NEC SV-8100 System Hardware Manual
Text of the manual
System Hardware Manual
i
___________________________________________________________________________________
___________________________________________________________________________________
TABLE OF CONTENTS
Regulatory
Chapter 1 Introduction to SV8100
Section 1
General Information ....................................................................1-1
Section 2
Equipment List ............................................................................1-4
Chapter 2 SV8100 System Specifications
Section 1
General Information .....................................................................2-1
Section 2
System Block Diagram ................................................................2-1
Section 3
Maximum System Capacities ....................................................2-5
3.1
System Configuration – SV8100 ................................................. 2-6
Section 4
Power-Based Calculator Chart .................................................2-13
Section 5
System Requirements and Specifications ..............................2-16
5.1
Cabling ...................................................................................... 2-16
5.2
Power Requirements ................................................................. 2-19
5.2.1
Power Supply Specifications ....................................................2-19
5.2.2
Power Supply Consumption .....................................................2-20
5.3
Environmental Conditions .......................................................... 2-20
5.3.1
Temperature and Humidity ......................................................2-20
5.4
Outside Line Types .................................................................... 2-21
5.5
Transmission, Network, and Control Specifications .................. 2-21
Table of Contents
___________________________________________________________________________________
5.5.1
Transmission ............................................................................2-21
5.5.2
Network ....................................................................................2-22
5.5.3
Control ......................................................................................2-22
5.5.4
Electra Elite IPK Terminals and Equipment .............................2-23
5.5.5
Series i Terminals ....................................................................2-24
5.6
Dialing Specifications .................................................................2-24
5.6.1
Dial Pulse Address Signaling ...................................................2-24
5.6.2
Dual-Tone Multifrequency (DTMF) Address Signaling .............2-24
5.6.3
External Equipment Connection ...............................................2-25
5.6.4
Music Source for Music on Hold via Chassis ...........................2-25
5.6.5
Music Source for Station Background Music via ACI ...............2-25
5.6.6
External Paging (Audio) ...........................................................2-25
5.6.7
External Tone Ringer/Night Chime Output ...............................2-26
5.6.8
SMDR Output ...........................................................................2-26
5.6.9
PC Connection .........................................................................2-26
5.6.10 Relay Contact ...........................................................................2-26
5.7
Battery Backup ..........................................................................2-26
5.7.1
System Backup (Optional) .......................................................2-26
5.7.2
Memory Backup .......................................................................2-26
5.8
Weights and Dimensions ...........................................................2-27
Chapter 3 Installing the SV8100 Chassis
Section 1
General Information .................................................................... 3-1
Section 2
Installing the Chassis ................................................................. 3-1
2.1
Wall Mounting the 19” Chassis ....................................................3-2
2.1.1
CHS2U Chassis Wall Mount Installation ....................................3-3
2.2
Floor Mounting the 19” Chassis .................................................3-10
System Hardware Manual
- iii
___________________________________________________________________________________
___________________________________________________________________________________
System Hardware Manual
iii
___________________________________________________________________________________
2.2.1
CHS2U Chassis Installation .....................................................3-10
2.2.2
Multiple CHS2U Chassis Installation .......................................3-12
2.3
Stand Mounting the 19” Chassis ............................................... 3-14
2.3.1
CHS2U Chassis Installation .....................................................3-14
2.3.2
Multiple CHS2U Chassis Installation .......................................3-17
2.4
Rack Mounting the 19” Chassis ................................................. 3-20
2.5
Installing the 19” Chassis .......................................................... 3-22
2.5.1
Unpacking the Equipment ........................................................3-22
2.5.2
Before Installation ....................................................................3-22
2.5.3
Installing the 19” Controlling Chassis .......................................3-23
2.5.4
Installing Expansion Blades in the 19” Chassis (Optional) ......3-24
2.5.4.1
Connector Pin-Out on the PZ-BS10/PZ-BS11 ....................3-25
2.5.4.2
Install the PZ-BS10 Expansion Base Blade in the CHS2U Con-
trolling Chassis 3-25
2.5.4.3
Install the PZ-BS11 Expansion Blade in the CHS2U Expansion
Chassis 3-28
2.5.4.4
Connect the Controlling and Expansion Chassis ...............3-32
2.5.5
Install 19” Chassis Grounding ..................................................3-34
2.5.6
Install 19” Grounding on Multiple Chassis (Optional) ...............3-34
2.5.7
Install AC Power Cords ............................................................3-35
2.5.8
Install AC Power Cords on Multiple-Chassis (Optional) ...........3-36
2.5.9
Install Additional Blades ...........................................................3-36
2.5.10 Apply Power to the 19” Chassis ...............................................3-36
Section 3
Battery Connection ...................................................................3-37
3.1
Installing the Internal Batteries ..................................................3-37
3.2
Installing the External Batteries ................................................. 3-43
3.2.1
Floor Mounting the CHS LARGE BATT BOX ..........................3-43
3.2.2
Battery Installation ...................................................................3-45
3.2.3
CHS LARGE BATT BOX to CHS2U Connection .....................3-49
Table of Contents
___________________________________________________________________________________
Section 4
Remove and Install Cooling Fan .............................................. 3-53
4.1
CHS2U Chassis .........................................................................3-53
4.1.1
Remove Cooling Fan ............................................................3-53
4.1.2
Install Cooling Fan ...................................................................3-55
Chapter 4 Installing the SV8100 Blades
Section 1
General Information .................................................................... 4-1
1.1
Slot Locations ..............................................................................4-1
Section 2
Installation .................................................................................. 4-3
2.1
Installation and Safety Precautions .............................................4-3
2.2
Installing an Extension or Trunk Blade ........................................4-4
2.2.1
Installing the Blades ...................................................................4-4
2.2.2
Order of Installing Extension Blades ..........................................4-4
2.2.3
Order of Installing Trunk Blades .................................................4-6
2.2.3.1
Installing CD-4COTA, CD-4DIOPB, CD-4ODTA or CD-2BRIA
blades 4-6
2.2.3.2
Installing CD-PRTA (T1/PRI) Blades ................................... 4-7
2.3
Remove an Extension or Trunk Blade .........................................4-7
2.4
Uninstalling a Blade Slot Through Software ................................4-7
2.5
Blade Capacities ..........................................................................4-8
2.6
Powering Up the SV8100 ............................................................4-8
2.6.1
Performing a Cold Start ..............................................................4-8
2.6.2
Performing a Hot Start ...............................................................4-9
2.6.3
Resetting the System .................................................................4-9
2.6.3.1
Initial Programming .............................................................. 4-9
2.6.3.2
Port Defaults ...................................................................... 4-10
2.6.3.3
Setting Up Extension Circuit Types ................................... 4-10
2.6.3.4
Saving Your Configuration ................................................. 4-11
System Hardware Manual
- v
___________________________________________________________________________________
___________________________________________________________________________________
System Hardware Manual
v
___________________________________________________________________________________
2.6.3.5
Backing Up/Restoring a Database .....................................4-11
2.6.4
Performing a Software Upgrade ..............................................4-12
Section 3
Common Control Blades ..........................................................4-14
3.1
CD-CP00 (SV8100 Central Processing Unit) ............................ 4-14
3.1.1
Description ...............................................................................4-15
3.1.2
Installation ................................................................................4-18
3.1.3
Switch Settings ........................................................................4-20
3.1.4
LED Indications ........................................................................4-20
3.1.5
Connectors ...............................................................................4-22
3.2
PZ-ME50 (Memory Expansion Daughter Board) ....................... 4-25
3.2.1
Description ...............................................................................4-25
3.2.2
Installation ................................................................................4-27
3.3
PZ-VM21 (Voice Mail Daughter Board) .................................... 4-28
3.3.1
Description ...............................................................................4-28
3.3.2
Installation ................................................................................4-29
3.3.3
Switch Settings ........................................................................4-31
3.4
PZ-32IPLA/PZ-64IPLA/PZ-128IPLA (Voice over IP Daughter
Boards) 4-31
3.4.1
Description ...............................................................................4-32
3.4.2
Installation ................................................................................4-33
3.4.3
Switch Settings ........................................................................4-33
3.4.4
LED Indications ........................................................................4-34
3.4.5
Connectors ...............................................................................4-35
Section 4
Station Blades ............................................................................4-37
4.1
CD-8DLCA/CD-16DLCA (Digital Station Interface) .................. 4-37
4.1.1
Description ...............................................................................4-38
4.1.2
Installation ................................................................................4-39
Table of Contents
___________________________________________________________________________________
4.1.3
LED Indications ........................................................................4-39
4.1.4
Connectors ...............................................................................4-40
4.2
PZ-8DLCB (Digital Station Daughter Board) .............................4-42
4.2.1
Description ...............................................................................4-42
4.2.2
Installation ................................................................................4-43
4.2.3
PZ-8DLCB Daughter Board Cable Connection ........................4-43
4.3
CD-4LCA/ CD-8LCA (4-Port/8-Port Single Line Interface) ........4-45
4.3.1
Description ...............................................................................4-46
4.3.2
Installation ................................................................................4-47
4.3.3
LED Indications ........................................................................4-48
4.3.4
Connectors ...............................................................................4-49
4.4
PZ-4LCA/PZ-8LCE (4-Port/8-Port SLI Daughter Boards) ..........4-50
4.4.1
Description ...............................................................................4-52
4.4.2
Installation ................................................................................4-53
4.4.3
Connectors ...............................................................................4-54
4.5
CD-LTA (Dterm/SLT Combination) .............................................4-55
4.5.1
Description ...............................................................................4-55
4.5.2
Installation ................................................................................4-56
4.5.3
LED Indications ........................................................................4-57
4.5.4
Connectors ...............................................................................4-58
Section 5
Trunk Blades ............................................................................. 4-59
5.1
CD-4COTA (4 Loop Start Interface) ..........................................4-59
5.1.1
Description ...............................................................................4-59
5.1.2
Installation ................................................................................4-61
5.1.3
LED Indications ........................................................................4-61
5.1.4
Connectors ...............................................................................4-62
5.2
PZ-4COTE (4 Loop Start Interface Daughter Board) .................4-63
System Hardware Manual
- vii
___________________________________________________________________________________
___________________________________________________________________________________
System Hardware Manual
vii
___________________________________________________________________________________
5.2.1
Description ...............................................................................4-63
5.2.2
Installation ................................................................................4-65
5.2.3
Connectors ...............................................................................4-65
5.3
CD-2BRIA (2 Basic Rate Interface) ...........................................4-67
5.3.1
Description ...............................................................................4-67
5.3.2
Installation ................................................................................4-68
5.3.3
LED Indications ........................................................................4-69
5.3.4
Connectors ...............................................................................4-70
5.3.5
Termination Switch Settings ....................................................4-70
5.4
PZ-2BRIA (2 Basic Rate Interface Daughter Board) ................. 4-72
5.4.1
Description ...............................................................................4-73
5.4.2
Installation ................................................................................4-73
5.4.3
Connectors ...............................................................................4-74
5.4.4
Termination Switch Settings ....................................................4-75
5.5
CD-4DIOPB (DID/OPX Interface) .............................................. 4-76
5.5.1
Description ...............................................................................4-76
5.5.2
Installation ................................................................................4-77
5.5.3
LED Indications ........................................................................4-77
5.5.4
Connectors ...............................................................................4-78
5.6
CD-PRTA (PRI Interface) .........................................................4-79
5.6.1
Description ...............................................................................4-79
5.6.2
Installation ................................................................................4-80
5.6.3
LED Indications ........................................................................4-82
5.6.4
Connectors ...............................................................................4-84
5.7
CD-4ODTA (4-Port Tie Line Interface Blade) ............................ 4-86
5.7.1
Description ...............................................................................4-86
5.7.2
Installation ................................................................................4-87
Table of Contents
___________________________________________________________________________________
5.7.3
LED Indications ........................................................................4-88
5.7.4
Connectors ...............................................................................4-88
5.7.5
Connections .............................................................................4-90
Section 6
Optional Blades ......................................................................... 4-92
6.1
CD-PVAA (Conference Bridge) (Future Enhancement) ............4-92
6.1.1
Description ...............................................................................4-92
6.1.2
Installation ................................................................................4-93
6.1.3
Switch Settings .........................................................................4-93
6.1.4
LED Indications ........................................................................4-93
6.1.5
Connectors ...............................................................................4-94
6.2
CD-RTB (4-Port ) (Future Enhancement) ..................................4-95
6.2.1
Description ...............................................................................4-95
6.2.2
Installation ................................................................................4-97
6.2.3
LED Indications ........................................................................4-97
6.3
CD-ETIA (Gigabit PoE Switch) ..................................................4-98
6.3.1
Description ...............................................................................4-98
