NEC SV-8100 System Hardware Manual
Text of the manual
Nothing contained in this manual shall be deemed to be, and this manual does not constitute, a
warranty of, or representation with respect to, any of the equipment covered. This manual is
subject to change without notice and NEC Infrontia has no obligation to provide any updates or
corrections to this manual. Further, NEC Infrontia also reserves the right, without prior notice, to
make changes in equipment design or components as it deems appropriate. No representation is
made that this manual is complete or accurate in all respects and NEC Infrontia shall not be
liable for any errors or omissions. In no event shall NEC Infrontia be liable for any incidental or
consequential damages in connection with the use of this manual. This document contains
proprietary information that is protected by copyright. All rights are reserved. No part of this
document may be photocopied or reproduced without prior written consent of NEC Infrontia.
©2008 by NEC Infrontia Corporation All Rights Reserved.
Printed in Japan
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Chapter 1; Introduction to SV8100
SECTION 1 GENERAL INFORMATION.........................................................................1-1
SECTION 2 EQUIPMENT LIST.....................................................................................1-5
Chapter 2; SV8100 System Specifications
SECTION 1 GENERAL INFORMATION.........................................................................2-1
SECTION 2 SYSTEM BLOCK DIAGRAM .....................................................................2-1
SECTION 3 MAXIMUM SYSTEM CAPACITIES.............................................................2-5
3.1 SYSTEM CONFIGULATION - SV8100..................................................................2-6
SECTION 4 POWER- BASED CALCULATOR CHART...........................................2-11
SECTION 5 SYSTEM REQUIREMENT AND SPECIFICATION .................................2-14
5.1 CABLING........................................................................................................2-14
5.2 POWER REQUIREMENTS.................................................................................2-17
5.2.1 POWER SUPPLY SPECIFICATION ..........................................................2-17
5.2.2 POWER SUPPLY CONSUMPTION ...........................................................2-18
5.3 ENVIRONMENTAL CONDITIONS ........................................................................2-18
5.3.1 TEMPERATURE AND HUMIDITY .............................................................2-18
5.4 OUTSIDE LINE TYPE .......................................................................................2-19
5.5 TRANSMISSION, NETWORK AND CONTROL SPECIFICATIONS..............................2-20
5.5.1 TRANSMISSION ..................................................................................2-20
5.5.2 NETWORK ..........................................................................................2-20
5.5.3 CONTROL ..........................................................................................2-20
5.6 DIALING SPECIFICATIONS................................................................................2-21
5.6.1 DIAL PULSE ADDRESS SIGNALING ........................................................2-21
5.6.2 DUAL TONE MULTIFREQUENCY(DTMF) ADDRESS SIGNALING ................2-21
5.6.3 EXTERNAL EQUIPMENT CONNECTION ...................................................2-22
5.6.4 MUSIC SOURCE FOR MUSIC ON HOLD VIA CHASSIS ...............................2-22
5.6.5 MUSIC SOURCE FOR STATION BACKGROUND MUSIC VIA ACI..................2-22
5.6.6 EXTERNAL PAGING (AUDIO) .................................................................2-22
5.6.7 EXTERNAL TONE RINGER/NIGHT CHIME OUTPUT ..................................2-22
5.6.8 SMDR................................................................................................2-22
5.6.9 PC CONNECTION ................................................................................2-22
5.6.10 RELAY CONNECTION............................................................................2-22
5.7 BATTERY BACKUP ..........................................................................................2-23
5.7.1 SYSTEM BACKUP(OPTIONAL) ...............................................................2-23
5.7.2 MEMORY BACKUP................................................................................2-23
5.8 WEIGHT AND DIMENSIONS ..............................................................................2-24
System Hardware Manual
I
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Chapter 3; Installing the SV8100 Chassis
SECTION 1 GENERAL INFORMATION..................................................................3-1
SECTION 2 INSTALLING THE CHASSIS...............................................................3-1
