Zebra LS2208 Reference Manual

Text of the manual

LS2208 Product Reference Guide

No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice. The software is provided strictly on an “as is” basis. All software, including firmware, furnished to the user is on a licensed basis. We grant to the user a non-transferable and non-exclusive license to use each software or firmware program delivered hereunder (licensed program). Except as noted below, such license may not be assigned, sublicensed, or otherwise transferred by the user without our prior written consent. No right to copy a licensed program in whole or in part is granted, except as permitted under copyright law. The user shall not modify, merge, or incorporate any form or portion of a licensed program with other program material, create a derivative work from a licensed program, or use a licensed program in a network without our written permission. The user agrees to maintain our copyright notice on the licensed programs delivered hereunder, and to include the same on any authorized copies it makes, in whole or in part. The user agrees not to decompile, disassemble, decode, or reverse engineer any licensed program delivered to the user or any portion thereof. Zebra reserves the right to make changes to any product to improve reliability, function, or design. Zebra does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any patent right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Zebra products might be used. An implied license exists only for equipment, circuits, and subsystems contained in Zebra products. Warranty For the complete hardware product warranty statement, go to: http://www.zebra.com/warranty.

Changes to the original manual are listed below:

Change Date Description -01 Rev A 3/2003 Initial release. -02 Rev A 10/2003 Updated with additional bar codes and various other changes. -03 Rev A 1/2007 Updated service information, added parameter bar codes for Bookland ISBN, new UPC supplemental decode options, report software version, report MIMIC version, report Synapse cable, COM port, prefix/suffix value. -04 Rev A 9/2007 Motorola rebranding, changed Set Length(s) for MSI parameter default to 4-55, changed RSS references to GS1 DataBar. -05 Rev A 10/2007 Added bar codes for "Timeout Between Decodes" to User Preferences. -06 Rev A 5/2008 Updated service information, removed IBM XT bar code and keyboard from Keyboard Wedge chapter, add French Belgian country codes, added note regarding Code ID and No Read, added Send Pause and Comma bar codes to ADF chapter. -07 Rev A 7/2010 Corrected the Send Alt @ parameter number and added the Send Alt 2 parameter, updated the default interfaces to Keyboard Wedge and USB, removed patent and regulatory information, updated web addresses, Scan1232 chapter and Feedback chapter. -08 Rev A 4/2012 Updated all URLs; updated supported keyboards in Chapter 1; updated 123Scan2 chapter; updated service information. -09 Rev A 10/2012 Updated ambient light tolerance; updated table 3-3 (added scanner emulation column); added Wand support note. -10 Rev A 4/2015 Zebra rebranding -11 Rev A 7/2016 Updated Advance Data Formatting Chapter. -12 Rev A 6/2017 Changed HID Keyboard Emulation option to USB HID Keyboard Changed USB OPOS Hand-Held option to OPOS (IBM Hand-held with Full Disable) Added Note to USB Device Type Updated 123Scan chapter Changed GS1 DataBar-14 to GS1 DataBar Omnidirectional

Table of Contents

About This Guide Introduction.................................................................................................................... xiii Chapter Descriptions ..................................................................................................... xiii Notational Conventions.................................................................................................. xiv Related Documents ....................................................................................................... xv Service Information........................................................................................................ xv Chapter 1: Getting Started Introduction ................................................................................................................... 1-1 Unpacking Your Scanner .............................................................................................. 1-2 Setting Up the Scanner ................................................................................................. 1-3 Installing the Interface Cable .................................................................................. 1-3 Connecting Power (if required) ............................................................................... 1-4 Configuring Your Scanner ....................................................................................... 1-4 Connecting a Synapse Cable Interface .................................................................. 1-5 Removing the Interface Cable ................................................................................ 1-5 Chapter 2: Scanning Introduction ................................................................................................................... 2-1 Beeper Definitions ........................................................................................................ 2-2 LED Definitions ............................................................................................................. 2-3 Scanning in Hand-Held Mode ....................................................................................... 2-4 Aiming ........................................................................................................................... 2-5 Decode Zone ................................................................................................................ 2-6 Scanning in Hands-Free Mode ..................................................................................... 2-7 Assembling the Stand ............................................................................................. 2-7 Mounting the Stand (optional) ................................................................................. 2-8 Scanning in Hands-Free Mode ..................................................................................... 2-9 Scanning in the Hands-Free Mode ......................................................................... 2-9

LS2208 Product Reference Guide

Chapter 3: Maintenance and Technical Specifications Introduction ................................................................................................................... 3-1 Maintenance ................................................................................................................. 3-1 Troubleshooting ............................................................................................................ 3-2 Technical Specifications ............................................................................................... 3-4 Scanner Signal Descriptions ......................................................................................... 3-6 Chapter 4: User Preferences Introduction ................................................................................................................... 4-1 Scanning Sequence Examples ..................................................................................... 4-1 Errors While Scanning .................................................................................................. 4-2 User Preferences Default Parameters .......................................................................... 4-2 User Preferences .......................................................................................................... 4-3 Set Default Parameter ............................................................................................ 4-3 Beeper Tone ........................................................................................................... 4-4 Beeper Volume ....................................................................................................... 4-5 Power Mode .................................................................................................................. 4-6 Laser On Time ........................................................................................................ 4-7 Beep After Good Decode ........................................................................................ 4-8 Timeout Between Decodes ........................................................................................... 4-9 Chapter 5: Keyboard Wedge Interface Introduction ................................................................................................................... 5-1 Connecting a Keyboard Wedge Interface ..................................................................... 5-2 Keyboard Wedge Default Parameters .......................................................................... 5-3 Keyboard Wedge Host Types ....................................................................................... 5-4 Keyboard Wedge Host Types ................................................................................. 5-4 Keyboard Wedge Country Types (Country Codes) ................................................ 5-5 Ignore Unknown Characters ................................................................................... 5-7 Keystroke Delay ...................................................................................................... 5-8 Intra-Keystroke Delay ............................................................................................. 5-9 Alternate Numeric Keypad Emulation ..................................................................... 5-9 Caps Lock On ......................................................................................................... 5-10 Caps Lock Override ................................................................................................ 5-10 Convert Wedge Data .............................................................................................. 5-11 Function Key Mapping ............................................................................................ 5-12 FN1 Substitution ..................................................................................................... 5-13 Send Make and Break ............................................................................................ 5-13 Keyboard Maps ....................................................................................................... 5-14 ASCII Character Set ..................................................................................................... 5-16 Chapter 6: RS-232 Interface Introduction ................................................................................................................... 6-1 Connecting an RS-232 Interface .................................................................................. 6-2 RS-232 Default Parameters .......................................................................................... 6-3 RS-232 Host Parameters .............................................................................................. 6-4 RS-232 Host Types ................................................................................................. 6-6

Table of Contents

vii Baud Rate ............................................................................................................... 6-8 Parity ....................................................................................................................... 6-10 Stop Bit Select ........................................................................................................ 6-12 Data Bits ................................................................................................................. 6-12 Check Receive Errors ............................................................................................. 6-13 Hardware Handshaking .......................................................................................... 6-14 Software Handshaking ............................................................................................ 6-16 Host Serial Response Time-out .............................................................................. 6-18 RTS Line State ........................................................................................................ 6-19 Beep on ....................................................................................................... 6-19 Intercharacter Delay ................................................................................................ 6-20 Nixdorf Beep/LED Options ...................................................................................... 6-21 Ignore Unknown Characters ................................................................................... 6-21 ASCII Character Set ..................................................................................................... 6-22 Chapter 7: USB Interface Introduction ................................................................................................................... 7-1 Connecting a USB Interface ......................................................................................... 7-1 USB Default Parameters .............................................................................................. 7-3 USB Host Parameters .................................................................................................. 7-4 USB Device Type .................................................................................................... 7-4 USB Country Keyboard Types (Country Codes) .................................................... 7-6 USB Keystroke Delay ............................................................................................. 7-9 USB CAPS Lock Override ...................................................................................... 7-10 USB Ignore Unknown Characters ........................................................................... 7-11 Emulate Keypad ...................................................................................................... 7-12 USB Keyboard FN 1 Substitution ............................................................................ 7-12 Function Key Mapping ............................................................................................ 7-13 Simulated Caps Lock .............................................................................................. 7-13 Convert Case .......................................................................................................... 7-14 ASCII Character Set ..................................................................................................... 7-15 Chapter 8: IBM 468X/469X Interface Introduction ................................................................................................................... 8-1 Connecting to an IBM 468X/469X Host ........................................................................ 8-2 IBM Default Parameters ............................................................................................... 8-3 IBM 468X/469X Host Parameters ................................................................................. 8-4 Port Address ........................................................................................................... 8-4 Convert Unknown to Code 39 ................................................................................. 8-5 Chapter 9: Wand Emulation Interface Introduction ................................................................................................................... 9-1 Connecting Using Wand Emulation .............................................................................. 9-2 Wand Emulation Default Parameters ........................................................................... 9-3 Wand Emulation Host Parameters ............................................................................... 9-4 Wand Emulation Host Types .................................................................................. 9-4 Leading Margin (Quiet Zone) .................................................................................. 9-5

