NEC SV-8100 System Hardware Manual

Text of the manual

Nothing contained in this manual shall be deemed to be, and this manual does not constitute, a

warranty of, or representation with respect to, any of the equipment covered. This manual is subject to change without notice and NEC Infrontia has no obligation to provide any updates or corrections to this manual. Further, NEC Infrontia also reserves the right, without prior notice, to make changes in equipment design or components as it deems appropriate. No representation is made that this manual is complete or accurate in all respects and NEC Infrontia shall not be liable for any errors or omissions. In no event shall NEC Infrontia be liable for any incidental or consequential damages in connection with the use of this manual. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied or reproduced without prior written consent of NEC Infrontia. ©2008 by NEC Infrontia Corporation All Rights Reserved. Printed in Japan CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Chapter 1; Introduction to SV8100

SECTION 1 GENERAL INFORMATION.........................................................................1-1 SECTION 2 EQUIPMENT LIST.....................................................................................1-5 Chapter 2; SV8100 System Specifications SECTION 1 GENERAL INFORMATION.........................................................................2-1 SECTION 2 SYSTEM BLOCK DIAGRAM .....................................................................2-1 SECTION 3 MAXIMUM SYSTEM CAPACITIES.............................................................2-5 3.1 SYSTEM CONFIGULATION - SV8100..................................................................2-6 SECTION 4 POWER- BASED CALCULATOR CHART...........................................2-11 SECTION 5 SYSTEM REQUIREMENT AND SPECIFICATION .................................2-14 5.1 CABLING........................................................................................................2-14 5.2 POWER REQUIREMENTS.................................................................................2-17 5.2.1 POWER SUPPLY SPECIFICATION ..........................................................2-17 5.2.2 POWER SUPPLY CONSUMPTION ...........................................................2-18 5.3 ENVIRONMENTAL CONDITIONS ........................................................................2-18 5.3.1 TEMPERATURE AND HUMIDITY .............................................................2-18 5.4 OUTSIDE LINE TYPE .......................................................................................2-19 5.5 TRANSMISSION, NETWORK AND CONTROL SPECIFICATIONS..............................2-20 5.5.1 TRANSMISSION ..................................................................................2-20 5.5.2 NETWORK ..........................................................................................2-20 5.5.3 CONTROL ..........................................................................................2-20 5.6 DIALING SPECIFICATIONS................................................................................2-21 5.6.1 DIAL PULSE ADDRESS SIGNALING ........................................................2-21 5.6.2 DUAL TONE MULTIFREQUENCY(DTMF) ADDRESS SIGNALING ................2-21 5.6.3 EXTERNAL EQUIPMENT CONNECTION ...................................................2-22 5.6.4 MUSIC SOURCE FOR MUSIC ON HOLD VIA CHASSIS ...............................2-22 5.6.5 MUSIC SOURCE FOR STATION BACKGROUND MUSIC VIA ACI..................2-22 5.6.6 EXTERNAL PAGING (AUDIO) .................................................................2-22 5.6.7 EXTERNAL TONE RINGER/NIGHT CHIME OUTPUT ..................................2-22 5.6.8 SMDR................................................................................................2-22 5.6.9 PC CONNECTION ................................................................................2-22 5.6.10 RELAY CONNECTION............................................................................2-22 5.7 BATTERY BACKUP ..........................................................................................2-23 5.7.1 SYSTEM BACKUP(OPTIONAL) ...............................................................2-23 5.7.2 MEMORY BACKUP................................................................................2-23 5.8 WEIGHT AND DIMENSIONS ..............................................................................2-24 System Hardware Manual I CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Chapter 3; Installing the SV8100 Chassis

SECTION 1 GENERAL INFORMATION..................................................................3-1 SECTION 2 INSTALLING THE CHASSIS...............................................................3-1 2.1 WALL MOUNT THE 19” CHASSIS........................................................................3-2 2.1.1 CHS2U CHASSIS WALL MOUNT INSTALLATION........................................3-3 2.2 FLOOR MOUNTING THE 19” CHASSIS...............................................................3-10 2.2.1 CHS2U CHASSIS INFORMATION...........................................................3-10 2.2.2 MULTIPLE CHS2U CHASSIS INSTALLATION ...........................................3-12 2.3 STAND MOUNTING THE 19” CHASSIS...............................................................3-14 2.3.1 CHS2U CHASSIS INFORMATION...........................................................3-14 2.3.2 MULTIPLE CHS2U CHASSIS INSTALLATION ...........................................3-16 2.4 RACK MOUNTING THE 19” CHASSIS.................................................................3-19 2.5 INSTALLING THE 19” CHASSIS .........................................................................3-21 2.5.1 UNPACKING THE EQUIPMENT................................................................3-21 2.5.2 BEFORE INSTALLATION.........................................................................3-21 2.5.3 INSTALLING THE 19” CONTROLLING CHASSIS.........................................3-22 2.5.4 INSTALLING EXPANSION BLADE IN THE 19” CHASSIS (OPTIONAL) ..........3-23 2.5.4.1 CONNECTOR PIN-OUT ON THE PZ-BS10/PZ-BS11....................3-24 2.5.4.2 INSTALL THE PZ-BS10 EXPANSION BASE BLADE IN THE CHS2U CONTROLLING CHASSIS ..........................................................3-24 2.5.4.3 INSTALL THE PZ-BS11 EXPANSION BLADE IN THE CHS2U EXPANSION CHASSIS................................................................3-27 2.5.4.4 CONNECT THE CONTROLLING AND EXPANSION CHASSIS .............3-31 2.5.5 INSTALLING 19” CHASSIS GROUNDING..................................................3-33 2.5.6 INSTALLING 19” CHASSIS GROUNDING ON MULTIPLE CHASSIS (OPTIONAL).........................................................................................3-33 2.5.7 INSTALL AC POWER CORDS.................................................................3-34 2.5.8 INSTALL AC POWER CORDS ON MULTIPLE-CHASSIS (OPTIONAL)............3-35 2.5.9 INSTALL ADDITIONAL BLADES................................................................3-35 2.5.10 APPLY POWER TO THE 19” CHASSIS ...................................................3-35 SECTION 3 BATTERY CONNECTION.................................................................3-36 3.1 INSTALLING THE INTERNAL BATTERIES .............................................................3-36 3.2 INSTALLING THE EXTERNAL BATTERIES............................................................3-42 3.2.1 FLOOR MOUNTING THE CHS LARGE BATT BOX ................................3-42 3.2.2 BATTERY INSTALLATION........................................................................3-44 3.2.3 CHS LARGE BATT BOX TO CHS2U CONNECTION.............................3-48 3.2.4 CHS LARGE BATT BOX FUSE REPLACEMENT ...................................3-51 SECTION 4 REMOVE AND INSTALL COOLING FAN ............................................3-55 II CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

4.1 CHS2U CHASSIS...........................................................................................3-55

4.1.1 REMOVE COOLING FUN .......................................................................3-55 4.1.2 INSTALL COOLING FUN.........................................................................3-57 Chapter 4; Installing the SV8100 Blades SECTION 1 GENERAL INFORMATION..................................................................4-1 1.1 SLOT LOCATIONS .............................................................................................4-1 SECTION 2 INSTALLATION.................................................................................4-3 2.1 INSTALLATION AND SAFETY PRECAUTIONS .........................................................4-3 2.2 INSTALLING AN EXTENSION OR TRUNK BLADE ....................................................4-4 2.2.1 INSTALLING THE BLADE ..........................................................................4-4 2.2.2 ORDER OF INSTALLING EXTENSION BLADES ............................................4-4 2.2.3 ORDER OF INSTALLING TRUNK BLADES ...................................................4-5 2.2.3.1 INSTALLING CD-4COTA, CD-4DIOPB, CD-4ODTB OR CD-2BRIA BLADES....................................................................4-5 2.2.3.2 INSTALLING CD-PRTA (T1/E1/PRI) BLADES................................4-5 2.3 REMOVE AN EXTENSION OR TRUNK BLADE........................................................4-6 2.4 UNINSTALLING A BLADE SLOT THROUGH SOFTWARE ..........................................4-6 2.5 BLADE CAPACITIES...........................................................................................4-6 2.6 POWERING UP THE SV8100.............................................................................4-8 2.6.1 PERFORMING A COLD START..................................................................4-8 2.6.2 PERFORMING A HOT START....................................................................4-9 2.6.3 RESETING THE SYSTEM .........................................................................4-9 2.6.3.1 INITIAL PROGRAMMING................................................................4-9 2.6.3.2 PORT DEFAULTS .......................................................................4-10 2.6.3.3 SETTING UP EXTENSION CIRCUIT TYPES....................................4-10 2.6.3.4 SAVING YOUR CONFIGURATION ................................................. 4-11 2.6.3.5 BACKING UP/RESTORING A DATABASE ....................................... 4-11 2.6.4 PERFORMING A SOFTWARE UPGRADE...................................................4-12 SECTION 3 COMMON CONTROL BLADE...........................................................4-14 3.1 CD-CP00 (SV8100 CENTRAL PROCESSING UNIT)..........................................4-14 3.1.1 DESCRIPTION......................................................................................4-15 3.1.2 INSTALLATION......................................................................................4-17 3.1.3 SWITCH SETTINGS...............................................................................4-19 3.1.4 LED INDICATION..................................................................................4-20 3.1.5 CONNECTORS .....................................................................................4-22 3.2 PZ-ME50 (MEMORY EXPANSION DAUGHTER BOARD)......................................4-24 System Hardware Manual II CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

3.3 PZ-VM21 (VOICE MAIL DAUGHTER BOARD)....................................................4-27

3.3.1 DESCRIPTION......................................................................................4-27 3.3.2 INSTALLATION......................................................................................4-28 3.3.3 SWITCH SETTINGS...............................................................................4-29 3.4 PZ-32IPLA/PZ-64IPLA/PZ-128IPLA (VOICE OVER IP DAUGHTER BOARDS)...4-30 3.4.1 DESCRIPTION......................................................................................4-30 3.4.2 INSTALLATION......................................................................................4-31 3.4.3 SWITCH SETTINGS...............................................................................4-31 3.4.4 LED INDICATIONS................................................................................4-32 3.4.5 CONNECTORS .....................................................................................4-33 SECTION 4 STATION BLADES..........................................................................4-35 4.1 CD-8DLCA/CD-16DLCA (DIGITAL STATION INTERFACE) ...............................4-35 4.1.1 DESCRIPTION......................................................................................4-36 4.1.2 INSTALLATION......................................................................................4-37 4.1.3 LED INDICATIONS................................................................................4-37 4.1.4 CONNECTORS .....................................................................................4-38 4.2 PZ-8DLCB (DIGITAL STATION DAUGHTER BOARD) .........................................4-40 4.2.1 DESCRIPTION......................................................................................4-40 4.2.2 INSTALLATION......................................................................................4-41 4.2.3 PZ-8DLCB DAUGHTER BOARD CABLE CONNECTION............................4-41 4.3 CD-4LCA/ CD-8LCA (4-PORT/8-PORT SINGLE LINE INTERFACE) ...................4-42 4.3.1 DESCRIPTION......................................................................................4-43 4.3.2 INSTALLATION......................................................................................4-44 4.3.3 LED INDICATIONS................................................................................4-45 4.3.4 CONNECTORS .....................................................................................4-46 4.4 PZ-4LCA/PZ-8LCE (4-PORT/8-PORT SLT DAUGHTER BOARDS)....................4-47 4.4.1 DESCRIPTION......................................................................................4-49 4.4.2 INSTALLATION......................................................................................4-50 4.4.3 CONNECTORS .....................................................................................4-51 4.5 CD-LTA (DTERM/SLT COMBINATION) ............................................................4-52 4.5.1 DESCRIPTION......................................................................................4-52 4.5.2 INSTALLATION......................................................................................4-53 4.5.3 LED INDICATIONS................................................................................4-54 4.5.4 CONNECTORS .....................................................................................4-55 SECTION 5 TRUNK BLADES............................................................................4-56 IV CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

5.1 CD-4COTA (4 LOOP START INTERFACE)........................................................4-56

5.1.1 DESCRIPTION......................................................................................4-56 5.1.2 INSTALLATION......................................................................................4-58 5.1.3 LED INDICATIONS................................................................................4-58 5.1.4 CONNECTORS .....................................................................................4-59 5.2 PZ-4COTE (4 LOOP START INTERFACE DAUGHTER BOARD) ...........................4-60 5.2.1 DESCRIPTION......................................................................................4-60 5.2.2 INSTALLATION......................................................................................4-62 5.2.3 CONNECTORS .....................................................................................4-62 5.3 CD-2BRIA (2 BASIC RATE INTERFACE) ..........................................................4-63 5.3.1 DESCRIPTION......................................................................................4-63 5.3.2 INSTALLATION......................................................................................4-64 5.3.3 LED INDICATIONS................................................................................4-65 5.3.4 CONNECTORS .....................................................................................4-66 5.4 PZ-2BRIA (2 BASIC RATE INTERFACE DAUGHTER BOARD)..............................4-67 5.4.1 DESCRIPTION......................................................................................4-68 5.4.2 INSTALLATION......................................................................................4-69 5.4.3 CONNECTORS .....................................................................................4-70 5.5 CD-4DIOPB (DID/OPX INTERFACE)..............................................................4-71 5.5.1 DESCRIPTION......................................................................................4-71 5.5.2 INSTALLATION......................................................................................4-72 5.5.3 LED INDICATIONS................................................................................4-72 5.5.4 CONNECTORS .....................................................................................4-73 5.6 CD-PRTA (PRI/T1/E1 INTERFACE)............................................................4-74 5.6.1 DESCRIPTION......................................................................................4-74 5.6.2 INSTALLATION......................................................................................4-75 5.6.3 LED INDICATIONS................................................................................4-77 5.6.4 CONNECTORS .....................................................................................4-79 5.7 CD-4ODTB (4-PORT TIE LINE INTERFACE BLADE)..........................................4-81 5.7.1 DESCRIPTION......................................................................................4-81 5.7.2 INSTALLATION......................................................................................4-82 5.7.3 LED INDICATIONS................................................................................4-83 5.7.4 CONNECTORS .....................................................................................4-84 5.7.5 CONNECTIONS ....................................................................................4-85 SECTION 6 OPTIONAL BLADES.......................................................................4-87 6.1 CD-VM00 (VOICE MAIL AND SERVER)............................................................4-87 6.1.1 DESCRIPTION......................................................................................4-87 System Hardware Manual V CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

