Roger RWL-2 Operating Manual
Text of the manual
Roger Access Control System
RWL-2 Wireless Lock
Operating Manual
Firmware version: 1.0
Document version: Rev. C
RWL-2 Operating Manual.doc
2018-06-29
2/17
DESIGN AND APPLICATION
RWL-2 lock enables read-in access control based on MIFARE proximity cards. The lock can be
operated in Online mode within RACS 5 access control system or in Offline mode as standalone
device. In the Online mode access decisions are made on the access controller to which lock is
connected. In the Offline mode, based on the card numbers stored in its memory, the lock decides
autonomously if the access can be granted. For the time when connection to access controller is lost
RWL-2 automatically switches to Offline mode.
The RWL-2 lock consists of two escutcheons with handles. Card reader is installed in the external
escutcheon while the battery pack is installed in the internal one. The internal handle is permanently
coupled with latch and door can be always open without use of electronics. The external handle is
separated from the latch and moves freely. When the access is granted the electronic module couples
the external handle with latch to enable door opening. The RWL-2 lock can be optionally equipped
with door cylinder and then be opened from the outside with traditional metal key. Optionally the
RWL-2 can be equipped with external door contact and mortise deadbolt contact. Statuses of these
detectors are reported to the access controller. The wireless lock is supplied by 4 AAA batteries. Low
battery level can be signalled locally and reported to the access controller. The batteries enable one
year operation for average 10 opening cycles per day.
Depending on door opening direction and handle location on the door leaf the adequate type of RWL-
2 lock must be applied.
Version
Description
RWL-2-L
Left hand door, left hand reverse door
RWL-2-R
Right hand door, right hand reverse door
Fig 1. RWL-2-L installation scenarios (view from the outside)
RWL-2 Operating Manual.doc
2018-06-29
3/17
Fig. 2. RWL-2-R installation scenarios (view from the outside)
Mechanical construction
External part of RWL-2
The external part of RWL-2 consists of escutcheon with handle and it is dedicated to installation at the
entry to controlled room. The escutcheon includes card reader (A) and hole for door cylinder which
can be used for emergency door opening with mechanical key. The electronic module which is located
inside the escutcheon includes service contact (B) and programming contacts (C). Wires with plug (E)
are used to connect the module with battery pack. Three isolated wires (F) ended with heat shrinkable
sleeve are used to connect external deadbolt and door contact. The status of the contacts is
represented by DEADBOLT and DOOR CONTACT input in RACS 5 system.
Fig. 3. RWL-2 entry escutcheon
RWL-2 Operating Manual.doc
2018-06-29
4/17
Fig. 4. Electronic module inside entry escutcheon
Internal part of RWL-2
The internal part of RWL-2 consists of escutcheon with handle and it is dedicated to installation at the
exit from controlled room. The internal escutcheon includes battery pack. In order to replace batteries
remove hex screw and battery cover. Wires with plug (G) are connected to socket (E) at external
escutcheon in order to supply it.
Fig. 5. RWL-2 exit escutcheon
Door cylinder
RWL-2 lock enables installation of a lock cylinder. Such cylinder enables emergency door opening from
the outside using metal key. The size of cylinder depends on door thickness and it must be selected in
such way that it would not protrude by more than 16mm over door surface of inside and in range 21-
24 from outside.
RWL-2 Operating Manual.doc
2018-06-29
5/17
FUNCTIONAL DESCRIPTION
The RWL-2 can be used as autonomous access control point, where the access is granted based on
the data stored in the lock’s memory, or as a networked access point operating in the on-line access
control system. In the Online mode access is controlled by the external controller. Transmission
between the lock and controller is wireless and requires intermediary RWH-1 hub. Regardless of the
selected working mode (online or offline) the lock requires configuration which can be done from the
programming computer with the RogerVDM application and connected to the lock through RUD-1
communication interface. If the lock is designated to operate in Offline mode with list of 50 users,
each equipped with Main card and Backup card, it can be programmed manually without computer. In
this scenario, two programming cards, called ADD card and DEL card, are used to program the unit.
