Rohde & Schwarz SMB100B Getting Started

Specifications

Brand: Rohde & Schwarz
Category: Portable Generator
Model: SMB100B (Getting Started)
File Type: PDF
File Size: —
Pages: 60

Read Online

Read the Rohde & Schwarz SMB100B Getting Started online using the built-in PDF viewer.

Text of the manual

This document describes the R&S®SMB100B, stock no. 1400.1000.02 and its

options. © 2018 Rohde & Schwarz GmbH & Co. KG Mühldorfstr. 15, 81671 München, Germany Phone: +49 89 41 29 - 0 Fax: +49 89 41 29 12 164 Email: [email protected] Internet: www.rohde-schwarz.com Subject to change – Data without tolerance limits is not binding. R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. 1422.1045.02 | Version 01 | R&S®SMB100B The following abbreviations are used throughout this manual: R&S®SMB100B is abbreviated as R&S SMB100B, R&S®VISA is abbreviated as R&S VISA

1171.1307.42 - 05

1 Safety Instructions Instrucciones de seguridad Sicherheitshinweise Consignes de sécurité Risk of injury and instrument damage The instrument must be used in an appropriate manner to prevent electric shock, fire, personal injury or instrument damage. ● Do not open the instrument casing. ● Read and observe the "Basic Safety Instructions" delivered as printed brochure with the instrument. ● Read and observe the safety instructions in the following sections. Note that the data sheet may specify additional operating conditions. ● Keep the "Basic Safety Instructions" and the product documentation in a safe place and pass them on to the subsequent users. Riesgo de lesiones y daños en el instrumento El instrumento se debe usar de manera adecuada para prevenir descargas eléctricas, incendios, lesiones o daños materiales. ● No abrir la carcasa del instrumento. ● Lea y cumpla las "Instrucciones de seguridad elementales" suministradas con el instrumento como folleto impreso. ● Lea y cumpla las instrucciones de seguridad incluidas en las siguientes secciones. Se debe tener en cuenta que las especificaciones técnicas pueden contener condiciones adicionales para su uso. ● Guarde bien las instrucciones de seguridad elementales, así como la documentación del producto, y entréguelas a usuarios posteriores.

1171.1307.42 - 05

2 Gefahr von Verletzungen und Schäden am Gerät Betreiben Sie das Gerät immer ordnungsgemäß, um elektrischen Schlag, Brand, Verletzungen von Personen oder Geräteschäden zu verhindern. ● Öffnen Sie das Gerätegehäuse nicht. ● Lesen und beachten Sie die "Grundlegenden Sicherheitshinweise", die als gedruckte Broschüre dem Gerät beiliegen. ● Lesen und beachten Sie die Sicherheitshinweise in den folgenden Abschnitten; möglicherweise enthält das Datenblatt weitere Hinweise zu speziellen Betriebsbedingungen. ● Bewahren Sie die "Grundlegenden Sicherheitshinweise" und die Produktdokumentation gut auf und geben Sie diese an weitere Benutzer des Produkts weiter. Risque de blessures et d'endommagement de l'appareil L'appareil doit être utilisé conformément aux prescriptions afin d'éviter les électrocutions, incendies, dommages corporels et matériels. ● N'ouvrez pas le boîtier de l'appareil. ● Lisez et respectez les "consignes de sécurité fondamentales" fournies avec l’appareil sous forme de brochure imprimée. ● Lisez et respectez les instructions de sécurité dans les sections suivantes. Il ne faut pas oublier que la fiche technique peut indiquer des conditions d’exploitation supplémentaires. ● Gardez les consignes de sécurité fondamentales et la documentation produit dans un lieu sûr et transmettez ces documents aux autres utilisateurs.

Getting Started 1422.1045.02 ─ 01

Contents 1 Preface....................................................................................7 1.1 Key Features......................................................................................... 7 1.2 For Your Safety......................................................................................7 2 Documentation Overview......................................................9 2.1 Getting Started Manual.........................................................................9 2.2 User Manuals and Help........................................................................ 9 2.3 Service Manual......................................................................................9 2.4 Instrument Security Procedures....................................................... 10 2.5 Basic Safety Instructions...................................................................10 2.6 Data Sheets and Brochures...............................................................10 2.7 Release Notes and Open Source Acknowledgment (OSA).............10 2.8 Application Notes, Application Cards, White Papers, etc...............11 3 Preparing for Use.................................................................12 3.1 Putting into Operation........................................................................ 12 3.1.1 EMI Suppression...................................................................................13 3.1.2 Unpacking and Checking the Instrument..............................................14 3.1.3 Accessory List.......................................................................................14 3.1.4 Placing or Mounting the Instrument...................................................... 14 3.1.5 Connecting AC Power...........................................................................17 3.1.6 Turning the Instrument On and Off....................................................... 17 3.1.7 Functional Check.................................................................................. 19 3.1.8 Checking the Supplied Options and Licenses...................................... 20 3.2 Connecting USB Devices...................................................................20 3.3 Setting Up a Network (LAN) Connection.......................................... 21 3.3.1 Connecting the Instrument to the Network............................................21

Getting Started 1422.1045.02 ─ 01

4 Instrument Tour................................................................... 24 4.1 Front Panel Tour..................................................................................24 4.1.1 Touchscreen..........................................................................................25 4.1.2 Utility Keys............................................................................................ 26 4.1.3 On/Standby...........................................................................................26 4.1.4 Function Keys....................................................................................... 27 4.1.5 Keypad..................................................................................................27 4.1.6 Navigation Controls...............................................................................27 4.1.6.1 Rotary Knob..........................................................................................28 4.1.6.2 Editing Keys..........................................................................................28 4.1.6.3 Navigation Keys....................................................................................28 4.1.7 Display Keys......................................................................................... 29 4.1.8 USB Connector.....................................................................................29 4.1.9 RF 50 Ω.................................................................................................30 4.2 Rear Panel Tour...................................................................................31 4.2.1 Connectors............................................................................................31 5 Trying Out the Instrument...................................................34 5.1 Generating an Unmodulated Carrier................................................. 34 5.2 Generating an RF Frequency Sweep Signal.....................................38 5.3 Saving and Recalling Settings...........................................................40 6 Instrument Control.............................................................. 44 6.1 Possible Ways to Operate the Instrument........................................44 6.2 Means of Manual Interaction..............................................................45 6.3 Understanding the Display Information............................................45 6.3.1 Status Bar............................................................................................. 46 6.3.2 Tile Diagram..........................................................................................46 6.3.3 Taskbar................................................................................................. 47

Getting Started 1422.1045.02 ─ 01

6.3.4 Additional Display Characteristics.........................................................48 6.4 Accessing the Functionality.............................................................. 49 6.5 Entering Data.......................................................................................50 6.5.1 Entering Numeric Parameters...............................................................51 6.5.2 Entering Alphanumeric Parameters......................................................52 6.5.3 Undo and Redo Actions........................................................................52 6.6 Getting Information and Help............................................................ 52 6.7 Remote Control...................................................................................54 6.8 Remote Operation over VNC..............................................................55 Index..................................................................................... 56