6.1.3 LED INDICATIONS................................................................................4-89

6.1.3.1 ACTIVE LED - GREEN ..............................................................4-89 6.1.3.2 BUSY LED - RED......................................................................4-90 6.1.3.3 APPLICATION LED - RED/GREEN (DUAL COLOR) ......................4-90 6.1.3.4 COMPACTFLASH CARD ACTIVITY LED - RED ............................4-90 6.1.4 CONNECTORS .....................................................................................4-90 6.1.4.1 RS-232 INTERFACE .................................................................4-90 6.1.4.2 DB9 TO 6-PIN MODULAR RS-232 ADAPTER...............................4-91 6.1.4.3 RS-232 SERIAL CABLE (DTE)...................................................4-91 6.1.4.4 RS-232 SERIAL CABLE (DCE) ..................................................4-92 6.1.4.5 USB INTERFACE.......................................................................4-92 6.1.4.6 VGA DISPLAY INTERFACE .........................................................4-92 6.1.4.7 10 BASE-T/100 BASE-TX ETHERNET INTERFACE .....................4-92 6.2 CD-PVAA (CONFERENCE BRIDGE) ................................................................4-94 6.2.1 DESCRIPTION......................................................................................4-94 6.2.2 INSTALLATION......................................................................................4-95 6.2.3 SWITCH SETTINGS...............................................................................4-95 6.2.4 LED INDICATIONS................................................................................4-96 6.2.5 CONNECTORS .....................................................................................4-96 6.3 CD-RTB (4-PORT ROUTER)...........................................................................4-97 6.3.1 DESCRIPTION......................................................................................4-97 6.3.2 INSTALLATION......................................................................................4-99 6.3.3 LED INDICATIONS................................................................................4-99 6.4 CD-ETIA (GIGABIT POE SWITCH) ................................................................4-100 6.4.1 DESCRIPTION....................................................................................4-100 6.4.2 INSTALLATION....................................................................................4-101 6.4.2.1 STACKING ARCHITECTURE .....................................................4-101 6.4.2.2 CD-CP00 IP ADDRESS ASSIGNMENT ......................................4-101 6.4.2.3 GROUP FORMATION................................................................4-102 6.4.2.4 PORT NUMBER DETERMINATION..............................................4-102 6.4.2.5 UNMANAGED SWITCH FUNCTIONS ...........................................4-103 6.4.3 LED INDICATIONS..............................................................................4-103 6.4.4 CONNECTORS ...................................................................................4-103 SECTION 7 CABLING AND MDF CONNECTION ..............................................4-104 7.1 CONNECTION REQUIREMENTS ......................................................................4-104 7.2 CABLING PRECAUTIONS ...............................................................................4-104 VI CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

7.3 WIRING BETWEEN THE CHASSIS AND THE MDF .............................................4-104

7.3.1 CHASSIS CABLES ..............................................................................4-104 7.3.2 OUTSIDE LINES .................................................................................4-108 Chapter 5; Installing DT300/DT700 Series (DTL/ITL) Digital and IP Multiline Terminals SECTION 1 GENERAL INFORMATION..................................................................5-1 SECTION 2 DT300 SERIES DIGITAL MULTILINE TERMINALS ...............................5-7 2.1 DIGITAL MULTILINE TERMINALS .........................................................................5-7 2.1.1 DTL-2E-1( ) (BK) TEL..........................................................................5-7 2.1.2 DTL-6DE-1( ) (BK) TEL .......................................................................5-8 2.1.3 DTL-8LD-1( ) (BK) TEL/ DTL-8LD-1( ) (WH) TEL ................................5-8 2.1.4 DTL-12BT-1( ) (BK) TEL......................................................................5-9 2.1.5 DTL-12D-1( ) (BK) TEL/ DTL-12D-1( ) (WH) TEL ..............................5-10 2.1.6 DTL-12PA-1( ) (BK) TEL.................................................................... 5-11 2.1.7 DTL-24D-1( ) (BK) TEL/ DTL-24D-1( ) (WH) TEL ..............................5-12 2.1.8 DTL-32D-1( ) (BK) TEL/ DTL-32D-1( ) (WH) TEL ..............................5-13 SECTION 3 DT700 SERIES IP MULTILINE TERMINALS......................................5-15 3.1 IP MULTILINE TERMINALS ...............................................................................5-15 3.1.1 ITL-2E-1( ) (BK) TEL..........................................................................5-15 3.1.2 ITL-6DE-1( ) (BK) TEL.......................................................................5-16 3.1.3 ITL-8LD-1( ) (BK) TEL/ ITL-8LD-1( ) (WH) TEL .................................5-16 3.1.4 ITL-12D-1( ) (BK) TEL/ ITL-12D-1( ) (WH) TEL .................................5-17 3.1.5 ITL-12PA-1( ) (BK) TEL .....................................................................5-18 3.1.6 ITL-24D-1( ) (BK) TEL/ ITL-24D-1( ) (WH) TEL .................................5-19 3.1.7 ITL-32D-1( ) (BK) TEL/ ITL-32D-1( ) (WH) TEL .................................5-20 3.1.8 ITL-320C-1( ) (BK) TEL .....................................................................5-21 SECTION 4 INSTALL MULTILINE TERMINALS ....................................................5-23 4.1 CONNECTING THE DT300 SERIES MULTILINE TERMINAL TO THE SYSTEM ..........5-23 4.2 APPLYING POWER TO THE DT700 MULTILINE TERMINALS.................................5-24 4.3 CONNECTING THE IP MULTILINE TERMINAL TO THE NETWORK AND PC ..............5-25 4.4 ADJUSTING THE LCD ON THE MULTILINE TERMINAL..........................................5-26 4.5 INSTALLING LINE KEY KIT (12LK-L KIT) ..........................................................5-27 4.5.1 INSTALLING THE 12LK-L KIT................................................................5-27 4.5.2 CONFIGURING THE DIGITAL TELEPHONE FOR THE CORRECT NUMBER OF LINE KEYS......................................................................................5-32 System Hardware Manual VI CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

4.5.3 CONFIGURING THE IP TELEPHONE FOR THE CORRECT NUMBER

OF LINE KEYS......................................................................................5-32 4.6 INSTALLING THE DIRECTORY CARD ON THE MULTILINE TERMINAL......................5-34 4.7 REMOVAL AND REPLACEMENT OF THE NUMBERED KEYPADL .............................5-35 4.7.1 REMOVING THE NUMBERED KEYPAD.....................................................5-36 4.7.2 INSTALLING THE NUMBERED KEYPAD ....................................................5-37 4.8 REMOVAL AND REPLACEMENT OF THE BS ( )-L KIT (TEN KEY KIT).....................5-38 4.8.1 REMOVE THE BS ( ) – L KIT ................................................................5-38 4.8.2 INSTALL THE BS ( ) - KIT .....................................................................5-39 4.8.3 CONFIGUREING THE DIGITAL TELEPHONE FOR THE TEN KEY KIT ...........5-41 4.8.4 CONFIGUREING THE IP TELEPHONE FOR THE NUMBERED KEY ..............5-41 4.9 ADJUSTING THE HEIGHT ON THE MULTILINE TERMINAL .....................................5-43 4.10 REMOVING OR INSTALLING THE TILT LEGS ON THE MULTILINE TERMINAL..........5-44 4.10.1 REMOVE TILT LEGS ..........................................................................5-44 4.10.2 INSTALL TILT LEGS.............................................................................5-45 4.11 WALL MOUNTING THE MULTILINE TERMINAL...................................................5-46 4.11.1 WALL MOUNTING A MULTILINE TERMINAL USING THE BASE PLATE.........5-46 4.11.1.1 ADJUSTING THE HANGER HOOK...............................................5-46 4.11.1.2 WALL MOUNTING THE MULTILINE TERMINAL..............................5-47 4.11.1.3 REMOVING THE MULTILINE TERMINAL FROM THE WALL MOUNTED BASE PLATE...........................................................5-49 4.11.1.4 WALL MOUNTING THE BASE ON A SWITCH BOX .........................5-50 SECTION 5 MULTILINE TERMINALS OPTIONAL EQUIPMENT ..............................5-51 5.1 DT300/DT700 SERIES TERMINAL OPTIONS ....................................................5-51 5.2 DT300/DT700 SERIES OPTIONAL TERMINAL EQUIPMENT ................................5-52 5.2.1 8LK-L (BK) UNIT/8LK-L (WH) UNIT .................................................5-52 5.2.1.1 INSTALLING THE 8LK-L UNIT ...................................................5-52 5.2.2 8LKD (LD)-L (BK) UNIT/8LKD (LD)-L (WH) UNIT..............................5-54 5.2.2.1 INSTALLING THE 8LKD(LD)-L UNIT ..........................................5-55 5.2.3 8LKI (LD)-L (BK) UNIT/8LKI (LD)-L (WH) UNIT.................................5-58 5.2.3.1 INSTALLING THE 8LKI(LD)-L UNIT ...........................................5-59 5.2.4 DCL-60-1( ) (BK) CONSOLE/DCL-60-1( ) (WH) CONSOLE ............5-62 5.2.4.1 INSTALLING THE DCL-60-1 CONSOLE .....................................5-63 5.2.5 LCD (BL)-L (BK) UNIT/LCD (BL)-L (WH) UNIT ................................5-67 5.2.6 PANEL( )-L UNIT ...............................................................................5-68 5.2.7 WM-L UNIT........................................................................................5-69 5.2.7.1 MOUNT MULTILINE TERMINAL ON WALL USING WM-L UNIT.........5-69 VIII CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

5.2.7.2 MOUNT MULTILINE TERMINAL ON WALL PLATE USING WM-L UNIT5-73

5.2.8 DSS WM-L UNIT ...............................................................................5-77 5.2.8.1 MOUNT DCL-60-1 CONSOLE ON WALL USING DSS WM-L UNIT 5-77 5.2.8.2 MOUNT DCL-60-1 CONSOLE ON WALL PLATE USING DSS WM-L UNIT ....................................................................5-78 SECTION 6 BLUETOOTH CORDLESS HANDSET ................................................5-80 6.1 BLUETOOTH CORDLESS HANDSET (BCH) INTERFACE ......................................5-80 6.2 SELECTING A LOCATION..................................................................................5-81 6.3 CONTROLS AND INDICATORS...........................................................................5-82 6.4 INSTALLING THE BLUETOOTH CORDLESS HANDSET ..........................................5-84 6.4.1 INSTALLING THE BLUETOOTH HANDSET CRADLE...........................5-84 6.4.2 WALL MOUNTING THE BLUETOOTH CRADLE ......................................5-90 6.4.3 REMOVE AND REPLACE HANDSET BATTERY ..........................................5-93 SECTION 7 BLUETOOTH HUB ADAPTER ..........................................................5-94 7.1 BLUETOOTH HUB ADAPTER (BHA) FEATURES .................................................5-94 7.1.1 INSTALLING THE BHA-L UNIT..............................................................5-94 7.1.2 PAIRING A BLUETOOTH DEVICE AND MULTILINE TRMINAL (BLUETOOTH INSTALLED) .....................................................................5-96 7.1.2.1 ACCESSING THE BLUETOOTH DEVICE SETUP SCREEN ................5-96 7.1.2.2 ENTERING A PIN CODE .............................................................5-96 7.1.2.3 PAIRING....................................................................................5-96 7.1.2.4 CONNECTING THE PAIRED DEVICE .............................................5-97 7.1.2.5 UNPAIRING ...............................................................................5-97 7.1.2.6 VISIBILITY SETTING ...................................................................5-97 7.1.2.7 BT INFORMATION ......................................................................5-98 SECTION 8 SINGLE LINE TELEPHONE .............................................................5-99 8.1 INSTALLING THE IP1E-1SLTAD ......................................................................5-99 8.2 WALL MOUNTING THE IP1E-1SLTAD............................................................5-100 Chapter 6; Installing SV8100 Optional Equipment SECTION 1 GENERAL INFORMATION..................................................................6-1 SECTION 2 IP1WW-2PGDAD..........................................................................6-1 2.1 USING A IP1WW-2PGDAD..............................................................................6-1 2.2 LED INDICATION ..............................................................................................6-2 2.3 SETTING UP IP1WW-2PGDAD CONNECTIONS .................................................6-2 SECTION 3 BACKGROUND MUSIC ...................................................................6-11 3.1 INSTALLING BACKGROUND MUSIC ................................................................... 6-11 System Hardware Manual IX CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SECTION 4 DOOR BOX ............................................................................................6-12

4.1 INSTALLING A DOOR BOX ................................................................................6-12 SECTION 5 EXTERNAL PAGING .......................................................................6-16 5.1 EXTERNAL PAGE ............................................................................................6-16 5.2 INSTALLING AN EXTERNAL PAGE SYSTEM.........................................................6-16 SECTION 6 EXTERNAL PAGING AND DOOR BOX/PAGE RELAYS........................6-18 6.1 EXTERNAL PAGE RELAYS................................................................................6-18 6.2 DOOR BOX /EXTERNAL PAGE RELAY CONTACTS ..............................................6-19 6.2.1 CONNECTING A CONTACT RELAY DEVICE TO A DOOR BOX /EXTERNAL PAGE RELAY......................................................................6-19 SECTION 7 EXTERNAL RECORDING SYSTEM/EXTERNAL RINGER ....................6-20 7.1 EXTERNAL RECORDING SYSTEM OR EXTERNAL RINGER...................................6-20 7.2 INSTALLING AN EXTERNAL RECORDING SYSTEM OR EXTERNAL RINGER ............6-21 7.3 PROGRAMMING..............................................................................................6-21 SECTION 8 MUSIC SOURCES .........................................................................6-25 8.1 MUSIC ON HOLD ............................................................................................6-25 8.2 INSTALLING EXTERNAL MUSIC ON HOLD ..........................................................6-25 SECTION 9 TELEPHONE LABELING .................................................................6-28 9.1 DESI PRINTER SHEETS..................................................................................6-28 9.1.1 REMOVING THE FACEPLATE..................................................................6-28 9.1.2 REPLACING THE FACEPLATE.................................................................6-28 SECTION 10 TELEPHONE ADAPTERS ..............................................................6-29 10.1 USING ADAPTERS ........................................................................................6-29 10.2 IN-LINE POWER ADAPTER (ILPA-R)...............................................................6-30 10.2.1 CONDITIONS......................................................................................6-30 10.2.2 INSTALLATIONS..................................................................................6-31 10.3 ADA-L UNIT ...............................................................................................6-33 10.3.1 ADA-L UNIT SWITCH SETTINGS ........................................................6-34 10.3.2 INSTALLING THE ADA-L UNIT ............................................................6-36 10.3.3 ADA-L UNIT CONNCTION..................................................................6-38 10.3.3.1 ADA-L UNIT CONNECTION FOR RECORDING ONLY ..................6-38 10.3.3.2 ADA-L UNIT CONNECTION FOR SENDING RECORDED CALLS TO THE TELEPHONE ..............................................................6-39 10.4 APR-L UNIT ...............................................................................................6-39 10.4.1 APR-L UNIT SWITCH SETTINGS ........................................................6-40 10.4.2 INSTALLING THE APR-L UNIT ............................................................6-40 10.5 PSA-L (BK) UNIT / PSA-L (WH) UNIT........................................................6-43 X CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