Proximity cards
The lock is equipped with a card reader which supports MIFARE® Ultralight/Classic/DESFire/Plus
cards. Factory configured device reads card serial number (CSN - Chip Serial Number), but using
RogerVDM software it can be configured to use programmable card number (PCN – Programmable
Card Number) stored in the encrypted memory of the MIFARE card.
Card number
The card number which RWL-2 lock reads from the card and returns to the access controller is called
RCN (Returned Card Number). In general, the RCN can be composed of two sections:
• CSN section
• PCN section
The CSN section is a part of the RCN card number taken from the card serial number (CSN). The
serial number is programmed by card manufacturer.
The PCN section is a part of the RCN card number taken from the card’s programmable memory. The
programmable number can be encrypted with own key in order to enable protection against card
copying.
Using RogerVDM program, installer can define the method used to read card number. It is possible to
operate solely with CSN or PCN number, or combination of both (CSN+PCN). By default, lock utilizes
CSN number.
Note: Due to relatively easy copying of the card serial number (CSN), it is recommended to configure
the lock for operation with programmable card number (PCN). If so, cards have to be programmed in
the way which corresponds with lock’s card number configuration.
Offline mode
In the Offline mode, the lock grants access for cards stored in its memory. The lock can operate
permanently in Offline mode or enter this mode temporary, when operating in Online mode but
wireless connection with controller is lost.
Up to 100 cards can be defined and stored in lock’s memory. Each card can be authorised for
momentary door opening (option: Normal access) and/or to open the door for unlimited time (option:
Office access). If the card is authorized for Normal access then it opens the lock for the time specified
by the parameter Lock pulse. If the card is authorized for Office mode then it can open the lock for
unlimited time. When lock is switched to Office mode door can be open without use of a card. If the
card is authorised for Normal access and Office mode then in order to get access it shall be used once
while in order to activate Office mode it shall be used twice.
Backup cards
Up to 100 cards can be defined and stored in lock’s memory. Each card can belong to individual user.
Optionally the lock can operate with 50 users only. In such a case each user can have two cards: Main
card and Backup card . Both cards have the same authorizations. Factory new lock is configured to
RWL-2 Operating Manual.doc
2018-06-29
6/17
operate with 50 users. This mode is also used in case of restoring lock’s default settings. Switching to
100 users mode can be done by means of RogerVDM software.
The Backup cards are dedicated to installations where lock is programmed manually. Thanks to the
Backup card it is possible to remove selectively Main card from the lock’s memory even thou it is not
physically available (e.g. lost or damaged). If the Backup card is not available then in order to remove
lost or stolen Main card it is necessary to clear entire lock’s memory and program all cards from the
scratch. To assure availability of Backup cards they should be properly marked and stored.
Note: Backup card is assigned with same authorizations as accompanying Main card and can be used
on the same rules as the Main card.
Online mode
In the Online mode, the lock is wirelessly connected to access controller which controls the access to
the room. Cards and inputs are reported to the controller which makes decision about access.
In case when wireless connection is lost, the lock automatically switches to Offline mode and
continues operation based on its internal configuration settings. When the wireless connection is
restored then the lock automatically returns to Online mode.
Radio channels
The wireless communication utilizes the IEEE 802.15.4/ 2.4GHz band which is shared with Wi-Fi
networks. If the lock uses the same channel as Wi-Fi network then in case of intensive Wi-Fi
transmission the lock may occasionally lose communication with the hub. Prior to wireless system
installation it is recommended to verify what channels are occupied by local Wi-Fi networks and use
those which are free. Radio channel scanning can be made using popular mobile apps.