LS2208 Product Reference Guide

Polarity .................................................................................................................... 9-6 Ignore Unknown Characters ................................................................................... 9-6 Convert All Bar Codes to Code 39 .......................................................................... 9-7 Convert Code 39 to Full ASCII ............................................................................... 9-7 Chapter 10: Undecoded Scanner Emulation Interface Introduction ................................................................................................................... 10-1 Connecting Using Undecoded Scanner Emulation ....................................................... 10-2 Undecoded Scanner Emulation Default Parameters .................................................... 10-3 Undecoded Scanner Emulation Host ............................................................................ 10-4 Undecoded Scanner Emulation Host Parameters ........................................................ 10-5 Beep Style ............................................................................................................... 10-5 Parameter Pass-Through ........................................................................................ 10-6 Convert Newer Code Types .................................................................................... 10-7 Module Width .......................................................................................................... 10-7 Convert All Bar Codes to Code 39 .......................................................................... 10-8 Code 39 Full ASCII Conversion .............................................................................. 10-8 Transmission Timeout ............................................................................................. 10-9 Ignore Unknown Characters ................................................................................... 10-10 Leading Margin ....................................................................................................... 10-11 Check For Decode LED .......................................................................................... 10-12 Chapter 11: 123Scan Introduction ................................................................................................................... 11-1 Communication with 123Scan ...................................................................................... 11-1 123Scan Requirements ................................................................................................ 11-1 123Scan Information ..................................................................................................... 11-2 Scanner SDK, Other Software Tools, and Videos ........................................................ 11-2 Chapter 12: Symbologies Introduction ................................................................................................................... 12-1 Scanning Sequence Examples ..................................................................................... 12-1 Errors While Scanning .................................................................................................. 12-1 Symbology Default Parameters .................................................................................... 12-2 UPC/EAN ...................................................................................................................... 12-5 Enable/Disable UPC-A/UPC-E ............................................................................... 12-5 Enable/Disable UPC-E1 .......................................................................................... 12-6 Enable/Disable EAN-13/EAN-8 ............................................................................... 12-7 Enable/Disable Bookland EAN ............................................................................... 12-8 Decode UPC/EAN/JAN Supplementals .................................................................. 12-9 User-Programmable Supplementals ....................................................................... 12-12 UPC/EAN/JAN Supplemental Redundancy ............................................................ 12-12 Transmit UPC-A/UPC-E/UPC-E1 Check Digit ........................................................ 12-13 UPC-A Preamble .................................................................................................... 12-14 UPC-E Preamble .................................................................................................... 12-15 UPC-E1 Preamble .................................................................................................. 12-16 Convert UPC-E to UPC-A ....................................................................................... 12-17

Table of Contents

ix Convert UPC-E1 to UPC-A ..................................................................................... 12-18 EAN-8/JAN-8 Extend .............................................................................................. 12-18 Bookland ISBN Format ........................................................................................... 12-19 UPC/EAN Security Level ........................................................................................ 12-20 UCC Coupon Extended Code ................................................................................. 12-21 Code 128 ...................................................................................................................... 12-22 Enable/Disable Code 128 ....................................................................................... 12-22 Enable/Disable UCC/EAN-128 ............................................................................... 12-22 Enable/Disable ISBT 128 ........................................................................................ 12-23 Code 39 ........................................................................................................................ 12-24 Enable/Disable Code 39 ......................................................................................... 12-24 Enable/Disable Trioptic Code 39 ............................................................................ 12-24 Convert Code 39 to Code 32 .................................................................................. 12-25 Code 32 Prefix ........................................................................................................ 12-25 Set Lengths for Code 39 ......................................................................................... 12-26 Code 39 Check Digit Verification ............................................................................ 12-27 Transmit Code 39 Check Digit ................................................................................ 12-27 Code 39 Full ASCII Conversion .............................................................................. 12-28 Code 39 Buffering (Scan & Store) .......................................................................... 12-29 Code 93 ........................................................................................................................ 12-32 Enable/Disable Code 93 ......................................................................................... 12-32 Set Lengths for Code 93 ......................................................................................... 12-33 Code 11 ........................................................................................................................ 12-34 Code 11 .................................................................................................................. 12-34 Set Lengths for Code 11 ......................................................................................... 12-35 Code 11 Check Digit Verification ............................................................................ 12-36 Transmit Code 11 Check Digits .............................................................................. 12-37 Interleaved 2 of 5 (ITF) ................................................................................................. 12-38 Enable/Disable Interleaved 2 of 5 ........................................................................... 12-38 Set Lengths for Interleaved 2 of 5 ........................................................................... 12-39 I 2 of 5 Check Digit Verification ............................................................................... 12-40 Transmit I 2 of 5 Check Digit ................................................................................... 12-41 Convert I 2 of 5 to EAN-13 ...................................................................................... 12-41 Discrete 2 of 5 (DTF) .................................................................................................... 12-42 Enable/Disable Discrete 2 of 5 ................................................................................ 12-42 Set Lengths for Discrete 2 of 5 ............................................................................... 12-43 Chinese 2 of 5 ............................................................................................................... 12-44 Enable/Disable Chinese 2 of 5 ................................................................................ 12-44 Codabar (NW - 7) ......................................................................................................... 12-45 Enable/Disable Codabar ......................................................................................... 12-45 Set Lengths for Codabar ......................................................................................... 12-46 CLSI Editing ............................................................................................................ 12-47 NOTIS Editing ......................................................................................................... 12-47 MSI ............................................................................................................................... 12-48 Enable/Disable MSI ................................................................................................ 12-48 Set Lengths for MSI ................................................................................................ 12-49 MSI Check Digits .................................................................................................... 12-50 Transmit MSI Check Digit(s) ................................................................................... 12-50 MSI Check Digit Algorithm ...................................................................................... 12-51

LS2208 Product Reference Guide

GS1 DataBar (Formerly RSS, Reduced Space Symbology) ........................................ 12-52 GS1 DataBar ........................................................................................................... 12-52 Convert GS1 DataBar to UPC/EAN ........................................................................ 12-53 Redundancy Level ........................................................................................................ 12-54 Redundancy Level 1 ............................................................................................... 12-54 Redundancy Level 2 ............................................................................................... 12-54 Redundancy Level 3 ............................................................................................... 12-55 Redundancy Level 4 ............................................................................................... 12-55 Security Level ............................................................................................................... 12-56 Security Level 0 ...................................................................................................... 12-56 Security Level 1 ...................................................................................................... 12-56 Security Level 2 ...................................................................................................... 12-56 Security Level 3 ...................................................................................................... 12-57 Bi-directional Redundancy ...................................................................................... 12-58 Intercharacter Gap Size .......................................................................................... 12-58 Report Version .............................................................................................................. 12-59 Report MIMIC Version .................................................................................................. 12-59 Report Synapse Cable .................................................................................................. 12-59 Chapter 13: Miscellaneous Scanner Options Introduction ................................................................................................................... 13-1 Scanning Sequence Examples ..................................................................................... 13-2 Errors While Scanning .................................................................................................. 13-2 Miscellaneous Default Parameters ............................................................................... 13-2 Miscellaneous Scanner Parameters ............................................................................. 13-3 Transmit Code ID Character ................................................................................... 13-3 Prefix/Suffix Values ................................................................................................. 13-4 Scan Data Transmission Format ............................................................................ 13-4 FN1 Substitution Values ......................................................................................... 13-6 Transmit “No Read” Message ................................................................................. 13-6 Synapse Interface ................................................................................................... 13-7 Chapter 14: Advanced Data Formatting Introduction ................................................................................................................... 14-1 Appendix A: Standard Default Parameters Appendix B: Programming Reference Symbol Code Identifiers ................................................................................................ B-1 AIM Code Identifiers ..................................................................................................... B-2