10.5.1 INSTALLING THE PSA-L ADAPTER.......................................................6-44

10.5.2 USING THE PSA-L ADAPTER ..............................................................6-51 SECTION 11 POWER FAILURE TELEPHONES....................................................6-52 11.1 POWER FAILURE ..........................................................................................6-52 11.2 CONNECTOR PIN-OUTS ON COIU BLADE FOR POWER FAILURE CIRCUITS.......6-53 11.3 INSTALLING THE POWER FAILURE TELEPHONES..............................................6-53 System Hardware Manual XI CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

R-1 Regulatory BATTERY DISPOSAL The UNIVERGE SV8100 system includes the batteries listed below. When disposing of these batteries, Chassis, and/or Blades, you must comply with applicable federal and state regulations regarding proper disposal procedures. Unit Name Type of Battery Quantity CD-CP00 Lithium 1 CT-12 Headset Cordless Ni MH 1 DTH-4R-2 Ni MH 1 DTL-8R-1 Ni MH 1 DTR-1HM-1 TEL Lithium 1 DTR-1R-2 Nickel-Cadmium 1 DTR-4R-2 TEL Nickel-Cadmium 1 DTU-4R-1 TEL Lead Acid 1 C124 (SIP DECT Wireless) Ni MH 1 CHS LARGE BATT SET Sealed Lead 1 Headset Cordless II Ni MH 1 Internal Batteries Sealed Lead 1 Bluetooth® Cordless Handset Lithium-ion 1 Table R-1 Battery Types and Quantities for Chassis and Blades The UNIVERGE SV8100 CD-CP00 provides memory backup for approximately three years. The Lithium battery should be replaced every two years. IMPORTANT SAFEGUARDS FOR BATTERY DISPOSAL DO NOT PLACE USED BATTERIES IN YOUR REGULAR TRASH! THE PRODUCT YOU PURCHASED CONTAINS LITHIUM, NICKEL-CADMIUM OR SEALED LEAD BATTERIES. LITHIUM, NICKEL-CADMIUM OR SEALED LEAD BATTERIES MUST BE COLLECTED, RECYCLED, OR DISPOSED OF IN AN ENVIRONMENTALLY SOUND MANNER. The incineration, landfilling or mixing of nickel-cadmium or sealed lead batteries with the municipal solid waste stream is PROHIBITED BY LAW in most areas. Contact your local solid waste management officials for other information regarding the environmentally sound collection, recycling, and disposal of the battery. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Nickel-Cadmium (or sealed lead) batteries must be returned to a federal or state approved

nickel-cadmium (or sealed lead) battery recycler. This may be where the batteries were originally sold or a local seller of automotive batteries. Contact your local waste management officials for other information regarding the environmentally sound collection, recycling and disposal of the battery contained in this product. The packaging for the UNIVERGE SV8100 system contains the following labels regarding proper disposal. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

EUROPEAN UNION INFORMATION

Notice to the user The system described in this manual is intended to be connected to analog and digital networks and supports a wide range of peripheral equipment. The following interfaces are available for connection to public analog and digital telecommunication networks: TBR3 ISDN basic rate interface TBR4 ISDN primary rate interface ES203-021 Analogue interface To take advantage of all features of this system and the connected equipment, the country or network specific features should match the supported features of the system. For an overview of the supported features, refer to the detailed documentation that comes with this system, contact your local supplier. Declaration of conformityHereby, “NEC Infrontia”, declares that the SV8100 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Electromagnetic Compatibility For the SV8100 system the following warning is applicable: Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. System Hardware Manual R-3 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

PRODUCT DISPOSAL INFORMATION

For Countries in the European Union The symbol depicted here has been affixed to your product in order to inform you that electrical and electronic products should not be disposed of as municipal waste. Electrical and electronic products including the cables, plugs and accessories should be disposed of separately in order to allow proper treatment, recovery and recycling. These products should be taken to a designated facility where the best available treatment, recovery and recycling techniques are available. Separate disposal has significant advantages: valuable materials can be re-used and it prevents the dispersion of unwanted substances into the municipal waste stream. This contributes to the protection of human health and the environment. Please be informed that a fine may be imposed for illegal disposal of electrical and electronic products via the general municipal waste stream. In order to facilitate separate disposal and environmentally sound recycling arrangements have been made for local collection and recycling. In case your electrical and electronic products need to be disposed of please refer to your supplier or the contractual agreements that your company has made upon acquisition of these products. Battery information Defective or exhausted batteries should never be disposed of as municipal waste. Return old batteries to the battery supplier, a licensed battery dealer or a designated collection facility. Do not incinerate batteries. This product uses Lithium batteries. Do not use any other type. For an overview of the location of batteries used in these systems, the battery replacement or removal instructions please refer to the UNIVERGE SV8100 System Hardware Manual. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

1-1 Chapter1; Introduction to SV8100 SECTION 1 GENERAL INFORMATION The SV8100 is a full-featured IP based communications system providing a rich feature set of existing system, with pure Voice over IP (VoIP) communications, across corporate Local and Wide Area Networks (LAN and WAN). The DT700 series telephones provide a converged infrastructure at the desktop, with a 10Base-T/100Base-TX connection to the LAN and built-in hub for a PC connection to the telephone itself. The system can provide peer-to-peer connections between the DT700 series telephones with voice compression, offering existing IP telephone features with an enhanced user interface. On the WAN side, the system can provide peer-to-peer connections over IP networks with the voice compression, on CCIS over IP or Remote Unit over IP. The SV8100 can provide legacy line/trunk interfaces to support the existing Time Division Multiplexing (TDM) based infrastructure, such as analog telephones, digital telephones (DT300 series), analog networks and digital networks (T1/E1, ISDN, etc.). The new compact 19” chassis provides 111 total ports (80 digital terminals) and can be expanded, using three additional 19” chassis, for a maximum of 444 ports (368 digital terminals). Through IP connection and four additional 19” chassis, the system can be expanded to a maximum of 512 ports for SV8100 (refer to Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels on page 2-5). Communications between legacy stations/trunks and DT700 series telephones/IP networks are made using a VoIP daughter board, which converts packet-based voice data to TDM-based voice data, and vice versa. Both peer-to-peer connections and TDM-based connections are controlled by the CPU blade. The CPU incorporates a built-in Device Registration Server (DRS) and a single interface point of IP connection to IP telephone, PCPro and OAI / ACD servers. Figure 1-1 shows a simplified view of SV8100 system connectivity. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Introduction to SV8100

1-2 (via TCP/IP) SP310 Softphone Figure 1-1 Simplified SV8100 System Connectivity Highlights of the UNIVERGE SV8100 are as follows:  Pure IP System capable TDM configuration The SV8100 supports both pure IP switching (peer-to-peer connections) and Time Division Switching. The pure IP switching is provided for communications between DT700 series telephones and for CCIS / Remote Unit connections with other SV8100. On the other hand, the TDM switching is provided for communications between legacy stations/trunks. Connection between IP network and legacy network is made via VoIP daughter board on the CPU blade, which converts packet-based voice data to TDM-based voice data, and vice versa. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

1-3  Powerful CPU Blade with Built-in Functionalities The CPU blade of SV8100 is a heart of pure IP connections and TDM-based connections. The CPU blade employs a 32 bit microprocessor. With this processing power and DSP technology, it integrates the following functions on one board. Some of these functions are managed with software licenses.  DTMF receivers  Caller ID receivers  Caller ID senders  MF senders / receivers  10/100 Ethernet Port  2 Control Relays  MOH Input Port  Paging Output Port  In-Mail (VMDB)  VoIP In addition, by means of advanced LSI technology, size of the CPU blade is minimized, O&M NIC port (10/100M) is built in and VoIPDB which has VoIP NIC port (Gigabit Ethernet) is mountable without additional slots in the chassis. The O&M NIC port is linked with LAN/WAN for inter-work with PCPro, SMDR, OAI server, and the VoIP NIC port is linked with LAN/WAN for control signaling and voice signaling (RTP) for DT700 series.  High Density Legacy Line/Trunk Blades Major legacy line/trunk blades used in SV8100 are provided with blade + daughter board architecture. When the blade is mounted only in an initial supply, line/trunk interfaces can be easily expanded by adding the daughter board. The maximum number of ports for the line/trunk blades is 8/16 ports with daughter blade, respectively. This allows the physical system size to be compact. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Introduction to SV8100

1-4  Universal Blade Slot (19” Chassis) A 19” Chassis is used for legacy line/trunk blades. One 19” Chassis provides six universal slots and one expansion slot. Also, the universal slots can be used for special application blades without complicated limitation. This makes easy quotation and installation.  Easy Installation (Front Cabling and Enhanced O&M Tool) Cable connectors (RJ-45 or RJ-61) are located on the front panel of each chassis and blade. This increases efficiency of the cabling work. Also, PCPro provides an enhanced user interface. A Quick Setup tool provides easy setup (system data programming) for a basic system configuration in shorter time. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

1-5 SECTION 2 EQUIPMENT LIST The following tables list all equipment for the SV8100 systems. Table 1-1 Chassis Equipment List Equipment Name Equipment Description Remarks CHS2U 19” Chassis (6-slot) with Power Supply - AC Power Cable - Blank Slot Cover (5pcs.) - Bus Slot Cover (1pc) MPS7101 Power Supply Unit for CHS2U install into CHS2U Table 1-2 Chassis Installation Equipment List Equipment Name Equipment Description Remarks CHS BASE UNIT Floor Mount Kit for CHS2U CHS2U BLANK SLOT COVER KIT Blank Slot Cover for CHS2U(1pc) CHS BLANK SLOT COVER KIT (BUS) Blank Slot Cover for Bus slot(1pc) CHS2U JOINT BRACKET KIT Joint Bracket set to fix between upper and lower CHS2U and/or CHS BASE UNIT CHS2U RACK MOUNT KIT 19 inch Rack Mount Bracket for CHS2U CHS1U/2U WALL MOUNT KIT Wall Mount Set for CHS2U CHS2U FAN BOX SET FAN BOX for CHS2U install into CHS2U CHS2U STAND KIT (K) Stand Mount Kit for CHS2U CHS2U STAND KIT (EXT) Stand Mount Kit for CHS2U (expansion parts) Table 1-3 Battery Mount Equipment List Equipment Name Equipment Description Remarks CHS LARGE BATT BOX Long Term Battery Box for CHS2U Chassis (including following cables) Cable between batteries – 9.06in/230mm Fuse Unit to Batteries – 18.11in/460mm Cable from chassis to battery box – 81.1in/2060mm CHS2U BATT MTG KIT Short term internal battery mount kit for CHS2U, Backup time – 10 minutes CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Introduction to SV8100

1-6 Table 1-4 Blade Equipment List Equipment Name Abbreviations Equipment Description Remarks CD-CP00 CPU Main Processor Blade including main software PZ-BS10 BUS0 Bus Unit for System Expansion (for Main Chassis) PZ-BS11 BUS1 Bus Unit for System Expansion (for Expansion Chassis) with Cable PZ-VM21 VMDB Embedded VRS/VM Daughter Board with V34 Analog Modem PZ-32IPLA VoIPDB 32-channel VOIP on CCPU PZ-64IPLA VoIPDB 64-channel VOIP on CCPU PZ-128IPLA VoIPDB 128-channel VOIP on CCPU CD-8DLCA DLC 8-port Digital Station Interface PZ-8DLCB DLCDB 8-port Digital Station Interface on CD-8DLCA CD-16DLCA DLC 16-port Digital Station Interface CD-4COTA COT 4-port Loop Start Analog Trunks Interface PZ-4COTE COTDB 4-port Loop Start Analog Trunks Interface on CD-4COTA, CD-LTA/LTB CD-4LCA LC 4-port Analog Terminal Interface PZ-4LCA LCDB 4-port Analog Terminal Interface on CD-4LCA and CD-8LCA CD-8LCA LC 8-port Analog Terminal Interface PZ-8LCE LCDB 8-port Analog Terminal Interface on CD-4LCA and CD-8LCA CD-2BRIA BRT 2 Basic Rate Interface PZ-2BRIA BRTDB 2 Basic Rate Interface on CD-2BRIA CD-PRTA PRT 1 PRI/T1/E1 INTERFACE CD-4DIOPB DIOP 4 port Analog DID/OPX Interface CD-4ODTB ODT 4-port Analog E&M Tie Line Interface CD-RTB RTB In-Skin Router CD-VM00 VM00 In-skin VM/UMS CD-ETIA GSWU In-skin PoE Gigabit Switch Unit PZ-ME50 MEM Memory Expansion including main software on CD-CP00 CD-LTA LTA 8 Digital Station/2 Analog Terminal Interface CD-PVAA CNF Conference Bridge CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

1-7 Table 1-5 Optional Equipment List Equipment Name Equipment Description Remarks IP1WW-2PGDAD 2 ports External Paging / Doorphone / Audio Adapter IP1E-1SLTAD Analog Terminal Adapter for Digital Terminal Port DP-D-1A Doorphone Box AKS VRS OT Compact Flash for Inmail AKS VRS-VM OT Compact Flash for Inmail AKS UM-2G OT CF Card for VM/UMS (2GB: 125h Rec.) AKS UM-8G OT CF Card for VM/UMS (8GB: 550h Rec.) Table 1-6 Cable Equipment List Equipment Name Equipment Description Remarks CHS2U BATT CA INT CHS2U Battery Cable set for Internal Battery 2U Chassis Cable A – 18.9in/480mm Cable B – 3.15in/80mm Table 1-7 Digital Multi Terminal (DT300 Series) Equipment List Equipment Name Equipment Description Remarks DTL-2E-1( ) (BK) TEL Economy Digital 2-button Telephone (No-Display) DTL-6DE-1( ) (BK) TEL Economy Digital 6-button Display Telephone DTL-12D-1( ) (BK) TEL DTL-12D-1( ) (WH) TEL Value Digital 12-button Display Telephone DTL-24D-1( ) (BK) TEL DTL-24D-1( ) (WH) TEL Value Digital 24-button Display Telephone DTL-32D-1( ) (BK) TEL Value Digital 32-button Display Telephone DTL-12BT-1( ) (BK) TEL 12-button Display type Digital Terminal with Bluetooth Cordless Handset DTL-12PA-1( ) (BK) TEL Value Digital 12-button Telephone with Power Failure Adapter DTL-8LD-1( ) (BK) TEL DTL-8LD-1( ) (WH) TEL Value Digital 8-button Telephone (DESI-less) DCL-60-1( ) (BK) CONSOLE DCL-60-1( ) (WH) CONSOLE 60-button Direct Station Selection (DSS) Console 8LK-L( ) (BK) UNIT 8LK-L( ) (WH) UNIT 8-button Line Key Unit 8LKD (LD)-L (BK) UNIT 8LKD (LD)-L (WH) UNIT DESI-less 8-button Line Key Unit/LCD Unit for Digital Telephone CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Introduction to SV8100

