UNI-T UT501 Operation & User’s Manual
Read Online
Read the UNI-T UT501 Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
RS-422/RS-485 Photoelectric Isolation
Data Repeater
User’s Manual
I、General introduction:
U T 5 0 1 - data repeater is a kind of data relay
communication product of photoelectric isolated
RS-422/RS-485. It can be used with ATC-108
Photoelectric
Isolation
Interface
Converter
in
combination. UT-501 data repeater can prolong the
communication distance of RS-422/RS-485 bus
network and increase the number of RS-422/RS-485
bus network devices. The inner circuit of ATC-109N
Photoelectric Isolation Data Repeater can detect data
direction and switch to control it automatically,
conveniently to form a RS-485 network without any
shake hand signal. This kind of RS-485 control is
fully transparent and need not amend software for the
former network basing on RS-422/485 working
modes. The built in photoelectric isolator and DC/DC
converter can offer 3500V isolation voltage and the
rapid Transient Voltage Suppressor (TVS) can
effectively inhibit lightning and ESD, provide 1000W
lightning strike and surge protection power on each
line, and prevent lightning strike and common code
interference.
II、Performance parameter
1. Interface feature: interface is compatible with
EIA/TIA RS-485/RS-422 standard
2. Electric interface: RS-422/RS-485 interfaces are
DB9 interfaces
3. Transmission media: twisted-pair cable or shielded
cable
4. Working mode: asynchronous half or full duplex
5. Signal indication: 3 signal indication lights indicate
TXD, RXD and PWR
6. Isolation: isolation voltage 3500VRMS 500VDC
sequence
7. Transmission speed: 115.2K BPS to 1.2KM
38.4K BPS to 2.4KM
9600 BPS to 5KM
8. Protecting grade: RS-422, RS-485 interface 1000W
lightning strike and surge protection on each line
9. Extended distance: 0-5 kilometers
(115200-9600BPS)
10. Size: 125mmx54mmx25mm
11. Working environment: -25℃ to 70℃, 5% to
95% relative humidity
III. Circuit function block diagram:
IV.Connector and signal
RS-422/485 Pinout: (6-bit terminal from the left to right))
Terminal
No
1
2
3
4
5
6
RS-422
T+
T-
R+
R-
VIN
GND
RS-485
485+
485-
-
-
VIN
GND
V. Installation setup and application:
Please read the User’s Manual carefully before
installing U T - 5 0 1 Photoelectric Isolation Data
Repeater. Connect the product’s power converter with
+9V socket. The Termnal pin shall be connected with
RS-422 or RS-485 network equipments according to
definition instruction.
U T - 5 0 1 Photoelectric Isolation Data Repeater
supports following 3 relay communication modes:
1. RS-422/ 4 wire full duplex relay
2. RS-485/ dual-line half duplex
3. 4 wire RS-485 to 2 wire RS-485 relay
RS-422 to RS-422 relay: .
RS-485 to RS-485 relay:
4 wire RS-485 to 2 wire RS-485 relay:
VI. Sketch map for communication connection
1. RS-422 4 wire full duplex data relay
2. RS-485 dual-line half duplex data relay
3. 4- Wire RS-485 to 2-Wire RS-485 data relay
VII. Power and surge grounding protection
1. External power supply:
UT-501 Photoelectric Isolation Data Repeater can
adopt the product’s DC9V power adapter for power
supply or adopt power from other DC power or device.
The power supply voltage is +9---+12V, current
100mA.The connection pins are Terminal :V+,V-
2. Surge grounding protection:
Common repeater has no large energy protector.
The transient high voltage induced in interface data
line tries to release energy to the ground wire via
the minimum resistance route of the device and
thus can easily cause damage to interface parts.
ATC-109N Photoelectric Isolation Data Repeater
can provide 1000W lightning strike and surge
protection power on each line. The rapid Transient
Voltage Suppressor (TVS) can effectively inhibit
lightning and ESD. ATC-109N Photoelectric
Isolation Data Repeater terminal Pin FGND is
designed for surge grounding protection. The user
shall try to avoid hanging by credible grounding to
ensure the safety of communication during
operation
VIII. Trouble shooting
1. Data transmission failure:
A. check to make sure the RS-422 interface is
correctly connected
B. check to make sure the RS-485 interface is
correctly connected
C. check to make sure the power supply voltage
and polarity are correct.
2. Data loss or error:
A. Check the consistency of the data speeds and
formats at the both ends of the data communication
device.