2.1 WALL MOUNT THE 19” CHASSIS........................................................................3-2
2.1.1 CHS2U CHASSIS WALL MOUNT INSTALLATION........................................3-3
2.2 FLOOR MOUNTING THE 19” CHASSIS...............................................................3-10
2.2.1 CHS2U CHASSIS INFORMATION...........................................................3-10
2.2.2 MULTIPLE CHS2U CHASSIS INSTALLATION ...........................................3-12
2.3 STAND MOUNTING THE 19” CHASSIS...............................................................3-14
2.3.1 CHS2U CHASSIS INFORMATION...........................................................3-14
2.3.2 MULTIPLE CHS2U CHASSIS INSTALLATION ...........................................3-16
2.4 RACK MOUNTING THE 19” CHASSIS.................................................................3-19
2.5 INSTALLING THE 19” CHASSIS .........................................................................3-21
2.5.1 UNPACKING THE EQUIPMENT................................................................3-21
2.5.2 BEFORE INSTALLATION.........................................................................3-21
2.5.3 INSTALLING THE 19” CONTROLLING CHASSIS.........................................3-22
2.5.4 INSTALLING EXPANSION BLADE IN THE 19” CHASSIS (OPTIONAL) ..........3-23
2.5.4.1 CONNECTOR PIN-OUT ON THE PZ-BS10/PZ-BS11....................3-24
2.5.4.2 INSTALL THE PZ-BS10 EXPANSION BASE BLADE IN THE CHS2U
CONTROLLING CHASSIS ..........................................................3-24
2.5.4.3 INSTALL THE PZ-BS11 EXPANSION BLADE IN THE CHS2U
EXPANSION CHASSIS................................................................3-27
2.5.4.4 CONNECT THE CONTROLLING AND EXPANSION CHASSIS .............3-31
2.5.5 INSTALLING 19” CHASSIS GROUNDING..................................................3-33
2.5.6 INSTALLING 19” CHASSIS GROUNDING ON MULTIPLE CHASSIS
(OPTIONAL).........................................................................................3-33
2.5.7 INSTALL AC POWER CORDS.................................................................3-34
2.5.8 INSTALL AC POWER CORDS ON MULTIPLE-CHASSIS (OPTIONAL)............3-35
2.5.9 INSTALL ADDITIONAL BLADES................................................................3-35
2.5.10 APPLY POWER TO THE 19” CHASSIS ...................................................3-35
SECTION 3 BATTERY CONNECTION.................................................................3-36
3.1 INSTALLING THE INTERNAL BATTERIES .............................................................3-36
3.2 INSTALLING THE EXTERNAL BATTERIES............................................................3-42
3.2.1 FLOOR MOUNTING THE CHS LARGE BATT BOX ................................3-42
3.2.2 BATTERY INSTALLATION........................................................................3-44
3.2.3 CHS LARGE BATT BOX TO CHS2U CONNECTION.............................3-48
3.2.4 CHS LARGE BATT BOX FUSE REPLACEMENT ...................................3-51
SECTION 4 REMOVE AND INSTALL COOLING FAN ............................................3-55
II
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
4.1 CHS2U CHASSIS...........................................................................................3-55
4.1.1 REMOVE COOLING FUN .......................................................................3-55
4.1.2 INSTALL COOLING FUN.........................................................................3-57
Chapter 4; Installing the SV8100 Blades
SECTION 1 GENERAL INFORMATION..................................................................4-1
1.1 SLOT LOCATIONS .............................................................................................4-1
SECTION 2 INSTALLATION.................................................................................4-3
2.1 INSTALLATION AND SAFETY PRECAUTIONS .........................................................4-3
2.2 INSTALLING AN EXTENSION OR TRUNK BLADE ....................................................4-4
2.2.1 INSTALLING THE BLADE ..........................................................................4-4
2.2.2 ORDER OF INSTALLING EXTENSION BLADES ............................................4-4
2.2.3 ORDER OF INSTALLING TRUNK BLADES ...................................................4-5
2.2.3.1 INSTALLING CD-4COTA, CD-4DIOPB, CD-4ODTB OR
CD-2BRIA BLADES....................................................................4-5
2.2.3.2 INSTALLING CD-PRTA (T1/E1/PRI) BLADES................................4-5
2.3 REMOVE AN EXTENSION OR TRUNK BLADE........................................................4-6
2.4 UNINSTALLING A BLADE SLOT THROUGH SOFTWARE ..........................................4-6
2.5 BLADE CAPACITIES...........................................................................................4-6
