WUNDER SA.BI.SRL EN USER MANUAL

960A R150A RG200 REV.10 15/01/2017 1 www.wunder.it PROFESSIONAL MECHANICAL MDD SCALE MOD. 960A R150A RG200A USER MANUAL Read this manual carefully before using the instrument INDEX 2. GENERAL RULES……………………………………………………………………………………………………………………………….. PAGE 2 3. SAFETY……………………………………………………………………………………………………………………………………………… PAGE 2 4. TECHNICAL SPECIFICATION………………………………………………………………………………………………………………. PAGE 3 5. INSTRUCTION FOR USE ……………………………………………………………………………………………………………………. PAGE 3 6. MAINTENANCE AND ASSISTANCE……………………………………………………………………………………………………… PAGE 5 7. CONFORMITY…………………………………………………………………………………………………………………………………… PAGE 5 8. IDENTIFICATION LABELS.......................................................................................................................... PAGE 5 9 SCRAPPING AND WASTE DISPOSAL ………………………………………………………………………………………………….. PAGE 6 10. WARRANTY………………………………………………………………………………………………………………………………………. PAGE 6 11. ASSEMBLY-USE MECHANICAL TELESCOPIC HEIGHT METER (OPTIONAL)……………………………………………. PAGE 7 By choosing the WUNDER mod. 960A or R150A or RG200A professional mechanical scale, you have purchased a high precision instrument. Since over 40 years WUNDER has placed its experience at the service of health. This instrument is compliant with national standards in hospitals and clinics with medical class I with measurement function and is calibrated in conformity with accuracy class IIII. The instrument is characterized by the possibility of fixing the electronic terminal to the weighing platform by means of a column or else installing the terminal autonomously.

WUNDER SA.BI.SRL EN USER MANUAL

960A R150A RG200 REV.10 15/01/2017 2 The instrument is equipped with a dual LCD electronic terminal with triple reading to simultaneously view Weight, Height. and BMI 2. GENERAL RULES Carefully read this manual before using the instrument as it supplies important indications concerning OPERATING SAFETY AND MAINTENANCE. The descriptions and illustrations supplied in this manual are not binding. WUNDER reserves the right to modify its products as deemed convenient in order to approve them without being committed to update this publication. Conventions: The following symbols have been used in this manual: 0476 EC TYPE APROVAL FOR MEDICAL USE METROLOGICAL CERTIFICATION ACCURACY CLASS ASSISTANCE WARRANTY CERTIFICATE WARNING! PLACED BEFORE DETERMINING PROCEDURES. COMPLIANCE FAILURE CAN HARM THE OPERATOR OR PATIENT OR DAMAGE THE PRODUCT 3. SAFETY WARNINGS! Operators must read this manual carefully, comply with the instructions it contains and become familiar with the correct use and maintenance procedures of the instrument. • Retain this manual for consultation and as a help in staff training • Do not overload the instrument beyond its maximum capacity • Do not apply loads abruptly. • Do not press the keys with sharp or pointed objects • Do not try to open the instrument. • Do not remove seals from the instrument. • Unplug the instrument before cleaning it • Do not place the instrument in water or other liquids • Perform maintenance and subsequent metric verifications regularly

WUNDER SA.BI.SRL EN USER MANUAL

960A R150A RG200 REV.10 15/01/2017 3 4. THECHNICAL SPECIFICATION Model 960A R150A RG200A Capacity 150kg 150 kg 100-200kg Division 1000g 1000 g 500-1000g Height Rod 65-200cm- 2~6.6FT: ±1cm Height Rod 60-200cm- 2~6.6FT : ±1cm Manifacture WUNDER SA.BI.SRL Trezzo sull’Adda (MI)- Italy MDD OIML Class IIII Unit weight kg Operation temperature da +10°C a +40°C 5. INSTRUCTIONS FOR USE 960A R150A column RG200A column The instrument is fully ready for use without accessories to assemble. -Instructions manual The instrument is fully ready for use without accessories to assemble. Possible accessories: - Height rod 65-200cm; - Wheels for transport. - Instructions manual The instrument is fully ready for use without accessories to assemble. Possible accessories: -Telescopic height rod 60-200cm; -Wheels for transport. - Instructions manual. 960A Key R150A Key RG200A Key 1. Head with analog dial 2. Footboard covered with rubber 3. Base 4. Weight indicator 5. Zero adjusting screw 1. Head with analog dial 2. Footboard covered with rubber 3. Base 4. Weight indicator 5. Zero adjusting screw 6. Column 1. Head with analog dial 2. Footboard covered with rubber 3. Base 4. Weight indicator 5. Zero adjusting screw 6. Column