6.3.2
Installation ................................................................................4-99
6.3.2.1
Stacking Architecture ......................................................... 4-99
6.3.2.2
CD-CP00IP Address Assignment .................................... 4-100
6.3.2.3
Group Formation .............................................................. 4-100
6.3.2.4
Port Number Determination ............................................. 4-100
6.3.2.5
Unmanaged Switch Functions ......................................... 4-101
6.3.3
LED Indications ......................................................................4-101
6.3.4
Connectors .............................................................................4-101
Chapter 5 Installing DT300/DT700 Series (DTL/ITL) Digital and IP
Multiline Terminals
Section 1
General Description .................................................................... 5-1
System Hardware Manual
- ix
___________________________________________________________________________________
___________________________________________________________________________________
System Hardware Manual
ix
___________________________________________________________________________________
Section 2
DT300 Series Digital Multiline Terminals ..................................5-6
2.1
Digital MultilineTerminals ............................................................. 5-6
2.1.1
DTL-2E-1 (BK) TEL ....................................................................5-6
2.1.2
DTL-6DE-1 (BK) TEL .................................................................5-7
2.1.3
DTL-8LD-1 (BK) TEL/DTL-8LD-1 (WH) TEL ..............................5-7
2.1.4
DTL-12BT-1 (BK) TEL ...............................................................5-8
2.1.5
DTL-12D-1 (BK) TEL/DTL-12D-1 (WH) TEL ..............................5-9
2.1.6
DTL-12PA-1 (BK) TEL .............................................................5-10
2.1.7
DTL-24D-1 (BK) TEL/DTL-24D-1 (WH) TEL ............................5-11
2.1.8
DTL-32D-1 (BK) TEL/DTL-32D-1 (WH) TEL ............................5-12
Section 3
DT700 Series IP Multiline Terminals ........................................5-14
3.1
IP MultilineTerminals ................................................................. 5-14
3.1.1
ITL-2E-1 (BK) TEL ...................................................................5-14
3.1.2
ITL-6DE-1 (BK) TEL .................................................................5-15
3.1.3
ITL-8LD-1 (BK) TEL/ITL-8LD-1 (WH) TEL ...............................5-15
3.1.4
ITL-12D-1 (BK) TEL/ITL-12D-1 (WH) TEL ...............................5-16
3.1.5
ITL-12PA-1 (BK) TEL ...............................................................5-17
3.1.6
ITL-24D-1 (BK) TEL/ITL-24D-1 (WH) TEL ...............................5-18
3.1.7
ITL-32D-1 (BK) TEL/ITL-32D-1 (WH) TEL ...............................5-19
3.1.8
ITL-320C-1 (BK) TEL ...............................................................5-20
Section 4
Install Multiline Terminals .........................................................5-22
4.1
Connecting the DT300 Series Multiline Terminal to the System 5-22
4.2
Applying Power to the DT700 Multiline Terminals ..................... 5-23
4.3
Connecting the IP Multiline Terminal to the Network and PC .... 5-24
4.4
Adjusting the LCD on the Multiline Terminal ............................. 5-25
4.5
Installing Line Key Kit (12LK-L KIT) ...........................................5-26
Table of Contents
___________________________________________________________________________________
4.5.1
Installing the 12LK-L KIT ..........................................................5-26
4.5.2
Configuring the Digital Telephone for the Correct Number of Line
Keys 5-30
4.5.3
Configuring the IP Telephone for the Correct Number of Line Keys
5-30
4.6
Installing the Directory Card on the Multiline Terminal ..............5-32
4.7
Installing a Numbered Keypad on the Multiline Terminal ..........5-33
4.7.1
Installing the Numbered Keypad on a Multiline Terminal ........5-35
4.7.2
Configuring the Digital Telephone for the Numbered Keypad ..5-37
4.7.3
Configuring the IP Telephone for the Numbered Keypad ........5-37
4.8
Adjusting the Height on the Multiline Terminal ..........................5-39
4.9
Removing or Installing the Tilt Legs on the Multiline Terminal ..5-40
4.9.1
Remove Tilt Legs .....................................................................5-40
4.9.2
Install Tilt Legs .........................................................................5-41
4.10
Wall Mounting the Multiline Terminal .........................................5-43
4.10.1 Wall Mounting a Multiline Terminal using the Base Plate ........5-43
4.10.1.1
Adjusting the Hanger Hook ................................................ 5-43
4.10.1.2
Wall Mounting the Multiline Terminal ................................. 5-44
4.10.1.3
Removing the Multiline Terminal from the Wall Mounted Base
Plate. 5-45
4.10.1.4
Wall Mounting the Base on a Switch Box .......................... 5-46
Section 5
Multiline Terminals Optional Equipment ................................ 5-47
5.1
DT300/DT700 Series Terminal Options .....................................5-47
5.2
DT300/DT700 Series Optional Terminal Equipment .................5-48
5.2.1
8LK-L (BK) UNIT/8LK-L (WH) UNIT .........................................5-48
5.2.1.1
Installing the 8LK-L UNIT ................................................... 5-48
5.2.2
8LKD (LD)-L (BK) UNIT/8LKD (LD)-L (WH) UNIT ...................5-50
5.2.2.1
Installing the 8LKD (LD)-L UNIT ........................................ 5-51
5.2.3
8LKI (LD)-L (BK) UNIT/8LKI (LD)-L (WH) UNIT .......................5-54
System Hardware Manual
- xi
___________________________________________________________________________________
___________________________________________________________________________________
System Hardware Manual
xi
___________________________________________________________________________________
5.2.3.1
Installing the 8LKI (LD)-L UNIT ..........................................5-55
5.2.4
DCL-60-1 (BK) CONSOLE/DCL-60-1 (WH) CONSOLE .........5-58
5.2.4.1
Installing the DCL-60-1 CONSOLE ....................................5-59
5.2.5
LCD (BL)-L (BK) UNIT/LCD (BL)-L (WH) UNIT .......................5-63
5.2.6
PANEL( )-L UNIT ....................................................................5-64
5.2.7
WM-L UNIT Attached to Wall ...................................................5-64
5.2.8
Release the WM-L UNIT ..........................................................5-66
5.2.9
WM-L UNIT Attached to Wall Plate ..........................................5-67
5.2.10 Removing the Multiline Terminal from the Wall Mounted Plate. .....
5-69
Section 6
Optional Handsets .....................................................................5-70
6.1
ITL / DTL PTM Handset ............................................................. 5-70
6.2
ITL / DTL PTT Handset ............................................................. 5-70
6.3
UTR-1-1 USB Handset .............................................................. 5-71
6.3.1
Handset Connection ................................................................5-71
6.3.2
USB Connection ......................................................................5-71
6.3.3
Wall Mounting ..........................................................................5-72
Section 7
Bluetooth Cordless Handset ....................................................5-73
7.1
Bluetooth Cordless Handset (BCH) Interface ............................ 5-73
7.2
Selecting a Location .................................................................. 5-74
7.3
Controls and Indicators .............................................................. 5-75
7.4
Installing the Bluetooth Cordless Handset ................................. 5-77
7.4.1
Installing the Bluetooth Handset Cradle ...................................5-77
7.4.2
Wall Mounting the Bluetooth Cradle ........................................5-83
7.4.3
Remove and Replace Handset Battery ....................................5-86
Section 8
Bluetooth Hub Adapter .............................................................5-87
Table of Contents
___________________________________________________________________________________
8.1
Bluetooth Hub Adapter (BHA) Features ....................................5-87
8.1.1
Installing the BHA-L UNIT ........................................................5-87
8.1.2
Pairing a Bluetooth Device and Multiline Terminal (Bluetooth In-
stalled) 5-89
8.1.2.1
Accessing the Bluetooth Device Setup Screen .................. 5-89
8.1.2.2
Entering a PIN Code .......................................................... 5-89
8.1.2.3
Pairing ................................................................................ 5-89
8.1.2.4
Connecting the Paired Device ........................................... 5-90
8.1.2.5
Unpairing ........................................................................... 5-90
8.1.2.6
Visibility Setting .................................................................. 5-90
8.1.2.7
BT Information ................................................................... 5-91
Section 9
Single Line Telephone .............................................................. 5-92
9.1
Installing the SLT Adapter .........................................................5-92
9.2
Wall-Mounting the SLT Adapter .................................................5-93
Chapter 6 Installing SV8100 Optional Equipment
Section 1
General Information .................................................................... 6-1
Section 2
PGD(2)-U10 ADP .......................................................................... 6-1
2.1
Using a PGD(2)-U10 ADP ...........................................................6-1
2.2
LED Indications ............................................................................6-2
2.3
Setting up PGD(2)-U10 ADP Connections ..................................6-2
Section 3
Background Music .................................................................... 6-10
3.1
Installing Background Music ......................................................6-10
Section 4
Door Box .................................................................................... 6-11
4.1
Installing a Door Box ..................................................................6-11
Section 5
External Paging ......................................................................... 6-15
System Hardware Manual
- xiii
___________________________________________________________________________________
___________________________________________________________________________________
System Hardware Manual
xiii
___________________________________________________________________________________
5.1
External Page ............................................................................ 6-15
5.2
Installing an External Page System ...........................................6-15
Section 6
External Paging and Door Box/Page Relays ...........................6-17
6.1
External Page Relays ................................................................6-17
6.2
Door Box /External Page Relay Contacts .................................. 6-18
6.2.1
Connecting a Contact Relay Device to a Door Box/External Page
Relay 6-18
Section 7
External Recording System/External Ringer ..........................6-19
7.1
External Recording System or External Ringer ......................... 6-19
7.2
Installing an External Recording System or External Ringer ..... 6-20
7.3
Programming ............................................................................. 6-21
Section 8
Music Sources ...........................................................................6-24
8.1
Music on Hold ............................................................................ 6-24
8.2
Installing External Music on Hold .............................................. 6-24
Section 9
Night Mode Selection ................................................................6-27
9.1
Night Mode Selector Switch ...................................................... 6-27
9.2
Connecting a Night Mode Selector Switch ................................ 6-27
Section 10 Telephone Labeling ...................................................................6-27
10.1
DESI Printer Sheets .................................................................. 6-27
10.1.1 Removing the Faceplate ..........................................................6-28
10.1.2 Replacing the Faceplate ..........................................................6-28
Section 11 Telephone Adapters ..................................................................6-29
11.1
Using Adapters .......................................................................... 6-29
11.2
In-line Power Adapter (ILPA-R) ................................................. 6-29
Table of Contents
___________________________________________________________________________________
11.2.1 Conditions ................................................................................6-30
11.2.2 Installation ................................................................................6-31
11.3
ADA-L UNIT ...............................................................................6-33
11.3.1 ADA-L UNIT Switch Settings ....................................................6-34
11.3.2 Installing the ADA-L UNIT ........................................................6-35
11.3.3 ADA-L UNIT Connection ..........................................................6-37
11.3.3.1
ADA-L UNIT Connection for Recording Only ..................... 6-37
11.3.3.2
ADA-L UNIT Connection for Sending Recorded Calls to the
Telephone 6-38
11.4
APR-L UNIT ...............................................................................6-38
11.4.1 APR-L UNIT Switch Settings ....................................................6-39
11.4.2 Installing the APR-L UNIT ........................................................6-39
11.5
PSA-L (BK) UNIT / PSA-L (WH) UNIT .......................................6-43
11.5.1 Installing the PSA-L Adapter ....................................................6-44
11.5.2 Using the PSA-L Adapter .........................................................6-50
Section 12 Power Failure Telephones ........................................................ 6-51
12.1
Power Failure .............................................................................6-51
12.2
Connector Pin-Outs on COIU Blade for Power Failure Circuits 6-52
12.3
Installing the Power Failure Telephones ....................................6-52
System Hardware Manual
R-1
BATTERY DISPOSAL
The UNIVERGE SV8100 system includes the batteries listed below. When disposing of these
batteries, Chassis, and/or Blades, you must comply with applicable regulations regarding proper
disposal procedures.
The UNIVERGE SV8100 CD-CP00 provides memory backup for approximately three years. The
Lithium battery should be replaced every two years.
IMPORTANT SAFEGUARDS FOR BATTERY DISPOSAL
DO NOT PLACE USED BATTERIES IN YOUR REGULAR WASTE! THE PRODUCT YOU
PURCHASED CONTAINS LITHIUM, NICKEL-CADMIUM OR SEALED LEAD BATTERIES. LITHIUM,
NICKEL-CADMIUM OR SEALED LEAD BATTERIES MUST BE COLLECTED, RECYCLED, OR
DISPOSED OF IN AN ENVIRONMENTALLY SOUND MANNER.
The incineration, landfilling or mixing of nickel-cadmium or sealed lead batteries with the municipal
solid waste stream is PROHIBITED BY LAW in most areas. Contact your local solid waste
management officials for other information regarding the environmentally sound collection, recycling,
and disposal of the battery.
Table R-1 Battery Types and Quantities for Chassis and Blades
Unit Name
Type of Battery
Quantity
CD-CP00
Lithium
1
CHS LARGE BATT SET
Sealed Lead
6
Internal Batteries
Sealed Lead
2
Bluetooth® Cordless Handset
Lithium-ion
1
Regulatory
Nickel-Cadmium (or sealed lead) batteries must be returned to an approved nickel-cadmium (or sealed
lead) battery recycler. This may be where the batteries were originally sold or a local seller of automotive
batteries. Contact your local waste management officials for other information regarding the
environmentally sound collection, recycling and disposal of the battery contained in this product.
The packaging for the UNIVERGE SV8100 system contains the following labels regarding proper
disposal.
PRODUCT PACKAGE LABELING
CONTAINS NICKEL-CADMIUM BATTERY.
BATTERY MUST BE RECYCLED OR
DISPOSED OF PROPERLY. MUST NOT BE
DISPOSED OF IN MUNICIPAL WASTE.
CONTAINS SEALED LEAD BATTERY.
BATTERY MUST BE RECYCLED. MUST NOT
BE DISPOSED OF IN MUNICIPAL WASTE.
Pb
Ni-Cd
CONTAINS NICKEL-METAL HYDRIDE
BATTERY. BATTERY MUST BE RECYCLED
OR DISPOSED OF PROPERLY. MUST NOT
BE DISPOSED OF IN MUNICIPAL WASTE.
Ni-MH
System Hardware Manual
R-3
EUROPEAN UNION INFORMATION
Notice to the user
The system described in this manual is intended to be connected to analog and digital networks and
supports a wide range of peripheral equipment. The following interfaces are available for connection to
public analog and digital telecommunication networks:
�
TBR3 ISDN basic rate interface
�
TBR4 ISDN primary rate interface
�
ES203-021 Analogue interface
To take advantage of all features of this system and the connected equipment, the country or network
specific features should match the supported features of the system. For an overview of the supported
features, refer to the detailed documentation that comes with this system, contact your local NEC Philips
representative or the support desk of NEC Philips Unified Solutions.
Declaration of conformity
Hereby, “NEC Philips Unified Solutions”, declares that the SV8100 is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC.
http://www.nec-philips.com/doc
Electromagnetic Compatibility
For the SV8100 system the following warning is applicable:
Warning
This is a class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
PRODUCT DISPOSAL INFORMATION
For Countries in the European Union
The symbol depicted here has been affixed to your product in order to inform
you that electrical and electronic products should not be disposed of as
municipal waste.
Electrical and electronic products including the cables, plugs and accessories
should be disposed of separately in order to allow proper treatment, recovery
and recycling. These products should be taken to a designated facility where
the best available treatment, recovery and recycling techniques are available.
Separate disposal has significant advantages: valuable materials can be re-
used and it prevents the dispersion of unwanted substances into the municipal
waste stream. This contributes to the protection of human health and the
environment.
Please be informed that a fine may be imposed for illegal disposal of electrical
and electronic products via the general municipal waste stream.
In order to facilitate separate disposal and environmentally sound recycling arrangements have been
made for local collection and recycling. In case your electrical and electronic products need to be
disposed of please refer to your supplier or the contractual agreements that your company has made
upon acquisition of these products.
At www.nec-philips.com/weee you can find information about separate disposal and environmentally
sound recycling.