2.6 POWERING UP THE SV8100.............................................................................4-8
2.6.1 PERFORMING A COLD START..................................................................4-8
2.6.2 PERFORMING A HOT START....................................................................4-9
2.6.3 RESETING THE SYSTEM .........................................................................4-9
2.6.3.1 INITIAL PROGRAMMING................................................................4-9
2.6.3.2 PORT DEFAULTS .......................................................................4-10
2.6.3.3 SETTING UP EXTENSION CIRCUIT TYPES....................................4-10
2.6.3.4 SAVING YOUR CONFIGURATION ................................................. 4-11
2.6.3.5 BACKING UP/RESTORING A DATABASE ....................................... 4-11
2.6.4 PERFORMING A SOFTWARE UPGRADE...................................................4-12
SECTION 3 COMMON CONTROL BLADE...........................................................4-14
3.1 CD-CP00 (SV8100 CENTRAL PROCESSING UNIT)..........................................4-14
3.1.1 DESCRIPTION......................................................................................4-15
3.1.2 INSTALLATION......................................................................................4-17
3.1.3 SWITCH SETTINGS...............................................................................4-19
3.1.4 LED INDICATION..................................................................................4-20
3.1.5 CONNECTORS .....................................................................................4-22
3.2 PZ-ME50 (MEMORY EXPANSION DAUGHTER BOARD)......................................4-24
System Hardware Manual
II
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
3.3 PZ-VM21 (VOICE MAIL DAUGHTER BOARD)....................................................4-27
3.3.1 DESCRIPTION......................................................................................4-27
3.3.2 INSTALLATION......................................................................................4-28
3.3.3 SWITCH SETTINGS...............................................................................4-29
3.4 PZ-32IPLA/PZ-64IPLA/PZ-128IPLA (VOICE OVER IP DAUGHTER BOARDS)...4-30
3.4.1 DESCRIPTION......................................................................................4-30
3.4.2 INSTALLATION......................................................................................4-31
3.4.3 SWITCH SETTINGS...............................................................................4-31
3.4.4 LED INDICATIONS................................................................................4-32
3.4.5 CONNECTORS .....................................................................................4-33
SECTION 4 STATION BLADES..........................................................................4-35
4.1 CD-8DLCA/CD-16DLCA (DIGITAL STATION INTERFACE) ...............................4-35
4.1.1 DESCRIPTION......................................................................................4-36
4.1.2 INSTALLATION......................................................................................4-37
4.1.3 LED INDICATIONS................................................................................4-37
4.1.4 CONNECTORS .....................................................................................4-38
4.2 PZ-8DLCB (DIGITAL STATION DAUGHTER BOARD) .........................................4-40
4.2.1 DESCRIPTION......................................................................................4-40
4.2.2 INSTALLATION......................................................................................4-41
4.2.3 PZ-8DLCB DAUGHTER BOARD CABLE CONNECTION............................4-41
4.3 CD-4LCA/ CD-8LCA (4-PORT/8-PORT SINGLE LINE INTERFACE) ...................4-42
4.3.1 DESCRIPTION......................................................................................4-43
4.3.2 INSTALLATION......................................................................................4-44
4.3.3 LED INDICATIONS................................................................................4-45
4.3.4 CONNECTORS .....................................................................................4-46
4.4 PZ-4LCA/PZ-8LCE (4-PORT/8-PORT SLT DAUGHTER BOARDS)....................4-47
4.4.1 DESCRIPTION......................................................................................4-49
4.4.2 INSTALLATION......................................................................................4-50
4.4.3 CONNECTORS .....................................................................................4-51