Getting Started 1422.1045.02 ─ 01

1 Preface The R&S SMB100B is a new high-performance signal generator developed to meet demanding customer requirements. Offering excellent signal characteristic and straightforward and intuitive operation, the signal generator makes signal generation fast and easy. 1.1 Key Features Outstanding key features of the R&S SMB100B are: ● SCPI macro recorder and code generator for generating executable remote control code from manual operating steps (for MATLAB®, CVI, etc.) ● Frequency range from 8 kHz to 1 GHz, 3 GHz or up to 6 GHz ● Excellent SSB phase noise of -134 dBc (meas.) at 1 GHz, 20 kHz offset ● Low wideband noise. For frequencies between 15 MHz and 6 GHz and 30 MHz offset, < 153 dBc (typ.) ● Ultra high output power of 34 dBm (meas.) for 1 GHz ● Compact rack with a height of 2 U and a ¾ 19" width ● Pulse train generation ● 5" Graphical User Interface with touchscreen For more information, see data sheet. 1.2 For Your Safety The R&S SMB100B is designated for the development, production and verifica- tion of electronic components and devices in industrial and laboratory environ- ments. Use the R&S SMB100B only for its designated purpose. Observe the operating conditions and performance limits stated in the data sheet. The product documentation helps you to use the R&S SMB100B safely and effi- ciently. Keep the product documentation in a safe place and pass it on to the sub- sequent users. For Your Safety

Getting Started 1422.1045.02 ─ 01

Safety information is part of the product documentation. It warns you about the potential dangers and gives instructions how to prevent personal injury or dam- age caused by dangerous situations. Safety information is provided as follows: ● In the "Basic Safety Instructions", safety issues are grouped according to sub- jects. For example, one subject is electrical safety. The "Basic Safety Instruc- tions" are delivered with the R&S SMB100B in different languages in print. ● Throughout the documentation, safety instructions are provided when you need to take care during setup or operation. Always read the safety instruc- tions carefully. Make sure to comply fully with them. Do not take risks and do not underestimate the potential danger of small details such as a damaged power cable. For Your Safety

Getting Started 1422.1045.02 ─ 01

2 Documentation Overview This section provides an overview of the R&S SMB100B user documentation. Unless specified otherwise, you find the documents on the R&S SMB100B prod- uct page at: www.rohde-schwarz.com/manual/smb100b 2.1 Getting Started Manual Introduces the R&S SMB100B and describes how to set up and start working with the product. Includes basic operations, typical measurement examples, and gen- eral information, e.g. safety instructions, etc. A printed version is delivered with the instrument. 2.2 User Manuals and Help Contains the description of all instrument modes and functions. It also provides an introduction to remote control, a complete description of the remote control commands with programming examples, and information on maintenance, instru- ment interfaces and error messages. Includes the contents of the getting started manual. The contents of the user manuals are available as help in the R&S SMB100B. The help offers quick, context-sensitive access to the complete information. All user manuals are also available for download or for immediate display on the Internet. 2.3 Service Manual Describes the performance test for checking the rated specifications, module replacement and repair, firmware update, troubleshooting and fault elimination, and contains mechanical drawings and spare part lists. Service Manual

Getting Started 1422.1045.02 ─ 01

The service manual is available for registered users on the global Rohde & Schwarz information system (GLORIS, https://gloris.rohde- schwarz.com). 2.4 Instrument Security Procedures Deals with security issues when working with the R&S SMB100B in secure areas. It is available for download on the Internet. 2.5 Basic Safety Instructions Contains safety instructions, operating conditions and further important informa- tion. The printed document is delivered with the instrument. 2.6 Data Sheets and Brochures The data sheet contains the technical specifications of the R&S SMB100B. It also lists the options and their order numbers and optional accessories. The brochure provides an overview of the instrument and deals with the specific characteristics. See www.rohde-schwarz.com/brochure-datasheet/smb100b 2.7 Release Notes and Open Source Acknowledg- ment (OSA) The release notes list new features, improvements and known issues of the cur- rent firmware version, and describe the firmware installation. The open source acknowledgment document provides verbatim license texts of the used open source software. See www.rohde-schwarz.com/firmware/smb100b Release Notes and Open Source Acknowledgment (OSA)

Getting Started 1422.1045.02 ─ 01

2.8 Application Notes, Application Cards, White Papers, etc. These documents deal with special applications or background information on particular topics. See www.rohde-schwarz.com/application/smb100b Application Notes, Application Cards, White Papers, etc.

Preparing for Use

R&S®SMB100B 12 Getting Started 1422.1045.02 ─ 01 3 Preparing for Use ● Putting into Operation..................................................................................... 12 ● Connecting USB Devices................................................................................20 ● Setting Up a Network (LAN) Connection.........................................................21 3.1 Putting into Operation This section describes the basic steps to be taken when setting up the R&S SMB100B for the first time. Risk of injury due to disregarding safety information Observe the information on appropriate operating conditions provided in the data sheet to prevent personal injury or damage to the instrument. Read and observe the basic safety instructions provided with the instrument, in addition to the safety instructions in the following sections. In particular: ● Do not open the instrument casing. Risk of instrument damage due to inappropriate operating conditions Specific operating conditions are required to ensure accurate measure- ments and to avoid damage to the instrument. Observe the information on appropriate operating conditions provided in the basic safety instructions and the instrument's data sheet. Putting into Operation

Preparing for Use

R&S®SMB100B 13 Getting Started 1422.1045.02 ─ 01 Instrument damage caused by electrostatic discharge Electrostatic discharge (ESD) can damage the electronic components of the instrument and the device under test (DUT). Electrostatic discharge is most likely to occur when you connect or disconnect a DUT or test fixture to the instrument's test ports. To prevent electrostatic discharge, use a wrist strap and cord and connect yourself to the ground, or use a conductive floor mat and heel strap combination. Risk of instrument damage due to inappropriate operating conditions An unsuitable operating site or test setup can damage the instrument and connected devices. Before switching on the instrument, observe the infor- mation on appropriate operating conditions provided in the data sheet. In particular, ensure the following: ● All fan openings are unobstructed and the airflow perforations are unim- peded. The minimum distance from the wall is 10 cm. ● The instrument is dry and shows no sign of condensation. ● The instrument is positioned as described in the following sections. ● The ambient temperature does not exceed the range specified in the data sheet. ● Signal levels at the input connectors are all within the specified ranges. ● Signal outputs are connected correctly and are not overloaded. 3.1.1 EMI Suppression Electromagnetic interference (EMI) may affect the measurement results. To suppress generated Electromagnetic Interference (EMI), ● Use suitable shielded cables of high quality. For example use double-shielded RF, BNC and LAN cables (CAT6 STP). Note: USB cables are of varying and often poor quality. Therefore, check the quality of each individual USB cable as described in the service manual. ● Always terminate open cable ends. Putting into Operation

Preparing for Use

R&S®SMB100B 14 Getting Started 1422.1045.02 ─ 01 Note the EMC classification in the data sheet. 3.1.2 Unpacking and Checking the Instrument Unpack the R&S SMB100B carefully and check the contents of the package. ● Check if all items listed on the delivery note, including this getting started manual, are included in the delivery. ● Check the R&S SMB100B for any damage. If the contents are damaged, immediately contact the carrier who delivered the package. Packing material Retain the original packing material. If the instrument needs to be transpor- ted or shipped later, you can use the material to protect the control ele- ments and connectors. Risk of injury during transportation The carrying handles at the front and side of the casing are designed to lift or carry the instrument. Do not apply excessive force to the handles. If a handle is ripped off, the falling instrument can cause injury. 3.1.3 Accessory List The instrument comes with the following accessories: ● Power cable ● Getting Started printed manual 3.1.4 Placing or Mounting the Instrument The R&S SMB100B is designed for use under laboratory conditions, either on a bench top or in a rack using the standard rackmount kit. Putting into Operation

