Norac UC4.5 Installation Manual
Read Online
Read the Norac UC4.5 Installation Manual online using the built-in PDF viewer.
Text of the manual
Printed in Canada
Copyright 2014 by NORAC Systems International Inc.
Reorder P/N: UC4.5-BC-SS1-INST Rev B (Sprayer Specialties 60’, 80’, 90’ Contour Boom)
NOTICE: NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and
without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information
contained in this manual. The technical information in this manual was reviewed at the time of approval for publication.
Introduction ................................................................................................................ 1
2
General UC4.5 System Layout ................................................................................. 2
3
Kit Parts ...................................................................................................................... 3
4
Pre-Install Checklist ................................................................................................... 7
5
Ultrasonic Sensor Installation .................................................................................. 8
6
Roll Sensor Installation ............................................................................................ 12
7
Electrical Installation ............................................................................................... 15
8
Hydraulic Installation .............................................................................................. 18
9
Software Setup ......................................................................................................... 22
10 Cable Drawings ........................................................................................................ 23
11 Appendix A – Optional Main Lift Sensor Installation .......................................... 31
Congratulations on your purchase of the NORAC UC4.5 Spray Height Control System. This
system is manufactured with top quality components and is engineered using the latest
technology to provide operating reliability unmatched for years to come.
When properly used the system can provide protection from sprayer boom damage, improve
sprayer efficiency, and ensure chemicals are applied correctly.
Please take the time to read this manual completely before attempting to install the system. A
thorough understanding of this manual will ensure that you receive the maximum benefit from
the system.
Your input can help make us better! If you find issues or have suggestions regarding the parts
list or the installation procedure, please don’t hesitate to contact us.
Every effort has been made to ensure the accuracy of the information contained in
this manual. All parts supplied are selected to specially fit the sprayer to facilitate
a complete installation. However, NORAC cannot guarantee all parts fit as
intended due to the variations of the sprayer by the manufacturer.
Please read this manual in its entirety before attempting installation.
General UC4.5 System Layout
Figure 1 illustrates the general layout of the UC4.5 system components:
Figure 1: General UC4.5 System Layout
Do not use high speed power tools/drills when installing hardware.
The use of dielectric grease is not recommended on any NORAC electrical
connections.
To ensure all stainless steel hardware does not gall or seize apply a light coating of
the supplied Permatex Anti-seize grease to all threaded parts upon installation.
Permatex Anti-seize lubricant is preferred, but other similar anti-seize products
may be used.
List of Parts
Item
Part Number
Name
Quantity
B01
44971-05
U-BOLTS WITH HARDWARE FOR LP BRACKET MOUNTING
2
B05
44706-01
KIT CABLE TIE BLACK 10 PCS 21 IN 150 PCS 7.5 IN
1
B17
44972
SENSOR MOUNTING BRACKET LOW PROFILE RAINFLAP 16GA
2
B20
44971
SENSOR MOUNTING BRACKET LOW PROFILE 16GA
2
C03
44656D
CABLE VALVE VARIABLE RATE DT
1
C05
43210-15
CABLE UC5 NETWORK 18 AWG 15M
2
C07
43220-01
CABLE UC5 NETWORK 14 AWG 1M
1
C10
44650-50
CABLE UC4.5 POWER SELF-PROPELLED TYPE
1
C11
44651-50
CABLE UC4.5 EXTENSION VALVE GENERIC
1
C12
44658-18
CABLE VALVE UC4 AP2 MAIN
1
C13
44658-34
CABLE UC4 INTERFACE BYPASS GP2
1
C16
44658-111
CABLE INTERFACE UC4 ROLL SENSE GP
1
C30
43250-06
43250-06 CABLE UC5 BATTERY PIGTAIL FUSED - 5A
1
E01
45100
UC4.5 BOOM CONTROL PANEL
1
E03
43742
UC5 ROLL SENSOR W TEMPERATURE PROBE
1
E04
43741
UC5 ROLL SENSOR VER. 2
1
E05
43750
UC5 ULTRASONIC SENSOR
2
E11
43765
UC5 NETWORK COUPLER 8-WAY
1
E12
43764
UC5 NETWORK COUPLER 2-WAY
2
E20
43764T
UC5 NETWORK COUPLER 2-WAY WITH TERMINATOR
2
H01
44863-06
HOSE ASSEMBLY 122R2-06 40 IN L 6FJX 6FJX90
2
H02
44863-29
HOSE ASSEMBLY 122R2-06 36 IN L 8FJX90 6FJX
2
H10
44865-74
HYDRAULICS FITTING KIT - SS
1
M01
UC4.5-BC-MANUAL-
OPERATOR
OPERATOR MANUAL UC4.5 SPRAY HEIGHT CONTROL
1
M02
UC4.5-BC-SS1-INST
MANUAL INSTALLATION UC4.5 SPRAYER SPECIALTIES
1
P03
105882
UC5 NETWORK 6 PIN PLUG
3
V01
44963D
VALVE BLOCK ASSEMBLY 2 STATION CC/LS PROP DT 4 BOLT
1
3.4
Optional Main Lift Kit
An optional main lift sensor kit is available for purchase from NORAC.
Part Number
Name
4571BC
UC4.5 MAIN LIFT OPTION - 44973
Hydraulic Fitting Kit Details (P/N: 44865-74)
Item
Part Number
Name
Quantity Picture
F01
44928
ORIFICE INSERT .047 IN ONE WAY
2
F02
104369
PLUG - 6MBP
2
F03
103312
MALE ADAPTER - 6MB 6MJ
4
F04
103839
TEE ADAPTER - 6FJXR 6MJT
2
F05
42997-01
MALE ADAPTER - 8MB 8MJ - 1/32 ORIFICE
2
F06
104632
TEE ADAPTER 8FJXR 8MJT
4
6 M B - 6 M OR X 90
SIZE IN
1/16TH'S
GENDER: MALE
OR FEMALE
90° ANGLE
SWIVEL
TYPE
GENDER
SIZE
TYPE:
B - ORB
J - JIC
OR - FLAT
FACE
P - PIPE
Fitting Name
Example:
The pre-install checklist is necessary to check the existing sprayer functionality before the
installation.
1. Unfold the sprayer over a flat, unobstructed area (i.e. no power lines…etc.).
2. Ensure all boom-fold operations are functional (place a check mark in boxes below).
3. Bring engine to field-operational RPM and record below.
4. Record the time (seconds) it takes for a full stroke for all boom functions. To ensure
repeatable measurements, take the average of 3 trials.
5. Not all sprayers will have the functions listed below in Figure 4.
Ensure the boom has sufficient travel so it does not contact the ground during
these tests.
Figure 4: Pre-Install Boom Speeds
Ultrasonic Sensor Installation
5.1
Ultrasonic Sensor Serial Number Arrangement
When installing the sensors, start with the smallest serial number on the left-hand side, and
proceed to the largest serial number on the right hand side. Each sensor has a serial number
stamped on the sensor housing.
Apply a light coating of the supplied Permatex Anti-seize grease to all threaded parts upon
installation.
Figure 5: Sensor Serial Number Arrangement
Low Profile Bracket Mounting Guidelines
1. Minimize the distance between the bolts to prevent bending the bracket and prevent the
bracket from loosening over time.
2. Ensure the bracket is mounted tight against the bottom of the boom, minimizing the
distance between the boom structure and the angled flange.
Figure 6: Bracket Mounting Guidelines
A problem can arise if a sensor is not mounted correctly. It is possible for the
sensor to read off of the boom instead of the ground. This may only become
apparent once the control system is switched from soil to crop mode.
Also be careful that the sensor bracket does not collide with any other part of the
boom when the boom is folded to transport position. If possible, mount the sensor
brackets while the booms are folded to ensure they will not cause interference.
