Panasonic CS-E9PB4EA Operating Instructions Manual
Text of the manual
* Kindly consult authorised dealer for
connectivity validity.
Bedienungsanleitung
Klimagerät
10-17
* Wenden Sie sich bei Fragen zur
Gültigkeit der Konnektivität an Ihren
Fachhändler.
Handleiding
Airconditioner
18-25
* Wij verzoeken u vriendelijk een
geautoriseerde dealer advies te vragen
over de aansluitmogelijkheden.
Istruzioni di funzionamento
Condizionatore d’aria
26-33
* Si prega di consultare un rivenditore
autorizzato per la validità della
connettività.
Οδηγίες λειτουργίας
Κλιματιστικό
34-41
* Συμβουλευτείτε τον εξουσιοδοτημένο
αντιπρόσωπο για την καταλληλότητα
της σύνδεσης.
Comment utiliser l’appareil
Climatiseur
42-49
* Consultez un revendeur agréé pour
connaître la validité de la connectivité.
Instrucciones de funcionamiento
Climatizador de aire
50-57
* Consulte a un distribuidor autorizado
para conocer la validez de la
conectividad.
Instruções de funcionamento
Aparelho de ar condicionado
58-65
* Consulte o representante autorizado
para validar a conectividade.
Инструкции за работа
Климатик
66-73
* Моля, обърнете се към оторизиран
дилър относно валидността на
връзките.
Български
Português
Español
Français
Eλληνικά
Italiano
Nederlands
Deutsch
English
Model No.
Indoor Unit
Outdoor Unit
CS-E9PB4EA
CS-E12PB4EA
CU-E9PB4EA
CU-E12PB4EA
* Outdoor Unit
Multi Split
CU-2E15PBE
CU-2E18PBE
CU-3E18PBE
CU-4E23PBE
CU-4E27PBE
CU-5E34PBE
AMP Air Conditioning
www.ampair.co.uk | [email protected]
Thank you for purchasing Panasonic Air Conditioner.
Installation instructions attached.
Before operating the unit, read these operating instructions thoroughly and keep them for future
reference.
The illustrations in this manual are for explanation purposes only and may differ from the actual unit.
They are subject to change without notice for future improvement.
Multi air conditioner system
Multi air conditioner systems save space by
letting you connect multiple indoor units to a
single outdoor unit.
• For complete product features, please refer
catalogue.
Indoor units
• It is possible to operate the indoor units
individually or simultaneously. The priority
of operation is placed on the fi rst unit that
turned on.
• During operation, HEAT and COOL modes
cannot activate at the same time for
different indoor units.
• The power indicator blinks to indicate the
indoor unit is standing by for a different
operation mode.
Outdoor unit
Indoor units
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
CU-E9PB4EA, CU-E12PB4EA
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max.
32
23
43
26
Min.
16
11
-10
-
HEAT
Max.
30
-
24
18
Min.
16
-
-10
-
Multi split outdoor unit
CU-2E15PBE, CU-2E18PBE,
CU-3E18PBE, CU-4E23PBE,
CU-4E27PBE, CU-5E34PBE
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max.
32
23
46
26
Min.
16
11
-10
-
HEAT
Max.
30
-
24
18
Min.
16
-
-15
-16
AMP Air Conditioning
www.ampair.co.uk | [email protected]
Inserting the batteries
1 Pull out the back cover of
remote control
2 Insert AAA or R03 batteries
(can be used ~ 1 year)
3 Close the cover
TIMER
SET
CANCEL
ON
OFF
1
2
3
SET CHECK CLOCK
RESET
AC
RC
TIMER
CANCEL
ON
OFF
1
3
SET CHECK
RESET
AC
RC
2
3
1
Clock setting
1 Press CLOCK
2 Set the time
3 Confi rm
8m
MODE
POWERFUL/
QUIET
TEMP
OFF/ON
TIMER
SET
CANCEL
ON
OFF
1
2
3
FAN SPEED
SET CHECK CLOCK
RESET
AC
RC
FAN
SPEED
AIR
SWING
AIR SWING
AUTO
HEAT
COOL
DRY
POWERFUL/
QUIET
TIMER
SET
CANCEL
ON
OFF
1
2
3
FAN SPEED
SET CHECK CLOCK
RESET
AC
RC
FAN
SPEED
AIR
SWING
AIR SWING
AUTO
HEAT
COOL
DRY
1
2
3
Basic operation
1 Select the desired mode
DRY
AUTO
HEAT
COOL
2 Start/stop the operation
POWER
• Please note that the OFF
indication
is on to start.
3 Select the desired
temperature
• Selection range:
16 °C ~ 30 °C.
• Operating the unit within the
recommended temperature
may save energy.
HEAT : 20 °C ~ 24 °C.
COOL: 26 °C ~ 28 °C.
DRY : 1 °C ~ 2 °C
lower than room
temperature.
• To dim or restore the unit’s
indicator brightness, press
and hold for 5 seconds.
• Use remote control within 8 m
from the remote control receiver
of the indoor unit.
Table of contents
Safety precautions ...................4-5
How to use...............................6-7
Cleaning instructions ..................8
Troubleshooting ..........................9
Information................................74
Accessories
• Remote control
• AAA or R03 batteries × 2
• Remote control holder
• Screws for remote control
holder × 2
AMP Air Conditioning
www.ampair.co.uk | [email protected]
To prevent personal injury, injury to others or
property damage, please comply with the following:
Incorrect operation due to failure to follow
instructions below may cause harm or damage, the
seriousness of which is classifi ed as below:
WARNING
This sign warns of
death or serious injury.
CAUTION
This sign warns of
injury or damage to
property.
The instructions to be followed are classifi ed by the
following symbols:
This symbol denotes an action
that is PROHIBITED.
These symbols denote actions
COMPULSORY.
Air inlet
Air inlet
Air inlet
Air inlet
Air outlet
Air outlet
Air outlet
Air outlet
Indoor unit
Remote control
Power supply
Outdoor unit
WARNING
Indoor unit and outdoor unit
This appliance can be used by children aged from
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the
appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made
by children without supervision.
Please consult authorised dealer or specialist to
clean the internal parts, repair, install, remove and
reinstall the unit. Improper installation and handling
will cause leakage, electric shock or fi re.
Confi rm with authorised dealer or specialist on
usage of any specifi ed refrigerant type.
Using refrigerant type other than the specifi ed may
cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive or
fl ammable atmosphere. Failure to do so could result
in fi re.
Do not insert your fi ngers or other objects
into the air conditioner indoor or outdoor
unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it
may cause electric shock.
Do not expose yourself directly to cold air for a long
period to avoid excess cooling.
Do not sit or step on the unit, you may fall
down accidentally.
Remote control
Do not allow infants and small children to play with
the remote control to prevent them from accidentally
swallowing the batteries.
Power supply
Do not use a modifi ed cord,
joint cord, extension cord or
unspecifi ed cord to prevent
overheating and fi re.
AMP Air Conditioning
www.ampair.co.uk | [email protected]
To prevent overheating, fi re or electric shock:
• Do not share the same power outlet with other
equipment.
• Do not operate with wet hands.
• Do not over bend the power supply cord.
If the supply cord is damaged, it must be
replaced by the manufacturer, service agent or
similarly qualifi ed persons in order to avoid a
hazard.
It is strongly recommended to be installed
with Earth Leakage Circuit Breaker (ELCB)
or Residual Current Device (RCD) to prevent
electric shock or fi re.
Stop using the product if any abnormality/failure
occurs and disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/fi re/electric shock) Examples of
abnormality/failure
• The ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit is
observed.
• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it is
switched on for operation.
• The fan does not stop even if the operation is
stopped.
Contact your local dealer immediately for
maintenance/repair.
This equipment must be earthed to prevent
electrical shock or fi re.
Prevent electric shock by switching off the power
supply:
- Before cleaning or servicing,
- When extended non-use, or
- During abnormally strong lightning activity.
CAUTION
Indoor unit and outdoor unit
Do not wash the indoor unit with water, benzine,
thinner or scouring powder to avoid damage or
corrosion at the unit.
Do not use for preservation of precise equipment,
food, animals, plants, artwork or other objects.
This may cause quality deterioration, etc.
Do not use any combustible equipment in front of
the airfl ow outlet to avoid fi re propagation.
Do not expose plants or pet directly to airfl ow to
avoid injury, etc.
Do not touch the sharp aluminium fi n,
sharp parts may cause injury.
Do not switch ON the indoor unit when waxing
the fl oor. After waxing, aerate the room properly
before operating the unit.
Do not install the unit in oily and smoky areas to
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose to
avoid injury.
Do not step onto an unstable bench when
cleaning the unit to avoid injury.
Do not place a vase or water container on the
unit. Water may enter the unit and degrade the
insulation. This may cause an electric shock.
Do not open window or door for long time during
COOL/DRY mode operation.
Prevent water leakage by ensuring drainage
pipe is:
- Connected properly,
- Kept clear of gutters and containers, or
- Not immersed in water
After a long period of use or use with any
combustible equipment, aerate the room
regularly.
