YASKAWA PROFINET V1000 Technical Manual
Text of the manual
YASKAWA AC Drive-V1000 Option
Technical Manual
MANUAL NO. SIEP C730600 70B
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.
Type: SI-EP3/V
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Copyright © 2016 YASKAWA ELECTRIC CORPORATION
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any
means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of Yaskawa. No patent
liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to
improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has
been taken in the preparation of this manual. Yaskawa assumes no responsibility for errors or omissions. Neither is any liability
assumed for damages resulting from the use of the information contained in this publication.
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
3
Table of Contents
1
PREFACE AND SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2
PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3
RECEIVING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4
OPTION COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5
INSTALLATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6
RELATED DRIVE PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
7
PROFINET MESSAGING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
8
COMMUNICATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
9
WEB INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
10 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
11 EUROPEAN STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
12 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
1 Preface and Safety
1
Preface and Safety
YASKAWA Electric supplies component parts for use in a wide variety of industrial applications. The selection and
application of YASKAWA products remain the responsibility of the equipment designer or end user.
YASKAWA accepts no responsibility for the way its products are incorporated into the final system design. Under no
circumstances should any YASKAWA product be incorporated into any product or design as the exclusive or sole safety
control. Without exception, all controls should be designed to detect faults dynamically and fail safely under all
circumstances. All products designed to incorporate a component part manufactured by YASKAWA must be supplied to
the end user with appropriate warnings and instructions as to the safe use and operation of that part. Any warnings
provided by YASKAWA must be promptly provided to the end user. YASKAWA offers an express warranty only as to
the quality of its products in conforming to standards and specifications published in the manual. NO OTHER
WARRANTY, EXPRESS OR IMPLIED, IS OFFERED. YASKAWA assumes no liability for any personal injury,
property damage, losses, or claims arising from misapplication of its products.
Applicable Documentation
The following manuals are available for the option:
Terms
Registered Trademarks
• PROFINET is a registered trademark of PROFIBUS and PROFINET International (PI).
• Trademarks are the property of their respective owners.
Option Unit
YASKAWA AC Drive-V1000 Option
SI-EP3/V PROFINET
Installation Manual
Manual No: TOBP C730600 70
Read this manual first.
The installation manual is packaged with the option and contains a
basic overview of wiring, settings, functions, and fault diagnoses.
YASKAWA AC Drive-V1000 Option
SI-EP3/V PROFINET
Technical Manual
Manual No: SIEP C730600 70
(This book)
The technical manual contains detailed information about the
option pertaining to communication protocols, and supported
features and messaging. Access the following sites to obtain the
technical manual:
U.S.: http://www.yaskawa.com
Europe: http://www.yaskawa.eu.com
Japan: http://www.e-mechatronics.com
Other areas: contact a Yaskawa representative.
Drive
YASKAWA AC Drive-V1000
Quick Start Guide
Access the following sites to obtain instruction manuals for
Yaskawa products:
U.S.: http://www.yaskawa.com
Europe: http://www.yaskawa.eu.com
Japan: http://www.e-mechatronics.com
Other areas: contact a Yaskawa representative.
For questions, contact the local Yaskawa sales office or the nearest
Yaskawa representative.
YASKAWA AC Drive-V1000
Technical Manual
Note:
Indicates supplemental information that is not related to safety messages.
Drive:
YASKAWA AC Drive V1000
Option:
YASKAWA AC Drive -V1000 Option SI-EP3/V PROFINET
V/f:
V/f Control
OLV/PM:
Open Loop Vector Control for PM
H:
Indicates an engineering unit for hexadecimal number format.
STOP
1 Preface and Safety
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
5
Supplemental Safety Information
Read and understand this manual before installing, operating, or servicing this option. Install the option according to this
manual and local codes.
The following conventions indicate safety messages in this manual. Failure to heed these messages could cause fatal
injury or damage products and related equipment and systems.
General Safety
DANGER
Indicates a hazardous situation, which, if not avoided, will cause death or serious injury.
W ARNING
Indicates a hazardous situation, which, if not avoided, could cause death or serious injury.
CAUTION
Indicates a hazardous situation, which, if not avoided, could cause minor or moderate injury.
NOTICE
Indicates an equipment damage message.
General Precautions
• The diagrams in this book may include options and drives without covers or safety shields to illustrate details. Be sure to reinstall
covers or shields before operating any devices. Use the option according to the instructions described in this manual.
• The diagrams in this manual are provided as examples only and may not pertain to all products covered by this manual.
• The products and specifications described in this manual or the content and presentation of the manual may be changed without
notice to improve the product and/or the manual.
• Contact a Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cove to
order new copies of the manual.
DANGER
Heed the safety messages in this manual.
Failure to comply will cause death or serious injury.
The operating company is responsible for any injuries or equipment damage resulting from failure to heed the warnings
in this manual.
W ARNING
Electrical Shock Hazard
Do not attempt to modify or alter the drive or drive circuitry in any way not explained in this manual.
Failure to comply could cause death or serious injury and will void warranty. Yaskawa is not responsible for any
modification of the product made by the user. Do not modify this product.
NOTICE
Do not expose the drive or the option to halogen group disinfectants. Do not pack the drive or the option in
fumigated or sterilized wooden materials. Do not sterilize the entire package after packing the product.
Failure to comply could damage electrical components in the option.
1 Preface and Safety
6
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Option Unit Warning Labels
Warning information is displayed on the option unit as shown in the figure below. Follow all warnings and safety
instructions when using the product.
A warning label is provided with the option when using the drive in an area that requires displaying warning information
in Japanese or Chinese. This label can be placed over the English and French warnings on the front of the option.
Warning Contents
V1000
Warning
information
AVERTISSEMENT
Lire le manuel avant l'installation.
Attendre 5 minutes apres la coupure de l'alimentation,
pour permettre la decharge des condensateurs.
Pour repondre aux exigences , s assurer que le
neutre soit relie a la terre, pour la serie 400V.
WARNING
Read manual before installing.
Wait 5 minutes for capacitor discharge after
disconnecting power supply.
To conform to � requirements, make sure
to ground the supply neutral for 400V class.
Risk of electric shock.
Risque de decharge
electrique.
V1000
AVERTISSEMENT
Lire le manuel avant l'installation.
Attendre 5 minutes apres la coupure de l'alimentation,
pour permettre la decharge des condensateurs.
Pour repondre aux exigences , s assurer que le
neutre soit relie a la terre, pour la serie 400V.
WARNING
Read manual before installing.
Wait 5 minutes for capacitor discharge after
disconnecting power supply.
To conform to � requirements, make sure
to ground the supply neutral for 400V class.
Risk of electric shock.
Risque de decharge
electrique.
V1000
2 Product Overview
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
7
2
Product Overview
About This Product
This option provides a communications connection between the drive and a PROFINET network. The option connects
the drive to a PROFINET network and facilitates the exchange of data.
This manual explains the handling, installation and specifications of this product.
PROFINET is a communications link to connect industrial devices (such as smart motor controllers, operator interfaces,
and variable frequency drives) as well as control devices (such as programmable controllers and computers) to a
network. PROFINET is a simple, networking solution that reduces the cost and time to wire and install factory
automation devices, while providing interchangeability of like components from multiple vendors.
Install the option/PROFINET option on a drive to perform the following functions from a PROFINET master device:
• Operate the drive
• Monitor the drive operation status
• Change drive parameter settings
SI-EP3/V is PROFINET Conformance Class A certified.
Applicable Models
The option can be used with the models in Table 1.
Table 1 Applicable Models
Note:
Refer to the option package labeling in the field designated “PRG” (four digit number)” or the option nameplate in the field
designated “C/N” (S + four digit number)” to identify the option software version. The nameplate is located adjacent to the PCB.
Drive Series
Model Number
Software Version <1>
<1> Refer to “PRG” on the drive nameplate for the software version number.
V1000
CIMR-VA
≥1012
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
3 Receiving
3
Receiving
After receiving the option package:
1. Make sure that the option is not damaged and no parts are missing. Contact your sales outlet if the option or other parts
appear damaged.
NOTICE: Do not use damaged parts to connect the drive and the option. Failure to comply could damage the drive and option.
2. Confirm that the model number on the option nameplate and the model listed in the purchase order are the same. Refer
to on page for details. Contact the distributor where the option was purchased or the Yaskawa sales office
immediately about any problems with the option.
Option Package Contents
Table 2 Option Package Contents
Installation Tools
A Phillips screwdriver (M3, M3.5 to M6 metric or #1, #2 U.S. standard <1>) is required to install the option.
Description:
Option Unit
Ground Wire
Warning Labels
Installation Manual
_
Quantity:
1
4
1
1
<1> Screw sizes vary by drive capacity. Select a screwdriver that matches the drive capacity.
MANUAL
4 Option Components
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
9
4
Option Components
SI-EP3/V Option
Figure 1
Figure 1 Top Views of Option
Dimensions
The installed option adds 27 mm (1.06 in.) to the total depth of the drive.
Figure 2
Figure 2 Dimensions
A – LED (MS) <1>
J – Pass-through hole for wire
B – LED (NS) <1>
K – Port 1 LED (10/100) <1>
C – Option cover
L – Port 1
<1> Refer to Option LED Display on page 11 for details on the LEDs.
<2> Ground wires are packaged loose inside the option packaging and must be connected during installation.
D – PROFINET PCB
M – Port 1 LED (LINK/ACT) <1>
E – Screw hole (attaching option cover)
N – Port 2 LED (10/100) <1>
F – Nameplate
O – Port 2
G – Functional Earth cable connection (FE)
P – Port 2 LED (LINK ACT) <1>
H – Mounting tabs
Q – PROFINET cable connector
I – Ground wire <2>
R – Option connector
A
B
C
H
E
D
H
G
I
J
R
F
Q
00000000000000
SI-EP3/V
1XXX
P
N
K
M
O
L
Option with cover removed
Underside
Option with cover attached
V1000
27 mm (1.06 in.)
V1000
4 Option Components
10
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Communication Modular Connector CN1 Port 1/Port 2
The communication modular connector CN1 on the option is a modular dual RJ45 female connector designated port 1
and port 2. Port 1 and port 2 are the connection point for a customer supplied male Ethernet network communication
cable.
Figure 3
Figure 3 Communication Modular Connector CN1 Port 1/Port 2 (RJ45)
Table 3 Male 8-way Ethernet Modular Connector (Customer-Supplied)
Male EtherNet 8-Way Modular Connector
Pin
Description
1 (Pair 2)
Transmit data (TXD) +
2 (Pair 2)
Transmit data (TXD) -
3 (Pair 3)
Receive data (RXD) +
4 (Pair 1)
Not used <1>
<1> Not used for 10 Mbps and 100 Mbps networks.
5 (Pair 1)
Not used <1>
6 (Pair 3)
Receive data (RXD) -
7 (Pair 4)
Not used <1>
8 (Pair 4)
Not used <1>
V1000
4 Option Components
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
11
Option LED Display
The option has six LEDs:
Bi-color Status LEDs:
• Module status (MS) red/green
• Network status (NS) red/green
Ethernet LEDs (2 each):
• Network speed-10/100 yellow
• Link status and network activity-Link/Act green
Figure 4
Figure 4 Option LED Labels
The operational states of the option LEDs after the power-up diagnostic LED sequence is completed are described in
Table 4. The states with a number in parenthesis are the number of pulses of 250 ms on, 250 ms off cycles, followed by
500 ms off, then repeating the cycle. Wait at least 2 seconds for the power-up diagnostic process to complete before
verifying LED states.
Table 4 Option LED States
Name
Indication
Operating Status
Description
Color
Status
MS
(visible through
drive cover)
–
OFF
Power supply OFF
Power is not being supplied to the drive.
Green
ON
Option operating
The option is operating normally and
initialization is complete.
Green
Flashing (1)
Diagnostics
Diagnostic data available.