WUNDER SA.BI.SRL EN USER MANUAL

960A R150A RG200 REV.10 15/01/2017 4 ONLY WITH SUPPLY OF HEIGHT ROD 7. Height rod with support bracket (accessory) 8. Telescopic height rod (accessory). 9. Transport wheels kit (accessory on request) Note: the height measuring rod support bracket for the R150A model is already fixed on the column. ONLY WITH SUPPLY OF HEIGHT ROD 7. Height rod with support bracket (accessory) 8. Telescopic height rod (accessory). 9. Transport wheels kit (accessory on request) Note: the height measuring rod support bracket for the RG200A model is already fixed on the column. 960A Preparing for use R150A Preparing for use RG200A Preparing for use 1.Overturn the instrument: remove the red clamp and loosen the red wing screw to unlock the lever mechanism 1.Overturn the instrument: remove the red clamp and loosen the red wing screw to unlock the lever mechanism 1.Overturn the instrument: remove the red clamp and loosen the red wing screw to unlock the lever mechanism 2. 960A 2. R150A 2. RG200A 2. Place the instrument on a flat surface for a reliable weight measurement.

WUNDER SA.BI.SRL EN USER MANUAL

960A R150A RG200 REV.10 15/01/2017 5 3 3 3 3. Make sure that the weight index (hand) is at zero. If it is not positioned correctly at zero manually act with the adjusting screw located behind the device head. 4. Step onto the base (footboard) of the scale and read the weight indicated by the hand. 6. MAINTENANCE AND ASSISTANCE For better and longer duration of the product it should receive thorough general cleaning periodically. The instrument must be cleaned with a soft cloth moistened with water or neutral detergent, without using solvents or abrasive substances. If the instrument remains idle for a long period, remove the batteries from the terminal. During shipping, make sure not to subject the instrument to blows or excessive mechanical stress. In case of repairs or assistance, contact your dealer or an authorised service centre contacting [email protected] or [email protected]. 7. CONFORMITY WUNDER MODEL 960A or R150A or RG200 MECHANICAL PROFESSIONAL SCALE SERIAL N°.............................................. We hereby certify that this instrument has been inspected and has successfully passed the functional test. It complies with the following standards and directives: 2009/23/CE; 93/42/CE; EN45501 8 .IDENTIFICATION LABELS

WUNDER SA.BI.SRL EN USER MANUAL

960A R150A RG200 REV.10 15/01/2017 6 9. SCRAPPING AND WASTE DISPOSAL 1. Contact the competent authority for the waste weight disposal. 2. When you decide to no longer use this item, we recommend making it unusable. We also recommend making those parts which could be sources of danger harmless 10. WARRANTY This certificate must be kept until the warranty has expired. It must be presented together with the invoice, tax receipt or delivery note providing the name of the dealer and date of purchase whenever a technical intervention is required. Otherwise the user will lose any warranty rights. The warranty takes effect from the date of purchase and is valid during the entire period foreseen by the current catalogue/pricelist. By warranty we mean the replacement or repair free of charge of parts making up the appliance which, at the discretion of the manufacturer, are deemed faulty from the origin; Wunder therefore has the faculty of repairing or replacing the item. The warranty does not cover: • shipping faults, damage caused by falls, carelessness or tampering • damage caused by incapability of using the appliance and of its improper use • damage caused by an insufficient or inadequate electrical system or alterations resulting from environmental, climatic or other types of conditions • damage due to incorrect installation of the appliance and repairs carried out by unauthorised personnel • Interventions at home for convenience controls or presumed defects • Routine maintenance and that which can be considered normal wear from use • consumables such as: power supplies, batteries, keyboards, plates, wheels, heads, rolls, load cells faulty due to blows or overloads Service can also be refused when the appliance has been changed or transformed in any way. In case of interventions at one's home, the customer must pay the fixed fee; if however the appliance is repaired at an authorised Wunder Service Centre, expenses and relative travel risk are borne by the user. Wunder will not be held liable for damage of any nature caused directly or indirectly to persons, animals or objects resulting from failure to comply with all the instructions indicated in this manual or anyway resulting from improper use. The Court of Bergamo has jurisdiction in case of any dispute

WUNDER SA.BI.SRL EN USER MANUAL

960A R150A RG200 REV.10 15/01/2017 7 11. ASSEMBLING-USING THE HEIGHT ROD (OPTIONAL) FOR THE R150A- RG200A MODEL Using the mechanical telescopic height rod WARNINGS! TO MEASURE THE HEIGHT THE PATIENT MUST STEP ONTO THE SCALE FOOTBOARD RG200A: manual telescopic height rod Figure 1: in the packaging the height rod support is already assembled on the instrument. Simply secure the height rod with the screw Figure 1a-1b: secure the height measuring rod to the black abs support by tightening the screw in the height rod hole Fig. 1 Fig. 1a Fig. 1b USING THE TELESCOPIC HEIGHT ROD Measurements higher than 131 cm Measurements lower than 130 cm 1 Raise the headrest lever 1 Lower the headrest lever and press the central black clamp 2 Position horizontally 2 While holding down the black clamp, lower the headrest lever 3 Lower the rod to where the headrest lever touches the patient's head. The height can be read at point "A" 3 Lower the rod to where the headrest lever touches the patient's head. The height can be read at point "B"