ABB 265Ax Safety Instructions

Brand: ABB
Category: Transmitter
Model: 265Ax (Safety Instructions)
File Type: PDF
File Size: —
Pages: 22
Text of ABB 265Ax Safety Instructions

ABB 265Ax SM 265/7/9 SIL-EN Rev. 02

Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx Instructions for Functional Safety

Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx

SM 265/7/9 SIL-EN Instructions for Functional Safety Table of contents Page 1 Field of application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 User benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 Acr
Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety 1 Field of application Differential pressure, gauge pressure and absolute pressure measurements that shall meet the special safety requirements according to IEC 61508/ IEC 61511-1. The measuring unit meets the requirements regarding • functional safety in accordance with IEC 61508/IEC 61511-1 • explosion protectio
Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety 4 Relevant standards 5 Terms and definitions 6 Determination of the Safety Integrity Level (SIL) The reachable Safety Integrity Level depends on the following safety-related characteristics: • Average probability of failure on demand (PFDav) • Hardware fault tolerance (HFT) • Safe failure fraction (SFF). The spe
Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety IMPORTANT This documentation applies to the transmitter 265xx as a part of a safety function. The following table shows the reachable Safety Integrity Level (SIL) of the entire safety-related system for systems of type B, depending on the safe failure fraction (SFF) and the hardware fault tolerance (HFT). Systems of t
Pressure Transmitter Series 2000T and 265Ax, 265Gx, 265Vx, 265Dx, 265Jx, 267Cx, 269Cx SM 265/7/9 SIL-EN Instructions for Functional Safety 7 Specifications for the safety function NOTICE Refer to chapters "Settings" and "Safety-related characteristics" of this document for the mandatory settings and specifications for the safety function. See the relevant data sheet for the transmitter response time. IMPORTANT An MTTR of 8 hours is specified. Safety-rela