Green
Flashing (2)
Configuration tool
Identified by a configuration tool.
Red
ON
Default MAC or fatal error occurred.
Default MAC address has been programmed or
the option has detected an unrecoverable error.
Red
Flashing (1)
Configuration error (non-fatal)
Configuration error.
Red
Flashing (2)
No IP (non-fatal)
No IP address assigned.
Red
Flashing (3)
No station name (non-fatal)
No station name assigned.
Red
Flashing (4)
Init failure (non-fatal)
Failed to initialize module.
Green/Red
Flashing
Option self-test
The option is in self-test mode.
NS
(visible through
drive cover)
–
OFF
Offline or Power supply OFF
–
Green
ON
Connected
Connection established with I/O controller and
in RUN mode.
Green
Flashing
Connected and stopped
Connection established with I/O controller and
in STOP mode.
Red
ON
BUS fault
Unrecoverable BUS fault.
Red
Flashing (1)
Lost communication
Host communication is temporarily lost.
Red
Flashing (2)
Lost link
No link detected to network.
10/100
(visible at
RJ45 jack)
Yellow
OFF
10 Mbps is established
–
Yellow
ON
100 Mbps is established
–
LINK/ACT
(visible at
RJ45 jack)
Green
OFF
Link is not established
–
Green
ON
Link is established
–
Green
Flashing
Link is established and there is network
activity
–
GA700 Label
1000-Series Label
NS
MS
4 Option Components
12
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Power-Up Diagnostics
An LED test is performed each time the drive is powered up. The initial boot sequence may take several seconds. After
the LEDs have completed the diagnostic LED sequence, the option is successfully initialized. The LEDs then assume
operational conditions as shown in Table 4.
Table 5 Power-Up Diagnostic LED Sequence
Sequence
Module Status (MS)
Network Status (NS)
Time (ms)
1
Green
OFF
250
2
Red
OFF
250
3
Green
OFF
–
4
Green
Green
250
5
Green
Red
250
6
Green
OFF
–
5 Installation Procedure
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
13
5
Installation Procedure
Section Safety
DANGER
Electrical Shock Hazard
Do not inspect, connect, or disconnect any wiring while the drive is energized.
Failure to comply will cause death or serious injury.
Before servicing, disconnect all power to the equipment and wait for at least the time specified on the warning label.
The internal capacitor remains charged even after the drive is de-energized. The charge indicator LED will extinguish
when the DC bus voltage is below 50 Vdc. When all indicators are OFF, measure for unsafe voltages to confirm the
drive is safe.
W ARNING
Electrical Shock Hazard
Do not remove option board cover while the power is on.
Failure to comply could result in death or serious injury.
The diagrams in this section may include option units and drives without covers or safety shields to show details. Be
sure to reinstall covers or shields before operating any devices. The option should be used according to the instructions
described in this manual.
Do not allow unqualified personnel to perform work on the drive or option.
Failure to comply could cause death or serious injury.
Only authorized personnel familiar with installation, adjustment, and maintenance of AC drives and options may
perform work.
Do not use damaged wires, stress the wiring, or damage the wire insulation.
Failure to comply could cause death or serious injury.
Fire Hazard
Tighten all terminal screws to the specified tightening torque.
Loose or overtightened connections could cause erroneous operation and damage to the terminal block or start a fire
and cause death or serious injury.
NOTICE
Damage to Equipment
Observe proper electrostatic discharge (ESD) procedures when handling the option, drive, and circuit boards.
Failure to comply could cause ESD damage to circuitry.
Never connect or disconnect the motor from the drive while the drive is outputting voltage.
Improper equipment sequencing could damage the drive.
Do not connect or operate any equipment with visible damage or missing parts.
Failure to comply could further damage the equipment.
Do not use unshielded wire for control wiring.
Failure to comply may cause electrical interference resulting in poor system performance. Use shielded, twisted-pair
wires and ground the shield to the ground terminal of the drive.
5 Installation Procedure
14
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Prior to Installing the Option
Prior to installing the option, wire the drive, make necessary connections to the drive terminals, and verify that the drive
functions normally without the option installed. Refer to the instruction manual packaged with the drive for information
on wiring and connecting the drive.
Installing the Option
Refer to the instructions below to install the option.
DANGER! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply could result in death
or serious injury. Before installing the option, disconnect all power to the drive. The internal capacitor remains charged even after the
power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric
shock, wait at least five minutes after all indicators are off and measure the DC bus voltage level to confirm safe level.
1.
Shut off power to the drive, wait at least five minutes after confirming the DC bus voltage is safe, then loosen the
screw that fastens the front cover in place and remove the front cover. This drive front cover will be replaced by
the option cover. Cover removal varies depending on drive size.
NOTICE: Damage to Equipment. Observe proper electrostatic discharge procedures (ESD) when handling the option, drive, and
circuit boards. Failure to comply may result in ESD damage to circuitry.
Figure 5
Figure 5 Remove Front Cover
2.
The remaining installation steps differ based on drive model. Find the drive model number on the drive
nameplate and refer to the step indicated in Table 6 based on your model number.
Table 6 Installation Steps Based on Drive Model
Properly connect all pins and connectors on the option and drive.
Failure to comply could prevent proper operation and damage equipment.
Confirm that all connections are correct after installing the option and connecting peripheral devices.
Failure to comply could damage the option.
Enclosure Type
<1> Installing the option on an IP20/UL Type 1 enclosure drive voids UL Type 1 protection while maintaining IP20 conformity.
Drive Model
Proceed to Step
Page
IP20/Open-Chassis
CIMR-VAB
3.
15
IP20/UL Type 1 <1>
CIMR-VAF
6.
16
IP66/UL Type 4X without Filter
CIMR-VAG
10.
18
IP66/UL Type 4X with Filter
CIMR-VAH
10.
18
NOTICE
V1000
5 Installation Procedure
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
15
3.
For IP20/Open-Chassis models CIMR-VAB, remove the bottom cover of the drive by applying
pressure to the tabs on each side of the bottom cover. Pull the bottom cover away from the drive while pushing
in on the tabs to release the cover from the drive. Refer to Figure 6 for details.
Refer to Figure 7 for drive models CIMR-VBA0006B to BA0018B, 2A0008B to 2A0069B, and 4A0001B to
4A0038B, which require removing the terminal cover prior to removing the bottom cover.
Figure 6
Figure 6 Remove the Bottom Cover on an IP20/Open-Chassis Drive
(Models CIMR-VBA0001B to BA0003B and 2A0001B to 2A0006B)
Figure 7
Figure 7 Remove the Terminal Cover and Bottom Cover on an IP20/Open-Chassis Drive
(Models CIMR-VBA0006B to BA0018B; 2A0008B to 2A0069B; 4A0001B to 4A0038B)
4.
On IP20/Open-Chassis models, connect the drive side of the ground wire to the drive ground terminal.
Note:
The four different ground wires packaged with the option connect the option to different drive models. Select the proper ground
wire depending on drive size. Refer to Table 7 for ground wire selection by drive model.
Figure 8
Figure 8 Connect the Ground Wire on an IP20/Open-Chassis Drive
V1000
Bottom Cover
Terminal Cover
V1000
Ground terminal
Ground wire
Ground wire
Drive-side
connector
Screw size:
M3.5 to M6
Option
connector
Screw size: M3
V1000
5 Installation Procedure
16
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Table 7 Ground Wire Selection
5.
For IP20/Open-Chassis models, go to Step 17. on page 21.
6.
For IP20/UL Type 1 enclosure models CIMR-VAF, loosen the screw on the front of the terminal
cover and remove it from the drive. Refer to Figure 9 for details.
Refer to Figure 10 for drive models CIMR-VBA0006F to BA0018F, 2A0010F to 2A0069F, and 4A0001F to
4A0038F, which require removing the plastic terminal cover prior to removing the terminal cover.
Note:
Installing the option on an IP20/UL Type 1 enclosure drive voids UL Type 1 protection while maintaining IP20 conformity.
Figure 9
Figure 9 Remove the UL Type 1 Terminal Cover
(CIMR-VBA0001F to BA0003F, 2A0001F to 2A0006F)
Figure 10
Figure 10 Remove the Terminal Cover on an IP20/UL Type 1 Drive
(Models CIMR-VBA0006F to BA0018F; 2A0008F to 2A0069F; 4A0001F to 4A0038F)
Ground Wire Length
mm (in)
Drive Model
CIMR-V
Single-Phase
200 V Class
Three-Phase
200 V Class
Three-Phase
400 V Class
150 (5.9)
BA0001
BA0002
BA0003
2A0001
2A0002
2A0004
2A0006
–
200 (7.9)
BA0006
BA0010
BA0012
BA0018
2A0010
2A0012
2A0020
4A0001
4A0002
4A0004
4A0005
4A0007
4A0009
4A0011
250 (9.8)
–
2A0030
2A0040
4A0018
4A0023
400 (15.7)
–
2A0056
2A0069
4A0031
4A0038
V1000
V1000
5 Installation Procedure
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
17
7.
For models CIMR-VBA0001F to BA0003F, 2A0001F to 2A0006F, loosen the screws attaching the conduit
bracket to the drive to remove the conduit bracket.
Figure 11
Figure 11 Remove the UL Type 1 Conduit Bracket
8.
On UL Type 1 enclosure models (CIMR-VBA0001F to BA0003F, 2A0001F to 2A0006F), the screw for the drive
ground terminal also acts as one of the screws that attaches the conduit bracket to the drive. Reattach the
conduit bracket according to Figure 12 and connect the drive-side of the ground wire to the drive ground
terminal.
Note:
The four different ground wires packaged with the option connect the option to different drive models. Select the proper ground
wire depending on drive size. Refer to Table 7 on page 16 for ground wire selection by drive model.
Figure 12
Figure 12 Reattach the UL Type 1 Conduit Bracket and Connect the Ground Wire for models
CIMR-VBA0001F to BA0003F, 2A0001F to 2A0006F
9.
For IP20/UL Type 1 enclosure models, go to Step 17. on page 21.
V1000
Ground terminal
Ground wire
Drive ground terminal/
conduit bracket screw
Ground wire
Drive-side
connector
Screw size:
M3.5 to M6
Option
connector
Screw size: M3
V1000
5 Installation Procedure
18
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
10. For IP66/UL Type 4X enclosure models, press firmly on the connector release tab holding the LED operator
cable (CN1) in place and disconnect the cable.
Figure 13
Figure 13 Remove the LED Operator Cable
Remove LED operator cable
Connector release tab
Front cover
Front cover bolt
CN1 connector
V1000
5 Installation Procedure
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
19
11. For IP66/UL Type 4X enclosure models, remove the lower terminal cover from the drive, if provided. Apply
pressure using fingers on the left and right tabs. Lift and pull the cover forward to release (see Figure 14).
Note:
The lower terminal cover is required for secure mounting of the option on certain models. Use Table 8 to find the lower terminal
cover part number by model. Contact your Yaskawa representative for ordering, if this part is not available in your drive.
Table 8 IP66/UL Type 4X Lower Terminal Cover Part Number by Model
Figure 14
Figure 14 Remove IP66/UL Type 4X Lower Terminal Cover
12. For IP66/UL Type 4X enclosure models, remove the option cover.
Figure 15
Figure 15 Remove the Option Cover
Drive Model CIMR-V
Terminal Cover Part Number
BA0006, BA0010
2A0010, 2A0012
4A0001 to 4A0009
CVST31300
BA0012
2A0020
4A0011
CVST31301
BA0001 to BA0003
2A0001 to 2A0008, 2A0018, 2A0030 to 2A0069
4A0018 to 4A0038
–
V1000
Option Cover
Mounting Tab
Mounting
Slot
Mounting
Slot
Mounting Tab
V1000
5 Installation Procedure
20
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
13. For IP66/UL Type 4X enclosure models, remove the drive ground terminal screw and option ground terminal
screw (see Figure 16.)