Table of Contents

xi Appendix C: Sample Bar Codes Code 39 ........................................................................................................................ C-1 UPC/EAN ...................................................................................................................... C-1 UPC-A, 100 % ......................................................................................................... C-1 EAN-13, 100 % ....................................................................................................... C-2 Code 128 ...................................................................................................................... C-2 Interleaved 2 of 5 .......................................................................................................... C-2 GS1 Databar Omnidirectional ....................................................................................... C-2 Appendix D: Numeric Bar Codes Numeric Bar Codes ...................................................................................................... D-1 0, 1, 2 ...................................................................................................................... D-1 3, 4, 5, 6 .................................................................................................................. D-2 7, 8, 9 ...................................................................................................................... D-3 Cancel ........................................................................................................................... D-3 Index

About This Guide

Introduction The LS2208 Product Reference Guide provides general instructions for setting up, operating, maintaining and troubleshooting the LS2208. Chapter Descriptions Topics covered in this guide are as follows: • Chapter 1, Getting Started provides a product overview and unpacking instructions. • Chapter 2, Scanning describes parts of the scanner, beeper and LED definitions, and how to use the scanner in hand-held and hands-free modes. • Chapter 3, Maintenance and Technical Specifications provides information on how to care for the scanner, troubleshooting, and technical specifications. • Chapter 4, User Preferences provides programming bar codes for selecting user preference features for the scanner. • Chapter 5, Keyboard Wedge Interface provides information for setting up the scanner for Keyboard Wedge operation. • Chapter 6, RS-232 Interface provides information for setting up the scanner for RS-232 operation. • Chapter 7, USB Interface provides information for setting up the scanner for USB operation. • Chapter 8, IBM 468X/469X Interface provides information for setting up the scanner with IBM 468X/469X POS systems. • Chapter 9, Wand Emulation Interface provides information for setting up the scanner for Wand emulation operation. • Chapter 10, Undecoded Scanner Emulation Interface provides information for setting up the scanner for Undecoded Scanner emulation operation. • Chapter 11, 123Scan (PC based scanner configuration tool) provides the bar code to scan to communicate with the 123Scan program.

LS2208 Product Reference Guide

• Chapter 12, Symbologies describes all symbology features and provides programming bar codes for selecting these features for the scanner. • Chapter 13, Miscellaneous Scanner Options includes features frequently used to customize how data transmits to the host device. • Chapter 14, Advanced Data Formatting (ADF) provides a reference to customize scanned data before transmitting to the host. • Appendix A, Standard Default Parameters provides a reference to all host devices and miscellaneous scanner defaults. • Appendix B, Programming Reference provides a table of AIM code identifiers, ASCII character conversions, and keyboard maps. • Appendix C, Sample Bar Codes includes sample bar codes of various code types. • Appendix D, Numeric Bar Codes includes the numeric bar codes to scan for parameters requiring specific numeric values. Notational Conventions The following conventions are used in this document: • Italics are used to highlight chapters and sections in this and related documents • Bold text is used to highlight parameter and bar code names • Bullets (•) indicate: • Action items • Lists of alternatives • Lists of required steps that are not necessarily sequential • Sequential lists (e.g., those that describe step-by-step procedures) appear as numbered lists. • Throughout the programming bar code menus, asterisks (*) are used to denote default parameter settings. *Baud Rate 9600 Feature/Option * Indicates Default NOTE This symbol indicates something of special interest or importance to the reader. Failure to read the note will not result in physical harm to the reader, equipment or data. CAUTION This symbol indicates that if this information is ignored, the possibility of data or material damage may occur. WARNING! This symbol indicates that if this information is ignored the possibility that serious personal injury may occur.

About This Guide xv

Related Documents The LS2208 Series Quick Reference Guide, p/n 72-58807-xx, provides general information to help you get started with the scanner. It includes basic set-up and operation instructions. The latest version of this guide and all guides, are available at: http://www.zebra.com/support. Service Information If you have a problem using the equipment, contact your facility's technical or systems support. If there is a problem with the equipment, they will contact the Support Center at: http://www.zebra.com/support. When contacting support, please have the following information available: • Serial number of the unit • Model number or product name • Software type and version number We respond to calls by e-mail, telephone or fax within the time limits set forth in service agreements. If your problem cannot be solved by support, you may need to return your equipment for servicing and will be given specific directions. We are not responsible for any damages incurred during shipment if the approved shipping container is not used. Shipping the units improperly can possibly void the warranty. If you purchased your business product from a business partner, please contact that business partner for support.

Chapter 1 Getting Started

Introduction The LS2208 scanner combines excellent scanning performance and advanced ergonomics to provide the best value in a lightweight laser scanner. Whether used as a hand-held scanner or in hands-free mode in a stand, the scanner ensures comfort and ease of use for extended periods of time. Figure 1-1 LS2208 Scanner

1 - 2

LS2208 Product Reference Guide The LS2208 scanner supports the following interfaces: • Standard RS-232 connection to a host. Scan bar code menus to set up proper communication of the scanner with the host. • Keyboard Wedge connection to a host. The host interprets scanned data as keystrokes. • International Keyboards supported: North America, German, French, French Canadian, French Belgian Windows, Spanish, Italian, Swedish, British, Japanese, and Portuguese-Brazilian. • Wand Emulation connection to a host. The scanner connects to a portable data terminal, a controller, or host which collects the data as wand data and decodes it. • Undecoded Emulation connection to a host. The scanner connects to a portable data terminal, and a controller which collects the data and interprets it for the host. • Connection to IBM 468X/469X hosts. Scan bar code menus to set up proper communication of the scanner with the IBM terminal. • USB connection to a host. The scanner autodetects a USB host and defaults to the HID keyboard interface type. Scan programming bar codes to select other USB interface types. • International Keyboards supported (for Windows environment): North America, German, French, French International, Spanish, Italian, Swedish, British, Portuguese-Brazilian, and Japanese. • Synapse capability. Enables connection to a wide variety of host systems using a Synapse and Synapse adapter cable. The scanner autodetects Synapse. • Configuration via 123Scan. Unpacking Your Scanner Remove the scanner from its packing and inspect it for damage. If the scanner was damaged in transit, contact support. See page xv for contact information. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.

1 - 3

Setting Up the Scanner Installing the Interface Cable 1. Plug the interface cable modular connector into the cable interface port on the bottom of the scanner handle. (See Figure 1-2.) 2. Gently tug the cable to ensure the connector is properly secured. 3. Connect the other end of the interface cable to the host (see the specific host chapter for information on host connections). Figure 1-2 Installing the Cable Interface Cable Modular Connector To host Cable Interface Port NOTE Different hosts require different cables. The connectors illustrated in each host chapter are examples only. Your connectors may be different than those illustrated, but the steps to connect the scanner are the same.

1 - 4

LS2208 Product Reference Guide Connecting Power (if required) If the host does not provide power to the scanner, use an external power connection to the scanner: 1. Connect the interface cable to the bottom of the scanner, as described in Installing the Interface Cable on page 1-3. 2. Connect the other end of the interface cable to the host (refer to the host manual to locate the correct port). 3. Plug the power supply into the power jack on the interface cable. Plug the other end of the power supply into an AC outlet. Configuring Your Scanner To configure the scanner, use the bar codes included in this manual, or the 123Scan configuration program. See Chapter 4, User Preferences for information about programming the scanner using bar code menus. See Chapter 11, 123Scan to configure the scanner using this configuration program. 123Scan includes a help file. The scanner supports RS-232, IBM 468X/469X, Keyboard Wedge, Wand Emulation, Undecoded Scanner Emulation, USB, and Synapse to interface to a host system. Each host specific chapter describes how to set up each of these connections.