Battery information
Defective or exhausted batteries should never be disposed of as municipal waste. Return old batteries to
the battery supplier, a licensed battery dealer or a designated collection facility. Do not incinerate
batteries. This product uses Lithium batteries. Do not use any other type.
For an overview of the location of batteries used in these systems, the battery replacement or removal
instructions, please refer to the UNIVERGE SV8100 System Hardware Manual.
System Hardware Manual
1 - 1
Chapter
1
Introduction to SV8100
SECTION 1
GENERAL INFORMATION
The SV8100 is a full-featured IP based communications system providing
a rich feature set of existing system, with pure Voice over IP (VoIP)
communications, across corporate Local and Wide Area Networks (LAN
and WAN).
The DT700 series telephones provide a converged infrastructure at the
desktop, with a 10Base-T/100Base-TX connection to the LAN and built-in
hub for a PC connection to the telephone itself. The system can provide
peer-to-peer connections between the DT700 series telephones with voice
compression, offering existing IP telephone features with an enhanced
user interface. On the WAN side, the system can provide peer-to-peer
connections over IP networks with the voice compression on CCIS over IP.
The SV8100 can provide legacy line/trunk interfaces to support the
existing Time Division Multiplexing (TDM) based infrastructure, such as
analog telephones, digital telephones (DT300 series), analog networks
and digital networks (T1/E1, ISDN, etc.).
The new compact 19” chassis provides 104 total ports (80 digital
terminals) and can be expanded, using three additional 19” chassis, for a
maximum of 416 ports (320 digital terminals). Through IP connection and
four additional 19” chassis, the system can be expanded to a maximum of
512 ports for SV8100 and a maximum of 1024 for SV8300 (refer to Table
2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels on
page 2-5).
Communications between legacy stations/trunks and DT700 series
telephones/IP networks are made using a VoIP blade, which converts
packet-based voice data to TDM-based voice data, and vice versa. Both
peer-to-peer connections and TDM-based connections are controlled by
the CPU blade. The CPU incorporates a built-in Device Registration
Server (DRS) and a single interface point of IP connection to IP telephone,
PCPro and OAI / ACD servers. Figure 1-1 shows a simplified view of
SV8100 system connectivity.
1 - 2
Introduction to SV8100
Highlights of the UNIVERGE SV8100 are as follows:
�
Pure IP System capable TDM configuration
The SV8100 supports both pure IP switching (peer-to-peer connections) and
Time Division Switching. The pure IP switching is provided for communications
between DT700 series telephones and for CCIS / Remote Unit connections with
other SV8100. On the other hand, the TDM switching is provided for
communications between legacy stations/trunks. Connection between IP
network and legacy network is made via VoIP blade on the CPU blade, which
converts packet-based voice data to TDM-based voice data, and vice versa.
�
Powerful CPU Blade with Built-in Functionalities
The CPU blade of SV8100 is a heart of pure IP connections and TDM-based
connections. The CPU blade employs a 32 bit microprocessor. With this
processing power and DSP technology, it integrates the following functions on
one board. These functions are managed with software licenses.
�
DTMF receivers
�
Caller ID receivers
�
Caller ID senders
Figure 1-1 Simplified SV8100 System Connectivity
System Hardware Manual
1 - 3
�
MF senders / receivers
�
10/100 Ethernet Port
�
2 Control Relays
�
MOH Input Port
�
Paging Output Port
�
In-Mail (VMDB)
�
VoIP.
In addition, by means of advanced LSI technology, size of the CPU blade is
minimized, O&M NIC port (10/100M) is built in and VoIPDB which has VoIP NIC
port (Gigabit Ethernet) is mountable without additional slots in the chassis. The
O&M NIC port is linked with LAN/WAN for inter-work with PCPro, SMDR, OAI
server, and the VoIP NIC port is linked with LAN/WAN for control signaling and
voice signaling (RTP) for DT700 series, etc.
�
High Density Legacy Line/Trunk Blades
Major legacy line/trunk blades used in SV8100 are provided with main blade +
daughter blade architecture. When the main blade is mounted only in an initial
supply, line/trunk interfaces can be easily expanded by adding the daughter
blade. The maximum number of ports for the line/trunk blades is 8/16 ports with
daughter blade, respectively. This allows the physical system size to be
compact.
�
Universal Blade Slot (19” Chassis)
A 19” Chassis is used for legacy line/trunk blades. One 19” Chassis provides six
universal slots and one expansion slot. Also, the universal slots can be used for
special application blades without complicated limitation. This makes easy
quotation and installation.
�
Easy Installation (Front Cabling and Enhanced O&M Tool)
Cable connectors (RJ-45 or RJ-61) are located on the front panel of each
chassis and blade. It increases efficiency of the cabling work. Also, PCPro
provides an enhanced user interface. A Quick Setup tool provides easy setup
(system data programming) for a basic system configuration in shorter time.
1 - 4
Introduction to SV8100
SECTION 2
EQUIPMENT LIST
The following tables list all equipment for the SV8100 systems.
Table 1-1 Chassis Equipment List
Equipment Name
Equipment Description
Product Code
CHS2U
19” Chassis (6-slot)
SV8100
MPS7101
Power Supply Unit for 19” Chassis (2U)
SV8100
Table 1-2 Chassis Installation Equipment List
Equipment Name
Equipment Description
Product Code
CHS2U BLANK SLOT COVER
KIT
Blank Slot Cover Set
SV8100
CHS2U JOINT BRACKET KIT
Upper Joint Bracket for 6-slot Chassis
SV8100
CHS2U RACK MOUNT KIT
Rack Mount for CHS2U Chassis
SV8100
CHS1U/2U WALL MOUNT KIT Wall Mount Set for CHS2U Chassis
SV8100
CHS Stand Kit (K)
Stand Mount Kit for 2U Chassis
SV8100
Table 1-3 Battery Mount Equipment List
Equipment Name
Equipment Description
Product Code
CHS1U BATT MTG KIT-A
Built-in Battery Mount Kit (for 1U Chassis)
for GS Yuasa PE12V-0.8 batteris (AMP
connectors) or GS Yuasa NP0.8-12
batteries (JST connectors)
SV8100
CHS1U BATT CA INT KIT
(GS-NP)
Cable set for internal battery
SV8100
CHS LARGE BATT BOX
Long Term Battery Box for CHS1U and
CHS2U Chassis
SV8100
CHS BATT CA EXT-A
Cable set for external battery
SV8100
CHS2U BATT MTG KIT
Battery Mount for CHS2U Chassis
SV8100
System Hardware Manual
1 - 5
Table 1-4 Blade Equipment List
Equipment Name Abbreviations
Equipment Description
Product Code
CD-CP00
CPU
Main Processor Blade for KTS
SV8100
PZ-BS10
BUS0
Expansion Chassis Interface Unit, 3-jack
SV8100
PZ-BS11
BUS1
Expansion Chassis Interface Unit, 1-jack
SV8100
PZ-VM21
VMDB
16 Channels for Voice Mail with a Single
Channel V34 Modem
SV8100
PZ-32IPLA
VoIPDB
32-channel VOIP on CCPU
SV8100
PZ-64IPLA
VoIPDB
64-channel VOIP on CCPU
SV8100
PZ-128IPLA
VoIPDB
128-channel VOIP on CCPU
SV8100
CD-8DLCA
DLC
8-port Digital Station Interface
SV8100
PZ-8DLCB
DLCDB
8-port Digital Station Interface on
CD-8DLCA
SV8100
CD-16DLCA
DLC
16-port Digital Station Interface
SV8100
CD-4COTA
COT
4-port Loop Start Trunks
SV8100
PZ-4COTE
COTDB
4-port Loop Start Trunks on CD-4COTA
SV8100
CD-4LCA
LC
4-port Single Line Telephone Interface
SV8100
PZ-4LCA
LCDB
4-port Single Line Telephone Interface on
CD-4LCA and CD-8LCA
SV8100
CD-8LCA
LC
8-port Single Line Telephone Interface
SV8100
PZ-8LCE
LCDB
8-port Single Line Telephone Interface on
CD-4LCA and CD-8LCA
SV8100
CD-2BRIA
BRT
2 Basic Rate Interface
SV8100
PZ-2BRIA
BRTDB
2 Basic Rate Interface on CD-2BRIA
SV8100
CD-PRTA
PRT
1 Primary Rate Interface
SV8100
CD-4DIOPB
DIOP
4 DID/OPX
SV8100
CD-4ODTA
ODT
4-port Tie Line Interface (E&M)
SV8100
CD-RTB
RTB
Router (Future)
SV8100
CD-ETIA
GSWU
PoE Gigabit Switch Unit
SV8100
PZ-ME50
MEM
Memory Expansion on CD-CP00
SV8100
CD-LTA
LTA
8 Digital Station/2SLT for CD-CP00 only
SV8100
CD-PVAA
CNF
Packet Voice Application (Future)
SV8100
1 - 6
Introduction to SV8100
Table 1-5 Cable Equipment List
Equipment Name
Equipment Description
Product Code
RS CONSOLE CA-A
MAT (PCPro) Cable 6.6 ft. (2.0m)
SV8100
RS NORM-4S CA-F
RS-232C Cable (normal) 13.1 ft (4m)
SV8100
RS RVS-15S CA-F
RS-232C Cable (reverse) 49.2 ft (15.0m)
SV8100
RS RVS-4S CA-F
RS 232C Cable (reverse) 13.1 ft (4.0m)
SV8100
RS RVS-4S CA-G
RS 232C Cable (reverse) 13.1 ft (4.0m)
SV8100
RS PRT-15S CA-F
RS-232C Cable (printer) 49.2 ft (15.0m)
SV8100
BUS CABLE
Bus Cable
SV8100
AC CORD
AC Power Cable for US
SV8100
CHS2U BATT CA INT
CHS2U Battery Cable for Internal Battery
SV8100
CHS2U BATT CA EXT-A
Battery Cable for External Battery 6-slot
Chassis
SV8100
Table 1-6 Digital Multiline Terminal (DT300 Series) Equipment List
Equipment Name
Equipment Description
Product Code
DTL-2E-1 (BK) TEL
Economy Digital 2-button Telephone
(No-Display)
SV8100
DTL-6DE-1 (BK) TEL
Economy Digital 6-button Display
Telephone
SV8100
DTL-12D-1 (BK) TEL
DTL-12D-1 (WH) TEL
Value Digital 12-button Display Telephone
SV8100
DTL-24D-1 (BK) TEL
DTL-24D-1 (WH) TEL
Value Digital 24-button Display Telephone
SV8100
DTL-32D-1 (BK) TEL
DTL-32D-1 (WH) TEL
Value Digital 32-button Display Telephone
SV8100
DTL-12BT-1 (BK) TEL
12D + BCH (Future)
SV8100
DTL-12PA-1 (BK) TEL
Value Digital 12-button Telephone with
Power Failure Adapter
SV8100
DTL-8LD-1 (BK) TEL
DTL-8LD-1 (WH) TEL
Value Digital 8-button Telephone
(DESI-less)
SV8100
DCL-60-1 (BK) CONSOLE
DCL-60-1 (WH) CONSOLE
60-button Direct Station Selection (DSS)
Console
SV8100
System Hardware Manual
1 - 7
8LK-L (BK) UNIT
8LK-L (WH) UNIT
8-button Line Key Unit
SV8100
8LKD (LD)-L (BK) UNIT
8LKD (LD)-L (WH) UNIT
DESI-less 8-button Line Key Unit/LCD Unit
for Digital Telephone
SV8100
Table 1-7 IP Multiline Terminal (DT700 Series) Equipment List
Equipment Name
Equipment Description
Product Code
ITL-2E-1 (BK) TEL
Economy IP 2-button Telephone (No
Display)
SV8100
ITL-6DE-1 (BK) TEL
Economy IP 6-button Display Telephone
SV8100
ITL-12D-1 (BK) TEL
ITL-12D-1 (WH) TEL
Value IP 12-button Display Telephone
SV8100
ITL-24D-1 (BK) TEL
ITL-24D-1 (WH) TEL
Value IP 24-button Display Telephone
SV8100
ITL-32D-1 (BK) TEL
ITL-32D-1 (WH) TEL
Value IP 32-button Display Telephone
SV8100
ITL-12PA-1 (BK) TEL
Value IP 12-button Telephone with Power
Failure Adapter
SV8100
ITL-8LD-1 (BK) TEL
ITL-8LD-1 (WH) TEL
Value IP 8 Line Key Display Telephone
Value IP Telephone: DESI-less
SV8100
ITL-320C-1 (BK) TEL
Sophisticated Telephone
SV8100
8LKI (LD)-L (BK) UNIT
8LKI (LD)-L (WH) UNIT
DESI-less LK/LCD Unit for IP
SV8100
Table 1-8 DT300/DT700 Series Optional Equipment List
Equipment Name
Equipment Description
Product Code
APR-L UNIT
APR
SV8100
ADA-L UNIT
ADA
SV8100
BHA-L UNIT
Bluetooth® Hub Adapter (Future)
SV8100
PSA-L (BK) UNIT
PSA-L (WH) UNIT
PSA
SV8100
BCH-L (BK) UNIT
Bluetooth Cordless Handset (Future)
SV8100
Table 1-6 Digital Multiline Terminal (DT300 Series) Equipment List (Continued)
Equipment Name
Equipment Description
Product Code
1 - 8
Introduction to SV8100
12LK-L (BK) KIT
12LK-L (WH) KIT
12-button Line Key Kit
SV8100
LCD (BL)-L (BK) UNIT