Note:
The screw for the drive ground terminal also acts as one of the screws that attaches the waterproof/dust-proof enclosure to the
drive.
Figure 16
Figure 16 Remove IP66/UL Type 4X Ground Terminal Screw
14. For IP66/UL Type 4X enclosure models, reattach the drive ground terminal screw according to Figure 17.
Note: 1. The screw for the drive ground terminal also acts as one of the screws that attaches the waterproof/dust-proof enclosure to the drive.
2. The four different ground wires packaged with the option connect the option to different drive models. Select the proper ground wire
depending on drive size. Refer to Table 7 on page 16 for ground wire selection by drive model.
Figure 17
Figure 17 IP66/UL Type 4X Ground Wire Connection
15. For IP66/UL Type 4X enclosure models, pass the ground wire into the through-hole for the ground wire, in the
back of the option, and connect the ground wire at the option ground terminal (FE). Tighten the screw to 0.5 to
0.6 Nm or (4.4 to 5.3 in lbs) using an M3 Phillips screwdriver.
Figure 18
Figure 18 Ground Wire Connection Option Side
16. For IP66/UL Type 4X enclosure models, go to Step 22.on page 23.
Drive
Ground terminal
screw
Option
Drive ground
terminal screw
FE
V1000
Ground Wire
Lower-right screw
Ground wire
Drive-side
ground terminal
Screw size:
M3.5 to M6
Option ground
screw FE
Screw size: M3
Screwdriver
V1000
Option ground
terminal (FE)
Ground terminal
screw
Ground wire
Option through-hole
for ground wire
Option back side
V1000
5 Installation Procedure
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
21
17. For IP20/Open-Chassis or IP20/UL Type 1 enclosure models, reattach the bottom cover. Keep the ground wire
inside of the bottom cover when reattaching.
Figure 19
Figure 19 Reattach the Bottom Cover
18. On models CIMR-VBA0006 to BA0018, 2A0008 to 2A0069, and 4A0001 to 4A0038, reattach the
terminal cover.
Refer to Figure 20 and Figure 21 for drive models CIMR-VBA0006 to BA0018, 2A0008 to 2A0020,
and 4A0001 to 4A0011, which require routing the ground wire through the provided notch when reinstalling
the terminal cover.
Figure 20
Figure 20 Reattach the Terminal Cover
(Models CIMR-VBA0006 to BA0018; 2A0008 to 2A0069; 4A0001 to 4A0038)
Figure 21
Figure 21 Terminal Cover Ground Wire Notch
(Models CIMR-VBA0006 to BA0018; 2A0008 to 2A0020; 4A0001 to 4A0011)
IP20/Open-Chassis IP20/UL Type 1 Enclosure
V1000
V1000
Ground wire
routing notch
V1000
5 Installation Procedure
22
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
19. For IP20/Open-Chassis or IP20/UL Type 1 enclosure models, remove the option cover and pass the ground wire
through the inside of the drive bottom cover and into the through-hole for the ground wire at the front of the
option.
Figure 22
Figure 22 Ground Wire Routing
20. For IP20/Open-Chassis or IP20/UL Type 1 enclosure models, attach the option to the drive. Properly seat the
tabs on the left and right sides of the option to the drive case.
Figure 23
Figure 23 Connect the Option
21. For IP20/Open-Chassis or IP20/UL Type 1 enclosure models, connect the ground wire at the option ground
terminal. Tighten the screw to 0.5 to 0.6 Nm or (4.4 to 5.3 in lbs) using an M3 Phillips screwdriver.
Figure 24
Figure 24 Connect the Ground Wire to the Option
Option Cover
V1000
Line up tabs
Line up tabs
V1000
Option ground terminal
V1000
5 Installation Procedure
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
23
22. Connect the PROFINET Cat 5e communication cable to the option modular connector CN1 port 1 or port 2.
Install PROFINET communications cables apart from main-circuit wiring and other electrical and power lines.
Ensure the cable end is firmly connected (see Figure 32).Refer to Communication Cable Specifications on
page 26 for details of installing.
Note:
Do not connect or disconnect the communication cable while the drive is powered up or while the drive is in operation. Failure to
comply may cause a static discharge, which will cause the option card to stop working properly. Cycle power on the drive and
option card to reestablish functionality.
Figure 25
Figure 25 Option Modular Connector CN1 Port 1 and Port 2 for Communication Cable
23. Use the second option modular connector CN1 port to daisy chain a series of drives where applicable.
24. For IP20/Open-Chassis or IP20/UL Type 1 enclosure models, go to Step 31. on page 25.
25. For IP66/UL Type 4X enclosure models, attach the option cover by aligning the tabs with the mounting holes and
seat the front cover into place (see Figure 26).
Figure 26
Figure 26 Attach the Option Cover
26. For IP66/UL Type 4X enclosure models, reattach the lower terminal cover, (on certain models), to the drive by
aligning the left and right tabs and snap into place (see Figure 27).
Figure 27
Figure 27 Reattach the IP66/UL Type 4X Lower Terminal Cover
V1000
Option cover
Mounting tab
Cover
mounting slot
Cover
mounting slot
Ground wire to
drive ground screw
Mounting tab
Cat5E cables
V1000
V1000
5 Installation Procedure
24
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
27. For IP66/UL Type 4X enclosure models, attach the option to the drive by aligning the two mounting tabs on left
and right side of the option with slots on the drive. Plug-in the CN5 connector on the back of the option into the
CN5 connector on the drive. Tighten the screw in the front of the option (see Figure 28).
Figure 28
Figure 28 Attach Option to IP66/UL Type 4X
28. For IP66/UL Type 4X enclosure models, insert the LED operator cable from the front cover into connector CN1
on the drive (see Figure 29).
Figure 29
Figure 29 Insert LED Operator Cable
CN5 Connector
port on drive
CN5 Connector
(underside of option)
Mounting Tab
V1000
CN1 connector
Inside front cover
Insert LED
operator cable
V1000
5 Installation Procedure
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
25
29. Reattach the front cover of the drive using four screws (see Figure 30). Refer to Table 9 on page 25 for
tightening torque specifications.
NOTICE: Damage to Equipment. Take proper precautions when wiring the option so that the front covers will easily fit back onto the
drive. Make sure no cables are pinched between the front covers and the drive when replacing the cover. Failure to comply may result
in damage to circuitry and equipment.
Figure 30
Figure 30 Attach the Front Cover
Table 9 IP66/UL Type 4X Front Cover Installation Screw Size and Tightening Torque
30. For IP66/UL Type 4X enclosure models, go to Step 32. on page 25.
31. For IP20/Open-Chassis or IP20/UL Type 1 enclosure models, attach the option cover by aligning the tabs with
the mounting holes, seat the front cover into place, and tighten the screw on the front.
Figure 31
Figure 31 Attach the Option Cover
Note:
Take proper precautions when wiring the option so that the front covers will easily fit back onto the drive. Make sure no cables
are pinched between the front covers and the drive when replacing the covers.
32. Set drive parameters in Table 10 for proper option performance.
Voltage Class
Model No. CIMR-V
Installation
Screw Size
Tightening Torque
Nm
(lb-in)
Single Phase 200 V Class
BA0001 to BA0012
M5
2.0 to 2.5 (17.7 to 22.1)
Three Phase 200 V Class
2A0001 to 2A0020
M5
2.0 to 2.5 (17.7 to 22.1)
2A0030 to 2A0069
M6
5.4 to 6.0 (47.8 to 53)
Three Phase 400 V Class
4A0001 to 4A0011
M5
2.0 to 2.5 (17.7 to 22.1)
4A0018 to 4A0038
M6
5.4 to 6.0 (47.8 to 53)
Front cover
Front cover screw
V1000
Line up tabs
V1000
5 Installation Procedure
26
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Communication Cable Specifications
Use only PROFINET dedicated communication cable; the Yaskawa warranty does not cover other cable types.
The use of CAT5e or equivalent Shielded Twisted Pair (STP) cable is recommended.
Option Connection Diagram
Figure 32 Wiring Diagram
Communication Cable Topology
The option modular connector CN1 port 1 and port 2 act as a switch to allow for flexibility in cabling topology. For
example, a traditional star network topology may be employed by using a single port on the option board. Alternatively,
a daisy-chained approach may be employed by using both option modular connector ports. This second approach reduces
the requirements of PROFINET switch ports.
Figure 32
Figure 33 Topology Options
GSD Files
To facilitate network implementation, obtain a GSD file from one of the following websites depending on your region:
US: http://www.yaskawa.com
Europe: http://www.yaskawa.eu.com
Japan: http://e-mechatronics.com
Other areas: Check the back cover of these manuals.
<1> Connect the provided ground wire during installation.
V1000
M
U/T1
V/T2
W/T3
R/L1
S/L2
T/L3
SI-EP3/V
PROFINET
Option
FE <1>
PROFINET Master
PROFINET Cable
Motor
Power
PROFINET Cable
V1000
PLC
SWITCH
V1000
V1000
V1000
V1000
V1000
V1000
PLC
STOP
STOP
STOP
STOP
STOP
STOP
SWITCH
V1000
6 Related Drive Parameters
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
27
6
Related Drive Parameters
The parameters in Table 10 set the drive for operation with the option. Confirm proper setting of all parameters in
Table 10 before starting network communications. Refer to the manual packaged with the drive for details on setting
parameters.
Table 10 Related Parameter Settings
No.
(Addr.
Hex)
Name
Description
Values
b1-01
(180)
<1>
Reference 1 Source
Selects the input method for frequency reference.
0: Keypad
1: Analog Input
2: Memobus/Modbus Communications
3: Option PCB
4: Pulse Train Input
Default: 1
Range: 0 to 4
(Set to 3)
b1-02
(181)
<1>
Run Command 1 Source
Selects the input method for the Run command.
0: Keypad
1: Digital Input
2: Memobus/Modbus Communications
3: Option PCB
Default: 1
Range: 0 to 3
(Set to 3)
F6-01
(3A2) <2> Communication Error Selection
Selects drive response when a bUS error is detected during
communications with the option.
0: Ramp to Stop
1: Coast to Stop
2: Fast Stop (Use C1-09)
3: Alarm Only <2>
4: Alarm - Run at d1-04 <2>
5: Alarm - Ramp to Stop
Default: 1
Range: 0 to 53
F6-02
(3A3)
Comm External Fault (EF0) Detect
Selects the condition for external fault detection (EF0).
0: Always detected
1: Detection during run only
Default: 0
Range: 0, 1
F6-03
(3A4)
Comm External Fault (EF0) Select
Selects drive response for external fault input (EF0) detection during
option communications.
0: Ramp to Stop
1: Coast to Stop
2: Fast Stop (Use C1-09)
3: Alarm Only <2>
Default: 1
Range: 0 to 3
F6-07
(3A8)
MultiStep Ref Priority Select
0: MultiStep References Disabled
1: MultiStep References Enabled
Default: 1
Range: 0, 1
F6-08
(36A)
Comm Parameter Reset
@Initialize
Selects whether communication-related parameters F6- and F7-
are set back to original default values when the drive is initialized using
parameter A1-03.
0: No Reset - Parameters retained
1: Reset - Back to factory default
Note: The setting value is not changed even when F6-08 is set to 1 and the
drive is initialized using A1-03.
Default: 0
Range: 0, 1
F6-15
(B5B)
Comm. Option Parameter Upgrade
Selection
Selects whether F6-/F7- communication-related parameters
changed are enabled.
0: Enabled by Cycling the Power
1: Enabled F6-/F7-
2: Disabled F6-/F7-
Note: F6-15 is reset to 0 after setting to 1 or 2.
Default: 0
Range: 0 to 2
F7-01
(3E5)
IP Address 1
Sets the static/fixed IP address.
Parameter F7-01 sets the most significant octet.