Wi-Fi channels (according to IEEE 802.11)
Channel
Frequency range [GHz]
Channel
Frequency range [GHz]
1
2,401 - 2,423 (2,412)
8
2,436 - 2,458 (2,447)
2
2,406 - 2,428 (2,417)
9
2,441 - 2,463 (2,452)
3
2,411 - 2,433 (2,422)
10
2,446 - 2,468 (2,457)
4
2,416 - 2,438 (2,427)
11
2,451 - 2,473 (2,462)
5
2,421 - 2,443 (2,432)
12
2,456 - 2,478 (2,467)
6
2,426 - 2,448 (2,437)
13
2,461 - 2,483 (2,472)
7
2,431 - 2,453 (2,442)
14
2,473 - 2,495 (2,484)
RACS AIR channels (according to IEEE 802.15.4)
Channel
Frequency [GHz]
Channel
Frequency [GHz]
11
2,405
19
2,445
12
2,410
20
2,450
13
2,415
21
2,455
14
2,420
22
2,460
15
2,425
23
2,465
16
2,430
24
2,470
17
2,435
25
2,475
RWL-2 Operating Manual.doc
2018-06-29
7/17
18
2,440
26
2,480
LED indicators
RWL-2 lock is equipped with 4 LED indicators which functions are described in the table below.
LED indicators
Name
Colour
Description
LED RED
Red
Online mode: the function of this LED is programmed in VISO
management software.
Offline mode: indicator is blinking when lock waits for the
optional second card reading. If it occurs, lock switches to Office
mode.
LED GREEN
Green
In Online mode the function of this LED is programmed in VISO
management software.
In Offline mode the indicator is not used.
LED BLUE
Blue
Online mode: the indicator is controlled by access controller in
accordance with the logic applied in the RACS 5 system.
If the lock switches to Offline mode due to communication
failure then LED BLUE is operated as lock was in Offline mode
except that it blinks instead of steady light.
The indicator blinks slowly if wireless communication is not
configured.
In Offline mode the indicator:
• 2 sec pulse when access is granted and external
handle is coupled
• two 2 sec pulses when access is denied
• lights steadily when operates in Office mode
LED
SYSTEM
Orange
• lights steadily in case of lock’s configuration error
• pulses slowly in case of low battery level (batteries
must be replaced)
• pulses every 2 sec when wireless connection is being
established in Online mode
Power supply
RWL-2 lock is supplied from 4 pcs of AAA batteries. In case of average 10 operations daily the alkaline
batteries enable 1 year functioning. Low battery level is reported to VISO management software and
additionally it is signalled locally by orange LED SYSTEM pulsing and acoustic signal generated prior to
entering standby mode.
CONFIGURATION
RWL-2 lock can be programmed manually or from PC computer. Manual programming enables card
management for Offline mode only. All configuration settings can be setup and edited using
RogerVDM program. Connection to PC requires RUD-1 interface.
Factory new lock is configured for Offline mode and includes 2 programming cards (ADD card and DEL
card). Lock pulse by default is set to 2 sec while built-in RFID reader is configured to read card serial
numbers (CSN).
RWL-2 Operating Manual.doc
2018-06-29
8/17
Factory cards
Label
Name
Authorization
ADD
ADD programming card
New card adding to the lock
DEL
DEL programming card
Card deleting from the lock
Configuration recovery from the lock
In some circumstances it might be required to recover the configuration settings from the lock. Such
operation can be done by means of RogerVDM software. Regardless of the operating mode it is not
possible to recover communication password and card encryption keys. Recovery of the user cards
programmed in the lock’s memory, can be disabled by means of Card codes protection option, which
by default is set off so the card codes can be read from the lock’s memory.
Note: Once the Card code protection option is set, the only way to clear it is to execute memory reset
which erases entire lock’s memory.
Manual programming of the users
If the lock operates in Offline mode then it can be configured manually without computer. Using
manual programming it is possible to add and delete user cards. Factory new lock is configured for
Offline mode with Backup cards and delivered with 2 programming cards (ADD card and DEL card).
