ABB 2CSYD0201B Installation Manual

Text of the manual

1 GENERAL INFORMATION

1.1 Disclaimer All information in this document has been carefully selected and checked however ABB S.p.A. is not liable for any printing errors or technical inaccuracy. ABB S.p.A. reserves the right to improve or change the products described in this user manual at any time and without any advanced notice. Moreover, it

2 GENERAL DESCRIPTION

The outdoor dual IR detector enables to control buildings and areas from outside, and it can be installed both on a wall and on a pole. Thanks to two IR sensors, of which one can be adjusted, it is possible to detect people and to avoid false alarms caused by little animals or cars passing by. The detector is equipped wi

The installation procedure encompasses the following steps:

1) Device fixing. 2) Programming 3) Adjustment. 4) Completion and test. 3.1 Device fixing INSTRUCTIONS RELEVANT TO POSITIONING The device can be installed on a wall or on a pole, far from electromagnetic sources (e.g. electricity meters, electric engines). The detector

The detection of an intrusion attempt occurs only when both IR sensors are

stimulated. Figure 2 graphically summarizes how the detector operates. Figure 2 Sensors can be horizontally adjusted from 45 to 135 degrees. The detection area is set to 90 degrees and it can be masked. The coverage area of the lower sensor can be vertically adjusted.

Other Security Sensors Manuals