NEC SV-8100 System Hardware Manual

Text of the manual

System Hardware Manual

i ___________________________________________________________________________________ ___________________________________________________________________________________ TABLE OF CONTENTS Regulatory Chapter 1 Introduction to SV8100 Section 1 General Information ....................................................................1-1 Section 2 Equipment List ............................................................................1-4 Chapter 2 SV8100 System Specifications Section 1 General Information .....................................................................2-1 Section 2 System Block Diagram ................................................................2-1 Section 3 Maximum System Capacities ....................................................2-5 3.1 System Configuration – SV8100 ................................................. 2-6 Section 4 Power-Based Calculator Chart .................................................2-13 Section 5 System Requirements and Specifications ..............................2-16 5.1 Cabling ...................................................................................... 2-16 5.2 Power Requirements ................................................................. 2-19 5.2.1 Power Supply Specifications ....................................................2-19 5.2.2 Power Supply Consumption .....................................................2-20 5.3 Environmental Conditions .......................................................... 2-20 5.3.1 Temperature and Humidity ......................................................2-20 5.4 Outside Line Types .................................................................... 2-21 5.5 Transmission, Network, and Control Specifications .................. 2-21

Table of Contents

___________________________________________________________________________________ 5.5.1 Transmission ............................................................................2-21 5.5.2 Network ....................................................................................2-22 5.5.3 Control ......................................................................................2-22 5.5.4 Electra Elite IPK Terminals and Equipment .............................2-23 5.5.5 Series i Terminals ....................................................................2-24 5.6 Dialing Specifications .................................................................2-24 5.6.1 Dial Pulse Address Signaling ...................................................2-24 5.6.2 Dual-Tone Multifrequency (DTMF) Address Signaling .............2-24 5.6.3 External Equipment Connection ...............................................2-25 5.6.4 Music Source for Music on Hold via Chassis ...........................2-25 5.6.5 Music Source for Station Background Music via ACI ...............2-25 5.6.6 External Paging (Audio) ...........................................................2-25 5.6.7 External Tone Ringer/Night Chime Output ...............................2-26 5.6.8 SMDR Output ...........................................................................2-26 5.6.9 PC Connection .........................................................................2-26 5.6.10 Relay Contact ...........................................................................2-26 5.7 Battery Backup ..........................................................................2-26 5.7.1 System Backup (Optional) .......................................................2-26 5.7.2 Memory Backup .......................................................................2-26 5.8 Weights and Dimensions ...........................................................2-27 Chapter 3 Installing the SV8100 Chassis Section 1 General Information .................................................................... 3-1 Section 2 Installing the Chassis ................................................................. 3-1 2.1 Wall Mounting the 19” Chassis ....................................................3-2 2.1.1 CHS2U Chassis Wall Mount Installation ....................................3-3 2.2 Floor Mounting the 19” Chassis .................................................3-10

System Hardware Manual

- iii ___________________________________________________________________________________ ___________________________________________________________________________________ System Hardware Manual iii ___________________________________________________________________________________ 2.2.1 CHS2U Chassis Installation .....................................................3-10 2.2.2 Multiple CHS2U Chassis Installation .......................................3-12 2.3 Stand Mounting the 19” Chassis ............................................... 3-14 2.3.1 CHS2U Chassis Installation .....................................................3-14 2.3.2 Multiple CHS2U Chassis Installation .......................................3-17 2.4 Rack Mounting the 19” Chassis ................................................. 3-20 2.5 Installing the 19” Chassis .......................................................... 3-22 2.5.1 Unpacking the Equipment ........................................................3-22 2.5.2 Before Installation ....................................................................3-22 2.5.3 Installing the 19” Controlling Chassis .......................................3-23 2.5.4 Installing Expansion Blades in the 19” Chassis (Optional) ......3-24 2.5.4.1 Connector Pin-Out on the PZ-BS10/PZ-BS11 ....................3-25 2.5.4.2 Install the PZ-BS10 Expansion Base Blade in the CHS2U Con- trolling Chassis 3-25 2.5.4.3 Install the PZ-BS11 Expansion Blade in the CHS2U Expansion Chassis 3-28 2.5.4.4 Connect the Controlling and Expansion Chassis ...............3-32 2.5.5 Install 19” Chassis Grounding ..................................................3-34 2.5.6 Install 19” Grounding on Multiple Chassis (Optional) ...............3-34 2.5.7 Install AC Power Cords ............................................................3-35 2.5.8 Install AC Power Cords on Multiple-Chassis (Optional) ...........3-36 2.5.9 Install Additional Blades ...........................................................3-36 2.5.10 Apply Power to the 19” Chassis ...............................................3-36 Section 3 Battery Connection ...................................................................3-37 3.1 Installing the Internal Batteries ..................................................3-37 3.2 Installing the External Batteries ................................................. 3-43 3.2.1 Floor Mounting the CHS LARGE BATT BOX ..........................3-43 3.2.2 Battery Installation ...................................................................3-45 3.2.3 CHS LARGE BATT BOX to CHS2U Connection .....................3-49

Table of Contents

___________________________________________________________________________________ Section 4 Remove and Install Cooling Fan .............................................. 3-53 4.1 CHS2U Chassis .........................................................................3-53 4.1.1 Remove Cooling Fan ............................................................3-53 4.1.2 Install Cooling Fan ...................................................................3-55 Chapter 4 Installing the SV8100 Blades Section 1 General Information .................................................................... 4-1 1.1 Slot Locations ..............................................................................4-1 Section 2 Installation .................................................................................. 4-3 2.1 Installation and Safety Precautions .............................................4-3 2.2 Installing an Extension or Trunk Blade ........................................4-4 2.2.1 Installing the Blades ...................................................................4-4 2.2.2 Order of Installing Extension Blades ..........................................4-4 2.2.3 Order of Installing Trunk Blades .................................................4-6 2.2.3.1 Installing CD-4COTA, CD-4DIOPB, CD-4ODTA or CD-2BRIA blades 4-6 2.2.3.2 Installing CD-PRTA (T1/PRI) Blades ................................... 4-7 2.3 Remove an Extension or Trunk Blade .........................................4-7 2.4 Uninstalling a Blade Slot Through Software ................................4-7 2.5 Blade Capacities ..........................................................................4-8 2.6 Powering Up the SV8100 ............................................................4-8 2.6.1 Performing a Cold Start ..............................................................4-8 2.6.2 Performing a Hot Start ...............................................................4-9 2.6.3 Resetting the System .................................................................4-9 2.6.3.1 Initial Programming .............................................................. 4-9 2.6.3.2 Port Defaults ...................................................................... 4-10 2.6.3.3 Setting Up Extension Circuit Types ................................... 4-10 2.6.3.4 Saving Your Configuration ................................................. 4-11

System Hardware Manual

- v ___________________________________________________________________________________ ___________________________________________________________________________________ System Hardware Manual v ___________________________________________________________________________________ 2.6.3.5 Backing Up/Restoring a Database .....................................4-11 2.6.4 Performing a Software Upgrade ..............................................4-12 Section 3 Common Control Blades ..........................................................4-14 3.1 CD-CP00 (SV8100 Central Processing Unit) ............................ 4-14 3.1.1 Description ...............................................................................4-15 3.1.2 Installation ................................................................................4-18 3.1.3 Switch Settings ........................................................................4-20 3.1.4 LED Indications ........................................................................4-20 3.1.5 Connectors ...............................................................................4-22 3.2 PZ-ME50 (Memory Expansion Daughter Board) ....................... 4-25 3.2.1 Description ...............................................................................4-25 3.2.2 Installation ................................................................................4-27 3.3 PZ-VM21 (Voice Mail Daughter Board) .................................... 4-28 3.3.1 Description ...............................................................................4-28 3.3.2 Installation ................................................................................4-29 3.3.3 Switch Settings ........................................................................4-31 3.4 PZ-32IPLA/PZ-64IPLA/PZ-128IPLA (Voice over IP Daughter Boards) 4-31 3.4.1 Description ...............................................................................4-32 3.4.2 Installation ................................................................................4-33 3.4.3 Switch Settings ........................................................................4-33 3.4.4 LED Indications ........................................................................4-34 3.4.5 Connectors ...............................................................................4-35 Section 4 Station Blades ............................................................................4-37 4.1 CD-8DLCA/CD-16DLCA (Digital Station Interface) .................. 4-37 4.1.1 Description ...............................................................................4-38 4.1.2 Installation ................................................................................4-39

Table of Contents

___________________________________________________________________________________ 4.1.3 LED Indications ........................................................................4-39 4.1.4 Connectors ...............................................................................4-40 4.2 PZ-8DLCB (Digital Station Daughter Board) .............................4-42 4.2.1 Description ...............................................................................4-42 4.2.2 Installation ................................................................................4-43 4.2.3 PZ-8DLCB Daughter Board Cable Connection ........................4-43 4.3 CD-4LCA/ CD-8LCA (4-Port/8-Port Single Line Interface) ........4-45 4.3.1 Description ...............................................................................4-46 4.3.2 Installation ................................................................................4-47 4.3.3 LED Indications ........................................................................4-48 4.3.4 Connectors ...............................................................................4-49 4.4 PZ-4LCA/PZ-8LCE (4-Port/8-Port SLI Daughter Boards) ..........4-50 4.4.1 Description ...............................................................................4-52 4.4.2 Installation ................................................................................4-53 4.4.3 Connectors ...............................................................................4-54 4.5 CD-LTA (Dterm/SLT Combination) .............................................4-55 4.5.1 Description ...............................................................................4-55 4.5.2 Installation ................................................................................4-56 4.5.3 LED Indications ........................................................................4-57 4.5.4 Connectors ...............................................................................4-58 Section 5 Trunk Blades ............................................................................. 4-59 5.1 CD-4COTA (4 Loop Start Interface) ..........................................4-59 5.1.1 Description ...............................................................................4-59 5.1.2 Installation ................................................................................4-61 5.1.3 LED Indications ........................................................................4-61 5.1.4 Connectors ...............................................................................4-62 5.2 PZ-4COTE (4 Loop Start Interface Daughter Board) .................4-63

System Hardware Manual

- vii ___________________________________________________________________________________ ___________________________________________________________________________________ System Hardware Manual vii ___________________________________________________________________________________ 5.2.1 Description ...............................................................................4-63 5.2.2 Installation ................................................................................4-65 5.2.3 Connectors ...............................................................................4-65 5.3 CD-2BRIA (2 Basic Rate Interface) ...........................................4-67 5.3.1 Description ...............................................................................4-67 5.3.2 Installation ................................................................................4-68 5.3.3 LED Indications ........................................................................4-69 5.3.4 Connectors ...............................................................................4-70 5.3.5 Termination Switch Settings ....................................................4-70 5.4 PZ-2BRIA (2 Basic Rate Interface Daughter Board) ................. 4-72 5.4.1 Description ...............................................................................4-73 5.4.2 Installation ................................................................................4-73 5.4.3 Connectors ...............................................................................4-74 5.4.4 Termination Switch Settings ....................................................4-75 5.5 CD-4DIOPB (DID/OPX Interface) .............................................. 4-76 5.5.1 Description ...............................................................................4-76 5.5.2 Installation ................................................................................4-77 5.5.3 LED Indications ........................................................................4-77 5.5.4 Connectors ...............................................................................4-78 5.6 CD-PRTA (PRI Interface) .........................................................4-79 5.6.1 Description ...............................................................................4-79 5.6.2 Installation ................................................................................4-80 5.6.3 LED Indications ........................................................................4-82 5.6.4 Connectors ...............................................................................4-84 5.7 CD-4ODTA (4-Port Tie Line Interface Blade) ............................ 4-86 5.7.1 Description ...............................................................................4-86 5.7.2 Installation ................................................................................4-87

Table of Contents

___________________________________________________________________________________ 5.7.3 LED Indications ........................................................................4-88 5.7.4 Connectors ...............................................................................4-88 5.7.5 Connections .............................................................................4-90 Section 6 Optional Blades ......................................................................... 4-92 6.1 CD-PVAA (Conference Bridge) (Future Enhancement) ............4-92 6.1.1 Description ...............................................................................4-92 6.1.2 Installation ................................................................................4-93 6.1.3 Switch Settings .........................................................................4-93 6.1.4 LED Indications ........................................................................4-93 6.1.5 Connectors ...............................................................................4-94 6.2 CD-RTB (4-Port ) (Future Enhancement) ..................................4-95 6.2.1 Description ...............................................................................4-95 6.2.2 Installation ................................................................................4-97 6.2.3 LED Indications ........................................................................4-97 6.3 CD-ETIA (Gigabit PoE Switch) ..................................................4-98 6.3.1 Description ...............................................................................4-98 6.3.2 Installation ................................................................................4-99 6.3.2.1 Stacking Architecture ......................................................... 4-99 6.3.2.2 CD-CP00IP Address Assignment .................................... 4-100 6.3.2.3 Group Formation .............................................................. 4-100 6.3.2.4 Port Number Determination ............................................. 4-100 6.3.2.5 Unmanaged Switch Functions ......................................... 4-101 6.3.3 LED Indications ......................................................................4-101 6.3.4 Connectors .............................................................................4-101 Chapter 5 Installing DT300/DT700 Series (DTL/ITL) Digital and IP Multiline Terminals Section 1 General Description .................................................................... 5-1