Preparing for Use

R&S®SMB100B 15 Getting Started 1422.1045.02 ─ 01 Bench top operation If the R&S SMB100B is operated on a bench top, the surface must be flat. The instrument can be used in horizontal position, standing on its feet, or with the sup- port feet on the bottom extended. Risk of injury if feet are folded out The feet can fold in if they are not folded out completely or if the instrument is shifted. Collapsing feet can cause injury or damage the instrument. ● Fold the feet completely in or out to ensure stability of the instrument. Never shift the instrument when the feet are folded out. ● When the feet are folded out, do not work under the instrument or place anything underneath. ● The feet can break if they are overloaded. The overall load on the fol- ded-out feet must not exceed 500 N. Putting into Operation

Preparing for Use

R&S®SMB100B 16 Getting Started 1422.1045.02 ─ 01 Risk of injury when stacking instruments A stack of instruments can tilt over and cause injury if not stacked correctly. Furthermore, the instruments at the bottom of the stack can be damaged due to the load imposed by the instruments on top. Observe the following instructions when stacking instruments: ● Never stack more than three instruments. If you need to stack more than three instruments, install them in a rack. ● The overall load imposed on the lowest instrument must not exceed 500 N. ● It is best if all instruments have the same dimensions (width and length). If you need to stack smaller instruments on the top, the overall load imposed on the lowest instrument must not exceed 250 N. ● If the instruments have foldable feet, fold them in completely. Mounting in a rack The R&S SMB100B can be installed in a rack using a rack adapter kit (Order No. see data sheet). The installation instructions are part of the adapter kit. Putting into Operation

Preparing for Use

R&S®SMB100B 17 Getting Started 1422.1045.02 ─ 01 Risk of instrument damage due to insufficient airflow in a rack If the instrument is run with insufficient airflow for a longer period, the instru- ment overheats, which can disturb the operation and even cause damage. Make sure that all fan openings are unobstructed, that the airflow perfora- tions are unimpeded, and that the minimum distance from the wall is 10 cm. 3.1.5 Connecting AC Power The R&S SMB100B is equipped with an AC power supply connector, that can be operated with different AC power voltages. Once it is connected, the instrument automatically adjusts to the given voltage. Refer to the data sheet for the require- ments of voltage and frequency. There is no need to set the voltage manually or change fuses. The AC supply and power switch is at the rear of the unit. To connect the AC supply ► Connect the R&S SMB100B to the AC power source using the supplied power cable. Note: Since the instrument is designed in compliance with standard EN 61010-1 safety class I, it must only be connected to an outlet that has a ground contact. Characteristics of the AC power supply: ● 100 V to 240 V AC ● 50 Hz to 60 Hz; 400 Hz ● Max 2.1 A 3.1.6 Turning the Instrument On and Off To turn on the R&S SMB100B 1. Connect the instrument to the AC supply. Putting into Operation

Preparing for Use

R&S®SMB100B 18 Getting Started 1422.1045.02 ─ 01 2. Turn on the main AC power switch at the rear panel of the R&S SMB100B (position "I" (on)). The instrument is supplied with AC power. Warm-up time for OCXO When the instrument is switched on, the OCXO requires an extended warm-up time (see data sheet). To start the R&S SMB100B Starting the R&S SMB100B requires that it is connected and turned on. ► At the front panel, press the [On/Standby] key briefly. The instrument boots the operating system and starts the instrument firmware. After booting, the instrument is in the state before the last power off (standby or ready), indicated by the color of the [On/Standby] key's LEDs: ● Green: the R&S SMB100B is running and ready for operation. All modules are power-supplied. ● Orange: the R&S SMB100B is in standby mode (main AC power switch is in position "I"). The standby power mode keeps the power switch circuits and the oven- controlled crystal oscillator OCXO active. In this state, it is safe to switch off the AC power and disconnect the instrument from the power supply. To switch between standby and ready state, briefly press the [On/Standby] key. If a previous session was terminated regularly, the instrument uses the last setup with the relevant instrument settings. ► To set up a new configuration, press the [Preset] key to return the instrument to its defined reset/preset state. Putting into Operation

Preparing for Use

R&S®SMB100B 19 Getting Started 1422.1045.02 ─ 01 To shut down and turn off the R&S SMB100B Risk of losing data If you switch off the running instrument using the rear panel switch or by disconnecting the power cord, the instrument loses its current settings. Fur- thermore, program data can be lost. Press the On/Standby key first to shut down the application properly. 1. Press the [On/Standby] key. The current setup is saved, the operating system shuts down and sets the instrument to standby state. The [On/Standby] LED must be orange. 2. Turn off the main AC power switch at the rear panel of the R&S SMB100B (position "0" (off)). The instrument is no longer supplied with AC power. Turning off the AC power You can leave the AC power on permanently. Switching off is required only if the instrument must be disconnected from all power supplies. 3.1.7 Functional Check When the instrument is switched on, it automatically monitors the main functions. A detected fault is indicated by an "Error" message displayed in the "Info" line of the instrument together with a brief error description. For an in-depth identification of the error, tap on the "Info" indication. In response, a description of the errors is displayed. For more information, refer to the "Troubleshooting and Error Mes- sages" section in the user manual. Apart from the automatic monitoring, the R&S SMB100B provides internal adjust- ments to check correct functioning. See the corresponding sections under "Main- tenance" in the user manual. Putting into Operation

Preparing for Use

R&S®SMB100B 20 Getting Started 1422.1045.02 ─ 01 3.1.8 Checking the Supplied Options and Licenses The instrument can be equipped with both, hardware and firmware options. To check whether the installed options correspond to the options indicated on the delivery note, proceed as follows: 1. Press the [Setup] key. 2. Select "Instrument Assembly > Hardware Config" and "Software / Options". A list with hardware and firmware information is displayed. 3. Check the availability of the hardware options as indicated in the delivery note. For an overview of the available options, refer to the data sheet. 3.2 Connecting USB Devices The USB interfaces of the R&S SMB100B allow you to connect USB devices, including USB hubs directly to the instrument. Due to the large number of availa- ble USB devices, there is almost no limit to the expansions that are possible with the R&S SMB100B. The following list shows various USB devices that can be useful: ● Memory stick for easy transfer of data to/from a computer (for example firm- ware updates) ● Keyboard or mouse to simplify the entry of data, comments, filenames, etc. ● Power sensors of the R&S NRP families All USB devices can be connected to or disconnected from the instrument during operation. Connecting a USB storage device When a USB storage device like a memory stick, a CD-ROM drive, or a hard disk is connected, it is detected automatically. The device is made available as a new drive (/usb). The name of the drive is manufacturer-dependent. Connecting USB Devices

Preparing for Use

R&S®SMB100B 21 Getting Started 1422.1045.02 ─ 01 Connecting a keyboard A keyboard is detected automatically when it is connected. The default keyboard layout is English – US. Connecting a mouse A mouse is detected automatically when it is connected. 3.3 Setting Up a Network (LAN) Connection The R&S SMB100B is equipped with a network interface and can be connected to an Ethernet LAN (local area network). Provided the appropriate rights have been assigned by the network administrator, the interface can be used, for exam- ple: ● To transfer data between a controller and the instrument, for example to run a remote control program. ● To access or operate the instrument from a remote computer using the Ultr@VNC program (or a similar tool, like another VNC client or any Web browser supporting Java). ● To transfer data from a remote computer and back, for example using network folders. ● To use power sensors with netwok capability, e.g. the R&S NRP LAN power sensors. This section describes how to configure the LAN interface. Accessing operating system No access to the operating system is required for normal operation. All necessary system settings can be made in the "Setup" dialog. 3.3.1 Connecting the Instrument to the Network There are two methods to establish a LAN connection to the instrument: ● A non-dedicated network (Ethernet) connection from the instrument to an existing network Setting Up a Network (LAN) Connection

