U N I Q U E E L I T E 3 0 E & 3 6 E

13 To reduce the risk of tipping the appliance by abnormal usage or improper door loading, the appliance must be secured by properly installing the anti-tip device packed with the appliance. To check if the device is installed and engaged properly, carefully tip the range forward. The anti-tip device should engage and prevent the range from tipping over. If this range is removed for any reason, (eg. service or cleaning), it must be replaced as outlined before placing the range back in operation. Levelling a Free-Standing Range All free-standing ranges must be level to obtain proper cooking results. The leveling legs should be screwed into the corner brackets. Place pan or measuring cup partially filled with water or a level on the oven rack. Adjust the leveling legs until the range is level. The top of the aside panels should be level with the counter top.

U N I Q U E E L I T E 3 0 E & 3 6 E

14 GAS CONNECTIONS (All Units) NOTICE TO MASSACHUSETTS APPLIANCE DEALERS: Be sure this document is included in all gas range appliances sold to consumers in the State of Massachusetts. NOTICE: Massachusetts law requires the following: � Appliances must be installed by a licensed plumber or gas fitter. � Appliances must be connected with a three (3) foot (36” maximum length) flexible gas connector and � A “T” handle type manual gas valve in the gas supply line to the appliance. � Have the dealer where you purchase your new range install it or have him recommend a qualified installer. Installation must conform with local codes. In the absence of local codes, the installation must conform with the National Fuel Gas Code, ANSI Z223.1-Latest Edition in the U.S.A. or the CAN/CGA B149.1 or .2 Installation Codes in Canada. The range should be connected to the supply line with 1/2-inch black iron pipe or a certified flexible type range connector. To prevent gas leaks, put an approved sealing compound, which is resistant to liquefied petroleum gases, on all threaded connections. Important: Do not apply pressure directly to the range manifold pipe when tightening supply connections. The manifold pipe should be held securely at the pressure regulator to prevent twisting. Hold the pressure regulator with a wrench during the tightening of the connection, or the manifold pipe may be twisted and split, and cause a dangerous leak. The installation of ranges designed for manufactured (mobile) home installation must conform with the Manufactured Construction and Safety, Title 24 CFR, Part 3280, [formerly the Federal standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] in the U.S.A. or C.S.A. Standard CAN/CGA Z240.4.2 in Canada or, when such standards are not applicable with local codes. The installation of ranges designed for recreational vehicle installation must conform to state or other codes and in the absence of such codes with the standard for recreational vehicles ANSI A119.2.2–1982 in the U.S.A. or CAN/CGA Z240.4.2 in Canada. The installation of appliances designed for recreational park trailers must conform to recreational park trailers, ANSI A119.5. Note: Check all piping connections in the unit for leaks. Never use an open flame to check for gas leaks using a soap solution with at recommend ratio of 75% water, 25% dish washing soap. It’s possible for connections made at the factory to leak, due to vibration encountered in transportation. Make certain you have checked them all, and repair any connections that leak.

U N I Q U E E L I T E 3 0 E & 3 6 E

15 The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psig. The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. Installation It is the responsibility of the installer to make certain that the range is properly adjusted at the time of installation. Situations caused by improper adjustments or improper installation are not covered under the warranty. Any expenses incurred due to such situations will not be paid by the manufacturer of the appliance. Connecting gas to range This range is designed to operate at a pressure of 4” of water column on natural gas (NG) or 10” of water column on propane gas (LPG). Make sure you are supplying your range with the type of gas for which it is designed. This range comes equipped from the factory equipped for use with LPG (propane). This range is convertible for use on natural gas (NG) also. (Natural gas � Gas line shut-off valve � To reduce the possibility of gas leaks, apply Teflon tape or a thread compound approved for use with LP or Natural gases to all threaded connections. � Connect a ½” threaded pipe to the units regulator located at the back right of the unit. We suggest using a ½” female to 3/8” male flare adaptor on the end of the ½” threaded pipe. � Use a flexible appliance connector to connect your gas supply to the appliance. A 3 foot length is recommended for ease of installation but other lengths are acceptable. Never use an old connector when installing a new range. � Check for leaks using a leak detector or soapy water with a recommended ratio of 75% water, 25% dish washing soap

U N I Q U E E L I T E 3 0 E & 3 6 E

16 orifices included in the packaging). When using this on NG gas, conversion must be made by a qualified NG installer before attempting to operate the range on that gas For correct operation, the pressure of natural gas supplied to the regulator should be between 4” and 5” of water column. For LP gas, the pressure supplied must be between 10” and 12” of water column. When checking for correct operation of the regulator, the inlet pressure must be at least 1” more than the operating -manifold- pressure as given above. The pressure regulator located at the back of the range manifold must remain in the supply line regardless of whether natural or LP gas is being used. Regulator is only good for ½ psi (14” w.c.) so test pressure must not exceed ½” psi. Shut off the main gas supply valve before removing the old range and leave it off until the new hook-up has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on. Because hard piping restricts movement of the range, the use of a CSA certified flexible metal appliance connector is recommended unless local codes require a hard- piped connection. Never reuse an old connector when installing a new range. If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made. To prevent gas leaks, use pipe joint compound resistant to LP or NG gases (depending on set up) on all male -external- pipe threads. 1. In an easily accessible location, install a service manual gas shut off valve. Be sure everyone operating the range knows where and how to shut off the gas supply to the range. 2. When all connections have been made, be sure all range controls are in the off position and turn on the main gas supply valve. Check for gas leaks by using a soap and water solution. If a gas leak is present, shut off gas immediately, tighten all connections, and retest for leaks. � 3. Any opening in the wall behind the appliance and in the floor under the appliance shall be sealed.

U N I Q U E E L I T E 3 0 E & 3 6 E

17 After installation: 1. Check ignition of cooktop burners. 2. Check ignition of oven burner. 3. Check ignition of broil burner 4. Check ignition of griddle burner (36E model only) 5. Check for gas leaks at all gas connections (using a gas detector, never a flame).