Lightware DVI-OPT-TX220-Pro Operation & User’s Manual
Read Online
Read the Lightware DVI-OPT-TX220-Pro Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Fiber Multimedia Extender
DVI-OPT-220-Pro series – User's Manual
2
Important Safety Instructions
Class I Apparatus Construction.
This equipment must be used with a mains power system with a
protective earth connection. The third (earth) pin is a safety feature,
do not bypass or disable it. The equipment should be operated only
from the power source indicated on the product.
To disconnect the equipment safely from power, remove the power
cord from the rear of the equipment, or from the power source. The
MAINS plug is used as the disconnect device, the disconnect device
shall remain readily operable.
There are no user-serviceable parts inside of the unit. Removal of the
cover will expose dangerous voltages. To avoid personal injury, do not
remove the cover. Do not operate the unit without the cover installed.
The appliance must be safely connected to multimedia systems.
Follow instructions described in this manual.
Replacing the AC fuse
Unplug the AC power cord from the device. Locate the AC fuse on the
rear panel. Replace only the AC fuse as indicated on the rear panel.
Connect the power cord to the switcher and to the AC power source.
Make sure the switcher is working properly.
Ventilation
For the correct ventilation and to avoid overheating ensure enough
free space around the appliance. Do not cover the appliance, let the
ventilation holes free and never block or bypass the ventilators (if any).
WARNING
To prevent injury, the apparatus is recommended to securely attach to
the floor/wall or mount in accordance with the installation instructions.
The apparatus shall not be exposed to dripping or splashing and that
no objects filled with liquids, such as vases, shall be placed on the
apparatus. No naked flame sources, such as lighted candles, should
be placed on the apparatus.
CAUTION
AVIS
RISK OF ELECTRIC SHOCK
DO NOT OPEN
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
Waste Electrical & Electronic Equipment
WEEE
This marking shown on the product or its literature,
indicates that it should not be disposed with other
household wastes at the end of its working life. To
prevent possible harm to the environment or human
health from uncontrolled waste disposal, please
separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of material
resources. Household users should contact either the
retailer where they purchased this product, or their local government
office, for details of where and how they can take this item for
environmentally safe recycling. Business users should contact their
supplier and check the terms and conditions of the purchase contract.
This product should not be mixed with other commercial wastes for
disposal.
Caution: Laser product
INVISIBLE LASER RADIATION
AVOID DIRECT EYE EXPOSURE
CLASS 3R LASER PRODUCT
Radiated wavelengths:
778 nm, 800 nm, 825 nm, 850 nm
Output power <= 1mW
Classified by EN 60825-1:2008
Common Safety Symbols
Symbol
Description
Alternating current
Protective conductor terminal
Caution, possibility of electric shock
Caution
Laser radiation
DVI-OPT-220-Pro series – User's Manual
3
Symbol Legend
The following symbols and markings are used in the document:
WARNING!
Safety-related
information
which
is
highly
recommended to read and keep in every case!
ATTENTION! Useful information to perform a successful procedure;
it is recommended to read.
INFO: A notice which may contain additional information. Procedure
can be successful without reading it.
DEFINITION: The short description of a feature or a function.
TIPS AND TRICKS: Ideas which you may have not known yet but can
be useful.
Navigation Buttons
Go back to the previous page. If you clicked on a link previously,
you can go back to the source page by clicking the button.
Navigate to the Table of Contents.
Step back one page.
Step forward to the next page.
Document Information
All presented functions refer to the indicated products. The descriptions
have been made during testing these functions in accordance with the
indicated Hardware/Firmware/Software environment:
Item
Version
Lightware Device Controller (LDC) software
1.22.1
Lightware Bootloader Software
3.3.2
Controller firmware
DVI-OPT-TX220-Pro, DVI-OPT-TX220-ST-Pro
1.1.8
Controller firmware
DVI-OPT-RX220-Pro, DVI-OPT-RX220-ST-Pro
1.1.3
Hardware
DVI-OPT-TX220-Pro, DVI-OPT-TX220-ST-Pro
3.2
Hardware
DVI-OPT-RX220-Pro, DVI-OPT-RX220-ST-Pro
3.1
Document revision: v.2.0
Release date: 22-06-2018
Editor: Judit Barsony
DVI-OPT-220-Pro series – User's Manual
4
1. INTRODUCTION ...................................................................................5
1.1. Description ...................................................................................5
1.2. Box Contents ...............................................................................5
1.3. Features of the Device .................................................................5
1.4. Typical Application .....................................................................6
2. INSTALLATION .....................................................................................7
2.1. Mounting Options ........................................................................7
2.1.1. Truss Mounting ................................................................................. 7
2.1.2. Through Furniture Mounting ............................................................ 7
2.1.3. Rack Shelf Mounting ........................................................................ 7
2.2. Connecting Steps .........................................................................8
10.6. Powering Options .......................................................................8
3. PRODUCT OVERVIEW ........................................................................9
3.1. Transmitters ...............................................................................9
3.1.1. Front View ......................................................................................... 9
3.1.2. Rear View ........................................................................................ 10
3.2. Receivers ....................................................................................11
3.2.1. Front View ....................................................................................... 11
3.2.2. Rear View ........................................................................................ 11
3.3. Electrical Connections .............................................................12
3.3.1. Fiber Optical Connectors .........................................................12
3.3.2. RS-232 Control Port ................................................................12
3.3.3. Alarm Outputs (Receiver) ........................................................12
3.4. Multimode Single Fiber Extender Concept ................................13
4. OPERATION .......................................................................................14
4.1. Powering on ...............................................................................14
4.2. Front Panel LCD Menu Operations ............................................14
4.2.1. Viewing Emulated EDID .................................................................. 14
4.2.2. Learning EDID ................................................................................. 14
4.2.3. Viewing Attached Monitor ............................................................. 15
4.2.4. Switching EDID ............................................................................... 15
4.2.5. Deleting EDID .................................................................................. 15
4.2.6. Laser Enabling ................................................................................ 15
4.2.7. Factory Reset .................................................................................. 15
4.2.8. Device Information ......................................................................... 15
5. SOFTWARE CONTROL – LIGHTWARE DEVICE CONTROLLER ...16
5.1. Install and Upgrade ..................................................................16
5.2. Establishing the Connection .....................................................17
5.3. I/O Parameters Menu .................................................................17
5.4. EDID Menu ...................................................................................18
5.4.1. Sources and Destinations .............................................................. 19
5.4.2. EDID Operations.............................................................................. 19
5.4.3. EDID Summary Window ................................................................. 19
5.4.4. Editing an EDID ............................................................................... 20
5.4.5. Creating an EDID ............................................................................. 20
5.5. Settings ......................................................................................21
5.6. Log Tab .......................................................................................21
5.7. Terminal Menu ...........................................................................22
6. LW2 PROGRAMMERS’ REFERENCE ...............................................23
6.1. LW2 Protocol Description.........................................................23
6.2. General LW2 Commands .............................................................23
6.2.1. Query Control Protocol ................................................................... 23
6.2.2. View Product Type .......................................................................... 24
6.2.3. View Serial Number ....................................................................... 24
6.2.4. View Firmware Version of the CPU ............................................... 24
6.2.5. View Installed Board(s) .................................................................. 24
6.2.6. View Firmware for all Controllers’ ................................................. 24
6.2.7. All Port Status ........................................................................24
6.3. EDID Management .......................................................................25
6.3.1. View Emulated EDID on the Input .................................................. 25
6.3.2. Save EDID to User Memory (Learn EDID) ..................................... 25
6.3.3. Change EDID on Input ................................................................... 25
6.3.4. Watch EDID Validity Table ............................................................. 25
6.3.5. View EDID Header .......................................................................... 26
6.3.6. Download EDID Content from a Location .................................... 26
6.3.7. Upload EDID Content to a Location .............................................. 26
6.3.8. Delete EDID from Memory .......................................................27
6.3.9. Restart the Extender ....................................................................... 27
6.4. Extender Initiated Commands ....................................................27
6.4.1. EDID Status Changed (Transmitter) .............................................. 27
6.4.2. Port Status Changed ...................................................................... 27
6.5. Quick Summary ...........................................................................28
7. FIRMWARE UPGRADE ......................................................................29
7.1. Short Instructions ....................................................................29
7.2. Install the Bootloader .............................................................29
7.3. Detailed Instructions ................................................................29
7.3.1. Establish the Connection ............................................................... 29
7.3.2. Start the Bootloader Software and Follow the Instructions ........ 29
8. TROUBLESHOOTING ........................................................................31
9. TECHNOLOGIES ................................................................................33
9.1. EDID Management .......................................................................33
9.1.1. Understanding the EDID ................................................................. 33
9.1.2. Advanced EDID Management ........................................................ 33
9.2. Pixel Accurate Reclocking .......................................................34
9.3. Serial Management ....................................................................35
9.3.1. General Information ....................................................................... 35
9.3.2. Types of Serial Cables .................................................................... 35
9.3.3. RS-232 Signal Transmission over Lightware Extender Devices .. 35
10. APPENDIX ........................................................................................36
10.1. Specification ............................................................................36
10.2. Factory EDID List .....................................................................37
10.3. Maximum Extension Distances .................................................37
10.4. Mechanical Drawings ..............................................................38
10.5. Further Information ................................................................39
Table of Contents
DVI-OPT-220-Pro series – User's Manual
5
1
Introduction
Thank You for choosing Lightware’s DVI-OPT-220-Pro series device. In the first
chapter we would like to introduce the device highlighting the most important
features in the below listed sections:
Ý
Description
Ý
Box Contents
Ý
Features of the Device
Ý
Typical Application
1.3. Features of the Device
Advanced EDID Management
The user can emulate any EDID on the inputs
independently, read out and store any attached
monitor's EDID in 100 internal memory locations,
upload and download EDID files using Lightware Device
Controller software.
Pixel Accurate Reclocking
Each output has a clean, jitter free signal, eliminating
signal instability and distortion caused by long cables
or connector reflections.
1080p
HDTV
Supports all HDTV resolutions
720p, 1080i, 1080p etc. without HDCP encoding.
Unencrypted signals up to 165 MHz pixel clock
frequency - regardless of the resolution - are passed
through.
Single Fiber Technology
All of the high-speed TMDS data lanes are transmitted
using only one multimode 50/125 fiber optical cable.
Break-out LC connector
A break-out LC fiber optical connector allows users to
transmit the signal of two transmitters in one Neutrik
OpticalCON Duo cable. For more details see the
Application Example of Break-out Connector section.
Local Monitor Output
User can attach a local monitor to observe the video
signal sent through the fiber optical cable. The
resolution and clock frequency are the same on DVI
and fiber optical connectors, no internal scaling or
conversion is applied.
1.1. Description
Lightware DVI-OPT-TX220-Pro is a Single Link DVI optical transmitter
and DVI-OPT-RX220-Pro is a Single Link DVI optical receiver. They use
a single multimode fiber to extend DVI signals.
DVI-OPT-TX220-Pro and DVI-OPT-RX220-Pro are assembled with
Neutrik NO2-4FDW type LC duplex fiber connector, while DVI-OPT-
TX220-ST-Pro and DVI-OPT-RX220-ST-Pro are assembled with ST fiber
optical connector.
The extenders conform to DVI 1.0 specification, and handle signals
between 25 - 165MHz pixel clock frequency: from 640x480@60Hz to
1920x1200@60Hz or 2048x1080@60Hz resolutions.
The extenders have an RS-232 serial port for remote control
applications and firmware upgrade. The transmitter has a control
panel for local control operation as well.
Model Denomination
1.2. Box Contents
*Only for the receiver devices.
DVI-OPT-TX-220-ST-Pro
Model
number
AV extension over fiber
DVI video interface
Transmitter unit
ST fiber connector
Extender unit
IEC power cable
RS232 9-pole D-SUB
male to female
straight serial cable
Phoenix® 3-pole
connector
type MC 1.5/3-ST-3.5*
Safety & Warranty Info,
Quick Start Guide
Safety and
Warranty
Info
Quick
Start
Guide
DVI-OPT-220-Pro series – User's Manual
6
1.4. Typical Application
Application Examples
▪
Long distance lossless DVI signal transmission
▪
Ground loop isolation
▪
Multi-room video control
▪
Professional AV systems, conference rooms
▪
Rental and Staging
▪
Digital signage
1.4.1. Typical Stand-Alone Application with Break-Out Connection
RS-232
LOCAL CONTROL
RoHS
Made in EU, HU
RS-232
LOCAL CONTROL
RoHS
Made in EU, HU
DVI cabIe
DVI cabIe
DVI cabIe
DVI cabIe
DVI cabIe
DVI cabIe
DVI cabIe
DVI cabIe
NEUTRIK®
opticalCON DUO
HYBRID up to 2500m
Power cable
Power cable
Power cable
DVI-OPT-TX220-Pro
DVI-OPT-TX220-Pro
DVI-OPT-RX220-Pro
DVI-OPT-RX220-Pro
Projector
DVI Monitor
DVI Monitor
DVI Monitor
DVI Monitor
DVI Monitor
PC or Mac
PC or Mac
Remote power
LC-LC fiber
optical cable
LC-LC fiber
optical cable
1.4.2. Integrated System Operation for DVI Extenders
MX-DVI-OPT-IB-LC
8CH OPTICAL INPUT BOARD
LASER DETECT
RECEIVER ACTIVE
SIGNAL PRESENT
L. D.
R. A.
SIGNAL
IN1 IN2
IN7 IN8
IN5 IN6
IN3 IN4
SC 50/125 MULTIMODE
8CH OPTICAL INPUT BOARD
SC 50/125 MULTIMODE
8CH OPTICAL INPUT BOARD
IN1 IN2
IN7 IN8
IN5 IN6
IN3 IN4
LASER DETECT
RECEIVER ACTIVE
SIGNAL PRESENT
MX-DVI-OPT-IB-ST
4 CH DUAL LINK DVI INPUT BOARD
MX-DVIDL-IB
LC 50/125 MULTIMODE
LASER DETECT
RECEIVER ACTIVE
SIGNAL PRESENT
L. D.
R. A.
SIGNAL
IN1 IN2
IN7 IN8
IN5 IN6
IN3 IN4
IN1 IN2
IN7 IN8
IN5 IN6
IN3 IN4
LASER DETECT
RECEIVER ACTIVE
SIGNAL PRESENT
MX-DVI-OPT-IB-SC
OUT1 OUT2
OUT7 OUT8
OUT5 OUT6
OUT3 OUT4
8CH OPTICAL OUTPUT BOARD
8CH OPTICAL OUTPUT BOARD
SC 50/125 MULTIMODE
SC 50/125 MULTIMODE
MX-DVI-OPT-OB-ST
LASER DETECT
SIGNAL PRESENT
L. D.
SIGNAL
MX-DVI-TP-OB
8CH OPTICAL RECLOCKING
OUTPUT BOARD
MX-DVI-OPT-OB-NT
LASER DETECT
SIGNAL PRESENT
L. D.
SIGNAL
OUT1 OUT2
OUT7 OUT8
OUT5 OUT6
OUT3 OUT4
MX-DVI-OPT-OB-LC
8CH OPTICAL OUTPUT BOARD
LASER DETECT
L. D.
L. D.
OUT1 OUT2
OUT7 OUT8
OUT5 OUT6
OUT3 OUT4
LASER DETECT
MX-DVI-OPT-OB-SC
OUT1 OUT2
OUT7 OUT8
OUT5 OUT6
OUT3 OUT4
RS-232
LOCAL CONTROL
RoHS
Made in EU, HU
Service LAN
SC MM OUT DC 5V
PC
PC
PC
DVI Monitor
Power cable
Power cable
DVI-OPT-RX220-Pro
Projector
Projector
DVI-OPT-TX220-Pro
DVI cabIe
DVI cabIe
DVI Monitor
DVI Monitor
SC-SC fiber
optical cable
NEUTRIK®
opticalCON DUO
HYBRID up to 2500m
DVI cabIe
DVI cabIe
DVI cabIe
SC-SC fiber
optical cable
DVI cabIe
Power cable
NEUTRIK®
opticalCON
DUO HYBRID
up to 2500m
DVI-OPT-220-Pro series – User's Manual
7
2
Installation
The chapter is about the installation of the device and connecting to other
appliances, presenting also the mounting options and further assembly steps:
Ý
Mounting Options
Ý
Connecting Steps
Ý
Powering Options
2.1. Mounting Options
Devices can be mounted several ways, depending on the application.
Besides using with rack shelf a mounting bracket is available which
offers easy mounting on truss systems with standard clamps or using
the unit built in to furniture.
Under-desk double mounting kit
Mounting bracket
2.1.1. Truss Mounting
Step 1. Fasten the mounting bracket on the
side of the unit with the provided
screws.
Step 2. Use a bolt to attach a standard clamp.
(The clamp is not supplied with the
device)
Step 3. Mount the unit on the truss with the
clamp.
2.1.2. Through Furniture Mounting
To get a good result, the thickness of the
board should not exceed 60 millimeters.
Step 1. Cut a suitable hole in the board.
Step 2. Attach the mounting bracket on the
side of the unit with the provided
screws.
Step 3. Mount the unit on the board.
Step 4. Loosen the screws a little on the
bracket and adjust the unit to line
up with the front of the board.
2.1.3. Rack Shelf Mounting
Step 1. Turn the unit upside down.
Step 2. Put the rack shelf upside down on the unit, and position it to get
the mounting holes aligned.
Step 3. Fasten the unit on the rack shelf with the provided screws.
Step 4. Mount the rack shelf in the rack.
Standard rack installation
ATTENTION! Always use all the four screws for fixing the rack shelf
ears to the rack rail. Choose properly sized screws for mounting.
Keep minimum two threads left after the nut screw.
POWER
SOURCE CONNECTED (pin14 +5V)
LASER ACTIVE
DVI INPUT SIGNAL PRESENT
ENTER
DVI Multimode Fiber Transmitter
DVI-OPT-TX220-ST-Pro
DVI-OPT-TX220-PR
SN:06342203
POWER
SOURCE CONNECTED (pin14 +5V)
LASER ACTIVE
DVI INPUT SIGNAL PRESENT
ENTER
DVI Multimode Fiber Transmitter
DVI-OPT-TX220-ST-Pro
DVI-OPT-TX220-PR
SN:06342204
POWER
SOURCE CONNECTED (pin14 +5V)
LASER ACTIVE
DVI INPUT SIGNAL PRESENT
ENTER
DVI Multimode Fiber Transmitter
DVI-OPT-TX220-ST-Pro
DVI-OPT-TX220-PR
SN:06342203
POWER
SOURCE CONNECTED (pin14 +5V)
LASER ACTIVE
DVI INPUT SIGNAL PRESENT
ENTER
DVI Multimode Fiber Transmitter
DVI-OPT-TX220-ST-Pro
DVI-OPT-TX220-PR
SN:06342203
DVI-OPT-220-Pro series – User's Manual
8
2.2. Connecting Steps
DVI-OPT-TX220-Pro
OPT
Confidence monitor
Power
Power
RS-232
DVI
POWER
SOURCE CONNECTED (pin14 +5V)
LASER ACTIVE
DVI INPUT SIGNAL PRESENT
ENTER
DVI Multimode Fiber Transmitter
DVI-OPT-TX220-Pro
PC
DVI
DVI Multimode Fiber Receiver
DVI-OPT-RX220-ST-Pro
MONITOR 2 HOTPLUG
DVI SIGNAL PRESENT
MONITOR 1 HOTPLUG
GREEN: LASER DETECTED
RED BLINKING: LOW LASER LEVEL
POWER
Projector
DVI
Power
Power
DVI-OPT-RX220-Pro
Transmitter side
Receiver side
OPT
Connect a compatible Lightware fiber
receiver unit with a multimode fiber cable
to the fiber output connector. Connect
an LC optical cable to the Channel A LC
connector, or use a Neutrik opticalCon Duo
cable.
DVI
Connect the DVI source (e.g. PC) to the
DVI INPUT connector.
DVI
Optionally connect a display device to the
LOCAL MONITOR OUTPUT connector.
RS-232 Connect a straight serial cable to the
RS-232 LOCAL CONTROL and the PC in
order to control the transmitter.
Power
Power on the fiber receiver and the
connected display devices. They will
display the picture from the DVI source
(computer).
OPT
Connect a compatible Lightware fiber
transmitter unit with a multimode fiber
cable to the FIBER INPUT connector.
Connect an LC optical cable to the
Channel B LC connector, or use a
Neutrik opticalCON Duo cable.
DVI
Connect the DVI display devices to the
DVI OUTPUT connectors.
Power
See the powering options in the next
section.
WARNING! Please do not look directly into
the fiber optical connector if the cable is
connected to the transmitter only and the laser
is active.
2.3. Powering Options
When building an electronic system, make sure that all of the devices are powered down before connecting
them. Powered on devices may have dangerous voltage levels, that can damage sensitive electronic circuits.
Transmitter
After the system is complete, connect the IEC power cable to the extender unit and then to the power outlet.
The unit is immediately powered on.
After the extender units are initialized, the attached DVI source and monitor can be powered on.
Receiver
Two power source can be chosen to supply the receiver unit:
To use the built-in power supply
To power the unit remotely
INFO: The laser becomes enabled any time the transmitter is powered on, disregarding that it was disabled
before or not. This is done to avoid accidental laser loss problems.
INFO: If neither the LEDs nor the LCD light up upon power-up, the unit is most likely damaged and further
use is not advised. Please contact [email protected].
Power
Connect IEC Power Cable
DVI-OPT-RX220-Pro
2
1
Set the power selector
switch to I (only on
DVI-OPT-RX220-Pro)
Connect a DVI-OPT-TX220-Pro
with Neutrik hybrid fiber cable
DVI-OPT-RX220-Pro
2
1
DVI-OPT-TX220-Pro
Set the power selector
switch to II (only on
DVI-OPT-RX220-Pro)
Power
A
B
DVI INPUT
LOCAL MONITOR OUTPUT
Remote power for receiver DC OUT +15V
GND
Remote power for receiver DC OUT +15V
GND
LASER
ACTIVE
FIBER OUTPUT (A):
50/125 MULTIMODE
B
A
Laser Radiation
850 nm, Class 3
3. Product Overview
DVI-OPT-220-Pro series – User's Manual
9
3
Product Overview
The following sections are about the physical structure of the device, input/
output ports, and connectors:
Ý
Transmitters
Ý
Receivers
Ý
Electrical Connections
Ý
Multimode Single Fiber Extender Concept
3.1. Transmitters
3.1.1. Front View
INFO: The front view of DVI-OPT-TX220-Pro and DVI-OPT-TX220-ST-Pro is almost the same; the only
difference is the type designation.
1 Power LED
Power LED lights green when the unit is powered on.
2 Menu display Displays status information and menu operation. See Front Panel LCD Menu Operations
section for more information.
3 Status LEDs
For more details, see the legend for the Status LEDs below.
4 Menu
navigation
Up, down, left, right and enter buttons for menu navigation. See Front Panel LCD Menu
Operations section for more information.
Status LEDs
POWER
green
on
The transmitter unit is powered and ready to use.
off
The transmitter unit is NOT powered on.
LASER ACTIVE
green
on
It gives feedback about the operation of the optical module (laser is enabled), that means
the laser radiates invisible waves. Avoid direct eye contact with the optical connectors!
off
Laser module is not active (laser is disabled on the output port).
DVI INPUT SIGNAL PRESENT
green
on
Indicates when a valid DVI signal is detected on the DVI INPUT connector.
off
There is no valid DVI signal on the DVI INPUT connector.
SOURCE CONNECTED (pin14 +5V)
green
on
Indicates if a DVI source is connected to the unit, it is powered on and sends +5V signal to pin
14 of the input DVI connector.
off
The source does not send +5V signal to the pin 14 of the input DVI connector.