The manual programming of the users can be used either when lock operates with Backup cards (50
users limit) or without Backup cards (100 users limit). When lock operates with 100 user limit,
programming steps related to the Backup cards shall be skipped.
Note: It is possible to program new ADD and DEL programming cards during memory reset
procedure.
User adding
A. Read ADD programming card.
B. Read first card to program user’s Main card.
C. Read second card to program user’s Backup card.
Notes:
• New user shall be granted Office access if step A is repeated twice.
• New user shall be granted Normal access and Office access if step A is repeated thrice.
• If Backup card is not needed then read ADD programming card again in step C.
• If already programmed card is used in step B or C then the lock shall generate 2 sec
acoustic warning and shall finish programming procedure.
Example: Programming of user with Normal access
• Read ADD programming card once.
• Read first card to program user’s Main card.
• Read second card to program user’s Backup card.
• Wait till 3 acoustic beeps are generated by lock and then you can continue with more cards
programming.
Example: Programming of user with Office access
• Read ADD programming card twice.
• Read first card to program user’s Main card .
• Read second card to program user’s Backup card .
RWL-2 Operating Manual.doc
2018-06-29
9/17
• Wait till 3 acoustic beeps are generated by lock and then you can continue with more cards
programming.
Example: Programming of user with Normal access and Office access
• Read ADD programming card thrice.
• Read first card to program user’s Main card.
• Read second card to program user’s Backup card.
• Wait till 3 acoustic beeps are generated by lock and then you can continue with more cards
programming.
User deleting
A. Read DEL programming card.
B. Read Main card or Backup card to remove both cards from the lock’s memory.
Note: All cards can be removed from memory using memory reset procedure.
Example: User deleting
• Read DEL programming card.
• Read Main card or Backup card to remove both cards from the lock’s memory.
• Wait till 3 acoustic beeps are generated by lock and then you can continue with more cards
programming.
Programming with RogerVDM software
RogerVDM software enables full configuration of the lock operated either in Online mode or Offline
mode. In case of Offline mode it is also possible to configure list of 100 users with Main cards instead
of default list of 50 users with Main cards and Backup cards. The selection of user limit is done with
the parameter Backup cards. When the option is set to [1]: Yes then lock operates with 50 users limit.
Note: It is recommended to backup RWL-2 settings, save them to file and protect against loss and
access of unauthorized persons.
The procedure below includes steps required to configure the lock using computer and RogerVDM
software.
1. Place jumper on MEM pins.
2. Connect the lock to RUD-1 interface using dedicated cable (fig. 6).
3. Short RST pins for a moment preferably by placing and removing jumper – Orange LED
SYSTEM shall pulsate.
4. In RogerVDM select Device/New and then select type of device (RWL-2) and serial COM
port with RUD-1 interface.
5. Select required settings.
6. Make backup by saving settings to file (button: Send to File…).
7. Upload settings to the lock (button: Send to device).
8. In RogerVDM select Device/Disconnect.
9. Remove jumper from MEM pins.
10. Short RST pins for a moment preferably by placing and removing jumper.
11. The lock is ready for operation.
RWL-2 Operating Manual.doc
2018-06-29
10/17
Note: The jumper can be left on MEM pins. If so the lock can be later configured remotely using
wireless method.
Fig. 6. Connection of lock to the RUD-1 interface
RogerVDM commands
The table below includes commands which are available in RogerVDM software for RWL-2 lock.
Command/button
Description
Tab: Configuration
Load defaults
Restore default settings
Read from File…
Load backup configuration
Send to File...
Save backup configuration
Read from Device
Reads configuration from device
Send to Device
Upload configuration to device
Tab: Credentials
Add
Adds new user
Edit
Edit existing user
Delete
Delete existing user
Delete all
Delete all users
Read from file
Read users list from file
Write to file
Save users list to file
Read from device
Read users list from device
Send to device
Save users list to device
Tab: Tools
Erase RACS AIR...