1-8 Table 1-8 IP Multi Terminal (DT700 Series) Equipment List Equipment Name Equipment Description Remarks ITL-2E-1( ) (BK) TEL Value IP 12-button Telephone with Power Failure Adapter ITL-6DE-1( ) (BK) TEL Value IP 6-button Display Telephone ITL-8LD-1( ) (BK) TEL ITL-8LD-1( ) (WH) TEL Value IP 8 Line Key Display Telephone Value IP Telephone: DESI-less ITL-12D-1( ) (BK) TEL ITL-12D-1( ) (WH) TEL Value IP 12 Line Key Display Telephone ITL-24D-1( ) (BK) TEL ITL-24D-1( ) (WH) TEL Value IP 24 Line Key Display Telephone ITL-32D-1( ) (BK) TEL Value IP 32 Line Key Display Telephone ITL-12PA-1( ) (BK) TEL Value IP 12-button Telephone with Power Failure Adapter ITL-12BT-1( ) (BK) TEL 12-button Display type IP Terminal with Bluetooth Cordless Handset ITL-320C-1( ) (BK) TEL Sophisticated Telephone 8LKI (LD)-L (BK) UNIT 8LKI (LD)-L (WH) UNIT DESI-less LK/LCD Unit for IP Terminals CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

1-9 Table 1-9 DT300/DT700 Series Optional Equipment List Equipment Name Equipment Description Remarks APR-L( ) UNIT Analog Terminal Adapter with Ringer (DT300 Only) ADA-L( ) UNIT Recording Jack Adapter ILPA-R( ) UNIT In-Line Power Adapter for IP Terminal PSA-L( )(BK) UNIT PSA-L( ) (WH) UNIT Power Failure Transfer cradle BCH-L( ) (BK) UNIT Bluetooth Cordless Handset with cradle BHA-L( ) UNIT Bluetooth HUB Adapter 12LK-L (BK) KIT 12LK-L (WH) KIT Additional 12 keys for 12D / 12PA / 12BT TEL LCD (BL)-L (BK) UNIT LCD (BL)-L (WH) UNIT Backlit LCD Unit used only for DT300 Series WM-L UNIT Wall Mount kit for Terminal with Bottom Adapter DSS WM-L UNIT Wall Mount Unit for DSS Console in case terminal is using WM-L UNIT DESI ITL/DTL-2E (25 PKG) DESI Sheet for Economy 2-button Telephone (2 Labels per Sheet) DESI ITL/DTL-6DE (25 PKG) DESI Sheet for Economy 6-button Display Telephone (2 Labels per Sheet) DESI ITL/DTL-12D (25 PKG) DESI Sheet for Value 12-button Display Telephone (2 Labels per Sheet) DESI ITL/DTL-8LK (25 PKG) DESI Sheet for 8-button Line Key (2 Labels per Sheet) DESI DCL-60 (25 PKG) DESI Sheet for 60DSS (1 Label per Sheet) DESI ITL/DTL-SIDE (25 PKG) DESI Sheet for Clear Side Panel (Left and Right Label each Sheet) DESI ITL/DTL-SIDE-LCDV (25 PKG) DESI Sheet for Value Telephone LCD (Clear Side) DESI ITL/DTL-SIDE-LCDS (25 PKG) DESI Sheet for Sophisticated Telephone LCD (Clear Side) DESI ITL/DTL Directory Card Directory Card DESI ITL/DTL-24D (25 PKG) DESI Sheet for Value 24-button Display Telephone (2 Labels per Sheet) Panel (Red-Base)-L UNIT Color Side Panel for Base 2E/6DE TEL Panel (Red-VLCD)-L UNIT Color Side Panel for Value Telephone LCD (12D/24D/32D/8LD/12PA/12BT TEL) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Introduction to SV8100

1-10 Table 1-9 DT300/DT700 Series Optional Equipment List (Continued) Equipment Name Equipment Description Remarks Panel (Red-SLCD)-L UNIT Color Side Panel for Sophisticated Telephone LCD (320C TEL) Panel (Blue-Base)-L UNIT Color Side Panel for 2E/6DE TEL Panel (Blue-VLCD)-L UNIT Color Side Panel for Value Telephone LCD (12D/24D/32D/8LD/12PA/12BT TEL) Panel (Blue-SLCD)-L UNIT Color Side Panel for Sophisticated Telephone LCD (320C TEL) Panel (Wood-Base)-L UNIT Color Side Panel for 2E/6DE TEL Panel (Wood-VLCD)-L UNIT Color Side Panel for Value Telephone LCD (12D/24D/32D/8LD/12PA/12BT TEL) Panel (Wood-SLCD)-L UNIT Color Side Panel for Sophisticated Telephone LCD (320C TEL) Panel( Logo-Base)-L UNIT Color Side Panel for all terminal (terminal base only) Panel (Clear-Base)-L UNIT Color Side Panel for 2E/6DE TEL Panel (Clear-VLCD)-L UNIT Color Side Panel for Value Telephone LCD (12D/24D/32D/8LD/12PA/12BT TEL) Panel (Clear-SLCD)-L UNIT Color Side Panel for Sophisticated Telephone LCD (320C TEL) LKPANEL(12BTN)-L(M-Blue) UNIT Color LK panel(12button) for Value(Metallic Blue) LKPANEL(12BTN)-L(GUNMET A) UNIT Color LK panel(12button) for Value(GunMetallic) LKPANEL(12BTN)-L(L-Green- M) UNIT Color LK panel(12button) for Value(LimeGreen Metallic) LKPANEL(12BTN)-L(Orange-M ) UNIT Color LK panel(12button) for Value(Orange Metallic) LKPANEL(12BTN)-L(D-Brown- M) UNIT Color LK panel(12button) for Value(DarkBrown Metallic LKPANEL(24BTN)-L(M-Blue) UNIT Color LK panel(12button) for Value(Metallic Blue) LKPANEL(24BTN)-L(GUNMET A) UNIT Color LK panel(12button) for Value(GunMetallic) LKPANEL(24BTN)-L(L-Green- M) UNIT Color LK panel(12button) for Value(LimeGreen Metallic) LKPANEL(24BTN)-L(Orange-M ) UNIT Color LK panel(12button) for Value(Orange Metallic) LKPANEL(24BTN)-L(D-Brown- M) UNIT Color LK panel(12button) for Value(DarkBrown Metallic) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

1-11 Table 1-9 DT300/DT700 Series Optional Equipment List (Continued VAL DIRECTORY CARD UNIT(L) Directory Card Holder for Value Telephone ECO DIRECTORY CARD UNIT(L) Directory Card Holder for Economy Telephone Table 1-10 License List Equipment Name Equipment Description Remarks LK-SYS-UNLIMT PORT-LIC Unlimited port license in case more than 256 ports License (Capacity) LK-SYS-1ST-CTI1-LIC 1st Party CTI (over Ethernet) license (require per client) LK-SYS-3RD-CTI-CLIENT-LIC 3rd Party CTI license License (CTI) LK-SYS-ACD-CLIENT1-LIC ACD Client license (require per client) LK-SYS-ACD-PEVENT-LIC ACD P-Event for MIS license License (ACD) LK-SYS-IP-TRUNK1-LIC IP Tunk (SIP / H323) license LK-SYS-IP-TERMINAL-1-LIC IP Terminal (SIP-MLT / Softphone) license LK-SYS-IP-TERMINAL-SIP1-LI C IP Terminal (SIP-MLT / Softphone / SIP SLT / 3rd Party) license License (IP) LK-SYS-NET LINK1-LIC NetLink license (require per remote node) LK-SYS-KCCIS-IP-LIC K-CCIS over IP license (require per channel) LK-SYS-FEATURE-NETWORK NG-LIC AspireNet over IP license License (Networking) LK-SYS-HM-LIC Hotel/Motel (including PMS) license LK-SYS-OAI-LIC OAI Activation license License (Application I/F) LKS-VM-LANGUAGE1-LIC Embedded VRS/VM Multi-Language license License (Embedded VRS/VM) LKS-DESKTOP SUITE-SOFTPHONE1-LIC SP310 (Softphone) license LKS-DESKTOP SUITE-ENHANCE PKG1-LIC Enhancement package (Presence, White Board, File TRFR, IM) license LK-DESKTOP SUITE-PC ASSISTANT1-LIC PC Assistant (Basic) license LK-DESKTOP SUITE-PC ATTENDANT1-LIC PC Attendant (Superior) license License (Desktop Application) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Introduction to SV8100

1-12 Table 1-10 License List (Continued) Equipment Name Equipment Description Remarks LKS-UMS-PORT2 LITE-LIC UMS Lite Mail port (2 ports) license LKS-UMS-PORT4 LITE-LIC UMS Lite Mail port (4 ports) license LKS-UMS-PORT8 LITE-LIC UMS Lite Mail port (8 ports) license LKS-UMS-PORT16 LITE-LIC UMS Lite Mail port (16 ports) license LKS-UMS-PORT2 LITE UPG KIT-LIC 2-Ports LITE Upgrade Kit license LKS-UMS UPG FM LITE TO FULL-LIC Upgrade license from LITE Mail to FULL UMS LKS-UMS-PORT4 -LIC UMS port (4 ports) license LKS-UMS-PORT8 -LIC UMS port (8 ports) license LKS-UMS-PORT16 -LIC UMS port (16 ports) license LKS-UMS-CLIENT1-LIC UMS Client (view appli) license (1 client) LKS-UMS-CLIENT4-LIC UMS Client (view appli) license (4 clients) LKS-UMS-CLIENT8-LIC UMS Client (view appli) license (8 clients) LKS-UMS-CLIENT16-LIC UMS Client (view appli) license (16 clients) LKS-UMS-CLIENT32-LIC UMS Client (view appli) license (32 clients) LKS-UMS VIDEO MAIL CLIENT1-LIC Video Mail Client license (1 client) LKS-UMS VIDEO MAIL CLIENT5-LIC Video Mail Client license (5 clients) LKS-UMS-FAX-LIC UMS Fax port license LKS-UMS-TTS-PORT-LIC UMS TTS port license LKS-UMS-LANGUAGE1-LIC UMS Multi-Language license LKS-UMS-HOTEL-PMS-LIC UMS Hospitality / PMS license LKS-UMS-HOTEL-LANGUAG E-LIC UMS Hospitality Language license LKS-UMS-AMIS-PLUS-LIC UMS Amis/Plus Net license LKS-UMS-TTS-LANGUAGE-LI C UMS TTS Language license LKS-UMS-MAIL-MANAGER-LI C UMS Mail Manager license License (In-Skin UMS) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

2-1 Chapter2; SV8100 System Specifications SECTION 1 GENERAL INFORMATION This chapter provides detailed specifications for the SV8100 system technician. The technician should review this information carefully before installing the system. SECTION 2 SYSTEM BLOCK DIAGRAM Figure 2-1 SV8100 System Block Diagram on Page 2-4 shows the Blades that can be installed in the chassis and the number of channels supported when the Blade is installed. Table 2-1 List of Abbreviations lists abbreviations used in the diagram. Table 2-1 List of Abbreviations Abbreviation Description ACD Automatic Call Distribution ADA Ancillary Devise Adapter APR Analog Port Adapter (with ringer) AUX IN/OUT BGM/MOH Port (on CD-CP00) BCH Bluetooth Cordless Handset BHA Bluetooth Hub Adapter BRI Basic Rate Interface BRIDB Expansion Basic Rate Interface Blade on BRI BRT Basic Rate Interface Blade/ISDN Terminal Interface Blade BUS0 BUS Interface Blade (For Control Chassis) BUS1 BUS Interface Blade (For Expansion Chassis) CCT CCIS Interface Blade CF Compact Flash CFT Conference Trunk (on CD-CP00) CNF Conference Bridge Blade (PVA) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-2 Table 2-1 List of Abbreviations (Continued) Abbreviation Description COT Central Office Trunk (Loop and Ground Start Interface) COTDB Expansion Loop and Ground Start Interface Blade on COT CPU Central Processing Unit DID Direct Inward Dialing DIOP DID/OPX Blade DLC Digital Multiline Terminal Interface Blade DLCB Expansion Digital Multiline Terminal Interface Blade on DLC DRS Device Registration Server (on CPU) DSS Direct Station Selection Console DTI Digital Trunk Interface DTG Digital Tone Generator (on CPU) E1 E-carrier system ( European Digital Transmission Format) ETHERNET Ethernet Port (on CPU) FT1 Fractional T1 GSWU Power over Ethernet Gigabit Switch IDF Intermediate Distribution Frame IPT IP Trunk (P2P CCIS) (on CPU) ISDN Integrated Service Digital Network LAN Local Area Network LC Single Line Telephone Interface Blade LCDB Expansion Single Line Telephone Interface Blade on LC MDF Main Distribution Frame MEM Main Memory (on CPU) MIS Management Information System MOH Music On Hold OAI Open Application Interface (on CPU) ODT Tie Line Interface Blade (2W/4W E&M) OPX Off-Premise Extension PBR PB Receiver (on CPU) PBSND PB Sender (on CPU) PCPro PC Programming PFT Power Failure Transfer PLO Phase Locked Oscillator (on CPU) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Table 2-1 List of Abbreviations (Continued)