POWER
SOURCE CONNECTED (pin14 +5V)
LASER ACTIVE
DVI INPUT SIGNAL PRESENT
ENTER
DVI Multimode Fiber Transmitter
DVI-OPT-TX220-ST-Pro
DVI-OPT-TX220-PR
SN:06342203
1
2
4
3
3. Product Overview
DVI-OPT-220-Pro series – User's Manual
10
3.1.2. Rear View
DVI-OPT-TX220-Pro
DVI-OPT-TX220-ST-Pro
A
B
DVI INPUT
LOCAL MONITOR OUTPUT
100-240 V AC
FUSE: F 1 A
50/60 Hz 0.7 A
Remote power for receiver DC OUT +15V
GND
Remote power for receiver DC OUT +15V
GND
LASER
ACTIVE
FIBER OUTPUT (A):
50/125 MULTIMODE
RoHS
Made in EU, HU
B
A
LOCAL CONTROL
RS-232
Laser Radiation
850 nm, Class 3
1
2
6
7
3
4
5
1 AC connector
Standard IEC power connector. Accepts 100 to 240 Volts, 50 or 60 Hz power sources.
2 Serial port
9-pole D-SUB female connector for serial RS 232 communication; see RS-232
Control Port for more details.
3 DVI input
29-pole DVI-I connector, however only digital pins are internally connected. Connect
single link DVI source. The unit has minimal cable compensation ability, hence the
maximum recommended cable length – in compliance with the DVI standard – is
5 m. See DVI Inputs and Outputs section for more information.
4 Monitor output
29-pole DVI-I connector, however only digital pins are internally connected. A local
display device can be connected to check the outgoing signal. The resolution and
pixel clock frequency are the same on the DVI and Neutrik connectors, no internal
scaling or conversion is applied to the signal. See DVI Inputs and Outputs section
for more information.
5 Laser Active LED
on
It gives feedback about the operation of the optical module (laser is
enabled), that means the laser radiates invisible waves. Avoid direct eye
contact with the optical connectors!
off
Laser module is not active (laser is disabled on the output port).
6 Break-out
connector
The break-out LC connector is internally connected to output B of the Neutrik
connector with a multimode 50/125 fiber optical patch cable. User can connect the
signal of another fiber optical transmitter to pass it through a double-core Neutrik
fiber optical cable. See Typical Stand-Alone Application with Break-Out Connection
and Application Example of Break-out Connector section for more details.
7 Neutrik
connector
Neutrik NO2-4FDW type LC duplex connector; carrying the signals of up to two
transmitters. See Fiber Optical Connectors section for more details.
8 ST connector
ST fiber optical connector. Carrying the signals between transmitter and receiver.
See Fiber Optical Connectors section for more information.
LOCAL CONTROL
RS-232
DVI INPUT
LOCAL MONITOR OUTPUT
100-240 V AC
FUSE: F 1 A
50/60 Hz 0.7 A
LASER
ACTIVE
FIBER OUTPUT :
50/125 MULTIMODE
RoHS
Made in EU, Hungary
Laser Radiation
850 nm, Class 3
3
4
5
8
2
1
3. Product Overview
DVI-OPT-220-Pro series – User's Manual
11
3.2. Receivers
3.2.1. Front View
INFO: The front view of DVI-OPT-RX220-Pro and DVI-OPT-RX220-ST-Pro is almost the same; the only
difference is the type designation.
Status LEDs
POWER LED
green
on
The receiver unit is powered and ready to use. It does not indicate whether the device is
operating properly.
off
The receiver unit is NOT powered on.
LASER LED
green
on
It indicates if a laser beam is detected.
red
blinking
No laser beam is detected, or laser level is too low.
DVI SIGNAL PRESENT
green
on
Indicates if a valid DVI clock signal can be recovered from the fiber optical signal.
off
No valid DVI signal on the fiber input.
MONITOR 1 HOTPLUG, MONITOR 2 HOTPLUG
green
on
Each LED indicates if a display device (or repeater, etc.) is connected to the
corresponding DVI output and they send a valid Hot Plug Signal on Pin 16 through
the DVI cables.
off
The connected sink does not send +5V signal to the pin 14 of the DVI output.
DVI Multimode Fiber Receiver
DVI-OPT-RX220-ST-Pro
MONITOR 2 HOTPLUG
DVI SIGNAL PRESENT
MONITOR 1 HOTPLUG
GREEN: LASER DETECTED
RED BLINKING: LOW LASER LEVEL
POWER
3.2.2. Rear View
DVI-OPT-RX220-Pro
DVI-OPT-RX220-ST-Pro
1 AC
connector
Standard IEC power connector. Accepts 100 to 240 Volts, 50 or 60 Hz power sources.
2 DVI
outputs
29-pole DVI-I connector, however only digital pins are internally connected. The resolution and
pixel clock frequency are the same on both DVI connectors; no internal scaling or conversion
is applied to the signal.
3 Alarm
outputs
DVI signal detection and laser detection signals with ground reference are available on a
3-pole Phoenix connector. See Alarm Outputs (Receiver) section for more information.
4 Serial port 9-pole D-SUB female connector for serial RS-232 communication; see RS-232 Control Port for
more details.
5 Break-out
connector
The break-out LC connector is internally connected to output B of the Neutrik connector with a
multimode 50/125 fiber optical patch cable. The user can connect the signal of another fiber
optical transmitter to pass it through a double-core Neutrik fiber optical cable. See Fiber Optical
Connectors and Application Example of Break-out Connector section for more details.
6 Neutrik
connector
Neutrik NO2-4FDW type LC duplex connector. Carrying the signals of up to two transmitters.
See Fiber Optical Connectors section for more details.
7 Power
selector
The receiver’s power source can be selected with this switch. In position I the receiver unit is
powered with its own built-in power supply. In position II the receiver unit is powered through
hybrid fiber cable. See Powering Options section for more information.
8 ST
connector
ST fiber optical connector. Carrying the signals between transmitter and receiver. See Fiber
Optical Connectors section for more information.
5
2
2
3
7
6
4
1
DVI OUT 1
DVI OUT 2
RoHS
Made in EU, Hungary
FIBER INPUT
50/125 MULTIMODE
100-240 V AC 50/60 Hz 0.7 A
FUSE: F 1 A
RS-232
1:DVI DETECT +5V
2:LASER DETECT (+5V)
3:GND
3
2
1
( )
4
1
2
2
3
8
3. Product Overview
DVI-OPT-220-Pro series – User's Manual
12
3.3. Electrical Connections
3.3.1. Fiber Optical Connectors
DVI-OPT220-Pro series devices transmit the video signal via multimode
50/125 fiber optical cable.
Neutrik OpticalCON Duo Connector
DVI-OPT-RX220-Pro and DVI-OPT-TX220-Pro models
have Neutrik opticalCON connector (NO2-4FDW type
LC duplex) and LC ODVA connector have two fiber
channels, channel A and channel B. Only one channel
is used (from channel A on the transmitter to channel B
on the receiver). Neutrik opticalCON DUO is compatible
with 2x LC connector.
Pin Assignment of Neutrik OpticalCON Duo Connector
Pin
Signal
1
GND
2
Remote power for receiver DC out +15V
3
Remote power for receiver DC out +15V
4
GND
A
Channel A
B
Channel B
LC Connector
One channel of the Neutrik connector is not used by the extenders
for signal transmission and it is internally connected to the LC
break-out connector. For more information about break-out
connector see Application Example of Break-out Connector
section.
SC Connector
DVI-OPT-RX220-ST-Pro
and
DVI-OPT-TX220-ST-Pro
models
supplied with ST optical connectors.
3.3.2. DVI Inputs and Outputs
29-pole DVI-I connectors, however only digital
pins are internally connected. This way, user can
plug in any DVI connector, but keep in mind that
analog signals (such as VGA or RGBHV) are NOT
processed.
INFO: Always use high quality DVI cable for connecting sources and
displays!
B
A
1
4
3.3.3. RS-232 Control Port
Devices can be remote controlled through
industry standard 9-pin D-SUB female connector
located on the rear panel of the unit. Please use a
standard RS-232 Male to Female cable (straight
through).
D-sub connector pin assignment for standard RS-232
Pin nr.
Pinout
1
NC - non-connected
2
TX data transmit (output)
3
RX data receive (input)
4
DTR (Internally connected to Pin 6)
5
GND signal ground (shield)
6
DSR (Internally connected to Pin 4)
7
RTS (Internally connected to Pin 8)
8
CTS (Internally connected to Pin 7)
9
NC - non-connected
INFO: DVI-OPT-220-Pro extenders are DCE unit according to its pin-out.
For more information see Serial Management section.
INFO: Factory default settings are the same in the transmitter and
receiver: 9600 Baud, 8 data bit, 1 stop bit, no parity.
3.3.4. Alarm Outputs (Receiver)
TTL outputs can be used to give a signal to any third-party
device. Separate signals indicate the detected laser and
the presence of the received DVI signal.
Alarm Outputs
DVI Detect: Indicates when a valid DVI clock signal is extracted
from the fiber optical signal. Logic 1 (+5V) means that a DVI signal
is detected. Logic 0 (GND) means that a valid DVI signal cannot be
extracted from the optical signal.
Laser Detect: Indicates when a laser beam is detected at the Neutrik
connector. Logic 1 (+5V) means that a laser beam with the appropriate
wavelength is detected. Logic 0 (GND) means that either there is no
laser signal or its level is too low to be recognized.
GND: Ground reference signal for alarm outputs. Connected to chassis
ground.
Compatible Plug Type
Phoenix® Combicon series (3.5mm pitch), type: MC 1.5/3-ST-3.5
DVI signal present
Laser detect
Pin 1: DVI detect (+5V)
Pin 2: Laser detect (+5V)
Pin 3: GRD
+5V
+5V
300Ω
300Ω
3. Product Overview
DVI-OPT-220-Pro series – User's Manual
13
3.4. Multimode Single Fiber Extender Concept
DVI-OPT-220Pro series extenders support multimode fiber optical interface to transmit digital A/V signals.
For more details about the supported cable extension see Maximum Extension Distances section.
Port Diagram of Optical Interface
The Neutrik opticalCON DUO cable has two fiber channels, named channel A and channel B. Since Lightware
fiber extenders use only one fiber for signal transmission, the other fiber can be used by other optical devices.
The unused fiber channel is accessible by the break-out connector.
INFO: Red line shows the main direction of the video signal. The blue line represents the optical signal via
break-out connector, which direction is not specified.
B
A
DVI-D
IN
DVI-D
OUT
DVI-D
OUT 1.
DVI-D
OUT 2.
B
A
A
B
Break-out
connector
Break-out
connector
Neutrik
connector
DVI-OPT-RX220-Pro
DVI-OPT-TX220-Pro
Other fber device
Other fber device
Neutrik
connector
DVI
Splitter
Reclocker
DVI
Splitter
Application Example of Break-out Connector
Using this feature, it is possible to transmit two different A/V signal from one transmitter pair to another
receiver pair with only one Neutrik opticalCON DUO cable. See the application example below.
Transmitter Unit (DVI-OPT-TX220-Pro)
The transmitter’s laser driver sends the signal through
Channel A. Channel B is directly connected to the
break-out connector with a fiber optical cable inside
the unit. Any optical signal can be transferred through
this channel in any direction.
Receiver Unit (DVI-OPT-RX220-Pro)
The receiver’s laser sensor gets the signal through
Channel B. Channel A is directly connected to the
break-out connector with a fiber optical cable inside
the unit. Any optical signal can be transferred through
this channel in any direction.
A
B
DVI INPUT
LOCAL MONITOR OUTPUT
LOCAL CONTROL
RS-232
A
B
DVI INPUT
LOCAL MONITOR OUTPUT
LOCAL CONTROL
RS-232
LC-LC fiber
optical cable
LC-LC fiber
optical cable
Neutrik opticalCON up to 2500m
Source 1.
Sink 1.
