Texecom Premier Elite CO-W Instruction Manual

Specifications

Brand: Texecom
Category: Security Sensors
Model: Premier Elite CO-W
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Texecom Premier Elite CO-W Instruction Manual online using the built-in PDF viewer.

Text of the manual

Premier Elite CO-W

Carbon monoxide detector with Ricochet mesh technology MADE IN ENGLAND INS672-2 4. Mounting location when connecting to alarm system Metal Lintel 230V 110V >1m >1m Metal Filing Cabinet >1m 6. Installing the detector - wall-mounting NOTE: THIS ALARM MUST BE INSTALLED BY A COMPETENT PERSON AND IS TO BE INSTALLED ACCORDING TO THESE INSTRUCTIONS 1. Drill two holes in a wall 9cm apart (you may wish to use the backplate for guidance). 2. Insert the two rawl-plugs, that are supplied, into the holes. 3. Insert the two screws as supplied into the holes ensuring enough of the screw s ticks out of the wall (approx. 8mm). 4. Hook the rear over the screws (as shown below). 5. Tighten screws. 6. Hook in and clip on the front of the detector. 7. Tighten screw. 1. What is carbon monoxide? Carbon monoxide (CO) is a highly poisonous gas that has no taste, colour or smell. Potential Sources of CO • Wood-burning stoves • Gas boilers and fires • Gas Hobs • Oil and coal burning appliances • Portable gas heaters • Blocked flues and chimneys • Fumes from integral garages • Barbecues This CO alarm is no substitute for proper maintenance of your appliances. Carbon monoxide can be produced from poorly burning appliances or from blocked flues and chimneys. If your alarm has sounded and you have ventilated the room the CO may have dispersed before help arrives. It is crucial that the source of CO is determined and appropriate maintenance carried out. Carbon monoxide is a cumulati ve poison meaning long-term exposure to low levels may cause symptoms. The Premier Elite CO-W is time-weighted - the higher the level of CO, the sooner it will alarm. 2. Alarm levels as defined by EN50291-2010 The table below shows the response times at which the Premier Elite CO-W alarm will sound; Alarm response times (as prescribed by EN 50291-1): CO Concentration Alarm Delay 50 ppm 60 - 90 minutes 100 ppm 10 - 40 minutes 300 ppm Less than 3 minutes CO advice and information The table below shows the effects of different levels of CO poisoning on the body; Parts per million Affects on adults 100 ppm Slight headache, nausea, fati gue 200 ppm Dizziness and headache within 2-3 hours 400 ppm Nausea, frontal headache, drowsiness, confusion and rapid heart rate. Risk to life after over 3 hours of exposure 800 ppm Severe headaches, convulsions, vital organ failures. Death possible within 2-3 hours 5. Learning the device to the alarm system (optional) The CO-W operates either as a stand alone alarm or it can be connected to a Texecom Premier Elite wireless alarm system. Do not insert the batteries until you are ready to learn the device to the system. Battery connection will automatically start the learning sequence. Device reverts back to programmed network if receiver is not in learn mode (when replacing battery). For wireless connectivity, detailed programming and system set-up instructions please refer to the compatible Ricochet technology enabled Premier Elite wireless expander/wireless control panel instructions. The Premier Elite CO-W is only compatible with Premier Elite control panels V3.01.02 and above. The CO-W has a tamper detection facility that will report to the Texecom alarm panel when the product has been opened. 3. Mounting locations Recommended locations Not recommended Install the alarm at a horizontal distance of between 1m and 3m from fuel burning appliances. Do not install next to a door, window, extractor fan or air vent. Away from draughts, such as doors and windows Do not wall-mount close to obstructi ons (e.g. behind curtains, shelving or furniture) Within hearing distance of bedrooms.* If a heati ng appliance is in the bedroom place the alarm at sleeping height Do not fit in dusty, dirty or greasy areas (e.g. garages or workshops) If wall-mounti ng, install at eye- level (approx 1.5m), and at least 30cm from adjoining walls or ceiling Do not wall-mount within 30cm of the ceiling as this is a “dead air” space If free-standing, the unit should be placed no more than 1 metre from the ground (to avoid permanent damage in case accidentally knocked) Avoid humid (bathrooms), cold (< 4°C) or hot (>40°C) areas and away from sinks *It is recommended that at least one Premier Elite CO-W carbon monoxide alarm is installed on each level of the home. 1 2 7. Installing the detector - free-standing NOTE: THIS ALARM MUST BE INSTALLED BY A COMPETENT PERSON AND IS TO BE INSTALLED ACCORDING TO THESE INSTRUCTIONS 1. Lift out the stand, on the back of the detector, from the bottom and click into place (as shown below). 2. Position the detector no more than 1 meter from the floor (to minimize the risk of the detector being permanently damaged should it be knocked to the floor from a greater height). 3. Make sure the detector is in the upright position and not lying flat on the surface. Opening the detector 1. Unscrew the screw on the underside of the detector. 2. Un-clip the front of the detector from the backplate. TOP