After a long period of use, make sure the
installation rack does not deteriorate to prevent
the unit from falling down.
Remote control
Do not use rechargeable (Ni-Cd) batteries. It may
damage the remote control.
To prevent malfunction or damage of the remote
control:
• Remove the batteries if the unit is not going to
be used for a long period of time.
• New batteries of the same type must be
inserted following the polarity stated.
AMP Air Conditioning
www.ampair.co.uk | [email protected]
How to use
Auto OFF/ON button
POWER (Green)
TIMER (Orange)
POWERFUL (Orange)
QUIET (Orange)
AUTO
AIR SWING (Orange)
Use when remote control is misplaced or a malfunction occurs.
1. Press the button once to use in AUTO mode.
2. Press and hold the button until you hear 1 beep, then release to use in forced
COOL mode.
3. Repeat step 2. Press and hold the button until you hear 2 beeps, then release
to use in normal COOL mode.
4. Repeat step 3. Press and hold the button until you hear 3 beeps, then release
to use in forced HEAT mode.
• Press the button again to turn off.
Control Panel
POWER (Green)
TIMER (Orange)
POWERFUL (Orange)
QUIET (Orange)
AUTO
AIR SWING (Orange)
OPEN
CLOSE
CLOSE
OPEN
POWER
TIMER
AIR SWING
OFF/ON
MODE
To select operation mode
AUTO - For your convenience
• During operation mode selection the POWER
indicator blinks.
• Unit selects operation mode every 10 minutes
according to setting temperature and room
temperature.
HEAT - To enjoy warm air
• Unit takes a while to warm up. The POWER
indicator blinks during this operation.
COOL - To enjoy cool air
• To reduce power consumption during COOL
mode, use curtains to screen off sunlight and
outdoor heat.
DRY - To dehumidify the environment
• Unit operates at low fan speed to give a gentle
cooling operation.
POWERFUL/
QUIET
To switch between
powerful & quiet
QUIET
POWERFUL
NORMAL
POWERFUL: To reach temperature quickly
POWERFUL
Single
• This operation stops automatically
after 20 minutes.
Multi
• Press the button again or turn OFF the
unit to stop this operation.
QUIET: To enjoy quiet operation
QUIET
• This operation reduces airfl ow noise.
Can be activated in all modes and can be
cancelled by pressing the respective button again.
Remote control
receiver
MODE
POWERFUL/
QUIET
TEMP
OFF/ON
TIMER
SET
CANCEL
ON
OFF
1
2
3
FAN SPEED
SET CHECK CLOCK
RESET
AC
RC
AIR SWING
FAN
SPEED
AIR
SWING
AUTO
HEAT
COOL
DRY
TEMP
OFF/ON
TIMER
SET
CANCEL
ON
OFF
1
2
3
CHECK CLOCK
Remote control
display
Press and hold for
approximately
10 seconds to show
temperature setting in
°C or °F.
Press to restore the
remote control to
default setting.
Not used in normal
operations.
Single Single split system
Multi
Multi split system
AMP Air Conditioning
www.ampair.co.uk | [email protected]
To select fan speed
(Remote control display)
• For AUTO, the indoor fan speed is automatically
adjusted according to the operation mode.
AIR SWING To adjust vertical airfl ow
direction
(Remote control display)
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver
swings up/down automatically.
• In HEAT mode, if AUTO is set, the horizontal
louver is fi xed at the predetermined position.
• Do not adjust the louver by hand.
How to use
To set the timer
2 sets of ON and OFF timers are available
to turn ON or OFF the unit at different preset
times.
TIMER
SET
CANCEL
ON
OFF
1
2
3
AC
C
CANCEL
3
AC
C
2
1
3
1 Select ON or OFF
timer
Example:
OFF at 22:00
• Each time pressed:
OFF
Cancel
2 Set the time
2
3 Confi rm
SET
TIMER
• To cancel ON or OFF timer, press
ON
or
OFF
to select respective
or
then press
CANCEL.
• If timer is cancelled manually or due to power
failure, you can restore the timer again by
pressing
ON or
OFF to select respective
or
then press
SET .
• The nearest timer setting will be displayed and
will activate in sequence.
• When ON Timer is set, the unit may start
earlier (up to 35 minutes) before the actual
set time in order to achieve the desired
temperature on time.
• Timer operation is based on the clock set in
the remote control and repeats daily once set.
For clock setting, please refer to Quick guide.
AMP Air Conditioning
www.ampair.co.uk | [email protected]
To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals.
Please consult authorised dealer.