Sink 2.
Source 2.
A/V Signal 1.
A/V Signal 2.
DVI
DVI
DVI
DVI
Transmitter side
Receiver side
A
B
A
B
A
LC-LC fiber
optical cable
LC-LC fiber
optical cable
Neutrik opticalCON up to 2500m
Transmitter side
Receiver side
DVI-OPT-220-Pro series – User's Manual
14
4.1. Powering on
Connect the power cord to the AC input connector; the extender is
immediately powered on. After the self-test, the last configuration is
loaded automatically.
The receiver has more powering possibilities. For more details, see
Powering Options section.
4.2. Front Panel LCD Menu Operations
The extenders have an LCD menu and navigation buttons which make
the possibility to change certain settings and display basic information
via the front panel.
Display
Front panel LCD has 2 lines and 16
characters in each line. The name of
the menu item is always displayed
in the first line.
Navigation
Buttons
Functions
up
Toggle between menu items.
down
left
Modify the settings in each menu
item.
right
enter
Execute changes.
Idle state
If no button is pressed for 10
seconds, the display returns to its
idle state and the Emulated EDID is
shown.
LCD menu structure
Learn EDID U01
[email protected]
PRESENT
ENTER
EmulatedEDID F49
UniversalEDID
Emulated EDID
Learn EDID
Attached Monitor
Switch EDID
Delete EDID
Laser Enable
Factory Reset
Device Information
4
Operation
This chapter is about the powering and operating of the device describing the
functions which are available by the front/rear controls:
Ý
Powering on
Ý
Front Panel LCD Menu Operations
4.2.1. Viewing Emulated EDID
This is the default display in
idle state. If needed use the left
and right buttons to select
the EMULATED EDID menu. The
currently emulated EDID is shown.
Three screens toggle automatically
showing the preferred resolution,
the name of the display and a
three letter abbreviation assigned
to the manufacturer. Lightware
factory presets have LWR as the
manufacturer.
4.2.2. Learning EDID
The EDID of the display device that is attached to the local monitor
output can be stored in one of the 49 user memory slots.
Step 1. Use the left and right
buttons to select the
LEARN EDID menu.
Step 2. Select a memory address
using the up and down
buttons. Hold down the up
and down buttons to scroll
faster. Three screens toggle
automatically showing the
preferred
resolution,
the
name of the display and
a three letter abbreviation
assigned to the manufacturer.
Step 3. Press ENTER to store the
EDID in the selected slot.
If a filled slot is selected,
then the ENTER button will
overwrite the previously stored EDID.
INFO: The factory preset EDIDs cannot be changed by the user. Only
addresses from U1 to U49 are user programmable.
INFO: EDIDs are stored in a multiple programmable non-volatile
memory, the saved EDID’s will not be lost after switching off the
transmitter. Please note that if you upgrade the firmware, the saved
EDID’s will be deleted from the user memory.
INFO: If the selected user memory is not empty, the new EDID will
overwrite the previously stored EDID.
EmulatedEDID F49
[email protected]
EmulatedEDID F49
UniversalEDID
EmulatedEDID F49
LWR
EDID Learned!
Learn EDID U01
[email protected]
Learn EDID U01
24WMGX3
Learn EDID U01
NEC
DVI-OPT-220-Pro series – User's Manual
15
4.2.3. Viewing Attached Monitor
Use the left and right buttons
to select the ATTACHED MONITOR
menu.
Information about the monitor that
is attached to the local monitor
output is shown. If no monitor is
connected, then the last attached
monitor’s information is displayed.
Three screens toggle automatically
showing the preferred resolution,
the name of the display and a three
letter abbreviation assigned to the
manufacturer.
4.2.4. Switching EDID
Step 1. Use the left and right
buttons to select the SWITCH
EDID menu.
Step 2. Use the up and down
buttons to select a filled
memory slot. Hold down the
up and down buttons to
scroll faster. Three screens
toggle automatically showing
the preferred resolution, the
name of the display and
a three letter abbreviation
assigned to the manufacturer.
Step 3. Press ENTER to emulate
selected EDID.
After every EDID change, the transmitter toggles the HOT PLUG signal
for approx. 1 sec. Some graphic cards or DVD players do not sense
the HOT PLUG signal, and even if EDID has been changed, the set
resolution is not affected. In this case the source device must be
restarted, or powered OFF and ON again.
INFO: Location D02 has a special function. If a monitor is connected
to LOCAL MONITOR OUT, then its EDID is copied to location D02.
If no monitor is connected to the output then the last connected
monitor’s EDID is shown.
INFO: Lightware factory presets have LWR as the manufacturer.
Attached Monitor
[email protected]
Attached Monitor
24WMGX3
Attached Monitor
NEC
4.2.5. Deleting EDID
Step 1. Use the left and right
buttons to select the Delete
EDID menu.
Step 2. Use the up and down
buttons to select a filled
memory slot. Hold down
the up and down
buttons to scroll faster.
Three
screens
toggle
automatically showing the
preferred resolution, the name of the display and a three letter
abbreviation assigned to the manufacturer.
Step 3. Press
ENTER
to
delete
selected EDID, then use the
up and down buttons to
change YES/NO.
Step 4. Press Enter to execute YES/
NO switch.
INFO: The factory preset EDIDs cannot be deleted by the user.
INFO: If such an EDID is deleted that is currently emulated on the
input, the EDID will be deleted from the location (e.g. from the user
memory). But the EDID on the input will not be changed until a new,
valid EDID is selected to emulate.
4.2.6. Laser Enabling
Step 1. Use the left and right
buttons to select the LASER
ENABLE menu.
Step 2. Use the up and down
buttons to change ON/OFF.
The selected value will blink.
Step 3. Press ENTER to execute ON/OFF switch.
Delete EDID U51
[email protected]
Delete EDID U51
LCD1970NXP
Delete EDID U51
NEC
EDID Deleted!
Confirm Delete?
YES
Laser Enable
ON
Laser Changed!
4.2.7. Factory Reset
Step 1. Use the left and right
buttons to select the
FACTORY RESET menu.
Step 2. Press the ENTER button to
reset the device to the factory preset values.
Step 3. A completion message will
appear, and then the unit
reboots.
This action sets all parameters to factory default values:
▪
Emulated EDID: F49 – Universal EDID
▪
Learn EDID:
U01
▪
Switch EDID:
D02
▪
Delete EDID:
U01
▪
Laser Enable:
ON
4.2.8. Device Information
The device name is displayed
in the first line. Two screens
toggle automatically showing the
firmware/hardware versions and
the serial number.
Factory Reset
OK
Factory Defaults
Reloaded!!!
DVI-OPT-TX220-PR
FW:1.1.8 HW:3.2
DVI-OPT-TX220-PR
SN:06342203
Switch EDID F33
[email protected]
Switch EDID F33
1440x576i@50
Switch EDID F33
LWR
EDID Switched!
5. Software Control – Using Lightware Device Controller
DVI-OPT-220-Pro series – User's Manual
16
5
Software Control – Using Lightware Device
Controller
The extender can be controlled by a computer through the LAN, RS-232 and
USB ports using Lightware Device Controller (LDC). The software can be
installed on a Windows PC or Mac OS X. The application can be downloaded
from www.lightware.com. The Windows and the Mac versions have the same
look and functionality.
Ý
Install and Upgrade
Ý
Establishing the Connection
Ý
I/O Parameters Menu
Ý
EDID Menu
Ý
Settings
Ý
Log Tab
Ý
Terminal Menu
5.1. Install and Upgrade
Installation for Windows OS
Step 1. Run the installer. If the User Account Control drops a pop-up
message click Yes.
Step 2. During the installation you will be prompted to select the type
of the installation: normal and the snapshot install:
Normal install
Snapshot install
Available for Windows and Mac OS X
Available for Windows
The installer can update only this
instance
Cannot be updated
Only one updateable instance can
exist for all users
Different versions can be
installed for all users
Comparison of the Installation Types
ATTENTION! Using the Normal install as the default value is highly
recommended.
Installation for Mac OS X
INFO: After the installation, the Windows and the Mac application
has the same look and functionality. This type of the installer is
equal with the Normal install in the case of Windows and results an
updateable version with the same attributes.
Mount the DMG file with double clicking on it and drag the LDC icon
over the Applications icon to copy the program into the Applications
folder. If you want to copy the LDC into another location just drag the
icon over the desired folder.
The Upgrading of the LDC
Step 1. Run the application.
The
Device Discovery
window
appears automatically and the
program checks the available
updates on Lightware’s website
and opens the update window if
the LDC found updates.
The current and the update
version number can be seen at
the top of the window and they
are shown in this window even
with the snapshot install.
The Update window can be opened manually by clicking the question
mark and the Update button.
Step 2. Set the desired update setting in the Options section.
▪
When the Check for updates automatically option is marked, the
LDC tries to find a new version after startup.
▪
If you want to postpone the update, set the reminder by the drop
down list.
▪
If necessary, the proxy settings are available by clicking the
Setup button.
Step 3. Click the Download update button to start the downloading.
Step 4. When the download process finished, the Download Update
button changes to Launch update. Click it on to install the new
version.
5. Software Control – Using Lightware Device Controller
DVI-OPT-220-Pro series – User's Manual
17
5.2. Establishing the Connection
The extenders can be controlled from a Windows or OS X based computer using the LDC through RS 232
connection.
Step 1. Connect the appliance and the computer via RS-232 port with standard Male to Female cable (straight
through).
Step 2. Run the controller software.
Step 3. Device discovery window appears automatically.
Device Discovery Window
Step 4. Click on the Serial Devices tab to reach the list of the devices which are connected via serial port.
Step 5. The device name and serial number can be inquired by pressing the query button next to the appropriate
COM port.
Step 6. Select the device and click on the Connect button.
5.3. I/O Parameters Menu
After connecting to the device, this menu appears by default showing the current state of input and output
ports. The port bar on the right side shows the available input and output ports.
I/O Parameters Menu
Port settings (transmitter)
Input1:
The state of the incoming signal is displayed.
Output1:
The port represents the fiber output. The laser can be enabled or disabled. This setting has
the same effect as changing it on the front panel.
Output2:
Connected local monitor’s state is displayed (hotplug detected or not).
5. Software Control – Using Lightware Device Controller
DVI-OPT-220-Pro series – User's Manual
18
Port settings (receiver)
Input1:
The window shows the adjustable parameters for the input.
Output1 and 2: Connected monitors’ state are displayed (hotplug detected or not).
Input Parameters
Parameters
The factory default settings give good results in most cases. Please consult Lightware support for further
information if encountering problems with signal quality.
Reload factory defaults
Default values are reloaded to the input.
5.4. EDID Menu
Advanced EDID Management can be accessed by selecting the EDID menu. There are two panels: left one
contains Source EDIDs, right one contains Destination slots where the EDIDs can be emulated or copied.
Control buttons
Export
Exporting an EDID (save to a
file)
Executing EDID emulation or
copying (Transfer button)
Import
Importing an EDID (load from a
file)
Delete selected
Deleting EDID (from User
memory)
Info
Display EDID Summary window
Select all
Selecting all memory places
in the right panel
Edit
Opening Advanced EDID Editor
with the selected EDID
Select none
Selecting none of the
memory places in the right
panel
Create
Opening Easy EDID Creator
5. Software Control – Using Lightware Device Controller
DVI-OPT-220-Pro series – User's Manual
19
Importing an EDID
Previously saved EDID (*.bin, *.dat or *.edid file) can be uploaded to the user memory:
Step 1. Select the User tab in the left panel and select a memory slot.
Step 2. Press the Import button below the Source panel.
Step 3. Browse the file in the opening window then press the Open button. Browsed EDID is imported into the
selected User memory.
ATTENTION! The imported EDID overwrites the selected memory place even if it is not empty.
Deleting EDID(s)
The EDID(s) from User memory can be deleted as follows:
Step 1. Select the User tab in the left panel.
Step 2. Select the desired memory slot(s); one or more can be selected (Select all and Select None buttons can
be used). The EDID(s) will be highlighted with yellow.