Abbreviation Description PMS Property Management System PRI Primary Rate Interface PRT Primary Rate Interface Blade PS Personal Station PSA PSTN Adapter (analog) PVA Packet Voice Application RTB Router Blade SERIAL Serial Port (on CPU) SLT Single Line Telephone SMDR Station Message Detail Recording TDSW Time Division Switch (on CPU) USB Universal Serial Bus (on CPU) CD-VM00 UMS Blade Server Blade PZ-VM21 VMS Daughter Board with V34 Modem VMS Voice Mail System VoIP Voice over Internet Protocol VoIPDB VoIP daughter board (on CPU) VRS Voice Response System WAN Wide Area Network WebPro Web-Based PC Programming System Hardware Manual 2-3 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-4 Figure 2-1 SV8100 System Block Diagram CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

2-5 SECTION 3 MAXIMUM SYSTEM CAPACITIES The CHS2U is a compact 19” chassis that has six universal slots, one expansion slot and one MPS7101 (power supply unit). When the CD-CP00 is installed in the first CHS2U, it is referred to as the Controlling Chassis. Additional chassis, referred to as Expansion Chassis, can be installed to increase the capacity of the system to meet the customer’s business needs. As Figure 2-2 19” Controlling and Expansion Chassis and Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels illustrate, the system can be expanded from 111 ports to 512 ports by vertically stacking a maximum of three additional chassis onto the controlling chassis. This provides a maximum of 24 slots and 368 digital terminals. To obtain the maximum port capacity of 512 ports, two systems can be linked together via an IP connection. The maximum slot and channel capacities are listed in Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels. Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels 19" Chassis Number of: x1 (6 slots) x2 (12 slots) x3 (18 slots) x4 (24 slots) System Maximum Number of Timeslots 111 222 333 444 444 Dterm(-48V) 80 176 272 368 SLT(-28V) 80 176 272 368 SLT(-48V) 20 44 68 92 DtermIP 512 SIP/WAN 512 Total 512 Analog Trunks (COT) 40 88 136 184 BRI 40 88 136 184 PRI (30B) 90 180 180 180 IP Trunk (SIP) 200 Total 200 VoIP Channels 128 Conference Circuits 64 (32 parties max per Conference) Voice Mail Channels on CPU 16 channels V34 Modem 1 channel DTMF Receivers 32 32 32 32 96 *1 *1 = An additional 64 DTMF Receivers are available when the PZ-BS10 is installed.  An additional 64 DTMF Receivers are available when the PZ-BS10 is installed. If using Caller ID to analog trunks and DSP resources are set to common, DSP resources will only be used for analog trunks and not analog stations. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-6 3.1 System Configuration – SV8100 The SV8100 19” chassis provides 111 total ports (80 digital terminals) and can be expanded, using three additional 19” chassis, for a maximum of 444 ports (368 digital terminals). Through IP connection and use of additional 19” chassis, the system can be expanded to a maximum of 512 ports. The 19” chassis consists of a controlling chassis (chassis with CD-CP00 blade), and the ability to expand the system using expansion blades depending on system configuration. Figure 2-2 19” Controlling and Expansion Chassis CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

2-7 Table 2-3 Maximum System Capacities – Chassis shows the maximum number of chassis and related equipment that can be installed in a system. Table 2-3 Maximum System Capacities – Chassis Hardware 19” Chassis with CPU 19” Chassis without CPU 19” Chassis x4 Number of Slot(s) for Interface Package 5 Slots 6 Slots 23 Slots Networked Chassis Comments Chassis: CHS2U (19” Chassis) 1 1 4 16x(1+3) Virtual slot in NetLink is limited to maximum of 240 Expansion: PZ-BS10 3-jack Expansion Board for Controlling Chassis 1 0 1 16x1 - PZ-BS11 1-jack Expansion Board for Expansion Chassis 0 1 3 16x3 - Battery: CHS LARGE BATT BOX (External Battery Box) 1 1 4 16x(1+3) - Fan Box: CHS2U FAN BOX SET 1 1 4 - 1 is factory installed with each chassis Power Supply: MPS7101 1 1 4 - 1 is factory installed with each chassis Table 2-4 SV8100 Maximum System Capacities – Blades shows the maximum number for each blade that can be installed in a system. This is determined by the maximum blade configuration allowed. When installing single line sets, DISA, or tie lines, CPU circuits must be allocated for DTMF receivers. To install single line sets with CO/PBX line access, or when installing immediate-start tie lines, CPU circuits must be allocated for dial tone detection. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-8 Table 2-4 SV8100 Maximum System Capacities – Blades Hardware 19” Chassis with CPU 19” Chassis without CPU 19” Chassis x4 Number of Slot(s) for Interface Package 5 Slots 6 Slots 23 Slots Networked Chassis Comments Common Control Blades: CD-CP00 1 0 1 16 Main Processor Board PZ-32IPLA (32-port VoIP Daughter Board) 1 0 1 16 This unit provides 32 VOIP Gateway channels PZ-64IPLA (64-port VoIP Daughter Board) 1 0 1 16 This unit provides 64 VOIP Gateway channels PZ-128IPLA (128-port VoIP Daughter Board) 1 0 1 16 This unit provides 128 VOIP Gateway channels PZ-ME50 (Memory Expansion Board) 1 0 1 16 PZ-VM21 (Voice Mail Daughter) 1 0 1 1 Does include modem Station Blades: CD-4DIOPB (4 DID/OPX) 5 6 23 50 When installed as an OPX blade CD-4LCA (4 Single Line Telephone Interface) 5 6 23 32 - CD-8LCA (8 Single Line Telephone Interface) 5 6 23 32 CD-8DLCA (8 Digital Station Interface) 5 6 23 32 CD-16DLCA (16 Digital Station Interface) 5 6 23 32 PZ-8DLCB (8 Digital Station Interface Daughter Board) 5 6 23 32 PZ-4LCA (4 Single Line Telephone Interface Daughter Board) 5 6 20 32 - CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

2-9 Table 2-4 SV8100 Maximum System Capacities – Blades(continued) Hardware 19” Chassis with CPU 19” Chassis without CPU 19” Chassis x4 Number of Slot(s) for Interface Package 5 Slots 6 Slots 23 Slots Networked Chassis Comments Station Blades: PZ-8LCE(8 Single Line Telephone Interface Daughter Board) 5 6 23 32 CD-LTA (8 Digital/2 Single Line) 1 1 4 5 An optional PZ-4COTE or PZ-2BRIA can be installed Trunk Blades: CD-2BRIA (2 Basic Rate Interface) 5 6 23 25 - PZ-2BRIA (2 Basic Rate Interface Daughter Board) 5 6 23 25 - CD-4COTA (4 Loop Start Trunk) 5 6 23 25 - PZ-4COTE(4 Loop Start Trunk Daughter Board) 5 6 23 25 - CD-4DIOPB (4 DID/OPX) 5 6 23 50 When installed as a DID blade CD-4ODTB (4 E&M) 5 6 23 50 - CD-PRTA(1 Primary Rate Interface/T-1/E-1) 3 3 6 6 Blade is used for Primary Rate Interface or T-1 Interface or E-1 Optional Blades: CD-PVAA (Conference Bridge) 5 6 23 32 CD-ETIA (Switching Hub with Power over Ethernet) 3 3 12 64 CD-RTB (Router) 1 2 7 50 CD-VM00 (Voice Mail and Server) 1 1 1 1 Maximum of One per system CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-10 Table 2-5 Daughter Board Combinations shows each blade and associated daughter board combinations. The daughter boards that can be mounted on specific blades are indicated by a checkmark. For example, the CD-4COTA can have a PZ-4COTE daughter board mounted. Table 2-5 Daughter Board Combinations Daughter Board Controlling Chassis PZ-2BRIA PZ-4COTE PZ-4LCA PZ-8LCE PZ-8DLCB CD-LTA (8 Digital/2 Single Line) ○ ○ - - - CD-4COTA (4 Loop Ground Start) - ○ - - - CD-4LCA (4 Single Line Interface) - - ○ ○ - CD-8LCA( 8 Single Line Interface) - - ○ ○ - CD-8DLCA (8 Digital Station Interface) - - - - ○ CD-16DLCA (16 Digital Station Interface) - - - - - CD-2BRIA (2 Basic Rate Interface) ○ - - - - - : Does not apply / ○ : Does apply CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

2-11 SECTION 4 POWER-BASED CALUCULATOR CHART The UNIVERGE SV8100 system uses two types of power factors. For a single chassis chart refer to Table 2-6 Board Power Factor. For the maximum number of specific blades per package, see Table 2-7 Maximum Number of Package Installed. Refer to Table 2-8 Terminal Power Factor on Page 2-12 below, for the Terminal/ Adapter power chart. Table 2-6 Board Power Factor Board Power Factor Total =< 7 Item Power Factor CD-CP00 1 CD-RTB 2 CD-VM00 2 CD-ETIA 2 CD-PVAA 1 PZ-32IPLA 1 PZ-64IPLA 2 PZ-128IPLA 2 Table 2-7 Maximum Number of Package Installed Maximum Number of Package Installed Board (Power Factor) 19 inch with CD-CP00 19 inch without CD-CP00 4 x 19 inch CD-ETIA (2) 3 3 12 CD-PVAA (1) 5 6 23 CD-RTB (2) 2 2 8 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-12 Table 2-8 Terminal Power Factor Terminal Power Factor Total =< 80 Item Power Factor DTL-24D-1( ) TEL 0.8 DTL-8LD-1( ) TEL 0.8 BHA-L UNIT 2 ADA-L UNIT 2 APR-L UNIT 2 APR UNIT 3 BCH-L (BK) UNIT 2 PSA-L UNIT 1.2 8LK-L UNIT 0 DCL-60-1( ) CONSOLE 2 ITL-320C-1( ) TEL 6 ITL-24D-1( ) TEL 4 ITL-2E-1( ) TEL 4 ITL-6DE-1( )TEL 4 SLT(-28V) 0.8 SLT(-48V) 2 IP1WW-2PGDAD 2 IP1E-1SLTAD 5 ITL factors are calculated using the CD-ETIA blade Table 2-9 IP Terminal Power Chart Label Indication (Maximum Current with All Options) Maximum Current Without Options IP Terminal IEEE80 2.3af Class 48VDC 24VDC 48VDC 24VDC ITL-320C-1( ) TEL Class 3 160mA 7.7W 290mA 7.0W 111mA 5.3W 192mA 4.6W ITL-32D-1( ) TEL Class 2 130mA 6.2W 235mA 5.6W 90mA 4.3W 153mA 3.7W ITL-8LD-1( ) TEL Class 2 130mA 6.2W 235mA 5.6W 81mA 3.9W 137mA 3.3W ITL-24D-1( ) TEL Class 2 130mA 6.2W 235mA 5.6W 81mA 3.9W 137mA 3.3W ITL-12D-1( ) TEL Class 2 130mA 6.2W 235mA 5.6W 81mA 3.9W 137mA 3.3W ITL-24PA-1( ) TEL Class 2 130mA 6.2W 235mA 5.6W - 0.0W - 0.0W ITL-24PD-1( ) TEL Class 2 130mA 6.2W 235mA 5.6W - 0.0W - 0.0W ITL-24BT-1( ) TEL Class 2 130mA 6.2W 235mA 5.6W - 0.0W - 0.0W ITL-6DE-1( ) TEL Class 1 68mA 3.3W 122mA 2.9W 68mA 3.3W 122mA 2.9W ITL-2E-1( ) TEL Class 1 68mA 3.3W 122mA 2.9W 68mA 3.3W 122mA 2.9W Label Indication: IP Value/Sophisticated – Maximum watts when adding options or modular upgrades. IP Value – Maximum watts when ITL-12D-1( ) TEL is changed to ITL-8LD-1( ) TEL or ITL-24D-1( ) TEL. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

2-13 Table 2-10 IEEE802.af Class Specifications IEEE802.3af Minimum Maximum Class 4 - - Class 3 6.49W 12.95W Class 2 3.84W 6.49W Class 1 0.44W 3.84W Class 0 0.44W 12.95W CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-14 SECTION 5 SYSTEM REQUIREMENT AND SPECIFICATION 5.1 Cabling This section provides cabling requirements and specifications for various equipment used in the SV8100 system. Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable is a diagram of the chassis connected with each of the multiline terminals and single line telephones by a separate twisted 1-pair cable or 2-pair cable (only for Multiline Terminals). Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable Refer to the following tables for cabling requirements and specifications.  Table 2-11 DT300 Series Loop Resistance and Cable Length  Table 2-12DT700 Series Loop Resistance and Cable Length  Table 2-13 Dterm Series i or Dterm IP Terminal Loop Resistance and Cable Length  Table 2-14 Cable Connection Between the Analog Port and the Single Line Equipment  Table 2-15 Cabling Requirements CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

2-15 Table 2-11 DT300 Series Loop Resistance and Cable Length Terminal or Adapter By Twisted 1-Pair Cable (without AC Adapter) 24 AWG DTL-2E-1( ) (BK) TEL DTL-6DE-1( ) (BK) TEL DTL-8LD-1( ) (BK)TEL DTL-8LD-1( ) (WH) TEL DTL-12BT-1( ) (BK) TEL DTL-12PA-1( ) (BK) TEL DTL-12D-1( ) (BK)TEL DTL-12D-1( ) (WH) TEL DTL-24D-1( ) (BK) TEL DTL-24D-1( ) (WH) TEL DTL-32D-1( ) (BK)TEL DTL-32D-1( ) (WH) TEL DCL-60-1( ) Console* 1,969 ft (600m) *An AC Adapter is required. Table 2-12 DT700 Series Loop Resistance and Cable Length Terminal or Adapter Ethernet Cable ITL-2E-1( ) (BK) TEL ITL-6DE-1( ) (BK) TEL ITL-8LD-1( ) (BK) TEL ITL-8LD-1( ) (WH) TEL ITL-12BT-1( ) (BK) TEL ITL-12D-1( ) TEL ITL-12D-1( ) (WH) TEL ITL-12PA-1( ) (BK) TEL ITL-24D-1( ) (BK) TEL ITL-24D-1( ) (WH) TEL ITL-32D-1( ) (BK) TEL ITL-32D-1( ) (WH) TEL ITL-32OC-1( ) (BK) TEL Cat 5/Cat 6 Ethernet 328.1 ft (100m) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-16 Table 2-13 Dterm Series i or Dterm IP Terminal Loop Resistance and Cable Length Terminal or Adapter Maximum Loop Resistance (without AC Adapter) (Ohms) By Twisted 1-Pair Cable (without AC Adapter) 24 AWG By Twisted 2-Pair Cable (without AC Adapter) 24 AWG Maximum Loop Resistance (with AC Adapter) (Ohms) By Twisted 1-Pair Cable (with AC Adapter) 24 AWG By Twisted 2-Pair Cable (with AC Adapter) 24 AWG DTH-8-1TEL DTR-8-1 TEL 37 700 1400 107 2000 2000 DTH-8D-1TEL DTR-8D-1TEL 37 700 1400 107 2000 2000 DTH-16-1TEL DTR-16-1 TEL 35 660 1320 107 2000 2000 DTH-16D-1TEL DTR-16D-1TEL 35 660 1320 107 2000 2000 DTH-32D-1TEL DTR-32D-1TEL 26 500 1000 107 2000 2000 DTH-16LD-1 TEL 37 700 1400 107 2000 2000 DCR-60-1 Console* - - - 107 2000 2000 *An AC Adapter is required. Table 2-14 Cable Connection between the Analog Port and the Single Line Equipment Connected Equipment Cable Maximum Feet from Connected Equipment to Telephone ADA-L UNIT Twisted Pair 9.5 ft (2.89m) APR-L UNIT Twisted Pair 50 ft (15.24m) BCH-L (BK) UNIT NEC Provided 4 in (101.6mm) PSA-L UNIT Twisted Pair 1,700 ohms Analog Telephone (SLT, G3FAX, etc.) Twisted Pair 1500m with 24 AWG LCA Twisted Pair 1500m with 24 AWG Mixing digital and analog ports through the same 25-pair cable runs is not recommended. Table 2-15 Cabling Requirements Connected Equipment Cable Music on Hold and Background Music Sources Hi-Fi Shielded Audio Cable External Amplifier Hi-Fi Shielded Audio Cable ITL Cabling Cat 5 Straight Data Network Cable – 328.1 ft (100m) maximum distance. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