Default: 192
Min: 0
Max: 255
F7-02
(3E6)
IP Address 2
Sets the static/fixed IP address.
Parameter F7-02 sets the second most significant octet.
Default: 168
Min: 0
Max: 255
F7-03
(3E7)
IP Address 3
Sets the static/fixed IP address.
Parameter F7-03 sets the third most significant octet.
Default: 1
Min: 0
Max: 255
6 Related Drive Parameters
28
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
F7-04
(3E8)
IP Address 4
Sets the static/fixed IP address.
Parameter F7-04 sets the fourth most significant octet.
Default: 20
Min: 0
Max: 255
F7-05
(3E9)
<7>
Subnet Mask 1
Sets the static/fixed Subnet Mask.
Parameter F7-05 sets the most significant octet.
Default: 255
Min: 0
Max: 255
F7-06
(3EA)
<7>
Subnet Mask 2
Sets the static/fixed Subnet Mask.
Parameter F7-06 sets the second most significant octet.
Default: 255
Min: 0
Max: 255
F7-07
(3EB)
<7>
Subnet Mask 3
Sets the static/fixed Subnet Mask.
Parameter F7-07 sets the third most significant octet.
Default: 255
Min: 0
Max: 255
F7-08
(3EC)
<7>
Subnet Mask 4
Sets the static/fixed Subnet Mask.
Parameter F7-08 sets the fourth most significant octet.
Default: 0
Min: 0
Max: 255
F7-09
(3ED)
<7>
Gateway Address 1
Sets the static/fixed Gateway address.
Parameter F7-09 sets the most significant octet.
Default: 192
Min: 0
Max: 255
F7-10
(3EE)
<7>
Gateway Address 2
Sets the static/fixed Gateway address.
Parameter F7-10 sets the second most significant octet.
Default: 168
Min: 0
Max: 255
F7-11
(3EF)
<7>
Gateway Address 3
Sets the static/fixed Gateway address.
Parameter F7-11 sets the third most significant octet.
Default: 1
Min: 0
Max: 255
F7-12
(3E0)
<7>
Gateway Address 4
Sets the static/fixed Gateway address.
Parameter F7-12 sets the fourth most significant octet.
Default: 1
Min: 0
Max: 255
F7-13
(3F1)
<7>
Address Mode at Startup
Selects how the option address is set.
0: Static <7>
2: DCP
Default: 2
Range: 0, 2
F7-14
(3F2)
Duplex Mode Selection
Selects duplex mode setting.
0: Auto/Auto
1: Half/Half
2: Full/Full
3: Half/Auto
4: Half/Full
5: Auto/Half
6: Auto/Full
7: Full/Half
8: Full/Auto
Default: <7>
Range: 0 to 8
F7-15
(3F3)
<8>
Communication Speed Selection
Sets the communication speed.
0: 10 Mbps (Available only with drive software version PRG: 1012 to
1015)
1: 10 Mbps
100: 100 Mbps
Default: <9>
Range: <9>
F7-23
(3FB)
<10>
Dynamic Output Assembly
Parameter 1
Sets configurable output 1.
Default: 0H
Min.: 0H
Max.: FFFFH
F7-24
(3FC)
<10>
Dynamic Output Assembly
Parameter 2
Sets configurable output 2.
Default: 0H
Min.: 0H
Max.: FFFFH
F7-25
(3FD)
<10>
Dynamic Output Assembly
Parameter 3
Sets configurable output 3.
Default: 0H
Min.: 0H
Max.: FFFFH
F7-26
(3FE)
<10>
Dynamic Output Assembly
Parameter 4
Sets configurable output 4.
Default: 0H
Min.: 0H
Max.: FFFFH
No.
(Addr.
Hex)
Name
Description
Values
6 Related Drive Parameters
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
29
F7-27
(3FF)
<10>
Dynamic Output Assembly
Parameter 5
Sets configurable output 5.
Default: 0H
Min.: 0H
Max.: FFFFH
F7-33
(405)
<10>
Dynamic Input Assembly
Parameter 1
Sets configurable input 1.
Default: 0H
Min.: 0H
Max.: FFFFH
F7-34
(406)
<10>
Dynamic Input Assembly
Parameter 2
Sets configurable input 2.
Default: 0H
Min.: 0H
Max.: FFFFH
F7-35
(407)
<10>
Dynamic Input Assembly
Parameter 3
Sets configurable input 3.
Default: 0H
Min.: 0H
Max.: FFFFH
F7-36
(408)
<10>
Dynamic Input Assembly
Parameter 4
Sets configurable input 4.
Default: 0H
Min.: 0H
Max.: FFFFH
F7-37
(409)
<10>
Dynamic Input Assembly
Parameter 5
Sets configurable input 5.
Default: 0H
Min.: 0H
Max.: FFFFH
H5-11
(43C)
Communications ENTER Function
Selection
Selects whether an Enter command is necessary to change parameter
values via MEMOBUS/Modbus communications.
0: Parameter changes are activated when ENTER command is written
1: Parameter changes are activated immediately without use of ENTER
command
Default: 1
Range: 0, 1
<1> Set b1-02 = 3 to start and stop the drive with the PROFINET master device using serial communications.
Set b1-01 = 3 to control the frequency reference of the drive via the master device.
<2> Setting this parameter to 3 will cause the drive to continue operation after detecting a fault. Take proper measures such as installing an
emergency stop switch when using setting 3.
<3> Available in the V1000 software versions PRG: 1024 and later. Refer to the instruction manual of a specific drive to determine if settings 4 and
5 are available in the drive.
<4> Cycle power for setting changes to take effect.
<5> If F7-13 is set to 0, then all IP Addresses (F7-01 to F7-04) must be unique.
<6> Set F7-01 to F7-12 when F7-13 is set to 0.
<7> Default setting differs by drive software version.
1012 to 1015: 0
≥1016: 1
<8> Set F7-15 when F7-14 is set to 0 or 2.
<9> The setting values differ by drive software version.
1012 to 1015
Default: 0
Range: 0, 10, 100
≥1016
Default: 10
Range: 10, 100
<10> If a value other than 0 is assigned to parameters F7-23 to F7-27 and F7-33 to F7-37 by the drive, that value will take precedent over a value set
by the configuration software. If the value in the drive is 0 (default), the value from the configuration software is used.
No.
(Addr.
Hex)
Name
Description
Values
6 Related Drive Parameters
30
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Table 11 Option Monitors
No.
Name
Description
Range
U6-80 to U6-83
OPT IP ADR1 to 4
Displays IP Address currently available;
• U6 -80: First octet
• U6 -81: Second octet
• U6 -82: Third octet
• U6 -83: Forth octet
0 to 255
U6-84 to U6-87
Online Subnet 1 to 4
Displays subnet currently available;
• U6 -84: First octet
• U6 -85: Second octet
• U6 -86: Third octet
• U6 -87: Forth octet
0 to 255
U6-88 to U6-91
Online Gateway
Displays gateway currently available;
• U6 -88: First octet
• U6 -89: Second octet
• U6 -90: Third octet
• U6 -91: Forth octet
0 to 255
U6-92
Online Speed
Displays CN1 Port 1 link speed currently available.
10, 100
U6-93
Online Duplex
Displays CN1 Port 1 duplex setting currently available.
0: Half, 1: Full
U6-94
Online Speed
Displays CN1 Port 2 link speed currently available.
10, 100
U6-95
Online Duplex
Displays CN1 Port 2 duplex setting currently available.
0: Half, 1: Full
U6-98
First Fault
Displays first option fault. Refer to Option Fault Monitors U6-98
and U6-99 on page 57 for details.
–
U6-99
Current Fault
Displays current option fault. Refer to Option Fault Monitors
U6-98 and U6-99 on page 57 for details.
–
7 PROFINET Messaging
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
31
7
PROFINET Messaging
PROFINET Overview
This section describes the communication profile used between the PROFINET I/O network and the option.
The option supports the PROFIdrive profile. Users can select between the control and status words according to the
PROFIdrive profile or use the Yaskawa-specific control and status words.
PROFIdrive Communication Profile
The Control Word and the Status Word
The contents of the Control Word and the Status Word are detailed in Table 12. and Table 13. respectively. The drive
states are presented in the PROFIdrive State Machine (Figure 34.).
Frequency Reference
The Frequency reference is a 16-bit word containing a sign bit and a 15-bit integer. A negative reference (indicating
reverse direction of rotation) is formed by calculating the two's complement from the corresponding positive reference.
The reference value is the desired output frequency.
Output Frequency
Output Frequency is a 16-bit word containing the current output frequency (U1-02) of the drive.
Table 12 Control Word for PROFIdrive Communication Profile
Bit
Name
Value
Proceed to STATE/Description
0
ON
1
Proceed to READY TO OPERATE.
OFF1
0
Emergency OFF. Proceed to OFF1 ACTIVE; proceed further to READY TO SWITCH
ON unless other interlocks (OFF2, OFF3) are active.
1
OFF2
1
Continue operation (OFF2 inactive).
0
Emergency OFF. Proceed to OFF2 ACTIVE; proceed further to SWITCH ON INHIBIT.
2
OFF3
1
Continue operation (OFF3 inactive).
0
Emergency stop. Proceed to OFF3 ACTIVE; proceed further to SWITCH-ON INHIBIT.
3
OPERATION_
ENABLE
1
Proceed to ENABLE OPERATION.
0
Inhibit operation. Proceed to OPERATION INHIBIT.
4
RAMP_OUT_ ZERO
1
Normal operation. Proceed to RAMP FUNCTION GENERATOR: ENABLE OUTPUT.
0
Stop according to selected stop type.
5
RAMP_HOLD
1
Normal operation.
0
Proceed to RAMP FUNCTION GENERATOR: ENABLE ACCELERATOR. Halt
ramping (Ramp Function Generator output held).
6
RAMP_IN_ ZERO
1
Normal operation. Proceed to OPERATING. Note: This bit is effective only if the
fieldbus interface is set as the source for this signal by drive parameters.
0
Force Ramp Function Generator input to zero.
7
RESET
0 -> 1
Fault reset if an active fault exists. Proceed to SWITCH ON INHIBIT.
0
(Continue normal operation)
8
INCHING_1
–
Inching 1. (Not supported)
9
INCHING_2
–
Inching 2. (Not supported)
10
REMOTE_CMD
1
Network control enabled.
0
Network control disabled.
11 to 15
–
–
Reserved
7 PROFINET Messaging
32
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Table 13 Status Word for the PROFIdrive Communication Profile
Bit
Name
Value
STATE/Description
0
RDY_ON
1
READY TO SWITCH ON.
0
NOT READY TO SWITCH ON.
1
RDY_RUN
1
READY TO OPERATE.
0
OFF1 ACTIVE.
2
RDY_REF
1
ENABLE OPERATION.
0
DISABLE OPERATION.
3
TRIPPED
1
FAULT.
0
No fault.
4
OFF_2_STA
1
OFF2 inactive.
0
OFF2 ACTIVE.
5
OFF_3_STA
1
OFF3 inactive.
0
OFF3 ACTIVE.
6
SWC_ON_INHIB
1
SWITCH-ON INHIBIT ACTIVE.
0
SWITCH-ON INHIBIT NOT ACTIVE.
7
ALARM
1
Warning/Alarm.
0
No Warning/Alarm.
8
AT_SETPOINT
1
OPERATING. Actual value equals reference value (i.e., is within tolerance limits).
0
Actual value differs from reference value (i.e., is outside tolerance limits).
9
REMOTE
1
Drive control location: REMOTE.
0
Drive control location: LOCAL.
10
ABOVE_LIMIT
–
Not supported.
11 to 15
–
–
Reserved
7 PROFINET Messaging
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
33
Figure 33
Figure 34 PROFIdrive State Machine
READY TO
SWITCH ON
7 PROFINET Messaging
34
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Yaskawa Vendor-Specific Control and Status Words
The Control Word and the Status Word
The contents of the Control Word and the Status Word are detailed in Table 14.