4.5 CD-LTA (DTERM/SLT COMBINATION) ............................................................4-52
4.5.1 DESCRIPTION......................................................................................4-52
4.5.2 INSTALLATION......................................................................................4-53
4.5.3 LED INDICATIONS................................................................................4-54
4.5.4 CONNECTORS .....................................................................................4-55
SECTION 5 TRUNK BLADES............................................................................4-56
IV
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
5.1 CD-4COTA (4 LOOP START INTERFACE)........................................................4-56
5.1.1 DESCRIPTION......................................................................................4-56
5.1.2 INSTALLATION......................................................................................4-58
5.1.3 LED INDICATIONS................................................................................4-58
5.1.4 CONNECTORS .....................................................................................4-59
5.2 PZ-4COTE (4 LOOP START INTERFACE DAUGHTER BOARD) ...........................4-60
5.2.1 DESCRIPTION......................................................................................4-60
5.2.2 INSTALLATION......................................................................................4-62
5.2.3 CONNECTORS .....................................................................................4-62
5.3 CD-2BRIA (2 BASIC RATE INTERFACE) ..........................................................4-63
5.3.1 DESCRIPTION......................................................................................4-63
5.3.2 INSTALLATION......................................................................................4-64
5.3.3 LED INDICATIONS................................................................................4-65
5.3.4 CONNECTORS .....................................................................................4-66
5.4 PZ-2BRIA (2 BASIC RATE INTERFACE DAUGHTER BOARD)..............................4-67
5.4.1 DESCRIPTION......................................................................................4-68
5.4.2 INSTALLATION......................................................................................4-69
5.4.3 CONNECTORS .....................................................................................4-70
5.5 CD-4DIOPB (DID/OPX INTERFACE)..............................................................4-71
5.5.1 DESCRIPTION......................................................................................4-71
5.5.2 INSTALLATION......................................................................................4-72
5.5.3 LED INDICATIONS................................................................................4-72
5.5.4 CONNECTORS .....................................................................................4-73
5.6 CD-PRTA (PRI/T1/E1 INTERFACE)............................................................4-74
5.6.1 DESCRIPTION......................................................................................4-74
5.6.2 INSTALLATION......................................................................................4-75
5.6.3 LED INDICATIONS................................................................................4-77
5.6.4 CONNECTORS .....................................................................................4-79
5.7 CD-4ODTB (4-PORT TIE LINE INTERFACE BLADE)..........................................4-81
5.7.1 DESCRIPTION......................................................................................4-81
5.7.2 INSTALLATION......................................................................................4-82
5.7.3 LED INDICATIONS................................................................................4-83
5.7.4 CONNECTORS .....................................................................................4-84
5.7.5 CONNECTIONS ....................................................................................4-85
SECTION 6 OPTIONAL BLADES.......................................................................4-87
6.1 CD-VM00 (VOICE MAIL AND SERVER)............................................................4-87
6.1.1 DESCRIPTION......................................................................................4-87
System Hardware Manual
V
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
6.1.3 LED INDICATIONS................................................................................4-89
6.1.3.1 ACTIVE LED - GREEN ..............................................................4-89
6.1.3.2 BUSY LED - RED......................................................................4-90
6.1.3.3 APPLICATION LED - RED/GREEN (DUAL COLOR) ......................4-90
6.1.3.4 COMPACTFLASH CARD ACTIVITY LED - RED ............................4-90
6.1.4 CONNECTORS .....................................................................................4-90
6.1.4.1 RS-232 INTERFACE .................................................................4-90
6.1.4.2 DB9 TO 6-PIN MODULAR RS-232 ADAPTER...............................4-91
6.1.4.3 RS-232 SERIAL CABLE (DTE)...................................................4-91
6.1.4.4 RS-232 SERIAL CABLE (DCE) ..................................................4-92
6.1.4.5 USB INTERFACE.......................................................................4-92
6.1.4.6 VGA DISPLAY INTERFACE .........................................................4-92
6.1.4.7 10 BASE-T/100 BASE-TX ETHERNET INTERFACE .....................4-92
6.2 CD-PVAA (CONFERENCE BRIDGE) ................................................................4-94
6.2.1 DESCRIPTION......................................................................................4-94
6.2.2 INSTALLATION......................................................................................4-95
6.2.3 SWITCH SETTINGS...............................................................................4-95
6.2.4 LED INDICATIONS................................................................................4-96
6.2.5 CONNECTORS .....................................................................................4-96
6.3 CD-RTB (4-PORT ROUTER)...........................................................................4-97
6.3.1 DESCRIPTION......................................................................................4-97
6.3.2 INSTALLATION......................................................................................4-99
6.3.3 LED INDICATIONS................................................................................4-99
6.4 CD-ETIA (GIGABIT POE SWITCH) ................................................................4-100
6.4.1 DESCRIPTION....................................................................................4-100
6.4.2 INSTALLATION....................................................................................4-101
6.4.2.1 STACKING ARCHITECTURE .....................................................4-101
6.4.2.2 CD-CP00 IP ADDRESS ASSIGNMENT ......................................4-101
6.4.2.3 GROUP FORMATION................................................................4-102
6.4.2.4 PORT NUMBER DETERMINATION..............................................4-102
6.4.2.5 UNMANAGED SWITCH FUNCTIONS ...........................................4-103
6.4.3 LED INDICATIONS..............................................................................4-103
6.4.4 CONNECTORS ...................................................................................4-103
SECTION 7 CABLING AND MDF CONNECTION ..............................................4-104
7.1 CONNECTION REQUIREMENTS ......................................................................4-104
7.2 CABLING PRECAUTIONS ...............................................................................4-104
VI
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
7.3 WIRING BETWEEN THE CHASSIS AND THE MDF .............................................4-104
7.3.1 CHASSIS CABLES ..............................................................................4-104
7.3.2 OUTSIDE LINES .................................................................................4-108
Chapter 5; Installing DT300/DT700 Series (DTL/ITL) Digital and IP Multiline
Terminals
SECTION 1 GENERAL INFORMATION..................................................................5-1
SECTION 2 DT300 SERIES DIGITAL MULTILINE TERMINALS ...............................5-7
2.1 DIGITAL MULTILINE TERMINALS .........................................................................5-7
2.1.1 DTL-2E-1( ) (BK) TEL..........................................................................5-7
2.1.2 DTL-6DE-1( ) (BK) TEL .......................................................................5-8
2.1.3 DTL-8LD-1( ) (BK) TEL/ DTL-8LD-1( ) (WH) TEL ................................5-8
2.1.4 DTL-12BT-1( ) (BK) TEL......................................................................5-9
2.1.5 DTL-12D-1( ) (BK) TEL/ DTL-12D-1( ) (WH) TEL ..............................5-10
2.1.6 DTL-12PA-1( ) (BK) TEL.................................................................... 5-11
2.1.7 DTL-24D-1( ) (BK) TEL/ DTL-24D-1( ) (WH) TEL ..............................5-12
2.1.8 DTL-32D-1( ) (BK) TEL/ DTL-32D-1( ) (WH) TEL ..............................5-13
SECTION 3 DT700 SERIES IP MULTILINE TERMINALS......................................5-15
3.1 IP MULTILINE TERMINALS ...............................................................................5-15
3.1.1 ITL-2E-1( ) (BK) TEL..........................................................................5-15
3.1.2 ITL-6DE-1( ) (BK) TEL.......................................................................5-16
3.1.3 ITL-8LD-1( ) (BK) TEL/ ITL-8LD-1( ) (WH) TEL .................................5-16
3.1.4 ITL-12D-1( ) (BK) TEL/ ITL-12D-1( ) (WH) TEL .................................5-17
3.1.5 ITL-12PA-1( ) (BK) TEL .....................................................................5-18
3.1.6 ITL-24D-1( ) (BK) TEL/ ITL-24D-1( ) (WH) TEL .................................5-19
3.1.7 ITL-32D-1( ) (BK) TEL/ ITL-32D-1( ) (WH) TEL .................................5-20
3.1.8 ITL-320C-1( ) (BK) TEL .....................................................................5-21
SECTION 4 INSTALL MULTILINE TERMINALS ....................................................5-23
4.1 CONNECTING THE DT300 SERIES MULTILINE TERMINAL TO THE SYSTEM ..........5-23
4.2 APPLYING POWER TO THE DT700 MULTILINE TERMINALS.................................5-24
4.3 CONNECTING THE IP MULTILINE TERMINAL TO THE NETWORK AND PC ..............5-25
4.4 ADJUSTING THE LCD ON THE MULTILINE TERMINAL..........................................5-26
4.5 INSTALLING LINE KEY KIT (12LK-L KIT) ..........................................................5-27
4.5.1 INSTALLING THE 12LK-L KIT................................................................5-27
4.5.2 CONFIGURING THE DIGITAL TELEPHONE FOR THE CORRECT NUMBER
OF LINE KEYS......................................................................................5-32
System Hardware Manual
VI
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
4.5.3 CONFIGURING THE IP TELEPHONE FOR THE CORRECT NUMBER
OF LINE KEYS......................................................................................5-32
4.6 INSTALLING THE DIRECTORY CARD ON THE MULTILINE TERMINAL......................5-34
4.7 REMOVAL AND REPLACEMENT OF THE NUMBERED KEYPADL .............................5-35
4.7.1 REMOVING THE NUMBERED KEYPAD.....................................................5-36
4.7.2 INSTALLING THE NUMBERED KEYPAD ....................................................5-37
4.8 REMOVAL AND REPLACEMENT OF THE BS ( )-L KIT (TEN KEY KIT).....................5-38
4.8.1 REMOVE THE BS ( ) – L KIT ................................................................5-38
4.8.2 INSTALL THE BS ( ) - KIT .....................................................................5-39
4.8.3 CONFIGUREING THE DIGITAL TELEPHONE FOR THE TEN KEY KIT ...........5-41
4.8.4 CONFIGUREING THE IP TELEPHONE FOR THE NUMBERED KEY ..............5-41
4.9 ADJUSTING THE HEIGHT ON THE MULTILINE TERMINAL .....................................5-43
4.10 REMOVING OR INSTALLING THE TILT LEGS ON THE MULTILINE TERMINAL..........5-44
4.10.1 REMOVE TILT LEGS ..........................................................................5-44
4.10.2 INSTALL TILT LEGS.............................................................................5-45
4.11 WALL MOUNTING THE MULTILINE TERMINAL...................................................5-46
4.11.1 WALL MOUNTING A MULTILINE TERMINAL USING THE BASE PLATE.........5-46
4.11.1.1 ADJUSTING THE HANGER HOOK...............................................5-46
4.11.1.2 WALL MOUNTING THE MULTILINE TERMINAL..............................5-47
4.11.1.3 REMOVING THE MULTILINE TERMINAL FROM THE WALL
MOUNTED BASE PLATE...........................................................5-49
4.11.1.4 WALL MOUNTING THE BASE ON A SWITCH BOX .........................5-50
SECTION 5 MULTILINE TERMINALS OPTIONAL EQUIPMENT ..............................5-51
5.1 DT300/DT700 SERIES TERMINAL OPTIONS ....................................................5-51
5.2 DT300/DT700 SERIES OPTIONAL TERMINAL EQUIPMENT ................................5-52
5.2.1 8LK-L (BK) UNIT/8LK-L (WH) UNIT .................................................5-52
5.2.1.1 INSTALLING THE 8LK-L UNIT ...................................................5-52
5.2.2 8LKD (LD)-L (BK) UNIT/8LKD (LD)-L (WH) UNIT..............................5-54
5.2.2.1 INSTALLING THE 8LKD(LD)-L UNIT ..........................................5-55
5.2.3 8LKI (LD)-L (BK) UNIT/8LKI (LD)-L (WH) UNIT.................................5-58
5.2.3.1 INSTALLING THE 8LKI(LD)-L UNIT ...........................................5-59
5.2.4 DCL-60-1( ) (BK) CONSOLE/DCL-60-1( ) (WH) CONSOLE ............5-62
5.2.4.1 INSTALLING THE DCL-60-1 CONSOLE .....................................5-63
5.2.5 LCD (BL)-L (BK) UNIT/LCD (BL)-L (WH) UNIT ................................5-67
5.2.6 PANEL( )-L UNIT ...............................................................................5-68
5.2.7 WM-L UNIT........................................................................................5-69
5.2.7.1 MOUNT MULTILINE TERMINAL ON WALL USING WM-L UNIT.........5-69