1 - 5

Connecting a Synapse Cable Interface Symbol’s Synapse Smart Cables enable interfacing to a variety of hosts. The appropriate Synapse cable has the built-in intelligence to detect the host to which it is connected. Figure 1-3 Synapse Cable Connection 1. Plug the Synapse adapter cable (p/n 25-32463-xx) into the bottom of the scanner, as described in Installing the Interface Cable on page 1-3. 2. Align the ‘S’ on the Synapse adapter cable with the ‘S’ on the Synapse Smart Cable and plug the cable in. 3. Connect the other end of the Synapse Smart Cable to the host. Removing the Interface Cable To remove the interface cable: 1. Unplug the installed cable’s modular connector by depressing the connector clip with the tip of a screwdriver. 2. Carefully slide out the cable. 3. Follow the steps for Installing the Interface Cable on page 1-3 to connect a new cable. NOTE See the Synapse Interface Guide provided with the Synapse cable for detailed setup instructions. Synapse Adapter Cable To Scanner Synapse Smart Cable To Host

Chapter 2 Scanning

Introduction This chapter includes the techniques involved in scanning bar codes, beeper and LED definitions, and general instructions and tips about scanning. Figure 2-1 Scanner Parts LED Scan Window Trigger

2 - 2

LS2208 Product Reference Guide Beeper Definitions The scanner communicates by emitting different beeper sequences and patterns. Table 2-1 defines beep sequences that occur during both normal scanning and while programming the scanner. Table 2-1 Standard Beeper Definitions Beeper Sequence Indication Standard Use Low/medium/high beep Power up. Short high beep A bar code symbol was decoded (if decode beeper is enabled). 4 long low beeps A transmission error was detected in a scanned symbol. The data is ignored. This occurs if a unit is not properly configured. Check option setting. 5 low beeps Conversion or format error. Lo/hi/lo beep ADF transmit error. Hi/hi/hi/lo beep RS-232 receive error. Parameter Menu Scanning Short high beep Correct entry scanned or correct menu sequence performed. Lo/hi beep Input error, incorrect bar code or “Cancel” scanned, wrong entry, incorrect bar code programming sequence; remain in program mode. Hi/lo beep Keyboard parameter selected. Enter value using bar code keypad. Hi/lo/hi/lo beep Successful program exit with change in the parameter setting. Low/hi/low/hi beep Out of host parameter storage space. Scan Set Default Parameter on page 4-3. Code 39 Buffering Hi/lo beep New Code 39 data was entered into the buffer. 3 Beeps - long high beep Code 39 buffer is full. Lo/hi/lo beep The Code 39 buffer was erased or there was an attempt to clear or transmit an empty buffer. Lo/hi beep A successful transmission of buffered data.

2 - 3

LED Definitions In addition to beeper sequences, the scanner communicates using a two-color LED display. Table 2-2 defines LED colors that display during scanning. Host Specific USB only 4 short high beeps Scanner has not completed initialization. Wait several seconds and scan again. Scanner gives a power-up beep after scanning a USB Device Type. Communication with the bus must be established before the scanner can operate at the highest power level. This power-up beep occurs more than once. The USB bus may put the scanner in a state where power to the scanner is cycled on and off more than once. This is normal and usually happens when the PC cold boots. RS-232 only 1 short high beep A character is received and Beep on is enabled. Table 2-1 Standard Beeper Definitions (Continued) Beeper Sequence Indication Table 2-2 Standard LED Definitions LED Indication Off No power is applied to the scanner, or the scanner is on and ready to scan. Green A bar code was successfully decoded. Red A data transmission error or scanner malfunction occurred.

2 - 4

LS2208 Product Reference Guide Scanning in Hand-Held Mode Install and program the scanner. See each host chapter and Chapter 4, User Preferences, Chapter 12, Symbologies, Chapter 13, Miscellaneous Scanner Options, and Chapter 14, Advanced Data Formatting for programming instructions. For assistance, contact your local supplier or support. Figure 2-2 Scanning in Hand-Held Mode 1. Ensure all connections are secure. See the host chapter for your host. 2. Aim the scanner at the bar code. Press the trigger. 3. Ensure the scan line crosses every bar and space of the symbol. 4. Upon successful decode, the scanner beeps and the LED turns green. For more information on beeper and LED definitions, see Table 2-1 and Table 2-2. RIGHT 012345 WRONG 012345

2 - 5

Aiming Do not hold the scanner directly over the bar code. Laser light reflecting directly back into the scanner from the bar code is known as specular reflection. This specular reflection can make decoding difficult. You can tilt the scanner up to 55 forward or back and achieve a successful decode (Figure 2-3). Simple practice quickly shows what tolerances to work within. Figure 2-3 Maximum Tilt Angles and Dead Zone 65 65

2 - 6

LS2208 Product Reference Guide Decode Zone Figure 2-4 LS2208 Decode Zone in. cm 5 mil 6" 7.5 mil 10 mil 10.0" 14.5" 100% UPC 17.0" 23.0" 20 mil * in. cm W i d t h o f F i e l d *Minimum distance determined by symbol length and scan angle Depth of Field Note: Typical performance at 73˚ F (23˚ C) on high quality symbols in normal room light. 0 0 5 12.7 10 25.4 15 38.1 0 1.0" 1.5" 2.5" 20 50.8 25 63.5 LS 2208 10 25.4 5 12.7 0 0 5 12.7 10 25.4

2 - 7

Scanning in Hands-Free Mode The LS2208 Intellistand adds greater flexibility to scanning operation. See Assembling the Stand, Mounting the Stand (optional), and Scanning in the Hands-Free Mode for more information about hands-free scanning. Assembling the Stand Figure 2-5 Assembling the Stand Stand base Wingnut 1. Unscrew the wing nut from the bottom of the one piece scanner “cup”. 2. Fit the bottom of the neck piece into the opening on the top of the stand base. 3. Tighten the wing nut underneath the base to secure the cup and neck piece to the base (see the note below). 4. Bend the neck to the desired position for scanning. One piece scanner “cup” with flexible neck. Flat areas NOTE Before tightening the wing nut under the base, ensure that the flat areas on the flexible neck fit securely in the grooves in the base.

2 - 8

LS2208 Product Reference Guide Mounting the Stand (optional) You can attach the base of the scanner’s stand to a flat surface using two screws or double-sided tape (not provided). Figure 2-6 Mounting the Stand Screw Mount 1. Position the assembled base on a flat surface. 2. Screw one #10 wood screw into each screw-mount hole until the base of the stand is secure (see Figure 2-6). Tape Mount 1. Peel the paper liner off one side of each piece of tape and place the sticky surface over each of the three rectangular tape holders. 2. Peel the paper liner off the exposed sides of each piece of tape and press the stand on a flat surface until it is secure (see Figure 2-6). Two screw-mount holes Double-sided tape areas (3 places) dimensions = 1” x 2”)

2 - 9

Scanning in Hands-Free Mode The optional Intellistand adds greater flexibility to scanning operation. Scanning in the Hands-Free Mode When the scanner is seated in the stand’s “cup”, the scanner’s built-in sensor places the scanner in hands-free mode. When you remove the scanner from the stand it operates in its normal hand-held mode. Figure 2-7 Inserting and Using the Scanner in the Stand Intellistand operation: 1. Ensure all cable connections are secure. 2. Insert the scanner in the optional Intellistand by placing the front of the scanner into the stand’s “cup” (see Figure 2-7). 3. To scan a bar code, present the bar code and ensure the scan line crosses every bar and space of the symbol. 4. Upon successful decode, the scanner beeps and the LED turns green. Scanner Holder (Front)

Chapter 3 Maintenance and Technical

Specifications Introduction This chapter includes suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts). Maintenance Cleaning the exit window is the only maintenance required. A dirty window can affect scanning accuracy. • Do not allow any abrasive material to touch the window • Remove any dirt particles with a damp cloth • Wipe the window using a tissue moistened with ammonia/water • Do not spray water or other cleaning liquids directly into the window.

3 - 2

LS2208 Product Reference Guide Troubleshooting Table 3-1 Troubleshooting Problem Possible Causes Possible Solutions Nothing happens when you follow the operating instructions, or the scanner displays erratic behavior (laser does not come on, scanner emits frequent beeps). No power to the scanner. Check the system power. Ensure the power supply is connected if your configuration requires a power supply. Interface/power cables are loose. Check for loose cable connections. Laser comes on, but symbol does not decode. Scanner is not programmed for the correct bar code type. Be sure the scanner is programmed to read the type of bar code you are scanning. Bar code symbol is unreadable. Check the symbol to make sure it is not defaced. Try scanning test symbols of the same bar code type. Distance between scanner and bar code is incorrect. Move the scanner closer to or further from the bar code. Symbol is decoded, but not transmitted to the host. Scanner is not programmed for the correct host type. Scan the appropriate host type bar code.

Maintenance and Technical Specifications

3 - 3 Scanned data is incorrectly displayed on the host. Scanner is not programmed to work with the host. Check scanner host type parameters or editing options. Be sure proper host is selected. (See the host chapter for your scanner.) For RS-232, ensure the scanner’s communication parameters match the host’s settings. For a USB HID keyboard or a keyboard wedge configuration, ensure the system is programmed for the correct keyboard type and language, and the CAPS LOCK key is in the correct state. Be sure editing options (e.g., ADF, UPC-E to UPC-A Conversion) are properly programmed. Table 3-1 Troubleshooting (continued) Problem Possible Causes Possible Solutions NOTE If after performing these checks the symbol still does not scan, contact your distributor or support. See page xv for contact information.