Step 3. Press the Deleted selected button to delete the EDID(s).
5.4.3. EDID Summary Window
Select an EDID from Source panel and press the Info button to display EDID summary.
Import
Delete selected
5.4.1. Sources and Destinations
The EDID memory consists of four parts:
▪
Factory EDID list (F1-F49) the pre-programmed EDIDs, see the Factory EDID List in the Appendix section.
INFO Factory EDIDs do not include HDMI support.
▪
Dynamic EDID list (D1-D2): the EDID of the last attached display device. The extender stores the last
EDID from the previously connected sink on each output port. Thus, an EDID can be shown even if
there is no device is connected to the output port at that moment.
▪
User memory locations (U1 – U49): they can be used to save custom EDIDs. Any EDID from the User/
Factory/Dynamic EDID lists can be copied to the user memory.
▪
Emulated EDID list (E1): the currently emulated EDID for the input. The source column displays the
memory location that the current EDID was routed from. The source reads the EDID from the Emulated
EDID memory on the input port.
There are two types of emulation: static and dynamic.
▪
Static EDID emulation: an EDID from the Factory or User EDID list is selected. Thus, the Emulated EDID
remains the same until the user emulates another EDID.
▪
Dynamic EDID emulation: it can be enabled by selecting D1-D2 EDID memory. The attached monitor’s
EDID is copied to the input; if a new monitor is attached to the output, the emulated EDID is changed
automatically.
INFO DVI-OPT-TX220-Pro can handle both 128 Byte EDID and 256 Byte extended EDID structures.
5.4.2. EDID Operations
Changing the Emulated EDID
Step 1. Choose the desired tab (Factory, Dynamic, or User EDID list) on the left panel and select
an EDID.
Step 2. Select the Emulated tab on the right panel.
Step 3. Select the target port on the right panel (one or more ports can be selected); the EDID(s) will be
highlighted with a yellow cursor.
Step 4. Press the Transfer button to change the emulated EDID.
Learning an EDID
The process is the same as changing the emulated EDID; the only difference is the Destination panel: press
the User button. Thus, one or more EDIDs can be copied into the user memory either from the factory memory
or from a connected sink (Dynamic).
Exporting an EDID
Source EDID can be downloaded as a file (*.bin, *.dat or *.edid) to the computer.
Step 1. Select the desired EDID from the left panel (the line will be highlighted with yellow).
Step 2. Press the Export button to open the dialog box and save the file to the computer.
Export
5. Software Control – Using Lightware Device Controller
DVI-OPT-220-Pro series – User's Manual
20
5.4.4. Editing an EDID
Select an EDID from the left panel and press the Edit button to display Advanced EDID Editor window. The
editor can read and write all descriptors, which are defined in the standards, including the additional CEA
extension. Any EDID from the device’s memory or a saved EDID file can be loaded into the editor. The software
resolves the raw EDID and displays it as readable information to the user. All descriptors can be edited, and
saved in an EDID file, or uploaded to the User memory. For more details about EDID Editor please visit our
website (www.lightware.com) and download the EDID Editor User's Manual.
EDID Editor Window
5.4.5. Creating an EDID
Since above mentioned Advanced EDID Editor needs more complex knowledge about EDID, Lightware
introduced a wizard-like interface for fast and easy EDID creation. With Easy EDID Creator it is possible to
create custom EDIDs in four simple steps. By clicking on the Create button below the left panel, Easy EDID
Creator is opened in a new window.
Easy EDID Creator Wizard
5. Software Control – Using Lightware Device Controller
DVI-OPT-220-Pro series – User's Manual
21
5.5. Settings
Basic information about the extender, such as type, serial number, installed cards’ firmware and hardware
revisions are displayed on this tab.
Device Information Tab
5.6. Log Tab
Log Tab
Download report
LDC is able to collect information from the extender and save it to a report file. This information package can
be sent to Lightware support team when a problem may arise with the extender.
INFO: When a report is necessary to generate, always let the devices be connected to the extenders, do
not disconnect them. The Controller Software will collect information about the USB devices and about
their status.
Step 1. Press the big red Download report button on the Log tab in Settings menu.
Step 2. A Save as dialog box appears. Select the place where you want to save the report file. The default file
name can be changed.
Step 3. LDC collects the needed information. This may take up to 5 minutes.
Step 4. When the process is finished, the folder is opened, where the file was saved.
The report contains the following information:
▪
Current command protocol
▪
The equipment type and serial number
▪
Firmware version of the controller
▪
Installed I/O board type and version
▪
All EDID headers and status (emulated, dynamic, factory, user)
Browse command file
The LDC is able to send a custom command file to the extender. The command file can be generated
by Lightware support. This is needed when some special commands has to be used for configuring or
troubleshooting.
INFO: This function is only for special troubleshooting cases.
5. Software Control – Using Lightware Device Controller
DVI-OPT-220-Pro series – User's Manual
22
5.7. Terminal Menu
The general-purpose of this serial terminal is intended mainly for testing and debugging purposes. All
commands can be used here that are discussed in LW2 Programmers’ Reference chapter, and can be typed
directly. The command text can be typed directly. Press Terminal button in the right bottom corner to open the
window.
Terminal Window
Commands are automatically surrounded by framing brackets as a default setting. Every sent command is
red-colored and gets a ‘>’ prefix. Received responses are blue-colored and starts with ‘<’. Commands can be
sent by pressing enter, or the Send button.
The timecode in every row shows the exact time when the command was sent or the response received.
If the Command framing checkbox is unchecked, you can send multiple commands together, however in this
case you have to type in the framing brackets manually.
If the Autoscroll checkbox is checked, the window is scrolled down automatically when a new row is added.
The window can be emptied by pressing the Clear button.
6. LW2 Programmers’ Reference
DVI-OPT-220-Pro series – User's Manual
23
6
LW2 Programmers’ Reference
Lightware DVI-OPT-220-Pro series extenders can be controlled with external
devices which can communicate according to the extender protocol. The
supported LW2 commands are described in this chapter.
Ý
LW2 Protocol Description
Ý
General LW2 Commands
Ý
EDID Management
Ý
Extender Initiated Commands
Ý
Quick Summary
6.1. LW2 Protocol Description
The device accepts commands surrounded by curly brackets - { } - and responds data surrounded by round
brackets - ( ) - only if a command was successfully executed.
6.2. General LW2 Commands
6.2.1. Query Control Protocol
Description: This command queries the active protocol for the used control interface.
INFO: The response shows only the active protocol for the interface that was used to send the command!
Format
Example
Command {P_?}
→ {P_?}
Response
CURRENT●PROTOCOL●=●#)CrLf ← (CURRENT PROTOCOL = #1)CrLf
Explanation: The extender communicates with Lightware protocol (#1).
Format Explanation
Input number in 1 or 2 digit ASCII format (01, 5, 07, 16, etc.)
Output number in 1 or 2 digit ASCII format
Input number in 2 digit ASCII format (01, 02, 10, 12 etc.)
Output number in 2 digit ASCII format (01, 02, 10, 12 etc.)
Location number in 1, 2 or 3 digit ASCII format
id number in 1 or 2 digit ASCII format
id number in 2 digit ASCII format
CrLf
Carriage return, Line feed (0x0D, 0x0A)
●
Space character (0x20)
→
Each command issued by the controller
←
Each response received from the router
6. LW2 Programmers’ Reference
DVI-OPT-220-Pro series – User's Manual
24
6.2.2. View Product Type
Description: The device responds its name.
Format
Example
Command {I}
→ {i}
Response
()CrLf
← (I: DVI-OPT-TX220-PRO)CrLf
Explanation: The connected device is a DVI-OPT-TX220-Pro.
Legend:
shows type.
6.2.3. View Serial Number
Description: The device responds its 8-digit serial number.
Format
Example
Command {s}
→ {s}
Response
(SN:)CrLf
← (SN:06342203)CrLf
INFO: Old devices may have only the last 4 numbers written onto the back of the extender.
6.2.4. View Firmware Version of the CPU
Description: View the CPU firmware revision.
Format
Example
Command {f}
→ {f}
Response
(FW:)CrLf
← (FW:1.1.8v)
Legend:
is the firmware version.
6.2.5. View Installed Board(s)
Description: Shows the hardware name and revision of the installed boards.
Format
Example
Command {is}
→ {is}
Response
(SL#●0●)CrLf
(SL●END)CrLf
←
←
(SL# 0 DVI-OPT-TX220-PRO SCH_3.2 PCB_3.2)
(SL END)
Explanation: The device reports its motherboard (slot 0).
6.2.6. View Firmware for all Controllers’
Description: Shows the firmware versions of all installed controllers.
Format
Example
Command {FC}
→ {fc}
Response
(CF●)CrLf
(CF●)CrLf
…
(CF END)CrLf
←
←
(CF DVI-OPT-TX220-PRO FW:1.1.8)
(CF END)
Explanation: The device has one control panel.
6.2.7. All Port Status
Description: Shows the actual status of all input and output ports.
Format
Example
Command {PS}
→ {ps}
Response
(PS● , )CrLf ← (PS 1,01)
Explanation: DVI signal is present on the input, display device is connected to the second output.
Legend for transmitter:
Bit values
0
1
INPUT_D
No signal
Signal detect
OUTPUT_D
No signal
Hotplug detect
Legend for receiver:
Bit values
0
1
2
INPUT_D
No signal
-
Signal detect
OUTPUT_D
No signal
Hotplug detect
-
Signal detect: Video signal is present (TMDS stream can be recognized).
Hotplug detect: Sink is connected to the output.
6. LW2 Programmers’ Reference
DVI-OPT-220-Pro series – User's Manual
25
6.3. EDID Management
6.3.1. View Emulated EDID on the Input
Description: Shows the currently emulated EDID for the input. The value at the given index shows
which EDID is used on the input.
Format
Example
Command {VEDID}
→ {VEDID}
Response
(VEDID●)CrLf
← (VEDID F33)
Explanation: F45 (Factory preset EDID #45) is emulated on the input.
Legend:
can be Fxx or Uxx or Dxx.
6.3.2. Save EDID to User Memory (Learn EDID)
Description: Learn EDID to from .
Format
Example
Command {:}
→ {U4:D2}
Response
(E_SW_OK)CrLf
(E_S_C) CrLf
← (E_SW_OK)CrLf
(E_S_C) CrLf
Explanation: EDID from output 2 is saved to user EDID #4.
Legend:
has to be Uxx.
can be Fxx or Uxx or Dxx or Exx.
INFO: If the selected user memory is not empty, the new EDID will overwrite the previous EDID.
6.3.3. Change EDID on Input
Description: Copy EDID to the input port from memory location .
Format
Example
Command {:}
→ {E1:F10}
Response
(E_SW_OK)CrLf
…delay…
(E_S_C) CrLf
←
←
(E_SW_OK)CrLf
…delay…
(E_S_C) CrLf
Explanation: Factory EDID #10 is emulated on input 1.
Legend:
has to be Exx.
can be Fxx or Uxx or Dxx.
Location
EDID type
Description
EA
That is valid to all inputs, but since the transmitter has one input, the
result will be the same as typing E1.
Fxx or Uxx
Static EDID routing occurs. In this case the extender will keep the same
EDID on the input until it is changed with another command.
Dxx
Dynamic EDID routing occurs. In this case the extender will follow the
EDID changes on the output. Every time a different EDID is recognized on
the output, it is copied instantly to the input.
INFO: The extender sends (E_S_C) only if the new EDID is different from the earlier one.
6.3.4. Watch EDID Validity Table
Description: Shows EDID validity table, which contains information about the EDID memory states.
Format
Example
Command {WV}
→ {WV*}
Response
(EV● )CrLf
← (EVU 1100000000000000000000000
0000000000000000000000000)CrLf
← (EVD 01) CrLf
← (EVE 3) CrLf
Explanation: First and second locations contain valid EDID in the user memory. The second dynamic location
and the input contain valid EDID.