A dedicated 100VAC/120VAC/220VAC/230-240VAC 50/60 Hz circuit located within

seven feet of the chassis is required. A separate dedicated outlet for each chassis should be installed Double Pole/Neutral Fusing (Power supply fuses are located at both the L and N side). 5.2.1 Power Supply Specification Table 2-16 AC Power Supply: System Hardware Manual 2-17 110VAC 220VAC 230-240VAC Power Requirements 110 VAC @ 15A Controlling/Base Chassis 220VAC @ 15A Controlling/Base Chassis 230-240 VAC @ 15A Controlling/Base Chassis Power Consumption Base Chassis = 259VA 4 Chassis total = 1036VA Base chassis = 262VA, 4 Chassis total = 1048VA Base chassis = 276VA (1.15Ax240V), 4 Chassis total = 1104VA Input Voltage (Rated Voltage) 90VAC to 264VAC (100VAC/120VAC/220VAC/230-240VAC) Frequency 47Hz - 63Hz (Rated frequency: 50/60Hz) Phase and Wire Single Phase, 2 Line + PE Type Grounding Requirements No. 14 AWG copper wire Feeding Voltage Dterm/OPX/DID: -48V SLT: 25mA / -28V Output Power Base chassis = 130W, 4 chassis total = 520W Base chassis = 130W, 4 chassis total = 520W Base chassis = 130W, 4 chassis total = 520W AC Input I Base chassis = 2.35A, 4 chassis total =9.4A Base chassis = 1.19A, 4 chassis total = 4.76A Base chassis = 1.15A, 4 chassis total = 4.6A VA @ 110V/: VA @ 220V/ VA @ 230V-240V Base Chassis = 259VA 4 Chassis total = 1036VA Base Chassis = 262VA 4 Chassis total = 1048VA Base Chassis = 276VA (1.15Ax240V) 4 Chassis total =1104VA KWh @ AC Input I x 110V/1000/ KWh @ AC Input I x 220V/1000/ KWh @ AC Input I x 230-240V/1000 Base chassis = 0.259 KWh, 4 chassis total = 1.036 KWh Base chassis = 0.262 KWh, 4 chassis total = 1.048 KWh Base chassis = 0.276 KWh (1.15Ax240V) , 4 chassis total = 1.104 KWh CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-18  A dedicated outlet, separately fused and grounded for each chassis should be installed. Double Pole/Neutral Fusing (Power supply fuses are located at both the L and N side). 5.2.2 Power Supply Consumption Table 2-17 Power Consumption Chassis Voltage Maximum RMS Current Watts Used (Idle) Watts Used (Maximum) 110VAC 2.35A 220VAC 1.19A Basic Chassis – CD-CP00 Chassis 230-240VAC 1.15A 96 130 110VAC 4.7A 220VAC 2.38A Basic Chassis + Expansion Chassis 230-240VAC 2.3A 192 260 110VAC 7.05A 220VAC 3.57A Basic Chassis + 2 Expansion Chassis 230-240VAC 3.45A 288 390 110VAC 9.4A 220VAC 4.76A Basic Chassis + 3 Expansion Chassis 230-240VAC 4.6A 384 520 5.3 Environmental Conditions 5.3.1 Temperature and Humidity Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR  Operating Temperature: 0°C ~ 40°C  Recommended Long Term Temperature: -20°C ~ 60°C  Operating Humidity: 10 ~ 90% RH (non-condensing)  Recommended Long Term Humidity: 10 ~ 90% RH Blades - PZ-BS10, PZ-BS11, PZ-VM21, PZ-ME50, CD-8DLCA, CD-16DLCA, PZ-8DLCB  Operating Temperature: 0°C ~ 40°C  Recommended Long Term Temperature:-20°C ~ 60°C  Operating Humidity: 10 ~ 90% RH (non-condensing)  Recommended Long Term Humidity: 10 ~ 90% RH CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

2-19 Blades - CD-4LCA, PZ-4LCA, CD-8LCA, PZ-8LCE, CD-4COTA, PZ-4COTE, CD-PRTA  Operating Temperature: 0°C ~ 40°C  Recommended Long Term Temperature:-20°C ~ 60°C  Operating Humidity: 10 ~ 90% RH (non-condensing)  Recommended Long Term Humidity: 10 ~ 90% RH Door Box  Operating Temperature: -20°C ~ 60°C)  Operating Humidity: 20 ~ 80% RH (non-condensing) SV8100 Power Supply – MPS7101  Operating Temperature: 0°C ~ 40°C  Recommended Long Term Temperature:-40°C ~ 75°C)  Operating Humidity: 20 ~ 95% RH (non-condensing)  Recommended Long Term Humidity: 10 ~ 95% RH 5.4 Outside Line Type The following outside lines can be used with the UNIVERGE SV8100 system.  4-wire, E&M Tie Lines (Type I or V, Dial Pulse, or DTMF)  Digital Trunk T1/FT1/E1 (Loop Start, Ground Start, Tie Line (E&M), or DID Signaling)  ISDN-BRI Trunks  ISDN-PRI Trunks  VoIP Trunks (Internet Protocols) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-20 5.5 Transmission, Network and Control Specifications 5.5.1 Transmission  Data Length: From Multiline Terminal to CD-8DLCA: 23 bits From CD-8DLCA to Multiline Terminal: 23 bits  Data Transmission Rates: Between CD-8DLCA and Multiline Terminal: 184K bps (voice and signaling)  Scanning Time for each Multiline Terminal: 32 ms. 5.5.2 Network Time Division Multiplexing (TDM) allows transmission of data and voice simultaneously over one communications medium. The specifications that the UNIVERGE SV8100 system uses for switching, clock, data bus, and timeframe are shown below.  TDM Switching: PCM (A-Law)  TDM Clock: 2.048 MHz  TDM Data Bus: 8 bit  TDM Timeframe: 125 µs. 5.5.3 Control This section indicates the speed or capacity:  Control: Stored program with distributed processing  Central Processor: 32-bit microprocessor  Clock: 266 MHz  Interface Blade: 8- or 16-bit microprocessor  Optional Blades: 16- or 32-bit microprocessor  Multiline Terminal (TDM): 8-bit microprocessor  Multiline Terminal (IP): 32-bit microprocessor  IP Adapter: 32-bit microprocessor  Attendant Console: 4-bit microprocessor  IP1E-1SLTAD: 4-bit microprocessor CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Dial Pulse Address Signaling

Dial Pulse Address Signaling uses dial pulses (regular momentary interruptions) to signal the equipment. The following Dial Pulse specifications are used In the UNIVERGE SV8100 system.  Pulse Rate: 10 ± 0.5 pps/20 ± 1.0 pps  Percent Break: 60 ± 1.5%  Interdigit Interval: 0 pps/20 pps 770 ms. ~ 830 ms. 5.7.2 Dual-Tone Multifrequency (DTMF) Address Signaling DTMF signaling includes push button or Touchtone dialing. When a key on a telephone is pushed, two tones (one high frequency and one low frequency) are provided. In the UNIVERGE SV8100 system, the following DTMF specifications are used.  Frequencies: Two sinusoidal frequencies are provided, one from the high frequency group and one from the low frequency group.  Frequencies Deviation: Less than ±1.5%  Signal Level: Nominal level per frequency: -6 ~ -4 dBm Minimum level per frequency Low Group: -10 dBm High Group: -8 dBm Maximum level per frequency: 0 dBm  Rise Time: Within 5 ms.  Duration of Dual Frequency Signal: 110 ms. default/60 ms. Minimum Interdigital Time: 140 ms. default/45 ms. minimum System Hardware Manual 2-21 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-22 5.6.3 External Equipment Connection  Door Phone or TV Door Phone  External Speaker via amplifier  External music source for MOH and BGM  Tape recorder for voice recording via IP1WW-2PGDAD  Door Lock/Release or General Purpose Relay via IP1WW-2PGDAD  Printer for SMDR by LAN  PC by LAN 5.6.4 Music Source for Music on Hold via Chassis  Auxiliary Input: 0.6V PPS Signal Level  Input Impedance: 600 Ω 5.6.5 Music Source for Station Background Music via ACI  Auxiliary Input: 0.6V PPS Signal Level  Input Impedance: 600 Ω 5.6.6 External Paging (Audio)  Output Power: –10 dBm Signal Level  Output Impedance: 600 Ω  Relay Contact Rating: 500 mA, 24 Vdc 5.6.7 External Tone Ringer/Night Chime Output  Output Power: –10 dBm  Output Impedance: 600 Ω  Relay Contact Rating: 500 mA, 24 Vdc 5.6.8 SMDR  Female Connector (LAN) Standard DB-9 (straight) 5.6.9 PC Connection  Female Connector (LAN) Standard DB-9 (straight) 5.6.10 Relay Connection  All Relay Contact Ratings: 500 mA, 24Vdc CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

2-23 5.7 Battery Backup The UNIVERGE SV8100 system has battery backup functions for system backup and for memory backup. 5.7.1 System Backup (Optional) During a power failure, the system can be backed up using the CHS2U BATT MTG KIT for a backup time of 10 minutes or one of the CHS LARGE BATT SETs for a backup time ranging from 45~180 minutes. 5.7.2 Memory Backup The CD-CP00 Blade battery retains the Clock/Calender and Last Number Redial (LNR) buffers for each station when the CD-CP00 Blade encounters a power loss. With a fully charged battery, the settings are retained for about three years. The System Programmed memory (Customer Database) is stored in non-volatile Memory and can be erased only by a First Initialization. After power is restored, the system Blade returns to normal operation. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-24 5.8 Weights and Dimensions Table 2-18 SV8100 Weights and Dimensions shows the shipping weight, height, width and depth of each SV8100 digital multiline terminal, IP multiline terminal, Dterm, Series i multiline terminal, chassis, assorted blades and adapters. Table 2-18 SV8100 Weights and Dimensions Unit Shipping Weight Height Width Depth SV8100 CHS2U 278.7 oz (7.9 kg) 3.47 in (88 mm) 16.9 in (430 mm) 14.17 in (360 mm) CD-CP00 7.06 oz (0.2 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.09 in (180 mm) PZ-ME50 .353 oz (0.01 kg) 0.12 in (3 mm) 2.56 in (65 mm) 1.22 in (31 mm) CD-LTA 6.70 oz (0.19 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.09 in (180 mm) CHS LARGE BATT BOX 352.7 oz (10 kg) 23.23 in (590 mm) 17.72 in (450 mm) 10.43 in (265 mm) CHS LARGE BATT SET 194 oz (5.5 kg) 6.69 in (170 mm) 5.91 in (150 mm) 4.33 in (110mm) Common MPS7101 31.75 oz (0.9 kg) 2.36 in (60 mm) 7.08 in (180 mm) 6.10 in (155mm) PZ-BS10 2.29 oz (0.065 kg) 0.91 in (23 mm) 2.17 in (55 mm) 7.28 in (185 mm) PZ-BS11 1.975 oz (0.056 kg) 0.91 in (23 mm) 2.17 in (55 mm) 7.28 in (185 mm) PZ-VM21 1.76 oz (0.05 kg) 0.60 in (15 mm) 2.09 in (53 mm) 3.35 in (85 mm) PZ-32IPLA 1.76 oz (0.05 kg) 0.60 in (15 mm) 3.15 in (80 mm) 6.3 in (160 mm) PZ-64IPLA 1.76 oz (0.05 kg) 0.60 in (15 mm) 3.15 in (80 mm) 6.3 in (160 mm) PZ-128IPLA 1.76 oz (0.05 kg) 0.60 in (15 mm) 3.15 in (80 mm) 6.3 in (160 mm) CD-8DLCA 5.86 oz (0.167 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.09 in (180 mm) PZ-8DLCB 4.41 oz (0.125 kg) 0.60 in (15 mm) 4.72 in (120 mm) 5.12 in (130 mm) CD-16DLCA 7.831 oz (0.222 kg) 1.89 in (48 mm) 9.45 in (240 mm) 7.68 in (195 mm) CD-4COTA 6.35 oz (0.18 kg) 1.89 in (48 mm) 9.45 in (240 mm) 7.68 in (195 mm) PZ-4COTE 3.53 oz (0.10 kg) 1.89 in (48 mm) 9.45 in (240 mm) 5.12 in (130 mm) CD-4LCA 5.99 oz (0.17 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) PZ-4LCA 3.10 oz (0.09 kg) 0.60 oz (15 mm) 9.45 in (240 mm) 7.68 in (195 mm) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