LCD (BL)-L (WH) UNIT
LCD Unit (No Backlight)
SV8100
WM-L UNIT
Wall Mount Unit
SV8100
DESI ITL/DTL-2E (25 PKG)
DESI Sheet for Economy 2-button
Telephone (2 Labels per Sheet)
SV8100
DESI ITL/DTL-6DE (25 PKG) DESI Sheet for Economy 6-button Display
Telephone (2 Labels per Sheet)
SV8100
DESI ITL/DTL-12D (25 PKG) DESI Sheet for Value 12-button Display
Telephone (2 Labels per Sheet)
SV8100
DESI ITL/DTL-8LK (25 PKG) DESI Sheet for 8-button Line Key (2 Labels
per Sheet)
SV8100
DESI DCL-60 (25 PKG)
DESI Sheet for 60DSS (1 Label per Sheet)
SV8100
DESI ITL/DTL-SIDE(25
PKG)
DESI Sheet for Clear Side Panel (Left and
Right Label each Sheet)
SV8100
DESI ITL/DTL-SIDE-
LCDV(25 PKG)
DESI Sheet for Value Telephone LCD
(Clear Side)
SV8100
DESI ITL/DTL-SIDE-
LCDS(25 PKG)
DESI Sheet for Sophisticated Telephone
LCD (Clear Side)
SV8100
DESI ITL/DTL Directory Card Directory Card
SV8100
DESI ITL/DTL-24D (25 PKG) DESI Sheet for Value 24-button Display
Telephone (2 Labels per Sheet)
SV8100
Panel (Red-Base)-L UNIT
Color Side Panel for Base (Red)
SV8100
Panel (Red-VLCD)-L UNIT
Color Side Panel for Value Telephone LCD
(Red)
SV8100
Panel (Red-SLCD)-L UNIT
Color Side Panel for Sophisticated
Telephone LCD (Red)
SV8100
Panel (Blue-Base)-L UNIT
Color Side Panel for Base (Blue)
SV8100
Panel (Blue-VLCD)-L UNIT
Color Side Panel for Value Telephone LCD
(Blue)
SV8100
Panel (Blue-SLCD)-L UNIT
Color Side Panel for Sophisticated
Telephone LCD (Blue)
SV8100
Panel (Silver-Base)-L UNIT
Color Side Panel for Base (Silver)
SV8100
Panel (Silver-VLCD)-L UNIT
Color Side Panel for Value Telephone LCD
(Silver)
SV8100
Panel (Silver-SLCD)-L UNIT
Color Side Panel for Sophisticated
Telephone LCD (Silver)
SV8100
Table 1-8 DT300/DT700 Series Optional Equipment List (Continued)
Equipment Name
Equipment Description
Product Code
System Hardware Manual
1 - 9
Panel (Wood-Base)-L UNIT
Color Side Panel for Base (Wood)
SV8100
Panel (Wood-VLCD)-L UNIT
Color Side Panel for Value Telephone LCD
(Wood)
SV8100
Panel (Wood-SLCD)-L UNIT
Color Side Panel for Sophisticated
Telephone LCD (Wood)
SV8100
Panel( Logo-Base)-L UNIT
Color Side Panel for Base (Wood with
Logo)
SV8100
Panel (Clear-Base)-L UNIT
Color Side Panel for Base (Clear)
SV8100
LKPANEL(2BTN)-L (BK)
UNIT
Spare Plastic Cover Kit (2-button) (BK)
SV8100
LKPANEL(6BTN)-L (BK)
UNIT
Spare Plastic Cover Kit (6-button) (BK)
SV8100
LKPANEL(12BTN)-L (BK)
UNIT
LKPANEL(12BTN)-L (WH)
UNIT
Spare Plastic Cover Kit (12-button)
SV8100
LKPANEL(24BTN)-L (BK)
UNIT
LKPANEL(24BTN)-L (WH)
UNIT
Spare Plastic Cover Kit (24-button)
SV8100
LKPANEL(8BTN)-L (BK)
UNIT
LKPANEL(8BTN)-L (WH)
UNIT
Spare Plastic Cover Kit (8-button)
SV8100
LKPANEL(60BTN)-L (BK)
UNIT
LKPANEL(60BTN)-L (WH)
UNIT
Spare Plastic Cover Kit (60-button)
SV8100
DTL (Value)-Base-1 unit
Digital Base
SV8100
LCDD(S)-L (BK) UNIT
LCDD(S)-L (WH)) UNIT
Digital Standard Telephone LCD
SV8100
TENKEY(STD)-L SET
Standard 10-Key
SV8100
FNCKEY(STD)-L (BK) SET
FNCKEY(STD)-L (WH) SET
Standard Function Key
SV8100
12LKSoft-L (BK) SET
12LKSoft-L (WH) SET
12LK without Soft Key
SV8100
12LK(STD)-L (BK) SET
12LK(STD)-L (WH) SET
12LK
SV8100
Table 1-8 DT300/DT700 Series Optional Equipment List (Continued)
Equipment Name
Equipment Description
Product Code
1 - 10
Introduction to SV8100
TKPANEL(STD)-L (BK) UNIT
TKPANEL(STD)-L (WH)
UNIT
10-Key Panel
SV8100
Cradle (STD)-L(BK)
Cradle (STD)-L(WH)
Cradle
SV8100
VAL DIRECTORY CARD
UNIT(L)
Directory Card Holder for Value Telephone
SV8100
ECO DIRECTORY CARD
UNIT(L)
Directory Card Holder for Economy
Telephone
SV8100
Panel (Clear-VLCD)-L UNIT
Color Side Panel for Value Telephone LCD
(Clear)
SV8100
Panel (Clear-SLCD)-L UNIT
Color Side Panel for Sophisticated
Telephone LCD (Clear)
SV8100
LKPANEL(16BTN)-L (BK)
UNIT
LKPANEL(16BTN)-L (WH)
UNIT
Spare Plastic Cover Kit (16-button)
SV8100
KeyKitPanel (Value) (BK)
Unit
KeyKitPanel (Value) (WH)
Unit
Spare Plastic Cover Key Kit for Value
Telephone
SV8100
KeyKitPanel (Retro) (BK)
Unit
KeyKitPanel (Retro) (WH)
Unit
Spare Plastic Cover Key Kit for Retro
Telephone
SV8100
KeyKitPanel (Sophi) (BK)
Unit
KeyKitPanel (Sophi) (WH)
Unit
Spare Plastic Cover Key Kit for
Sophisticated Telephone
SV8100
BS (F)-L (BK) KIT
BS (F)-L (WH) KIT
French Keypad
SV8100
BS (S)-L (BK) KIT
BS (S)-L (WH) KIT
Spanish Keypad
SV8100
ITL-GigADP-1
Gigabit Adapter (Future)
SV8100
Table 1-8 DT300/DT700 Series Optional Equipment List (Continued)
Equipment Name
Equipment Description
Product Code
System Hardware Manual
2 - 1
Chapter
2
SV8100 System Specifications
SECTION 1
GENERAL INFORMATION
This chapter provides detailed specifications for the SV8100 system
technician. The technician should review this information carefully before
installing the system.
SECTION 2
SYSTEM BLOCK DIAGRAM
Figure 2-1 SV8100 System Block Diagram shows the Blades that can be
installed in the chassis and the number of channels supported when the
Blade is installed. Table 2-1 List of Abbreviations lists abbreviations used
in the diagram.
Table 2-1 List of Abbreviations
Abbreviation
Description
ACD
Automatic Call Distribution
ADA
Analog Recording Adapter
APR
Analog Port Adapter (with ringer)
BCH
Bluetooth Cordless Handset
BHA
Bluetooth Hub Adapter
AUX IN/OUT
BGM/MOH Port (on CPU)
BRI
Basic Rate Interface
BRIDB
Expansion Basic Rate Interface Blade on BRI
BRT
Basic Rate Interface Blade/ISDN Terminal Interface Blade
BUS0
BUS Interface Blade (for 1U chassis)
BUS1
BUS Interface Blade (for 2U chassis)
CCT
CCIS Interface Blade
CF
Compact Flash
CFT
Conference Trunk (on CPU)
2 - 2
SV8100 System Specifications
CNF
Conference Bridge Blade (PVA)
CPU
Central Processing Unit
DID
Direct Inward Dialing
DIOP
DID/OPX Blade
DLC
Digital Multiline Terminal Interface Blade
DLCB
Expansion Digital Multiline Terminal Interface Blade on DLC
DRS
Device Registration Server (on CPU)
DSS
Direct Station Selection Console
DTI
Digital Trunk Interface
DTG
Digital Tone Generator (on CPU)
ETHERNET
Ethernet Port (on CPU)
FT1
Fractional T1
GSWU
Power over Ethernet Gigabit Switch
IDF
Intermediate Distribution Frame
IPT
IP Trunk (P2P CCIS) (on CPU)
ISDN
Integrated Service Digital Network
LAN
Local Area Network
LC
Single Line Telephone Interface Blade
LCDB
Expansion Single Line Telephone Interface Blade on LC
MDF
Main Distribution Frame
MEM
Main Memory (on CPU)
MIS
Management Information System
MOH
Music On Hold
OAI
Open Application Interface (on CPU)
ODT
Tie Line Interface Blade (2W/4W E&M)
OPX
Off-Premise Extension
PBR
PB Receiver (on CPU)
PBSND
PB Sender (on CPU)
PCPro
PC Programming
Table 2-1 List of Abbreviations (Continued)
Abbreviation
Description
System Hardware Manual
2 - 3
PFT
Power Failure Transfer
PLO
Phase Locked Oscillator (on CPU)
PMS
Property Management System
PRI
Primary Rate Interface
PRT
Primary Rate Interface Blade
PS
Personal Station
PSA
PSTN Adapter (analog)
PVA
Packet Voice Application
RTB
Router Blade
SERIAL
Serial Port (on CPU)
SLT
Single Line Telephone
SMDR
Station Message Detail Recording
TDSW
Time Division Switch (on CPU)
USB
Universal Serial Bus (on CPU)
VM00
UMS Blade Server Blade (SV8100 only)
VMDB
VMS Daughter Board with V34 Modem (SV8100 only)
VMS
Voice Mail System
VoIP
Voice over Internet Protocol
VoIPDB
VoIP Blade (on CPU)
VRS
Voice Response System
WAN
Wide Area Network
WebPro
Web-Based PC Programming
Table 2-1 List of Abbreviations (Continued)
Abbreviation
Description
2 - 4
SV8100 System Specifications
Figure 2-1 SV8100 System Block Diagram
System Hardware Manual
2 - 5
SECTION 3
MAXIMUM SYSTEM CAPACITIES
The CHS2U is a compact 19” chassis that has six universal slots, one expansion slot
and one MPS7101 (power supply unit). When the CD-CP00 is installed in the first
CHS2U, it is referred to as the Controlling Chassis. Additional chassis, referred to as
Expansion Chassis, can be installed to increase the capacity of the system to meet
the customer’s business needs.
As Figure 2-2 19” Controlling and Expansion Chassis and Table 2-2 SV8100
Maximum System Capacities – Trunks/Ports/Channels illustrate, the system can be
expanded from 104 ports to 512 ports by vertically stacking a maximum of three
additional chassis onto the controlling chassis. This provides a maximum of 24 slots
and 320 digital terminals. To obtain a the maximum port capacity of 512 ports, two
systems can be linked together via an IP connection.
The maximum slot and channel capacities are listed in Table 2-2 SV8100 Maximum
System Capacities – Trunks/Ports/Channels.
Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels
Number of:
19” Chassis
System
Maximum
x 1
(6 Slots)
x 2
(12 Slots)
x 3
(18 Slots)
X4
(24 Slots)
Number of Timeslots
111
222
333
444
444
Number of TDM (Time Division Multiplexing)
Ports
104
208
312
416
416
Dterm (-48V) *1
80
160
240
320
Total 512
SLT (-24V)
80
176
272
368
SLT (-48V)
20
44
68
92
DtermIP
512
SIP/WLAN
512
Analog Trunks (COT)
40
88
136
184
Total 200
BRI
40
88
136
184
PRI
90
180
180
180
IP Trunk (SIP)
200
VoIP Channels
128
2 - 6
SV8100 System Specifications
3.1
System Configuration – SV8100
The SV8100 19” chassis provides 104 total ports (80 digital terminals) and can
be expanded, using three additional 19” chassis, for a maximum of 416 ports
(320 digital terminals). Through IP connection and use of additional 19”
chassis, the system can be expanded to a maximum of 512 ports.
The 19” chassis consists of a controlling chassis (chassis with CPU blade),
and the ability to expand the system using expansion blades depending on
system configuration.
Voice Mail Channels on CPU
16 channels
V90 Modem
1 channel
*1 = Maximum 80 Digital Terminals per 19” chassis due to power consumption
Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels
Number of:
19” Chassis
System
Maximum
x 1
(6 Slots)
x 2
(12 Slots)
x 3
(18 Slots)
X4
(24 Slots)
System Hardware Manual
2 - 7
Figure 2-2 19” Controlling and Expansion Chassis
6 Slots
18 Slots
IP Connection
24 Slots
2 - 8
SV8100 System Specifications
Table 2-3 Maximum System Capacities – Chassis shows the maximum number of
chassis and related equipment that can be installed in a system.
Table 2-3 Maximum System Capacities – Chassis
Hardware
19”
Chassis
with CPU
19”
Chassis
without
CPU
19”
Chassis
x4
Comments
Number of Slot(s) for Interface
Package
5 Slots
6 Slots
23 Slots
Chassis:
CHS2U
(19” Chassis)
1
3
4
Virtual slot in
NetLink is limited to
maximum of 240
Expansion:
PZ-BS10
3-jack Expansion Board for
Controlling Chassis
1
0
0
–
PZ-BS11
1-jack Expansion Board for
Expansion Chassis
0
1
3
–
Battery:
CHS LARGE BATT BOX
(External Battery Box)
1
1
4
–
Fan Box:
CHS2U FAN BOX SET
1
1
4
1 is factory
installed with each
chassis
Power Supply:
MPS7101
1
2
4
1 is factory
installed with each
chassis
System Hardware Manual
2 - 9
Table 2-4 Maximum System Capacities – Blades shows the maximum number for
each blade that can be installed in a system.
This is determined by the maximum blade configuration allowed. When installing
single line sets, DISA, or tie lines, CPU circuits must be allocated for DTMF receivers.
To install single line sets with CO/PBX line access, or when installing immediate-start
tie lines, CPU circuits must be allocated for dial tone detection.
