning Language selection "Language" tab Language displayed in the menus and dialog boxes in the SIMATIC Manager and SIMATIC PDM Default project view "View" tab Start view for the SIMATIC Manager; available views for SIMATIC PDM: ● Process device plant view ● Process device network view Details in the columns "Columns" tab Views and object types in the parameter table "Columns" tab On the "Columns" tab, you can select the columns that you want to be displayed in a PDM view. Select an object type in the tree structure. Then go to the "Visible Columns" list and activate the check boxes for the entries you want to be displayed for the selected object type. Object types Functions 7.2 Project editing Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 71

Type 1 in the tree structure

– Process device plant view – Process device network view ● Type 2 in the tree structure – Process device plant view > Devices ● Type 3 – Process device network view > Networks ● Type 4 – Process device network view > Networks > PC ● Type 5 – Process device network view > Networks > Communication network – Process device network view > Networks > Communication network > Object(on all subordinate levels) Visible columns Object type Type 1 Type 2 Type 3 Type 4 Type 5 Object name Standard Standard Standard Standard Standard Picture Name For OS Standard - - - - LID (Location identifier denotes the installation position of a device) - Standard - - - Address - x - Standard Standard Description Standard Standard Standard Standard Standard Message Standard Standard Standard Standard Standard Device status - Standard - - Standard Last communication - Standard - - Standard Text1 x x x x x Text2 x x x x x Text3 x x x x x Device - Standard x x Standard PLT ID* - Standard - - x Manufacturer - Standard - - Standard Serial number - x - - x Installation date - x - - x Hardware version - x - - x Software version - x - - x Article number - x - - x Object status - Standard - - Standard DD revision - x - - x Author x x x x x Functions 7.2 Project editing Help for SIMATIC PDM (V8.2) 72 Operating Manual, 02/2014, A5E33203676-AA

*Process control ID generated internally by PDM for identification of an object for connections

to the Asset Management System (PCS 7 Maintenance Station and PDM Maintenance Station). ● Type 6 – Settings for a multiproject Process device plant view (multiproject) Process device network view (multiproject) Object name Standard Standard Project language Standard Standard UNC path Standard Standard Path to "Computer" Standard Standard Computer Standard Standard Computer after removal Standard Standard Path after removal Standard Standard See also Settings for SIMATIC PDM (Page 210) Menus and dialog boxes for SIMATIC PDM in the SIMATIC Manager (Page 195) 7.2.2 Setting the interface on the computer Use the interface settings of the project (SIMATIC PCS 7 or SIMATIC STEP 7). The following interface types are used in SIMATIC PCS 7 and SIMATIC STEP 7: ● PROFIBUS DP interface ● Ethernet interface ● COM interface Alternative communication channels in the case of redundant S7-400 stations If SIMATIC PDM signals a connection failure due to a fault in the communication channel, an attempt is made to automatically establish a connection using the redundant S7-400 station via an alternative communication channel. Functions 7.2 Project editing Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 73

Plant-wide communication by means of routing

Overview In most automation systems, the programming device can only be operated via the bus cable (subnet) connected directly to the automation system. On larger networked plants you must connect the programming device to different bus cables (subnets) before you can go online to a remote automation system. Routing function The routing function allows you to reach automation systems online across subnet boundaries from a central point (Engineering Station) with the programming device or PC, in order, for example, to download user programs or a hardware configuration or to perform test functions. Requirements The following conditions must be met for S7 routing: ● STEP 7 as of version 5.5 and SIMATIC PDM, i.e., SIMATIC PDM, are integrated. ● The communication-capable modules (CPUs or CPs) which establish gateways between subnets must support "S7 routing". ● All the automation devices or communications partners that can be reached in a plant network are configured and downloaded within an S7 project. ● The SIMATIC S7 station required is networked and can be reached via the network nodes. ● The last communication interface (CPU, CP) supports the "Dataset gateway" function. ● The modules are downloaded together with the configuration information, which contains the current "knowledge" on the complete network configuration of the project. Reason: All the modules involved in the gateway must receive information on which subnets can be reached over which routes (routing tables). ● The programming device or PC to which you want to establish an online connection via a gateway is configured in the network configuration and assigned to your programming device. Additional information SIMATIC documentation; SIMATIC PDM; pdm-readme 7.2.4 Checking the device integration You can check in a project whether the required device descriptions are integrated for all objects to be displayed in SIMATIC PDM. These situations serve as examples for this: Functions 7.2 Project editing Help for SIMATIC PDM (V8.2) 74 Operating Manual, 02/2014, A5E33203676-AA

A project has been copied to the PDM computer.

