Roger PR311 Installation And Programming Manual
| Brand: | Roger |
| Category: | IP Access Controllers |
| Model: | PR311 (Installation And Programming Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 32 |
Text of Roger PR311 Installation And Programming Manual
Roger PR311 PR311 v1.0 fv102 EN Rev.E.DOC
10/22/2007
2
1 T A B L E O F C O N T E N T S
1
Table of Contents
2
2
Glossary and Terms
3
3
Introduction
5
3.1
Designed Function
5
3.2
Main Features
5
3.3
Operation in the Integrated Access System
5
3.4
Stand-alone Operation
6
4
Functional Description
6
4.1
Users
6
4.2
Group of Users
6
4.3
User Identification
6
4.4
ARMED and DISARMED Modes
7
4.5
Arming and Disarming of the Controller (Rearming)
7
4.6
Unlocking a Door
8
4.7
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
3
2 G L O S S A R Y A N D T E R M S
Identifier
The method or means which is used to identify a person. It can be a proximity car, a PIN code, a finger
template etc. In some cases Identifier may consist of two or more of item required for a single identification
procedure. For example when the option [Card and PIN] is active then Identifier=Card+PIN.
Stand-alone Mode
The situation when device operate without physi
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
4
XM-2 I/O Extension Module
The external I/O extension module which can be connected to PR311 controller via Clock & Data lines.
PRT Series Readers
The family of PRT reader’s family developed and manufactured by Roger. Each member of PRT series readers
can be connected to PR311 access controller via Clock & Data interface. Typically the remote reader is used for
two-way door control.
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
5
3 I N T R O D U C T I O N
3.1
Designed Function
The PR311 access controller has been designed for use in access control installations or systems as an outdoor
access control device to enable user identification via EM 125 kHz UNIQUE standard proximity cards and/or
PINs. The PR311 unit can operate stand-alone or as a part of integrated (networked) access control system.
When controller operate as a stand-alone uni
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
6
3.4
Stand-alone Operation
In this case the PR311 access controller autonomously supervises door passage and doesn’t require any
connection to the Host device. All users belong to the same group which has permanent access authorization
regardless of time. Neither the Identification Mode nor Door Mode can be controlled by time schedules, events
are not registered.
4 F U N C T I O N A L D E S C R I P T I O N
4.1
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
7
4.4
ARMED and DISARMED Modes
The PR311 has two working operating modes: Armed and Disarmed mode. The actual controller’s operating
mode is indicated on the dual color LED STATUS, which lights in red for Armed or green for Disarmed. Generally
the Armed and Disarmed modes are dedicated for integration of the controller with the alarm system which
protects the same room or area which is supervised by the access con
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
8
Note: If programmed the condition on the input line configured to function no. 13 can disable arming of a
controller.
4.6
Unlocking a Door
In order to unlock the door a user is obliged to enter his identifier. Whenever this happens the device activates
LED SYSTEM (orange) for a moment and generates a short confirmation beep. If the entered identifier has
authorization for entry controller energizes the door lock f
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
9
Flags are logical registers which exist in controller’s memory. Each Flag represent a status of relevant situation
which may occur on controller. For example if a user enters a DURESS PIN code this will activate (sets ON) the
DURESS flag, when controller recognizes triggering of the TAMPER input it will trigger (sets ON) the TAMPER
flag etc.
The PR311 utilizes the following flags:
AUX1 Flag
LIGHT Flag
�
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
10
Note: Forced Entry and Door Ajar alarms will occur only if the reader operates with a Door Open Contact.
4.16 Inputs
The PR311 provides five logical inputs, three inputs are physically located on the PR311 itself and two on the
remote XM-2 I/O extension module. Each input can be configured as NO or NC type and may have assigned
function from a list below:
Table 4: Input line functions
Function
Code
Description
In
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
11
used to indicate a loss of AC power supply. Each time this input is
triggered it activates the TROUBLE flag timer which can further
activate (if programmed) the TROUBLE output (code 70).
Low Battery
06
Input is dedicated for connection to an output line or a contact which is
used to indicate a loss of AC power supply. Each time this input is
triggered it activates the TROUBLE flag timer which can further
activate
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007
12
4.17 Outputs
The PR311 provides five logical outputs. Three of them (called OUT1, OUT2 and OUT3) are located on the
controller’s electronic module while two others are located on the optional XM-2 extension module. Each output
can be configured to one of the following output functions:
Table 5: Output lines functions
Function
Code
Description
Disarmed Mode
00
The output line switches to ON and remains so for as
Roger IP Access Controllers Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
MCT86M-IO-CH-HR |
MCT86M-IO-CH-HR Installation manual - 68DYHU |
2 | 1192 | 275 | 04-10-2026 | |
MCT88M-IO |
User Manual: Roger MCT88M-IO (87LD5P, Upd.18-08-2026) |
2 | 528 | 90 | 18-08-2026 | |
PR201 |
PR201 Installation and programming manual - 1S7162 |
19 | 1200 | 276 | 25-08-2026 | |
PR402DR-BRD |
Roger IP Access Controllers Installation manual (File: PDF, 15-08-2026) |
2 | 1127 | 226 | 15-08-2026 | |
F7 |
IP Access Controllers #869UA3 |
24 | 712 | 107 | 08-07-2026 | |
PR411DR-SET |
PR411DR-SET (IP Access Controllers ePDF User Manual, #K79KP6) |
2 | 404 | 85 | 03-06-2026 |