Table 2-4 Maximum System Capacities – Blades
Hardware
19”
Chassis
with CPU
19”
Chassis
without
CPU
19”
Chassis
x4
Comments
Number of Slot(s) for Interface
Package
5 Slots
6 Slots
23 Slots
Common Control Blades:
CD-CP00
1
0
0
–
PZ-32IPLA
(32-port VoIP Daughter Board)
1
0
0
This unit provides 32 VOIP
Gateway channels
PZ-64IPLA
(64-port VoIP Daughter Board)
1
0
0
This unit provides 64 VOIP
Gateway channels
PZ-128IPLA
(128-port VoIP Daughter Board)
1
0
0
This unit provides 128 VOIP
Gateway channels
PZ-ME50
(Memory Expansion Board)
1
0
0
–
PZ-VM21
(Voice Mail Daughter)
1
0
0
Does include modem
Station Blades:
CD-4DIOPB
(4 DID/OPX)
5
6
23
When installed as an OPX blade
CD-4LCA
(4 Single Line Telephone Interface)
5
6
23
–
PZ-4LCA
(4 Single Line Telephone Interface
Daughter Board)
5
6
23
–
CD-8DLCA
(8 Digital Station Interface)
5
6
23
Maximum of 80 Digital Terminals
per chassis
PZ-8DLCB
(8 Digital Station Interface Daughter
Board)
5
5
20
Maximum of 80 Digital Terminals
per chassis
2 - 10
SV8100 System Specifications
CD-8LCA
(8 Single Line Telephone Interface)
5
6
23
Maximum of 80 Analog Terminals
per chassis
PZ-8LCE
(8 Single Line Telephone Interface
Daughter Board)
5
5
20
Maximum of 80 Digital Terminals
per chassis
CD-16DLCA
(16 Digital Station Interface)
5
5
20
Maximum of 80 Analog Terminals
per chassis
CD-LTA
(8 Digital/2 Single Line)
1
1
4
An optional PZ-4COTE or
PZ-2BRIA can be installed
Trunk Blades:
CD-2BRIA
(2 Basic Rate Interface)
5
6
23
–
PZ-2BRIA
(2 Basic Rate Interface Daughter
Board)
5
6
23
–
CD-4COTA
(4 Loop Start Trunk)
5
6
23
–
PZ-4COTE
(4 Loop Start Trunk Daughter Board)
5
6
23
–
CD-4DIOPB
(4 DID/OPX)
5
6
23
When installed as a DID blade
CD-4ODTA
(4 E&M)
5
6
23
–
CD-PRTA
(1 Primary Rate Interface)
3
3
6
This blade is used for Primary Rate
Interface.
Optional Blades:
CD-PVAA
(Conference Bridge)
5
6
23
R2
CD-ETIA
(Switching Hub with Power over
Ethernet)
3
3
12
–
CD-RTB
(Router)
1
2
1
R2
Table 2-4 Maximum System Capacities – Blades (Continued)
Hardware
19”
Chassis
with CPU
19”
Chassis
without
CPU
19”
Chassis
x4
Comments
Number of Slot(s) for Interface
Package
5 Slots
6 Slots
23 Slots
System Hardware Manual
2 - 11
PZ-BZ10 (for Controlling Chassis)
1
0
0
–
PZ-BZ11 (for Expansion Chassis)
0
1
3
–
Table 2-4 Maximum System Capacities – Blades (Continued)
Hardware
19”
Chassis
with CPU
19”
Chassis
without
CPU
19”
Chassis
x4
Comments
Number of Slot(s) for Interface
Package
5 Slots
6 Slots
23 Slots
2 - 12
SV8100 System Specifications
Table 2-5 Daughter Board Combinations shows each blade and associated daughter
board combinations. The daughter boards that can be mounted on specific blades
are indicated by a checkmark. For example, the CD-LTA can have a PZ-2BRIA or the
PZ-4COTE daughter board mounted.
Table 2-5 Daughter Board Combinations
Daughter Board
PZ-2BRIA PZ-4COTE
PZ-4LCA
PZ-8LCE
PZ-8DLCB
Controlling Chassis
CD-LTA
(8 Digital/2 Single Line)
4
4
–
–
–
CD-4COTA
(4 Loop Start)
–
4
–
–
–
CD-4LCA
(4 Single Line Interface)
–
–
4
4
–
CD-8LCA
(8 Single Line Interface)
–
–
4
4
–
CD-8DLCA
(8 Digital Station Interface)
–
–
–
–
4
CD-16DLCA
(16 Digital Station Interface)
–
–
–
–
–
CD-2BRIA
(2 Basic Rate Interface)
4
–
–
–
–
– = Does not apply
4 = Does apply
System Hardware Manual
2 - 13
SECTION 4
POWER-BASED CALCULATOR CHART
The Univerge SV8100 system uses two types of power factors. For a single chassis
chart refer to Table 2-6 Board Power Factor. For the maximum number of specific
blades per package, see Table 2-7 Maximum Number of Package Installed. Refer to
Table 2-8 Terminal Power Factor below, for the Terminal/ Adapter power chart.
Table 2-6 Board Power Factor
Board Power Factor
Total =<7
Item
Power Factor
CD-CP00
1
CD-RTB
2
CD-VM00
2
CD-ETIA
2
CD-PVAA
1
PZ-32IPLA
1
PZ-64IPLA
2
PZ-128IPLA
2
Table 2-7 Maximum Number of Package Installed
Board
(Power Factor)
Maximum Number of Package
Installed
19 inch
with CCPU
19 inch
without
CCPU
4 x 19 inch
CD-ETIA (2)
3
3
12
CD-PVAA (1)
5
6
23
CD-RTB (2)
2
2
8
2 - 14
SV8100 System Specifications
Table 2-8 Terminal Power Factor
Terminal Power Factor
19 inch Chassis =<80
Item
Power Factor
DTL-24D-1 TEL
1
DTL-8LD-1 TEL
1.5
BHA-L Unit
2
ADA-L UNIT
2
APR-L UNIT
2
BCH-L (BK) UNIT
2
Power Save Adapter
1
8LK-L UNIT
0
DCL-60-1 CONSOLE
2
ITL-320C-1 TEL
6
ITL-24D-1 TEL
4
ITL-2E-1 TEL
4
ITL-6DE-1 TEL
4
SLT
1
PGD(2)-U10 ADP
2
SLT Adapter
5
.
ITL factors are calculated using the CD-ETIA blade.
Table 2-9 IP Terminal Power Chart
IP
Terminal
IEEE802.
3af
Class
Label Indication
(Maximum Current with All Options)
Maximum Current Without Options
48VDC
24VDC
48VDC
24VDC
ITL-320C-1 TEL
Class 3
160mA
7.7W
290mA
7.0W
111mA
5.3W
192mA
4.6W
ITL-32D-1 TEL
Class 2
130mA
6.2W
235mA
5.6W
90mA
4.3W
153mA
3.7W
ITL-8LD-1 TEL
Class 2
130mA
6.2W
235mA
5.6W
81mA
3.9W
137mA
3.3W
System Hardware Manual
2 - 15
ITL-24D-1 TEL
Class 2
130mA
6.2W
235mA
5.6W
81mA
3.9W
137mA
3.3W
ITL-12D-1 TEL
Class 2
130mA
6.2W
235mA
5.6W
81mA
3.9W
137mA
3.3W
ITL-24PA-1 TEL
Class 2
130mA
6.2W
235mA
5.6W
–
0.0W
–
0.0W
ITL-24PD-1 TEL
Class 2
130mA
6.2W
235mA
5.6W
–
0.0W
–
0.0W
ITL-24BT-1 TEL
Class 2
130mA
6.2W
235mA
5.6W
–
0.0W
–
0.0W
ITL-6DE-1 TEL
Class 1
68mA
3.3W
122mA
2.9W
68mA
3.3W
122mA
2.9W
ITL-2E-1 TEL
Class 1
68mA
3.3W
122mA
2.9W
68mA
3.3W
122mA
2.9W
Label Indication:
IP Value/Sophisticated – Maximum watts when adding options or modular upgrades.
IP Value – Maximum watts when ITL-12D-1 TEL is changed to ITL-8LD-1 TEL or ITL-24D-1 TEL.
Table 2-9 IP Terminal Power Chart (Continued)
IP
Terminal
IEEE802.
3af
Class
Label Indication
(Maximum Current with All Options)
Maximum Current Without Options
48VDC
24VDC
48VDC
24VDC
Table 2-10 IEEE802.af Class Specifications
IEEE802.3af
Minimum
Maximum
Class 4
–
–
Class 3
6.49W
12.95W
Class 2
3.84W
6.49W
Class 1
0.44W
3.84W
Class 0
0.44W
12.95W
2 - 16
SV8100 System Specifications
SECTION 5
SYSTEM REQUIREMENTS AND SPECIFICATIONS
5.1
Cabling
This section provides cabling requirements and specifications for various
equipment used in the SV8100 system.
Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable is a diagram of the
chassis connected with each of the multiline terminals and single line
telephones by a separate twisted 1-pair cable or 2-pair cable (only for Multiline
Terminals).
Refer to the following tables for cabling requirements and specifications.
�
Table 2-11 DT300 Series Loop Resistance and Cable Length
�
Table 2-12 DT700 Series Loop Resistance and Cable Length
�
Table 2-13 Dterm Series i or Dterm IP Terminal Loop Resistance and Cable
Length
�
Table 2-14 Cable Connection Between the Analog Port and the Single Line
Equipment
�
Table 2-15 Cabling Requirements
Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable
Table 2-11 DT300 Series Loop Resistance and Cable Length
Terminal or Adapter
By Twisted 1-Pair
Cable (without
AC Adapter)
24 AWG
DTL-2E-1 (BK) TEL
1,969 ft (600m)
DTL-6DE-1 (BK) TEL
1,969 ft (600m)
DTL-8LD-1 (BK) TEL
DTL-8LD-1 (WH) TEL
1,969 ft (600m)
DTL-12BT-1 (BK) TEL
1,969 ft (600m)
DTL-12PA-1 (BK) TEL
1,969 ft (600m)
DTL-12D-1 (BK) TEL
DTL-12D-1 (WH) TEL
1,969 ft (600m)
Multiline Terminal
Twisted 2-Pair Cable
DLC
RJ-11
System Hardware Manual
2 - 17
DTL-24D-1(BK) TEL
DTL-24D-1(WH) TEL
1,969 ft (600m)
DTL-32D-1 (BK) TEL
DTL-32D-1 (WH) TEL
1,969 ft (600m)
DCL-60-1 Console*
1,969 ft (600m)
* An AC Adapter is required.
Table 2-12 DT700 Series Loop Resistance and Cable Length
Terminal or Adapter
Ethernet Cable
ITL-2E-1 (BK) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-6DE-1 (BK) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-8LD-1 (BK) TEL
ITL-8LD-1 (WH) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-12BT-1 (BK) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-12D-1 (BK) TEL
ITL-12D-1 (WH) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-12PA-1 (BK) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-24D-1 (BK) TEL
ITL-24D-1 (WH) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100 m)
ITL-32D-1 (BK) TEL
ITL-32D-1 (WH) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
ITL-32OC-1 (BK) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
Table 2-11 DT300 Series Loop Resistance and Cable Length (Continued)
Terminal or Adapter
By Twisted 1-Pair
Cable (without
AC Adapter)
24 AWG
2 - 18
SV8100 System Specifications
Table 2-13 Dterm Series i or Dterm IP Terminal Loop Resistance and Cable Length
Terminal or
Adapter
Maximum
Loop
Resistance
(without AC
Adapter)
(Ohms)
By Twisted
1-Pair Cable
(without AC
Adapter)
24 AWG
By Twisted
2-Pair Cable
(without AC
Adapter)
24 AWG
Maximum
Loop
Resistance
(with AC
Adapter)
(Ohms)
By Twisted
1-Pair Cable
(with AC
Adapter)
24 AWG
By Twisted
2-Pair Cable
(with AC
Adapter)
24 AWG
DTH-8-1 TEL
DTR-8-1 TEL
37
700
1400
107
2000
2000
DTH-8D-1 TEL
DTR-8D-1 TEL
37
700
1400
107
2000
2000
DTH-16-1 TEL
DTR-16-1 TEL
35
660
1320
107
2000
2000
DTH-16D-1 TEL
DTR-16D-1 TEL
35
660
1320
107
2000
2000
DTH-32D-1 TEL
DTR-32D-1 TEL
26
500
1000
107
2000
2000
DTH-16LD-1 TEL
37
700
1400
107
2000
2000
DCR-60-1 Console*
—
—
—
107
2000
2000
* An AC Adapter is required.
Table 2-14 Cable Connection Between the Analog Port and the Single Line Equipment
Connected Equipment
Cable
Maximum Feet from Connected
Equipment to Telephone
ADA-L UNIT
Twisted Pair
10 ft (3.048m)
APR-L UNIT
Twisted Pair
50 ft (15.24m)
PSA-L (BK) UNIT
Twisted Pair
1,700 ohms
PSA-L (WH) UNIT
Twisted Pair
1,700 ohms
.
Mixing digital and analog ports through the same 25-pair cable runs is not
recommended.
System Hardware Manual
2 - 19
5.2
Power Requirements
A dedicated 230VAC 50 Hz circuit located within seven feet of the chassis is
required. A separate dedicated outlet for each chassis should be installed.
5.2.1
Power Supply Specifications
AC Power Supply:
�
Dedicated 15 Amp circuit
�
Power Requirements: 230 VAC @ 15A Controlling/Base Chassis
�
Power Consumption: Base Chassis=265VA, Expansion
Chassis=265VA, total 1060VA
�
Input Voltage: 90VAC to 264VAC
(Rated Voltage: 100VAC/120VAC/220VAC - 240VAC)
�
Frequency: 45Hz - 66Hz (Rated frequency: 50/60Hz)
�
Phase and Wire: Single Phase, 2 Line + PE Type
�
Grounding Requirements: No. 14 AWG copper wire
�
Feeding Voltage: Dterm/OPX/DID: -48V
SLT: 25mA / -28V
With input voltage of 230 VAC and with full load conditions:
Output Power: Base chassis=130W, Expansion chassis=130W, total
520W
AC Input I: Base chassis=1.15A, Expansion chassis=1.15A, total 4.6A
VA @ 220V: Base chassis=265VA, Expansion chassis=265VA, total
1060VA
Table 2-15 Cabling Requirements
Connected Equipment
Cable
Music on Hold and Background Music Sources
Hi-Fi Shielded Audio Cable
External Amplifier
Hi-Fi Shielded Audio Cable
ITL Cabling
Cat 5 Straight Data Network
Cable – 328.1 ft (100m)
maximum distance.
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N side).
2 - 20
SV8100 System Specifications
KWh @ AC Input I x 230V/1000: Base chassis=0.265 KWh,
Expansion chassis=0.265 KWh, total 1.060 KWh
BTU (KWh x 3413): Base chassis=904 BTU, Expansion chassis=904
BTU, total 3616 BTU
�
Dedicated 230 Vac
�
50/60 Hz circuit located within seven feet of the chassis
�
Dedicated 15A circuit
�
Single Phase
�
A dedicated outlet, separately fused and grounded for each chassis
should be installed
5.2.2
Power Supply Consumption
5.3
Environmental Conditions
5.3.1
Temperature and Humidity
Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR
�
Operating Temperature: 0°C ~ 40°C
�
Recommended Long Term Temperature: -20°C ~ 60°C
�
Operating Humidity: 10 ~ 90% RH (non-condensing)
Table 2-16 Power Consumption
Chassis
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Basic Chassis – CD-CP00 Chassis
1.15 A
96
130
Basic Chassis + Expansion Chassis
2.3 A
192
260
Basic Chassis + 2 Expansion Chassis
3.45 A
288
390
Basic Chassis + 3 Expansion Chassis
4.6 A
384
520
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N
side).