System Hardware Manual

- ix ___________________________________________________________________________________ ___________________________________________________________________________________ System Hardware Manual ix ___________________________________________________________________________________ Section 2 DT300 Series Digital Multiline Terminals ..................................5-6 2.1 Digital MultilineTerminals ............................................................. 5-6 2.1.1 DTL-2E-1 (BK) TEL ....................................................................5-6 2.1.2 DTL-6DE-1 (BK) TEL .................................................................5-7 2.1.3 DTL-8LD-1 (BK) TEL/DTL-8LD-1 (WH) TEL ..............................5-7 2.1.4 DTL-12BT-1 (BK) TEL ...............................................................5-8 2.1.5 DTL-12D-1 (BK) TEL/DTL-12D-1 (WH) TEL ..............................5-9 2.1.6 DTL-12PA-1 (BK) TEL .............................................................5-10 2.1.7 DTL-24D-1 (BK) TEL/DTL-24D-1 (WH) TEL ............................5-11 2.1.8 DTL-32D-1 (BK) TEL/DTL-32D-1 (WH) TEL ............................5-12 Section 3 DT700 Series IP Multiline Terminals ........................................5-14 3.1 IP MultilineTerminals ................................................................. 5-14 3.1.1 ITL-2E-1 (BK) TEL ...................................................................5-14 3.1.2 ITL-6DE-1 (BK) TEL .................................................................5-15 3.1.3 ITL-8LD-1 (BK) TEL/ITL-8LD-1 (WH) TEL ...............................5-15 3.1.4 ITL-12D-1 (BK) TEL/ITL-12D-1 (WH) TEL ...............................5-16 3.1.5 ITL-12PA-1 (BK) TEL ...............................................................5-17 3.1.6 ITL-24D-1 (BK) TEL/ITL-24D-1 (WH) TEL ...............................5-18 3.1.7 ITL-32D-1 (BK) TEL/ITL-32D-1 (WH) TEL ...............................5-19 3.1.8 ITL-320C-1 (BK) TEL ...............................................................5-20 Section 4 Install Multiline Terminals .........................................................5-22 4.1 Connecting the DT300 Series Multiline Terminal to the System 5-22 4.2 Applying Power to the DT700 Multiline Terminals ..................... 5-23 4.3 Connecting the IP Multiline Terminal to the Network and PC .... 5-24 4.4 Adjusting the LCD on the Multiline Terminal ............................. 5-25 4.5 Installing Line Key Kit (12LK-L KIT) ...........................................5-26

Table of Contents

___________________________________________________________________________________ 4.5.1 Installing the 12LK-L KIT ..........................................................5-26 4.5.2 Configuring the Digital Telephone for the Correct Number of Line Keys 5-30 4.5.3 Configuring the IP Telephone for the Correct Number of Line Keys 5-30 4.6 Installing the Directory Card on the Multiline Terminal ..............5-32 4.7 Installing a Numbered Keypad on the Multiline Terminal ..........5-33 4.7.1 Installing the Numbered Keypad on a Multiline Terminal ........5-35 4.7.2 Configuring the Digital Telephone for the Numbered Keypad ..5-37 4.7.3 Configuring the IP Telephone for the Numbered Keypad ........5-37 4.8 Adjusting the Height on the Multiline Terminal ..........................5-39 4.9 Removing or Installing the Tilt Legs on the Multiline Terminal ..5-40 4.9.1 Remove Tilt Legs .....................................................................5-40 4.9.2 Install Tilt Legs .........................................................................5-41 4.10 Wall Mounting the Multiline Terminal .........................................5-43 4.10.1 Wall Mounting a Multiline Terminal using the Base Plate ........5-43 4.10.1.1 Adjusting the Hanger Hook ................................................ 5-43 4.10.1.2 Wall Mounting the Multiline Terminal ................................. 5-44 4.10.1.3 Removing the Multiline Terminal from the Wall Mounted Base Plate. 5-45 4.10.1.4 Wall Mounting the Base on a Switch Box .......................... 5-46 Section 5 Multiline Terminals Optional Equipment ................................ 5-47 5.1 DT300/DT700 Series Terminal Options .....................................5-47 5.2 DT300/DT700 Series Optional Terminal Equipment .................5-48 5.2.1 8LK-L (BK) UNIT/8LK-L (WH) UNIT .........................................5-48 5.2.1.1 Installing the 8LK-L UNIT ................................................... 5-48 5.2.2 8LKD (LD)-L (BK) UNIT/8LKD (LD)-L (WH) UNIT ...................5-50 5.2.2.1 Installing the 8LKD (LD)-L UNIT ........................................ 5-51 5.2.3 8LKI (LD)-L (BK) UNIT/8LKI (LD)-L (WH) UNIT .......................5-54

System Hardware Manual

- xi ___________________________________________________________________________________ ___________________________________________________________________________________ System Hardware Manual xi ___________________________________________________________________________________ 5.2.3.1 Installing the 8LKI (LD)-L UNIT ..........................................5-55 5.2.4 DCL-60-1 (BK) CONSOLE/DCL-60-1 (WH) CONSOLE .........5-58 5.2.4.1 Installing the DCL-60-1 CONSOLE ....................................5-59 5.2.5 LCD (BL)-L (BK) UNIT/LCD (BL)-L (WH) UNIT .......................5-63 5.2.6 PANEL( )-L UNIT ....................................................................5-64 5.2.7 WM-L UNIT Attached to Wall ...................................................5-64 5.2.8 Release the WM-L UNIT ..........................................................5-66 5.2.9 WM-L UNIT Attached to Wall Plate ..........................................5-67 5.2.10 Removing the Multiline Terminal from the Wall Mounted Plate. ..... 5-69 Section 6 Optional Handsets .....................................................................5-70 6.1 ITL / DTL PTM Handset ............................................................. 5-70 6.2 ITL / DTL PTT Handset ............................................................. 5-70 6.3 UTR-1-1 USB Handset .............................................................. 5-71 6.3.1 Handset Connection ................................................................5-71 6.3.2 USB Connection ......................................................................5-71 6.3.3 Wall Mounting ..........................................................................5-72 Section 7 Bluetooth Cordless Handset ....................................................5-73 7.1 Bluetooth Cordless Handset (BCH) Interface ............................ 5-73 7.2 Selecting a Location .................................................................. 5-74 7.3 Controls and Indicators .............................................................. 5-75 7.4 Installing the Bluetooth Cordless Handset ................................. 5-77 7.4.1 Installing the Bluetooth Handset Cradle ...................................5-77 7.4.2 Wall Mounting the Bluetooth Cradle ........................................5-83 7.4.3 Remove and Replace Handset Battery ....................................5-86 Section 8 Bluetooth Hub Adapter .............................................................5-87

Table of Contents

___________________________________________________________________________________ 8.1 Bluetooth Hub Adapter (BHA) Features ....................................5-87 8.1.1 Installing the BHA-L UNIT ........................................................5-87 8.1.2 Pairing a Bluetooth Device and Multiline Terminal (Bluetooth In- stalled) 5-89 8.1.2.1 Accessing the Bluetooth Device Setup Screen .................. 5-89 8.1.2.2 Entering a PIN Code .......................................................... 5-89 8.1.2.3 Pairing ................................................................................ 5-89 8.1.2.4 Connecting the Paired Device ........................................... 5-90 8.1.2.5 Unpairing ........................................................................... 5-90 8.1.2.6 Visibility Setting .................................................................. 5-90 8.1.2.7 BT Information ................................................................... 5-91 Section 9 Single Line Telephone .............................................................. 5-92 9.1 Installing the SLT Adapter .........................................................5-92 9.2 Wall-Mounting the SLT Adapter .................................................5-93 Chapter 6 Installing SV8100 Optional Equipment Section 1 General Information .................................................................... 6-1 Section 2 PGD(2)-U10 ADP .......................................................................... 6-1 2.1 Using a PGD(2)-U10 ADP ...........................................................6-1 2.2 LED Indications ............................................................................6-2 2.3 Setting up PGD(2)-U10 ADP Connections ..................................6-2 Section 3 Background Music .................................................................... 6-10 3.1 Installing Background Music ......................................................6-10 Section 4 Door Box .................................................................................... 6-11 4.1 Installing a Door Box ..................................................................6-11 Section 5 External Paging ......................................................................... 6-15

System Hardware Manual

- xiii ___________________________________________________________________________________ ___________________________________________________________________________________ System Hardware Manual xiii ___________________________________________________________________________________ 5.1 External Page ............................................................................ 6-15 5.2 Installing an External Page System ...........................................6-15 Section 6 External Paging and Door Box/Page Relays ...........................6-17 6.1 External Page Relays ................................................................6-17 6.2 Door Box /External Page Relay Contacts .................................. 6-18 6.2.1 Connecting a Contact Relay Device to a Door Box/External Page Relay 6-18 Section 7 External Recording System/External Ringer ..........................6-19 7.1 External Recording System or External Ringer ......................... 6-19 7.2 Installing an External Recording System or External Ringer ..... 6-20 7.3 Programming ............................................................................. 6-21 Section 8 Music Sources ...........................................................................6-24 8.1 Music on Hold ............................................................................ 6-24 8.2 Installing External Music on Hold .............................................. 6-24 Section 9 Night Mode Selection ................................................................6-27 9.1 Night Mode Selector Switch ...................................................... 6-27 9.2 Connecting a Night Mode Selector Switch ................................ 6-27 Section 10 Telephone Labeling ...................................................................6-27 10.1 DESI Printer Sheets .................................................................. 6-27 10.1.1 Removing the Faceplate ..........................................................6-28 10.1.2 Replacing the Faceplate ..........................................................6-28 Section 11 Telephone Adapters ..................................................................6-29 11.1 Using Adapters .......................................................................... 6-29 11.2 In-line Power Adapter (ILPA-R) ................................................. 6-29

Table of Contents

___________________________________________________________________________________ 11.2.1 Conditions ................................................................................6-30 11.2.2 Installation ................................................................................6-31 11.3 ADA-L UNIT ...............................................................................6-33 11.3.1 ADA-L UNIT Switch Settings ....................................................6-34 11.3.2 Installing the ADA-L UNIT ........................................................6-35 11.3.3 ADA-L UNIT Connection ..........................................................6-37 11.3.3.1 ADA-L UNIT Connection for Recording Only ..................... 6-37 11.3.3.2 ADA-L UNIT Connection for Sending Recorded Calls to the Telephone 6-38 11.4 APR-L UNIT ...............................................................................6-38 11.4.1 APR-L UNIT Switch Settings ....................................................6-39 11.4.2 Installing the APR-L UNIT ........................................................6-39 11.5 PSA-L (BK) UNIT / PSA-L (WH) UNIT .......................................6-43 11.5.1 Installing the PSA-L Adapter ....................................................6-44 11.5.2 Using the PSA-L Adapter .........................................................6-50 Section 12 Power Failure Telephones ........................................................ 6-51 12.1 Power Failure .............................................................................6-51 12.2 Connector Pin-Outs on COIU Blade for Power Failure Circuits 6-52 12.3 Installing the Power Failure Telephones ....................................6-52

System Hardware Manual

R-1 BATTERY DISPOSAL The UNIVERGE SV8100 system includes the batteries listed below. When disposing of these batteries, Chassis, and/or Blades, you must comply with applicable regulations regarding proper disposal procedures. The UNIVERGE SV8100 CD-CP00 provides memory backup for approximately three years. The Lithium battery should be replaced every two years. IMPORTANT SAFEGUARDS FOR BATTERY DISPOSAL DO NOT PLACE USED BATTERIES IN YOUR REGULAR WASTE! THE PRODUCT YOU PURCHASED CONTAINS LITHIUM, NICKEL-CADMIUM OR SEALED LEAD BATTERIES. LITHIUM, NICKEL-CADMIUM OR SEALED LEAD BATTERIES MUST BE COLLECTED, RECYCLED, OR DISPOSED OF IN AN ENVIRONMENTALLY SOUND MANNER. The incineration, landfilling or mixing of nickel-cadmium or sealed lead batteries with the municipal solid waste stream is PROHIBITED BY LAW in most areas. Contact your local solid waste management officials for other information regarding the environmentally sound collection, recycling, and disposal of the battery. Table R-1 Battery Types and Quantities for Chassis and Blades Unit Name Type of Battery Quantity CD-CP00 Lithium 1 CHS LARGE BATT SET Sealed Lead 6 Internal Batteries Sealed Lead 2 Bluetooth® Cordless Handset Lithium-ion 1 Regulatory

Nickel-Cadmium (or sealed lead) batteries must be returned to an approved nickel-cadmium (or sealed

lead) battery recycler. This may be where the batteries were originally sold or a local seller of automotive batteries. Contact your local waste management officials for other information regarding the environmentally sound collection, recycling and disposal of the battery contained in this product. The packaging for the UNIVERGE SV8100 system contains the following labels regarding proper disposal. PRODUCT PACKAGE LABELING CONTAINS NICKEL-CADMIUM BATTERY. BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY. MUST NOT BE DISPOSED OF IN MUNICIPAL WASTE. CONTAINS SEALED LEAD BATTERY. BATTERY MUST BE RECYCLED. MUST NOT BE DISPOSED OF IN MUNICIPAL WASTE. Pb Ni-Cd CONTAINS NICKEL-METAL HYDRIDE BATTERY. BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY. MUST NOT BE DISPOSED OF IN MUNICIPAL WASTE. Ni-MH

System Hardware Manual

R-3 EUROPEAN UNION INFORMATION Notice to the user The system described in this manual is intended to be connected to analog and digital networks and supports a wide range of peripheral equipment. The following interfaces are available for connection to public analog and digital telecommunication networks: � TBR3 ISDN basic rate interface � TBR4 ISDN primary rate interface � ES203-021 Analogue interface To take advantage of all features of this system and the connected equipment, the country or network specific features should match the supported features of the system. For an overview of the supported features, refer to the detailed documentation that comes with this system, contact your local NEC Philips representative or the support desk of NEC Philips Unified Solutions. Declaration of conformity Hereby, “NEC Philips Unified Solutions”, declares that the SV8100 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. http://www.nec-philips.com/doc Electromagnetic Compatibility For the SV8100 system the following warning is applicable: Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

PRODUCT DISPOSAL INFORMATION

For Countries in the European Union The symbol depicted here has been affixed to your product in order to inform you that electrical and electronic products should not be disposed of as municipal waste. Electrical and electronic products including the cables, plugs and accessories should be disposed of separately in order to allow proper treatment, recovery and recycling. These products should be taken to a designated facility where the best available treatment, recovery and recycling techniques are available. Separate disposal has significant advantages: valuable materials can be re- used and it prevents the dispersion of unwanted substances into the municipal waste stream. This contributes to the protection of human health and the environment. Please be informed that a fine may be imposed for illegal disposal of electrical and electronic products via the general municipal waste stream. In order to facilitate separate disposal and environmentally sound recycling arrangements have been made for local collection and recycling. In case your electrical and electronic products need to be disposed of please refer to your supplier or the contractual agreements that your company has made upon acquisition of these products. At www.nec-philips.com/weee you can find information about separate disposal and environmentally sound recycling. Battery information Defective or exhausted batteries should never be disposed of as municipal waste. Return old batteries to the battery supplier, a licensed battery dealer or a designated collection facility. Do not incinerate batteries. This product uses Lithium batteries. Do not use any other type. For an overview of the location of batteries used in these systems, the battery replacement or removal instructions, please refer to the UNIVERGE SV8100 System Hardware Manual.