3 - 4

LS2208 Product Reference Guide Technical Specifications Table 3-2 Technical Specifications Item Description Power Requirements Use only a Zebra-approved power supply (p/n 50-14000-253R, 50-14000-256R, 50-14000-257R, 50-14000-258R or 50-14000-259R) output rated 5 VDVC and minimum 650mA. The power supply is certified to EN60950 with SELV outputs. Use of alternative power supply will invalidate any approval given to this device and may be dangerous. Stand-By Current 500mA (max) Power Source Depending on host: • Host powered • External power supply • Battery box: Converts a 9 Volt battery to a 5 Volt battery Decode Capability Decoded: UPC/EAN, UPC/EAN with supplementals, UCC/EAN, JAN 8 & 13, 128, Code 39, Code 39 Full ASCII, Code 39 Trioptic, Codabar (NW7), Interleaved 2 of 5, Discrete 2 of 5, Code 128, Code 93, MSI, Code 11, UCC/EAN, GS1 DataBar, Code 32, Coupon Code, Bookland EAN, IATA. Beeper Operation User-selectable: Enable, Disable Beeper Volume User-selectable: three levels Beeper Tone User-selectable: three tones Scan Repetition Rate 100 ± 5 scans/second Yaw Tolerance ± 10° from nominal Pitch Tolerance ± 65° from nominal Roll Tolerance ± 60° from nominal Print Contrast Minimum 25% minimum reflectance differential, measured at 650 nm. Ambient Light Tolerance Tolerant to typical artificial indoor and natural outdoor (direct sunlight) lighting conditions. Fluorescent, Incandescent, Mercury Vapor, Sodium Vapor, LED: 450 Ft Candles (4,844 Lux) Sunlight: 8000 Ft Candles (86,111 Lux) Note: LED lighting with high AC ripple content can impact scanning performance. Durability 5 ft (1.5 m) drops to concrete Operating Temperature 32° to 120° F (0° to 50° C) Storage Temperature -40° to 140° F (-40° to 60° C) Humidity 5% to 95% (non-condensing) Weight (without cable) 5.15 oz. (146 g)

Maintenance and Technical Specifications

3 - 5 Dimensions: Height Width Depth 6.0 in. (15.2 cm) 2.5in. (6.3 cm) 3.34 in. (8.4 cm) Laser 650nm laser diode ESD 15 kV area discharge 8 kV contact discharge Minimum Element Width 5 mil (0.127 mm) Interfaces Supported Decoded: RS-232, Keyboard Wedge, Wand Emulation, Undecoded Scanner Emulation, IBM 468X/469X, USB, Synapse Table 3-2 Technical Specifications (continued) Item Description

3 - 6

LS2208 Product Reference Guide Scanner Signal Descriptions Figure 3-1 Scanner Cable Pinouts PIN 10 Bottom of Scanner PIN 1 Interface Cable Modular Connector Cable Interface Port

Maintenance and Technical Specifications

3 - 7 The signal descriptions in Table 3-3 apply to the connector on the scanner and are for reference only. Table 3-3 Scanner Signal Pin-outs LS2208 Pin IBM Synapse RS-232 Keyboard Wedge Wand USB Scanner Emulation 1 Reserved SynClock Reserved Reserved Reserved Jump to Pin 6 DBP 2 Power Power Power Power Power Power Power 3 Ground Ground Ground Ground Ground Ground Ground 4 IBM_A(+) Reserved TxD KeyClock DBP Reserved SOS 5 Reserved Reserved RxD TermData CTS D + Decode 6 IBM_B(-) SynData RTS KeyData RTS Jump to Pin 1 Trigger 7 Reserved Reserved CTS TermClock Reserved D - Enable 8 Reserved Reserved Reserved Reserved Reserved Reserved Reserved 9 Reserved Reserved Reserved Reserved Reserved Reserved Reserved 10 Reserved Reserved Reserved Reserved Reserved Reserved Reserved NOTE Wand is only supported with the LS2208-SR20541R and LS2208-SR20547R configurations.

Chapter 4 User Preferences

Introduction You can program the LS2208 scanner to perform various functions, or activate different features. This chapter describes each user preference feature and provides programming bar codes for selecting these features for the LS2208 scanner. The LS2208 ships with the settings shown in the User Preferences Default Table on page 4-2 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous scanner defaults). If the default values suit requirements, programming is not necessary. Set feature values by scanning single bar codes or short bar code sequences. The settings are stored in non-volatile memory and are preserved even when the scanner is powered down. If you are not using a Keyboard Wedge or USB cable you must select a host type (see each host chapter for specific host information). After the power-up beeps sound, select a host type. You only need to this once, upon the first power-up when connecting to a new host. To return all features to their default values, scan Set All Defaults on page 4-3. Throughout the programming bar code menus, asterisks (*) indicate default values. Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high, scan the High Frequency (beeper tone) bar code under Beeper Tone on page 4-4. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as specifying Serial Response Time-Out or setting Data Transmission Formats, require scanning several bar codes. See Laser On Time on page 4-7 and Scan Data Transmission Format on page 13-4 for descriptions of this procedure. *High Frequency Feature/Option * Indicates Default

4 - 2

LS2208 Product Reference Guide Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter. User Preferences Default Parameters Table 4-1 lists the defaults for user preferences parameters. To change any option, scan the appropriate bar code(s) provided in the User Preferences section beginning on page 4-3. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters. Table 4-1 User Preferences Default Table Parameter Default Page Number User Preferences Set Default Parameter All Defaults 4-3 Beeper Tone Medium 4-4 Beeper Volume High 4-5 Power Mode Continuous On 4-6 Laser On Time 3.0 Sec 4-7 Beep After Good Decode Enable 4-8 Timeout Between Decodes Time-out Between Same Symbol 0.6 sec 4-9 Time-out Between Different Symbols 0.2 sec 4-9

4 - 3

User Preferences Set Default Parameter Scanning this bar code returns all parameters to the default values listed in Table A-1 on page A-1. Set All Defaults

4 - 4

LS2208 Product Reference Guide Beeper Tone To select a decode beep frequency (tone), scan the Low Frequency, Medium Frequency, or High Frequency bar code. Low Frequency *Medium Frequency (Optimum Settings) High Frequency

4 - 5

Beeper Volume To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code. Low Volume Medium Volume *High Volume

4 - 6

LS2208 Product Reference Guide Power Mode This parameter determines whether or not power remains on after a decode attempt. When in reduced power mode, the scanner enters into a low power consumption mode to preserve battery life after each decode attempt. When in continuous power mode, power remains on after each decode attempt. *Continuous On Reduced Power Mode

4 - 7

Laser On Time This parameter sets the maximum time that decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default Laser On Time is 3.0 seconds. To set a Laser On Time, scan the bar code below. Next, scan two numeric bar codes beginning on page D-1 in Appendix D, Numeric Bar Codes that correspond to the desired on time. Include a leading zero for single digit numbers. For example, to set an On Time of 0.5 seconds, scan the bar code below, then scan the “0” and “5” bar codes. To correct an error or change a selection, scan Cancel on page D-3. Laser On Time

4 - 8

LS2208 Product Reference Guide Beep After Good Decode Scan a bar code below to select whether or not the scanner beeps after a good decode. If you select Do Not Beep After Good Decode, the beeper still operates during parameter menu scanning and indicates error conditions. *Beep After Good Decode (Enable) Do Not Beep After Good Decode (Disable)

4 - 9

Timeout Between Decodes Timeout Between Decodes, Same Symbol This parameter sets the minimum time between decodes of the same symbol. It is programmable in 0.1-second increments from 0.0 to 9.9 seconds. Setting this above 0.4 seconds is recommended. The default for this parameter is 0.6 seconds. Scan the bar code below to select a new timeout. Next, scan two numeric bar codes beginning in Numeric Bar Codes on page D-1 that correspond to the desired timeout. Include a leading zero for single digit numbers. For example, to set a timeout of 0.5 seconds, scan the bar code below, then scan the “0” and “5” bar codes. If an error occurs, or to change the selection, scan Cancel on page D-3. Timeout Between Same Symbol Timeout Between Decodes, Different Symbol This parameter sets the minimum time between decodes of different symbols. It is programmable in 0.1-second increments from 0.0 to 9.9 seconds. The default for this parameter is 0.2 seconds. Scan the bar code below to select a new timeout. Next, scan two numeric bar codes beginning in Numeric Bar Codes on page D-1 that correspond to the desired timeout. Include a leading zero for single digit numbers. For example, to set a timeout of 0.5 seconds, scan the bar code below, then scan the “0” and “5” bar codes. If an error occurs, or to change the selection, scan Cancel on page D-3. Timeout Between Different Symbol