Wing Sensor Installation
1. The sensor bracket should be oriented forward (ahead of the boom).
2. Typically the best mounting location for the wing sensor brackets will be near the end of
the boom tips, approximately two feet (60cm) from the end.
3. Depending on the boom design, some breakaway sections will lift upwards as they break
back. If the sensor is mounted to this portion of the boom, the system will force the boom
downwards towards the ground as the boom folds backwards.
4. Mount the sensor bracket onto the boom using the U-bolts provided (B01).
5. Mount the NORAC ultrasonic sensor into the sensor bracket and run the sensor cable
either through hole in the back or through the side cut-out and behind the bracket. Ensure
the cable is clear of moving parts and will not be damaged during folding.
Figure 7: Bracket Mounting Example
Rainflaps are only installed in the wing sensor brackets and are not installed for
120’ booms.
1. Insert one side of the rainflap rod into the pre-bent hinge tab on the sensor bracket.
(Figure 8)
Figure 8: Rainflap Rod in Pre-Bent Hinge Tab
2. Align the other side of the rainflap rod with the unbent hinge tab. (Figure 9)
Figure 9: Align Rainflap Rod
3. Bend the hinge tab inward over the rainflap rod until the hinge tab fits securely in the detent
groove on the backside of the sensor bracket. (Figure 10)
Figure 10: Bend Rainflap Hinge Tab
4. Ensure the rainflap actuates smoothly when the bracket is turned upside down and returns
to the open position when the sensor bracket is returned to its operating position (sensor
pointing downwards toward the ground).
Roll Sensor Installation
6.1
Bracket Assembly
1. Securely mount the roll sensors to the included roll sensor brackets using the #6 machine
screws. Tighten screws to 10 in-lbs (1.1 Nm).
2. The orientation of the mounted roll sensor to the roll sensor bracket will depend on the
bracket mounting. The roll sensor CANbus connector must be pointing towards the right
side of the sprayer (when looking from the rear of the sprayer).
Figure 11: Mounting Roll Sensor to Bracket
Figure 12: Roll Sensor Orientation - Connector Facing Right Wing
Roll Sensor Mounting Guidelines
1. When mounting the roll sensors, mount the roll sensor without the temperature probe on
the boom frame and the roll sensor with the temperature probe on the chassis.
Figure 13: Roll Sensor and 8-Way Coupler Mounting
2. Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.
3. Both roll sensor cables should be pointing towards the right hand wing of the sprayer.
4. Ensure both roll sensors are mounted adequately and that the cables provide enough slack
to allow sufficient boom roll.
Chassis Roll Sensor
With Temperature Probe
Boom Frame Roll Sensor
8-Way Coupler
Once the block is mounted, fasten the temperature probe from E03 to the NORAC valve
block using the included 3/8x1/2” bolt as illustrated in Figure 14.
Figure 14: NORAC Valve Block with Temperature Probe Installed
1. Install the UC4.5 Control Panel (E01) in the cab of the sprayer. Mount the panel where it
will be clearly visible and within easy reach of the operator.
A good spot to mount the UC4.5 control panel is on the right hand side of the cab to the
Roll Over Protection Bar. Four pilot holes for the screws provided need to be drilled to
facilitate the control panel mounting.
Another option is to purchase an adapter for the flexible panel mount that has a 3/8" NC
threaded stud on the end to bolt through an existing mount. These are available at your
local outdoor store as a RAM mount part number RAM-B-236. (See http://www.ram-
mount.com/)
Figure 15: Cable Configurations: C10, C11 and C30
2. Connect the UC4.5 power cable (C10) to the UC4.5 Control Panel in the cab. Ensure that
both plugs (P16 and P4) are connected to the panel. Cable tie C10 to the RAM mount to
help provide strain relief.
3. Connect cable C30 to P6A of C10 using a 2-way coupler (E12). Connect C30 to an
appropriate power supply.