13. What to do in the event of an alarm

WARNING! Activation of the alarm indicates the presence of Carbon Monoxide (CO) which can kill you. If the alarm sounds (0.5 seconds on, 0.5 seconds off and flashing red light): • Keep calm and open the doors and windows to ventilate the property. • Stop using all fuel burning appliances and ensure, if possible, that they are turned off. • Evacuate the property leaving the doors and windows open. • Get medical help immediately for anyone suffering the effects of carbon monoxide poisoning (headache, nausea), and advise that carbon monoxide poisoning is suspected. • Ring your gas or other fuel supplier on their emergency number; keep the number in a prominent place. • Write your fuel supplier’s emergency number here (see below for more useful numbers): • Do not re-enter the property until the alarm has stopped. When exposed to fresh air it can take up to 10 minutes for the sensor to clear and the alarm to stop depending on the level of carbon monoxide detected. • Do not use the appliances again until they have been checked by an expert. In the case of gas appliances the engineer must be registered. The Premier CO-W is protected by UK & International Registered Designs. Premier Elite is a Trademark of Texecom Ltd. © 2015 Texecom Ltd. www.texe.com INS672-2 FM 35285 Regulatory information Supplier: Texecom Ltd, St. Crispin Way, Haslingden, Lancashire, BB4 4PW, UK. Weee Directive: 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. Maintenance: Test yearly by the installer Warranty: 2 year replacement warranty (excludes battery) Standards Alarm Systems: EN50131-5-3, EN50131-1 EMC: EN50130-4: ETSI EN301 R&TTE: ETSI EN300-220 Environmental: EN50130-5 Class II Frequency Band: 868.2 to 868.6 Mhz Receiver: Category 1, Class 2 Receiver LBT (Listen Before Talk) Yes Transmitter Duty Cycle 868MHz<1% Low Battery Signal 2.4V Operating Voltage 3V Specifications Supervisory Interval 15 minutes Max current 100 mA Alarm Current 70 mA Supervisory Current 60 uA Battery Life 4 years Sensor Life: 10 years from date of installation. Batteries: 2 x 1.5V Alkaline batteries (Duracell Plus Power MN1500) Alarm Sound Level: > 85 dB(A) at 1m Operating temp. -5˚C to 55˚C Relative humidity 10 - 90% Non-condensing Dimensions 111mm(W) x 72mm(H) x 31mm(D) Weight (Inc Batteries) 150 g Warranty 2 years (excluding batteries) TYPE No. GBYA1000 11. Test button sequence The test button should be pressed every week. The detector will emit short chirps for about 5 seconds, and the green light will flash every 10 seconds for 4 minutes. During this time the detector will be more sensitive to detection of CO gas and will alarm at a lower concentration level. The detector will also generate a fault signal (two tone chirp every minute) if a fault is identified on the sensor. Further activation of the test button is disabled until the four minutes have expired. 12. Alarm sequence On detecting an unsafe level of CO, the detector will sound 0.5s on, 0.5s off. The red light will flash once every two seconds. 