● Device descriptions have been deleted on the computer. ● A computer has been reinstalled and the device descriptions were not integrated. Requirement SIMATIC PDM is installed. Procedure 1. Open the process devices plant view in SIMATIC Manager. 2. Open the "Devices" folder in the tree view. 3. Check whether devices are there that are labeled as follows: Icon Meaning Note Deactivated No device description is integrated in SIMATIC PDM for the device. 4. If deactivated devices have been found, select the View > Details menu command. 5. Check the information in the "Object name" column. Information in the "Object name" column Meaning Further procedure "TAG" or "Default" A device description from the device catalog has not yet been assigned to the device. Assign the required device description to the device. Section "Device selection (Reassign) (Page 202)" Plant-specific object name The device description that has been assigned to the device cannot be found or is no longer functional (e.g. accidentally deleted). Integrate the required device description. Section "Integrating device descriptions (Page 40)" Additional information ● Section "Overview of Device Icons (Page 124)" ● Section "Replacing devices (Page 106)" ● Section "Completing a device description (Page 41)" ● Section "Cleaning the project (reorganization) (Page 76)" 7.2.5 Print You can print out the parameter list for a device. Functions 7.2 Project editing Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 75

Setting the printer options

Note Note the following: ● The printer options depend on your computer's operating system and on the printer being used. ● The file is sent to the default printer. ● If the printout has more than one page, two periods are printed after the page number in the bottom right corner of the page. The last page does not have these periods, indicating no more pages are to follow. Requirements ● SIMATIC PDM is open. ● In the structure view, an object is selected in the root folder of a device. You can find information on the structure view in the section "Stand-alone device view (Page 65)". Procedure 1. Select the menu command File > Print or click the "Print" button . The "Print" dialog box opens. 2. Select the required options. 3. Click "OK". 7.2.6 Cleaning the project (reorganization) PDM objects can be contained in copied SIMATIC projects. If SIMATIC PDM will no longer be used in the project, you can remove the requirement for TAG licenses in the project using the "Reorganize" function. Note SIMATIC PDM must be closed before you use the "Reorganize" function. The time it takes to perform reorganization depends on the data movement required, and it can be a long time. The function is therefore not carried out automatically (for example, when closing a project). Procedure In SIMATIC Manager, select the menu command File > Reorganize. Functions 7.2 Project editing Help for SIMATIC PDM (V8.2) 76 Operating Manual, 02/2014, A5E33203676-AA

Saving the configuration

Changes that are made with SIMATIC PDM are always stored in the SIMATIC project. Save the SIMATIC project to save the changes. Stop SIMATIC PDM before you save an entire SIMATIC project. Procedure Select the menu command File > Save As in the SIMATIC Manager. Additional information ● STEP 7 Online Help ● PCS 7 Online Help 7.3 Device management 7.3.1 Inserting devices 7.3.1.1 Inserting objects You can use the "Insert New Object" function to perform the following: ● Create networks, including network components ● Insert objects into a configured network: – Insert an individual device or module – Insert multiple devices or modules at the same time Note This function is only available for the following devices: ● PROFIBUS devices ● PROFINET devices ● HART modem devices ● HART devices downstream of a remote I/O Configure FOUNDATION Fieldbus devices in HW Config. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 77

The project is open in the process device network view.

● The PDM folder called "Networks" is available in the tree structure. If the folder structure has not yet been created, select the menu command Insert New Object followed by Networks. Note Licenses for SIMATIC PDM are required for further processing. Without license keys, you can configure a maximum of 4 devices (demo mode). Inserting a network, a header module, modules, and a field device Follow the steps below to insert objects into higher-level objects one after the other. You will find more information on object types that can be inserted in an object in the section ""Insert Object - Assign Device Type" dialog box (Page 79) ". Procedure 1. Select the higher-level object in the tree structure in the window on the left. 2. In the shortcut menu, select the menu command Insert New Object > Object. The "Insert Object - <...>" dialog box opens. 3. Make the relevant settings for the inserted object. You can find information on this in the section ""Insert Object - <...>" dialog box (Page 78)" – "Object name" input box – "
" input box (e.g., PROFIBUS address or PROFINET IP address) – "Number" input box 4. Click the "Assign Device Type" button. The "Insert Object - Assign Device Type" dialog box opens. You can find additional information on this in the section ""Insert Object - Assign Device Type" dialog box (Page 79)". 5. Select the object to be added from the tree structure. 6. Click "OK". The objects are inserted. 7. Correct the assigned addresses if necessary. You can find additional information on this in the section "Setting the bus address in HW Config (Page 83)". Additional information Section "Device selection (Reassign) (Page 202)". 7.3.1.2 "Insert Object - <...>" dialog box Make the settings for inserted objects in the "Insert Object - <...>" dialog box. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 78 Operating Manual, 02/2014, A5E33203676-AA