• Switch off the power supply before cleaning.
• Do not touch the aluminium fi n, sharp parts may cause injury.
• Do not use benzine, thinner or scouring powder.
• Use only soap ( pH 7) or neutral household detergent.
• Do not use water hotter than 40 °C.
OPEN
CLOSE
CLOSE
OPEN
POWER
TIMER
AIR SWING
OFF/ON
2 Slowly pull
Slowly pull
down the
down the
intake grille.
intake grille.
3 Remove the air
Remove the air
fi lter from the
fi lter from the
tabs and pull it
tabs and pull it
downwards.
downwards.
1 Press the knobs.
Press the knobs.
Remove
Remove
CLOSE
OPEN
OPEN
CLOSE
Remove Air Filter
Knob
Insert the air
fi lter to the tabs
of the intake
grille.
Slowly bring
up the
intake grille.
Press the knobs to the
CLOSE side.
Air Filter Installation
1
2
3
INDOOR UNIT
Wipe the unit gently
with a soft, dry cloth.
AIR FILTER
Vacuum, wash and dry.
• lt is recommended to clean the air
fi lter every 6 weeks.
• Do not operate without an air fi lter.
• Wash/rinse the air fi lter gently with
water to avoid damage to the air fi lter
surface.
• Do not dry the part with a hair dryer
or a stove.
• Replace any damaged air fi lters.
For seasonal inspection after extended non-use
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• After 15 minutes of operation, it is normal to have the
following temperature difference between air inlet and
air outlet vents: COOL: ≥ 8 °C HEAT: ≥ 14 °C
For extended non-use
• Activate HEAT mode for 2~3 hours to
remove moisture left in the internal parts
thoroughly to prevent mould growth.
• Turn off the power supply.
• Remove the remote control batteries.
AMP Air Conditioning
www.ampair.co.uk | [email protected]
The following symptoms do not indicate malfunction.
Symptom
Cause
Mist emerges from indoor unit.
• Condensation effect due to cooling process.
Water fl owing sound during operation.
• Refrigerant fl ow inside the unit.
The room has a peculiar odour.
• This may be due to damp smell emitted by the wall,
carpet, furniture or clothing.
Indoor fan stops occasionally during automatic
fan speed setting.
• This helps to remove the surrounding odour.
Airfl ow continues even after operation has
stopped.
• Extraction of remaining heat from the indoor unit
(maximum 30 seconds).
Operation is delayed a few minutes after
restarting.
• The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam.
• Condensation or evaporation occurs on pipes.
TIMER indicator is always on.
• The timer setting repeats daily once set.
Indoor fan stops occasionally during heating
operation.
• To avoid unintended cooling effect.
POWER indicator blinks before the unit is
switched on.
• This is a preliminary step in preparation for the
operation when the ON timer has been set.
Cracking sound during operation.
• Changes of temperature caused the expansion/
contraction of the unit.
Check the following before calling for servicing.
Symptom
Check
Operation in HEAT/COOL mode is not working
effi ciently.
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet
vents.
Noisy during operation.
• Check if the unit has been installed at an incline.
• Close the intake grille properly.
Remote control does not work.
(Display is dim or transmission signal is weak.)
• Insert the batteries correctly.
• Replace weak batteries.
The unit does not work.
• Check if the circuit breaker is tripped.
• Check if timers have been set.
The unit does not receive the signal from the
remote control.
• Make sure the receiver is not obstructed.
• Certain fl uorescent lights may interfere with signal
transmitter. Please consult authorised dealer.
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please
consult authorised dealer under the
following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the
remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning
properly.
Cleaning instructions / Troubleshooting
The unit stops and the TIMER indicator
blinks.
Use remote control to retrieve error code.
TIMER
SET
CANCEL
ON
OFF
1
2
3
SET CHECK CLOCK
RESET
AC
RC
TIMER
SET
CANCEL
ON
OFF
1
3
SET
CLOCK
RESET
AC
RC
Press for
5 seconds
Press for
5 seconds
to quit
checking
Press until you
hear beep sound,
then write down
the error code
Turn the unit off
and reveal the
error code to
authorised dealer
2
1
3
4
• For certain errors, you may restart the unit for limited
operation with 4 beeps when operation starts.
AMP Air Conditioning
www.ampair.co.uk | [email protected]
Printed in Malaysia
Panasonic Corporation
Website: http://panasonic.net/
© Panasonic Corporation 2013
Authorised representative in EU
Panasonic Testing Centre
Panasonic Marketing Europe GmbH
Winsbergring 15, 22525 Hamburg, Germany
AMP Air Conditioning