Double Pole/Neutral Fusing
(power supply fuses are located at both the L and N
side).
System Hardware Manual
2 - 21
�
Recommended Long Term Humidity: 10 ~ 90% RH
Blades – PZ-BS10, PZ-BS11, PZ-VM21, PZ-ME50, CD-8DLCA,
CD-16DLCA, PZ-8DLCB
�
Operating Temperature: 0oC ~ 40oC
�
Recommended Long Term Temperature: -20°C ~ 60°C
�
Humidity: 10 ~ 90% RH (non-condensing)
�
Recommended Long Term Humidity: 10 ~ 90% RH
Blades - CD-4LCA, PZ-4LCA, CD-8LCA, PZ-8LCE, CD-4COTA,
PZ-4COTE, CD-PRTA
�
Operating Temperature: 0°C ~ 40°C
�
Recommended Long Term Temperature: -20°C ~ 60°C
�
Operating Humidity: 10 ~ 90% RH (non-condensing)
�
Recommended Long Term Humidity: 20 ~ 90% RH
Door Box
�
Operating Temperature: -20oC ~ 60oC
�
Operating Humidity: 20 ~ 80% (non-condensing)
SV8100 Power Supply – MPS7101
�
Operating Temperature: 0oC ~ +40oC
�
Recommended Long Term Temperature: -40oC ~ 75oC
�
Operating Humidity: 20 ~ 95% RH (non-condensing)
�
Recommended Long Term Humidity: 10 ~ 95% RH
5.4
Outside Line Types
The following outside lines can be used with the UNIVERGE SV8100 system.
�
4-wire, E&M Tie Lines (Type I or V, Dial Pulse, or DTMF)
�
Digital Trunk T1/FT1 (Loop Start, Tie Line (E&M), or DID Signaling)
�
ISDN-BRI Trunks
�
ISDN-PRI Trunks
�
VoIP Trunks (Internet Protocols)
5.5
Transmission, Network, and Control Specifications
5.5.1
Transmission
�
Data Length:
2 - 22
SV8100 System Specifications
From Multiline Terminal to CD-8DLCA: 23 bits
From CD-8DLCA to Multiline Terminal: 23 bits
�
Data Transmission Rates:
Between CD-8DLCA and Multiline Terminal: 184K bps (voice and
signaling)
�
Scanning Time for each Multiline Terminal: 32 ms.
5.5.2
Network
Time Division Multiplexing (TDM) allows transmission of data and
voice simultaneously over one communications medium. The
specifications that the UNIVERGE SV8100 system uses for
switching, clock, data bus, and timeframe are shown below.
�
TDM Switching: PCM (µ Law)
�
TDM Clock: 2.048 MHz
�
TDM Data Bus: 8 bit
�
TDM Timeframe: 125 µs.
5.5.3
Control
This section indicates the speed or capacity:
�
Control: Stored program with distributed processing
�
Central Processor: 32-bit microprocessor
�
Clock: 266 MHz
�
Interface Blade: 8- or 16-bit microprocessor
�
Optional Blades: 16- or 32-bit microprocessor
�
Multiline Terminal (TDM): 8-bit microprocessor
�
Multiline Terminal (IP): 32-bit microprocessor
�
IP Adapter: 32-bit microprocessor
�
Attendant Console: 4-bit microprocessor
�
SLT Adapter: 4-bit microprocessor
System Hardware Manual
2 - 23
5.5.4
Electra Elite IPK Terminals and Equipment
The voltage, current, and ring signal for the Electra Elite IPK Multiline
Terminals, Single Line Telephone equipment, and AP(A)-R/AP(R)-R
Units are listed below:
�
Multiline Terminal
Voltage: -11 ~ -26 Vdc
Maximum Current: 250 mA
�
Single Line Telephone
Standard 2500 Set: 500 type network
Nominal Current: 25 mA
Ring Signal: 56 Vac RMS @ 20 Hz
�
SLTII(1)-U( ) ADP
Standard 2500 Set: 500 type network
Nominal Current: 30 mA
Ring Signal: 56 Vac RMS @ 20 Hz
�
AP(A)-R Unit
Standard 2500 Set: 500 type network
Nominal Current: 30 mA
�
AP(R)-R Unit
Standard 2500 Set: 500 type network
Nominal Current: 30 mA
Ring Signal: 56 Vac RMS @ 20 Hz
Acoustical characteristics meet Electronic Industry
Association (EIA) standard proposal SP-1286 and
standard EIA RS-470.
2 - 24
SV8100 System Specifications
5.5.5
Series i Terminals
�
The voltage and current for the Dterm Series i Multiline Terminals are
listed below:
Voltage: -11 ~ -48 Vdc
Maximum Current: 250 mA
�
Voltage, current, and ring signal information for Single Line Telephone
equipment, AP(A)-R Unit, and AP(R)-R Unit are the same a those listed
in the previous paragraph.
5.6
Dialing Specifications
5.6.1
Dial Pulse Address Signaling
Dial Pulse Address Signaling uses dial pulses (regular momentary
interruptions) to signal the equipment. The following Dial Pulse
specifications are used In the UNIVERGE SV8100 system.
�
Pulse Rate: 10 ± 0.5 pps/20 ± 1.0 pps
�
Percent Break: 60 ± 1.5%
�
Interdigit Interval: 0 pps/20 pps 770 ms. ~ 830 ms.
5.6.2
Dual-Tone Multifrequency (DTMF) Address Signaling
DTMF signaling includes push button or Touchtone dialing. When a
key on a telephone is pushed, two tones (one high frequency and
one low frequency) are provided. In the UNIVERGE SV8100 system,
the following DTMF specifications are used.
�
Frequencies
Two sinusoidal frequencies are provided, one from the high frequency
group and one from the low frequency group.
�
Frequency Deviation: Less than ±1.5%
�
Signal Level:
Nominal level per frequency: -6 ~ -4 dBm
Minimum level per frequency
Low Group: -10 dBm
High Group: -8 dBm
Maximum level per frequency: 0 dBm
Acoustical characteristics meet Electronic Industry
Association (EIA) standard proposal SP-1286 and
standard EIA RS-470.
System Hardware Manual
2 - 25
�
Rise Time: Within 5 ms.
�
Duration of Dual Frequency Signal:
110 ms. default/60 ms. minimum
Interdigital Time: 140 ms. default/45 ms. minimum
5.6.3
External Equipment Connection
�
Door Phone or TV Door Phone
�
External Speaker via amplifier
�
External music source for MOH and BGM
�
Tape recorder for voice recording via PGD(2)-U10 ADP
�
Door Lock/Release or General Purpose Relay via PGD(2)-U10 ADP
�
Printer for SMDR by LAN
�
PC by LAN
5.6.4
Music Source for Music on Hold via Chassis
�
Auxiliary Input: 0.6V PPS Signal Level
�
Input Impedance: 600 Ω
5.6.5
Music Source for Station Background Music via ACI
�
Auxiliary Input: 0.6V PPS Signal Level
�
Input Impedance: 600 Ω
5.6.6
External Paging (Audio)
�
Output Power: –10 dBm Signal Level
�
Output Impedance: 600 Ω
�
Relay Contact Rating: 500 mA, 24 Vdc
1209
1336
1477
697
1
2
3
770
4
5
6
852
7
8
9
941
Q
0
#
Nominal Low Group
Frequencies (Hz)
Nominal High Group
Frequencies (Hz)
2 - 26
SV8100 System Specifications
5.6.7
External Tone Ringer/Night Chime Output
�
Output Level: –10 dBm
�
Output Impedance: 600 Ω
�
Relay Contact Rating: 500 mA, 24 Vdc
5.6.8
SMDR Output
�
Female Connector (LAN) Standard DB-9 (straight)
5.6.9
PC Connection
�
Female Connector (LAN) Standard DB-9 (straight)
5.6.10
Relay Contact
�
All Relay Contact Ratings: 500 mA, 24Vdc
5.7
Battery Backup
The UNIVERGE SV8100 system has battery backup functions for system
backup and for memory backup.
5.7.1
System Backup (Optional)
During a power failure, the system can be backed up using the
CHS2U BATT MTG KIT for a backup time of 10 minutes or one of the
CHS LARGE BATT SETs for a backup time ranging from 45~180
minutes.
5.7.2
Memory Backup
The CD-CP00 Blade battery retains the Clock/Calender and Last
Number redial (LNR) buffers for each station when the CD-CP00
Blade encounters a power loss. With a fully charged battery, the
settings are retained for about three years. The System Programmed
memory (Customer Database) is stored in non-volatile Memory and
can be erased only by a First Initialization. After power is restored,
the system Blade returns to normal operation.
System Hardware Manual
2 - 27
5.8
Weights and Dimensions
Table 2-17 SV8100 Weights and Dimensions on page 2-27 shows the
shipping weight, height, width and depth of each SV8100 digital multiline
terminal, IP multiline terminal, Dterm, Series i multiline terminal, chassis,
assorted blades and adapters.
Table 2-17 SV8100 Weights and Dimensions
Unit
Shipping
Weight 1
Height
Width
Depth
SV8100
CHS2U
278.7 oz
(7.9 kg)
3.47 in
(88 mm)
16.9 in
(430 mm)
14.17 in
(360 mm)
CD-CP00
7.06 oz
(0.2 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.09 in
(180 mm)
PZ-ME50
.353 oz
(0.01 kg)
0.12 in
(3 mm)
2.56 in
(65 mm)
1.22 in
(31 mm)
CD-LTA
6.70 oz
(0.19 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.09 in
(180 mm)
CHS LARGE BATT BOX
352.7 oz
(10 kg)
23.23 in
(590 mm)
17.72 in
(450 mm)
10.43 in
(265 mm)
CHS LARGE BATT SET
194 oz
(5.5 kg)
6.69 in
(170 mm)
5.91 in
(150 mm)
4.33 in
(110 mm)
Common
MPS7101
31.75 oz
(0.9 kg)
2.36 in
(60 mm)
7.08 in
(180 mm)
6.10 in
(155 mm)
PZ-BS10
2.29 oz
(.065 kg)
0.91 in
(23 mm)
2.17 in
(55 mm)
7.28 in
(185 mm)
PZ-BS11
1.975 oz
(0.056 kg)
0.91 in
(23 mm)
2.17 in
(55 mm)
7.28 in
(185 mm)
PZ-VM21
1.76 oz
(0.05 kg)
0.60”
(15 mm)
2.09 in
(53 mm)
3.35 in
(85 mm)
PZ-32IPLA
1.76 oz
(0.05 kg)
0.60 in
(15 mm)
3.15 in
(80 mm)
6.3 in
(160 mm)
PZ-64IPLA
1.76 oz
(0.05 kg)
0.60 in
(15 mm)
3.15 in
(80 mm)
6.3 in
(160 mm)
PZ-128IPLA
1.76 oz
(0.05 kg)
0.60 in
(15 mm)
3.15 in
(80 mm)
6.3 in
(160 mm)
CD-8DLCA
5.89 oz
(0.167 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.09 in
(180 mm)
PZ-8DLCB
4.41 oz
(0.125 kg)
0.60 in
(15 mm)
4.72 in
(120 mm)
5.12 in
(130 mm)
2 - 28
SV8100 System Specifications
CD-16DLCA
7.831 oz
(0.222 kg)
1.89 in
(48 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CD-4COTA
6.35 oz
(0.18 kg)
1.89 in
(48 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
PZ-4COTE
3.53 oz
(0.10 kg)
1.89 in
(48 mm)
9.45 in
(240 mm)
5.12 in
(130 mm)
CD-4LCA
5.99 oz
(0.17 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
PZ-4LCA
3.10 oz
(0.09 kg)
0.60 in
(15 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CD-8LCA
6.46 oz
(0.183 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
PZ-8LCE
3.70 oz
(0.105 kg)
0.60 in
(15 mm)
9.45 in
(240 mm)
5.12 in
(130 mm)
CD-2BRIA
5.99 oz
(0.17 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
PZ-2BRIA
4.02 oz
(0.114 kg)
0.60 in
(15 mm)
4.72 in
(120 mm)
7.68 in
(195 mm)
CD-PRTA
5.5 oz
(0.156 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
3.94 in
(100 mm)
CD-CCTA
5.5 oz
(0.156 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CD-4ODTA
8.25 oz
(0.234 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CD-RTB
12.17 oz
(0.345 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.68 in
(195 mm)
CD-VM00
7.76 oz
(0.22 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CD-PVAA
10.05 oz
(0.285 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.68 in
(195 mm)
CD-ETIA
12.17 oz
(0.345 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.68 in
(195 mm)
CD-4DIOPB
7.73 oz
(0.219 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CHS BASE UNIT
21.87 oz
(0.62 kg)
23.23 in
(590 mm)
17.72 in
(450 mm)
10.43 in
(265 mm)
CHS2U BLANK SLOT COVER KIT
1.76 oz
(0.05 kg)
2.32 in
(60 mm)
1.57 in
(40 mm)
1.57 in
(40 mm)
Table 2-17 SV8100 Weights and Dimensions (Continued)
Unit
Shipping
Weight 1
Height
Width
Depth
System Hardware Manual
2 - 29
CHS L BATT BOX RACK MOUNT BRACKET
352.7 oz
(10 kg)
18.5 in
(470 mm)
14.6 in
(370 mm)
2.76 in
(70 mm)
CHS2U INT BATT SET
95.24 oz
(2.7 kg)
4.33 in
(110 mm)
2.76 in
(70 mm)
3.15 in
(80 mm)
CHS2U RACK MOUNT KIT
17.6 oz
(0.5 kg)
0.91 in
(23 mm)
9.65 in
(245 mm)
3.35 in
(85 mm)
CHS1U/2U WALL MOUNT KIT
35.27 oz
(1 kg)
1.18 in
(30 mm)
13.8 in
(350 mm)
1.77 in
(45 mm)
CHS LARGE BATT BOX
458.6 oz
(13 kg)
5.24 in
(133 mm)
16.93 in
(430 mm)
14.3 in
(363 mm)
CHS2U JOINT BRACKET KIT
7.06 oz
(0.2 kg)
0.19 in
(3 mm)
5.91 in
(150 mm)
1.7 in
(43 mm)
CHS2U BATT MTG KIT 6 Slot
106 oz
(3.0 kg)
2.95 in
(75 mm)
4.45 in
(113 mm)
4.13 in
(105 mm)
Digital Multiline Terminal
DTL-2E-1 (BK) TEL
35.27 oz
(1.0 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
8.86 in
(225 mm)
DTL-6DE-1 (BK) TEL
38.8 oz
(1.1 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
8.86 in
(225 mm)
DTL-8LD-1 (BK) TEL