You must set the following parameters in order to insert objects:

● Object name Specify the name of the inserted object. The entered name is the base name when creating several objects. ●
(e.g., PROFIBUS address or PROFINET IP address) Note This setting cannot be changed when HART devices are added. – Enter the address for the inserted object. – If you wish to create multiple objects, enter the first address of the objects to be inserted. ● Number Note This setting cannot be changed when HART devices are added. Adjust the number of objects to be added when adding several objects. Please note that the value depends on the network being used and other factors. A certain number (n) of objects of one type is created in accordance with these parameters. The object name is generated as follows: – If the number is equal to 1, the address does not appear in the object name that is generated ().
– If the number is greater than 1: PROFIBUS devices and modules Channels of remote I/O
... ...
*: n corresponds to the number of objects to be inserted "Assign Device Type" button The "Insert Object - Assign Device Type" dialog box opens. Assign a specific object type to the object you want to insert in the project. The possible object types are listed in the tree structure. The object types displayed depend on the location at which an object was inserted. 7.3.1.3 "Insert Object - Assign Device Type" dialog box Select the device description file of the desired device in this dialog box. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 79

The devices are structured by the device types in a tree structure.

Note Integrated devices You can only select devices for which a device description file has been integrated via the Device Integration Manager. Object types When assigning objects, select the object type. The following object types can be assigned, depending on the nature of the higher-level object: Higher-level object Object to be inserted PDM "Networks" folder Communications network ● As part of the assignment process, select the communications network via which the PDM objects are to be connected. ● Selection: – PROFIBUS DP network – PROFIBUS link – PROFINET network – MODBUS – Ethernet – HART modem network – HART server – Foundation Fieldbus network Header module ● Selection: – Remote I/O – PROFIBUS Link – PROFIBUS DP device – PROFIBUS PA device – HART device Remote I/O Modules ● Selection: – Module Modules ● Selection: – Module Field device ● HART device "Device identification" Button When you click this button, a connection to the device is established and an attempt is made to read the information from the device. If not all the required information could be read out, only the structures necessary for the device will remain in the tree structure. Make your selection from these structures. Device identification procedure: ● For PA devices: Select the "PROFIBUS PA" folder and then press the "Device identification" button ● For DP devices: Select the "PROFIBUS DP" folder and then press the "Device identification" button Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 80 Operating Manual, 02/2014, A5E33203676-AA

For MODBUS devices:

Select the "MODBUS" folder and press the "Device identification" button ● For HART devices: Select the "HART" folder and then press the "Device identification" button Additional information ● Section "Integrating devices into SIMATIC PDM (Page 31)" 7.3.1.4 Integrating a device in HW Config Below, you will learn how to insert devices in the project using HW Config: ● Inserting a DP device ● Inserting a DP remote I/O system (distributed I/O) ● Inserting a PA device at a DP/PA coupler ● Inserting a PA device at a DP/PA-Link ● Inserting a PA remote I/O system (distributed I/O) ● Inserting a remote I/O system (PROFINET) Requirement PROFIBUS DP master system or PROFINET IO system Options for creating the PROFIBUS DP master system: ● In HW Config: If the DP master system is not displayed, select the menu command Insert > Master system at the required PROFIBUS module. ● In the process device network view: – Open the process device network view in SIMATIC Manager. – Double-click the "Networks" object in the right window to insert a PROFIBUS DP network. Select "Networks" in the left window, and select the menu command Insert New Object > Object in the shortcut menu. – Click the "Assign Device Type" button. The "Insert object - Assign device type" dialog box opens. You can find additional information on this in the section ""Insert Object - Assign Device Type" dialog box (Page 79)". – Select the PROFIBUS DP network from the tree structure. – Click "OK". The PROFIBUS DP network is inserted. Note Representation in HW Config Objects created in the process device network view are not displayed in HW Config. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 81

