ABB 4680 Installation & Operating Manual

Brand: ABB
Category: Transmitter
Model: 4680 (Installation & Operating Manual)
File Type: PDF
File Size: —
Pages: 20
Text of ABB 4680 Installation & Operating Manual

Installation & Operating

Guide Models 4680 & 4685 EXFG Oxygen Transmitters 4600 4600 A1 A2 % Oxygen 20.9 % Oxygen 25.0 A1 A2

ABB 4680 We are an established world force in the design and manufacture of instrumentation for industrial

process control, flow measurement, gas and liquid analysis and environmental applications. As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide. We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support. T

ABB 4680 Controls & Displays

Operation Programming I I I I I I Part No. IM/EXFG–4600 INTERFACE UNIT Certification Product Identification Mechanical Installation Electrical Installation Calibration Fault Finding I I I I I I Part No. IM/EXFG–INT PROBE I I I I I I I Part No. IM/EXFG–PB SPECIFICATION SHEET Full Specification I Part No. SS/EXFG Certification Product Identification

NON HAZARDOUS AREA

HAZARDOUS AREA (Zone 1, Class IIB) Process 20°C to 600°C 1.1 Bar Absolute Maximum (40in WG) EXFG Probe EEx d IIB T3 (Tamb –20°C to 55°C) to EN30014 1993 and EN30018 1995 Mains Supply Control Thermocouple Signal 4 to 20mA Output Signal (25% to 0.25% O2) or 4680 Transmitter Mains Supply Flameproof Interface Electronics Unit EEx d IIB T6 Conforming to BS5501 Part 5: 1977 Flue 4685 Transmitter Retransmission Output – see Sectio

out of case

(Panel-mounted Model) 4685/500 Undo captive screw Remove Plug (if fitted) 1 2 3 (Wall- /Pipe-mounted Model) 4680/500 IP66 C – Within Environmental Limits 55°C Max. –20°C Min. B – Within Temperature Limits 1000m (3281 ft) max. A – Maximum Distance Between Instrument and Interface Unit 2 PREPARATION 3 MECHANICAL INSTALLATION 2.1 Checking the Instrument Type 2.1.1 Wall-mounted Instruments – Fig. 2.1 2.1.2 Panel-mount

Mark fixing centres

(see Fig. 3.2) Drill suitable holes Secure instrument to wall using suitable fixings 1 2 3 Position ‘U’ bolts on pipe Position plates over ‘U’ bolts Secure transmitter to mounting plate Secure plates 1 2 3 4 A – Wall-mounting B – Pipe-mounting 68 (2.68) 214 (8.43) 232 (9.13) Fixing Centres 160 (6.3) 250 (9.84) 69 (2.72) Fixing Centres Allowance for Cable Bends 200 (7.9) 42 (1.65) 61 (23/8) O.D. Vertical or Horizontal Post

ABB Transmitter Owners Instructions: