Shimaden SR90 Series Instruction Manual

File Specifications

Brand: Shimaden
Category: Controller
Model: SR90 Series (Instruction Manual), pr3XsMCVEXvZE
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 16 pages

Download PDF

Download Shimaden SR90 Series Manual (16 pages)

Read Online:

Read the Shimaden SR90 Series Instruction Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

(2) Priority order of response codes

The smaller the value of response code, the higher the priority of the response code; When two or more response codes are generated, a response code of higher priority order is returned. 5-6. Details of communication data addresses (1) Data address and read/write • In a data address, binary numbers (16 bit data) are expressed by hexadecimal numbers, with 4 bits as a unit. • R/W means that data are capable of being read and written. • R means that data are only for reading. • W means that data are only for writing. • In case a data address only for ...

- 16 -

b7b6b5 000 001 010 011 100 101 110 111 0 1 2 3 4 5 6 7 NUL TC7 (DLE) 0 1 2 3 4 5 6 7 8 9 TC1 (SOH) DC1 ! TC2 (STX) DC2 TC3 (ETX) DC3 # TC4 (EOT) DC4 $ TC5 (ENQ) TC8 (NAK) % TC6 (ACK) TC9 (SYN) & BEL TC10 (ETB) FE0 (BS) CAN ( FE1 (HT) EM ) FE2 (LF) SUB ∗ : FE3 (VT) ESC + ; [ FE4 (FF) IS4 (FS) , < \ FE5 (CR) IS3 (GS) SO IS2 (RS) . > ^ SI IS1 (US) DEL b4 ~ b1 0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111 0 1 2 3 4 5 6 7 8 9 A B C D E F _ _ / SP = ? @ A P B C D E F G H I J Q R S T U V W X Y Z p q r s t u v w x y z K L M N O a b c d e f g h i j k l m n o ] ...

To the above read command (R), the following data are returned one by one as response data:

Thus, the above data can be read. (3) Abnormal response format to read command (R) • The following is the abnormal response format (text portion) to read commands (R): (The basic format portions I and II are common to all commands and responses.) • d( ): indicating that it is a response to a read command (R) is inserted. • e( , ): A response code indicating that it is an abnormal response to the read command (R) is inserted. • For details of abnormal response code, refer to 5-5. De ...

- 15 -

Data address (hex) Parameter R/W Setting range 0704 0705 0706 0707 0708 0709 R/W R/W R/W R/W R/W R/W UNIT Unit of input data Refer to 7-1. Table of measuring range codes 0: None 1: 0.1 2: 0.01 3: 0.001 –1999 ~ 9989 UNIT –1989 ~ 9999 UNIT RANGE Reserved DP SC_L SC_H 0: "˚C" 1: "˚F" Unchangeable except linear input Measuring range 0 0.0 0 0 0 -199.9 -199.9 -200 -200 0 0 0 0 0 0 -199.9 400.0 800.0 200.0 200.0 -100.0 -50.0 50.0 0.0 200.0 -100.0 -50.0 0.0 100.0 100.0 50.0 200.0 1700 1200 1300 1300 2300 700 600 600 600 500 1700 1800 °C °F Code 01 02 03 04 05 06 07 08 09 10 11 12 1 ...

• Data is always preceded by comma ("," 2CH) to show the subsequent portion is data.

• No punctuation code is used between data and data. • The number of data is determined by the number of data (f: ) of the communication command format. • Each data is expressed by binary 16 bits (1 word), excluding a decimal point, as a unit. The position of decimal point is fixed in each data. • 16 bit data are split into 4 bit groups and respectively converted to ASCII data. • For details of data, refer to 5-3. Details of read commands (R) and 5-4. Details of write command (W). e : Response code ...

(4) in parameter portions

• When a portion is read in reply to a read command (R), or written in replay to a write command (W), normal response code "0", "0" (30H, 30H) is returned. (5) Option-related parameters • When the data address of a parameter which is not added as an option is designated, abnormal response code "0", "C" (30H, 43H)"Specification, option error" is returned to a read command (R) as well as a write command (W). If an address of data only for reading is read, however, the (0000H) data are returned. (6) Parameters not shown in front panel displays ...

Shimaden SR90 Series user guide recommended for: SR1 Series, SRS10A Series, KR16A Series, SR253 Series, SR23 series.

⚠️ Download Safety

The Controller Instruction manual (16 pages) is completely safe to download (last scan date: 02/01/2026).

Related PDF Instructions for Shimaden SR90 Series:

Controller Equipment: Frequently Requested

Have some Questions about Shimaden SR90 Series Device?

Get valuable and actionable advices from other Shimaden SR90 Series device users. Describe your problem or question, regarding the using of SR90 Series, in as much detail as possible, and other users will be able to answer you.