Inserting a DP device

PROFIBUS devices can be inserted directly into the PROFIBUS DP master system. 1. Select the device you require under "PROFIBUS DP" in the hardware catalog and drag it onto the DP master system. Inserting a DP remote I/O system (distributed I/O) Integration is described based on the example of ET 200iSP . 1. Place the head-end station "IM152-1" you have selected from the hardware catalog under "PROFIBUS DP > ET200iSP" at the DP master system. The slots of the head-end station are displayed in the detail view in the table below the graphic. 2. You can insert the required analog and digital modules in slot 4 and higher. Inserting a PA device at a DP/PA coupler 1. Select a device in the PROFIBUS-PA folder of the hardware catalog. This can be, for example, a SITRANS P pressure transmitter listed under "PROFIBUS-PA > Siemens > Sensors > Pressure > SITRANS P" or a device profile listed under "PROFIBUS- PA > Other". 2. Position it at the PROFIBUS DP master system. You have to select the device for some objects. You can find information on this in the section ""Insert Object - Assign Device Type" dialog box (Page 79)". Note The DP/PA coupler does not need to be configured; you only need to set an appropriate bus transmission rate (for example, 45.45 kbps for the Siemens coupler) for the DP master system. Inserting a PA device at a DP/PA-Link 1. Place the "IM 153-2" you have selected from the hardware catalog under "PROFIBUS DP > DP/PA-Link" at the DP master system. (The IM 153-2 replaces the IM 157, but both types can be used as PROFIBUS-Link ). HW Config creates a PA master system for the DP/PA-Link . 2. Drag-and-drop the PA devices to this PA master system. For certain objects it is necessary to select the device. You can find information on this in the section ""Insert Object - Assign Device Type" dialog box (Page 79)". Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 82 Operating Manual, 02/2014, A5E33203676-AA

Inserting a PA remote I/O system (distributed I/O)

Integration is described based on the Pepperl+Fuchs example. 1. You can find the "RSD-GW-EX1.PA" head-end station in the hardware catalog under "PROFIBUS-PA\REMOTE I/O\PEPPERL+FUCHS GmbH\ P+F I/O System". Place the head-end station on the DP master system (with DP/PA coupler, see above) or on the PA master system (with DP/PA-Link, see above). The slots of the head-end station are displayed in the detail view in the table below the graphic. 2. Place one of the modules listed in the hardware catalog under "PROFIBUS-PA > P+F I/ O SYSTEM > RSD-GW-EX1.PA" in a free slot. Inserting a remote I/O system (PROFINET) The integration is described using ET 200M as an example. 1. Place the head-end station "IM153-4" you have selected from the hardware catalog under "PROFINET IO > I/O > ET200M" at the IO system. 2. The slots of the head-end station are displayed in the detail view in the table below the graphic. You can insert the required analog and digital modules in slot 4 and higher. 7.3.1.5 Setting the bus address in HW Config Make sure the bus addresses of all field devices are entered correctly in HW Config. Bus addresses can only be set for field devices on a PROFIBUS network. Procedure Proceed as follows to edit the settings: 1. Select a field device in HW Config. In the shortcut menu, select the menu command Object Properties. The "Properties - ..." dialog box opens. 2. Click the button for the associated bus system in the "Node/ ...system" area. The "Properties - ...Interface " dialog box opens. 3. Enter the desired bus address. HW Config automatically assigns addresses in the order in which objects are created. You may need to correct these addresses, depending on the device used (refer to the device manual). Click the "OK" button to save the address. 4. Click "OK" to close the "Properties - ..." dialog boxes. 5. Save the project with the menu command Station > Save. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 83

Integrating a HART device in a HART modem network

��������������� Figure 7-1 HART modem The following describes how to integrate a HART device in a HART modem network. Requirements ● A project has been created. ● The device description files (EDD) for planned or already installed field devices are available in SIMATIC PDM. ● An access point of the computer is set to the COM port to which the HART modem network is connected. Integrating a HART device in a HART modem network 1. Open the project in the process device network view. 2. Right-click the "Networks" object in the tree structure. In the shortcut menu that opens, select the menu command Insert New Object > Communication network. The "Insert Object(s) - <...>" dialog box opens. 3. Click the "Assign Device Type" button. The "Insert Object(s) - Assign Device Type" dialog box opens. You can find additional information in the section "Insert Object - Assign Device Type" dialog box (Page 79). 4. To set the network properties, select the inserted HART modem network in the right window and right-click. Select the Object Properties command in the displayed shortcut menu. 5. Enter the device-specific information in the "Communication" tab of the Properties dialog for the HART modem network. Set the master type (primary or secondary, usually secondary): Here, you can select the "Prefer 'Long address'" check box. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 84 Operating Manual, 02/2014, A5E33203676-AA