Chapter 5 Keyboard Wedge Interface

Introduction This chapter covers Keyboard Wedge interface information for setting up the scanner. Use this interface type to attach the scanner between the keyboard and host computer. The scanner translates the bar code data into keystrokes. The host computer accepts the keystrokes as if they originate from the keyboard. This mode of operation allows adding bar code reading functionality to a system designed for manual keyboard input. In this mode the keyboard keystrokes are simply passed through. Throughout the programming bar code menus, asterisks (*) indicate default values. *North American Feature/Option * Indicates Default

5 - 2

LS2208 Product Reference Guide Connecting a Keyboard Wedge Interface Figure 5-1 Keyboard Wedge Connection with Y-cable To connect the Keyboard Wedge Y-cable: 1. Switch off the host and unplug the keyboard connector. 2. Attach the modular connector of the Y-cable to the cable interface port on the scanner. (See Installing the Interface Cable on page 1-3.) 3. Connect the round male DIN host connector of the Y-cable to the keyboard port on the host device. 4. Connect the round female DIN keyboard connector of the Y-cable to the keyboard. 5. If needed, attach the optional power supply to the connector in the middle of the Y-cable. 6. Ensure that all connections are secure. 7. Switch on the host system. 8. Scan the appropriate bar codes in this chapter to configure the scanner. Power supply (if needed) Y-cable Male DIN Keyboard Connector to Host Connector to Host

Keyboard Wedge Interface

5 - 3 Keyboard Wedge Default Parameters Table 5-1 lists the defaults for Keyboard Wedge host parameters. To change any option, scan the appropriate bar code(s) provided in the Keyboard Wedge Host Parameters section beginning on page 5-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters. Table 5-1 Keyboard Wedge Host Default Table Parameter Default Page Number Keyboard Wedge Host Parameters Keyboard Wedge Host Type IBM PC/AT& IBM PC Compatibles1 5-4 Country Types (Country Codes) North American 5-5 Ignore Unknown Characters Transmit 5-7 Keystroke Delay No Delay 5-8 Intra-Keystroke Delay Disable 5-9 Alternate Numeric Keypad Emulation Disable 5-9 Caps Lock On Disable 5-10 Caps Lock Override Disable 5-10 Convert Wedge Data No Convert 5-11 Function Key Mapping Disable 5-12 FN1 Substitution Disable 5-13 Send and Make Break Send 5-13 1User selection is required to configure this interface and this is the most common selection.

5 - 4

LS2208 Product Reference Guide Keyboard Wedge Host Types Keyboard Wedge Host Types Select the keyboard wedge host by scanning one of the bar codes below. IBM PC/AT & IBM PC Compatibles1 IBM PS/2 (Model 30) IBM AT NOTEBOOK NCR 7052 NOTE User selection is required to configure this interface and this is the most common selection.

Keyboard Wedge Interface

5 - 5 Keyboard Wedge Country Types (Country Codes) Scan the bar code corresponding to the keyboard type. If your particular keyboard type is not listed, see Alternate Numeric Keypad Emulation on page 5-9. *North American German Windows French Windows French Canadian Windows 95/98 French Canadian Windows XP/2000 French Belgian Windows

5 - 6

LS2208 Product Reference Guide Keyboard Wedge Country Types (Country Codes) (continued) Spanish Windows Italian Windows Swedish Windows UK English Windows Japanese Windows Portuguese-Brazilian Windows

Keyboard Wedge Interface

5 - 7 Ignore Unknown Characters Unknown characters are characters the host does not recognize. Select Send Bar Codes With Unknown Characters to send all bar code data except for unknown characters. The scanner sounds no error beeps. Select Do Not Send Bar Codes With Unknown Characters to send bar code data up to the first unknown character. The scanner sounds an error beep. *Send Bar Codes with Unknown Characters (Transmit) Do Not Send Bar Codes with Unknown Characters

5 - 8

LS2208 Product Reference Guide Keystroke Delay This is the delay in milliseconds between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data. *No Delay Medium Delay (20 msec) Long Delay (40 msec)

Keyboard Wedge Interface

5 - 9 Intra-Keystroke Delay Enable this to insert an additional delay between each emulated key depression and release. This sets the Keystroke Delay parameter to a minimum of 5 msec as well. Enable *Disable Alternate Numeric Keypad Emulation This allows emulation of most other country keyboard types not listed in Keyboard Wedge Country Types (Country Codes) on page 5-5 in a Microsoft operating system environment. Enable Alternate Numeric Keypad *Disable Alternate Numeric Keypad

5 - 10

LS2208 Product Reference Guide Caps Lock On When enabled, the scanner emulates keystrokes as if the Caps Lock key is always pressed. Enable Caps Lock On *Disable Caps Lock On Caps Lock Override When enabled, on AT or AT Notebook hosts, the keyboard ignores the state of the Caps Lock key. Therefore, an ‘A’ in the bar code transmits as an ‘A’ regardless of the state of the keyboard’s Caps Lock key. Enable Caps Lock Override *Disable Caps Lock Override NOTE If both Caps Lock On and Caps Lock Override are enabled, Caps Lock Override takes precedence.

Keyboard Wedge Interface

5 - 11 Convert Wedge Data Enable this to convert all bar code data to the selected case. Convert to Upper Case Convert to Lower Case *No Convert

5 - 12

LS2208 Product Reference Guide Function Key Mapping ASCII values under 32 are normally sent as control key sequences (see Table 5-2 on page 5-16). Enable this to send the keys in bold in place of the standard key mapping. Table entries that do not have a bold entry remain the same whether or not you enabled this parameter. Enable *Disable

Keyboard Wedge Interface

5 - 13 FN1 Substitution Enable this to allow replacing any FN1 characters in an EAN128 bar code with a user-selected keystroke (see FN1 Substitution Values on page 13-6). Enable *Disable Send Make and Break When enabled, the scan codes for releasing a key are not sent. *Send Make and Break Scan Codes Send Make Scan Code Only

5 - 14

LS2208 Product Reference Guide Keyboard Maps Use the following keyboard maps for reference for prefix/suffix keystroke parameters. To program the prefix/suffix values, see the bar codes on page 13-4. Figure 5-2 IBM PS2 Type Keyboard Figure 5-3 IBM PC/AT Figure 5-4 NCR 7052 32-KEY IBM PS/2 7014 5001 7009 5002 5003 5004 5005 5006 5007 5008 5009 5010 5011 5012 7008 7013 7011 7002 7012 7004 7003 7005 7010 7007 7006 7001 7017 7018 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 7009 7008 7013 7012 7004 7011 7003 7002 7014 5007 5008 5010 5002 5003 5004 5005 5006 1046 1045 5014 1043 5013 5015 5016 5018 5019 5001 5017 7013 5011 (7013 if double key) (1048 if double key) 1048 5012 5009

Keyboard Wedge Interface

5 - 15 Keyboard Maps (continued) Figure 5-5 NCR 7052 58-KEY 5007 5008 5010 5002 5003 5004 5005 5006 1046 1045 5014 1043 5013 5015 5016 5018 5019 1086 1087 1088 1089 1090 5001 1066 1072 1073 1079 1080 1065 1070 1076 1077 1083 1084 1071 1078 1085 1069 5017 7013 5011 1082 1075 1068 1067 (1043 if double key) (1048 if double key) 1048 5012 5009 1074 1081

5 - 16

LS2208 Product Reference Guide ASCII Character Set NOTE Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when if you enable Code 39 Full ASCII and scan a +B, it is interpreted as b, %J as ?, and %V as @. Scanning ABC%I outputs the keystroke equivalent of ABC >. Table 5-2 Keyboard Wedge ASCII Character Set ASCII Value Full ASCII Code 39 Encode Char. Keystroke 1001 $A CTRL A 1002 $B CTRL B 1003 $C CTRL C 1004 $D CTRL D 1005 $E CTRL E 1006 $F CTRL F 1007 $G CTRL G 1008 $H CTRL H/BACKSPACE1 1009 $I CTRL I/HORIZONTAL TAB1 1010 $J CTRL J 1011 $K CTRL K 1012 $L CTRL L 1013 $M CTRL M/ENTER1 1014 $N CTRL N 1015 $O CTRL O 1016 $P CTRL P 1017 $Q CTRL Q 1018 $R CTRL R 1019 $S CTRL S 1020 $T CTRL T 1021 $U CTRL U The keystroke in bold transmits only if you enabled Function Key Mapping on page 5-12. Otherwise, the unbolded keystroke transmits.