Legend:
Result
Response length
F
Factory preset EDIDs
49
U
User saved EDIDs
49
D
Dynamic EDIDs
2
E
Emulated EDIDs
1
*
U, D and E EDIDs
Each number represents the EDID validity state for the corresponding memory location:
Value
Description
0
invalid EDID
1
valid EDID
3
changed EDID
4
deleted EDID
INFO: If a changed EDID is queried by the {WH} command (see the next section), its value returns to 1. The
status of a deleted EDID returns to 0 after query.
6. LW2 Programmers’ Reference
DVI-OPT-220-Pro series – User's Manual
26
6.3.5. View EDID Header
Description: Shows basic information about EDIDs in the memory.
Format
Example
Command {WH}
→ {WHD2}
Response
(EH# ● )CrLf ← (EH#D2 NEC [email protected] 24WMGX3)CrLf
Explanation: Shows the EDID from location D2.
Legend:
Depending on the query can be for one EDID, all EDID in the block.
Result
Response
Fxx
Factory EDID query
header for one EDID
Uxx
User EDID query
Dxx
Dynamic EDID query
Exx
Emulated EDID query
F*
All Factory preset EDIDs
headers for all Factory EDIDs
U*
All User saved EDIDs
headers for 49 user EDIDs
D*
All Dynamic EDIDs
headers from all outputs
E*
All Emulated EDIDs
headers from all inputs
consists of 3 fields separated by spaces:
PNPID code
Preferred resolution
Name
The three letter abbreviation of
the manufacturer.
The resolution and refresh rate
stored in the preferred detailed
timing block.
The name of display device
stored in product descriptor.
The is “-“ for invalid EDIDs.
6.3.6. Download EDID Content from a Location
Description: EDID hex bytes can be read directly. The extender will issue the whole content of the EDID
present on memory location (256 bytes).
Format
Example
Command {WE}
→ {WEF1>}
Response
(EB#●●●.. ● CrLf
← (EB#F1 00 FF FF FF FF FF FF 00 32 F2 00 00
00 .. .. .. 00 00) CrLf
Legend:
.. are space separated hex characters represented in ASCII format.
Explanation: Full EDID from memory location F1 is downloaded.
6.3.7. Upload EDID Content to a Location
Description: EDID hex bytes can be written directly to the user programmable memory locations.
Sequence
Step 1. Prepare the extender to accept EDID bytes to the specified location with command {WL#}
Step 2. Extender responds that it is ready to accept EDID bytes with (E_L_S)CrLf
Step 3. Send 1 block of EDID (1 block consist of 8 bytes of hex data represented in ASCII format) with
command {WB#●●●●●● ●●}
Step 4. The extender acknowledges with response (EL#)
Step 5. Repeat steps 3 and 4 to send the remaining 31 blocks of EDID (32 altogether)
Step 6. After the last acknowledge, the extender indicates that the EDID status changed by sending (E_S_C) CrLf
Format
Example
Command {WL#}
→ {WL#U3}
Response
(E_L_S)CrLf
← (E_L_S) CrLf
Command {WB#1●●●
●●●● ●}
→ {WB#1 00 FF FF FF FF FF FF 00}
Response
(EL#)CrLf
← (EL#1) CrLf
Command {WB#2●●
●●●
●●●}
→ {WB#2 38 A3 8E 66 01 01 01 01}
Response
(EL#) CrLf
← (EL#2) CrLf
…
…
Command {WB#32●●
●●●
●●●}
→ {WB#32 36 59 42 0A 20 20 00 96}
Response
(EL#) CrLf
← (EL#32) CrLf
Response
(E_S_C) CrLf
← (E_S_C) CrLf
Legend:
represents the sequential number of every 8 byte part of EDID. It is between 1 and 32.
.. are the bytes of EDID.
Explanation: Full EDID uploaded to memory location U3.
INFO: The uploaded EDID content is checked and saved only if it is a valid EDID.
6. LW2 Programmers’ Reference
DVI-OPT-220-Pro series – User's Manual
27
6.3.8. Delete EDID from Memory
Description: Clear EDID from memory location .
Format
Example
Command {DE}
→ {DEU*}
Response
(DE_OK)CrLf
(E_S_C)CrLf
← (DE_OK)CrLf
(E_S_C)CrLf
Explanation: All user EDIDs are cleared from memory.
Legend: Depending on , one EDID, or all EDIDs in a block can be cleared.
Result
Fxx
Not valid! Factory EDID cannot be deleted.
Uxx
Specified User EDID is deleted.
Dxx
Specified Dynamic EDID is deleted. It will be empty until a new monitor is connected.
Exx
Not valid! The EDID of the only one input cannot be deleted.
F*
Not valid! Factory EDID cannot be deleted.
U*
All User EDIDs are deleted.
D*
All Dynamic EDIDs are deleted. They will be empty until a new monitor is connected.
E*
Not valid! The EDID of the only one input cannot be deleted.
INFO: If not valid EDID is tried to delete, the response will be “ERR03”.
6.3.9. Restart the Extender
Description: The transmitter can be restarted without unplugging power.
Format
Example
Command {RST}
→ {RST}
Response
-
← Booting commands run…
Explanation: The extender reboots and executes the booting commands.
6.4. Extender Initiated Commands
6.4.1. EDID Status Changed (Transmitter)
Description: This is sent after any command which changed the EDID table (EDID copy, EDID switch), or after
a new EDID source e.g. a new display device is connected to the extender.
Format
Example
Command various
→ a new monitor is connected to an output
Response
(E_S_C) CrLf
← (E_S_C) CrLf
Explanation: When a new monitor is connected to an output port, its EDID is read. The message from the
extender shows that an EDID has changed.
INFO: The extender stores the last attached display device’s EDID connected to the local monitor output.
After disconnecting this device its EDID is still present at the extender’s memory, therefore no status
change message is issued by the device if a display device having the same EDID is connected to that
output. (The same display device is connected again).
INFO: To keep your application in sync with the extender it is recommended to issue a watch validity
( {wvd}, {wvu}, {wve} ) commands after receiving an EDID status changed response, and read all location
indicating “3” or “4” in the table, as the change of these EDIDs triggered the (E_S_C) message.
6.4.2. Port Status Changed
Description: This message is sent when any value changes in the response for the {PS} command. The
message means that an input or output port’s state has changed e.g. a source or display device is connected
or disconnected.
Format
Example
Command none
→ an input port looses signal
Response
(PSC) CrLf
← (PSC)CrLf
Explanation: An input port (which had signal present before) detects no signal. The extender sends a
message to indicate port status change.
INFO: The (PSC) message can be omitted by third party controller, or it can be used to trigger a {PS}
command. In the latter case, the controller can be up to date with the port status without continuous
queries.
Description: The device responds its 8-digit serial number.
INFO: Old devices may have only the last 4 numbers written onto the back of the extender.
6. LW2 Programmers’ Reference
DVI-OPT-220-Pro series – User's Manual
28
6.5. Quick Summary
General LW2 Commands
Operation
See in
section
Command
Query Control Protocol
6.2.1
{P_?}
View Product Type
6.2.2
{i}
View Serial Number
6.2.3
{s}
View Firmware Version of the CPU
6.2.4
{f}
View Installed Board(s)
6.2.5
{is}
View Firmware for all Controllers’
6.2.6
{fc}
All Port Status
6.2.7
{ps}
EDID Management
Operation
See in
section
Command
View Emulated EDID on the Input
6.3.1
{VEDID}
Save EDID to User Memory (Learn EDID)
6.3.2
{:}
Change EDID on Input
6.3.3
{:}
Watch EDID Validity Table
6.3.4
{WV*}
View EDID Header
6.3.5
{WHD2}
Download EDID Content from a Location
6.3.6
{WEF1>}
Upload EDID Content to a Location
6.3.7
{WL#}
Delete EDID from Memory
6.3.8
{DE}
Restart the Extender
6.3.9
{RST}
Extender Initiated Commands
Operation
See in
section
Command
EDID Status Changed (Transmitter)
6.4.1
various - a new monitor is connected to an output
Port Status Changed
6.4.2
none - an input port looses signal
7. Firmware Upgrade
DVI-OPT-220-Pro series – User's Manual
29
7
Firmware Upgrade
This chapter is meant to help customers perform firmware upgrades on our
products with Lightware Bootloader software. To get the latest software and
firmware pack , please contact [email protected].
Ý
Short Instructions
Ý
Install the Bootloader
Ý
Detailed Instructions
DVI-OPT-TX220-Pro and DVI-OPT-RX220-Pro can be upgraded using
Lightware Bootloader from a Windows based PC or Laptop through
RS-232 connection.
ATTENTION! The firmware upgrade will delete the EDID’s from
the user memory. If you need the EDID(s) from the user memory,
first save as a file, then load it after firmware upgrade. See section
EDID Operations for more information about saving and loading
processes.
Setting or parameter
After firmware upgrade
Serial number
Remain unchanged
I/O port and preset names
Remain unchanged
EDID lists (F, U, D)
User EDIDs are deleted
EDID emulation table (E)
F49 will be set on the input
Input port settings
Set to factory defaults
Output port settings
Set to factory defaults
7.1. Short Instructions
Step 1. Get the firmware pack and the Lightware Bootloader application.
Step 2. Install the Lightware Bootloader application.
Step 3. Establish the connection between the computer and the
device(s).
Step 4. Start the Lightware Bootloader and follow the instructions.
7.2. Install the Bootloader
Step 1. Run Installer_LW_bootloader_v3_2_9.exe (3_2_9 means the
3-digit software version of the Bootloader).
Step 2. Select destination folder and click on Install button (using the
default path is highly recommended).
Step 3. To create a desktop icon click on Yes button in the pop-up
window.
Step 4. After the message Installation was successful, please click on the
Close button to finish the process.
7.3. Detailed Instructions
7.3.1. Establish the Connection between the Computer and the Device
Connect the appliance and the computer via RS-232 port with standard
Male to Female cable (straight through).
7.3.2. Start the Bootloader Software and Follow the Instructions
Step 1. Run Lightware Bootloader as an
administrator.
Step 2. Click FIND Button!
Step 3. Select the desired device. Double click on the desired COM
port.
7. Firmware Upgrade
DVI-OPT-220-Pro series – User's Manual
30
When the connection is established,
the
device
is
switched
to
Bootload-mode and the display
shows Firmware upgrade in progress…
(if the extender is switched off and on again, the display will be empty).
ATTENTION! The extender cannot be switched back manually
to normal operation mode, it will be done automatically after
successful firmware upgrade. Do not interrupt the upgrade, let the
software finish the process.
If you wish to connect, click YES to establish connection with the
extender. It will take 10-15 seconds to get all information.
INFO: The bootloader application will restart the extender when it
establishes the connection. All connected DVI source and monitors
will act as if the extender was powered down.
Step 4. Review the firmware versions
After the connection is made, the device properties, and the installed
controller modules are displayed. Select the controller type that needs
firmware upgrade by clicking the checkbox next to it.
Step 5. Browse for the new firmware(s).
Click the corresponding cell in the Browse New Firmware column.
A dialog pops up, to confirm if you really want to modify the path. Now
you can browse for the new firmware file to upload. After opening the
new file, the new firmware field will contain the name of the firmware
file.
Step 6. Upgrade firmware(s)
Click UPGRADE SELECTED FIRMWARES button on the left side. A
confirmation message appears.
After clicking the YES button the selected controller is being
reprogrammed, with the firmware you selected. If you select a file
that doesn’t fit for the selected controller, you will get an information
message about which file is wrong. If you selected a controller to
upgrade, but you had not selected a file for it, then you will also get an
information message about which file is missing.
Quick Bootload mode can be switched on or off any time. It makes
the bootloader software faster by only checking the checksum of the
controller. No data verification is done after writing if the checksum
was correct.
INFO: The reprogramming can take between 3-8 minutes.
A progress bar will show the current state of the reprogramming. With
some controller type an erasing process will take place first, and then
the programming is done, so the progress bar runs up twice.