6. To check if the correct network and the correct port are assigned to the COM interface,

double-click the "PC" object in the right window. Select the "COM interface" object in HW Config, and select the Object Properties menu command in the shortcut menu. Note The COM port is almost always "1" for notebooks. Since most PCs have two COM ports, you must specify the port to which the HART modem is connected in this tab. Check whether the settings for the FIFO buffer of the COM port are suitable, or immediately use a USB HART modem. 7. To insert the HART device, select the "HART modem network" object in the right window and right-click. In the displayed shortcut menu, select the Insert New Object > Object command. In the displayed dialog box, enter the name of the HART device. 8. To set the device address, select the inserted HART device in the right window and right- click. Select the Object Properties command in the displayed shortcut menu. 9. Enter the device-specific information (long address) in the "Communication" tab of the Properties dialog for the HART device. Note Address with HART The information must correspond to the connected device. ● The short address must be entered for HART devices. This address must correspond to the connected HART device. The short address is always "0", unless the device is in the multi-drop function. ● For a HART interface, enter the long address. This address contains the following device-specific information: – Manufacturer – Device type – Device name Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 85

10.To change the device address, select the inserted HART device in the right window and

then select the Object properties menu command in the shortcut menu. Select the "Communication" tab in the displayed dialog and enter the new short address. Note The address must correspond to the connected device. The short address for HART devices is always "0" unless the device is in the multi-drop function. 11.Start SIMATIC PDM by double-clicking the newly inserted HART device in the right window. Select the relevant device in the menu tree (only required for the first call), and assign parameters for the device. Note Multiple PCs in one project If there are several PCs in your project, you have to define one of them as the current one. To do this, select the desired "PC" object in the left window and then select the menu command Options > Define Current PC. 7.3.1.7 Integrating a MODBUS device in a MODBUS network ������ The following paragraph describes how you integrate a MODBUS device in a MODBUS network. Requirements ● A project has been created. ● The device description files (EDD) for planned or already installed field devices are available in SIMATIC PDM. Integrating a MODBUS device in a MODBUS network 1. Open the project in the process device network view. 2. Right-click the "Networks" object in the tree structure. In the shortcut menu that opens, select the menu command Insert New Object > Communication network. The "Insert Object(s) - <...>" dialog box opens. 3. Click the "Assign Device Type" button. The "Insert Object(s) - Assign Device Type" dialog box opens. You can find additional information in the section "Insert Object - Assign Device Type" dialog box (Page 79). 4. To set the network properties, select the inserted MODBUS network in the right window and right-click. Select the Object Properties command in the displayed shortcut menu. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 86 Operating Manual, 02/2014, A5E33203676-AA

5. Enter the device-specific information in the "Communication" tab of the Properties dialog

for the MODBUS network. MODBUS communication type: Serial or IrDA (infrared) Serial The interface must be set accordingly on the PC station. IrDA No additional setting required. Once the device is within range, it is available for MODBUS communication. Only one infrared device can be coupled to MODBUS at a given time. Several devices can be coupled under Windows. Response time General timeout within which the device is allowed to report. If the timeout is too long, the communication is slowed. If it is too short, some devices may not be found. 6. To check if the correct network and the correct port are assigned to the COM interface, double-click the "PC" object in the right window. Select the "COM interface" object in HW Config, and select the Object Properties menu command in the shortcut menu. Note The COM port is almost always "1" for notebooks. Since most PCs have two COM ports, you have to specify which port the device is connected to in this tab. 7. To insert the MODBUS device, select the "MODBUS network" object in the right window and right-click. In the displayed shortcut menu, select the Insert New Object > Object command. In the displayed dialog box, enter the name of the MODBUS device. 8. To set the device address, select the inserted MODBUS device in the right window and right-click. Select the Object Properties command in the displayed shortcut menu. 9. Enter the device-specific information (MODBUS address 0-247) in the "Communication" tab of the Properties dialog for the MODBUS device. 10.To change the device address, select the inserted MODBUS device in the right window and then select the Object Properties menu command in the shortcut menu. Select the "Communication" tab in the displayed dialog and enter the new short address. 11.Start SIMATIC PDM by double-clicking the newly inserted MODBUS device in the right window. Select the relevant device in the menu tree (only required for the first call), and assign parameters for the device. Note Multiple PCs in one project If there are several PCs in your project, you have to define one of them as the current one. To do this, select the desired "PC" object in the left window and then select the menu command Options > Define Current PC. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 87

Integrating a HART server network

You can use SIMATIC PDM to configure HART devices for the following networks: ● Multiplexer networks – Multiplexer network with panel (for example, MTL multiplexer) – Multiplexer network without panel (for example, P+F multiplexer) ● Wireless Hart gateway You configure a wireless HART gateway as a HART multiplexer. You need a HART server application in the project to integrate and manage these networks. You can find detailed information on the HART server in the description or the online help for this product. ● You can address multiplexers using the HART server. You can obtain more information from the device manufacturers. ● The HART server of SIMATIC PDM does not support multimaster operation. Jobs have to be coordinated to avoid conflicts. This coordination has to take place on the multiplexer network level. Requirement ● A HART server is installed on the computer. ● A multiplexer network has been integrated in the HART server. ● A project has been created in the SIMATIC Manager. ● The HART network is physically connected to the PC station. Note Integrating a HART multiplexer network In the HART server, a project has to be created for the multiplexer in order for the configuration data of the multiplex to be available in the process device network view. Starting the HART server application Note HART server The HART server application should always be open before you configure or integrate HART devices. You have the following options for starting the HART server application: Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 88 Operating Manual, 02/2014, A5E33203676-AA

In SIMATIC Manager, select the menu command Options > SIMATIC PDM > HART server.