Preparing for Use

R&S®SMB100B 22 Getting Started 1422.1045.02 ─ 01 ● A dedicated network connection (Point-to-point connection) between the instrument and a single computer For addressing, both the instrument and the computer reqiure an IP address. The address information is usually assigned to the devices automatically, depending on the network capabilities. If the IP address is not assigned automatically, see "Assigning the IP Address" in the R&S SMB100B user manual, for information on how to assign the address manually. To set up a network (LAN) connection Risk of network failure Consult your network administrator before performing the following tasks: ● Connecting the instrument to the network ● Configuring the network ● Changing IP addresses Errors can affect the entire network. ► Connect the instrument to the network or to a single PC. If the instrument is connected to the LAN, the operating system automatically detects the network connection and activates the required drivers. By default, the instrument is configured to use DHCP (dynamic host configura- tion protocol) configuration and to obtain the whole address information auto- matically. When connected, the R&S SMB100B displays the address information on the screen. Setting Up a Network (LAN) Connection

Preparing for Use

R&S®SMB100B 23 Getting Started 1422.1045.02 ─ 01 Risk of network connection failure Network cables and cable connectors of poor quality, or failures in the auto- negotiation process, can cause network connection failures. If the network connection to the instrument fails, check the network infra- structure and contact your network administrator. For details, see section "Troubleshooting and Error Messages" in the R&S SMB100B user manual. Setting Up a Network (LAN) Connection

Getting Started 1422.1045.02 ─ 01

4 Instrument Tour The following topics help you to get familiar with the instrument and perform the first steps: ● Chapter 4.1, "Front Panel Tour", on page 24 ● Chapter 4.2, "Rear Panel Tour", on page 31 This section explains the control elements and the connectors of the R&S SMB100B with the aid of the front and rear views. For specifications of the interfaces, refer to the data sheet. 4.1 Front Panel Tour This section provides an overview of the control elements at the front panel of the R&S SMB100B. Most of the connectors are at the rear panel and are described in Chapter 4.2, "Rear Panel Tour", on page 31. Figure 4-1: Front panel view 1 = Utility keys 2 = [On/Standby] 3 = Touchscreen 4 = Function keys 5 = Keypad 6 = Navigation controls 7 = Display keys 8 = USB connector 9 = RF output connector Front Panel Tour

Getting Started 1422.1045.02 ─ 01

4.1.1 Touchscreen The screen at the front panel is the graphical user interface. It shows the settings dialogs and parameters, and the current configuration at a glance, see Chap- ter 6.3, "Understanding the Display Information", on page 45. Figure 4-2: Touchscreen The touch-sensitive panel provides an alternative means of user interaction for quick and easy handling of the instrument, see Chapter 6.2, "Means of Manual Interaction", on page 45. Front Panel Tour

Getting Started 1422.1045.02 ─ 01

Risk of touchscreen damage Inappropriate tools or excessive force can damage the touchscreen. Observe the following instructions when operating the touchscreen: ● Never touch the screen with ball point pens or other sharp objects, use your fingers instead. As an alternative, you can use a stylus pen with a smooth soft tip. ● Never apply excessive force to the screen. Touch it gently. ● Never scratch the screen surface, for example with a finger nail. ● Never rub the screen surface strongly, for example with a dust cloth. For instructions on cleaning the screen, see the Maintenance chapter in the R&S SMB100B user manual. 4.1.2 Utility Keys The utility keys set the R&S SMB100B to a defined state, and provide access to basic settings and information on assistance. Table 4-1: Utility keys Utility Key Assigned functions [Preset] Sets the instrument to a defined state [Local] Switches from remote control to local (manual) control [Setup] Accesses the general instrument settings [Help] Displays context-sensitive help text 4.1.3 On/Standby The [On/Standby] key starts up and shuts down the instrument, and switches between the standby and the ready state. ● In the ready state, On/Standby key lights green. The instrument is ready for operation. ● In the standby state, the On/Standby key lights orange. The standby power mode keeps the power switch circuits and the oven-controlled crystal oscilla- Front Panel Tour

Getting Started 1422.1045.02 ─ 01

tor OCXO active. In this state, it is safe to switch off the AC power and discon- nect the instrument from the power supply. 4.1.4 Function Keys Function keys provide access to the most common generator settings and func- tions. You can find a detailed description of the corresponding functions in the user manual. Table 4-2: Function keys Function key Assigned functions [Freq] Activates frequency entry. [Level] Activates level entry. [Mod on/off] Switches the modulation on and off. [RF on/off] Switches the RF output on and off. 4.1.5 Keypad The keypad enables you to enter alphanumeric parameters, including the corre- sponding units. It contains the following keys: Table 4-3: Keys on the keypad Type of key Description Alphanumeric keys Enter numbers and (special) characters in edit dialog boxes. Decimal point Inserts a decimal point "." at the cursor position. Sign key Changes the sign of a numeric parameter. In the case of an alphanumeric parameter, inserts a "-" at the cursor position. Unit keys (G/n dBμV, M/μ μV, k/m mV and x1 dB(m)) These keys add the selected unit to the entered numeric value and complete the entry. In the case of level entries (e.g. in dB) or dimensionless values, all units have the value "1" as multiplying factor. Thus, they have the same function as an [Enter] key. 4.1.6 Navigation Controls The navigation controls include a rotary knob, navigation keys, and the display keys. They allow you to navigate within the display or within dialog boxes. Front Panel Tour

Getting Started 1422.1045.02 ─ 01

4.1.6.1 Rotary Knob The rotary knob has several functions: ● Increments (clockwise direction) or decrements (counterclockwise direction) the instrument parameter at a defined step size in the case of a numeric entry. ● Moves the selection, e.g. to a function block in the block diagram ● Shifts the selection bar within focused areas (e.g. lists). ● Acts like the [Enter] key, when it is pressed. 4.1.6.2 Editing Keys Editing keys enable you to confirm an entry, delete individual characters, or exit the current operation. Table 4-4: Editing keys Type of key Description [Esc] key Closes all kinds of dialog boxes, if the edit mode is not active. Quits the edit mode, if the edit mode is active. In dialog boxes that contain a "Cancel" button it activates that button. For "Edit" dialog boxes the following mechanism is used: ● If data entry has been started, it retains the original value and closes the dialog box. ● If data entry has not been started or has been completed, it closes the dialog box. [Enter] key Has the same effect as pressing the rotary knob ● Concludes the entry of dimensionless entries. The new value is accepted. ● With other entries, this key can be used instead of the default unit key. ● In a dialog box, selects the default or focused element. ● Calls the next dialog level. ● Confirms and closes open input windows. [Backspace] key Deletes the character to the left of the cursor in editing mode. 4.1.6.3 Navigation Keys As an alternative to the rotary knob or the touchscreen, you can use the naviga- tion keys to navigate through dialog boxes, diagrams, or tables. Front Panel Tour

Getting Started 1422.1045.02 ─ 01

Table 4-5: Navigation keys Type of key Description [Up/Down] Key The [Up] and the [Down] key does the following: ● In a numeric edit dialog box, increase or decrease the instru- ment parameter. ● In a list, scroll forward and backward through the list entries. ● In a table, move the selection bar vertically. ● In windows or dialog boxes with vertical scrollbar, move the scrollbar. [Left/Right] Key The [Left] and the [Right] key does the following: ● In an alphanumeric edit dialog box, move the cursor. ● In a list, scroll forward and backward through the list entries. ● In a table, move the selection bar horizontally. ● In windows or dialog boxes with horizontal scrollbar, move the scrollbar. 4.1.7 Display Keys The display keys arrange different windows on the display. Table 4-6: Display keys Display key Assigned functions [Home] Returns to the initial feature screen. [Next window] Toggles between the entry fields in the taskbar. [On/Off] ● Switches highlighted elements or a function block on and off. ● Switches between two or more settings, e.g. items of selec- tion lists. At the end of a list, the cursor is set on the first entry again. [Undo] Reverts the last operation. [★ (User)] Adds a parameter to the user menu for quick access. 4.1.8 USB Connector USB (universal serial bus) interfaces of type A (host USB). ● Connection of peripherals such as mouse or keyboard ● Connection of memory stick for file transmission ● Firmware update Front Panel Tour

Getting Started 1422.1045.02 ─ 01

Further USB interface type A (host USB) and a USB interface type B (USB In) are available on the rear panel. See also Chapter 3.2, "Connecting USB Devices", on page 20. 4.1.9 RF 50 Ω Output of the RF signal. Maximum input levels Do not overload the RF output. The instrument is equipped with a reverse power protection that prevents the RF output against back feed, see section "Reverse Power Protection" in the user manual. The maximum permissible reverse power is specified in the data sheet. The connector type depends on the installed frequency option. Risk of RF connector and cable damage If you tighten the connectors too strongly, you can damage the cables and connectors. If you do not tighten the connectors enough, the measurement results can be inaccurate. Always use an appropriate torque wrench suitable for this type of connector and apply the torque specified in the application note 1MA99. The application notes are available on the Internet and provide additional information on care and handling of RF connectors. Rohde & Schwarz offers appropriate torque wrenches for various connec- tors. For ordering information, see the R&S SMB100B data sheet or product brochure. Front Panel Tour

Getting Started 1422.1045.02 ─ 01

4.2 Rear Panel Tour This section provides an overview of the connectors at the rear panel of the instrument. For technical data of the connectors, refer to the data sheet. Figure 4-3: Rear panel view R&S SMB100B RF Signal Generator 1 = IEC 625/IEEE 488 connector 2 = USB In connector (type micro-B) 3 = LAN connector 4 = USB connector (type A) 5 = AC power supply connection and main power switch 6 = S/P Dif digital stereo signal input connector (BNC) 7 = Stereo L/R analog stereo modulation signal input connectors (BNC) 8 = Ref In 1GHz and Ref Out 1GHz connectors (SMA) 9 = Ref In and Ref Out connectors (BNC) 10 = LF output connector (BNC) 11 = Mod. Ext. input connector (BNC) 12 = Pulse Video and Pulse Ext. connectors (BNC) 13 = Signal Valid output connector (BNC) 14 = Inst Trig input connector (BNC) 15 = Serial number (six digits in the string 1400.1000.02--) 4.2.1 Connectors IEC 625/IEEE 488 Option: R&S SMBB-B86 GPIB-bus interface for remote control of the instrument. The IEC 625 interface is in compliance with IEEE488 and SCPI. A computer for remote control can be connected via this interface. To set up the connection, we recommend that you use a shielded cable. Note: To avoid electromagnetic interference (EMI) caused by open lines, always terminate any connected IEC-bus cable with an instrument or a controller. Rear Panel Tour

Getting Started 1422.1045.02 ─ 01

See also "Annex: Hardware Interfaces" and chapter "Network and Remote Con- trol" in the user manual. USB/USB In ● Female USB type A connector, to connect devices like a keyboard, a mouse, a memory stick, or the R&S NRP-Z3/Z4 cable for the R&S NRP power sen- sors ● Female USB In connector (USB type B), for example for remote control. Option: R&S SMBB-B86 See also Chapter 3.2, "Connecting USB Devices", on page 20. LAN The LAN interface can be used to connect the R&S SMB100B to a local network for remote control, remote operation, and data transfer. AC supply and power switch The AC power supply connector and the main power switch are located in a unit on the rear panel of the instrument. Main power switch function: ● Position 1: The instrument is in operation. ● Position 0: The entire instrument is disconnected from the AC power supply. For details, refer to Chapter 3.1.6, "Turning the Instrument On and Off", on page 17. S/P Dif Input for digital stereo signals (stereo modulation is available with option R&S SMBB-B5). See also "Stereo Modulation" in the user manual. Stereo L/R Inputs for analog stereo modulation signals. External modulation sources or the internal LF generator can be used (stereo modulation is available with option R&S SMBB-B5). See also chapter "Stereo Modulation" in the user manual. Ref In/Ref Out Input/output for external reference signal. Incl. dedicated connectors for the 1GHz reference signal. Rear Panel Tour

Getting Started 1422.1045.02 ─ 01

Mod. Ext. Input for an external analog modulation signal. Pulse Video Output of the internal pulse generator signal or the looped through pulse signal from Pulse Ext. connector (video signal). Pulse Ext. Input for an external pulse modulation signal or an external trigger/gate signal for the pulse generator. Signal Valid Output signal that marks the valid signal times (valid level and frequency) for all analog modulations. Inst Trig Input for external trigger of sweeps and list mode. Rear Panel Tour

Trying Out the Instrument

R&S®SMB100B 34 Getting Started 1422.1045.02 ─ 01 5 Trying Out the Instrument This chapter introduces the first steps with the R&S SMB100B. It shows how to operate and configure the instrument using simple examples. The complete description of the functionality and its usage is given in the R&S SMB100B user manual. Basic instrument operation is described in Chapter 6, "Instrument Con- trol", on page 44. Prerequisites The instrument is set up, connected to the power supply, and started up as described in Chapter 3, "Preparing for Use", on page 12. The first signal generation tasks explain how to generate an unmodulated signal, to configure the RF signal output, and how you can vary the RF frequency and level in sweep mode. The instrument is manually operated via the touchscreen. Try out the following: ● Generating an Unmodulated Carrier...............................................................34 ● Generating an RF Frequency Sweep Signal...................................................38 ● Saving and Recalling Settings........................................................................ 40 5.1 Generating an Unmodulated Carrier We start to generate a simple unmodulated signal. In this example, the R&S SMB100B can be in its minimal configuration. 1. On the R&S SMB100B front panel, press the [Preset] key to set a defined ini- tial instrument state. 2. Set the frequency: a) In the "Status Bar", tap the "Frequency" field. b) On the on-screen keypad, enter "6" and press the "GHz" key. Generating an Unmodulated Carrier

Trying Out the Instrument

R&S®SMB100B 35 Getting Started 1422.1045.02 ─ 01 The on-screen key pad closes and the frequency value is displayed. 3. To set the signal level, tap the "Level" field and enter the level in the same way. 4. To activate RF signal output, select "Level" > "RF On" in the tile diagram. Generating an Unmodulated Carrier

Trying Out the Instrument

R&S®SMB100B 36 Getting Started 1422.1045.02 ─ 01 The blue colored "RF On" icon indicates that the RF output is activated. The R&S SMB100B provides the 6 GHz signal at the RF connector at the front panel. Generating an Unmodulated Carrier