14. Maintenance of your alarm • Test every week. • Vacuum regularly to remove dust. • Keep away from solvents or detergents and nappy buckets. • Avoid spraying air-freshener, hair-spray near the alarm. • Do not paint the alarm. If decorating or using adhesives close to the alarm, remove it temporarily. • Annually check the installation date to see if the it’s within sensor life (10 years). If not, replace the unit. The following substances can affect the sensor and cause false alarms: Methane, Propane, Iso-butane, Iso-propanol, Ethylene, Benzene, Toluene, Ethyl acetate, Hydrogen Sulphide, Hydrogen, Sulphur Dioxide, alcohol based products, paints, thinners, solvents, adhesives, hair-sprays, aftershaves or perfumes and some cleaning agents. 15. Warnings & important notices WARNING: THIS CARBON MONOXIDE ALARM IS NOT A SUBSTITUTE FOR INSTALLING AND MAINTAINING AN APPROPRIATE NUMBER OF SMOKE ALARMS IN YOUR HOME. THIS ALARM WILL NOT SENSE SMOKE, FIRE, OR ANY POISONOUS GAS OTHER THAN CARBON MONOXIDE. FOR THIS REASON YOU MUST INSTALL SMOKE ALARMS TO PROVIDE EARLY WARNING OF FIRE AND TO PROTECT YOU AND YOUR FAMILY FROM FIRE AND ITS RELATED HAZARDS. WARNING: THIS PRODUCT IS INTENDED FOR USE IN ORDINARY INDOOR RESIDENTIAL AREAS. IT IS NOT DESIGNED TO MEASURE COMPLIANCE WITH COMMERCIAL AND INDUSTRIAL STANDARDS. THIS ALARM IS NOT SUITABLE FOR INSTALLATION IN HAZARDOUS LOCATIONS . INDIVIDUALS WITH MEDICAL PROBLEMS MAY CONSIDER USING WARNING DEVICES WHICH PROVIDE AUDIBLE AND VISUAL SIGNALS FOR CARBON MONOXIDE CONCENTRATIONS UNDER 30 PPM. IMPORTANT: THIS CARBON MONOXIDE ALARM IS DESIGNED TO DETECT CARBON MONOXIDE FROM ANY SOURCE OF COMBUSTION INCLUDING IMPROPER OR MALFUNCTIONING APPLIANCES. THE INSTALLATION OF THIS DEVICE SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER INSTALLATION, USE AND MAINTENANCE OF FUEL BURNING APPLIANCES INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS. WARNING: THIS ALARM WILL NOT WORK WITHOUT POWER. THIS ALARM REQUIRES A CONTINUOUS SUPPLY OF POWER. IMPORTANT: IF ANY FAULT SIGNALS OCCUR, CONTACT THE MANUFACTURER OR SUPPLIER AND DO NOT CONTINUE USING THE ALARM. The Premier CO-W detector has been tested as compliant with EN50291-1 and certified by Intertek. Test button Alarm (red LED) Power (green LED) 8. Battery installation/replacement Remove the batteries from the pack and insert them into the battery compartment. Make sure that you fit the batteries in accordance with the polarity markings (+ or -) within the battery compartment. 9. Start-up sequence The green light flashes every 2 seconds for the first minute. During this time the detector will perform a self-test. After this, the detector is working normally and the green light will flash every minute to indicate it has power. DO NOT PUSH THE TEST BUTTON DURING THIS FIRST MINUTE. 10. Low battery/fault sequence The detector will emit a two-tone chirp every minute if the battery needs replacing or a fault has been detected within the unit. The detector is fully able to determine that it is working correctly. If, after fitting new batteries, the two-tone chirp continues then replace the National Gas Emergency Service: 0800 111 999 (24 Hours) Gas Safe Register: 0800 408 5500 Add installation date WARNING: TAMPERING OR MODIFYING THIS DEVICE MAY RESULT IN THE PRODUCT MALFUNCTIONING AND NOT DETECTING CO GAS WARNING: THE PRODUCT MAY NOT PREVENT THE CHRONIC EFFECTS OF CARBON MONOXIDE EXPOSURE AND THE APPARATUS WILL NOT FULLY SAFEGUARD INDIVIDUALS IDENTIFIED AT SPECIAL RISK