System Hardware Manual

1 - 1 Chapter 1 Introduction to SV8100 SECTION 1 GENERAL INFORMATION The SV8100 is a full-featured IP based communications system providing a rich feature set of existing system, with pure Voice over IP (VoIP) communications, across corporate Local and Wide Area Networks (LAN and WAN). The DT700 series telephones provide a converged infrastructure at the desktop, with a 10Base-T/100Base-TX connection to the LAN and built-in hub for a PC connection to the telephone itself. The system can provide peer-to-peer connections between the DT700 series telephones with voice compression, offering existing IP telephone features with an enhanced user interface. On the WAN side, the system can provide peer-to-peer connections over IP networks with the voice compression on CCIS over IP. The SV8100 can provide legacy line/trunk interfaces to support the existing Time Division Multiplexing (TDM) based infrastructure, such as analog telephones, digital telephones (DT300 series), analog networks and digital networks (T1/E1, ISDN, etc.). The new compact 19” chassis provides 104 total ports (80 digital terminals) and can be expanded, using three additional 19” chassis, for a maximum of 416 ports (320 digital terminals). Through IP connection and four additional 19” chassis, the system can be expanded to a maximum of 512 ports for SV8100 and a maximum of 1024 for SV8300 (refer to Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels on page 2-5). Communications between legacy stations/trunks and DT700 series telephones/IP networks are made using a VoIP blade, which converts packet-based voice data to TDM-based voice data, and vice versa. Both peer-to-peer connections and TDM-based connections are controlled by the CPU blade. The CPU incorporates a built-in Device Registration Server (DRS) and a single interface point of IP connection to IP telephone, PCPro and OAI / ACD servers. Figure 1-1 shows a simplified view of SV8100 system connectivity.

1 - 2

Introduction to SV8100 Highlights of the UNIVERGE SV8100 are as follows: � Pure IP System capable TDM configuration The SV8100 supports both pure IP switching (peer-to-peer connections) and Time Division Switching. The pure IP switching is provided for communications between DT700 series telephones and for CCIS / Remote Unit connections with other SV8100. On the other hand, the TDM switching is provided for communications between legacy stations/trunks. Connection between IP network and legacy network is made via VoIP blade on the CPU blade, which converts packet-based voice data to TDM-based voice data, and vice versa. � Powerful CPU Blade with Built-in Functionalities The CPU blade of SV8100 is a heart of pure IP connections and TDM-based connections. The CPU blade employs a 32 bit microprocessor. With this processing power and DSP technology, it integrates the following functions on one board. These functions are managed with software licenses. � DTMF receivers � Caller ID receivers � Caller ID senders Figure 1-1 Simplified SV8100 System Connectivity

System Hardware Manual

1 - 3 � MF senders / receivers � 10/100 Ethernet Port � 2 Control Relays � MOH Input Port � Paging Output Port � In-Mail (VMDB) � VoIP. In addition, by means of advanced LSI technology, size of the CPU blade is minimized, O&M NIC port (10/100M) is built in and VoIPDB which has VoIP NIC port (Gigabit Ethernet) is mountable without additional slots in the chassis. The O&M NIC port is linked with LAN/WAN for inter-work with PCPro, SMDR, OAI server, and the VoIP NIC port is linked with LAN/WAN for control signaling and voice signaling (RTP) for DT700 series, etc. � High Density Legacy Line/Trunk Blades Major legacy line/trunk blades used in SV8100 are provided with main blade + daughter blade architecture. When the main blade is mounted only in an initial supply, line/trunk interfaces can be easily expanded by adding the daughter blade. The maximum number of ports for the line/trunk blades is 8/16 ports with daughter blade, respectively. This allows the physical system size to be compact. � Universal Blade Slot (19” Chassis) A 19” Chassis is used for legacy line/trunk blades. One 19” Chassis provides six universal slots and one expansion slot. Also, the universal slots can be used for special application blades without complicated limitation. This makes easy quotation and installation. � Easy Installation (Front Cabling and Enhanced O&M Tool) Cable connectors (RJ-45 or RJ-61) are located on the front panel of each chassis and blade. It increases efficiency of the cabling work. Also, PCPro provides an enhanced user interface. A Quick Setup tool provides easy setup (system data programming) for a basic system configuration in shorter time.

1 - 4

Introduction to SV8100 SECTION 2 EQUIPMENT LIST The following tables list all equipment for the SV8100 systems. Table 1-1 Chassis Equipment List Equipment Name Equipment Description Product Code CHS2U 19” Chassis (6-slot) SV8100 MPS7101 Power Supply Unit for 19” Chassis (2U) SV8100 Table 1-2 Chassis Installation Equipment List Equipment Name Equipment Description Product Code CHS2U BLANK SLOT COVER KIT Blank Slot Cover Set SV8100 CHS2U JOINT BRACKET KIT Upper Joint Bracket for 6-slot Chassis SV8100 CHS2U RACK MOUNT KIT Rack Mount for CHS2U Chassis SV8100 CHS1U/2U WALL MOUNT KIT Wall Mount Set for CHS2U Chassis SV8100 CHS Stand Kit (K) Stand Mount Kit for 2U Chassis SV8100 Table 1-3 Battery Mount Equipment List Equipment Name Equipment Description Product Code CHS1U BATT MTG KIT-A Built-in Battery Mount Kit (for 1U Chassis) for GS Yuasa PE12V-0.8 batteris (AMP connectors) or GS Yuasa NP0.8-12 batteries (JST connectors) SV8100 CHS1U BATT CA INT KIT (GS-NP) Cable set for internal battery SV8100 CHS LARGE BATT BOX Long Term Battery Box for CHS1U and CHS2U Chassis SV8100 CHS BATT CA EXT-A Cable set for external battery SV8100 CHS2U BATT MTG KIT Battery Mount for CHS2U Chassis SV8100

System Hardware Manual

1 - 5 Table 1-4 Blade Equipment List Equipment Name Abbreviations Equipment Description Product Code CD-CP00 CPU Main Processor Blade for KTS SV8100 PZ-BS10 BUS0 Expansion Chassis Interface Unit, 3-jack SV8100 PZ-BS11 BUS1 Expansion Chassis Interface Unit, 1-jack SV8100 PZ-VM21 VMDB 16 Channels for Voice Mail with a Single Channel V34 Modem SV8100 PZ-32IPLA VoIPDB 32-channel VOIP on CCPU SV8100 PZ-64IPLA VoIPDB 64-channel VOIP on CCPU SV8100 PZ-128IPLA VoIPDB 128-channel VOIP on CCPU SV8100 CD-8DLCA DLC 8-port Digital Station Interface SV8100 PZ-8DLCB DLCDB 8-port Digital Station Interface on CD-8DLCA SV8100 CD-16DLCA DLC 16-port Digital Station Interface SV8100 CD-4COTA COT 4-port Loop Start Trunks SV8100 PZ-4COTE COTDB 4-port Loop Start Trunks on CD-4COTA SV8100 CD-4LCA LC 4-port Single Line Telephone Interface SV8100 PZ-4LCA LCDB 4-port Single Line Telephone Interface on CD-4LCA and CD-8LCA SV8100 CD-8LCA LC 8-port Single Line Telephone Interface SV8100 PZ-8LCE LCDB 8-port Single Line Telephone Interface on CD-4LCA and CD-8LCA SV8100 CD-2BRIA BRT 2 Basic Rate Interface SV8100 PZ-2BRIA BRTDB 2 Basic Rate Interface on CD-2BRIA SV8100 CD-PRTA PRT 1 Primary Rate Interface SV8100 CD-4DIOPB DIOP 4 DID/OPX SV8100 CD-4ODTA ODT 4-port Tie Line Interface (E&M) SV8100 CD-RTB RTB Router (Future) SV8100 CD-ETIA GSWU PoE Gigabit Switch Unit SV8100 PZ-ME50 MEM Memory Expansion on CD-CP00 SV8100 CD-LTA LTA 8 Digital Station/2SLT for CD-CP00 only SV8100 CD-PVAA CNF Packet Voice Application (Future) SV8100

1 - 6

Introduction to SV8100 Table 1-5 Cable Equipment List Equipment Name Equipment Description Product Code RS CONSOLE CA-A MAT (PCPro) Cable 6.6 ft. (2.0m) SV8100 RS NORM-4S CA-F RS-232C Cable (normal) 13.1 ft (4m) SV8100 RS RVS-15S CA-F RS-232C Cable (reverse) 49.2 ft (15.0m) SV8100 RS RVS-4S CA-F RS 232C Cable (reverse) 13.1 ft (4.0m) SV8100 RS RVS-4S CA-G RS 232C Cable (reverse) 13.1 ft (4.0m) SV8100 RS PRT-15S CA-F RS-232C Cable (printer) 49.2 ft (15.0m) SV8100 BUS CABLE Bus Cable SV8100 AC CORD AC Power Cable for US SV8100 CHS2U BATT CA INT CHS2U Battery Cable for Internal Battery SV8100 CHS2U BATT CA EXT-A Battery Cable for External Battery 6-slot Chassis SV8100 Table 1-6 Digital Multiline Terminal (DT300 Series) Equipment List Equipment Name Equipment Description Product Code DTL-2E-1 (BK) TEL Economy Digital 2-button Telephone (No-Display) SV8100 DTL-6DE-1 (BK) TEL Economy Digital 6-button Display Telephone SV8100 DTL-12D-1 (BK) TEL DTL-12D-1 (WH) TEL Value Digital 12-button Display Telephone SV8100 DTL-24D-1 (BK) TEL DTL-24D-1 (WH) TEL Value Digital 24-button Display Telephone SV8100 DTL-32D-1 (BK) TEL DTL-32D-1 (WH) TEL Value Digital 32-button Display Telephone SV8100 DTL-12BT-1 (BK) TEL 12D + BCH (Future) SV8100 DTL-12PA-1 (BK) TEL Value Digital 12-button Telephone with Power Failure Adapter SV8100 DTL-8LD-1 (BK) TEL DTL-8LD-1 (WH) TEL Value Digital 8-button Telephone (DESI-less) SV8100 DCL-60-1 (BK) CONSOLE DCL-60-1 (WH) CONSOLE 60-button Direct Station Selection (DSS) Console SV8100

System Hardware Manual

1 - 7 8LK-L (BK) UNIT 8LK-L (WH) UNIT 8-button Line Key Unit SV8100 8LKD (LD)-L (BK) UNIT 8LKD (LD)-L (WH) UNIT DESI-less 8-button Line Key Unit/LCD Unit for Digital Telephone SV8100 Table 1-7 IP Multiline Terminal (DT700 Series) Equipment List Equipment Name Equipment Description Product Code ITL-2E-1 (BK) TEL Economy IP 2-button Telephone (No Display) SV8100 ITL-6DE-1 (BK) TEL Economy IP 6-button Display Telephone SV8100 ITL-12D-1 (BK) TEL ITL-12D-1 (WH) TEL Value IP 12-button Display Telephone SV8100 ITL-24D-1 (BK) TEL ITL-24D-1 (WH) TEL Value IP 24-button Display Telephone SV8100 ITL-32D-1 (BK) TEL ITL-32D-1 (WH) TEL Value IP 32-button Display Telephone SV8100 ITL-12PA-1 (BK) TEL Value IP 12-button Telephone with Power Failure Adapter SV8100 ITL-8LD-1 (BK) TEL ITL-8LD-1 (WH) TEL Value IP 8 Line Key Display Telephone Value IP Telephone: DESI-less SV8100 ITL-320C-1 (BK) TEL Sophisticated Telephone SV8100 8LKI (LD)-L (BK) UNIT 8LKI (LD)-L (WH) UNIT DESI-less LK/LCD Unit for IP SV8100 Table 1-8 DT300/DT700 Series Optional Equipment List Equipment Name Equipment Description Product Code APR-L UNIT APR SV8100 ADA-L UNIT ADA SV8100 BHA-L UNIT Bluetooth® Hub Adapter (Future) SV8100 PSA-L (BK) UNIT PSA-L (WH) UNIT PSA SV8100 BCH-L (BK) UNIT Bluetooth Cordless Handset (Future) SV8100 Table 1-6 Digital Multiline Terminal (DT300 Series) Equipment List (Continued) Equipment Name Equipment Description Product Code