Keyboard Wedge Interface

5 - 17 1022 $V CTRL V 1023 $W CTRL W 1024 $X CTRL X 1025 $Y CTRL Y 1026 $Z CTRL Z 1027 %A CTRL [ /ESC1 1028 %B CTRL \ 1029 %C CTRL ] 1030 %D CTRL 6 1031 %E CTRL - 1032 Space Space 1033 /A ! 1034 /B “ 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . . 1047 /O / 1048 0 0 Table 5-2 Keyboard Wedge ASCII Character Set (continued) ASCII Value Full ASCII Code 39 Encode Char. Keystroke The keystroke in bold transmits only if you enabled Function Key Mapping on page 5-12. Otherwise, the unbolded keystroke transmits.

5 - 18

LS2208 Product Reference Guide 1049 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 /Z : 1059 %F ; 1060 %G < 1061 %H = 1062 %I > 1063 %J ? 1064 %V @ 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K Table 5-2 Keyboard Wedge ASCII Character Set (continued) ASCII Value Full ASCII Code 39 Encode Char. Keystroke The keystroke in bold transmits only if you enabled Function Key Mapping on page 5-12. Otherwise, the unbolded keystroke transmits.

Keyboard Wedge Interface

5 - 19 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 %K [ 1092 %L \ 1093 %M ] 1094 %N ^ 1095 %O _ 1096 %W ‘ 1097 +A a 1098 +B b 1099 +C c 1100 +D d 1101 +E e 1102 +F f Table 5-2 Keyboard Wedge ASCII Character Set (continued) ASCII Value Full ASCII Code 39 Encode Char. Keystroke The keystroke in bold transmits only if you enabled Function Key Mapping on page 5-12. Otherwise, the unbolded keystroke transmits.

5 - 20

LS2208 Product Reference Guide 1103 +G g 1104 +H h 1105 +I i 1106 +J j 1107 +K k 1108 +L l 1109 +M m 1110 +N n 1111 +O o 1112 +P p 1113 +Q q 1114 +R r 1115 +S s 1116 +T t 1117 +U u 1118 +V v 1119 +W w 1120 +X x 1121 +Y y 1122 +Z z 1123 %P { 1124 %Q | 1125 %R } 1126 %S ~ Table 5-2 Keyboard Wedge ASCII Character Set (continued) ASCII Value Full ASCII Code 39 Encode Char. Keystroke The keystroke in bold transmits only if you enabled Function Key Mapping on page 5-12. Otherwise, the unbolded keystroke transmits.

Keyboard Wedge Interface

5 - 21 Table 5-3 Keyboard Wedge ALT Keys ALT Keys Keystroke 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z

5 - 22

LS2208 Product Reference Guide Table 5-4 Keyboard Wedge GUI Keys GUI Keys Keystroke 3000 Right Control Key 3048 GUI 0 3049 GUI 1 3050 GUI 2 3051 GUI 3 3052 GUI 4 3053 GUI 5 3054 GUI 6 3055 GUI 7 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P 3081 GUI Q

Keyboard Wedge Interface

5 - 23 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Table 5-5 Keyboard Wedge F Keys F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 Table 5-4 Keyboard Wedge GUI Keys (continued) GUI Keys Keystroke

5 - 24

LS2208 Product Reference Guide 5018 F18 5019 F19 5020 F20 5021 F21 5022 F22 5023 F23 5024 F24 Table 5-6 Keyboard Wedge Numeric Keypad Numeric Keypad Keystroke 6042 * 6043 + 6044 undefined 6045 - 6046 . 6047 / 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock Table 5-5 Keyboard Wedge F Keys (continued) F Keys Keystroke

Keyboard Wedge Interface

5 - 25 Table 5-7 Keyboard Wedge Extended Keypad Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Dn Arrow 7017 Left Arrow 7018 Right Arrow

Chapter 6 RS-232 Interface

Introduction This chapter includes RS-232 host information for setting up the scanner. Use the RS-232 interface to attach the scanner to point-of-sale devices, host computers, or other devices with an available RS-232 port (e.g., com port). If your particular host is not listed in Table 6-2, set the communication parameters to match the host device. Refer to the documentation for the host device. Throughout the programming bar code menus, asterisks (*) indicate default values. NOTE This scanner uses TTL RS-232 signal levels, which interface with most system architectures. For system architectures requiring RS-232C signal levels, Zebra offers different cables providing TTL to RS-232C conversion. Contact support for more information. *Baud Rate 9600 Feature/Option * Indicates Default

6 - 2

LS2208 Product Reference Guide Connecting an RS-232 Interface The scanner connects directly to the host computer. Figure 6-1 RS-232 Direct Connection 1. Connect the RS-232 interface cable to the bottom of the scanner, as described in Installing the Interface Cable on page 1-3. 2. Connect the other end of the interface cable to the serial port on the host. 3. Connect the power supply. 4. Scan appropriate bar codes in this chapter to match host settings. Serial Port Connector to Host Interface Cable Power Supply Interface Cable Power Supply Cable

6 - 3

RS-232 Default Parameters Table 6-1 lists the defaults for RS-232 host parameters. To change any option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 6-4. NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters. Table 6-1 RS-232 Host Default Table Parameter Default Page Number RS-232 Host Parameters RS-232 Host Types Standard1 6-6 Baud Rate 9600 6-8 Parity Type None 6-10 Stop Bit Select 1 Stop Bit 6-12 Data Bits 8-Bit 6-12 Check Receive Errors Enable 6-13 Hardware Handshaking None 6-14 Software Handshaking None 6-16 Host Serial Response Time-out 2 Sec 6-18 RTS Line State Low RTS 6-19 Beep on Disable 6-19 Intercharacter Delay 0 msec 6-20 Nixdorf Beep/LED Options Normal Operation 6-21 Ignore Unknown Characters Send Bar Code 6-21 1User selection is required to configure this interface and this is the most common selection.

6 - 4

LS2208 Product Reference Guide RS-232 Host Parameters The RS-232 hosts listed in Table 6-2 use their own parameter default settings. Selecting the ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, Olivetti, Omron, or terminal sets the defaults listed. Table 6-2 Terminal Specific RS-232 Parameter Standard (Default) ICL Fujitsu Wincor- Nixdorf Mode A Wincor- Nixdorf Mode B/ OPOS Olivetti Omron Transmit Code ID No Yes Yes Yes Yes Yes Yes Data Transmission Format Data as is Data/ Suffix Data/ Suffix Data/Suffix Data/Suffix Prefix/Data/ Suffix Data/ Suffix Suffix CR/LF (7013) CR (1013) CR (1013) CR (1013) CR (1013) ETX (1002) CR (1013) Baud Rate 9600 9600 9600 9600 9600 9600 9600 Parity None Even None Odd Odd Even None Hardware Handshaking None RTS/CTS Option 3 None RTS/CTS Option 3 RTS/CTS Option 3 None None Software Handshaking None None None None None Ack/Nak None Serial Response Time-out 2 Sec. 9.9 Sec. 2 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec. Stop Bit Select One One One One One One One ASCII Format 8-Bit 8-Bit 8-Bit 8-Bit 8-Bit 7-Bit 8-Bit Beep On Disable Disable Disable Disable Disable Disable Disable RTS Line State Low High Low Low Low = No data to send Low High Prefix None None None None None STX (1003) None *In the Nixdorf Mode B, if CTS is low, scanning is disabled. When CTS is high, scanning is enabled. **If you scan Nixdorf Mode B without connecting the scanner to the proper host, it may appear unable to scan. If this occurs, scan a different RS-232 host type within 5 seconds of cycling power to the scanner.

6 - 5

RS-232 Host Parameters (continued) Selecting the ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS terminal enables the transmission of code ID characters listed in Table 6-3 below. These code ID characters are not programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature for these terminals. Table 6-3 Terminal Specific Code ID Characters Code Type ICL Fujitsu Wincor- Nixdorf Mode A Wincor- Nixdorf Mode B/ OPOS Olivetti Omron UPC-A A A A A A A UPC-E E E C C C E EAN-8/JAN-8 FF FF B B B FF EAN-13/JAN-13 F F A A A F Code 39 C None M M M C Codabar N None N N N N Code 128 L None K K K L I 2 of 5 I None I I I I Code 93 None None L L L None D 2 of 5 H None H H H H UCC/EAN 128 L None P P P L MSI None None O O O None Bookland EAN F F A A A F Trioptic None None None None None None Code 11 None None None None None None IATA H None H H None None Code 32 None None None None None None

6 - 6

LS2208 Product Reference Guide RS-232 Host Types To select an RS-232 host interface, scan one of the following bar codes. Standard RS-2321 ICL RS-232 Wincor-Nixdorf RS-232 Mode A Wincor-Nixdorf RS-232 Mode B Olivetti ORS4500

6 - 7

RS-232 Host Types (continued) Omron OPOS/JPOS Fujitsu RS-232 NOTE 1User selection is required to configure this interface and this is the most common selection.