When the reprogramming is finished, a Done! message will appear in
the bottom left corner. The application closes the connection, and the
extender restarts.
Firmware upgrade
in progress...
Step 7. Done!
If the upgrade was successful, the following window pops up:
Now you can close the application, or you can select another device
to upgrade.
After closing the bootloader application, switch the upgraded device
off and then on. Now the device is ready to be used with the new
firmware!
INFO: Please note that after firmware upgrade F49 (Universal EDID)
will be set as emulated EDID on the input.
DVI-OPT-220-Pro series – User's Manual
31
8
Troubleshooting
Usually, if the system seems not to transport the signal as expected, the best
strategy for troubleshooting is to check signal integrity through the whole
signal chain starting from source side and moving forward to receiver end.
Link to connections/cabling section.
Link to front panel operation section.
Link to LDC software section.
LW2
Link to LW2 protocol commands section
At first, check front panel LEDs and take the necessary steps according to their states. For more information
about status, LEDs refer to the Front View and Rear View sections.
Symptom
Root cause
Action
Refer to
Video signal
No picture
on the video
output
Device(s) not
powered
properly.
Check the extenders and the other devices if they are
properly powered; try to unplug and reconnect them.
3.3
Cable connection
problem.
Due to the high data rates cables must fit very well,
check all the connectors. If your source or display has
more connectors then make sure that the proper port
is selected.
3.3
Cable quality
problem.
Due to the high data rates, high quality cables must
be used. It is recommended to use OM3 or OM4 fiber
cables.
10.3
Endface surface
of the fiber optical
cable became
contaminated.
Use special fiber optical cable cleaning equipment to
clean it carefully.
Display is not
capable of receiving
the sent video
format.
Try emulating your display device’s EDID to the source.
4.2.4
5.4
LW2
6.3.3
Source power and
configuration
problems.
Check the Source Connected LED on the front side of
the transmitter. This LED indicates the presence of the
+5V signal coming from the DVI source, which means
the DVI source device is powered on and the cable link
is well connected. If it is not illuminated, then your DVI
source is either powered off or not working properly.
The HDMI output can be turned off on most DVD
players. Please refer to the user’s manual of your DVI
source. The other option is that the cable is damaged,
test the system it with another one.
If the source is a computer, then verify that the DVI
output is selected and active. Try restarting your
computer; if you only get a picture during the booting
process, you have to review the driver settings.
DVI-OPT-220-Pro series – User's Manual
32
How to Speed up the Troubleshooting Process?
Lightware’s
technical
support
team
is always working hard to provide the
fastest support possible. Our team’s
response time is one of the best in the
industry and in the toughest of cases we
can directly consult with the hardware
or software engineer who designed the
product to get the information from the
most reliable source.
However, the troubleshooting process can be even faster… with your help.
There are certain pieces of information that push us in the right direction to finding the root cause of the
problem. If we receive most of this information in the first e-mail or it is gathered at the time when you call
us, then there is a pretty high chance that we will be able to respond with the final solution right away.
This information is the following:
▪
Schematic (a pdf version is preferred, but a hand drawing is sufficient).
▪
Serial number(s) of the device(s) (it is either printed somewhere on the box or you can query it in the
Device Controller software or on the built-in website).
▪
Firmware versions of the devices (please note that there may be multiple CPUs or controllers in the
device and we need to know all of their firmware versions, a screenshot is the best option).
▪
Cable lengths and types (in our experience, it’s usually the cable).
▪
Patch panels, gender changers or anything else in the signal path that can affect the transmission.
▪
Signal type (resolution, refresh rate, color space, deep color).
▪
Emulated EDID(s) (please save them as file and send them to us).
▪
Actions to take in order to re-create the problem (if we cannot reproduce the problem, it is hard for us
to find the cause).
▪
Photo or video about the problem (‘image noise’ can mean many different things, it’s better if we see
it too).
▪
Error logs and backup files from the Lightware Device Controller software.
The more of the above information you can give us the better. Please send these information to the Lightware
Support Team to speed up the troubleshooting process.
POWER
SOURCE CONNECTED (pin14 +5V)
LASER ACTIVE
DVI INPUT SIGNAL PRESENT
ENTER
DVI Multimode Fiber Transmitter
DVI-OPT-TX220-Pro
DVI-OPT-220-Pro series – User's Manual
33
9
Technologies
The following sections contain descriptions and useful technical information
how the devices work in the background. The content is based on experiences
and cases we met in the practice. These sections help to understand features
and technical standards like the followings:
Ý
EDID Management
Ý
Pixel Accurate Reclocking
Ý
Serial Management
9.1. EDID Management
9.1.1. Understanding the EDID
The Extended Display Identification Data (EDID) is the passport of
display devices (monitors, TV sets, projectors). It contains information
about the capabilities of the display, such as supported resolutions,
refresh rates (these are called Detailed Timings), the type and
manufacturer of the display device, etc.
After connecting a source to a display (DVI, HDMI, DP), the source
reads out the EDID to determine the resolution and refresh rate of the
image to be transmitted.
Who are
you?
I am a monitor.
Here is my EDID.
Now I know what
I can send.
EDID Communication
Most DVI computer displays have 128-byte long EDID structure.
However, Digital Televisions and HDMI capable displays may have
another 128 bytes, which is called E-EDID and defined by CEA
(Consumer Electronics Association). This extension contains
information about additional Detailed Timings, audio capabilities,
speaker allocation and HDMI capabilities. It is important to know that
all HDMI capable devices must have CEA extension, but not all devices
with CEA extension are HDMI capable.
Common Problems Related to EDID
Problem:
“My system consists of the following: a computer, a
Lightware device, a WUXGA (1920x1200) LCD monitor,
and an SXGA (1280x1024) projector. I would like to see
the same image on the monitor and the projector. What
EDID should I choose on the Lightware device?”
Solution:
If you want to see the image on both displays, you need
to select the resolution of the smaller display (in this
case SXGA), otherwise the smaller display may not show
the higher resolution image.
Problem:
“I have changed to a different EDID on an input port of
the Lightware device to have a different resolution but
nothing happens.”
Solution:
Some graphics cards and video sources read out the
EDID only after power-up and later they do not sense that
EDID has been changed. You need to restart your source
to make it read out the EDID again.
9.1.2. Advanced EDID Management
Each DVI sink (e.g. monitors, projectors, plasma displays, etc...) must
support the EDID data structure. Source BIOS and operating systems
are likely to query the sink using DDC2B protocol to determine what
pixel formats and interface are supported. DVI standard uses EDID
data structure to identify the monitor type and capabilities. Most DVI
sources (VGA cards, set top boxes, etc.) will output DVI signal after
accepting the connected sink’s EDID information. In the case of EDID
readout failure or missing EDID, the source will not output DVI video
signal.
Lightware devices provide the Advanced EDID Management function
that helps system integration. The built-in EDID Router can store and
emulate factory pre-programmed- and User programmable EDIDs. The
EDID of the attached monitors or projectors for each output are stored
in a non-volatile memory. This way the EDID of a monitor is available
when the monitor is unplugged or switched off.
Any EDID can be emulated on any input. An emulated EDID can be
copied from the EDID router’s memory (static EDID emulation), or
from the last attached monitor’s memory (dynamic EDID emulation).
For example, the Lightware device can be set up to emulate a sink
device, which is connected to one of the outputs. In this case, the EDID
automatically changes, if the monitor is replaced with another display
device (as long as it has a valid EDID).
EDID is independently programmable for all inputs without affecting
each other. All inputs have their own EDID circuit.
INFO: The user is not required to disconnect the video cable to
change an EDID as opposed to other manufacturer’s products.
EDID can be changed even if a source is connected to the input and
powered ON.
INFO: When EDID has been changed, the router toggles the
HOTPLUG signal for 2 seconds. Some sources do not sense this
signal. In such cases, the source device must be restarted or
powered OFF and ON again.
DVI-OPT-220-Pro series – User's Manual
34
9.2. Pixel Accurate Reclocking
Signal reclocking is an essential important procedure in digital signal
transmission. After passing the reclocking circuit, the signal becomes
stable, jitter-free, and can be transmitted over more equipment like
processors, or event controllers. Without reclocking, sparkles, noise,
and jaggies appear on the image.
Lightware’s sophisticated Pixel Accurate Reclocking technology
fixes more problems than general TMDS reclocking. It removes not
only intra-pair skew but inter-pair skew as well. The Pixel Accurate
Reclocking circuit eliminates the following errors:
Intra-pair skew
Skew between the + and - wires within a differential wire pair (e.g.
Data2- and Data2+). It’s caused by different wire lengths or slightly
different wire construction (impedance mismatch) in DVI cable. It
results in jitter.
Intra-pair skew
+
-
Inter-pair skew
Skew between two differential wire pairs in a cable. It is caused by
different wire pair lengths or different number of twists in the DVI
cable. Too much inter-pair skew results color shift in the picture or
sync loss.
+
-
Inter-pair skew
+
-
Jitter
Signal instability in the time domain. The time difference between two
signal transitions should be a fixed value, but noise and other effects
cause variations.
Jitter
+
-
Noise
Electromagnetic interference between other electronic devices such
as mobile phones, motors, etc. and the DVI cable are coupled onto the
signal. Too much noise results in increased jitter.
Noise
+
-
DVI-OPT-220-Pro series – User's Manual
35
9.3. Serial Management
9.3.1. General Information
There are two types of devices in general serial communication:
▪
Data Terminal Equipment: Data Terminal Equipment (DTE) is an end instrument that converts user
information into signals or reconverts received signals. Typical DTE devices: computers, LCD touch
panels and control systems.
▪
Data Circuit-terminating Equipment: Data Circuit-terminating Equipment (DCE) is a device that sits
between the DTE and a data transmission circuit. It is also called data communication equipment and
data carrier equipment. Typical DCE devices: projectors, industrial monitors and amplifiers.
Among others the pin assignment is different between DTE and DCE.
DTE
DCE
Pin 2:
RD
TD
Pin 3:
TD
RD
RD: Received Data (digital input)
TD: Transmitted Data (digital output)
Different type of serial cables must be used between different serial devices.
DTE
DCE
DTE
Null-modem
Straight
DCE
Straight
Null-modem*
* In general contact DCE with DCE by tail-circuit serial cable.
9.3.2. Types of Serial Cables
Straight Serial Cable
Null-modem Serial Cable
Straight pin-outs both ends.
Straight pin-out at the one end and cross
pin-out at the other end (interchange lines
of TX and RX).
Serial cables between devices may have male or female plugs and their type may be straight or null-modem
in usual.
ATTENTION! The cable type does not depend on the plug type.
9.3.3. RS-232 Signal Transmission over Lightware Extender Devices
The following examples describe the detailed integration of Lightware devices between different RS-232 pin
assignment units.
INFO: DVI-OPT-220-Pro series extenders are DCE units (according to their pinouts) with female plugs.
Extending RS-232 between DTE and DCE Third-party Devices
Connect straight serial cable between controller system (DTE) and the transmitter (DCE) and null-modem
serial cable between receiver (DCE) and projector (DCE).
RS-232 Connection Example between a Controller System and a Projector
Extending RS-232 between DTE and DTE Third-party Devices
Connect straight serial cable between controller system (DTE) and the transmitter (DTE) and straight serial
serial cable between receiver (DTE) and computer (DTE).