DTL-8LD-1 (WH) TEL
45.6 oz
(1.3 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
10.39 in
(264 mm)
DTL-12BT-1 (BK) TEL
45.6 oz
(1.3 kg)
4.29 in
(109 mm)
7.6 in
(183 mm)
10.16 in
(258 mm)
DTL-12PA-1 (BK) TEL
45.6 oz
(1.3 kg)
4.41 in
(112 mm)
7.6 in
(183 mm)
10.16 in
(258 mm)
DTL-12D-1 (BK) TEL
DTL-12D-1 (WH) TEL
42.33 oz
(1.2 kg)
4.39 in
(111.7 mm)
7.05 in
(179 mm)
10.16 in
(258 mm)
DTL-24D-1 (BK) TEL
DTL-24D-1 (WH) TEL
42.33 oz
(1.2 kg)
4.39 in
(111.7 mm)
7.05 in
(179 mm)
10.16 in
(258 mm)
DTL-32D-1 (BK) TEL
DTL-32D-1 (WH) TEL
45.6 oz
(1.3 kg
4.39 in
(111.7 mm)
8.1 in
(205.8 mm)
10.16 in
(258 mm)
IP Multiline Terminal
ITL-2E-1 (BK) TEL
35.27 oz
(1.0 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
8.86 in
(225 mm)
ITL-6DE-1 (BK) TEL
38.8 oz
(1.1 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
8.86 in
(225 mm)
ITL-8LD-1 (BK) TEL
ITL-8LD-1 (WH) TEL
45.6 oz
(1.3 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
10.39 in
(264 mm)
Table 2-17 SV8100 Weights and Dimensions (Continued)
Unit
Shipping
Weight 1
Height
Width
Depth
2 - 30
SV8100 System Specifications
ITL-12BT-1 (BK) TEL
45.6 oz
(1.3 kg)
4.29 in
(109 mm)
7.59 in
(193 mm)
10.16 in
(258 mm)
ITL-12D-1 (BK) TEL
ITL-12D-1 (WH) TEL
42.33 oz
(1.2 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
10.16 in
(258 mm)
ITL-12PA-1 (BK) TEL
45.6 oz
(1.3 kg)
4.41 in
(112 mm)
7.59 in
(193 mm)
10.16 in
(258 mm)
ITL-24D-1 (BK) TEL
ITL-24D-1 (WH) TEL
42.33 oz
(1.2 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
10.16 in
(258 mm)
ITL-32D-1 (BK) TEL
ITL-32D-1 (WH) TEL
45.6 oz
(1.3 kg)
4.41 in
(112 mm)
8.1 in
(205.8 mm)
10.16 in
(258 mm)
ITL-320C-1 (BK) TEL
56.44 oz
(1.6 kg)
4.41 in
(112 mm)
8.94 in
(227 mm)
9.84 in
(250 mm)
Optional
8LK-L (BK) UNIT
8LK-L (WH) UNIT
7.05 oz
(0.2 kg)
1.77 in
(45 mm)
1.15 in
(29.3 mm)
8.82 in
(224 mm)
ADA-L UNIT
2.82 oz
(0.08 kg)
.98 in
(25 mm)
2.56 in
(65 mm)
3.23 in
(82 mm)
APR-L UNIT
5.29 oz
(0.15 kg)
0.98 in
(25 mm)
2.56 in
(65 mm)
3.23 in
(82 mm)
BCH-L (BK) UNIT
5.29 ox
(0.15 kg)
4.41 in
(112 MM)
2.52 in
(64 mm)
8.8 in
(233 mm)
BHA-L Unit
5.29 ox
(0.15 kg)
0.98 in
(25 mm)
2.56 in
(65 mm)
2.84 in
(72 mm)
IPLA-R UNIT
2.82 oz
(0.08 kg)
0.98 in
(25 mm)
2.24 in
(57 mm)
3.94 in
(100 mm)
PGD(2)-U10 ADP
12.4 oz
(0.35 kg)
1.58 in
(40 mm)
6.81 in
(173 mm)
4.13 in
(105 mm)
DCL-60-1 (BK) CONSOLE
DCL-60-1 (WH) CONSOLE
21.16 oz
(.6 kg)
3.23 in
(82 mm)
5.39 in
(137 mm)
8.82 in
(224 mm)
PSA-L (BK) UNIT
PSA-L (WH) UNIT
10.58 oz
(0.3 kg)
3.15 in
(80 mm)
2.91 in
(74 mm)
8.8 in
(223 mm)
WM-L UNIT
1.58 oz
(0.045 kg)
0.996 in
(25.3 mm)
3.996 in
(101.5 mm)
4.92 in
(125 mm)
1 Shipping weight includes the shipping carton.
Table 2-17 SV8100 Weights and Dimensions (Continued)
Unit
Shipping
Weight 1
Height
Width
Depth
System Hardware Manual
3 - 1
Chapter
3
Installing the SV8100 Chassis
SECTION 1
GENERAL INFORMATION
This chapter contains information to help the technician install the chassis
for the SV8100 system. The technician should be familiar with this section
before installing any equipment.
SECTION 2
INSTALLING THE CHASSIS
The CHS2U-EU chassis has six universal blade slots for legacy line/trunk
blade (Single Line Telephone Interface, Digital Multiline Terminal Interface,
Central Office Trunk, ISDN PRI Interface, etc.), In-skin Application Blades
(In-skin UMS, In-Skin Router, etc.). It also houses the BUS Interface
Blade, Power Supply Unit (PSU) and Cooling FAN.
When the CD-CP00 blade is installed in the first 19” chassis, it is referred
to as the controlling chassis. Additional chassis, referred to as expansion
chassis, can be installed to increase the capacity of the system to meet the
customer’s business needs. Each chassis (Expansion or Controlling), is
powered by a MPS7101 power supply.
The chassis can be wall mounted, floor mounted, stand mounted or rack
mounted. The first part of the this chapter describes the differing types of
mounting options and the rest of this section describes how to install the
chassis.
3 - 2
Installing the SV8100 Chassis
2.1
Wall Mounting the 19” Chassis
When wall mounting the chassis, ensure the wall can support the weight of the
chassis (55 lbs per system chassis ---- including blades, cords, power supply,
etc.). The chassis is secured to the wall with a wall mount bracket. Ensure
that enough space is available to allow the installation of additional expansion
chassis.
Figure 3-1 CHS2U Chassis (Front View)
Figure 3-2 CHS2U Chassis (Rear View)
Universal Slot for Legacy Line/Trunk blades and
Application blades (six slots). When using as
controlling chassis, the CD-CP00 is mounted in
Slot 1 (shown).
Slot for PZ-BS10/PZ-BS11 blade
– Connection with CHS2U chassis
Power Supply Unit (PSU)
Fan Unit
(inside of cover)
Internal Battery Mount
Battery Connector
(inside of cover)
AC Connector
Frame Ground
(FG) Terminal
System Hardware Manual
3 - 3
2.1.1
CHS2U Chassis Wall Mount Installation
1.
Use the template shown in Figure 3-3 Wall Mount Spacing
Guide (19” Chassis) on page 3-3 for required spacing before
drilling.
2.
Mark and drill the six holes required for a wall installation.
3.
Align screw holes in wall mount brackets with drilled holes.
Figure 3-3 Wall Mount Spacing Guide (19” Chassis)
Upper Surface of Wall Mount Bracket
3 - 4
Installing the SV8100 Chassis
4.
Using six screws, secure the two wall mount brackets to the
wall. Refer to Figure 3-4 Install Wall Mount Brackets with
Screws for screw location.
5.
Using four screws, secure the metal fittings on the Left and
Right sides of the 19” chassis. Refer to Figure 3-5 Install Wall
Mount Brackets with Screws on page 3-5 for screw location.
Figure 3-4 Install Wall Mount Brackets with Screws
System Hardware Manual
3 - 5
Figure 3-5 Install Wall Mount Brackets with Screws
3 - 6
Installing the SV8100 Chassis
6.
Align the metal fitting with the upper wall mount bracket. The
lower metal fitting will rest against the lower wall mount bracket.
Secure the metal fitting and upper wall mount bracket with a
single screw (see Figure 3-6 Secure Metal Fitting to Upper Wall
Mount Bracket with a Screw).
7.
Using two screws, secure the metal fitting to the lower wall
mount bracket. Refer to Figure 3-7 Secure Metal Fitting to
Lower Wall Mount Bracket with Screws on page 3-7 for screw
location.
Figure 3-6
Secure Metal Fitting to Upper Wall Mount Bracket
with a Screw
System Hardware Manual
3 - 7
8.
Attach the supplied cable support bracket to either end of the
lower wall mount bracket with a single screw (refer to Figure
3-8 Attach Cable Support Bracket with Screw on page 3-8).
Figure 3-7
Secure Metal Fitting to Lower Wall Mount
Bracket with Screws
3 - 8
Installing the SV8100 Chassis
9.
The cable support bracket can be installed any of the four
corners of the 19” chassis (refer to Figure 3-9 Attach Cable
Support Bracket with Screw on page 3-9).
Figure 3-8 Attach Cable Support Bracket with Screw
System Hardware Manual
3 - 9
10.
Connect the ground wire to all chassis. Refer to 2.5.5 Install
19” Chassis Grounding on page 3-34 for complete details on
grounding the system.
11.
Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue
installation of the chassis or, Chapter 5 paragraph 2.2 Installing
an Extension or Trunk Blade on page 4-4 for installation of
blades.
Figure 3-9 Attach Cable Support Bracket with Screw
3 - 10
Installing the SV8100 Chassis
2.2
Floor Mounting the 19” Chassis
The CHS2U controlling and expansion chassis can be mounted on the floor
using the CHS BASE UNIT and the CHS2U JOINT BRACKET KIT.
2.2.1
CHS2U Chassis Installation
1.
Use the template shown in Figure 3-10 Floor Mount Spacing
Guide for required spacing before drilling holes for 0.39”
(10mm) anchor bolts (locally procured).
2.
Mark and drill the four holes required for installing the CHS
BASE UNIT.
3.
Using anchor bolts, secure the CHS BASE UNIT to the floor.
Refer to Figure 3-11 Secure CHS BASE UNIT with Anchor
Bolts on page 3-11 for screw location.
Figure 3-10 Floor Mount Spacing Guide
System Hardware Manual
3 - 11
.
4.
Install the five rubber feet to the bottom of the chassis.
5.
Position the chassis on top of the CHS BASE UNIT.
6.
Secure the chassis to the CHS BASE UNIT using eight screws
supplied with the CHS2U JOINT BRACKET KIT.
Figure 3-11 Secure CHS BASE UNIT with Anchor Bolts
Figure 3-12 Install Rubber Feet
3 - 12
Installing the SV8100 Chassis
7.
Connect the ground wire to all chassis. Refer to 2.5.5 Install
19” Chassis Grounding on page 3-34 for complete details on
grounding the system.
8.
Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue
installation of the chassis or, Chapter 5 paragraph 2.2
Installing an Extension or Trunk Blade on page 4-4 for
installation of blades.
2.2.2
Multiple CHS2U Chassis Installation
Expansion chassis can be secured to the CHS BASE UNIT and will
require an additional CHS2U JOINT BRACKET KIT per chassis.
Figure 3-13 Install CHS2U JOINT BRACKET KIT
System Hardware Manual
3 - 13
1.
Install the five rubber feet to the bottom of each chassis.
2.
Using supplied screws in the CHS2U JOINT BRACKET KIT,
attach metal brackets to both ends of the 19” chassis and the
CHS BASE UNIT. Refer to Figure 3-15 Install Metal Brackets
with Screws.
Figure 3-14 Install Rubber Feet
Figure 3-15 Install Metal Brackets with Screws
Metal
Brackets
3 - 14
Installing the SV8100 Chassis
3.
Connect the ground wire to all chassis. Refer to 2.5.5 Install
19” Chassis Grounding on page 3-34 for complete details on
grounding the system.
4.
Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue
installation of the chassis or, Chapter 5 paragraph 2.2
Installing an Extension or Trunk Blade on page 4-4 for
installation of blades.
2.3
Stand Mounting the 19” Chassis
A single or multiple chassis can be stand mounted. Controlling and Expansion
chassis can be stand mounted using the CHS2U STAND KIT(K) and CHS2U
STAND KIT (EXT).
2.3.1
CHS2U Chassis Installation
1.
Using the supplied screws, assemble the CHS2U STAND
KIT(K) and CHS2U STAND KIT (EXT) (refer to Figure 3-16
Assemble Stand Mount with Screws).
2.
Secure the CHS2U chassis to the assembled CHS2U STAND
KIT, see Figure 3-17 Secure CHS2U Chassis to CHS2U
STAND KIT with Screws on page 3-15.
Figure 3-16 Assemble Stand Mount with Screws
Expansion
Plate
System Hardware Manual
3 - 15
3.
Using supplied screws, secure the CHS2U STAND KIT to the
floor (refer to Figure 3-18 Secure Stand Mount to Floor with
Screws on page 3-16).
Figure 3-17 Secure CHS2U Chassis to CHS2U STAND KIT with Screws
Expansion
Plate
3 - 16
Installing the SV8100 Chassis
4.
Connect the ground wire to all chassis. Refer to 2.5.5 Install
19” Chassis Grounding on page 3-34 for complete details on
grounding the system.
5.
Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue
installation of the chassis or, Chapter 5 paragraph 2.2 Installing
an Extension or Trunk Blade on page 4-4 for installation of
blades.
Figure 3-18 Secure Stand Mount to Floor with Screws
System Hardware Manual
3 - 17
2.3.2
Multiple CHS2U Chassis Installation
Expansion chassis (maximum of three) can be added to the CHS2U
STAND KIT and will require an additional CHS2U STAND KIT (EXT)
per chassis.
1.
Install the five rubber feet to the bottom of each chassis.
2.