1 - 8

Introduction to SV8100 12LK-L (BK) KIT 12LK-L (WH) KIT 12-button Line Key Kit SV8100 LCD (BL)-L (BK) UNIT LCD (BL)-L (WH) UNIT LCD Unit (No Backlight) SV8100 WM-L UNIT Wall Mount Unit SV8100 DESI ITL/DTL-2E (25 PKG) DESI Sheet for Economy 2-button Telephone (2 Labels per Sheet) SV8100 DESI ITL/DTL-6DE (25 PKG) DESI Sheet for Economy 6-button Display Telephone (2 Labels per Sheet) SV8100 DESI ITL/DTL-12D (25 PKG) DESI Sheet for Value 12-button Display Telephone (2 Labels per Sheet) SV8100 DESI ITL/DTL-8LK (25 PKG) DESI Sheet for 8-button Line Key (2 Labels per Sheet) SV8100 DESI DCL-60 (25 PKG) DESI Sheet for 60DSS (1 Label per Sheet) SV8100 DESI ITL/DTL-SIDE(25 PKG) DESI Sheet for Clear Side Panel (Left and Right Label each Sheet) SV8100 DESI ITL/DTL-SIDE- LCDV(25 PKG) DESI Sheet for Value Telephone LCD (Clear Side) SV8100 DESI ITL/DTL-SIDE- LCDS(25 PKG) DESI Sheet for Sophisticated Telephone LCD (Clear Side) SV8100 DESI ITL/DTL Directory Card Directory Card SV8100 DESI ITL/DTL-24D (25 PKG) DESI Sheet for Value 24-button Display Telephone (2 Labels per Sheet) SV8100 Panel (Red-Base)-L UNIT Color Side Panel for Base (Red) SV8100 Panel (Red-VLCD)-L UNIT Color Side Panel for Value Telephone LCD (Red) SV8100 Panel (Red-SLCD)-L UNIT Color Side Panel for Sophisticated Telephone LCD (Red) SV8100 Panel (Blue-Base)-L UNIT Color Side Panel for Base (Blue) SV8100 Panel (Blue-VLCD)-L UNIT Color Side Panel for Value Telephone LCD (Blue) SV8100 Panel (Blue-SLCD)-L UNIT Color Side Panel for Sophisticated Telephone LCD (Blue) SV8100 Panel (Silver-Base)-L UNIT Color Side Panel for Base (Silver) SV8100 Panel (Silver-VLCD)-L UNIT Color Side Panel for Value Telephone LCD (Silver) SV8100 Panel (Silver-SLCD)-L UNIT Color Side Panel for Sophisticated Telephone LCD (Silver) SV8100 Table 1-8 DT300/DT700 Series Optional Equipment List (Continued) Equipment Name Equipment Description Product Code

System Hardware Manual

1 - 9 Panel (Wood-Base)-L UNIT Color Side Panel for Base (Wood) SV8100 Panel (Wood-VLCD)-L UNIT Color Side Panel for Value Telephone LCD (Wood) SV8100 Panel (Wood-SLCD)-L UNIT Color Side Panel for Sophisticated Telephone LCD (Wood) SV8100 Panel( Logo-Base)-L UNIT Color Side Panel for Base (Wood with Logo) SV8100 Panel (Clear-Base)-L UNIT Color Side Panel for Base (Clear) SV8100 LKPANEL(2BTN)-L (BK) UNIT Spare Plastic Cover Kit (2-button) (BK) SV8100 LKPANEL(6BTN)-L (BK) UNIT Spare Plastic Cover Kit (6-button) (BK) SV8100 LKPANEL(12BTN)-L (BK) UNIT LKPANEL(12BTN)-L (WH) UNIT Spare Plastic Cover Kit (12-button) SV8100 LKPANEL(24BTN)-L (BK) UNIT LKPANEL(24BTN)-L (WH) UNIT Spare Plastic Cover Kit (24-button) SV8100 LKPANEL(8BTN)-L (BK) UNIT LKPANEL(8BTN)-L (WH) UNIT Spare Plastic Cover Kit (8-button) SV8100 LKPANEL(60BTN)-L (BK) UNIT LKPANEL(60BTN)-L (WH) UNIT Spare Plastic Cover Kit (60-button) SV8100 DTL (Value)-Base-1 unit Digital Base SV8100 LCDD(S)-L (BK) UNIT LCDD(S)-L (WH)) UNIT Digital Standard Telephone LCD SV8100 TENKEY(STD)-L SET Standard 10-Key SV8100 FNCKEY(STD)-L (BK) SET FNCKEY(STD)-L (WH) SET Standard Function Key SV8100 12LKSoft-L (BK) SET 12LKSoft-L (WH) SET 12LK without Soft Key SV8100 12LK(STD)-L (BK) SET 12LK(STD)-L (WH) SET 12LK SV8100 Table 1-8 DT300/DT700 Series Optional Equipment List (Continued) Equipment Name Equipment Description Product Code

1 - 10

Introduction to SV8100 TKPANEL(STD)-L (BK) UNIT TKPANEL(STD)-L (WH) UNIT 10-Key Panel SV8100 Cradle (STD)-L(BK) Cradle (STD)-L(WH) Cradle SV8100 VAL DIRECTORY CARD UNIT(L) Directory Card Holder for Value Telephone SV8100 ECO DIRECTORY CARD UNIT(L) Directory Card Holder for Economy Telephone SV8100 Panel (Clear-VLCD)-L UNIT Color Side Panel for Value Telephone LCD (Clear) SV8100 Panel (Clear-SLCD)-L UNIT Color Side Panel for Sophisticated Telephone LCD (Clear) SV8100 LKPANEL(16BTN)-L (BK) UNIT LKPANEL(16BTN)-L (WH) UNIT Spare Plastic Cover Kit (16-button) SV8100 KeyKitPanel (Value) (BK) Unit KeyKitPanel (Value) (WH) Unit Spare Plastic Cover Key Kit for Value Telephone SV8100 KeyKitPanel (Retro) (BK) Unit KeyKitPanel (Retro) (WH) Unit Spare Plastic Cover Key Kit for Retro Telephone SV8100 KeyKitPanel (Sophi) (BK) Unit KeyKitPanel (Sophi) (WH) Unit Spare Plastic Cover Key Kit for Sophisticated Telephone SV8100 BS (F)-L (BK) KIT BS (F)-L (WH) KIT French Keypad SV8100 BS (S)-L (BK) KIT BS (S)-L (WH) KIT Spanish Keypad SV8100 ITL-GigADP-1 Gigabit Adapter (Future) SV8100 Table 1-8 DT300/DT700 Series Optional Equipment List (Continued) Equipment Name Equipment Description Product Code

System Hardware Manual

2 - 1 Chapter 2 SV8100 System Specifications SECTION 1 GENERAL INFORMATION This chapter provides detailed specifications for the SV8100 system technician. The technician should review this information carefully before installing the system. SECTION 2 SYSTEM BLOCK DIAGRAM Figure 2-1 SV8100 System Block Diagram shows the Blades that can be installed in the chassis and the number of channels supported when the Blade is installed. Table 2-1 List of Abbreviations lists abbreviations used in the diagram. Table 2-1 List of Abbreviations Abbreviation Description ACD Automatic Call Distribution ADA Analog Recording Adapter APR Analog Port Adapter (with ringer) BCH Bluetooth Cordless Handset BHA Bluetooth Hub Adapter AUX IN/OUT BGM/MOH Port (on CPU) BRI Basic Rate Interface BRIDB Expansion Basic Rate Interface Blade on BRI BRT Basic Rate Interface Blade/ISDN Terminal Interface Blade BUS0 BUS Interface Blade (for 1U chassis) BUS1 BUS Interface Blade (for 2U chassis) CCT CCIS Interface Blade CF Compact Flash CFT Conference Trunk (on CPU)

2 - 2

SV8100 System Specifications CNF Conference Bridge Blade (PVA) CPU Central Processing Unit DID Direct Inward Dialing DIOP DID/OPX Blade DLC Digital Multiline Terminal Interface Blade DLCB Expansion Digital Multiline Terminal Interface Blade on DLC DRS Device Registration Server (on CPU) DSS Direct Station Selection Console DTI Digital Trunk Interface DTG Digital Tone Generator (on CPU) ETHERNET Ethernet Port (on CPU) FT1 Fractional T1 GSWU Power over Ethernet Gigabit Switch IDF Intermediate Distribution Frame IPT IP Trunk (P2P CCIS) (on CPU) ISDN Integrated Service Digital Network LAN Local Area Network LC Single Line Telephone Interface Blade LCDB Expansion Single Line Telephone Interface Blade on LC MDF Main Distribution Frame MEM Main Memory (on CPU) MIS Management Information System MOH Music On Hold OAI Open Application Interface (on CPU) ODT Tie Line Interface Blade (2W/4W E&M) OPX Off-Premise Extension PBR PB Receiver (on CPU) PBSND PB Sender (on CPU) PCPro PC Programming Table 2-1 List of Abbreviations (Continued) Abbreviation Description

System Hardware Manual

2 - 3 PFT Power Failure Transfer PLO Phase Locked Oscillator (on CPU) PMS Property Management System PRI Primary Rate Interface PRT Primary Rate Interface Blade PS Personal Station PSA PSTN Adapter (analog) PVA Packet Voice Application RTB Router Blade SERIAL Serial Port (on CPU) SLT Single Line Telephone SMDR Station Message Detail Recording TDSW Time Division Switch (on CPU) USB Universal Serial Bus (on CPU) VM00 UMS Blade Server Blade (SV8100 only) VMDB VMS Daughter Board with V34 Modem (SV8100 only) VMS Voice Mail System VoIP Voice over Internet Protocol VoIPDB VoIP Blade (on CPU) VRS Voice Response System WAN Wide Area Network WebPro Web-Based PC Programming Table 2-1 List of Abbreviations (Continued) Abbreviation Description

2 - 4

SV8100 System Specifications Figure 2-1 SV8100 System Block Diagram

System Hardware Manual

2 - 5 SECTION 3 MAXIMUM SYSTEM CAPACITIES The CHS2U is a compact 19” chassis that has six universal slots, one expansion slot and one MPS7101 (power supply unit). When the CD-CP00 is installed in the first CHS2U, it is referred to as the Controlling Chassis. Additional chassis, referred to as Expansion Chassis, can be installed to increase the capacity of the system to meet the customer’s business needs. As Figure 2-2 19” Controlling and Expansion Chassis and Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels illustrate, the system can be expanded from 104 ports to 512 ports by vertically stacking a maximum of three additional chassis onto the controlling chassis. This provides a maximum of 24 slots and 320 digital terminals. To obtain a the maximum port capacity of 512 ports, two systems can be linked together via an IP connection. The maximum slot and channel capacities are listed in Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels. Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels Number of: 19” Chassis System Maximum x 1 (6 Slots) x 2 (12 Slots) x 3 (18 Slots) X4 (24 Slots) Number of Timeslots 111 222 333 444 444 Number of TDM (Time Division Multiplexing) Ports 104 208 312 416 416 Dterm (-48V) *1 80 160 240 320 Total 512 SLT (-24V) 80 176 272 368 SLT (-48V) 20 44 68 92 DtermIP 512 SIP/WLAN 512 Analog Trunks (COT) 40 88 136 184 Total 200 BRI 40 88 136 184 PRI 90 180 180 180 IP Trunk (SIP) 200 VoIP Channels 128

2 - 6

SV8100 System Specifications 3.1 System Configuration – SV8100 The SV8100 19” chassis provides 104 total ports (80 digital terminals) and can be expanded, using three additional 19” chassis, for a maximum of 416 ports (320 digital terminals). Through IP connection and use of additional 19” chassis, the system can be expanded to a maximum of 512 ports. The 19” chassis consists of a controlling chassis (chassis with CPU blade), and the ability to expand the system using expansion blades depending on system configuration. Voice Mail Channels on CPU 16 channels V90 Modem 1 channel *1 = Maximum 80 Digital Terminals per 19” chassis due to power consumption Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels Number of: 19” Chassis System Maximum x 1 (6 Slots) x 2 (12 Slots) x 3 (18 Slots) X4 (24 Slots)

System Hardware Manual

2 - 7 Figure 2-2 19” Controlling and Expansion Chassis 6 Slots 18 Slots IP Connection 24 Slots

2 - 8

SV8100 System Specifications Table 2-3 Maximum System Capacities – Chassis shows the maximum number of chassis and related equipment that can be installed in a system. Table 2-3 Maximum System Capacities – Chassis Hardware 19” Chassis with CPU 19” Chassis without CPU 19” Chassis x4 Comments Number of Slot(s) for Interface Package 5 Slots 6 Slots 23 Slots Chassis: CHS2U (19” Chassis) 1 3 4 Virtual slot in NetLink is limited to maximum of 240 Expansion: PZ-BS10 3-jack Expansion Board for Controlling Chassis 1 0 0 – PZ-BS11 1-jack Expansion Board for Expansion Chassis 0 1 3 – Battery: CHS LARGE BATT BOX (External Battery Box) 1 1 4 – Fan Box: CHS2U FAN BOX SET 1 1 4 1 is factory installed with each chassis Power Supply: MPS7101 1 2 4 1 is factory installed with each chassis

System Hardware Manual

2 - 9 Table 2-4 Maximum System Capacities – Blades shows the maximum number for each blade that can be installed in a system. This is determined by the maximum blade configuration allowed. When installing single line sets, DISA, or tie lines, CPU circuits must be allocated for DTMF receivers. To install single line sets with CO/PBX line access, or when installing immediate-start tie lines, CPU circuits must be allocated for dial tone detection. Table 2-4 Maximum System Capacities – Blades Hardware 19” Chassis with CPU 19” Chassis without CPU 19” Chassis x4 Comments Number of Slot(s) for Interface Package 5 Slots 6 Slots 23 Slots Common Control Blades: CD-CP00 1 0 0 – PZ-32IPLA (32-port VoIP Daughter Board) 1 0 0 This unit provides 32 VOIP Gateway channels PZ-64IPLA (64-port VoIP Daughter Board) 1 0 0 This unit provides 64 VOIP Gateway channels PZ-128IPLA (128-port VoIP Daughter Board) 1 0 0 This unit provides 128 VOIP Gateway channels PZ-ME50 (Memory Expansion Board) 1 0 0 – PZ-VM21 (Voice Mail Daughter) 1 0 0 Does include modem Station Blades: CD-4DIOPB (4 DID/OPX) 5 6 23 When installed as an OPX blade CD-4LCA (4 Single Line Telephone Interface) 5 6 23 – PZ-4LCA (4 Single Line Telephone Interface Daughter Board) 5 6 23 – CD-8DLCA (8 Digital Station Interface) 5 6 23 Maximum of 80 Digital Terminals per chassis PZ-8DLCB (8 Digital Station Interface Daughter Board) 5 5 20 Maximum of 80 Digital Terminals per chassis

2 - 10

SV8100 System Specifications CD-8LCA (8 Single Line Telephone Interface) 5 6 23 Maximum of 80 Analog Terminals per chassis PZ-8LCE (8 Single Line Telephone Interface Daughter Board) 5 5 20 Maximum of 80 Digital Terminals per chassis CD-16DLCA (16 Digital Station Interface) 5 5 20 Maximum of 80 Analog Terminals per chassis CD-LTA (8 Digital/2 Single Line) 1 1 4 An optional PZ-4COTE or PZ-2BRIA can be installed Trunk Blades: CD-2BRIA (2 Basic Rate Interface) 5 6 23 – PZ-2BRIA (2 Basic Rate Interface Daughter Board) 5 6 23 – CD-4COTA (4 Loop Start Trunk) 5 6 23 – PZ-4COTE (4 Loop Start Trunk Daughter Board) 5 6 23 – CD-4DIOPB (4 DID/OPX) 5 6 23 When installed as a DID blade CD-4ODTA (4 E&M) 5 6 23 – CD-PRTA (1 Primary Rate Interface) 3 3 6 This blade is used for Primary Rate Interface. Optional Blades: CD-PVAA (Conference Bridge) 5 6 23 R2 CD-ETIA (Switching Hub with Power over Ethernet) 3 3 12 – CD-RTB (Router) 1 2 1 R2 Table 2-4 Maximum System Capacities – Blades (Continued) Hardware 19” Chassis with CPU 19” Chassis without CPU 19” Chassis x4 Comments Number of Slot(s) for Interface Package 5 Slots 6 Slots 23 Slots

System Hardware Manual

2 - 11 PZ-BZ10 (for Controlling Chassis) 1 0 0 – PZ-BZ11 (for Expansion Chassis) 0 1 3 – Table 2-4 Maximum System Capacities – Blades (Continued) Hardware 19” Chassis with CPU 19” Chassis without CPU 19” Chassis x4 Comments Number of Slot(s) for Interface Package 5 Slots 6 Slots 23 Slots

2 - 12

SV8100 System Specifications Table 2-5 Daughter Board Combinations shows each blade and associated daughter board combinations. The daughter boards that can be mounted on specific blades are indicated by a checkmark. For example, the CD-LTA can have a PZ-2BRIA or the PZ-4COTE daughter board mounted. Table 2-5 Daughter Board Combinations Daughter Board PZ-2BRIA PZ-4COTE PZ-4LCA PZ-8LCE PZ-8DLCB Controlling Chassis CD-LTA (8 Digital/2 Single Line) 4 4 – – – CD-4COTA (4 Loop Start) – 4 – – – CD-4LCA (4 Single Line Interface) – – 4 4 – CD-8LCA (8 Single Line Interface) – – 4 4 – CD-8DLCA (8 Digital Station Interface) – – – – 4 CD-16DLCA (16 Digital Station Interface) – – – – – CD-2BRIA (2 Basic Rate Interface) 4 – – – – – = Does not apply 4 = Does apply

System Hardware Manual

2 - 13 SECTION 4 POWER-BASED CALCULATOR CHART The Univerge SV8100 system uses two types of power factors. For a single chassis chart refer to Table 2-6 Board Power Factor. For the maximum number of specific blades per package, see Table 2-7 Maximum Number of Package Installed. Refer to Table 2-8 Terminal Power Factor below, for the Terminal/ Adapter power chart. Table 2-6 Board Power Factor Board Power Factor Total =<7 Item Power Factor CD-CP00 1 CD-RTB 2 CD-VM00 2 CD-ETIA 2 CD-PVAA 1 PZ-32IPLA 1 PZ-64IPLA 2 PZ-128IPLA 2 Table 2-7 Maximum Number of Package Installed Board (Power Factor) Maximum Number of Package Installed 19 inch with CCPU 19 inch without CCPU 4 x 19 inch CD-ETIA (2) 3 3 12 CD-PVAA (1) 5 6 23 CD-RTB (2) 2 2 8

2 - 14

SV8100 System Specifications Table 2-8 Terminal Power Factor Terminal Power Factor 19 inch Chassis =<80 Item Power Factor DTL-24D-1 TEL 1 DTL-8LD-1 TEL 1.5 BHA-L Unit 2 ADA-L UNIT 2 APR-L UNIT 2 BCH-L (BK) UNIT 2 Power Save Adapter 1 8LK-L UNIT 0 DCL-60-1 CONSOLE 2 ITL-320C-1 TEL 6 ITL-24D-1 TEL 4 ITL-2E-1 TEL 4 ITL-6DE-1 TEL 4 SLT 1 PGD(2)-U10 ADP 2 SLT Adapter 5 . ITL factors are calculated using the CD-ETIA blade. Table 2-9 IP Terminal Power Chart IP Terminal IEEE802. 3af Class Label Indication (Maximum Current with All Options) Maximum Current Without Options 48VDC 24VDC 48VDC 24VDC ITL-320C-1 TEL Class 3 160mA 7.7W 290mA 7.0W 111mA 5.3W 192mA 4.6W ITL-32D-1 TEL Class 2 130mA 6.2W 235mA 5.6W 90mA 4.3W 153mA 3.7W ITL-8LD-1 TEL Class 2 130mA 6.2W 235mA 5.6W 81mA 3.9W 137mA 3.3W

System Hardware Manual

2 - 15 ITL-24D-1 TEL Class 2 130mA 6.2W 235mA 5.6W 81mA 3.9W 137mA 3.3W ITL-12D-1 TEL Class 2 130mA 6.2W 235mA 5.6W 81mA 3.9W 137mA 3.3W ITL-24PA-1 TEL Class 2 130mA 6.2W 235mA 5.6W – 0.0W – 0.0W ITL-24PD-1 TEL Class 2 130mA 6.2W 235mA 5.6W – 0.0W – 0.0W ITL-24BT-1 TEL Class 2 130mA 6.2W 235mA 5.6W – 0.0W – 0.0W ITL-6DE-1 TEL Class 1 68mA 3.3W 122mA 2.9W 68mA 3.3W 122mA 2.9W ITL-2E-1 TEL Class 1 68mA 3.3W 122mA 2.9W 68mA 3.3W 122mA 2.9W Label Indication: IP Value/Sophisticated – Maximum watts when adding options or modular upgrades. IP Value – Maximum watts when ITL-12D-1 TEL is changed to ITL-8LD-1 TEL or ITL-24D-1 TEL. Table 2-9 IP Terminal Power Chart (Continued) IP Terminal IEEE802. 3af Class Label Indication (Maximum Current with All Options) Maximum Current Without Options 48VDC 24VDC 48VDC 24VDC Table 2-10 IEEE802.af Class Specifications IEEE802.3af Minimum Maximum Class 4 – – Class 3 6.49W 12.95W Class 2 3.84W 6.49W Class 1 0.44W 3.84W Class 0 0.44W 12.95W

2 - 16

SV8100 System Specifications SECTION 5 SYSTEM REQUIREMENTS AND SPECIFICATIONS 5.1 Cabling This section provides cabling requirements and specifications for various equipment used in the SV8100 system. Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable is a diagram of the chassis connected with each of the multiline terminals and single line telephones by a separate twisted 1-pair cable or 2-pair cable (only for Multiline Terminals). Refer to the following tables for cabling requirements and specifications. � Table 2-11 DT300 Series Loop Resistance and Cable Length � Table 2-12 DT700 Series Loop Resistance and Cable Length � Table 2-13 Dterm Series i or Dterm IP Terminal Loop Resistance and Cable Length � Table 2-14 Cable Connection Between the Analog Port and the Single Line Equipment � Table 2-15 Cabling Requirements Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable Table 2-11 DT300 Series Loop Resistance and Cable Length Terminal or Adapter By Twisted 1-Pair Cable (without AC Adapter) 24 AWG DTL-2E-1 (BK) TEL 1,969 ft (600m) DTL-6DE-1 (BK) TEL 1,969 ft (600m) DTL-8LD-1 (BK) TEL DTL-8LD-1 (WH) TEL 1,969 ft (600m) DTL-12BT-1 (BK) TEL 1,969 ft (600m) DTL-12PA-1 (BK) TEL 1,969 ft (600m) DTL-12D-1 (BK) TEL DTL-12D-1 (WH) TEL 1,969 ft (600m) Multiline Terminal Twisted 2-Pair Cable DLC RJ-11

System Hardware Manual

2 - 17 DTL-24D-1(BK) TEL DTL-24D-1(WH) TEL 1,969 ft (600m) DTL-32D-1 (BK) TEL DTL-32D-1 (WH) TEL 1,969 ft (600m) DCL-60-1 Console* 1,969 ft (600m) * An AC Adapter is required. Table 2-12 DT700 Series Loop Resistance and Cable Length Terminal or Adapter Ethernet Cable ITL-2E-1 (BK) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m) ITL-6DE-1 (BK) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m) ITL-8LD-1 (BK) TEL ITL-8LD-1 (WH) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m) ITL-12BT-1 (BK) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m) ITL-12D-1 (BK) TEL ITL-12D-1 (WH) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m) ITL-12PA-1 (BK) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m) ITL-24D-1 (BK) TEL ITL-24D-1 (WH) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100 m) ITL-32D-1 (BK) TEL ITL-32D-1 (WH) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m) ITL-32OC-1 (BK) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m) Table 2-11 DT300 Series Loop Resistance and Cable Length (Continued) Terminal or Adapter By Twisted 1-Pair Cable (without AC Adapter) 24 AWG

2 - 18

SV8100 System Specifications Table 2-13 Dterm Series i or Dterm IP Terminal Loop Resistance and Cable Length Terminal or Adapter Maximum Loop Resistance (without AC Adapter) (Ohms) By Twisted 1-Pair Cable (without AC Adapter) 24 AWG By Twisted 2-Pair Cable (without AC Adapter) 24 AWG Maximum Loop Resistance (with AC Adapter) (Ohms) By Twisted 1-Pair Cable (with AC Adapter) 24 AWG By Twisted 2-Pair Cable (with AC Adapter) 24 AWG DTH-8-1 TEL DTR-8-1 TEL 37 700 1400 107 2000 2000 DTH-8D-1 TEL DTR-8D-1 TEL 37 700 1400 107 2000 2000 DTH-16-1 TEL DTR-16-1 TEL 35 660 1320 107 2000 2000 DTH-16D-1 TEL DTR-16D-1 TEL 35 660 1320 107 2000 2000 DTH-32D-1 TEL DTR-32D-1 TEL 26 500 1000 107 2000 2000 DTH-16LD-1 TEL 37 700 1400 107 2000 2000 DCR-60-1 Console* — — — 107 2000 2000 * An AC Adapter is required. Table 2-14 Cable Connection Between the Analog Port and the Single Line Equipment Connected Equipment Cable Maximum Feet from Connected Equipment to Telephone ADA-L UNIT Twisted Pair 10 ft (3.048m) APR-L UNIT Twisted Pair 50 ft (15.24m) PSA-L (BK) UNIT Twisted Pair 1,700 ohms PSA-L (WH) UNIT Twisted Pair 1,700 ohms . Mixing digital and analog ports through the same 25-pair cable runs is not recommended.

System Hardware Manual

2 - 19 5.2 Power Requirements A dedicated 230VAC 50 Hz circuit located within seven feet of the chassis is required. A separate dedicated outlet for each chassis should be installed. 5.2.1 Power Supply Specifications AC Power Supply: � Dedicated 15 Amp circuit � Power Requirements: 230 VAC @ 15A Controlling/Base Chassis � Power Consumption: Base Chassis=265VA, Expansion Chassis=265VA, total 1060VA � Input Voltage: 90VAC to 264VAC (Rated Voltage: 100VAC/120VAC/220VAC - 240VAC) � Frequency: 45Hz - 66Hz (Rated frequency: 50/60Hz) � Phase and Wire: Single Phase, 2 Line + PE Type � Grounding Requirements: No. 14 AWG copper wire � Feeding Voltage: Dterm/OPX/DID: -48V SLT: 25mA / -28V With input voltage of 230 VAC and with full load conditions: Output Power: Base chassis=130W, Expansion chassis=130W, total 520W AC Input I: Base chassis=1.15A, Expansion chassis=1.15A, total 4.6A VA @ 220V: Base chassis=265VA, Expansion chassis=265VA, total 1060VA Table 2-15 Cabling Requirements Connected Equipment Cable Music on Hold and Background Music Sources Hi-Fi Shielded Audio Cable External Amplifier Hi-Fi Shielded Audio Cable ITL Cabling Cat 5 Straight Data Network Cable – 328.1 ft (100m) maximum distance. Double Pole/Neutral Fusing (power supply fuses are located at both the L and N side).