● In the Windows taskbar, select the menu command Start > Programs > HART server > HART server (path of the HART server created by SIMATIC PDM setup). Note Network address of the HART multiplexer Enter the network address of the HART multiplexer in the HART server application when you create an I/O system in the HART network. Starting the HART server application for the first time To configure communication between SIMATIC PDM and the HART server, proceed as follows: 1. Select the HART server project. Select the menu command File > Preferences. The "HART Server Preferences" dialog box opens. 2. In the "New Configuration Will Use" section, select the check box according to your settings in SIMATIC PDM. 3. Apply this setting also to the existing project, if required. After it has been applied to an existing project, the devices must be read in again with "Learn". Note SIMATIC PDM default settings The default settings for HART communication in SIMATIC PDM correspond to the "8 char (HART 5), 32 char (HART 6 +)" check box. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 89

Configuring the HART server

1. Select the HART server project. Right-click and select the shortcut menu command Add Network. In the dialog box that opens, select the type of network through which the objects are connected: – Single Port RS485 – Single Serial Port – TCP/UDP 2. Enter a name in the "Network Properties" field. SIMATIC Manager later identifies the network based on this name. Set the properties of the interface under "Properties" and confirm your entries with "OK". The network is inserted in the project. Note TAG names Ensure that the TAG names of the components do not contain a "." (dot) character. 3. You can read in the multiplexer data automatically or configure them manually. – Automatic reading: Select the higher-level object. Right-click and select the shortcut menu command Learn. All data (multiplexers and devices) of the selected object are read out. A dialog box indicates the progress. While the addresses (multiplexer, etc.) are being checked, the status of all assigned addresses changes from "not responding" to "responding". If this does not happen, there is a connection error, such as incorrect polarity. Note Learning process in a HART server project You can start the learning process on any level. ● When you select a network, you start the learning process for the entire configuration tree. ● If you select a panel, you start the learning process for the selected partial configuration, meaning for the instruments below the panel level. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 90 Operating Manual, 02/2014, A5E33203676-AA

Example 1: HART server project with serial multiplexers

Figure 7-3 Example 2: HART server project with wireless HART gateway – Manual configuration: If you want to create the configuration manually, select the project, followed by the shortcut menu command Add Device (or Add IO-System for Ethernet networks). Enter the required information in the dialog box. Continue this procedure until all the devices have been configured. The HART server immediately checks whether a HART multiplexer is available at the selected address: If a HART multiplexer is reached, its properties are displayed. Otherwise, a message is generated indicating that no connection could be established. HART multiplexer with panel: Configure the address information for the panel before you configure the HART devices. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 91

Inserting a HART server in a multiplexer network

1. Check whether the HART server is started. 2. Open the project in the process device network view. 3. Right-click and select the following shortcut menu command: Insert New Object > Communication network. The "Insert Object - " dialog box opens. 4. Click the button "Assign Device Type" > Object. The "Insert Object - " dialog box opens. Select "HART server" as the network type and click the "Assign Device Type" button. 5. Select the following shortcut menu command: SIMATIC PDM > Synchronize. If you select the "Object with all subordinate objects and networks" option, all devices and multiplexers detected in the HART server are automatically applied to the project. The hierarchy is transferred to the SIMATIC Manager. The levels displayed in the SIMATIC Manager depend on the selected multiplexer (e.g. single-stage or two-stage). 6. In the process device network view of SIMATIC Manager, insert the HART server in the HART multiplexer network and edit the individual devices. Configuring the devices Note the following: ● You can start a learning process for identification of the devices on the multiplexer and assign the device description files (EDD) automatically. ● You can manually configure the multiplexer and the devices. For this purpose, the devices and the computer must be connected and the device names and addresses must be known. Changing the configuration If, for example, you change an existing multiplexer network by inserting a new device or replacing a device (must be followed by reconfiguration in the HART server), you can compare the changes in the HART server with the menu command Edit > SIMATIC PDM > Synchronize. The comparative function takes the following into consideration: ● New hierarchy and devices are inserted. ● Hierarchies and devices that no longer exist are removed. ● Renamed devices are also renamed in PDM. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 92 Operating Manual, 02/2014, A5E33203676-AA