Erase configuration of RACS AIR network
RWL-2 configuration parameters in RogerVDM
The table below includes RWL-2 configuration parameters which can be modified using RogerVDM
software within low level configuration of device (tab: Configuration ).
Parameter
Function
RWL-2 Operating Manual.doc
2018-06-29
11/17
General settings
Operating mode
The parameter enables selection of Offline mode or Online mode.
Default value: Offline.
LED SYSTEM flash after card
read
When option is set then card reading is confirmed with flash on
LED SYSTEM. Default value: Yes.
Short sound after card read
When option is set then card reading is confirmed with short
acoustic beep. Default value: Yes.
LED SYSTEM pulsing when
card close to the reader
When option is set then orange LED SYSTEM pulses whenever card
is detected near the reader. Default value: No.
Battery low level signalisation
When option is set then lock signals low battery level by orange
LED SYSTEM indicator pulsing and series of 5 acoustic beeps after
card reading. Default value: Yes.
Buzzer loudness level
The parameter defines loudness level of the built-in buzzer. When
set to zero then buzzer is disabled. Default value: 100%
Offline mode
Lock pulse [s]
The parameter defines lock opening time when access is granted.
Default value: 2s.
ADD programming card
The card code of the ADD programming card.
DEL programming card
The card code of the DEL programming card.
Backup cards
When option is on, then each user programmed in the lock can
have both Main card and Backup card. When the option is off then
each user can have the Main card only. Default value: Yes.
Card codes protection
When option is set then it is not possible to read user card codes
from the lock’s memory. Once option is set it can be cleared by
memory reset procedure only. The purpose of the option is to
prevent unauthorized person to read card numbers from the lock’s
memory. Default value: No.
Online mode
Wireless settings
Device MAC address
Factory set RWL-2 lock identification number.
Hub MAC address
The identification number of the wireless hub (e.g. RWH-1) to
which lock may connect.
Radio channels
Radio channels enabled to be used by lock. It is recommended to
allow all channels on the lock and restrict radio channels on the
hub. Default value: all channels available.
Network identifier
The identification number of the wireless network in which lock
operates (PAN ID). Each network working on the same radio
channel should be assigned with unique PAN ID. The range of
available values is 0-16. Optionally the parameter can be set to
AUTO. In such case the hub shall select PAN ID automatically.
Default value: AUTO.
Encryption key
Encryption key used for wireless communication. In case of
recommended empty field the key shall be defined and applied
automatically when the network is defined. Default value: Auto.
Notification time [s]
The parameter defines how often the lock shall wake from standby
mode and shall communicate with hub to confirm its availability in
RWL-2 Operating Manual.doc
2018-06-29
12/17
the network. The shorter is the notification time the more often
communication is established and batteries are discharged quicker.
Default value: 60s.
Registration time [s]
The parameter defines the time necessary to read card at the lock
in order to add the lock to the network. If the time is exceeded
then lock adding procedure must be started from the beginning.
This parameter concerns network establishing procedure only.
Default value: 600s.
Network restore attempt time
[min.]
The parameter defines time between consecutive attempts to
restore wireless communication with the hub when it is broken due
to some reason. Default value: 30min.
Radio channel
The parameter indicates radio channel used by the lock. This
parameter is read-only and appears only if the lock is successfully
enrolled into the network.
Network ID
The parameter indicates network ID (PAN ID) in which lock
operates. This parameter is read-only and appears only if the lock
is successfully enrolled into the network.
Comments
DEV comment
Any text to be displayed in VISO management software in order to
facilitate object identification. DEV object represents the whole
device (wireless lock). Default value: RWL-2.
DEADBOLT comment
Any text to be displayed in VISO management software in order to
facilitate object identification. DEADBOLT object represents input
which monitors deadbolt position (if installed). Default value:
Deadbolt.
DOOR CONTACT comment
Any text to be displayed in VISO management software in order to
facilitate object identification. DOOR CONTACT object represents
input which monitors door contact (if installed). Default value:
Door contact.
LED RED comment
Any text to be displayed in VISO management software in order to
facilitate object identification. LED RED object represents output
which controls LED RED. Default value: LED red.
LED GREEN comment
Any text to be displayed in VISO management software in order to
facilitate object identification. LED GREEN object represents output
which controls LED GREEN. Default value: LED green.
LED SYSTEM comment
Any text to be displayed in VISO management software in order to
facilitate object identification. LED SYSTEM object represents
output which controls orange LED SYSTEM. Default value: LED
system.
LOCK comment
Any text to be displayed in VISO management software in order to
facilitate object identification. LOCK object represents output which
controls the lock’s servomechanism. Default value: Lock.
BUZZER comment
Any text to be displayed in VISO management software in order to
facilitate object identification. LOCK object represents output which
controls the internal buzzer. Default value: Buzzer.
CDI comment
Any text to be displayed in VISO management software in order to
facilitate object identification. CDI object represents lock’s built-in
card reader. Default value: CDI.
PWR comment
Any text to be displayed in VISO management software in order to
RWL-2 Operating Manual.doc
2018-06-29
13/17
facilitate object identification. PWR object represents lock’s power
supply i.e. 4 x AA batteries. Default value: PWR.
Input types
DEADBOLT
The parameter defines DEADBOLT input type (NO or NC). Default
value: NO.
DOOR CONTACT
The parameter defines DOOR CONTACT input type (NO or NC).
Default value: NC.
Input response time
DEADBOLT
Parameter defines minimal duration of pulse [ms] which is required
to trigger the input DEADBOLT. Default value: 50ms.
DOOR CONTACT
Parameter defines minimal duration of pulse [ms] which is required
to trigger the input DOOR CONTACT. Default value: 50ms.
Reader settings
Reader object type
The parameter defines type of data returned to controller by lock’s
card reader. Based on this parameter the controller recognizes
card number. Default value: 40 bit number.
Advanced card read settings
CSN length
The parameter defines number of bytes taken from the card serial
number (CSN) and applied in the returned card number (RCN).
Default value: 8.
Mifare Classic settings
Sector type
When the parameter is enabled then returned card number (RCN)
is composed of two parts: the programmable card number (PCN)
and the card serial number (CSN).
When the option is disabled then the returned card number (RCN)
is composed of the card serial number (CSN) only.
Default value: None.
Format
The format of the programmable card number (PCN) stored in the
card’s memory. Default value: BIN.
First byte position (FBP)
The parameter specifies the position of the most significant byte
(MSB) of programmable card number (PCN). Default value: 0.
Last byte position (LBP)
The parameter specifies the position of the least significant byte
(LSB) of programmable card number (PCN). Default value: 7.
Sector ID
The parameter specifies sector number in card’s memory where
programmable card number (PCN) is stored. Default value: 0.
Application ID
The parameter Application ID (AID) is located in card’s MAD sector
and it specifies the sector where programmable card number
(PCN) is stored if the Sector type (see above) is configured as
MAD. Default value: 5156 (Roger AID).
Block ID
The parameter specifies the block number where programmable
card number (PCN) is stored in a particular sector of card’s
memory. For sectors 0-31, blocks 0-2 are available while for
sectors 32-39, blocks 0-14 are available. Default value: 0.
Key type
The parameter specifies key type used for encryption of data in
card’s memory. Default value: A.
Key
The parameter specifies 6-byte key used to encrypt data in card’s
RWL-2 Operating Manual.doc
2018-06-29
14/17
memory. Default value: FF...FF.
Mifare UltraLight settings
Sector type
When the parameter is enabled then returned card number (RCN)
is composed of two parts: the programmable card number (PCN)
and the card serial number (CSN).