2 - 20

SV8100 System Specifications KWh @ AC Input I x 230V/1000: Base chassis=0.265 KWh, Expansion chassis=0.265 KWh, total 1.060 KWh BTU (KWh x 3413): Base chassis=904 BTU, Expansion chassis=904 BTU, total 3616 BTU � Dedicated 230 Vac � 50/60 Hz circuit located within seven feet of the chassis � Dedicated 15A circuit � Single Phase � A dedicated outlet, separately fused and grounded for each chassis should be installed 5.2.2 Power Supply Consumption 5.3 Environmental Conditions 5.3.1 Temperature and Humidity Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR � Operating Temperature: 0°C ~ 40°C � Recommended Long Term Temperature: -20°C ~ 60°C � Operating Humidity: 10 ~ 90% RH (non-condensing) Table 2-16 Power Consumption Chassis Maximum RMS Current Watts Used (Idle) Watts Used (Maximum) Basic Chassis – CD-CP00 Chassis 1.15 A 96 130 Basic Chassis + Expansion Chassis 2.3 A 192 260 Basic Chassis + 2 Expansion Chassis 3.45 A 288 390 Basic Chassis + 3 Expansion Chassis 4.6 A 384 520 Double Pole/Neutral Fusing (power supply fuses are located at both the L and N side). Double Pole/Neutral Fusing (power supply fuses are located at both the L and N side).

System Hardware Manual

2 - 21 � Recommended Long Term Humidity: 10 ~ 90% RH Blades – PZ-BS10, PZ-BS11, PZ-VM21, PZ-ME50, CD-8DLCA, CD-16DLCA, PZ-8DLCB � Operating Temperature: 0oC ~ 40oC � Recommended Long Term Temperature: -20°C ~ 60°C � Humidity: 10 ~ 90% RH (non-condensing) � Recommended Long Term Humidity: 10 ~ 90% RH Blades - CD-4LCA, PZ-4LCA, CD-8LCA, PZ-8LCE, CD-4COTA, PZ-4COTE, CD-PRTA � Operating Temperature: 0°C ~ 40°C � Recommended Long Term Temperature: -20°C ~ 60°C � Operating Humidity: 10 ~ 90% RH (non-condensing) � Recommended Long Term Humidity: 20 ~ 90% RH Door Box � Operating Temperature: -20oC ~ 60oC � Operating Humidity: 20 ~ 80% (non-condensing) SV8100 Power Supply – MPS7101 � Operating Temperature: 0oC ~ +40oC � Recommended Long Term Temperature: -40oC ~ 75oC � Operating Humidity: 20 ~ 95% RH (non-condensing) � Recommended Long Term Humidity: 10 ~ 95% RH 5.4 Outside Line Types The following outside lines can be used with the UNIVERGE SV8100 system. � 4-wire, E&M Tie Lines (Type I or V, Dial Pulse, or DTMF) � Digital Trunk T1/FT1 (Loop Start, Tie Line (E&M), or DID Signaling) � ISDN-BRI Trunks � ISDN-PRI Trunks � VoIP Trunks (Internet Protocols) 5.5 Transmission, Network, and Control Specifications 5.5.1 Transmission � Data Length:

2 - 22

SV8100 System Specifications From Multiline Terminal to CD-8DLCA: 23 bits From CD-8DLCA to Multiline Terminal: 23 bits � Data Transmission Rates: Between CD-8DLCA and Multiline Terminal: 184K bps (voice and signaling) � Scanning Time for each Multiline Terminal: 32 ms. 5.5.2 Network Time Division Multiplexing (TDM) allows transmission of data and voice simultaneously over one communications medium. The specifications that the UNIVERGE SV8100 system uses for switching, clock, data bus, and timeframe are shown below. � TDM Switching: PCM (µ Law) � TDM Clock: 2.048 MHz � TDM Data Bus: 8 bit � TDM Timeframe: 125 µs. 5.5.3 Control This section indicates the speed or capacity: � Control: Stored program with distributed processing � Central Processor: 32-bit microprocessor � Clock: 266 MHz � Interface Blade: 8- or 16-bit microprocessor � Optional Blades: 16- or 32-bit microprocessor � Multiline Terminal (TDM): 8-bit microprocessor � Multiline Terminal (IP): 32-bit microprocessor � IP Adapter: 32-bit microprocessor � Attendant Console: 4-bit microprocessor � SLT Adapter: 4-bit microprocessor

System Hardware Manual

2 - 23 5.5.4 Electra Elite IPK Terminals and Equipment The voltage, current, and ring signal for the Electra Elite IPK Multiline Terminals, Single Line Telephone equipment, and AP(A)-R/AP(R)-R Units are listed below: � Multiline Terminal Voltage: -11 ~ -26 Vdc Maximum Current: 250 mA � Single Line Telephone Standard 2500 Set: 500 type network Nominal Current: 25 mA Ring Signal: 56 Vac RMS @ 20 Hz � SLTII(1)-U( ) ADP Standard 2500 Set: 500 type network Nominal Current: 30 mA Ring Signal: 56 Vac RMS @ 20 Hz � AP(A)-R Unit Standard 2500 Set: 500 type network Nominal Current: 30 mA � AP(R)-R Unit Standard 2500 Set: 500 type network Nominal Current: 30 mA Ring Signal: 56 Vac RMS @ 20 Hz Acoustical characteristics meet Electronic Industry Association (EIA) standard proposal SP-1286 and standard EIA RS-470.

2 - 24

SV8100 System Specifications 5.5.5 Series i Terminals � The voltage and current for the Dterm Series i Multiline Terminals are listed below: Voltage: -11 ~ -48 Vdc Maximum Current: 250 mA � Voltage, current, and ring signal information for Single Line Telephone equipment, AP(A)-R Unit, and AP(R)-R Unit are the same a those listed in the previous paragraph. 5.6 Dialing Specifications 5.6.1 Dial Pulse Address Signaling Dial Pulse Address Signaling uses dial pulses (regular momentary interruptions) to signal the equipment. The following Dial Pulse specifications are used In the UNIVERGE SV8100 system. � Pulse Rate: 10 ± 0.5 pps/20 ± 1.0 pps � Percent Break: 60 ± 1.5% � Interdigit Interval: 0 pps/20 pps 770 ms. ~ 830 ms. 5.6.2 Dual-Tone Multifrequency (DTMF) Address Signaling DTMF signaling includes push button or Touchtone dialing. When a key on a telephone is pushed, two tones (one high frequency and one low frequency) are provided. In the UNIVERGE SV8100 system, the following DTMF specifications are used. � Frequencies Two sinusoidal frequencies are provided, one from the high frequency group and one from the low frequency group. � Frequency Deviation: Less than ±1.5% � Signal Level: Nominal level per frequency: -6 ~ -4 dBm Minimum level per frequency Low Group: -10 dBm High Group: -8 dBm Maximum level per frequency: 0 dBm Acoustical characteristics meet Electronic Industry Association (EIA) standard proposal SP-1286 and standard EIA RS-470.

System Hardware Manual

2 - 25 � Rise Time: Within 5 ms. � Duration of Dual Frequency Signal: 110 ms. default/60 ms. minimum Interdigital Time: 140 ms. default/45 ms. minimum 5.6.3 External Equipment Connection � Door Phone or TV Door Phone � External Speaker via amplifier � External music source for MOH and BGM � Tape recorder for voice recording via PGD(2)-U10 ADP � Door Lock/Release or General Purpose Relay via PGD(2)-U10 ADP � Printer for SMDR by LAN � PC by LAN 5.6.4 Music Source for Music on Hold via Chassis � Auxiliary Input: 0.6V PPS Signal Level � Input Impedance: 600 Ω 5.6.5 Music Source for Station Background Music via ACI � Auxiliary Input: 0.6V PPS Signal Level � Input Impedance: 600 Ω 5.6.6 External Paging (Audio) � Output Power: –10 dBm Signal Level � Output Impedance: 600 Ω � Relay Contact Rating: 500 mA, 24 Vdc 1209 1336 1477 697 1 2 3 770 4 5 6 852 7 8 9 941 Q 0 # Nominal Low Group Frequencies (Hz) Nominal High Group Frequencies (Hz)

2 - 26

SV8100 System Specifications 5.6.7 External Tone Ringer/Night Chime Output � Output Level: –10 dBm � Output Impedance: 600 Ω � Relay Contact Rating: 500 mA, 24 Vdc 5.6.8 SMDR Output � Female Connector (LAN) Standard DB-9 (straight) 5.6.9 PC Connection � Female Connector (LAN) Standard DB-9 (straight) 5.6.10 Relay Contact � All Relay Contact Ratings: 500 mA, 24Vdc 5.7 Battery Backup The UNIVERGE SV8100 system has battery backup functions for system backup and for memory backup. 5.7.1 System Backup (Optional) During a power failure, the system can be backed up using the CHS2U BATT MTG KIT for a backup time of 10 minutes or one of the CHS LARGE BATT SETs for a backup time ranging from 45~180 minutes. 5.7.2 Memory Backup The CD-CP00 Blade battery retains the Clock/Calender and Last Number redial (LNR) buffers for each station when the CD-CP00 Blade encounters a power loss. With a fully charged battery, the settings are retained for about three years. The System Programmed memory (Customer Database) is stored in non-volatile Memory and can be erased only by a First Initialization. After power is restored, the system Blade returns to normal operation.

System Hardware Manual

2 - 27 5.8 Weights and Dimensions Table 2-17 SV8100 Weights and Dimensions on page 2-27 shows the shipping weight, height, width and depth of each SV8100 digital multiline terminal, IP multiline terminal, Dterm, Series i multiline terminal, chassis, assorted blades and adapters. Table 2-17 SV8100 Weights and Dimensions Unit Shipping Weight 1 Height Width Depth SV8100 CHS2U 278.7 oz (7.9 kg) 3.47 in (88 mm) 16.9 in (430 mm) 14.17 in (360 mm) CD-CP00 7.06 oz (0.2 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.09 in (180 mm) PZ-ME50 .353 oz (0.01 kg) 0.12 in (3 mm) 2.56 in (65 mm) 1.22 in (31 mm) CD-LTA 6.70 oz (0.19 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.09 in (180 mm) CHS LARGE BATT BOX 352.7 oz (10 kg) 23.23 in (590 mm) 17.72 in (450 mm) 10.43 in (265 mm) CHS LARGE BATT SET 194 oz (5.5 kg) 6.69 in (170 mm) 5.91 in (150 mm) 4.33 in (110 mm) Common MPS7101 31.75 oz (0.9 kg) 2.36 in (60 mm) 7.08 in (180 mm) 6.10 in (155 mm) PZ-BS10 2.29 oz (.065 kg) 0.91 in (23 mm) 2.17 in (55 mm) 7.28 in (185 mm) PZ-BS11 1.975 oz (0.056 kg) 0.91 in (23 mm) 2.17 in (55 mm) 7.28 in (185 mm) PZ-VM21 1.76 oz (0.05 kg) 0.60” (15 mm) 2.09 in (53 mm) 3.35 in (85 mm) PZ-32IPLA 1.76 oz (0.05 kg) 0.60 in (15 mm) 3.15 in (80 mm) 6.3 in (160 mm) PZ-64IPLA 1.76 oz (0.05 kg) 0.60 in (15 mm) 3.15 in (80 mm) 6.3 in (160 mm) PZ-128IPLA 1.76 oz (0.05 kg) 0.60 in (15 mm) 3.15 in (80 mm) 6.3 in (160 mm) CD-8DLCA 5.89 oz (0.167 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.09 in (180 mm) PZ-8DLCB 4.41 oz (0.125 kg) 0.60 in (15 mm) 4.72 in (120 mm) 5.12 in (130 mm)

2 - 28

SV8100 System Specifications CD-16DLCA 7.831 oz (0.222 kg) 1.89 in (48 mm) 9.45 in (240 mm) 7.68 in (195 mm) CD-4COTA 6.35 oz (0.18 kg) 1.89 in (48 mm) 9.45 in (240 mm) 7.68 in (195 mm) PZ-4COTE 3.53 oz (0.10 kg) 1.89 in (48 mm) 9.45 in (240 mm) 5.12 in (130 mm) CD-4LCA 5.99 oz (0.17 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) PZ-4LCA 3.10 oz (0.09 kg) 0.60 in (15 mm) 9.45 in (240 mm) 7.68 in (195 mm) CD-8LCA 6.46 oz (0.183 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) PZ-8LCE 3.70 oz (0.105 kg) 0.60 in (15 mm) 9.45 in (240 mm) 5.12 in (130 mm) CD-2BRIA 5.99 oz (0.17 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) PZ-2BRIA 4.02 oz (0.114 kg) 0.60 in (15 mm) 4.72 in (120 mm) 7.68 in (195 mm) CD-PRTA 5.5 oz (0.156 kg) 0.98 in (25 mm) 9.45 in (240 mm) 3.94 in (100 mm) CD-CCTA 5.5 oz (0.156 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) CD-4ODTA 8.25 oz (0.234 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) CD-RTB 12.17 oz (0.345 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.68 in (195 mm) CD-VM00 7.76 oz (0.22 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) CD-PVAA 10.05 oz (0.285 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.68 in (195 mm) CD-ETIA 12.17 oz (0.345 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.68 in (195 mm) CD-4DIOPB 7.73 oz (0.219 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) CHS BASE UNIT 21.87 oz (0.62 kg) 23.23 in (590 mm) 17.72 in (450 mm) 10.43 in (265 mm) CHS2U BLANK SLOT COVER KIT 1.76 oz (0.05 kg) 2.32 in (60 mm) 1.57 in (40 mm) 1.57 in (40 mm) Table 2-17 SV8100 Weights and Dimensions (Continued) Unit Shipping Weight 1 Height Width Depth