Ensure the UC4.5 Control Panel’s power is OFF for the remaining installation.
(Bottom of switch pressed IN).
4. Route the P12/P6 of C10 out of the cab.
5. Connect P12/P6 to R12/R6 of the extension cable (C11) outside of the cab.
6. Run cable C11 to the rear of the sprayer, in the vicinity of the valve block.
Figure 16: Cable Configurations: C03, C11, C12, C13 and C16
7. Connect the 3-pin tower (T3) on cable C16 to S3 on C11.
8. Insert the 2-pin tees (S2A-T2A - S2D-T2D) of C16 between the matching valve connections
(Left Up, Left Down, Right Up, Right Down) on the sprayer valve block.
9. Connect the 6-pin shroud on cable C12 to T6 on C11.
10. Insert the 2-pin tees (S2A-T2A and S2B-T2B) of C12 between the matching valve
connections (Main Up, Main Down) on the sprayer valve block.
11. Connect the 3-pin shroud (S3) on cable C13 to T3 on C11.
12. Insert the 2-pin tee of C13 between the bypass valve connection on the sprayer valve block.
Figure 17: Interface Wiring Depiction
Bypass
Left Up
Main Up
Right Up
Left Down
Main Down
Right Down
13. Connect the valve interface cable (C03) to connector S6 on the valve extension cable
(C11).
14. Connect the 2-pin connectors on the valve interface cable to the NORAC valve block, as
shown in Figure 18.
15. The connectors on the valve cable (C03) are marked RIGHT UP, LEFT UP, RIGHT
DOWN and LEFT DOWN. Cables labeled with UP go on the same side as the
hydraulic hoses.
Figure 18: Valve Cable Connections
16. Fasten the 8-way coupler to the boom with cable ties as shown in Figure 13. Connect P6
on C11 to the 8-way coupler.
17. Connect the boom frame roll sensor to the 8-way coupler.
18. Connect the chassis roll sensor (temp. probe) to the 8-way coupler using cable C01 and a
2-way coupler (E12).
19. Connect two cables (C05) to the 8-way coupler and route along the booms to the wing
sensors. Follow existing cables and hoses to be sure the cable will not be pinched or
stretched.
20. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.
The 2-way coupler with terminator is the white 2-way coupler. Plug the sensor and the
CANbus cable into the 2-way coupler.
21. Insert the 6-pin plugs (P03) into the remaining connections on the 8-way coupler.
IMPORTANT:
Provide enough slack in all cables to account for the movement of the main
section, parallel lift, and FOLDING boom movement.
Ensure all pressure has been bled from the system before disconnecting any lines
or fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings
are being supported by other means. The hydraulic installation may be performed
with the wings in transport position, resting on the ground or with the tilt cylinders
fully extended.
Component failure due to oil contamination is not covered under the NORAC
UC4.5 system warranty. It is recommended that a qualified technician perform the
hydraulic installation.
8.1
Valve Assembly
1. On a clean surface remove the plastic plugs from the block.
2. Install two 6MB 6MJ fittings (F03) into the “P” and “T” ports on the NORAC block.
Tighten to 18 ft-lbs (24 Nm).
3. Insert the orifices (F01) into the “B” ports with the notch facing out.
4. Install the other two 6MB 6MJ fittings (F03) into the “B” ports on the NORAC block.
Tighten to 18 ft-lbs (24 Nm).
5. Install the 6MBP plugs (F02) into the “A” ports on the NORAC block and tighten to 18 ft-
lbs (24 Nm).
Figure 19: NORAC Valve Block Details
Valve Block Mounting
Ensure that no hydraulic components will interfere with any sprayer parts or be
pulled tight at any time.
The recommended mounting location is on the cross beam between the
parallel lift arms on the main section.