When the option is disabled then the returned card number (RCN)
is composed of the card serial number (CSN) only.
Default value: None.
SSN first page number
The parameter specifies memory page where the programmable
card number (PCN) is stored. Default value: 0.
Mifare Plus settings
Sector type
When the parameter is enabled then returned card number (RCN)
is composed of two parts: the programmable card number (PCN)
and the card serial number (CSN).
When the option is disabled then the returned card number (RCN)
is composed of the card serial number (CSN) only.
Default value: None.
Format
The format of the programmable card number (PCN) stored in the
card’s memory. Default value: BIN.
First byte position (FBP)
The parameter specifies the position of the most significant byte
(MSB) of programmable card number (PCN). Default value: 0.
Last byte position (LBP)
The parameter specifies the position of the least significant byte
(LSB) of programmable card number (PCN). Default value: 7.
Sector ID
The parameter specifies sector number in card’s memory where
programmable card number (PCN) is stored. Default value: 0.
Application ID
The parameter Application ID (AID) is located in card’s MAD sector
and it specifies the sector where programmable card number
(PCN) is stored if the Sector type (see above) is configured as
MAD. Default value: 5156 (Roger AID).
Block ID
The parameter specifies the block number where programmable
card number (PCN) is stored in a particular sector of card’s
memory. For sectors 0-31, blocks 0-2 are available while for
sectors 32-39, blocks 0-14 are available. Default value: 0.
Key type
The parameter specifies key type used for encryption of data in
card’s memory. Default value: A.
Key
The parameter specifies 16-byte key used to encrypt data in card’s
memory. Default value: FF...FF.
Mifare DesFire settings
Sector type
When the parameter is enabled then returned card number (RCN)
is composed of two parts: the programmable card number (PCN)
and the card serial number (CSN).
When the option is disabled then the returned card number (RCN)
is composed of the card serial number (CSN) only.
Default value: None.
Format
The format of the programmable card number (PCN) stored in the
card’s memory. Default value: BIN.
First byte position (FBP)
The parameter specifies the position of the most significant byte
RWL-2 Operating Manual.doc
2018-06-29
15/17
(MSB) of programmable card number (PCN). Default value: 0.
Last byte position (LBP)
The parameter specifies the position of the least significant byte
(LSB) of programmable card number (PCN). Default value: 7.
Sector ID
The parameter specifies sector number in card’s memory where
programmable card number (PCN) is stored. Default value: 0.
File ID (FID)
The parameter specifies file identifier for AID application: 0-16 for
MF DESFire EV0, 0-32 for MF DESFire EV1. Default value: 0.
Communication protection
level
The parameter specifies encryption type for communication
between card and reader. Default value: Plain.
Key number
The parameter specifies the number of key used to access data in
card’s memory. Default value: 0.
Key type
The parameter specifies key type used for encryption of data in
card’s memory. Default value: TDES Native.
Key
The parameter specifies key used to encrypt data in card’s
memory. For 3KTDES a 24-byte key required while for remaining
TDES and AES keys a 16-byte key is required. Default value:
FF...FF.
Users
Credentials tab in RogerVDM top menu enables management of the cards programmed in the lock’s
memory. As explained earlier, lock can operate with 50 users with Main card and Backup card or 100
users with Main card only. Each user can be granted with Normal access and/or Office mode
authorisation. If programmed, the Backup card have the same authorisations as a Main card it
accompanies. When user is granted with the Normal access authorisation it can open a door for the
time defined by Lock pulse parameter. When user is granted with Office mode it can open the door for
unlimited time and then, when required using the same card it can terminate Office mode. Both
options can be granted to the same user.
When card has both authorisations, with the first card usage lock opens for Lock pulse time and waits
for optional second card usage what is signalled by LED SYSTEM blinking. If the card is used second
time lock switches into Office mode. If the lock is in the Office mode then with the single use of a card
with Office mode authorisation lock terminates Office mode.