2-25 Table 2-18 SV8100 Weights and Dimensions (Continued) Unit Shipping Weight Height Width Depth CD-8LCA 6.46 oz (0.183 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) PZ-8LCE 3.70 oz (0.105 kg) 0.60 oz (15 mm) 9.45 in (240 mm) 7.68 in (195 mm) CD-2BRIA 5.99 oz (0.17 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) PZ-2BRIA 4.02 oz (0.114 kg) 0.60 oz (15 mm) 4.72 in (120 mm) 7.68 in (195 mm) CD-PRTA 5.5 oz (0.156 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) CD-4ODTB 8.25 oz (0.234 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) CD-RTB 12.17 oz (0.345 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.68 in (195 mm) CD-VM00 7.76 oz (0.22 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) CD-PVAA 10.05 oz (0.285 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.68 in (195 mm) CD-ETIA 12.17 oz (0.345 kg) 0.98 in (25 mm) 5.71 in (145 mm) 7.68 in (195 mm) CD-4DIOPB 7.73 oz (0.219 kg) 0.98 in (25 mm) 9.45 in (240 mm) 7.68 in (195 mm) CHS BASE UNIT 21.87 oz (0.62 kg) 23.23 in (590 mm) 17.72 in (450 mm) 10.43 in (265 mm) CHS2U BLANK SLOT COVER KIT 1.76 oz (0.05 kg) 2.32 in (60 mm) 1.57 in (40 mm) 1.57 in (40 mm) CHS L BATT BOX RACK MOUNT BRACKET 352.7 oz (10 kg) 18.5 in (470 mm) 14.6 in (370 mm) 2.76 in (70 mm) CHS2U INT BATT SET 95.24 oz (2.7 kg) 4.33 in (110 mm) 2.76 in (70 mm) 3.15 in (80 mm) CHS2U RACK MOUNT KIT 17.6 oz (0.5 kg) 0.91 in (23 mm) 9.65 in (245 mm) 3.35 in (85 mm) CHS1U/2U WALL MOUNT KIT 35.27 oz (1 kg) 1.18 in (30 mm) 13.8 in (350 mm) 1.77 in (45 mm) CHS LARGE BATT BOX 458.6 oz (13 kg) 5.24 in (133 mm) 16.93 in (430 mm) 14.3 in (363 mm) CHS2U JOINT BRACKET KIT 7.06 oz (0.2 kg) 0.19 in (3 mm) 5.91 in (150 mm) 1.7 in (43 mm) CHS2U BATT MTG KIT 6 Slot 106 oz (3.0 kg) 2.95 in (75 mm) 4.45 in (113 mm) 4.13 in (105 mm) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-26 Table 2-18 SV8100 Weights and Dimensions (Continued) Unit Shipping Weight Height Width Depth Digital Multiline Terminal DTL-2E-1( ) (BK) TEL 35.27 oz (1.0 kg) 4.41 in (112 mm) 7.05 in (179 mm) 8.86 in (225 mm) DTL-6DE-1( ) (BK) TEL 38.8 oz (1.1 kg) 4.41 in (112 mm) 7.05 in (179 mm) 8.86 in (225 mm) DTL-8LD-1( ) (BK) TEL DTL-8LD-1( ) (WH) TEL 45.6 oz (1.3 kg) 4.41 in (112 mm) 7.05 in (179 mm) 10.39 in (225 mm) DTL-12BT-1( ) (BK) TEL 45.6 oz (1.3 kg) 4.29n (109 mm) 7.6 in (183.mm) 10.16 in (258 mm) DTL-12PA-1( ) (BK) TEL 45.6 oz (1.3 kg) 4.41 in (112 mm) 7.6 in (183.mm) 10.16 in (258 mm) DTL-12D-1( ) (BK) TEL DTL-12D-1( ) (WH) TEL 42.33 oz (1.2kg) 4.39 in (111.7 mm) 7.05 in (179.mm) 10.16 in (258 mm) DTL-24D-1( ) (BK) TEL DTL-24D-1( ) (WH) TEL 42.33 oz (1.2kg) 4.39 in (111.7 mm) 7.05 in (179.mm) 10.16 in (258 mm) DTL-32D-1( ) (BK) TEL DTL-32D-1( ) (WH) TEL 45.6 oz (1.3 kg) 4.39 in (111.7 mm) 8.1 in (205.8 mm) 10.16 in (258 mm) IP Multiline Terminal ITL-2E-1( ) (BK) TEL 35.27 oz (1.0 kg) 4.41 in (112 mm) 7.05 in (179 mm) 8.86 in (225 mm) ITL-6DE-1( ) (BK) TEL 38.8 oz (1.1 kg) 4.41 in (112 mm) 7.05 in (179 mm) 8.86 in (225 mm) ITL-8LD-1( ) (BK) TEL ITL-8LD-1( ) (WH) TEL 45.6 oz (1.3 kg) 4.41 in (112 mm) 7.05 in (179 mm) 10.39 in (225 mm) ITL-12BT-1( ) (BK) TEL 45.6 oz (1.3 kg) 4.29n (109 mm) 7.59 in (193.mm) 10.16 in (258 mm) ITL-12D-1( ) (BK) TEL ITL-12D-1( ) (WH) TEL 42.33 oz (1.2kg) 4.41 in (112 mm) 7.05 in (179.mm) 10.16 in (258 mm) ITL-12PA-1( ) (BK) TEL 45.6 oz (1.3 kg) 4.41 in (112 mm) 7.59 in (193.mm) 10.16 in (258 mm) ITL-24D-1( ) (BK) TEL ITL-24D-1( ) (WH) TEL 42.33 oz (1.2kg) 4.41 in (112 mm) 7.05 in (179.mm) 10.16 in (258 mm) ITL-32D-1( ) (BK) TEL ITL-32D-1( ) (WH) TEL 45.6 oz (1.3 kg) 4.41 in (112 mm) 8.1 in (205.8 mm) 10.16 in (258 mm) ITL-320C-1( ) (BK) TEL 56.44 oz (1.6 kg) 4.41 in (112 mm) 8.94 in (227 mm) 9.84 in (250 mm) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

2-27 Table 2-18 SV8100 Weights and Dimensions (Continued) Unit Shipping Weight Height Width Depth Optional 8LK-L (BK) UNIT 8LK-L (WH) UNIT 7.05 oz (0.2 kg) 1.77 in (45 mm) 1.15 in (29.3 mm) 8.82 in (224 mm) ADA-L UNIT 2.82 oz (0.08 kg) 0.98 in (25 mm) 2.56 in (65 mm) 3.23 in (82 mm) APR-L UNIT 5.29 oz (0.15 kg) 0.98 in (25 mm) 2.56 in (65 mm) 3.23 in (82 mm) BCH-L (BK) UNIT 5.29 oz (0.15 kg) 4.41 in (112 mm) 2.52 in (64 mm) 8.8 in (223 mm) BHA-L UNIT 3.53 oz (0.1 kg) 0.98 in (25 mm) 2.56 in (65 mm) 2.84 in (72 mm) IPLA-RP( ) UNIT 2.82 oz (0.08 kg) 0.98 in (25 mm) 2.24 in (57 mm) 3.94 in (100 mm) IP1WW-2PGDAD 12.4 oz (0.35 kg) 1.58 in (40 mm) 6.81 in (173 mm) 4.13 in (105 mm) DCL-60-1( ) (BK) CONSOLE DCL-60-1( ) (WH) CONSOLE 21.16 oz (0.6 kg) 3.23 in (82 mm) 5.39 in (137 mm) 8.82 in (224 mm) PSA-L (BK) UNIT PSA-L (WH) UNIT 10.58 oz (0.3 kg) 3.15 in (80 mm) 2.91 in (74 mm) 8.8 in (223 mm) DSS WM-L UNIT 1.41 oz (0.04 kg) 0.99 in (25.3 mm) 3.4 in (86.5 mm) 4.92 in (125 mm) WM-L UNIT 1.58 oz (0.045 kg) 0.996 in (25.3 mm) 3.996 in (101.5 mm) 4.92 in (125 mm) 1 Shipping weight includes the shipping carton. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

SV8100 System Specifications

2-28 - - NOTES - - CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-1 Chapter3; Installing the SV8100 Chassis SECTION 1 GENERAL INFORMATION This chapter contains information to help the technician install the chassis for the SV8100 system. The technician should be familiar with this section before installing any equipment. SECTION 2 INSTALLING THE CHASSIS The CHS2U chassis has six universal blade slots for legacy line/trunk blade (Single Line Telephone Interface, Digital Multiline Terminal Interface, Central Office Trunk, ISDN PRI Interface, etc.), In-skin Application Blades (In-skin UMS, In-Skin Router, etc.). It also houses the BUS Interface Blade, Power Supply Unit (PSU) and Cooling FAN. When the CD-CP00 blade is installed in the first 19” chassis, it is referred to as the controlling chassis. Additional chassis, referred to as expansion chassis, can be installed to increase the capacity of the system to meet the customer’s business needs. Each chassis (Expansion or Controlling), is powered by a MPS7101 power supply. The chassis can be wall mounted, floor mounted, stand mounted or rack mounted. The first part of this chapter describes the differing types of mounting options and the rest of this section describes how to install the chassis. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-2 Universal Slot for Legacy Line/Trunk blades and Application blades (six slots). When used as controlling chassis, the CD-CP00 is mounted in Slot1 (shown) Slot for PZ-BS10/PZ-BS11 blade –Connection with CHS2U chassis Power Switch Figure 3-1 CHS2S Chassis (Front View) 2.1 Wall Mounting the 19” Chassis When wall mounting the chassis, ensure the wall can support the weight of the chassis (55 lbs per system chassis ---- including blades, cords, power supply, etc.). The chassis is secured to the wall with a wall mount bracket. Ensure that enough space is available to allow the installation of additional expansion chassis. Figure 3-2 CHS2S Chassis (Rear View) AC Connector Fan Unit Internal Battery Mount (inside of cover) Battery Connector (inside of cover) Frame Ground (FG) Terminal CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-3 2.1.1 CHS2U Chassis Wall Mount Installation 1. Use the template shown in Figure 3-3 Wall Mount Spacing Guide (19” Chassis) for required spacing before drilling.  Plywood should first be installed on the wall where the chassis will be positioned. This allows secure anchoring of the screws which support the weight of the chassis.  Due to chassis weight, NEC recommends only a single CHS2U chassis per wall mount. Figure 3-3 Wall Mount Spacing Guide (19” Chassis) 2. Mark and drill the six holes required for a wall installation. 3. Align screw holes in wall mount brackets with drilled holes. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-4 4. Using six screws, secure the two wall mount brackets to the wall. Refer to Figure 3-4 Install Wall Mount Brackets with Screws for screw location. Figure 3-4 Install Wall Mount Brackets with Screws 5. Using four screws, secure the metal fittings on the Left and Right sides of the 19” chassis. Refer to Figure 3-5 Install Wall Mount Brackets with Screws on page 3-5 for screw location. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-5 Figure 3-5 Install Wall Mount Brackets with Screws CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-6 6. Align the metal fitting with the upper wall mount bracket. The lower metal fitting rests against the lower wall mount bracket. Secure the metal fitting and upper wall mount bracket with a single screw (see Figure 3-6 Secure Metal Fitting to Upper Wall Mount Bracket with a Screw). Figure 3-6 Secure Metal Fitting to Upper Wall Mount Bracket with Screws 7. Using two screws, secure the metal fitting to the lower wall mount bracket. Refer to Figure 3-7 Secure Metal Fitting to Lower Wall Mount Bracket with Screws on page 3-7 for screw location. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Figure 3-7 Secure Metal Fitting to Lower Wall Mount Bracket with Screws

8. Attach the supplied cable support bracket to either end of the lower wall mount bracket with a single screw (refer to Figure 3-8 Attach Cable Support Bracket with Screw on page 3-8). System Hardware Manual 3-7 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-8 Figure 3-8 Attach Cable Support Bracket with Screw 9. The cable support bracket can be installed any of the four corners of the 19” chassis (refer to Figure 3-9 Attach Cable Support Bracket with Screw). CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Figure 3-9 Attach Cable Support Bracket with Screw

10. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-33 for complete details on grounding the system. 11. Refer to 2.5 Installing the 19” Chassis on page 3-21 to continue installation of the chassis or, Chapter 4 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. System Hardware Manual 3-9 CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-10 2.2 Floor Mounting the 19” Chassis The CHS2U controlling and expansion chassis can be mounted on the floor using the CHS BASE UNIT and the CHS2U JOINT BRACKET KIT. 2.2.1 CHS2U Chassis Installation 1. Use the template shown in Figure 3-10 Floor Mount Spacing Guide for required spacing before drilling holes for 0.39” (10mm) anchor bolts (locally procured). Figure 3-10 Floor Mount Spacing Guide 2. Mark and drill the four holes required for installing the CHS BASE UNIT. 3. Using anchor bolts, secure the CHS BASE UNIT to the floor. Refer to Figure 3-11 Secure CHS BASE UNIT with Anchor Bolts on page 3-11 for screw location. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-11 Figure 3-11 Secure CHS BASE UNIT with Anchor Bolts 4. Install the five rubber feet to the bottom of the chassis. Figure 3-12 Install Rubber Feet 5. Position the chassis on top of the CHS BASE UNIT. 6. Secure the chassis to the CHS BASE UNIT using eight screws supplied with the CHS2U JOINT BRACKET KIT. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-12 Figure 3-13 Install CHS2U JOINT BRACKET KIT 7. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-33 for complete details on grounding the system. 8. Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue installation of the chassis or, Chapter 5 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. 2.2.2 Multiple CHS2U Chassis Installation Expansion chassis can be secured to the CHS BASE UNIT and will require an additional CHS2U JOINT BRACKET KIT per chassis. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-13 1. Install the five rubber feet to the bottom of each chassis. Figure 3-14 Install Rubber Feet 2. Using supplied screws in the CHS2U JOINT BRACKET KIT, attach metal brackets to both ends of the 19” chassis and the CHS BASE UNIT. Refer to Figure 3-15 Install Metal Brackets with Screws. Figure 3-15 Install Metal Brackets with Screws CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-14 3. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-33 for complete details on grounding the system. 4. Refer to 2.5 Installing the 19” Chassis on page 3-21 to continue installation of the chassis or, Chapter 4 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. 2.3 Stand Mounting the 19” Chassis A single or multiple chassis can be stand mounted. Controlling and Expansion chassis can be stand mounted using the CHS2U STAND KIT (K) and CHS2U STAND KIT (EXT). 2.3.1 CHS2U Chassis Installation 1. Using the supplied screws, assemble the CHS2U STAND KIT (K) and CHS2U STAND KIT (EXT) (refer to Figure 3-16 Assemble Stand Mount with Screws). Figure 3-16 Assemble Stand Mount with Screws 2. Secure the CHS2U chassis to the assembled CHS2U STAND KIT refer to Figure 3-17 Secure CHS2U Chassis to CHS2U STAND KIT with Screws on page 3-15. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-15 Figure 3-17 Secure CHS2U Chassis to CHS2U STAND KIT with Screws 3. Using supplied screws, secure the CHS2U STAND KIT to the floor (refer to Figure 3-18 Secure Stand Mount to Floor with Screws on page 3-16). To prevent possible damage to the 19” chassis due to falling, NEC recommends screws be installed in the stand mount brackets as soon as possible. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-16 Figure 3-18 Secure Stand Mount to Floor with Screws 4. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-33 for complete details on grounding the system. 5. Refer to 2.5 Installing the 19” Chassis on page 3-21 to continue installation of the chassis or, Chapter 4 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. 2.3.2 Multiple CHS2U Chassis Installation Expansion chassis (maximum of three) can be added to the CHS2U STAND KIT and will require an additional CHS2U STAND KIT (EXT) per chassis. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-17 1. Install the five rubber feet to the bottom of each chassis. 2. Each additional chassis will require CHS2U STAND KIT (EXT) to be installed (refer to Figure 3-20 Install Additional CHS2U STAND KIT (EXT)). Figure 3-19 Attach Rubber Feet to CHS2U Chassis Figure 3-20 Install Additional CHS2U STAND KIT (EXT) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-18 3. Metal brackets from the CHS2U JOINT BRACKET KITs will be required to secure the top end of the chassis with screws. See Figure 3-21 Install Additional CHS2U STAND KIT (EXT) on page 3-18. Figure 3-21 Install Additional CHS2U STAND KIT (EXT) 4. Using supplied screws, secure the CHS2U STAND KIT to the floor (refer to Figure 3-21 Install Additional CHS2U STAND KIT (EXT) on page 3-18). To prevent possible damage to the 19” chassis due to falling, NEC recommends screws be installed in the stand mount brackets as soon as possible. 5. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-33 for complete details on grounding the system. 6. Refer to 2.5 Installing the 19” Chassis on page 3-21 to continue installation of the chassis or, Chapter 4 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-19 2.4 Rack Mounting the 19” Chassis A single or multiple chassis can be rack mounted. Controlling and Expansion chassis can be racked mounted by stacking them horizontally.. 1. The 19” chassis requires two rack mount brackets per chassis for mounting. Each 19" chassis requires its own set of rack mount bracket(s). Refer to Figure 3-22 CHS2U Rack Mount Brackets. Stacking additional chassis (without rack mount brackets) on top of one rack mounted chassis is not recommended. Figure 3-22 CHS2U Rack Mount Bracket 2. Line up the Rack Mount Bracket(s) with the pre-drilled holes on each side of the 19” chassis. 3. Secure the brackets to the chassis using the supplied screws. Refer to Figure 3-23 Rack Mount Bracket Installed 19” CHS2U on page 3-20 for the 19” chassis. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-20 Repeat for additional chassis mounting. Figure 3-23 Rack Mount Bracket Installed 19”CHS2U 4. Carefully slide the chassis into desired location in the rack. Make sure the hooks on the mounting bracket are inserted into the back of the chassis, securing it in place. Note that the cabling is run through the front of the rack for ease of access. Each CHS2U chassis will require approximately 3.5” of height within the rack. 5. Secure the brackets to the rack using the screws supplied. Repeat for additional chassis mounting. Figure 3-24 Rack Mount 19”CHS2U CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-21 6. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis Grounding on page 3-33 for complete details on grounding the system. 7. Refer to 2.5 Installing the 19” Chassis on page 3-21 to continue installation of the chassis or, Chapter 4 paragraph 2.2 Installing an Extension or Trunk Blade on page 4-4 for installation of blades. 2.5 Installing the 19” Chassis There are two types of chassis; the controlling (with the CD-CP00 installed) and the expansion (that does not have the CD-CP00 blade installed). As discussed in other chapters, multiple chassis can be linked together to expand the port size of the system. 2.5.1 Unpacking the Equipment Inspect the equipment for any physical damage. If you are not sure about the function of a component, review the associated information within this manual. Contact your authorized NEC Sales Representative if you have additional questions. Note that the chassis does not initially contain any blades. Make sure you have appropriate tools for the job, including: a test set, a punch down tool, and a digital voltmeter. Ensure that you have a building plan showing common equipment, extensions, the Telco demarcation and earth ground location before you start installation. Be sure to properly plan your installation site and that you are familiar with the installation safety precautions. If you have not done that, please do so now. 2.5.2 Before Installation Before installing the chassis check the following:  Ensure that the MPS7101 (Power Supply Unit) is OFF and that that the power cord is disconnected from the AC outlet.  When installing the blades, do not touch the soldered surfaces as this may cause damage. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-22 2.5.3 Installing the 19” Controlling Chassis 1. Ensure the chassis is powered down. Do not remove or install this blade with the power on. 2. Align the CD-CP00 blade with the Slot 1 Guides of the Controlling Chassis. Figure 3-25 19"Controlling Chassis – Slot 1 Guides 3. Slide the CD-CP00 blade into the chassis until resistance (back plane) is felt. Figure 3-26 Installing the CD-CP00 Blade 4. Gently push until the blade seats. Tighten the two retaining screws on front of the blade. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-23 Figure 3-27 CD-CP00 Blade Installed 2.5.4 Installing Expansion Blade in the 19” Chassis (Optional) When adding additional chassis to the system to expand the capacity, a PZ-BS10 must be installed in the Controlling Chassis and a PZ-BS11 must be installed in all Expansion Chassis. This connection is required with any multiple-chassis setup. The PZ-BS10 connects the Controlling Chassis to the Expansion Chassis by connecting to a PZ-BS11, which is installed on each Expansion Chassis. These Expansion Interface Units allow the CPU to transmit/receive data as required to the additional chassis. The PZ-BS10 is installed in the Expansion Bay of the Controlling Chassis which is equipped with a CD-CP00 Blade. The PZ-BS11 is installed in the expansion slot of the Expansion Chassis, which does not have a CD-CP00 Blade. The EXIFU cable connects the Controlling Chassis and its PZ-BS10 interface to the second, third, and fourth PZ-BS11 interface. Use only the CAT 5 cables provided by NEC to make the connections between the Controlling and Expansion Chassis. The PZ-BS10 provides:  Communication Processor Interface for data handling through Communication Channel (24 slots maximum)  64 Channels for Telephony Resource (e.g., DTMF Tone Receiver, Call Progress Tone Detector, MFC Tone Receiver, Caller ID Receiver, Caller ID Signal Sender)  DSP Resource Management CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-24 2.5.4.1 Connector Pin-Out on the PZ-BS10/PZ-BS11 RJ-61 Cable Connector PZ-BS10 – CN2, CN3, CN4 PZ-BS11 – CN3 Pin No. Connection 1 HW_UP(+) 2 HW_UP(-) 3 HW_DWN(+) 4 FS(+) 5 FS(-) 6 HW_DWN(-) 7 CK8M(+) 8 CK8M(-) Table 3-1 PZ-BS10/PZ-BS11 Connector Pin-Out 2.5.4.2 Install the PZ-BS10 Expansion Base Blade in the CHS2U Controlling Chassis Do not remove or install this blade with the power on. 1. Ensure the chassis is powered down. 2. Locate the door positioned on the left end (expansion bay) of the Controlling Chassis. Figure 3-28 PZ-BS10 Expansion Bay in Controlling Chassis CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-25 3. From the left side of the chassis, pull cover outward to expose the expansion bay. Figure 3-29 Open Base Chassis Cover 4. Pull the cover toward you to remove. Cover must be removed prior to installation of PZ-BS10 blade. 5. Align the PZ-BS10 blade with the guides located in the expansion bay. Figure 3-30 PZ-BS10 Blade Guides CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-26 Figure 3-31 PZ-BS10 Components 6. Slide the PZ-BS10 blade into the chassis until resistance (back plane) is felt. Figure 3-32 PZ-BS10 Blade in Expansion Bay 7. Gently push until the blade seats and install the supplied retaining screw. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-27 8. Align the door tabs with hinges and reattach the cover. Figure 3-33 PZ-BS10 Blade Installed 9. Close the PZ-BS10 cover. Figure 3-34 PZ-BS10 Installed (Cover Closed) 2.5.4.3 Install the PZ-BS11 Expansion Blade in the CHS2U Expansion Chassis .For the Expansion Chassis to function, the PZ-BS10 blade must be installed in Controlling Chassis. Do not remove or install this blade with the power on. 1. Ensure the chassis is powered down. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-28 2. Locate the door positioned on the left end (expansion bay) of the Expansion Chassis. Figure 3-35 PZ-BS11 Expansion Bay in Expansion Chassis 3. From the left side of the chassis, pull cover outward to expose the expansion bay. Figure 3-36 Open Expansion Chassis Cover CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-29 4. Pull the cover toward you to remove.. Cover must be removed to install PZ-BS11 blade. 5. Align the PZ-BS11 blade with the guides located within the expansion bay. Figure 3-37 PZ-BS11 Blade Guides 6. Slide the PZ-BS11 blade into the chassis until resistance (back plane) is felt. Figure 3-38 PZ-BS11 Blade Guides in Expansion Chassis 7. Gently push until the blade seats and install the supplied retaining screw. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-30 8. Align the door tabs with hinges and reattach the cover. Figure 3-39 PZ-BS11 Blade Installed 9. Close the PZ-BS11 blade cover. Figure 3-40 PZ-BS11 Blade Installed (Cover Closed) CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-31 2.5.4.4 Connect the Controlling and Expansion Chassis Installment of the PZ-BS10 blade and PZ-BS11 blade(s) must be completed prior to installation of the provided (CAT 5) expansion cabling. Figure 3-41 PZ-BS11 Blade Installed (Cover Closed) 1. Ensure Controlling and Expansion chassis are powered down. 2. Using the NEC provided CAT5 straight-through cable(s), attach one end to each Expansion Chassis CN2 connector on the PZ-BS11 blade (see Figure 3-42 System Expansion Cabling on page 3-32. Attach the opposite end to the CN2, CN3 or CN4 connector on the PZ-BS10 of the Controlling Chassis. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-32 Figure 3-42 System Expansion cabling 3. Repeat for additional Expansion Chassis. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-33 2.5.5 Install 19” Chassis Grounding From the factory, the SG, ETH and PBXG grounds are located inside the chassis and are connected to the FG ground (frame ground) on the back of the chassis. Each chassis (CHS2U) in the system must be grounded separately using the procedure listed below. 1. Ensure each Chassis is powered down and unplugged. 2. Ground each chassis by connecting a 14 AWG wire from the FG lug on the back side of the chassis to an electrical service ground (such as a cold water pipe). Figure 3-43 Chassis Grounding Lug 2.5.6 Install 19” Chassis Grounding on Multiple Chassis (Optional) From the factory, the SG, ETH and PBXG grounds are located inside the chassis and are connected to the FG ground (frame ground) on the back of the chassis. Each chassis (CHS2U) in the system must be grounded separately using the procedure listed below. 1. Ensure all Controlling and Expansion Chassis are powered down and unplugged. 2. Ground each chassis by connecting a 14 AWG wire from the FG lug on the back side of the chassis to an electrical service ground (such as a cold water pipe). CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-34 Figure 3-44 19” Chassis Grounding Lug (Multiple-Chassis) 2.5.7 Install AC Power Cords 1. Locate the supplied AC power cord and attach to the AC Inlet located on the back of the Controlling Chassis. Figure 3-45 Install the AC Power Cord CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-35 2.5.8 Install AC Power Cords on Multiple-Chassis (Optional) 1. Locate the supplied AC power cords and attach to the AC Inlets located on the back of the Controlling and Expansion Chassis. AC Power Cord to AC Inlets Figure 3-46 Install 19” the AC Power Cords (Multiple-Chassis) 2.5.9 Install Additional Blades Refer to Chapter 4, 2.1 Installation and Safety Precautions on page 4-3. 2.5.10 Apply Power to the 19” Chassis Refer to Chapter 4, 2.6 Powering Up the SV8100 on page 4-8. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-36 SECTION 3 BATTERY CONNECTION There are two types of battery connection to provide battery life in the event of a power failure, the internal battery and an external battery with CHS LARGE BATT BOX. 3.1 Installing the Internal Batteries An internal battery source using two batteries can be installed using the CHS2U BATT MTG KIT (mounting kit) and CHS2U BATT CABLE INT (internal cabling). CHS2U BATT MTG KIT (Backup time = 10 Minutes/24 Terminals) 1. Ensure the chassis is powered down. Ensure the CHS2U chassis is powered OFF. 2. Disconnect AC power and grounding cable from rear of chassis. 3. Remove screws from battery access panel on rear of chassis. Refer to Figure 3-47 Removing Battery Access Panel. Figure 3-47 Removing Battery Access Panel CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-37 4. Remove access panel containing the fan. Refer to Figure 3-48 Removing Access Panel and Figure 3-49 Access Panel Removed. Figure 3-48 Removing Access Panel Figure 3-49 Access Panel Removed CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-38 5. Using tie wraps, secure CHS2U BATT CABLE INT in cable guide bracket (refer to Figure 3-50 Installing Cable Guide). Figure 3-50 Installing Cable Guide 6. With supplied screw, install cable guide in chassis (refer to Figure 3-51 Installing Cable Guide). Figure 3-51 Installing Cable Guide CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-39 7. Install two 2.3 AH-12V batteries (locally procured) into the CHS2U BATT MTG KIT (refer to Figure 3-52 Installing Two Batteries). The first battery must be installed on the left side, then slid to the right due to an installation tab on the mounting kit. Figure 3-52 Installing Two Batteries 8. Using the supplied screws, secure the brackets to the CHS2U BATT MTG KIT (refer to Figure 3-52 Installing Two Batteries on page 3-39). CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Installing the SV8100 Chassis

3-40 9. Connect the provided battery cables to the batteries (refer to Figure 3-53 Installing Battery Cable). Figure 3-53 Installing Battery Cable 10. Connect CHS2U BATT CABLE INT to battery connector (refer to Figure 3-54 Connecting CHS2U BATT CABLE INT). Figure 3-54 Connecting CHS2U BATT CABLE INT CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

System Hardware Manual

3-41 11. Install CHS2U BATT MTG KIT into CHS2U chassis and tighten the retaining screws (see Figure 3-55 Installing Battery Tray into CHS2U Chassis). Figure 3-55 Installing Battery Tray into CHS2U Chassis 12. Reinstall access panel containing the fan and secure with supplied screw (refer to Figure 3-56 Installing the Access Panel). Figure 3-56 Installing the Access Panel 13. Connect grounding and AC power cable. CHUYÊN CUNG CẤP TỔNG ĐÀI NEC http//vietpro.com.vn

Other Telephone Manuals