Trying Out the Instrument

R&S®SMB100B 37 Getting Started 1422.1045.02 ─ 01 Figure 5-1: Generating an unmodulated signal Alternative ways to access the instrument functions To fulfill the same task, you can also use the front panel keys or the setting parameters provided in the frequency and level dialogs. Try out the settings dialogs 1. In the "Frequency" tile, select "Frequency...". a) In the "RF Frequency" tab, tap the "Frequency" field. b) Set the frequency via the on-screen keypad. 2. Access the "RF Level" dialog via the "Level" tile. a) In the "RF Level" tab, select "Amplitude". b) Set the amplitude (level) via the on-screen keypad. 3. Select "RF State > On" to activate the RF signal generation. Try out the front panel keys ► Use the [Freq], [Level], and [RF on/off] key on the front panel. Generating an Unmodulated Carrier

Trying Out the Instrument

R&S®SMB100B 38 Getting Started 1422.1045.02 ─ 01 Connect RF of the R&S SMB100B to a signal analyzer, for example R&S®FSW, to display the generated signal. For the required settings of the signal analyzer, refer to its user manual or its online help. 5.2 Generating an RF Frequency Sweep Signal The "Sweep" operating mode allows you to generate an RF signal with periodi- cally varying frequencies or amplitudes. This example deals with an RF signal with varying frequency and constant level. To configure the sweep, you need to determine a defined start and end frequency with constant time intervals between the frequency steps. The sweep function does not require specific options. 1. On the front panel, press the [Preset] key to set a defined initial instrument state. 2. Set the signal output level, if required, e.g. set "Level > -25 dBm". 3. In the tile diagram, select "Sweep" > "Frequency Sweep". 4. In the "General" tab: Generating an RF Frequency Sweep Signal

Trying Out the Instrument

R&S®SMB100B 39 Getting Started 1422.1045.02 ─ 01 a) Select "Mode > Auto" to run the sweep continuously. b) Select "Shape > Sawtooth" to set the waveform shape of the sweep signal. c) Select "Spacing > Linear", to determine the calculation method for the fre- quency shift of a step. d) Set "Dwell Time > 15.0 ms", to determine the time interval of the sweep steps. 5. Select the "Frequency Range" tab. a) Set "Start Freq > 200 MHz" and "Stop Freq > 600 MHz" to determine the frequency sweep range. b) Set the step width "Step Lin > 10.0 MHz" to determine the width for a fre- quency step. Generating an RF Frequency Sweep Signal

Trying Out the Instrument

R&S®SMB100B 40 Getting Started 1422.1045.02 ─ 01 6. In the "General" tab, activate the frequency sweep with "State > On". 7. Close the sweep dialog. (Alternatively, tap the "Home" button to minimize the dialog. The R&S SMB100B indicates the "Sweep" dialog as active dialog in the task bar.) 8. To activate the RF signal output, select "Level" > "RF On". Figure 5-2: Generating a frequency sweep signal The frequency field in the status bar indicates the continuously changing fre- quency, i.e. the running sweep. 5.3 Saving and Recalling Settings To restore the results of our measurements later, we save the instrument settings in a file. To save the instrument settings in a file We assume, a test configuration as described in Chapter 5.2, "Generating an RF Frequency Sweep Signal", on page 38. 1. Press the [Setup] key on the front panel. Saving and Recalling Settings

Trying Out the Instrument

R&S®SMB100B 41 Getting Started 1422.1045.02 ─ 01 2. In the "Setup" menu, select "Settings > Save/Recall". 3. In the "Save/Recall" dialog, select "Operation Mode > Save". 4. Tap the "Filename", use the on-screen keyboard, and enter MyTestSignal. 5. Tap the "Save" button. The file MyTestSignal.savrcltxt is stored in the default direc- tory /var/user/. To load saved instrument settings You can restore the settings to the instrument at any time using the settings file. 1. Press the [Preset] button to restore the default instrument settings so you can check that the stored user settings are restored afterwards. 2. Press the [Setup] key on the front panel. 3. In the "Setup" menu, select "Settings > Save/Recall". 4. In the "Save/Recall" dialog, select "Operation Mode > Recall". Saving and Recalling Settings

Trying Out the Instrument

R&S®SMB100B 42 Getting Started 1422.1045.02 ─ 01 Navigate to the directory the file is saved in and select the MyTestSignal file. 5. Tap the "Recall" button. All instrument settings are restored and the display resembles Chapter 5.2, "Generating an RF Frequency Sweep Signal", on page 38, which shows the instrument display right before the settings were saved. How to display all parameters with values different to their preset val- ues When you load a file to your instrument, you do not have enough informa- tion on the changed settings. In such case, it is useful to visualize all parameters that have been changed from their default state. Try out the following: ● Touch and hold a spot in the tile diagram for at least 1 second to access the context-sensitive menu. ● Select "Mark All Parameters Changed from Preset". Saving and Recalling Settings

Trying Out the Instrument

R&S®SMB100B 43 Getting Started 1422.1045.02 ─ 01 ● All changed parameters are highlighted. Saving and Recalling Settings

Getting Started 1422.1045.02 ─ 01

6 Instrument Control This chapter provides an overview on how to work with the R&S SMB100B. It covers the following topics: ● Possible Ways to Operate the Instrument.......................................................44 ● Means of Manual Interaction...........................................................................45 ● Understanding the Display Information...........................................................45 ● Accessing the Functionality.............................................................................49 ● Entering Data.................................................................................................. 50 ● Getting Information and Help.......................................................................... 52 ● Remote Control...............................................................................................54 ● Remote Operation over VNC.......................................................................... 55 6.1 Possible Ways to Operate the Instrument There are three ways to operate the R&S SMB100B: ● Manual operation: Use the touchscreen, hard keys and rotary knob, or an optional mouse and/or keyboard. The following description shows how to operate the instrument manually. The description under Chapter 6, "Instrument Control", on page 44 shows how to operate the instrument manually. ● Remote control: Create programs to automatize repeating settings, tests and measurements. The instrument is connected to a computer running the program. This way of operation is described in the user manual, chapter "Network and Remote Control Operation". ● Remote operation from a computer: Remote monitoring and control of the instrument from a connected computer is based on the common cross-platform technology VNC (Virtual Network Computing). On the remote computer, any standard web browser (supporting Java) or a dedicated VNC client (like Ultr@VNC) can be used. See also Chap- ter 6.8, "Remote Operation over VNC", on page 55. Possible Ways to Operate the Instrument

Getting Started 1422.1045.02 ─ 01

6.2 Means of Manual Interaction For the manual interaction with the R&S SMB100B, you have several methods that you can use as an alternative to perform a task: ● Touchscreen: Touchscreen operation is the most direct way to interact. Almost all control elements and actions on the screen are based on the standard operating sys- tem concept. You can tap any user interface element to set parameters in dia- log boxes, enter data, scroll within a dialog etc., as if you work with a mouse pointer. Tapping the screen works like clicking mouse buttons: – Touch quickly = click: Selects a parameter or provokes an action. – Touch and hold = right-click: Opens a context-sensitive menu. – Touch and swipe = drag: Scrolls through the contents of a display element larger than the screen, e.g. a list or a table. ● Function keys and rotary knob: The front panel provides nearly all functions and controls to operate the instru- ment in the classic way, without touchscreen. ● Optional mouse and/or keyboard: These devices work like known from PCs. The navigation keys on the front panel correspond to the keys on the keyboard. This manual describes the manual interaction with the instrument via the touch- screen. It mentions the alternative methods using the keys on the instrument or the on-screen keypads if it deviates from the standard operating procedures. The usage of the touchscreen and navigation keys is described in Chapter 6.4, "Accessing the Functionality", on page 49. Throughout the manual, the term "select" refers to any of the described methods, i.e. using a finger on the touchscreen, a mouse pointer in the display, or a key on the instrument or on a keyboard. 6.3 Understanding the Display Information The home screen of the R&S SMB100B displays all main settings and generator states, divided into three main operation areas. Understanding the Display Information

