Roger PR311 Installation And Programming Manual

Brand: Roger
Category: IP Access Controllers
Model: PR311 (Installation And Programming Manual)
File Type: PDF
File Size: —
Pages: 32
Text of Roger PR311 Installation And Programming Manual

Roger PR311 PR311 v1.0 fv102 EN Rev.E.DOC

10/22/2007 2 1 T A B L E O F C O N T E N T S 1 Table of Contents 2 2 Glossary and Terms 3 3 Introduction 5 3.1 Designed Function 5 3.2 Main Features 5 3.3 Operation in the Integrated Access System 5 3.4 Stand-alone Operation 6 4 Functional Description 6 4.1 Users 6 4.2 Group of Users 6 4.3 User Identification 6 4.4 ARMED and DISARMED Modes 7 4.5 Arming and Disarming of the Controller (Rearming) 7 4.6 Unlocking a Door 8 4.7
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007 3 2 G L O S S A R Y A N D T E R M S Identifier The method or means which is used to identify a person. It can be a proximity car, a PIN code, a finger template etc. In some cases Identifier may consist of two or more of item required for a single identification procedure. For example when the option [Card and PIN] is active then Identifier=Card+PIN. Stand-alone Mode The situation when device operate without physi
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007 4 XM-2 I/O Extension Module The external I/O extension module which can be connected to PR311 controller via Clock & Data lines. PRT Series Readers The family of PRT reader’s family developed and manufactured by Roger. Each member of PRT series readers can be connected to PR311 access controller via Clock & Data interface. Typically the remote reader is used for two-way door control.
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007 5 3 I N T R O D U C T I O N 3.1 Designed Function The PR311 access controller has been designed for use in access control installations or systems as an outdoor access control device to enable user identification via EM 125 kHz UNIQUE standard proximity cards and/or PINs. The PR311 unit can operate stand-alone or as a part of integrated (networked) access control system. When controller operate as a stand-alone uni
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007 6 3.4 Stand-alone Operation In this case the PR311 access controller autonomously supervises door passage and doesn’t require any connection to the Host device. All users belong to the same group which has permanent access authorization regardless of time. Neither the Identification Mode nor Door Mode can be controlled by time schedules, events are not registered. 4 F U N C T I O N A L D E S C R I P T I O N 4.1
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007 7 4.4 ARMED and DISARMED Modes The PR311 has two working operating modes: Armed and Disarmed mode. The actual controller’s operating mode is indicated on the dual color LED STATUS, which lights in red for Armed or green for Disarmed. Generally the Armed and Disarmed modes are dedicated for integration of the controller with the alarm system which protects the same room or area which is supervised by the access con
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007 8 Note: If programmed the condition on the input line configured to function no. 13 can disable arming of a controller. 4.6 Unlocking a Door In order to unlock the door a user is obliged to enter his identifier. Whenever this happens the device activates LED SYSTEM (orange) for a moment and generates a short confirmation beep. If the entered identifier has authorization for entry controller energizes the door lock f
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007 9 Flags are logical registers which exist in controller’s memory. Each Flag represent a status of relevant situation which may occur on controller. For example if a user enters a DURESS PIN code this will activate (sets ON) the DURESS flag, when controller recognizes triggering of the TAMPER input it will trigger (sets ON) the TAMPER flag etc. The PR311 utilizes the following flags:  AUX1 Flag  LIGHT Flag �
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007 10 Note: Forced Entry and Door Ajar alarms will occur only if the reader operates with a Door Open Contact. 4.16 Inputs The PR311 provides five logical inputs, three inputs are physically located on the PR311 itself and two on the remote XM-2 I/O extension module. Each input can be configured as NO or NC type and may have assigned function from a list below: Table 4: Input line functions Function Code Description In
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007 11 used to indicate a loss of AC power supply. Each time this input is triggered it activates the TROUBLE flag timer which can further activate (if programmed) the TROUBLE output (code 70). Low Battery 06 Input is dedicated for connection to an output line or a contact which is used to indicate a loss of AC power supply. Each time this input is triggered it activates the TROUBLE flag timer which can further activate
PR311 v1.0 fv102 EN Rev.E.DOC 10/22/2007 12 4.17 Outputs The PR311 provides five logical outputs. Three of them (called OUT1, OUT2 and OUT3) are located on the controller’s electronic module while two others are located on the optional XM-2 extension module. Each output can be configured to one of the following output functions: Table 5: Output lines functions Function Code Description Disarmed Mode 00 The output line switches to ON and remains so for as

Roger IP Access Controllers Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
MCT86M-IO-CH-HR

MCT86M-IO-CH-HR Installation manual - 68DYHU

2 1192 275 04-10-2026
MCT88M-IO

User Manual: Roger MCT88M-IO (87LD5P, Upd.18-08-2026)

2 528 90 18-08-2026
PR201

PR201 Installation and programming manual - 1S7162

19 1200 276 25-08-2026
PR402DR-BRD

Roger IP Access Controllers Installation manual (File: PDF, 15-08-2026)

2 1127 226 15-08-2026
F7

IP Access Controllers #869UA3

24 712 107 08-07-2026
PR411DR-SET

PR411DR-SET (IP Access Controllers ePDF User Manual, #K79KP6)

2 404 85 03-06-2026

IP Access Controllers: Similar Manuals