Each additional chassis will require CHS2U STAND KIT (EXT)
to be installed (refer to Figure 3-20 Install Additional CHS2U
STAND KIT (EXT) on page 3-18).
Figure 3-19 Attach Rubber Feet to CHS2U Chassis
3 - 18
Installing the SV8100 Chassis
3.
Metal brackets from the CHS2U JOINT BRACKET KITs will be
required to secure the top end of the chassis with screws. See
Figure 3-21 Install Additional CHS2U STAND KIT (EXT) on
page 3-19.
Figure 3-20 Install Additional CHS2U STAND KIT (EXT)
Expansion
Plates
System Hardware Manual
3 - 19
4.
Using supplied screws, secure the CHS2U STAND KIT to the
floor (refer to Figure 3-21 Install Additional CHS2U STAND KIT
(EXT) on page 3-19).
5.
Connect the ground wire to all chassis. Refer to 2.5.5 Install
19” Chassis Grounding on page 3-34 for complete details on
grounding the system.
6.
Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue
installation of the chassis or, Chapter 5 paragraph 2.2
Installing an Extension or Trunk Blade on page 4-4 for
installation of blades.
Figure 3-21 Install Additional CHS2U STAND KIT (EXT)
Metal
Brackets
3 - 20
Installing the SV8100 Chassis
2.4
Rack Mounting the 19” Chassis
A single or multiple chassis can be rack mounted. Controlling and Expansion
chassis can be racked mounted by stacking them horizontally.
1.
The 19” chassis requires two rack mount brackets per chassis for
mounting. Refer to Figure 3-22 CHS2U Rack Mount Brackets.
2.
Line up the Rack Mount Bracket(s) with the pre-drilled holes on each
side of the 19” chassis.
3.
Secure the brackets to the chassis using the supplied screws. Refer to
Figure 3-23 Rack Mount Bracket Installed 19” CHS2U on page 3-21 for
the 19” chassis.
Figure 3-22 CHS2U Rack Mount Brackets
System Hardware Manual
3 - 21
Repeat for additional chassis mounting.
4.
Carefully slide the chassis into desired location within the rack. Make
sure the hooks on the mounting bracket are inserted into the back of the
chassis, securing it in place. Note that the cabling is run through the front
of the rack for ease of access.
5.
Secure the brackets to the rack using the screws supplied.
Repeat for additional chassis mounting.
Figure 3-23 Rack Mount Bracket Installed 19” CHS2U
Figure 3-24 Rack Mount 19” CHS2U
Each CHS2U chassis will require approximately
3.5” of height within the rack.
Single CHS2U Rack Mount
Single CHS2U Rack Mount
with Three Expansion Chassis
3 - 22
Installing the SV8100 Chassis
6.
Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis
Grounding on page 3-34 for complete details on grounding the system.
7.
Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue
installation of the chassis or, Chapter 5 paragraph 2.2 Installing an
Extension or Trunk Blade on page 4-4 for installation of blades.
2.5
Installing the 19” Chassis
There are two types of chassis; the controlling (with the CD-CP00 installed)
and the expansion (that does not have the CCPU blade installed). As
discussed in other chapters, multiple chassis can be linked together to expand
the port size of the system.
2.5.1
Unpacking the Equipment
Inspect the equipment for any physical damage. If you are not sure
about the function of a component, review the associated information
within this manual. Contact your authorized NEC Sales
Representative if you have additional questions. Note that the
chassis does not initially contain any blades.
Make sure you have appropriate tools for the job, including: a test
set, a punch down tool, and a digital voltmeter.
Ensure that you have a building plan showing common equipment,
extensions, the Telco demarcation and earth ground location before
you start installation. Be sure to properly plan your installation site
and that you are familiar with the installation safety precautions. If
you have not done that, please do so now.
2.5.2
Before Installation
Before installing the chassis check the following:
�
Ensure that the MPS7101(Power Supply Unit) is OFF and that
that the power cord is disconnected from the AC outlet.
�
When installing the blades, do not touch the soldered surfaces
as this may cause damage.
System Hardware Manual
3 - 23
2.5.3
Installing the 19” Controlling Chassis
1.
Ensure the chassis is powered down.
2.
Align the CD-CP00 blade with the Slot 1 guides of the
Controlling Chassis.
3.
Slide the CD-CP00 blade into the chassis until resistance (back
plane) is felt.
Figure 3-25 19” Controlling Chassis – Guides Slot 1
Figure 3-26 Installing the CD-CP00 Blade
Do not remove or install this blade with the
power on.
3 - 24
Installing the SV8100 Chassis
4.
Gently push until the blade seats. Tighten the two retaining
screws on front of the blade.
2.5.4
Installing Expansion Blades in the 19” Chassis (Optional)
When adding additional chassis to the system to expand the
capacity, a PZ-BS10 must be installed in the Controlling Chassis and
a PZ-BS11 must be installed in all Expansion Chassis. This
connection is required with any multiple-chassis setup.
The PZ-BS10 connects the Controlling Chassis to the Expansion
Chassis by connecting to a PZ-BS11, which is installed on each
Expansion Chassis. These Expansion Interface Units allow the CPU
to transmit/receive data as required to the additional chassis.
The PZ-BS10 is installed in the EXIFU slot of the Controlling Chassis
which is equipped with a CPU card. The PZ-BS11 is installed in the
expansion slot of the Expansion Chassis, which does not have a
CPU.
The EXIFU cable connects the Controlling Chassis and its EXIFU-B1
interface to the second, third, and fourth EXIFU-E1 interface.
Use only the CAT 5 cables provided by NEC to make the
connections between the Controlling and Expansion Chassis.
The PZ-BS10 provides:
�
Communication Processor Interface for data handling through
Communication Channel (24 slots maximum)
�
32 Channels for Telephony Resource (e.g., DTMF Tone
Receiver, Call Progress Tone Detector, MFC Tone Receiver,
Caller ID Receiver, Caller ID Signal Sender)
�
DSP Resource Management
Figure 3-27 CD-CP00 Blade Installed
System Hardware Manual
3 - 25
2.5.4.1
Connector Pin-Out on the PZ-BS10/PZ-BS11
2.5.4.2
Install the PZ-BS10 Expansion Base Blade in the CHS2U
Controlling Chassis
1.
Ensure the chassis is powered down.
2.
Locate the door positioned on the left end
(expansion bay) of the Controlling Chassis.
Table 3-1 PZ-BS10/PZ-BS11 Connector Pin-Out
RJ-61 Cable Connector
PZ-BS10 – CN2, CN3, CN 4
PZ-BS11 – CN3
Pin No.
Connection
1
HW_UP (+)
2
HW_UP (-)
3
HW_DWN (+)
4
FS (+)
5
FS (-)
6
HW_DWN (-)
7
CK8M (+)
8
CK8M (-)
Figure 3-28 PZ-BS10 Expansion Bay in Controlling Chassis
Do not remove or install this blade with
the power on.
Expansion Bay
3 - 26
Installing the SV8100 Chassis
3.
From the left side of the chassis, pull cover outward
to expose the expansion bay.
4.
Pull the cover toward you to remove.
.
Cover must be removed prior to installation of PZ-BS10
blade.
5.
Align the PZ-BS10 blade with the guides located in
the expansion bay.
Figure 3-29 Open Base Chassis Cover
Figure 3-30 PZ-BS10 Blade Guides
System Hardware Manual
3 - 27
6.
Slide the PZ-BS10 blade into the chassis until
resistance (back plane) is felt.
7.
Gently push until the blade seats and install the
supplied retaining screw.
Figure 3-31 PZ-BS10 Components
Figure 3-32 Installing PZ-BS10 Blade in Expansion Bay
3 - 28
Installing the SV8100 Chassis
8.
Align the door tabs with hinges and reattach the
cover.
9.
Close the PZ-BS10 cover.
2.5.4.3
Install the PZ-BS11 Expansion Blade in the CHS2U
Expansion Chassis
.
For the Expansion Chassis to function, the PZ-BS10 blade must
be installed in Controlling Chassis.
1.
Ensure the chassis is powered down.
Figure 3-33 PZ-BS10 Blade Installed
Figure 3-34 PZ-BS10 Installed (Cover Closed)
Do not remove or install this blade with
the power on.
System Hardware Manual
3 - 29
2.
Locate the door positioned on the left end
(expansion bay) of the Expansion Chassis.
3.
From the left side of the chassis, pull cover outward
to expose the expansion bay.
Figure 3-35
PZ-BS11 Expansion Bay in Expansion
Chassis
Figure 3-36 Open Expansion Chassis Cover
Expansion Bay
3 - 30
Installing the SV8100 Chassis
4.
Pull the cover toward you to remove.
.
Cover must be removed to install PZ-BS11 blade.
5.
Align the PZ-BS11 blade with the guides located
within the expansion bay.
6.
Slide the PZ-BS11 blade into the chassis until
resistance (back plane) is felt.
7.
Gently push until the blade seats and install the
supplied retaining screw.
Figure 3-37 PZ-BS11 Blade Guides
Figure 3-38
Installing PZ-BS11 Blade in
Expansion Chassis
System Hardware Manual
3 - 31
8.
Align the door tabs with hinges and reattach the
cover.
9.
Close the PZ-BS11 blade cover.
Figure 3-39 PZ-BS11 Blade Installed
Figure 3-40 PZ-BS11 Installed (Cover Closed)
3 - 32
Installing the SV8100 Chassis
2.5.4.4
Connect the Controlling and Expansion Chassis
.
Installment of the PZ-BS10 blade and PZ-BS11 blade(s) must be
completed prior to installation of the provided (Cat 5) expansion
cabling.
1.
Ensure Controlling and Expansion chassis are
powered down.
2.
Using the NEC provided CAT5 straight-through
cable(s), attach one end to each Expansion Chassis
CN2 connector on the PZ-BS11 blade (see Figure
3-42 System Expansion Cabling on page 3-33.
Attach the opposite end to the CN2, CN3 or CN4
connector on the PZ-BS10 of the Controlling
Chassis.
Figure 3-41 19” Expansion Chassis Interface Units
Expansion Chassis Interface Unit
for the Controlling Chassis
PZ-BS10
Expansion Chassis Interface Unit
for the Expansion Chassis
PZ-BS11
System Hardware Manual
3 - 33
3.
Repeat for additional Expansion Chassis.
Figure 3-42 System Expansion Cabling
Install in Controlling
Chassis
Install in Expansion
Chassis
Install in Expansion
Chassis
Install in Expansion
Chassis
3 - 34
Installing the SV8100 Chassis
2.5.5
Install 19” Chassis Grounding
From the factory, the SG, ETH and PBXG grounds are located inside
the chassis and are connected to the FG ground (frame ground) on
the back of the chassis.
Each chassis (CHS2U) in the system must be grounded separately
using the procedure listed below.
1.
Ensure each Chassis is powered down and unplugged.
2.
Ground each chassis by connecting a 14 AWG wire from the
FG lug on the back side of the chassis to an electrical service
ground (such as a cold water pipe).
2.5.6
Install 19” Grounding on Multiple Chassis (Optional)
From the factory, the SG, ETH and PBXG grounds are located inside
the chassis and are connected to the FG ground (frame ground) on
the back of the chassis.
Each chassis (CHS2U) in the system must be grounded separately
using the procedure listed below.
1.
Ensure all Controlling and Expansion Chassis are powered
down and unplugged.
2.
Ground each chassis by connecting a 14 AWG wire from the
FG lug on the back side of the chassis to an electrical service
ground (such as a cold water pipe).
Figure 3-43 Chassis Grounding Lug
FG Lug
CHS2U
System Hardware Manual
3 - 35
2.5.7
Install AC Power Cords
1.
Locate the supplied AC power cord and attach to the AC Inlet
located on the back of the Controlling Chassis.
Figure 3-44 19” Chassis Grounding Lug (Multiple-Chassis)
Figure 3-45 Install the AC Power Cord
FG Lugs
Electrical
Service
Ground
AC Inlet
CHS2U
3 - 36
Installing the SV8100 Chassis
2.5.8
Install AC Power Cords on Multiple-Chassis (Optional)
1.
Locate the supplied AC power cords and attach to the AC Inlets
located on the back of the Controlling and Expansion Chassis.
2.5.9
Install Additional Blades
Refer to Chapter 5, 2.1 Installation and Safety Precautions on page
4-3.
2.5.10
Apply Power to the 19” Chassis
Refer to Chapter 5, 2.6 Powering Up the SV8100 on page 4-8.
Figure 3-46 Install 19” AC Power Cords (Multiple-Chassis)
AC Power
Cords to
AC Inlets
System Hardware Manual
3 - 37
SECTION 3
BATTERY CONNECTION
There are two types of battery connection to provide battery life in the event of a
power failure, the internal battery and an external battery with CHS LARGE BATT
BOX.
3.1
Installing the Internal Batteries
An internal battery source using two batteries can be installed using the
CHS2U BATT MTG KIT (mounting kit) and CHS2U BATT CABLE INT (internal
cabling).
CHS2U BATT MTG KIT (Backup time = 10 Minutes/24 Terminals)
1.
Ensure the chassis is powered down.
2.
Disconnect AC power and grounding cable from rear of chassis.
3.
Remove screws from battery access panel on rear of chassis. Refer to
Figure 3-47 Removing Battery Access Panel.
Figure 3-47 Removing Battery Access Panel
Ensure the CHS2U chassis is powered OFF.
3 - 38
Installing the SV8100 Chassis
4.
Remove access panel containing the fan. Refer to Figure 3-48 Removing
Access Panel and Figure 3-49 Access Panel Removed.
Figure 3-48 Removing Access Panel
Figure 3-49 Access Panel Removed
System Hardware Manual
3 - 39
5.
Using tie wraps, secure CHS2U BATT CABLE INT in cable guide bracket
(refer to Figure 3-50 Installing Cable Guide).
6.
With supplied screw, install cable guide in chassis (refer to Figure 3-51
Installing Cable Guide).
Figure 3-50 Installing Cable Guide
Figure 3-51 Installing Cable Guide
3 - 40
Installing the SV8100 Chassis
7.
Install two 2.3 AH-12V batteries (locally procured) into the CHS2U BATT
MTG KIT (refer to Figure 3-52 Installing Two Batteries).
.
The first battery must be installed on the left side, then slid to the right due to an
installation tab on the mounting kit.
8.
Using the supplied screws, secure the brackets to the CHS2U BATT
MTG KIT (refer to Figure 3-52 Installing Two Batteries on page 3-40).