6 - 8

LS2208 Product Reference Guide Baud Rate Baud rate is the number of bits of data transmitted per second. Set the scanner's baud rate to match the host’s baud rate setting, or data may not reach the host device or may reach it in distorted form. Baud Rate 600 Baud Rate 1200 Baud Rate 2400 Baud Rate 4800

6 - 10

LS2208 Product Reference Guide Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. Select Odd parity to set the parity bit value to 0 or 1, based on data, to ensure that the coded character contains an odd number of 1 bits. Odd Select Even parity to set the parity bit value to 0 or 1, based on data, to ensure that the coded character contains an even number of 1 bits. Even Select Mark parity and the parity bit is always 1. Mark

6 - 11

Parity (continued) Select Space parity and the parity bit is always 0. Space Select None when no parity bit is required. *None

6 - 12

LS2208 Product Reference Guide Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. Select the number of stop bits (one or two) depending on the number the receiving terminal/host is programmed to accommodate. *1 Stop Bit 2 Stop Bits Data Bits This parameter allows the scanner to interface with devices requiring a 7-bit or 8-bit ASCII protocol. 7-Bit *8-Bit

6 - 13

Check Receive Errors Select whether or not to check the parity, framing, and overrun of received characters. The parity value of received characters is verified against the parity parameter selected above. *Check For Received Errors Do Not Check For Received Errors

6 - 14

LS2208 Product Reference Guide Hardware Handshaking The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and Clear to Send (CTS). Disable Standard RTS/CTS handshaking to transmit scan data as it becomes available. Select Standard RTS/CTS handshaking to transmit scan data according to the following sequence: • The scanner reads the CTS line for activity. If CTS is asserted, the scanner waits up to Host Serial Response Time-out for the host to negate the CTS line. If, after the Host Serial Response Time-out (default), the CTS line is still asserted, the scanner sounds a transmit error, and discards any scanned data. • When the CTS line is negated, the scanner asserts the RTS line and waits up to Host Serial Response Time-out for the host to assert CTS. When the host asserts CTS, the scanner transmits data. If, after the Host Serial Response Time-out (default), the CTS line is not asserted, the scanner sounds a transmit error, and discards the data. • When data transmission completes, the scanner negates RTS 10 msec after sending the last character. • The host should respond by negating CTS. The scanner checks for a negated CTS upon the next data transmission. During data transmission, the CTS line should be asserted. If CTS is deasserted for more than 50 ms between characters, the transmission aborts, and the scanner sounds a transmission error and discards the data. If this communications sequence fails, the scanner issues an error indication and discards the data. You must rescan the data. If hardware handshaking and software handshaking are both enabled, hardware handshaking takes precedence. None Scan the bar code below to disable hardware handshaking. *None Standard RTS/CTS Scan the bar code below to select Standard RTS/CTS hardware handshaking. Standard RTS/CTS NOTE The DTR signal is jumpered to the active state.

6 - 15

RTS/CTS Option 1 If you select RTS/CTS Option 1, the scanner asserts RTS before transmitting and ignores the state of CTS. The scanner de-asserts RTS when the transmission completes. RTS/CTS Option 1 RTS/CTS Option 2 If you select Option 2, RTS is always high or low (user-programmed logic level). However, the scanner waits for CTS to be asserted before transmitting data. If CTS is not asserted within Host Serial Response Time-out (default), the scanner issues an error indication and discards the data. RTS/CTS Option 2 RTS/CTS Option 3 If you select Option 3, the scanner asserts RTS prior to any data transmission, regardless of the state of CTS. The scanner waits up to Host Serial Response Time-out (default) for CTS to be asserted. If CTS is not asserted during this time, the scanner issues an error indication and discards the data. The scanner de-asserts RTS when transmission is complete. RTS/CTS Option 3

6 - 16

LS2208 Product Reference Guide Software Handshaking This parameter offers control of the data transmission process in addition to, or instead of, the control that hardware handshaking offers. There are five options. If software handshaking and hardware handshaking are both enabled, hardware handshaking takes precedence. None Select this option to transmit data immediately. No response is expected from host. *None ACK/NAK If you select this option, after transmitting data, the scanner expects either an ACK or NAK response from the host. When a NAK is received, the scanner transmits the same data again and waits for either an ACK or NAK. After three unsuccessful attempts to send data after receiving NAKs, the scanner issues an error indication and discards the data. The scanner waits up to the programmable Host Serial Response Time-out to receive an ACK or NAK. If the scanner does not get a response in this time, it issues an error indication and discards the data. There are no retries when a time-out occurs. ACK/NAK ENQ If you select this option, the scanner waits for an ENQ character from the host before transmitting data. If the scanner does not receive an ENQ within the Host Serial Response Time-out, it issues an error indication and discards the data. The host must transmit an ENQ character at least every Host Serial Response Time-out to prevent transmission errors. ENQ

6 - 17

ACK/NAK with ENQ This combines the two previous options. For re-transmissions of data due to a NAK from the host, an additional ENQ is not required. ACK/NAK with ENQ XON/XOFF An XOFF character turns the scanner transmission off until the scanner receives an XON character. There are two situations for XON/XOFF: • The scanner receives an XOFF before it has data to send. When the scanner has data to send, it waits up to Host Serial Response Time-out for an XON character before transmission. If it does not receive an XON within this time, it issues an error indication and discards the data. • The scanner receives an XOFF during a transmission. Data transmission then stops after sending the current byte. When the scanner receives an XON character, it sends the rest of the data message. The scanner waits up to 30 seconds for the XON. XON/XOFF

6 - 18

LS2208 Product Reference Guide Host Serial Response Time-out This parameter specifies how long the scanner waits for an ACK, NAK, or CTS before determining that a transmission error occurred. This only applies when in one of the ACK/NAK software handshaking modes, or in RTS/CTS hardware handshaking mode. *Minimum: 2 Sec Low: 2.5 Sec Medium: 5 Sec High: 7.5 Sec Maximum: 9.9 Sec

6 - 19

RTS Line State This parameter sets the idle state of the Serial Host RTS line. Scan a bar code below to select Low RTS or High RTS line state. *Host: Low RTS Host: High RTS Beep on If you enable this parameter, the scanner issues a beep when it detects a character on the RS-232 serial line. gains a user's attention to an illegal entry or other important event. Beep On Character (Enable) *Do Not Beep On Character (Disable)

6 - 20

LS2208 Product Reference Guide Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions. *Minimum: 0 msec Low: 25 msec Medium: 50 msec High: 75 msec Maximum: 99 msec

6 - 21

Nixdorf Beep/LED Options When Nixdorf Mode B is selected, this indicates when the scanner beeps and turns on its LED after a decode. *Normal Operation (Beep/LED immediately after decode) Beep/LED After Transmission Beep/LED After CTS Pulse Ignore Unknown Characters Unknown characters are characters the host does not recognize. Select Send Bar Codes with Unknown Characters to send all bar code data except for unknown characters. The scanner sounds no error beeps. Select Do Not Send Bar Codes With Unknown Characters to send bar code data up to the first unknown character. The scanner sounds an error beep. *Send Bar Code (with unknown characters) Do Not Send Bar Codes (with unknown characters)

6 - 22

LS2208 Product Reference Guide ASCII Character Set You can assign the values in Table 6-4 as prefixes or suffixes for ASCII character data transmission. Table 6-4 Prefix/Suffix Values Prefix/Suffix Value Full ASCII Code 39 Encode Character ASCII Character 1000 %U NUL 1001 $A SOH 1002 $B STX 1003 $C ETX 1004 $D EOT 1005 $E ENQ 1006 $F ACK 1007 $G BELL 1008 $H BCKSPC 1009 $I HORIZ TAB 1010 $J LF/NW LN 1011 $K VT 1012 $L FF 1013 $M CR/ENTER 1014 $N SO 1015 $O SI 1016 $P DLE 1017 $Q DC1/XON 1018 $R DC2 1019 $S DC3/XOFF 1020 $T DC4 1021 $U NAK 1022 $V SYN 1023 $W ETB 1024 $X CAN 1025 $Y EM 1026 $Z SUB