Frequency Reference
Frequency Reference is a 16-bit word containing the desired output frequency.
Output Frequency
Output Frequency is a 16-bit word containing the current output frequency of the drive.
Table 14 Yaskawa-Specific Control Word and Status Word
Yaskawa-Specific Control Word
Yaskawa-Specific Status Word
Bit
Description
Bit
Description
0
Run bit
0
Running
1
Reverse run bit
1
Zero Speed
2
EF0
2
Reverse Operation
3
Fault Reset
3
Reset Signal Input Active
4
ComFref
4
At Speed
5
ComCtrl
5
Ready
6
DI3
6
Alarm
7
DI4
7
Fault
8
DI5
8
oPE Fault
9
DI6
9
Uv Return
10
DI7
10
2nd Motor
11
Not Used
11
ZSV
12
Not Used
12
Not Used
13
Not Used
13
Not Used
14
Not Used
14
Net Reference
15
Not Used
15
Net Control
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
35
8
Communication
This section describes the PROFINET IO messaging used in communication with the drive.
For detailed information on PROFINET IO communication, refer to PROFINET specification Application Layer
protocol for decentralized periphery and distributed automation v2.0 available at www.profibus.com.
Introduction to PROFINET IO
PROFINET IO is a fieldbus protocol that enables communication between programmable controllers and distributed
field devices in Ethernet network. The protocol classifies devices into IO controllers, IO supervisors and IO devices,
which have a specific collection of services.
PROFINET IO uses three different communication channels to exchange data. The standard UDP/IP and TCP/IP channel
is used for parameterization and configuration of devices and for acyclic operations. The Real Time (RT) channel is used
for cyclic data transfer and alarms. The third channel, Isochronous Real Time (IRT) channel, is used e.g. in motion
control applications (not implemented in SI-EP3/V).
PROFINET IO devices are structured in slots and sub-slots, which can contain modules and sub-modules
correspondingly. Devices can have almost any number of slots and sub-slots and they can be virtual or real. Device
specific data is represented in slot 0, module and sub-module specific data in subsequent slots and sub-slots.
One of the benefits of PROFINET IO is the diagnostics and alarm mechanism. Every module and sub-module provide
alarm data to the IO controller using the cyclic channel. Diagnostic data can be read non-cyclically from the device by
using record data.
Properties and services of a PROFINET IO device are described in a GSD file that is written in General Station
Description Markup Language (GSDML). GSD file describes the device specific modules and the method of assigning
modules and sub-modules to predefined slots and sub-slots.
PROFINET IO in SI-EP3/V
The decision to use either the PROFIdrive control and status words or the Yaskawa-specific control and status words is
done in a hardware configuration tool (customer supplied). The default value is the Yaskawa-specific format.
SI-EP3/V uses slots 0 and 1. Slot 0 does not have any sub-slots and the attached DAP module represents the device.
Other functional modules and sub-modules described in the GSD file can be assigned to slot 1 and its sub-slots.
• Slot 0 = Device access point (DAP)
• Slot 1, sub-slot 1 = Standard telegram 1, Standard telegram 1 + 5 configurable inputs, outputs, Forty byte IO with 5
configurable input, outputs
The services provided by the SI-EP3/V option can be defined using the F7- parameters in the drive or by using a
configuration tool. To define the service using the F7- parameters, set the parameter to a value other than 0.
If all F7- parameters are set to 0, the value from the configuration tool will be used.
The SI-EP3/V option provides the following services:
• Cyclic messaging in PROFIdrive or Yaskawa-specific mode
• Acyclic parameter access mechanism
• Identification & Maintenance functions (I&M0)
• PROFIdrive parameters
• Diagnostic and alarm mechanism
• Fault buffer mechanism
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Yaskawa SI-EP3/V PROFINET I/O Modules
Std Tgm 1
Table 15 Std Tgm 1 Consume
Table 16 Std Tgm 1 Produce
Std Tgm 1 + 5 PZD
Table 17 Std Tgm 1 + 5 PZD Consume
Table 18 Std Tgm 1 + 5 PZD Produce
Bytes
Description
0
Control Word MSB
1
Control Word LSB
2
Frequency Reference MSB
3
Frequency Reference LSB
Bytes
Description
0
Status Word MSB
1
Status Word LSB
2
Output Frequency MSB
3
Output Frequency LSB
Bytes
Description
0
Control Word MSB
1
Control Word LSB
2
Frequency Reference MSB
3
Frequency Reference LSB
4
Configurable Output 1 MSB
5
Configurable Output 1 LSB
6
Configurable Output 2 MSB
7
Configurable Output 2 LSB
8
Configurable Output 3 MSB
9
Configurable Output 3 LSB
10
Configurable Output 4 MSB
11
Configurable Output 4 LSB
12
Configurable Output 5 MSB
13
Configurable Output 5 LSB
Bytes
Description
0
Status Word MSB
1
Status Word LSB
2
Output Frequency MSB
3
Output Frequency LSB
4
Configurable Input 1 MSB
5
Configurable Input 1 LSB
6
Configurable Input 2 MSB
7
Configurable Input 2 LSB
8
Configurable Input 3 MSB
9
Configurable Input 3 LSB
10
Configurable Input 4 MSB
11
Configurable Input 4 LSB
12
Configurable Input 5 MSB
13
Configurable Input 5 LSB
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
37
Forty Byte IO
Table 19 Forty Byte IO Consume
Bytes
Description
0
Control Word MSB
1
Control Word LSB
2
Frequency Reference MSB
3
Frequency Reference LSB
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
Reserved
9
Reserved
10
Reserved
11
Reserved
12
Analog Output 1 MSB
13
Analog Output 1 LSB
14
Analog Output 2 MSB
15
Analog Output 2 LSB
16
Digital Outputs MSB
17
Digital Outputs LSB
18
Reserved
19
Reserved
20
Reserved
21
Reserved
22
Reserved
23
Reserved
24
Reserved
25
Reserved
26
Reserved
27
Reserved
28
Reserved
29
Reserved
30
Configurable Output 1 MSB
31
Configurable Output 1 LSB
32
Configurable Output 2 MSB
33
Configurable Output 2 LSB
34
Configurable Output 3 MSB
35
Configurable Output 3 LSB
36
Configurable Output 4 MSB
37
Configurable Output 4 LSB
38
Configurable Output 5 MSB
39
Configurable Output 5 LSB
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Table 20 Forty Byte IO Produce
Bytes
Description
0
Status Word MSB
1
Status Word LSB
2
Output Frequency MSB
3
Output Frequency LSB
4
Reserved
5
Reserved
6
PG Count Value MSB
7
PG Count Value LSB
8
Motor Speed MSB
9
Motor Speed LSB
10
Frequency Reference Monitor MSB
11
Frequency Reference Monitor LSB
12
Output Current MSB
13
Output Current LSB
14
Analog Input 1 MSB
15
Analog Input 1 LSB
16
DC Bus Voltage MSB
17
DC Bus Voltage LSB
18
Fault Code MSB
19
Fault Code LSB
20
Alarm Code MSB
21
Alarm Code LSB
22
Output Power MSB
23
Output Power LSB
24
Analog Input 2 MSB
25
Analog Input 2 LSB
26
Digital Inputs MSB
27
Digital Inputs LSB
28
Analog Input 3 MSB
29
Analog Input 3 LSB
30
Configurable Input 1 MSB
31
Configurable Input 1 LSB
32
Configurable Input 2 MSB
33
Configurable Input 2 LSB
34
Configurable Input 3 MSB
35
Configurable Input 3 LSB
36
Configurable Input 4 MSB
37
Configurable Input 4 LSB
38
Configurable Input 5 MSB
39
Configurable Input 5 LSB
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
39
Cyclic Messaging
SI-EP3/V supports cycle times of 8 to 512 ms.
CW: Control Word
SW: Status Word
REF: Reference
ACT: Actual Value
PZD: Configurable inputs and outputs
Yaskawa Acyclic Parameter Access Mechanism
All drive parameters can be read and written under address 0x8000 by performing a read or write with the index value of
the corresponding parameter address in the drive. Refer to the drive Technical Manual for a list of these parameter
addresses.
PROFIdrive Acyclic Parameter Access Mechanism
A PROFIdrive acyclic parameter access mechanism can be used to access PROFIdrive parameters and drive parameters
using an index of 0xB02E and the structure in Figure 26 for write and read requests.
Requests and responses between the IO device and the IO controller or the IO supervisor are transferred with the Record
Data Objects.
Figure 34
Figure 35 PROFIdrive Acyclic Parameter Access Mechanism Structure
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
A write request is first sent containing the parameter request.
If the write request is valid, the SI-EP3/V acknowledges it with request accepted. The master then sends a read request. If
the SI-EP3/V is still busy performing the internal parameter request, it will return a negative response with the error code
“0xB5” (State conflict). In this case, the master repeats the read request until the SI-EP3/V has the PROFIdrive response
data ready.
If the write request is invalid, a negative response is returned with an error code.
Base Mode Parameter Access - Local
The DO-ID field in the Record Data Object request header is not evaluated by the parameter manager. Parameters can be
read through any slot in the configuration.
Table 21 Response Error Codes
Table 22 ErrorCode1 with PNIORW Decoding
Byte
Value and Meaning
ErrorCode
0xDF (Error Write)
0xDE (Error Read)
ErrorDecode
0x80 (PNIORW) ErrorCode1 decoded according to Table 22. ErrorCode2 is 0.
0x81 (PNIO) ErrorCode1 and ErrorCode2 decoded according to Table 22.
ErrorCode1
Error class and error code (Refer to Table 22).
ErrorCode2
Not described
Error class
Meaning
Error Code
0 to 9
(Reserved)
–
10 (0x0A)
Application
0 = Read error
1 = Write error
2 = Module failure
3 to 7 = Reserved
8 = Version conflict
9 = Feature not supported
10 to 15 = User-specific
11 (0x0B)
Access
0 = Invalid index
1 = Write length error
2 = Invalid slot
3 = Type conflict
4 = Invalid area
5 = State conflict
6 = Access denied
7 = Invalid range
8 = Invalid parameter
9 = Invalid type
10 to 15 = User-specific
12 (0x0C)
Resource
0 = Read constraint conflict
1 = Write constraint conflict
2 = Resource busy
3 = Resource unavailable
4 to 7 = Reserved
8 to 15 = User-specific
13 to 15
User-specific
–
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
41
Read block is used in read requests and responses. Write block is used in write requests and responses. The request
consists of unique identifiers for the connection, addressing information and length of the record data. The response also
contains two additional fields for transferring information.
Table 23 Structure of the Read and Write Blocks
Data block contains PROFIdrive specific request or response header.
Table 24 PROFIdrive Request Header
Field(s)
Description
Range
Type
Service
Request or Response service.
Request (0x00)
Response (0x80)
UI8
Operation
Read or Write operation.
Write (0x08) Read (0x09)
UI8
Block length
Length of the block.
0 to 0xFFFF
UI16
ARUUID
Identifier
- time low
- time mid
- time high and version - clock - node
–
UI32
UI16
UI16
Octet[2]
Octet[6]
API
Application Process Identifier
Device Access Point (0x0000)
UI32
PROFIdrive (0x3A00)
Slot
Slot of the Module Access Point (MAP/PAP)
0x01
UI16
Sub-slot
Sub-slot of the Module Access Point (MAP/PAP)
0x01
UI16
Padding
2 bytes
Index
Index of the Record Data Object
0x0001 to 0x7FFF
0xB02E
UI16
Data length
Length of the data block
0 to 0xFFFFFFFF
UI32
Additional value 1
(response only)
Field for transferring additional data
–
UI16
Additional value 2
(response only)
Field for transferring additional data
–
UI16
Padding
24 bytes for request, 20 bytes for response.
Data block
Used only with write request and read response.