Getting Started 1422.1045.02 ─ 01

Figure 6-1: Home screen 1 = Taskbar/softkey bar with "Home" and "Info" key 2 = Status bar 3 = Tile diagram ● Status Bar....................................................................................................... 46 ● Tile Diagram....................................................................................................46 ● Taskbar............................................................................................................47 ● Additional Display Characteristics...................................................................48 6.3.1 Status Bar The status bar at the top of the screen indicates the RF frequency and the level of the output signal provided to the DUT. You can set both parameters directly here. 6.3.2 Tile Diagram The tile diagram is the main entry to the settings of the R&S SMB100B. Understanding the Display Information

Getting Started 1422.1045.02 ─ 01

Tile Access to: "Modulation" ● Analog and stereo1), and pulse1) modulation settings ● Built in LF generator "System Config" ● "Save/Recall": settings for saving and loading instrument configura- tions ● "Remote access": Network and emulation settings. ● "Setup": general system configuration "Sweep" ● Frequency and level sweeps ● List mode "Frequency" ● RF frequency and phase ● Reference frequency "Level" ● RF level ● Attenuator ● Automatic level control ● User correction "Power sensors" ● Power sensors 1) requires additional options 6.3.3 Taskbar The "Taskbar" shows a home and an info button, and assigns a labeled button whenever you open a dialog. If more dialogs are open than the taskbar can dis- play, touch and swipe the taskbar to scroll up and down. The buttons shown in the following example represent the variants. Table 6-1: Example of buttons in the taskbar "Home" button Returns to the home screen. "User Menu" Lists parameters that can be defined for quick access. Shows the current remote access connections when the instrument is remotely controlled. Tip: An indicator in the "System Config" tile shows the current remote con- trol status. R&S NRP power sensors Shows a connected external power sensor. The button displays the current readings when the sensor is active. Understanding the Display Information

Getting Started 1422.1045.02 ─ 01

Active dialogs Indicates the dialog name of each active dialog in a separate button. "Info" key Provides access to status and error messages. Note: The warning symbol signifies a permanent error message. 6.3.4 Additional Display Characteristics The following section provides a short insight on the indication of the screen in general, and significant elements that you see under specific operating modes, in dialogs or settings. ● Appearance of active elements – Active elements like On/Off switches, state buttons have a blue back- ground. – Selected elements are framed or highlighted orange. – Inactive elements are gray. ● On-Screen keypads As additional means of interacting with the instrument without having to con- nect an external keyboard, either a numerical or alphanumerical on-screen keypad appears when you activate an entry field (see Chapter 6.5, "Entering Data", on page 50). ● Info line The "Info line" shows brief status information and error messages. It appears when an event generates a message. ● Key parameters indicated in tab labels Most dialogs are divided into tabs with logically grouped parameters. The tab label expresses the content and can also contain status indicators or the set value of a key parameter. ● Scroll bar handle An arrow icon that appears when you touch a scroll bar helps you to scroll in a dialog or list. If no scrollbar handle appears, you can touch and swipe an element to scroll up and down. ● Context-sensitive menus Understanding the Display Information

Getting Started 1422.1045.02 ─ 01

Within the entire screen display, including single parameters, you can access context-sensitive menus that provide some additional functions. 6.4 Accessing the Functionality All functionalities are provided in dialog boxes as known from computer pro- grams. You can control the instrument intuitively with the touchscreen. This sec- tion provides an overview of the accessing methods. The instrument's functions and settings can be accessed by selecting one of the following elements: ● System and function keys on the front panel of the instrument ● Taskbar/softkeys on the touchscreen ● Context-sensitive menus for specific elements on the touchscreen ● Elements on the status bar in the touchscreen ● Displayed setting on the touchscreen, that means block diagram and all set- tings available in dialogs. Accessing the Functionality

Getting Started 1422.1045.02 ─ 01

To open a dialog box ► Perform one of the following actions: ● Tap the required tile, and then the menu entry. ● Tap the minimized view (button) on the taskbar. Some of the utility keys access a dedicated dialog, too. To minimize a dialog box 1. To return to the home screen, tap the "Home" button. 2. To switch to another dialog, press the [Next Window] button. To close a dialog box To close a dialog box, you have the same controls as you know from computers or devices with touchscreen. ► Perform one of the following actions: ● Tap the "Close" icon in the upper right corner. ● Press the [Esc] key on the front panel. ● Drag and drop a minimized dialog from the taskbar to the tile diagram. To select an option in a dialog box ► Tap the required option. 6.5 Entering Data Some parameters have their own key on the front panel. For data input in dialog boxes, the instrument provides on-screen keypads for entering numeric and alphanumeric values. Thus, you can always set the param- eters via the touchscreen, the front panel, or an external keyboard. Correcting an entry 1. Using the arrow keys, move the cursor to the right of the entry you want to delete. 2. Press the [Backspace] key. Entering Data

Getting Started 1422.1045.02 ─ 01

3. Deletes the entry to the left of the cursor. 4. Enter your correction. Completing the entry ► Press the [Enter] key or the rotary knob. Aborting the entry ► Press the [Esc] key. The dialog box closes without changing the settings. 6.5.1 Entering Numeric Parameters To enter values with the on-screen keypad For numeric settings, the instrument displays the numeric keypad. The units specified correspond to the units of the parameter. 1. Enter the numeric value. 2. Tap the unit button to complete the entry. The unit is added to the entry. 3. If the parameter does not require a unit, confirm the entered value by pressing "Enter". To enter values by using the front panel controls 1. Change the currently used parameter value by using the rotary knob or the [Up/Down] keys. 2. If the parameter does not require a unit, confirm the entered value by pressing the [Enter] key or any of the unit keys. The instrument highlights the editing line to confirm the entry. If you edit numeric data in tables, the entry field must be in edit mode: Press [Enter], or the rotary knob to activate the edit mode. Entering Data

Getting Started 1422.1045.02 ─ 01

6.5.2 Entering Alphanumeric Parameters If a field requires alphanumeric input, you can use the on-screen keyboard to enter letters and (special) characters. 6.5.3 Undo and Redo Actions Accessed via the context-sensitive menus, "Undo" allows you to restore one or more actions on the instrument. Depending on the available memory, the "Undo" steps can restore all actions. "Redo" restores a previously undone action. 6.6 Getting Information and Help In some dialog boxes, graphics are included to explain the way a setting works. For further information, you can use the following sources: ● Tooltips give the value range of the parameter. ● The context help provides functional description on a setting. ● The general help explains a dialog box, provides instructions, and general information. To display context help ► To access a help topic, perform one of the following: a) Tap and hold the parameter for which you need information and tap "Help" in the context menu. b) Tap the parameter and press the [Help] key. The "Help" dialog opens. You can browse the help for further information. Getting Information and Help