RS-232 Connection Example between Two Computers
Transmitter
Controller system
Projector
Female - Male
Male - Male
Transmission
interface
Straight serial
cable
Null-modem
serial cable
DCE
Pin 2: RD
Pin 3: TD
Receiver
DCE
Pin 2: TD
Pin 3: RD
Pin 2: TD
Pin 3: RD
DTE
DCE
Pin 2: TD
Pin 3: RD
POWER
SOURCE CONNECTED (pin14 +5V)
LASER ACTIVE
DVI INPUT SIGNAL PRESENT
ENTER
DVI Multimode Fiber Transmitter
DVI-OPT-TX220-Pro
DVI Multimode Fiber Receiver
DVI-OPT-RX220-ST-Pro
MONITOR 2 HOTPLUG
DVI SIGNAL PRESENT
MONITOR 1 HOTPLUG
GREEN: LASER DETECTED
RED BLINKING: LOW LASER LEVEL
POWER
Transmitter
Computer
Computer
Female - Male
Male - Female
Transmission
interface
DCE
Pin 2: RD
Pin 3: TD
Receiver
DCE
DTE
DTE
Pin 2: RD
Pin 3: TD
Pin 2: TD
Pin 3: RD
Pin 2: TD
Pin 3: RD
Straight serial
cable
Straight serial
cable
POWER
SOURCE CONNECTED (pin14 +5V)
LASER ACTIVE
DVI INPUT SIGNAL PRESENT
ENTER
DVI Multimode Fiber Transmitter
DVI-OPT-TX220-Pro
DVI Multimode Fiber Receiver
DVI-OPT-RX220-ST-Pro
MONITOR 2 HOTPLUG
DVI SIGNAL PRESENT
MONITOR 1 HOTPLUG
GREEN: LASER DETECTED
RED BLINKING: LOW LASER LEVEL
POWER
DVI-OPT-220-Pro series – User's Manual
36
10
Appendix
Ý
Specification
Ý
Factory EDID List
Ý
Maximum Extension Distances
Ý
Mechanical Drawings
10.1. Specification
General
Compliance ......................................................................................... CE
EMI/EMC compliance ....................... EN 55035:2017, EN 55032:2015
Safety ........................................................................... EN 60065 Class I
Cooling.........................................................................................Passive
Operating temperature ............................... 0 to +55˚C (+32 to +122˚F)
Storage temperature ................................. -40 to +85˚C (-40 to +185˚F)
Operating humidity ..................................10% to 90%, non-condensing
Warranty .......................................................................................3 years
Power
Power source.................................................... 100-240V AC, 50/60Hz
Power supply ............................................................................... Internal
Power consumption: (TX220) ......................................................3.5 W*
Power consumption: (RX220) .........................................................4 W*
* Self-consumption; remote powering not included
Enclosure
Rack mountable .................................................................................Yes
Mounting ........................................... 1U high half rack shelf (optional)
..........................................................................Double UD-kit (optional)
................................................................... Mounting bracket (optional)
Material .................................................................................. 1 mm steel
Dimensions in mm (excluding connectors) ...........................................
......................................................................221W x 181D x 42.2H mm
Net Weight (TX220-Pro) ..............................................1420 g / product
Net Weight (RX220-Pro) ..............................................1340 g / product
Net Weight (TX220-ST-Pro) .........................................1400 g / product
Net Weight (RX220-ST-Pro) .........................................1320 g / product
Control Ports
Serial port .....................................................................................RS-232
Direction .............................................................................Bi-directional
Baud rate ......................................................................................... 9600
Optical Port
Fiber type .................................................... 50/125 SC Multimode fiber
Laser wavelengths ........................4ch. CWDM: 778; 800; 825; 850 nm
Laser class specification .......................................................... Class 3R
Transmitter output OMA* .................................-6.25 dBm (worst case)
Receiver OMA* sensitivity ..............................-14.25 dBm (worst case)
Optical loss budget .................................................8 dBm (worst case)
Transmission distance .............. 2500 meters (using OM3e type fiber)
*OMA: Optical Modulation Amplitude
Digital video signal
Standard .......................................................................................DVI 1.0
Color depth .............................................. maximum 24 bits, 8 bit/color
Color Format .....................................................................................RGB
Colorspace conversion ....................................................................... No
Maximum data rates .............. 4.95 Gbps (1.65 Gbps /TMDS channel)
Video delay ..................................................................................0 frame
Resolutions...............................................from 640x480 to 1920x1200
Reclocking (RX220) ..................................... Pixel Accurate Reclocking
EDID emulation (TX220) ................. yes, Advanced EDID Management
EDID memory (TX220) .yes, 50 factory preset, 49 user programmable
EDID support (TX220) ..............................256 byte extended EDID v1.3
HDCP compliant.................................................................................. No
Connectors / ESD protection (HBM EIA/JESD22-A114F)
DVI input/output..................................... 29-pole DVI-I digital only/8 kV
Optical fiber input/output (-Pro) ..............................................................
.................................................Neutrik NO2-4FDW type LC duplex/n.a.
.................................................LC simplex for B channel breakout/n.a.
Optical fiber input/output (-ST-Pro) ..........................ST connector/n.a.
RS-232 port ...................................DE-9F (9-pole D-sub Female)/15 kV
Alarm (only on receiver) ........ 3 pole Phoenix® Combicon, series/2 kV
Power connector ......................................Standard IEC receptacle/n.a.
DVI-OPT-220-Pro series – User's Manual
37
10.2. Factory EDID List
Mem.
Resolution
F1
640 x
480
@ 60.0
Hz
F2
640 x
480
@ 75.0
Hz
F3
848 x
480
@ 60.0
Hz
F4
800 x
600
@ 50.0
Hz
F5
800 x
600
@ 60.30
Hz
F6
800 x
600
@ 74.99
Hz
F7
1024 x
768
@ 49.98
Hz
F8
1024 x
768
@ 60.0
Hz
F9
1024 x
768
@ 75.2
Hz
F10
1152 x
864
@ 75.0
Hz
F11
1280 x
768
@ 50.0
Hz
F12
1280 x
768
@ 59.92
Hz
F13
1280 x
768
@ 75.0
Hz
F14
1360 x
768
@ 60.1
Hz
F15
1364 x
768
@ 50.0
Hz
F16
1364 x
768
@ 59.93
Hz
F17
1364 x
768
@ 74.98
Hz
F18
1280 x
1024
@ 50.0
Hz
F19
1280 x
1024
@ 60.1
Hz
F20
1280 x
1024
@ 75.1
Hz
F21
1366 x
1024
@ 59.99
Hz
F22
1400 x
1050
@ 49.99
Hz
F23
1400 x
1050
@ 59.99
Hz
F24
1400 x
1050
@ 75.0
Hz
F25
1680 x
1050
@ 59.99
Hz
F26
1600 x
1200
@ 50.0
Hz
F27
1600 x
1200
@ 60.0
Hz
F28
1920 x
1200
@ 59.55
Hz
F29
1920 x
1200
@ 50.0
Hz
F30
1440 x
480i
@ 60.3
Hz
Mem.
Resolution
F31
640 x
480
@ 59.94
Hz
F32
720 x
480
@ 59.92
Hz
F33
1440 x
576i
@ 50.6
Hz
F34
720 x
576p
@ 50.0
Hz
F35
1280 x
720p
@ 50.0
Hz
F36
1280 x
720p
@ 60.0
Hz
F37
1920 x
1080i
@ 50.3
Hz
F38
1920 x
1080i
@ 50.0
Hz
F39
1920 x
1080i
@ 60.5
Hz
F40
1920 x
1080
@ 24.0
Hz
F41
1920 x
1080
@ 24.99
Hz
F42
1920 x
1080
@ 30.0
Hz
F43
1920 x
1080
@ 50.0
Hz
F44
1920 x
1080
@ 49.99
Hz
F45
1920 x
1080
@ 60.0
Hz
F46
2048 x
1080
@ 49.99
Hz
F47
2048 x
1080
@ 50.0
Hz
F48
2048 x
1080
@ 59.99
Hz
F49
1920 x
1200
@ 59.55
Hz
INFO: Factory EDIDs do not include HDMI support.
10.3. Maximum Extension Distances
The below table shows the transmission distances via optical cable
between the DVI-OPT-220-Pro series extenders depending on the
cable quality and pixel clock frequency
Resolution,
pixel clock rate
OM1
(62.5/125)
OM2
(50/125)
OM3
(50/125)
OM4
(50/125)
1080p@60Hz 24 bpp Not supported
600 m
1200 m
2500 m
10.4. Factory Default Settings
Parameter
Setting/Value
RS-232 settings
9600 Baud, 8 data bit, 1 stop bit, no parity
Emulated EDID
F49 (1920x120059.55Hz Universal EDID)
Laser enabled
Yes
DVI-OPT-220-Pro series – User's Manual
38
10.5. Mechanical Drawings
INFO: DVI-OPT-TX220-pro can be seen on the pictures; the external dimensions and the fixing holes of all
units are the same.
Front View
Rear View
Top View
POWER
SOURCE CONNECTED (pin14 +5V)
LASER ACTIVE
DVI INPUT SIGNAL PRESENT
ENTER
DVI Multimode Fiber Transmitter
DVI-OPT-TX220-Pro
42.2
221
A
B
DVI INPUT
LOCAL MONITOR OUTPUT
100-240 V AC
FUSE: F 1 A
50/60 Hz 0.7 A
Remote power for receiver DC OUT +15V
GND
Remote power for receiver DC OUT +15V
GND
LASER
ACTIVE
FIBER OUTPUT (A):
50/125 MULTIMODE
RoHS
Made in EU, HU
B
A
LOCAL CONTROL
RS-232
Laser Radiation
850 nm, Class 3
181
Left View
Bottom View
17
15
40
75
M3 thread
M3 thread
M3 thread
178.5
M3 thread
M3 thread
21.7
93
DVI-OPT-220-Pro series – User's Manual
39
10.6. Further Information
Limited Warranty Statement
1. Lightware Visual Engineering LLC (Lightware) warrants to all trade
and end user customers that any Lightware product purchased will be
free from manufacturing defects in both material and workmanship
for three (3) years from purchase unless stated otherwise below. The
warranty period will begin on the latest possible date where proof of
purchase/delivery can be provided by the customer. In the event that
no proof can be provided (empty ‘Date of purchase’ field or a copy of
invoice), the warranty period will begin from the point of delivery from
Lightware.
1.1. 25G and MODEX product series will be subject to a seven (7) year
warranty period under the same terms as outlined in this document.
1.2. If during the first three (3) months of purchase, the customer is
unhappy with any aspect of a Lightware product, Lightware will accept
a return for full credit.
1.3. Any product that fails in the first six (6) months of the warranty
period will automatically be eligible for replacement and advanced
replacement where available. Any replacements provided will be
warranted for the remainder of the original unit’s warranty period.
1.4. Product failures from six (6) months to the end of the warranty
period will either be repaired or replaced at the discretion of Lightware.
If Lightware chooses to replace the product then the replacement will
be warranted for the remainder of the original unit’s warranty period.
2. The above-stated warranty and procedures will not apply to any
product that has been:
2.1. Modified, repaired or altered by anyone other than a certified
Lightware engineer unless expressly agreed beforehand.
2.2. Used in any application other than that for which it was intended.
2.3. Subjected to any mechanical or electrical abuse or accidental
damage.
2.4. Any costs incurred for repair/replacement of goods that fall into
the above categories (2.1., 2.2., 2.3.) will be borne by the customer at
a pre-agreed figure.
3. All products to be returned to Lightware require a return material
authorization number (RMA) prior to shipment and this number must
be clearly marked on the box. If an RMA number is not obtained or is
not clearly marked on the box, Lightware will refuse the shipment.
3.1. The customer will be responsible for in-bound and Lightware will
be responsible for out-bound shipping costs.
3.2. Newly repaired or replaced products will be warranted to the end
of the originally purchased products warranty period.
Document Revision History
Rev.
Release
date
Changes
Editor
1.0
11-12-2014 Initial version
Laszlo
Zsedenyi
1.1
15-12-2015 Safety instructions updated, CE
page pulled out
Laszlo
Zsedenyi
1.2
14-06-2017
New chapters: Port diagrams, Two
video signals through one Neutrik
OpticalCON Duo hybrid cable
Judit
Barsony
2.0
22-06-2018 New format introduced, minor
corrections
Judit
Barsony
Contact Us
[email protected]
+36 1 255 3800
[email protected]
+36 1 255 3810
Lightware Visual Engineering LLC.
Peterdy 15, Budapest H-1071, Hungary
www.lightware.com
©2018 Lightware Visual Engineering. All rights reserved. All