1. A suitable mounting location for the valve block is illustrated in Figure 20.
2. Insert the threaded rod into the block and use a hex nut to hold the rod. The block holes
are 3/8” NC-1” deep. If bolts are used instead of the threaded rod, ensure the bolts thread
in at least 3/8”.
3. Use the remaining hardware to secure the block to the sprayer.
4. Cut off excess threaded rod, if necessary.
Figure 20: Valve Block Mounting
From this point on in the installation the booms will be inoperative until the hydraulics are fully
installed.
1. After the NORAC valves are mounted, the hydraulic hoses and fittings can be plumbed
following the schematic in Figure 3.
2. Attach the 90° end of hose H01 to the NORAC valve block pressure port.
3. Route hose H01 to the sprayer valve block. Tee the hose into the sprayer pressure port
using a 6FJXR 6MJT fitting (F04). (Figure 21)
4. Attach the 90° end of hose H01 to the NORAC valve block tank port.
5. Route hose H01 to the sprayer valve block. Tee the hose into the sprayer tank port using a
6FJXR 6MJT fitting (F04). (Figure 21)
Figure 21: Pressure and Tank Tee Location
6. Remove the existing tees from the accumulators used for the wing tilt functions shown in
Figure 22.
Pressure Tee
Tank Tee
Figure 22: Tilt Accumulator Locations
7. Insert the 8MB 8MJ – 1/32 orifice fittings (F05) into each accumulator. Attach two of the
8FJXR 8MJT fittings (F06) in line on each accumulator as shown in Figure 23.
Figure 23: Accumulator Hydraulic Fittings
8. Attach the 90° ends of hoses H02 to the tees installed on the accumulators. Route hoses
H02 to the NORAC valve block.
9. Connect hoses H02 to the “B” ports on the NORAC valve block.
10. Connect the original hoses from the sprayer valve block and the wing cylinders to the tees
installed on the accumulators.
11. Tighten all fittings before restarting the machine and attempting to run hydraulic functions.
Right Tilt
Accumulator
Left Tilt Accumulator
1. Test the functionality of the original manufacturer’s boom controls. The NORAC Control
Panel (E01) does not need to be powered up for the original switches to function. Unfold
the booms and raise/lower each boom and main section.
Confirm that the cabling and hoses are agreeable to the entire range of motion.
2. If any functions do not work, review the hydraulic and electrical portions of this manual to
check for proper installation.
3. Turn on the power for the UC4.5 Control Panel using the switch on the side of its chassis.
4. The procedure for the installation of the UC4.5 Spray Height Control system is now
complete. Begin the AUTOMATIC SYSTEM SETUP procedure as described in the UC4.5
Spray Height Control Operator’s Manual (M01).
10.2 ITEM C05: 43210-15 - CABLE UC5 NETWORK 18 AWG - 15M
10.3 ITEM C07: 43220-01 - CABLE UC5 NETWORK 14 AWG - 1M
11 Appendix A – Optional Main Lift Sensor Installation
For complete instructions for installing the main lift sensor, please refer to the manual included
with the main lift kit.
When installing the main lift option, the sensor bracket should be mounted as shown in Figure
24.
Always follow the sensor mounting guidelines to ensure optimal sensor performance and
prevent sensor measurement error.
Figure 24: Main Lift Bracket Mounting Location
Figure 25: Sensor Serial Number Arrangement with Main Lift Sensor
NORAC Systems International Inc.
Phone: (+1) 306 664 6711
Toll Free: 1 800 667 3921
Shipping Address:
3702 Kinnear Place
Saskatoon, SK
S7P 0A6
United States
NORAC, Inc.
Phone: (+1) 952 224 4142
Toll Free: 1 866 306 6722
Shipping Address:
6667 West Old Shakopee Road, Suite 111
Bloomington, MN
55438
Europe
NORAC Europe
Phone: (+33) (0)4 26 47 04 42
Shipping Address:
Rue de l’hermitage
01090 GUEREINS
France
www.norac.ca