Field(s)
Description
Range
Byte/ Word
Request Reference
Unique identification set by the master. Changed for
each new request.
1 to 255
Byte
Request ID
Request type for the issued block.
Request Parameter (0x01)
Change Parameter (0x02)
Byte
DO-ID
To be set to 0x01.
0 to 255
Byte
No. of
Parameters
Number of parameters that are present in the request.
1
Byte
Attribute
Type of object being accessed.
Value (0x10)
Byte
No. of Elements
Number of array elements accessed or length of string
accessed. Set to 0 if non-array parameters are used.
0, 1 to 234
Byte
Parameter
Index (group)
Address of the PROFIdrive parameter that is being
accessed. Also “1” is allowed by SI-EP3/V to access
drive parameters.
Drive parameter group when accessing drive
parameters.
1 to 65535
Word
Subindex (parameter)
<1> Only when Request ID is 0x02 (Change Parameter). The Format, Number of Values, and Value Fields are repeated for other parameters.
Addresses the first array element of the parameter.
Drive parameter number when accessing drive
parameters.
0 to 65535
Word
Format <1>
Refer to Table 26 for details.
–
Byte
Number of Values <1>
Number of values following.
1
Byte
Values <1>
The values of the request. In case of odd number of
bytes, a zero byte is appended to ensure the word
structure of the telegram.
Varies based on value
See Format Field
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Table 25 PROFIdrive Response Header
Table 26 Data Types for Format Field
Table 27 PROFIdrive Parameter Request Error Codes
Field(s)
Description
Range
Response Reference
Mirrored from the request.
1 to 255
Response ID
Response from the slave. In the event that requested services fail, a
“not acknowledged” (NAK) response will be indicated.
Request Param OK (0x01) Request Param NAK
(0x81) Change Param OK (0x02) Change Param NAK
(0x82)
DO-ID
To be set to 1.
0 to 255
No. of Parameters
<1> Only when Request ID is 0x01 (Request Parameter OK). The Format, Number of Values, and Value Fields are repeated for other parameters.
Number of parameters that are present in the response.
1 to 37
Format <1>
Refer to Table 26 for details.
–
Number of Values <1>
Number of values following.
0 to 234
Values <1>
The values of the request.
When there is an odd number of bytes, a zero byte is appended to
ensure the word structure of the telegram.
Varies based on value
Code
Type
0x00
(Reserved)
0x01 to 0x36
Standard data types
0x37 to 0x3F
(Reserved)
0x40
Zero
0x41
Byte
0x42
Word
0x43
Double word
0x44
Error
0x45 to 0xFF
(Reserved)
Error #
Meaning
Used at
0x00
Impermissible parameter number
Access to unavailable parameter.
0x01
Parameter value cannot be changed
Change access to a parameter value that cannot be changed.
0x02
Low or high limit exceeded
Change access with value outside the limits.
0x03
Invalid subindex
Access to unavailable subindex.
0x04
No array
Access with subindex to non-indexed parameter.
0x05
Incorrect data type
Change access with value that does not match the data type of the parameter.
0x06
Setting not permitted (can only be reset)
Change access with value unequal to 0 when this is not permitted.
0x07
Description element cannot be changed
Change access to a description element that cannot be changed.
0x09
No description data available
Access to unavailable description (parameter value is available).
0x0B
No operation priority
Change access rights without rights to change parameters.
0x0F
No text array available
Access to text array that is not available (parameter value is available).
0x11
Request cannot be executed because of
operating mode
Access is temporarily not possible for reasons outside scope of these instructions.
0x14
Value impermissible
Change access with a value that is within limits but is not permissible for other
long-term reasons (parameter with defined single values).
0x15
Response too long
The length of the current response exceeds the maximum transmittable length.
0x16
Parameter address impermissible
Illegal value or value that is not supported for the attribute, number of elements,
parameter number or sub-index, or a combination.
0x17
Illegal format
Write request: Illegal format or format of parameter data that is not supported.
0x18
Number of values inconsistent
Write request: Number of values of parameter data does not match number of elements
at the parameter address.
0x19
DO nonexistent
Request to DO, which does not exist.
0x65 to 0xFF Manufacturer-specific
–
0x65
Vendor-specific error
Vendor-specific error.
0x66
Request not supported
Request not supported.
0x67
Communication error
Request cannot be completed because of communication error.
0x6F
Time-out error
Request aborted due to time-out.
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
43
Parameter Data Transfer Examples
The following example shows how parameter data is transferred using the acyclic parameter access mechanism's READ
and WRITE.
Example 1: Reading a drive parameter
To read a Yaskawa Drive parameter, use the PNU of 1 and the actual address of the parameter in the SubIndex.
Write Request (Read Parameter Value)
Positive Read Response to Read Request
Negative Response to PROFIdrive Read Request
0x78
PZD map failure
Parameter cannot be mapped to PZD (size mismatch or non-existent).
0x79
PZD memory failure
Parameter cannot be mapped to PZD (out of memory).
0x7A
Multiple PZD map
Parameter cannot be mapped to PZD (multiple PZD write).
0x8C
Set torque mode error
Cannot change mode to TORQUE (frequency is used).
0x90
Illegal Request ID
The request ID of the response is illegal.
Error #
Meaning
Used at
01 01 B0 2E 08 05 81 01 01 44 01 00 14
(44H = Error)
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
PROFIdrive Profile-Specific Parameters
PROFIdrive parameters contain data of the drive in standard form. The table below describes the supported PROFIdrive
parameters.
Fault Buffer Mechanism
PROFIdrive profile has a mechanism that can store five fault situations to PROFIdrive parameters. Fault and diagnostic
data, like fault number and fault code can be accessed simultaneously with only one subindex. The mechanism consists
of two PROFIdrive parameters:
• PNU944: Fault message counter
• PNU947: Fault numbers according to value in U2-01
Parameter
R/W
Data type
Description
922
R
Unsigned16
Telegram selection
944
R
Unsigned16
Fault message counter
947
R
Array [5] Unsigned16
Fault number. (coded according to DRIVECOM profile) Subindex Contents, see
parameter 945.
964
R
Array [6] Unsigned16
Device identification Subindex Contents 0 Manufacturer 1 Device type 2 Version 3
Firmware date (year) 4 Firmware date (day/month) 5 Number of Drive Objects (DO)
965
R
Octet String2
Profile number of this device. 0328h = Profile 3, Version 40
967
R
Unsigned16
Control word (CW)
968
R
Unsigned16
Status word (SW)
972
R/W
Unsigned16
Software reset Value Description 0 No action 1 Power-cycle PROFINET IO module
The parameter must do a zero-to-one transition and the motor must be stopped.
977
R/W
Unsigned16
Stores parameters to non-volatile memory Value Description 0 No action 1 Stores
parameters The parameter must do a zero-to-one transition and the motor must be
stopped.
61000
R
VisibleString24
Name of station
61001
R
Unsigned32
IP of station
61002
R
Array [6] Unsigned8
MAC of station
61003
R
Unsigned32
Default gateway of station
61004
R
Unsigned32
Subnet mask of station
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
45
Option High Priority Alarm Codes
These codes are transmitted as Manufacturer Specific Diagnostic high priority alarms that can be seen in the PLC
configuration software. These high priority codes are the same codes that appear in the drive manual, except with an
offset of 0x1000.
Table 28 PROFINET Option High Priority Alarm Codes
Drive Alarm
Code
(Hex) <1>
Description
Corrective Action
1000
None
–
1001
DC Bus Fuse Open (PUF)
Output Transistor Failure. Replace the drive
1002
DC Bus Undervolt (Uv1)
Input power fluctuation too large
1003
CTL PS Undervolt (Uv2)
Cycle drive power and replace drive if fault continues
1004
MC Answerback (Uv3)
Cycle drive power and replace drive if fault continues
1005
Short Circuit (SC)
• Check drive wiring
• Cycle drive power and replace drive if fault continues.
1006
Ground Fault (GF)
Check for motor and/or cable damage
1007
Over Current (oC)
Check motor, motor load and accel/decel rates
1008
DC Bus Overvolt (oV)
• Check incoming voltage
• Check deceleration time
1009
Heatsink Overtemp (oH)
• Check ambient temperature
• Check drive cooling fan
100A
Heatsink Max Temp (oH1)
Check drive cooling fan
100B
Motor Overload (oL1)
• Check the load, accel/decel and cycle times
• Check motor rated current (E2-01)
100C
Inv Overload (oL2)
• Check the load, accel/decel and cycle times
• Check drive rating
100D
Overtorque Det 1 (oL3)
• Check L6-02 and L6-03 settings
• Check system mechanics
100E
Overtorque Det 2 (oL4)
• Check L6-05 and L6-06 settings
• Check system mechanics
100F
DynBrk Transistor (rr)
Cycle drive power and replace drive if fault continues
1010
DynBrk Resistor (rH)
Check load, operating speed and deceleration time
1011
External Fault 3 (EF3)
• Multifunction digital input set to external fault
• Circuit at terminal is closed
1012
External Fault 4 (EF4)
1013
External Fault 5 (EF5)
1014
External Fault 6 (EF6)
1015
External Fault 7 (EF7)
1016
None
–
1017
Heatsink Fan (FAn)
Check drive cooling fan
1018
Overspeed Det (oS)
• Check reference and reference gain
• Check F1-08 and F1-09 settings
1019
Speed Deviation (dEV)
• Check load, accel/decel times and system mechanics
• Check F1-10 and F1-11 settings
101A
None
-
101B
Input Phase Loss (PF)
Excessive input voltage fluctuation
101C
Output Phase Loss (LF)
• Check for broken wire/loose terminals
• Check motor rating
101D
None
–
101E
Operator Disconnected (oPr)
Reconnect the digital operator
101F
EEPROM R/W Error (Err)
Cycle drive power and replace drive if fault continues
1020
None
–
1021
Comm Error (bUS)
• Check network cable connections.
• Check 24 Vdc power supply voltage
1022
Check option installation and connections.
1023
Cycle drive power and replace option or drive if fault continues.
1024
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Option Low Priority Alarm Codes
These codes are transmitted as Manufacturer Specific Diagnostic low priority alarms that can be seen in the PLC
configuration software. These low priority codes are the same codes that appear in the drive manual, except with an
offset of 0x1000.
Table 29 PROFINET Option Low Priority Alarm Codes
1025
Out of Control (CF)
• Check motor parameters
• Auto-tune
1027
External Fault 0 (EF0)
• Check PLC program
• Check MI switch setting
• Check option LEDs for fault indication
<1> Drive error code is stored in MEMOBUS/Modbus address 0080 Hex.
Drive Alarm
Code
(Hex) <1>
<1> Drive error code is stored in MEMOBUS/Modbus address 0080 Hex.
Description
Drive Alarm
Code
(Hex)
<1>
Description
0401
Undervoltage (Uv)
0422
Motor Overheat (oH3)
0402
Overvoltage (ov)
0427
PID Feedback Loss (FbL)
0403
Heatsink Overheat (oH)
0428
PID Feedback Loss (FbH)
0404
Drive Overheat (oH2)
042A
Drive Disabled (dnE)
0405
Overtorque 1 (oL3)
0431
Option Watchdog Error (E5)
0406
Overtorque 2 (oL4)
0432
Option Station Address Setting Error (AEr)
0407
Rum Command Input Error (EF)
0433
Option Comm. Cycle Setting Error (CyC)
0408
Drive Baseblock (bb)
0434
High Current Alarm (HCA)
0409
External Fault 3, input terminal S3 (EF3)
0435
Cooling Fan Maintenance Time (LT-1)
040A
External Fault 3, input terminal S4 (EF4)
0436
Capacitor Maintenance Time (LT-2)
040B
External Fault 3, input terminal S5 (EF5)
0438
Option EEPROM Error (EEP)
040C
External Fault 3, input terminal S6 (EF6)
0439
External Fault (input terminal S1) (EF1)
040D
External Fault 3, input terminal S7 (EF7)
043A
External Fault (input terminal S2) (EF2)
040F
Cooling Fan Error (FAn)
043B
Safe Disable Input (HbbF)
0410
Overspeed (oS)
043C
Safe Disable Input (Hbb)
0411
Excessive Speed Deviation (dEv)
043D
Mechanical Weakening Detection 1 (oL5)
0414
MEMOBUS/Modbus Comm. Error (CE)
043E
Mechanical Weakening Detection 2 (UL5)
0415
Option Communication Error (bUS)
043F
PLC Alarm (PA1)
0416
Serial Comm. Transmission Error (CALL)
0440
PLC Alarm (PA2)
0417
Motor Overload (oL1)
0441
Output Voltage Detection Fault (voF)
0418
Drive Overload (oL2)
0442
IGBT Maintenance Time (90%) (TrPC)
041A
Option Card External Fault (EF0)
0443
Soft Charge Bypass Relay Maintenance Time (LT-3)
041B
Motor Switch Command Input during Run (rUn)
0444
IGBT Maintenance Time (50%) (LT-4)
041D
Serial Comm. Transmission Error (CALL)
0445
Braking Transistor Overload (boL)
041E
Undertorque Detection 1 (UL3)
0448
Motor Overheat (NTC Input) (oH5)
041F
Undertorque Detection 2 (UL4)
0449
DriveWorksEZ Alarm (dWAL)
0420
MEMOBUS/Modbus Test Mode Fault (SE)
–
–
Drive Alarm
Code
(Hex) <1>
Description
Corrective Action
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
47
Identification and Maintenance Functions (I&M)
The purpose of the I&M functions is to provide support for the customer during commissioning, parametrization and
repair of the module. SI-EP3/V supports I&M function 0, which can be accessed using the Record data object's read
request.
Structure of the I&M functions is described in the following tables.
Table 30 I&M0 Device Identification (Read-Only)
Diagnostic and Alarms
SI-EP3/V has mechanisms for sending alarms and saving diagnostics data to fault buffer. Alarm will be triggered if the
host or drive has faults in communication or operation. There are three types of faults:
Alarm Mechanism
When a fault or alarm situation occurs in the drive, the SI-EP3/V adapter will send an alarm notification, which the
master station must acknowledge. Refer to Table 31 for details.
Table 31 Alarm Notification
Function
Record Data Index
I&M0
0xAFF0
Content
Size
Description
Header
10 bytes
–
Vendor ID
2 bytes
PROFINET Vendor ID of Yaskawa, which is 0x019F
Order ID
20 bytes
Order number of the SI-EP3/V adapter kit (SI-EP3)
Serial number
16 bytes
Serial number of the adapter
Hardware revision
2 bytes
Hardware revision of the SI-EP3/V adapter
Software revision
4 bytes
Revision of the software
Revision counter
2 bytes
Revision number
Profile ID
2 bytes
PROFIdrive (0x3A00)
Profile specific type
2 bytes
No profile specific type (0x0000)
I&M version
2 bytes
Version is 1.1 (0x0101)
Supported I&M functions
2 bytes
I&M0 is supported (0x0001)
Fault
API/Slot/Sub-slot
Channel Error Type
Drive Fault
0x3A00 / 1 / 1
A fault declared in drive
Attribute
Description
BlockHeader
–
AlarmType
PROFINET specific alarm type
API
0x3A00 (PROFIdrive profile)
SlotNumber
Slot number of the Drive Object (DO)
SubslotNumber
Sub-slot number of the sub-slot to which the diagnosis object is related
ModuleIdentNumber
Module Ident number of the DO
SubmoduleIdentNumber
0xFFFF
AlarmSpecifier
Diagnosis type
UserStructureIdentifier
0x8000 (Channel Diagnosis Data)
ChannelNumber
0
ChannelProperties
0x0800 Diagnosis Appears
0x1000 Diagnosis Disappears
ChannelErrorType
Error code of drive fault or drive alarm
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
9 Web Interface
9
Web Interface
The web server interface to the drive option through port 80 allows management of diagnostic information through a
standard web browser. The web page is a Java applet that creates a tabbed web page. The available tabs include:
• Main Tab
• Drive Status Tab
• Network Tab
• Doc links Tab
• Email Alerts Tab
• Parameter Access Tab <1>
• Configuration Tab <1>
• Custom Tab
Access the web server interface by typing the IP address of the SI-EP3/V option in a web browser address.
Example: "http://192.168.1.20"
The SI-EP3/V IP Address is available using drive digital operator to access Option Monitors U6-80 to U6-83.
Refer to Table 11 for details.
Main Tab
The Main tab shows basic option information such as IP address, MAC address, and firmware version.
Figure 35
Figure 36 Main Tab View
Note:
The initial password is yaskawa. To change the password, open the Configuration Tab.
<1> PCs must have Java SE 6 Update 14 or later installed to view the web pages. PCs without Java will display web pages with limited features.
1016
CIMR-AU4A0009
9 Web Interface
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
49
Drive Status Tab
The Drive Status tab shows basic I/O information and drive state information.
Figure 36
Figure 37 Drive Status Tab View
Network Tab
The Network tab shows the status of the option network traffic and the status of open I/O connections.
Figure 37
Figure 38 Network Tab View
9 Web Interface
50
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Table 32 Network Monitor Descriptions
Note:
Cumulative counters are reset when the power supply is cycled.
Doc Links Tab
The Doc links tab contains links to the option documentation on the Yaskawa website.
Figure 38
Figure 39 Doc Links Tab View
Network Monitor
Explanation
Msg Tx OK
Cumulative number of messages transmit successfully from SI-EP3/V.
Msg Rx OK
Cumulative number of messages received successfully to SI-EP3/V.
Current Connections
Current number of open connections.
Msg Tx Dropped
Cumulative number of messages dropped due to output network buffer being full and unable to hold the
new message.
Msg Rx Dropped
Cumulative number of messages dropped due to input network buffer being full and unable to hold the
new message.
Collisions
Cumulative number of collisions (half duplex only) reported by the MAC/PHY (Media Access Control/
Physical Layer).
Msg Tx Errors
Cumulative number of transmit errors reported by the MAC/PHY (Media Access Control/Physical Layer).
Msg Rx Errors
Cumulative number of receive errors reported by the MAC/PHY (Media Access Control/Physical Layer).
Tx Retry
Cumulative number of retransmits due to busy medium reported by the MAC/PHY (Media Access
Control/Physical Layer).
SI-EP3
9 Web Interface
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
51
Email Alerts Tab
The Email Alerts tab allows the user to configure four Email Fault/Alarm conditions. When the condition is true, one
email will be sent to the provided email address. Another email will not be sent until the condition becomes false and
then true again. A 30-second timer prevents emails from being sent when conditions reoccur immediately after being
removed. The timer helps limit the amount of emails sent regarding the same intermittent condition and helps to reduce
network traffic by reducing emails about reoccurring errors.
Figure 39
Figure 40 Email Alerts Tab View
Procedure: Conditional Email Set-up
1.
Define the condition that will trigger the email by selecting a monitor parameter, a comparator, and a value. Set
the conditions to send alerts from the “Condition” drop-down selection. If choosing only one condition and no OR
or AND are needed, set the “OR/AND” drop-down selection to “NotUsed”.
2.
Enter the email address where the alert will be sent.
3.
Enter the message that will appear in the email contents.
4.
Enter the email subject.
5.
Click the “Email Active” check box to enable the alert.
Clicking “Save to device” will save the entered information into the option.
Clicking “Cancel and reload” will cancel any pending edits and display the most recently saved settings from the option
board.
9 Web Interface
52
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Parameter Access Tab
The Parameter Access tab allows the user to read and write parameters from the drive. Write access is restricted until a
valid password is entered.
Figure 40
Figure 41 Parameter Access Tab View
The MEMOBUS/Modbus address for the drive parameter being accessed must be entered in hexadecimal. The number
must begin with “0x” to signify hexadecimal.
Clicking “Read” will load and display the current value of the given MEMOBUS/Modbus Address. Clicking “Set” will
save the given value to the given MEMOBUS/Modbus address.
After a “Read” or “Set” command is given, Status will display “Waiting” while the action is being carried out, then
“Complete” is displayed when finished.
Configuration Tab
The Configuration tab sets web page behavior parameters. Access is restricted unless a valid password is entered.
Figure 41
Figure 42 Configuration Tab View
sample@sample.
9 Web Interface
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
53
Security Login
Enter a valid password and click “Log in”. The button text will change to “Log out” and the status will change to
“Logged in”.
Note:
The default security password is “yaskawa”.
This password can be changed in the “Change Password” section of the tab. Entering a valid password allows access to
the settings in the Configuration tab, Email Alerts tab, and the Parameter Access tab.
Change Password
To change the password, enter the new password in the “New Password:” and “Confirm Password:” text boxes then click
“Change password”. The Status display will change to “Idle” then “Changing Password” then “Password Changed”. If
the passwords in the two text boxes do not match, the Status will display “Passwords don’t match”.
Option Card
The values displayed in the various tabs are refreshed at the rate defined in the “Applet Refresh Rate (ms)” text box.
Enter values in the range of 1000 ms to 65.535 seconds.
Parameter Security can be enabled or disabled by clicking one of the radio buttons. When “Disabled” is selected, no
password is necessary and all functions in the web pages will be available. When “Enabled” is selected, a valid password
must be entered to edit email settings and to write parameters.
Email Settings
The “Email Server IP” text box must contain the IP address of the email server. The subnet address is configured in drive
parameters F7-05 through F7-08. The configured email alerts will use the server at this address when sending emails.
Enter the email server port in the “Email Port” text box.
The value in the “From’ Email Address” text box identifies the origin of the email alerts to the recipient.
Click “Submit Email Parameters” to save the email settings to the option.
Click “Save Configuration Parameters to Flash” to save the entered values from this tab into non-volatile memory. These
values will then be remembered after cycling power.
General Settings
Click “Save Option Card Parameters” to save the Applet Refresh Rate and the Parameter Security settings to the option.
9 Web Interface
54
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Custom Tab
The Custom tab displays a selection of quick setting parameters.
Figure 42
Figure 43 Custom Tab View
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
55
10
Troubleshooting
Drive-Side Error Codes
Drive-side error codes appear on the drive keypad. Table 33 lists causes of the errors and possible corrective actions.
Refer to the drive Technical Manual for additional error codes that may appear on the drive digital operator.
Faults
Both bUS (Option Communication Error) and EF0 (Option Card External Fault) can appear as either an alarm or as a
fault. When a fault occurs, the keypad ALM LED remains lit. When an alarm occurs, the keypad ALM LED flashes.
Check the following items first when an error code occurs on the drive:
• Communication cable connections
• Make sure the option is properly installed to the drive
• Operation status of the controller program and controller CPU
• Did a momentary power loss interrupt communications?
Table 33 Fault Displays, Causes, and Possible Solutions
Keypad Display
Fault Name
bUS
Option Communication Error
• After establishing initial communication, the connection was lost.
• Only detected when the run command frequency reference is assigned to the option
(bl-01 = 3 or bl-02 = 3).
Cause
Possible Solution
No signal was received from the PLC.
• Check for faulty wiring.
• Correct any wiring problems.
Faulty communications wiring.
An existing short circuit or
communications disconnection.
Check disconnected cables and short circuits and repair as needed.
A data error occurred due to electric
interference.
• Counteract noise in the control circuit, main circuit, and ground wiring.
• If a magnetic contactor is identified as a source of noise, install a surge absorber to the contactor coil.
• Use only recommended cables or other shielded line. Ground the shield on the controller side or the
drive input power side.
• Separate all communication wiring from drive power lines. Install an EMC noise filter to the drive
power supply input.
• Counteract noise in the master controller (PLC).
The option is not properly connected to
the drive.