Getting Started 1422.1045.02 ─ 01

Contents of the help dialog box The help dialog box covers two main areas: ● "Contents" - contains a table of help contents ● "Topic" - contains a specific help topic The help system also provides an "Index" and a "Find" area, and "Zoom" func- tions that are accessed via the corresponding buttons. To open general help ► Press the yellow [Help] key on the front panel. If a dialog box is opened, the help topic for the current tab is shown. Other- wise the "Contents" page appears. Navigating in the table of contents and in the help topics 1. To move through the displayed contents entries, tap on an entry and scroll or use a connected mouse or the [Up/Down] keys. Entries with a plus sign contain further entries. 2. To display a help topic, tap on the topic name or double click on the topic name or press the [Enter] key. Getting Information and Help

Getting Started 1422.1045.02 ─ 01

3. To follow a cross-reference, tap on the link text. 4. To return to the previous page, select "Back". This function scrolls back all steps you have performed before. 5. Use the "scroll bars" to shift the visible section of content shown. 6. To maximize the "Topics" area, tap the "Hide Contents Tree" button to hide the contents tree. Using the index 1. Select the "Index" button. 2. Enter the first characters of the topic you are interested in. The entries starting with these characters are displayed. 3. Tap on the index entry. The corresponding help topic is displayed. 6.7 Remote Control In addition to working with the R&S SMB100B interactively, located directly at the instrument, it is also possible to operate and control it from a remote PC. The R&S SMB100B supports various methods for remote control: ● Connecting the instrument to a (LAN) network (see Chapter 3.3, "Setting Up a Network (LAN) Connection", on page 21) ● Using the LXI browser interface in a LAN network ● Connecting a PC via the IEC-bus (IEEE 488) interface ● Remote control via the USB interface For remote control over LAN or USB, you can use the R&S VISA (Virtual Instrument Software Architecture) library provided for download at the Rohde & Schwarz website http://www.rohde-schwarz.com/rsvisa. How to configure the remote control interfaces is described in the user manual, chapter "Network and Remote Control Operation". Remote Control

Getting Started 1422.1045.02 ─ 01

6.8 Remote Operation over VNC The VNC is an application which can be used to access and control the instru- ment from a remote computer through a LAN connection. While the instrument is in operation, the instrument screen contents are displayed on the remote com- puter, and VNC provides access to all applications, files, and network resources of the instrument. Thus, remote operation of the instrument is possible. Instrument control from a remote computer To access the basic utility functions of the R&S SMB100B, perform a right mouse click on the block diagram and select "Key Emulation". A key panel to the right of the block diagram gives access to the utility func- tions provided by the front panel keys. The VNC is an add-on program, included in operating system Linux/Unix, and available as a free-of-charge download on the internet. For more information, refer to the R&S SMB100B user manual, chapter "How to Set Up Remote Operation via VNC". Remote Operation over VNC

Getting Started 1422.1045.02 ─ 01

Index A AC supply ................................................ 17 Active elements ....................................... 48 Alphanumeric parameters ....................... 52 Application cards ..................................... 11 Application notes ..................................... 11 Auto-negotiation see Autonegotiation ............................ 23 Autonegotiation Failure .................................................23 B Brochures ................................................ 10 C Connector AC power supply .................................32 GPIB ................................................... 31 IEC/IEEE .............................................31 Inst Trig ............................................... 33 LAN .....................................................32 Mod. Ext. .............................................33 Pulse Ext. ............................................33 Pulse Video .........................................33 Ref In .................................................. 32 Ref Out ............................................... 32 RF ....................................................... 30 S/P Dif .................................................32 Signal Valid ......................................... 33 Stereo L/R ...........................................32 USB .............................................. 29, 32 USB In ................................................ 32 Context-sensitive menu ...........................48 D Data entry ................................................50 Data sheets ............................................. 10 Dialog boxes ............................................49 Display Active elements .................................. 48 Context-sensitive menu ...................... 48 Info line ............................................... 48 Information ..........................................45 On-screen keypad .............................. 48 Overview .............................................25 Status bar ........................................... 46 Tab labels ............................................48 Taskbar ............................................... 47 Tile diagram ........................................ 46 Documentation overview ........................... 9 E Electrostatic discharge ............................ 13 EMI suppression ......................................13 Emulating front panel keys ...................... 55 ESD ......................................................... 13 F Failure Network connection ............................ 23 Front panel tour ....................................... 24 Function check ........................................ 19 Function keys Details - see user manual ................... 27 Overview .............................................27 G Getting started ...........................................9 H Help ..................................................... 9, 52 I Info line ....................................................48 Input connector ........................................33 Input connectors Mod. Ext. .............................................33 S/P Dif .................................................32 Stereo L/R ...........................................32 Instrument control ....................................44 Instrument help ..........................................9 Instrument security procedures ............... 10 Instrument tour ........................................ 24 K Key ★ (User) ..............................................29 Access on a remote computer ............ 55 Arrow .................................................. 28 Backspace .......................................... 28 Down ...................................................28 Emulation ............................................55

Getting Started 1422.1045.02 ─ 01

Enter ................................................... 28 Esc ......................................................28 Freq .................................................... 27 Help .................................................... 26 Home .................................................. 29 Left ......................................................28 Level ................................................... 27 Local ................................................... 26 Mod on/off ...........................................27 Next window ....................................... 29 On/Off ................................................. 29 On/Standby .........................................26 Preset ................................................. 26 Resize window ....................................29 RF on/off ............................................. 27 Right ................................................... 28 Setup .................................................. 26 Up ....................................................... 28 Keyboard On-screen ........................................... 50 Usage ................................................. 45 Keypad On-screen ........................................... 50 Overview .............................................27 L LAN configuration ....................................21 LAN connection Not working .........................................23 Loading Trying out ............................................ 41 M Manual interaction ................................... 45 Mod. Ext. connector ................................ 33 Mounting Rack ....................................................16 Mouse Usage ................................................. 45 N Navigation Keys ....................................................28 Navigation controls Overview .............................................27 Network connection Error ....................................................23 Numeric data entry .................................. 50 Numeric parameters ................................51 O On-screen keyboard ................................52 On-screen keypad ................................... 48 Open source acknowledgment (OSA) .....10 Operation Manual ................................................ 45 Output connector .....................................33 Output connectors RF ....................................................... 30 P Parameters Entering ........................................ 51, 52 Power On ................................................ 26 Power supply Connector ........................................... 32 Power switch ........................................... 17 R Rack Mounting ............................................. 16 Ready state ............................................. 18 Release notes ......................................... 10 Remote access see Remote operation from a computer ............................................................44 Remote connection Not working .........................................23 Remote control ........................................ 54 Remote operation ....................................55 RF connector ...........................................30 Rotary knob ............................................. 28 S S/P Dif connector .................................... 32 Safety instructions ................................... 10 Saving ..................................................... 40 Service manual ..........................................9 Shutting down ..........................................19 Softkey bar see Taskbar ........................................ 47 Standby ............................................. 18, 26 Starting .................................................... 18 Status bar Display ................................................ 46 Stereo L/R connector .............................. 32 T Tab labels ................................................ 48

Getting Started 1422.1045.02 ─ 01

Text entry .................................................50 Tile diagram Display ................................................ 46 Tooltips Show ...................................................52 Touchscreen ............................................ 25 Compared with mouse ........................45 Usage ................................................. 45 Turn on .................................................... 17 U User manual .............................................. 9 Utility keys Details - see user manual ................... 26 Overview .............................................26 V VNC Using in a LAN ....................................55 W White papers ........................................... 11

Other Portable Generator Manuals