Wireless HART device on a Wireless HART gateway

Wireless HART devices are integrated into HART multiplexer networks the same way as HART devices. IE/WSN- PA LINK SITRANS AW210 SITRANS AW200 SITRANS AW210 SITRANS TF280 SITRANS P280 Wireless HART PDM Ethernet Renaming devices downstream from a HART server project If you want to rename a device on a HART multiplexer, observe the order in which the actions must be performed: 1. Open the device with SIMATIC PDM. 2. Enter new TAG in PDM. 3. Select the following shortcut menu command: SIMATIC PDM > Download to device... 4. Save in PDM Saving automatically applies the changes to the HART server. Additional information Information on configuring the HART server application supplied with PDM can be found in the online help HART Server Help(Start > Programs > HART Server > HART Server Help). For information on the structure, configuration, and commissioning of wireless HART devices on an IE/WSN PA link (WSN-PA Link link), refer to the following documentation: Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 93

Operating instructions titled SIMATIC NET; IE/WSN PA Link

● Operating instructions titled SIMATIC NET; IE/WSN PA Link (Compact) 7.3.1.9 Compact PROFIBUS device (sensors and actuators) Procedure To integrate a PROFIBUS device (PROFIBUS DP device, PROFIBUS PA device or PROFIBUS remote I/O), proceed as follows: ����������� ����������� ����������� ����������� ����������� ����������� �������� Creating a network 1. Open the process device network view in SIMATIC Manager. 2. Select the "Networks" folder in the tree structure in the left window and select the Insert New Object > Object command from the shortcut menu. The "Insert Object" dialog box opens. 3. Click the "Assign Device Type" button. Inserting a PROFIBUS device or remote I/O Follow the steps below to insert objects into higher-level objects one after the other. Higher-level object Object to be inserted "Networks" folder Type of network via which the field devices are connected to the automation system (e.g., PROFIBUS DP network). PROFIBUS DP network PROFIBUS DP device / PROFIBUS PA device Header module (selection: remote I/O) Modules (selection: module) Modules (selection: module) Field device (selection: HART device) Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 94 Operating Manual, 02/2014, A5E33203676-AA

1. Select the higher-level object in the tree structure in the window on the right.

2. In the shortcut menu, select the menu command Insert New Object > Object. The dialog box "<... SIMATIC PDM – Insert Object(s)" opens. 3. In the dialog box that opens, enter the name of the process tag. Note Configure the PROFIBUS PA devices directly on the PROFIBUS network if you are using a PROFIBUS DP/PA coupler. The coupler itself is not configured (the DP/PA couplers with diagnostic capability as of 6ES7157-0AC84-0XA0 can be configured as a stand-alone device). 4. Alternatively, you can add a PROFIBUS-Link (Y-Link or DP/PA-Link) to a PROFIBUS DP network. Downstream of the PROFIBUS-Link , you can then insert PROFIBUS devices, but not another PROFIBUS-Link . Note The address of the PROFIBUS device that you set in the "Insert SIMATIC PDM Object(s)" dialog box can be changed afterwards on the "Communication" tab of the "Object Properties" dialog box. Configuring devices with SIMATIC PDM 1. Select the inserted PROFIBUS device in the process device network view. 2. Select the Open object command in the shortcut menu. SIMATIC PDM opens. The PROFIBUS device is shown in the structure view. 3. Set the required parameters for the function in the parameter table. 4. Make the necessary settings and save the object. 7.3.1.10 Modular PROFIBUS device (remote I/O) Creating a network 1. Open the process device network view in SIMATIC Manager. 2. Double-click the "Networks" object in the right window to insert a PROFIBUS DP network. Select the "Networks" folder in the left window, and select the Insert New Object > Communications Network command in the shortcut menu. The "Insert Object(s) - <...>" dialog box opens. 3. Click the "Assign device type" button. The "Insert Object - Assign Device Type" dialog box opens. You can find additional information on this in the section ""Insert Object - Assign Device Type" dialog box (Page 79)". 4. Select the PROFIBUS DP network from the tree structure. 5. Click "OK". The PROFIBUS DP network is inserted. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 95