Reinstall the option.
Option is damaged.
If there are no problems with the wiring and the error continues to occur, replace the option.
Keypad Display
Fault Name
EF0
Option Card External Fault
The alarm function for an external device has been triggered.
Cause
Possible Solution
An external fault was received from the
PLC.
1. Remove the cause of the external fault.
2. Reset the external fault input from the PLC.
Problem with the PLC program.
Check the PLC program.
Keypad Display
Fault Name
oFA00
Option Card Connection Error
Option is not properly connected.
Cause
Possible Solution
The option card installed into option
port A is incompatible with the drive.
Connect the option to the correct option port.
Keypad Display
Fault Name
oFA01
Option Card Fault
Option is not properly connected.
Cause
Possible Solution
The option connected to option port A
was changed during run.
De-energize the drive and plug the option into the drive according to Installation Procedure on page 13.
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
Minor Faults and Alarms
Keypad Display
Fault Name
oFA03
Option fault
Option self-diagnostics error
Cause
Possible Solution
The option card connection to port
CN5-A is faulty.
1. Turn off the power.
2. Check if the option is properly plugged into the option port.
3. Replace the option if the fault continues to occur.
Keypad Display
Fault Name
oFA04
Option fault
Option flash write mode
Cause
Possible Solution
The option card connection to port
CN5-A is faulty.
1. Turn off the power.
2. Check if the option is properly plugged into the option port.
3. Replace the option if the fault continues to occur.
Keypad Display
Fault Name
to
oFA30 to oFA43
Option Card Connection Error
Communication ID error.
Cause
Possible Solution
The option card connection to port
CN5-A is faulty.
1. Turn off the power.
2. Check if the option is properly plugged into the option port.
3. Replace the option if the fault continues to occur.
Keypad Display
Minor Fault Name
CALL
Serial communication transmission error
Communication is not established.
Cause
Possible Solution
Minor Fault
(H2- = 10)
Communication wiring is faulty.
• Check for wiring errors.
• Correct the wiring.
YES
An existing short circuit or communications
disconnection
Check disconnected cables and short circuits and repair as needed.
Programming error on the master side.
Check communications at start-up and correct programming errors.
Communication circuitry is damaged.
• Perform a self-diagnostics check
• If the problem continues, replace either the control board or the
entire drive. For instructions on replacing the control board, contact
Yaskawa or your nearest sales representative.
Termination resistor of the MEMOBUS/
Modbus communications is not enabled.
Set DIP switch S2 to the ON position to enable the termination
resistor on a drive located at the end of a network line.
Keypad Display
Minor Fault Name
CyPo
Cycle Power to Active Parameters
Comm. Option Parameter Not Upgraded
Cause
Possible Solution
Minor Fault
(H2- = 10)
Drive is not compatible with the option
software version.
Turn off the power and upgrade the communication option
parameters.
Note: An alarm is triggered when the option software version is
earlier or an incompatible option is installed to the drive.
YES
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
57
Option Fault Monitors U6-98 and U6-99
The option can declare error/warning conditions via drive monitor parameters on the drive digital operator as shown in
Table 34.
Table 34 Option Fault Monitor Descriptions
Two drive monitor parameters, U6-98 and U6-99 assist in network troubleshooting:
• U6-98 displays the first declared fault since the last power cycle. U6-98 is only cleared upon drive power-up.
• U6-99 displays the present option SI-EP3/V status. U6-99 is cleared upon a network-issued fault reset and upon
power-up.
If another fault occurs while the original fault is still active, parameter U6-98 retains the original fault value and U6-99
stores the new fault status value.
Fault Condition
Fault Declared
Status Value
(U6-98/U6-99)
Description
No Fault
N/A
0
No faults.
Force Fault
EF0
3
Network sent a message to force this node to the fault state.
Network Link Down
bUS
1300
No network link to option board.
Network Failure
bUS
1301
Connection with PLC Timeout.
Default MAC Address
None
1303
Factory default MAC Address programmed into the option. Return for
reprogramming.
No IP Address
None
1304
No IP Address has been programmed into the option.
No Station Name
None
1305
No Station Name has been programmed into the option.
Config Error
None
1306
Configuration error on power-up.
Init. Failure
None
1307
Initialize error on power-up.
Permanent
Communication Loss
bUS
1308
Fatal error in MAC/PHY hardware, requires power cycle to recover.
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
11 European Standards
11
European Standards
Figure 43
Figure 44 CE Mark
The CE mark indicates compliance with European safety and environmental regulations. It is required for engaging in
business and commerce in Europe.
European standards include the Machinery Directive for machine manufacturers, the Low Voltage Directive for
electronics manufacturers, and the EMC guidelines for controlling noise.
This option displays the CE mark based on the EMC guidelines.
EMC Guidelines: 2014/30/EU
Drives used in combination with this option and devices used in combination with the drive must also be CE certified and
display the CE mark. When using drives displaying the CE mark in combination with other devices, it is ultimately the
responsibility of the user to ensure compliance with CE standards. Verify that conditions meet European standards after
setting up the device.
EMC Guidelines Compliance
This option is tested according to European standards EN 61800-3:2004+A1:2012 and complies with EMC guidelines.
The CE marking is declared based on the harmonized standards.
EMC Guidelines Installation Conditions
Verify the following installation conditions to ensure that other devices and machinery used in combination with this
option and drives also comply with EMC guidelines:
1.
Use dedicated shield cable for the option and external device (encoder, I/O device, master), or run the wiring
through a metal conduit.
2.
Keep wiring as short as possible and ground the largest possible surface area of the shield to the metal panel
according to Figure 46.
Figure 44
Figure 45 Ground Area
A – Braided shield cable
C – Cable clamp
(conductive)
B – Metal panel
C
B
A
11 European Standards
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
59
Option Installation for CE Compliance: Model SI-/V
Figure 45
Figure 46 Option Installation for CE Compliance
L1
L2
L3
L1
L2
L3
R
S
T
Drive
EMC filter
SI-��/V
Communication
option
Master
Enclosure panel
Three
phase
power
supply
Cable clamp
V1000
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
12 Specifications
12
Specifications
Table 35 Option Specifications
Items
Specifications
Model
SI-EP3/V
Option Conformance
Passed PROFINET Conformance Class A
Connector Type
Dual RJ45 8-pin Shielded Twisted Pair Cat 5e cable
Physical Layer Type
Isolated Physical Layer
TCP Protocol Transformer Isolated
IP Address Setting
Programmable from drive keypad or network
Communication Speed
Programmable from drive keypad or network:
10/100 Mbps, auto-negotiate.
Number of Connections
1 PLC connection, 1 supervisor connection, 2 web page connections
Duplex Mode
Half-forced, Auto-negotiate, Full-forced
Address Startup Mode
Static, DCP
Ambient Temperature
-10 °C to +50 °C (14°F to 122°F)
Humidity
Up to 95% RH (no condensation)
Storage Temperature
-20 °C to +60 °C (-4 °F to 140°F) (allowed for short-term transport of the product)
Area of Use
Indoors and free from:
• Oil mist, corrosive gas, flammable gas, and dust
• Radioactive materials or flammable materials, including wood
• Harmful gas or fluids
• Salt
• Direct sunlight
• Falling foreign objects
Altitude
1000 m (3280 ft.) or lower
PROFINET Functions
PROFINET IO with PROFIdrive profile
Configurable I/O in cyclic messages
Drive diagnostic alarms
I&M0
YASKAWA ELECTRIC SIEP C730600 70B V1000 Option SI-EP3/V Technical Manual
61
Revision History
Revision dates and manual numbers appear on the bottom of the back cover.
Date of Publication
Revision
Number
Section
Revised Content
June 2016
<1>
Front cover
Revision: Format
All
Revision: Reviewed and corrected entire documentation.
Chapter 5
Revision: Installation procedure of the option
Back cover
Revision: Address, Format
March 2015
−
−
First edition
MANUAL NO. SIEP C730600 70B <1>
Published in Japan June 2016
Date of publication
Revision number
V1000
DRIVE CENTER (INVERTER PLANT)
2-13-1, Nishimiyaichi, Yukuhashi, Fukuoka, 824-8511, Japan
Phone: +81-930-25-2548 Fax: +81-930-25-3431
http://www.yaskawa.co.jp
YASKAWA ELECTRIC CORPORATION
New Pier Takeshiba South Tower, 1-16-1, Kaigan, Minatoku, Tokyo, 105-6891, Japan
Phone: +81-3-5402-4502 Fax: +81-3-5402-4580
http://www.yaskawa.co.jp
YASKAWA AMERICA, INC.
2121, Norman Drive South, Waukegan, IL 60085, U.S.A.
Phone: +1-800-YASKAWA (927-5292) or +1-847-887-7000 Fax: +1-847-887-7310
http://www.yaskawa.com
YASKAWA ELÉTRICO DO BRASIL LTDA.
777, Avenida Piraporinha, Diadema, São Paulo, 09950-000, Brasil
Phone: +55-11-3585-1100 Fax: +55-11-3585-1187
http://www.yaskawa.com.br
YASKAWA EUROPE GmbH
Hauptstraβe 185, 65760 Eschborn, Germany
Phone: +49-6196-569-300 Fax: +49-6196-569-398
http://www.yaskawa.eu.com E-mail: [email protected]
YASKAWA ELECTRIC KOREA CORPORATION
9F, Kyobo Securities Bldg., 97, Uisadang-daero, Yeongdeungpo-gu, Seoul, Korea 07327
Phone: +82-2-784-7844 Fax: +82-2-784-8495
http://www.yaskawa.co.kr
YASKAWA ELECTRIC (SINGAPORE) PTE. LTD.
151, Lorong Chuan, #04-02A, New Tech Park, 556741, Singapore
Phone: +65-6282-3003 Fax: +65-6289-3003
http://www.yaskawa.com.sg
YASKAWA ELECTRIC (THAILAND) CO., LTD.
59, 1st-5th Floor, Flourish Building, Soi Ratchadapisek 18, Ratchadapisek Road, Huaykwang, Bangkok, 10310, Thailand
Phone: +66-2-017-0099 Fax: +66-2-017-0799
http://www.yaskawa.co.th
YASKAWA ELECTRIC (CHINA) CO., LTD.
22F, One Corporate Avenue, No.222, Hubin Road, Shanghai, 200021, China
Phone: +86-21-5385-2200 Fax: +86-21-5385-3299
http://www.yaskawa.com.cn
YASKAWA ELECTRIC (CHINA) CO., LTD. BEIJING OFFICE
Room 1011, Tower W3 Oriental Plaza, No. 1, East Chang An Ave.,
Dong Cheng District, Beijing, 100738, China
Phone: +86-10-8518-4086 Fax: +86-10-8518-4082
YASKAWA ELECTRIC TAIWAN CORPORATION
9F, 16, Nanking E. Rd., Sec. 3, Taipei, 104, Taiwan
Phone: +886-2-2502-5003 Fax: +886-2-2505-1280
http://www.yaskawa.com.tw
YASKAWA INDIA PRIVATE LIMITED
#17/A, Electronics City, Hosur Road, Bangalore, 560 100 (Karnataka), India
Phone: +91-80-4244-1900 Fax: +91-80-4244-1901
http://www.yaskawaindia.in
In the event that the end user of this product is to be the military and said product is to
be employed in any weapons systems or the manufacture thereof, the export will fall
under the relevant regulations as stipulated in the Foreign Exchange and Foreign
Trade Regulations. Therefore, be sure to follow all procedures and submit all relevant
documentation according to any and all rules, regulations and laws that may apply.
Specifications are subject to change without notice for ongoing product modifications
and improvements.
© 2016 YASKAWA ELECTRIC CORPORATION
Published in Japan June 2016
MANUAL NO. SIEP C730600 70B <1>-0
16-4-16
PROFINET
YASKAWA AC Drive-V1000 Option
Technical Manual