Note: When wireless communication is lost the lock switches automatically from Online mode to
Offline mode. It returns to Online mode as soon as the radio link is returned.
Memory reset
Memory reset erases all programmed card and restores factory configuration settings. After reset the
locks operates in Offline mode with 50 users list and reads card serial number (CSN). In order to
perform memory reset procedure proceed with following steps:
• Remove jumper from the MEM pins (if applicable).
• Short RST pins for a moment preferably by placing and removing jumper.
• When acoustic signalization is started place jumper on MEM pins and the devices shall
confirm memory reset with 3 acoustics beeps.
• Read any proximity card and it shall be new ADD programming card.
• Read any proximity card and it shall be new DEL programming card.
• Wait for 3 acoustic beeps. The lock shall restore default factory settings and shall switch to
normal operation.
RWL-2 Operating Manual.doc
2018-06-29
16/17
Note: If device will be used in Online Mode, additionally read the DEL card five times.
INSTALLATION
The lock is designed for installation in door with 38 to 75mm thickness and with 72mm handle
spacing. Prior to installation make sure that door cylinder is long enough.
Lock installation
• Make holes in door using drilling template. In case of non-rebated door it might be
necessary to use metal plate. Both, drilling template and metal plate are included in the
factory new set.
• Optionally install external door contact (e.g. reed relay) and deadbolt contact - connect
them to F group of wires (fig. 3).
• Lead battery wires through hole and then connect them to the external escutcheon.
• Check position of spindle support (fig. 7) and mount door handle spindle.
• Install batteries (4xAAA) in the pack and then insert into internal escutcheon.
• Mount escutcheons and verify if the internal handle controls the cylinder and metal key can
open the door.
Note: Ensure access to metal key to enable emergency opening of the door.
Wire's color
Description
Yellow
Deadbolt contact (mortise)
Green
Door contact
Brown
GND
Fig. 7 Proper position of spindle support
Specification
Parameter
Value
Power supply
4 x AAA (LR06) alkaline batteries
Battery life
Approx. 1 years with 10 entries per day
Door thickness
38 – 75 mm
Handle spacing
72 mm
Wireless communication
According to IEEE 802.15.4/ 2.4GHz standard; transmission range
up to 10m
RWL-2 Operating Manual.doc
2018-06-29
17/17
Built-in card reader
ISO/IEC 14443A MIFARE® Ultralight, Classic, DESFire EV1, Plus
Environmental class
(acc. to EN 50131-1)
Class I, indoor general conditions, temperature: +5°C to +40°C,
relative humidity: 10 to 95% (no condensation)
IP code
IP40
Dimensions
47 x 280mm
Weight
Approx. 1100g
Certificates
CE (see: INSTALLATION section)
Ordering information
Product
Description
RWH-1
RACS 5 AIR wireless hub
RWL-2-L
Wireless door lock with escutcheons; left hand, left hand reverse
RWL-2-R
Wireless door lock with escutcheons; right hand, right hand reverse
Product history
Product version
Released
Description
1.0
IX 2017
The first commercial version of the product
This symbol placed on a product or packaging indicates that the product
should not be disposed of with other wastes as this may have a negative
impact on the environment and health. The user is obliged to deliver
equipment to the designated collection points of electric and electronic
waste. For detailed information on recycling, contact your local authorities,
waste disposal company or point of purchase. Separate collection and
recycling of this type of waste contributes to the protection of the natural
resources and is safe to health and the environment. Weight of the
equipment is specified in the document.
Contact:
Roger sp. z o.o. sp.k.
82-400 Sztum
Gościszewo 59
Tel.: +48 55 272 0132
Fax: +48 55 272 0133
Tech. support: +48 55 267 0126
E-mail: [email protected]
Web: www.roger.pl