Adding remote I/O, module, and PROFIBUS device

Follow the steps below to insert objects into higher-level objects one after the other. Higher-level object Object to be inserted PROFIBUS DP network Header module (selection: remote I/O) Header module (selection: remote I/O) Modules (selection: module) Modules (selection: module) Field device (selection: PROFIBUS device) 1. Select the higher-level object in the tree structure in the window on the left. 2. In the shortcut menu, select the menu command Insert New Object > Object. The "Insert Object(s) - <...>" dialog box opens. 3. Make the following settings for the inserted object. You can find additional information on this in the section "Inserting objects (Page 77)". 4. Select the object. Select the Object properties command in the shortcut menu. The "Properties - " dialog box opens. 5. Select the "Communication" tab. 6. Make the necessary settings depending on the inserted object in the input fields: – Remote I/O: Enter the PROFIBUS address. – Module (device module): Enter the slot. – PROFIBUS devices: Do not make changes to the channel settings. 7. Repeat these steps until all remote I/O, modules, and PROFIBUS devices have been added. Configuring devices with SIMATIC PDM 1. Select the PROFIBUS DP network in the process device network view, which is of a higher level than the added PROFIBUS devices. 2. Select the Open object command in the shortcut menu. SIMATIC PDM opens. The PROFIBUS DP network is represented in the structure view. You can find the remote I/O, modules, and PROFIBUS devices by opening the tree structure. 3. Assign a function individually to the added objects (corresponding with the actual configuration in HW Config and the connected equipment): – Open the object by selecting its icon in the structure view. – Select the parameters required for the function in the parameter table. Make the required settings and save the object. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 96 Operating Manual, 02/2014, A5E33203676-AA

To transfer the configuration and parameters, select the "" object and then select

the Device > Upload to PC/PG... menu command. Note The automatic detection of the depends on the type of , the , and the device description. 7.3.1.11 Connecting a field device to PROFINET To integrate distributed I/O devices (e.g., ET 200M) or links for connecting intelligent DP or PA field devices (e.g., IE/PB link) via PROFINET, follow these steps: Creating a network 1. Open the process device network view in SIMATIC Manager. 2. Select the "Networks" folder in the tree structure in the left window and select the Insert New Object > Object command from the shortcut menu. The "Insert Object" dialog box opens. 3. Click the "Assign Device Type" button. Inserting a field device or remote I/O Follow the steps below to insert objects into higher-level objects one after the other. Higher-level object Object to be inserted "Networks" folder Type of network via which the field devices are connected to the automation system (e.g., PROFINET network). PROFINET network Header module (selection: remote I/O) Header module (selection: remote I/O) Modules (selection: module) Modules (selection: module) Field device (selection:HART device) 1. Select the higher-level object in the tree structure in the window on the right. 2. In the shortcut menu, select the menu command Insert New Object > Object. The dialog box "<... SIMATIC PDM – Insert Object(s)" opens. 3. In the dialog box that opens, enter the name of the process tag. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 97

Alternatively, you can add a IE/PB-Link to a PROFINET network. Downstream of the IE/PB-

Link , you can then insert PROFIBUS devices. IE/PB-Links are only supported in HW Config in V8.0. Note The address of the PROFINET device that you set in the "Insert SIMATIC PDM Object(s)" dialog box can be changed afterwards on the "Communication" tab of the "Object Properties" dialog box. Network topology ����������� ����������� ����������� �������� Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 98 Operating Manual, 02/2014, A5E33203676-AA

Configuring devices with SIMATIC PDM

1. Select the inserted PROFINET device in the process device network view. 2. Select the Open Object command from the shortcut menu. SIMATIC PDM opens and the PROFINET device is shown in the structure view. 3. Set the required parameters for the function in the parameter table. 4. Make the necessary settings and save the object. 7.3.1.12 HART device on remote I/O You can connect the HART devices to a suitable remote I/O module. Functions 7.3 Device management Help for SIMATIC PDM (V8.2) Operating Manual, 02/2014, A5E33203676-AA 99

Remote I/O with HART devices (PROFIBUS DP)

����������� �������� Creating the PDM basic folder called "Networks" 1. Open the process device network view in SIMATIC Manager. 2. If the "Networks" object has not been inserted in the tree structure, select the menu command Insert New Object and select the "Networks" object. Note PDM basic folder called "Networks" SIMATIC PDM licenses must be available in the project when this folder is created. Creating a communications network 1. Open the process device network view in SIMATIC Manager. 2. Select the "Networks" folder in the tree structure in the left window and select the Insert New Object > Object command from the shortcut menu. The "Insert Object - <...>" dialog box opens. 3. Click the "Assign Device Type" button. Inserting an object (creating a communications network; remote I/O, module, and HART device) Follow the steps below to insert objects into higher-level objects one after the other. Higher-level object Object to be inserted "Networks" folder Type of network via which the field devices are connected to the automation system (e.g., PROFIBUS DP network or PROFINET). PROFIBUS DP network Header module (selection: remote I/O) Functions 7.3 Device management Help for SIMATIC PDM (V8.2) 100 Operating Manual, 02/2014, A5E33203676-AA