System Hardware Manual

2 - 29 CHS L BATT BOX RACK MOUNT BRACKET 352.7 oz (10 kg) 18.5 in (470 mm) 14.6 in (370 mm) 2.76 in (70 mm) CHS2U INT BATT SET 95.24 oz (2.7 kg) 4.33 in (110 mm) 2.76 in (70 mm) 3.15 in (80 mm) CHS2U RACK MOUNT KIT 17.6 oz (0.5 kg) 0.91 in (23 mm) 9.65 in (245 mm) 3.35 in (85 mm) CHS1U/2U WALL MOUNT KIT 35.27 oz (1 kg) 1.18 in (30 mm) 13.8 in (350 mm) 1.77 in (45 mm) CHS LARGE BATT BOX 458.6 oz (13 kg) 5.24 in (133 mm) 16.93 in (430 mm) 14.3 in (363 mm) CHS2U JOINT BRACKET KIT 7.06 oz (0.2 kg) 0.19 in (3 mm) 5.91 in (150 mm) 1.7 in (43 mm) CHS2U BATT MTG KIT 6 Slot 106 oz (3.0 kg) 2.95 in (75 mm) 4.45 in (113 mm) 4.13 in (105 mm) Digital Multiline Terminal DTL-2E-1 (BK) TEL 35.27 oz (1.0 kg) 4.41 in (112 mm) 7.05 in (179 mm) 8.86 in (225 mm) DTL-6DE-1 (BK) TEL 38.8 oz (1.1 kg) 4.41 in (112 mm) 7.05 in (179 mm) 8.86 in (225 mm) DTL-8LD-1 (BK) TEL DTL-8LD-1 (WH) TEL 45.6 oz (1.3 kg) 4.41 in (112 mm) 7.05 in (179 mm) 10.39 in (264 mm) DTL-12BT-1 (BK) TEL 45.6 oz (1.3 kg) 4.29 in (109 mm) 7.6 in (183 mm) 10.16 in (258 mm) DTL-12PA-1 (BK) TEL 45.6 oz (1.3 kg) 4.41 in (112 mm) 7.6 in (183 mm) 10.16 in (258 mm) DTL-12D-1 (BK) TEL DTL-12D-1 (WH) TEL 42.33 oz (1.2 kg) 4.39 in (111.7 mm) 7.05 in (179 mm) 10.16 in (258 mm) DTL-24D-1 (BK) TEL DTL-24D-1 (WH) TEL 42.33 oz (1.2 kg) 4.39 in (111.7 mm) 7.05 in (179 mm) 10.16 in (258 mm) DTL-32D-1 (BK) TEL DTL-32D-1 (WH) TEL 45.6 oz (1.3 kg 4.39 in (111.7 mm) 8.1 in (205.8 mm) 10.16 in (258 mm) IP Multiline Terminal ITL-2E-1 (BK) TEL 35.27 oz (1.0 kg) 4.41 in (112 mm) 7.05 in (179 mm) 8.86 in (225 mm) ITL-6DE-1 (BK) TEL 38.8 oz (1.1 kg) 4.41 in (112 mm) 7.05 in (179 mm) 8.86 in (225 mm) ITL-8LD-1 (BK) TEL ITL-8LD-1 (WH) TEL 45.6 oz (1.3 kg) 4.41 in (112 mm) 7.05 in (179 mm) 10.39 in (264 mm) Table 2-17 SV8100 Weights and Dimensions (Continued) Unit Shipping Weight 1 Height Width Depth

2 - 30

SV8100 System Specifications ITL-12BT-1 (BK) TEL 45.6 oz (1.3 kg) 4.29 in (109 mm) 7.59 in (193 mm) 10.16 in (258 mm) ITL-12D-1 (BK) TEL ITL-12D-1 (WH) TEL 42.33 oz (1.2 kg) 4.41 in (112 mm) 7.05 in (179 mm) 10.16 in (258 mm) ITL-12PA-1 (BK) TEL 45.6 oz (1.3 kg) 4.41 in (112 mm) 7.59 in (193 mm) 10.16 in (258 mm) ITL-24D-1 (BK) TEL ITL-24D-1 (WH) TEL 42.33 oz (1.2 kg) 4.41 in (112 mm) 7.05 in (179 mm) 10.16 in (258 mm) ITL-32D-1 (BK) TEL ITL-32D-1 (WH) TEL 45.6 oz (1.3 kg) 4.41 in (112 mm) 8.1 in (205.8 mm) 10.16 in (258 mm) ITL-320C-1 (BK) TEL 56.44 oz (1.6 kg) 4.41 in (112 mm) 8.94 in (227 mm) 9.84 in (250 mm) Optional 8LK-L (BK) UNIT 8LK-L (WH) UNIT 7.05 oz (0.2 kg) 1.77 in (45 mm) 1.15 in (29.3 mm) 8.82 in (224 mm) ADA-L UNIT 2.82 oz (0.08 kg) .98 in (25 mm) 2.56 in (65 mm) 3.23 in (82 mm) APR-L UNIT 5.29 oz (0.15 kg) 0.98 in (25 mm) 2.56 in (65 mm) 3.23 in (82 mm) BCH-L (BK) UNIT 5.29 ox (0.15 kg) 4.41 in (112 MM) 2.52 in (64 mm) 8.8 in (233 mm) BHA-L Unit 5.29 ox (0.15 kg) 0.98 in (25 mm) 2.56 in (65 mm) 2.84 in (72 mm) IPLA-R UNIT 2.82 oz (0.08 kg) 0.98 in (25 mm) 2.24 in (57 mm) 3.94 in (100 mm) PGD(2)-U10 ADP 12.4 oz (0.35 kg) 1.58 in (40 mm) 6.81 in (173 mm) 4.13 in (105 mm) DCL-60-1 (BK) CONSOLE DCL-60-1 (WH) CONSOLE 21.16 oz (.6 kg) 3.23 in (82 mm) 5.39 in (137 mm) 8.82 in (224 mm) PSA-L (BK) UNIT PSA-L (WH) UNIT 10.58 oz (0.3 kg) 3.15 in (80 mm) 2.91 in (74 mm) 8.8 in (223 mm) WM-L UNIT 1.58 oz (0.045 kg) 0.996 in (25.3 mm) 3.996 in (101.5 mm) 4.92 in (125 mm) 1 Shipping weight includes the shipping carton. Table 2-17 SV8100 Weights and Dimensions (Continued) Unit Shipping Weight 1 Height Width Depth

System Hardware Manual

3 - 1 Chapter 3 Installing the SV8100 Chassis SECTION 1 GENERAL INFORMATION This chapter contains information to help the technician install the chassis for the SV8100 system. The technician should be familiar with this section before installing any equipment. SECTION 2 INSTALLING THE CHASSIS The CHS2U-EU chassis has six universal blade slots for legacy line/trunk blade (Single Line Telephone Interface, Digital Multiline Terminal Interface, Central Office Trunk, ISDN PRI Interface, etc.), In-skin Application Blades (In-skin UMS, In-Skin Router, etc.). It also houses the BUS Interface Blade, Power Supply Unit (PSU) and Cooling FAN. When the CD-CP00 blade is installed in the first 19” chassis, it is referred to as the controlling chassis. Additional chassis, referred to as expansion chassis, can be installed to increase the capacity of the system to meet the customer’s business needs. Each chassis (Expansion or Controlling), is powered by a MPS7101 power supply. The chassis can be wall mounted, floor mounted, stand mounted or rack mounted. The first part of the this chapter describes the differing types of mounting options and the rest of this section describes how to install the chassis.

3 - 2

Installing the SV8100 Chassis 2.1 Wall Mounting the 19” Chassis When wall mounting the chassis, ensure the wall can support the weight of the chassis (55 lbs per system chassis ---- including blades, cords, power supply, etc.). The chassis is secured to the wall with a wall mount bracket. Ensure that enough space is available to allow the installation of additional expansion chassis. Figure 3-1 CHS2U Chassis (Front View) Figure 3-2 CHS2U Chassis (Rear View) Universal Slot for Legacy Line/Trunk blades and Application blades (six slots). When using as controlling chassis, the CD-CP00 is mounted in Slot 1 (shown). Slot for PZ-BS10/PZ-BS11 blade – Connection with CHS2U chassis Power Supply Unit (PSU) Fan Unit (inside of cover) Internal Battery Mount Battery Connector (inside of cover) AC Connector Frame Ground (FG) Terminal

System Hardware Manual

3 - 3 2.1.1 CHS2U Chassis Wall Mount Installation 1. Use the template shown in Figure 3-3 Wall Mount Spacing Guide (19” Chassis) on page 3-3 for required spacing before drilling. 2. Mark and drill the six holes required for a wall installation. 3. Align screw holes in wall mount brackets with drilled holes. Figure 3-3 Wall Mount Spacing Guide (19” Chassis) Upper Surface of Wall Mount Bracket

3 - 4

Installing the SV8100 Chassis 4. Using six screws, secure the two wall mount brackets to the wall. Refer to Figure 3-4 Install Wall Mount Brackets with Screws for screw location. 5. Using four screws, secure the metal fittings on the Left and Right sides of the 19” chassis. Refer to Figure 3-5 Install Wall Mount Brackets with Screws on page 3-5 for screw location. Figure 3-4 Install Wall Mount Brackets with Screws

System Hardware Manual

3 - 5 Figure 3-5 Install Wall Mount Brackets with Screws

3 - 6

Installing the SV8100 Chassis 6. Align the metal fitting with the upper wall mount bracket. The lower metal fitting will rest against the lower wall mount bracket. Secure the metal fitting and upper wall mount bracket with a single screw (see Figure 3-6 Secure Metal Fitting to Upper Wall Mount Bracket with a Screw). 7. Using two screws, secure the metal fitting to the lower wall mount bracket. Refer to Figure 3-7 Secure Metal Fitting to Lower Wall Mount Bracket with Screws on page 3-7 for screw location. Figure 3-6 Secure Metal Fitting to Upper Wall Mount Bracket with a Screw

System Hardware Manual

3 - 7 8. Attach the supplied cable support bracket to either end of the lower wall mount bracket with a single screw (refer to Figure 3-8 Attach Cable Support Bracket with Screw on page 3-8). Figure 3-7 Secure Metal Fitting to Lower Wall Mount Bracket with Screws

3 - 8

Installing the SV8100 Chassis 9. The cable support bracket can be installed any of the four corners of the 19” chassis (refer to Figure 3-9 Attach Cable Support Bracket with Screw on page 3-9). Figure 3-8 Attach Cable Support Bracket with Screw

System Hardware Manual

3 - 9 10. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-34 for complete details on grounding the system. 11. Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue installation of the chassis or, Chapter 5 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. Figure 3-9 Attach Cable Support Bracket with Screw

3 - 10

Installing the SV8100 Chassis 2.2 Floor Mounting the 19” Chassis The CHS2U controlling and expansion chassis can be mounted on the floor using the CHS BASE UNIT and the CHS2U JOINT BRACKET KIT. 2.2.1 CHS2U Chassis Installation 1. Use the template shown in Figure 3-10 Floor Mount Spacing Guide for required spacing before drilling holes for 0.39” (10mm) anchor bolts (locally procured). 2. Mark and drill the four holes required for installing the CHS BASE UNIT. 3. Using anchor bolts, secure the CHS BASE UNIT to the floor. Refer to Figure 3-11 Secure CHS BASE UNIT with Anchor Bolts on page 3-11 for screw location. Figure 3-10 Floor Mount Spacing Guide

System Hardware Manual

3 - 11 . 4. Install the five rubber feet to the bottom of the chassis. 5. Position the chassis on top of the CHS BASE UNIT. 6. Secure the chassis to the CHS BASE UNIT using eight screws supplied with the CHS2U JOINT BRACKET KIT. Figure 3-11 Secure CHS BASE UNIT with Anchor Bolts Figure 3-12 Install Rubber Feet

3 - 12

Installing the SV8100 Chassis 7. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-34 for complete details on grounding the system. 8. Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue installation of the chassis or, Chapter 5 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. 2.2.2 Multiple CHS2U Chassis Installation Expansion chassis can be secured to the CHS BASE UNIT and will require an additional CHS2U JOINT BRACKET KIT per chassis. Figure 3-13 Install CHS2U JOINT BRACKET KIT

System Hardware Manual

3 - 13 1. Install the five rubber feet to the bottom of each chassis. 2. Using supplied screws in the CHS2U JOINT BRACKET KIT, attach metal brackets to both ends of the 19” chassis and the CHS BASE UNIT. Refer to Figure 3-15 Install Metal Brackets with Screws. Figure 3-14 Install Rubber Feet Figure 3-15 Install Metal Brackets with Screws Metal Brackets

3 - 14

Installing the SV8100 Chassis 3. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-34 for complete details on grounding the system. 4. Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue installation of the chassis or, Chapter 5 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. 2.3 Stand Mounting the 19” Chassis A single or multiple chassis can be stand mounted. Controlling and Expansion chassis can be stand mounted using the CHS2U STAND KIT(K) and CHS2U STAND KIT (EXT). 2.3.1 CHS2U Chassis Installation 1. Using the supplied screws, assemble the CHS2U STAND KIT(K) and CHS2U STAND KIT (EXT) (refer to Figure 3-16 Assemble Stand Mount with Screws). 2. Secure the CHS2U chassis to the assembled CHS2U STAND KIT, see Figure 3-17 Secure CHS2U Chassis to CHS2U STAND KIT with Screws on page 3-15. Figure 3-16 Assemble Stand Mount with Screws Expansion Plate

System Hardware Manual

3 - 15 3. Using supplied screws, secure the CHS2U STAND KIT to the floor (refer to Figure 3-18 Secure Stand Mount to Floor with Screws on page 3-16). Figure 3-17 Secure CHS2U Chassis to CHS2U STAND KIT with Screws Expansion Plate

3 - 16

Installing the SV8100 Chassis 4. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-34 for complete details on grounding the system. 5. Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue installation of the chassis or, Chapter 5 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. Figure 3-18 Secure Stand Mount to Floor with Screws

System Hardware Manual

3 - 17 2.3.2 Multiple CHS2U Chassis Installation Expansion chassis (maximum of three) can be added to the CHS2U STAND KIT and will require an additional CHS2U STAND KIT (EXT) per chassis. 1. Install the five rubber feet to the bottom of each chassis. 2. Each additional chassis will require CHS2U STAND KIT (EXT) to be installed (refer to Figure 3-20 Install Additional CHS2U STAND KIT (EXT) on page 3-18). Figure 3-19 Attach Rubber Feet to CHS2U Chassis

3 - 18

Installing the SV8100 Chassis 3. Metal brackets from the CHS2U JOINT BRACKET KITs will be required to secure the top end of the chassis with screws. See Figure 3-21 Install Additional CHS2U STAND KIT (EXT) on page 3-19. Figure 3-20 Install Additional CHS2U STAND KIT (EXT) Expansion Plates

System Hardware Manual

3 - 19 4. Using supplied screws, secure the CHS2U STAND KIT to the floor (refer to Figure 3-21 Install Additional CHS2U STAND KIT (EXT) on page 3-19). 5. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-34 for complete details on grounding the system. 6. Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue installation of the chassis or, Chapter 5 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. Figure 3-21 Install Additional CHS2U STAND KIT (EXT) Metal Brackets

3 - 20

Installing the SV8100 Chassis 2.4 Rack Mounting the 19” Chassis A single or multiple chassis can be rack mounted. Controlling and Expansion chassis can be racked mounted by stacking them horizontally. 1. The 19” chassis requires two rack mount brackets per chassis for mounting. Refer to Figure 3-22 CHS2U Rack Mount Brackets. 2. Line up the Rack Mount Bracket(s) with the pre-drilled holes on each side of the 19” chassis. 3. Secure the brackets to the chassis using the supplied screws. Refer to Figure 3-23 Rack Mount Bracket Installed 19” CHS2U on page 3-21 for the 19” chassis. Figure 3-22 CHS2U Rack Mount Brackets

System Hardware Manual

3 - 21 Repeat for additional chassis mounting. 4. Carefully slide the chassis into desired location within the rack. Make sure the hooks on the mounting bracket are inserted into the back of the chassis, securing it in place. Note that the cabling is run through the front of the rack for ease of access. 5. Secure the brackets to the rack using the screws supplied. Repeat for additional chassis mounting. Figure 3-23 Rack Mount Bracket Installed 19” CHS2U Figure 3-24 Rack Mount 19” CHS2U Each CHS2U chassis will require approximately 3.5” of height within the rack. Single CHS2U Rack Mount Single CHS2U Rack Mount with Three Expansion Chassis

3 - 22

Installing the SV8100 Chassis 6. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-34 for complete details on grounding the system. 7. Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue installation of the chassis or, Chapter 5 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. 2.5 Installing the 19” Chassis There are two types of chassis; the controlling (with the CD-CP00 installed) and the expansion (that does not have the CCPU blade installed). As discussed in other chapters, multiple chassis can be linked together to expand the port size of the system. 2.5.1 Unpacking the Equipment Inspect the equipment for any physical damage. If you are not sure about the function of a component, review the associated information within this manual. Contact your authorized NEC Sales Representative if you have additional questions. Note that the chassis does not initially contain any blades. Make sure you have appropriate tools for the job, including: a test set, a punch down tool, and a digital voltmeter. Ensure that you have a building plan showing common equipment, extensions, the Telco demarcation and earth ground location before you start installation. Be sure to properly plan your installation site and that you are familiar with the installation safety precautions. If you have not done that, please do so now. 2.5.2 Before Installation Before installing the chassis check the following: � Ensure that the MPS7101(Power Supply Unit) is OFF and that that the power cord is disconnected from the AC outlet. � When installing the blades, do not touch the soldered surfaces as this may cause damage.

System Hardware Manual

3 - 23 2.5.3 Installing the 19” Controlling Chassis 1. Ensure the chassis is powered down. 2. Align the CD-CP00 blade with the Slot 1 guides of the Controlling Chassis. 3. Slide the CD-CP00 blade into the chassis until resistance (back plane) is felt. Figure 3-25 19” Controlling Chassis – Guides Slot 1 Figure 3-26 Installing the CD-CP00 Blade Do not remove or install this blade with the power on.

3 - 24

Installing the SV8100 Chassis 4. Gently push until the blade seats. Tighten the two retaining screws on front of the blade. 2.5.4 Installing Expansion Blades in the 19” Chassis (Optional) When adding additional chassis to the system to expand the capacity, a PZ-BS10 must be installed in the Controlling Chassis and a PZ-BS11 must be installed in all Expansion Chassis. This connection is required with any multiple-chassis setup. The PZ-BS10 connects the Controlling Chassis to the Expansion Chassis by connecting to a PZ-BS11, which is installed on each Expansion Chassis. These Expansion Interface Units allow the CPU to transmit/receive data as required to the additional chassis. The PZ-BS10 is installed in the EXIFU slot of the Controlling Chassis which is equipped with a CPU card. The PZ-BS11 is installed in the expansion slot of the Expansion Chassis, which does not have a CPU. The EXIFU cable connects the Controlling Chassis and its EXIFU-B1 interface to the second, third, and fourth EXIFU-E1 interface. Use only the CAT 5 cables provided by NEC to make the connections between the Controlling and Expansion Chassis. The PZ-BS10 provides: � Communication Processor Interface for data handling through Communication Channel (24 slots maximum) � 32 Channels for Telephony Resource (e.g., DTMF Tone Receiver, Call Progress Tone Detector, MFC Tone Receiver, Caller ID Receiver, Caller ID Signal Sender) � DSP Resource Management Figure 3-27 CD-CP00 Blade Installed

System Hardware Manual

3 - 25 2.5.4.1 Connector Pin-Out on the PZ-BS10/PZ-BS11 2.5.4.2 Install the PZ-BS10 Expansion Base Blade in the CHS2U Controlling Chassis 1. Ensure the chassis is powered down. 2. Locate the door positioned on the left end (expansion bay) of the Controlling Chassis. Table 3-1 PZ-BS10/PZ-BS11 Connector Pin-Out RJ-61 Cable Connector PZ-BS10 – CN2, CN3, CN 4 PZ-BS11 – CN3 Pin No. Connection 1 HW_UP (+) 2 HW_UP (-) 3 HW_DWN (+) 4 FS (+) 5 FS (-) 6 HW_DWN (-) 7 CK8M (+) 8 CK8M (-) Figure 3-28 PZ-BS10 Expansion Bay in Controlling Chassis Do not remove or install this blade with the power on. Expansion Bay

3 - 26

Installing the SV8100 Chassis 3. From the left side of the chassis, pull cover outward to expose the expansion bay. 4. Pull the cover toward you to remove. . Cover must be removed prior to installation of PZ-BS10 blade. 5. Align the PZ-BS10 blade with the guides located in the expansion bay. Figure 3-29 Open Base Chassis Cover Figure 3-30 PZ-BS10 Blade Guides

System Hardware Manual

3 - 27 6. Slide the PZ-BS10 blade into the chassis until resistance (back plane) is felt. 7. Gently push until the blade seats and install the supplied retaining screw. Figure 3-31 PZ-BS10 Components Figure 3-32 Installing PZ-BS10 Blade in Expansion Bay

3 - 28

Installing the SV8100 Chassis 8. Align the door tabs with hinges and reattach the cover. 9. Close the PZ-BS10 cover. 2.5.4.3 Install the PZ-BS11 Expansion Blade in the CHS2U Expansion Chassis . For the Expansion Chassis to function, the PZ-BS10 blade must be installed in Controlling Chassis. 1. Ensure the chassis is powered down. Figure 3-33 PZ-BS10 Blade Installed Figure 3-34 PZ-BS10 Installed (Cover Closed) Do not remove or install this blade with the power on.

System Hardware Manual

3 - 29 2. Locate the door positioned on the left end (expansion bay) of the Expansion Chassis. 3. From the left side of the chassis, pull cover outward to expose the expansion bay. Figure 3-35 PZ-BS11 Expansion Bay in Expansion Chassis Figure 3-36 Open Expansion Chassis Cover Expansion Bay

3 - 30

Installing the SV8100 Chassis 4. Pull the cover toward you to remove. . Cover must be removed to install PZ-BS11 blade. 5. Align the PZ-BS11 blade with the guides located within the expansion bay. 6. Slide the PZ-BS11 blade into the chassis until resistance (back plane) is felt. 7. Gently push until the blade seats and install the supplied retaining screw. Figure 3-37 PZ-BS11 Blade Guides Figure 3-38 Installing PZ-BS11 Blade in Expansion Chassis

System Hardware Manual

3 - 31 8. Align the door tabs with hinges and reattach the cover. 9. Close the PZ-BS11 blade cover. Figure 3-39 PZ-BS11 Blade Installed Figure 3-40 PZ-BS11 Installed (Cover Closed)

3 - 32

Installing the SV8100 Chassis 2.5.4.4 Connect the Controlling and Expansion Chassis . Installment of the PZ-BS10 blade and PZ-BS11 blade(s) must be completed prior to installation of the provided (Cat 5) expansion cabling. 1. Ensure Controlling and Expansion chassis are powered down. 2. Using the NEC provided CAT5 straight-through cable(s), attach one end to each Expansion Chassis CN2 connector on the PZ-BS11 blade (see Figure 3-42 System Expansion Cabling on page 3-33. Attach the opposite end to the CN2, CN3 or CN4 connector on the PZ-BS10 of the Controlling Chassis. Figure 3-41 19” Expansion Chassis Interface Units Expansion Chassis Interface Unit for the Controlling Chassis PZ-BS10 Expansion Chassis Interface Unit for the Expansion Chassis PZ-BS11

System Hardware Manual

3 - 33 3. Repeat for additional Expansion Chassis. Figure 3-42 System Expansion Cabling Install in Controlling Chassis Install in Expansion Chassis Install in Expansion Chassis Install in Expansion Chassis

3 - 34

Installing the SV8100 Chassis 2.5.5 Install 19” Chassis Grounding From the factory, the SG, ETH and PBXG grounds are located inside the chassis and are connected to the FG ground (frame ground) on the back of the chassis. Each chassis (CHS2U) in the system must be grounded separately using the procedure listed below. 1. Ensure each Chassis is powered down and unplugged. 2. Ground each chassis by connecting a 14 AWG wire from the FG lug on the back side of the chassis to an electrical service ground (such as a cold water pipe). 2.5.6 Install 19” Grounding on Multiple Chassis (Optional) From the factory, the SG, ETH and PBXG grounds are located inside the chassis and are connected to the FG ground (frame ground) on the back of the chassis. Each chassis (CHS2U) in the system must be grounded separately using the procedure listed below. 1. Ensure all Controlling and Expansion Chassis are powered down and unplugged. 2. Ground each chassis by connecting a 14 AWG wire from the FG lug on the back side of the chassis to an electrical service ground (such as a cold water pipe). Figure 3-43 Chassis Grounding Lug FG Lug CHS2U

System Hardware Manual

3 - 35 2.5.7 Install AC Power Cords 1. Locate the supplied AC power cord and attach to the AC Inlet located on the back of the Controlling Chassis. Figure 3-44 19” Chassis Grounding Lug (Multiple-Chassis) Figure 3-45 Install the AC Power Cord FG Lugs Electrical Service Ground AC Inlet CHS2U

3 - 36

Installing the SV8100 Chassis 2.5.8 Install AC Power Cords on Multiple-Chassis (Optional) 1. Locate the supplied AC power cords and attach to the AC Inlets located on the back of the Controlling and Expansion Chassis. 2.5.9 Install Additional Blades Refer to Chapter 5, 2.1 Installation and Safety Precautions on page 4-3. 2.5.10 Apply Power to the 19” Chassis Refer to Chapter 5, 2.6 Powering Up the SV8100 on page 4-8. Figure 3-46 Install 19” AC Power Cords (Multiple-Chassis) AC Power Cords to AC Inlets

System Hardware Manual

3 - 37 SECTION 3 BATTERY CONNECTION There are two types of battery connection to provide battery life in the event of a power failure, the internal battery and an external battery with CHS LARGE BATT BOX. 3.1 Installing the Internal Batteries An internal battery source using two batteries can be installed using the CHS2U BATT MTG KIT (mounting kit) and CHS2U BATT CABLE INT (internal cabling). CHS2U BATT MTG KIT (Backup time = 10 Minutes/24 Terminals) 1. Ensure the chassis is powered down. 2. Disconnect AC power and grounding cable from rear of chassis. 3. Remove screws from battery access panel on rear of chassis. Refer to Figure 3-47 Removing Battery Access Panel. Figure 3-47 Removing Battery Access Panel Ensure the CHS2U chassis is powered OFF.

3 - 38

Installing the SV8100 Chassis 4. Remove access panel containing the fan. Refer to Figure 3-48 Removing Access Panel and Figure 3-49 Access Panel Removed. Figure 3-48 Removing Access Panel Figure 3-49 Access Panel Removed

System Hardware Manual

3 - 39 5. Using tie wraps, secure CHS2U BATT CABLE INT in cable guide bracket (refer to Figure 3-50 Installing Cable Guide). 6. With supplied screw, install cable guide in chassis (refer to Figure 3-51 Installing Cable Guide). Figure 3-50 Installing Cable Guide Figure 3-51 Installing Cable Guide

3 - 40

Installing the SV8100 Chassis 7. Install two 2.3 AH-12V batteries (locally procured) into the CHS2U BATT MTG KIT (refer to Figure 3-52 Installing Two Batteries). . The first battery must be installed on the left side, then slid to the right due to an installation tab on the mounting kit. 8. Using the supplied screws, secure the brackets to the CHS2U BATT MTG KIT (refer to Figure 3-52 Installing Two Batteries on page 3-40). Figure 3-52 Installing Two Batteries

Other Telephone System Manuals