VIII
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
5.2.7.2 MOUNT MULTILINE TERMINAL ON WALL PLATE USING WM-L UNIT5-73
5.2.8 DSS WM-L UNIT ...............................................................................5-77
5.2.8.1 MOUNT DCL-60-1 CONSOLE ON WALL USING DSS WM-L UNIT 5-77
5.2.8.2 MOUNT DCL-60-1 CONSOLE ON WALL PLATE USING
DSS WM-L UNIT ....................................................................5-78
SECTION 6 BLUETOOTH CORDLESS HANDSET ................................................5-80
6.1 BLUETOOTH CORDLESS HANDSET (BCH) INTERFACE ......................................5-80
6.2 SELECTING A LOCATION..................................................................................5-81
6.3 CONTROLS AND INDICATORS...........................................................................5-82
6.4 INSTALLING THE BLUETOOTH CORDLESS HANDSET ..........................................5-84
6.4.1 INSTALLING THE BLUETOOTH HANDSET CRADLE...........................5-84
6.4.2 WALL MOUNTING THE BLUETOOTH CRADLE ......................................5-90
6.4.3 REMOVE AND REPLACE HANDSET BATTERY ..........................................5-93
SECTION 7 BLUETOOTH HUB ADAPTER ..........................................................5-94
7.1 BLUETOOTH HUB ADAPTER (BHA) FEATURES .................................................5-94
7.1.1 INSTALLING THE BHA-L UNIT..............................................................5-94
7.1.2 PAIRING A BLUETOOTH DEVICE AND MULTILINE TRMINAL
(BLUETOOTH INSTALLED) .....................................................................5-96
7.1.2.1 ACCESSING THE BLUETOOTH DEVICE SETUP SCREEN ................5-96
7.1.2.2 ENTERING A PIN CODE .............................................................5-96
7.1.2.3 PAIRING....................................................................................5-96
7.1.2.4 CONNECTING THE PAIRED DEVICE .............................................5-97
7.1.2.5 UNPAIRING ...............................................................................5-97
7.1.2.6 VISIBILITY SETTING ...................................................................5-97
7.1.2.7 BT INFORMATION ......................................................................5-98
SECTION 8 SINGLE LINE TELEPHONE .............................................................5-99
8.1 INSTALLING THE IP1E-1SLTAD ......................................................................5-99
8.2 WALL MOUNTING THE IP1E-1SLTAD............................................................5-100
Chapter 6; Installing SV8100 Optional Equipment
SECTION 1 GENERAL INFORMATION..................................................................6-1
SECTION 2 IP1WW-2PGDAD..........................................................................6-1
2.1 USING A IP1WW-2PGDAD..............................................................................6-1
2.2 LED INDICATION ..............................................................................................6-2
2.3 SETTING UP IP1WW-2PGDAD CONNECTIONS .................................................6-2
SECTION 3 BACKGROUND MUSIC ...................................................................6-11
3.1 INSTALLING BACKGROUND MUSIC ................................................................... 6-11
System Hardware Manual
IX
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SECTION 4 DOOR BOX ............................................................................................6-12
4.1 INSTALLING A DOOR BOX ................................................................................6-12
SECTION 5 EXTERNAL PAGING .......................................................................6-16
5.1 EXTERNAL PAGE ............................................................................................6-16
5.2 INSTALLING AN EXTERNAL PAGE SYSTEM.........................................................6-16
SECTION 6 EXTERNAL PAGING AND DOOR BOX/PAGE RELAYS........................6-18
6.1 EXTERNAL PAGE RELAYS................................................................................6-18
6.2 DOOR BOX /EXTERNAL PAGE RELAY CONTACTS ..............................................6-19
6.2.1 CONNECTING A CONTACT RELAY DEVICE TO A DOOR BOX
/EXTERNAL PAGE RELAY......................................................................6-19
SECTION 7 EXTERNAL RECORDING SYSTEM/EXTERNAL RINGER ....................6-20
7.1 EXTERNAL RECORDING SYSTEM OR EXTERNAL RINGER...................................6-20
7.2 INSTALLING AN EXTERNAL RECORDING SYSTEM OR EXTERNAL RINGER ............6-21
7.3 PROGRAMMING..............................................................................................6-21
SECTION 8 MUSIC SOURCES .........................................................................6-25
8.1 MUSIC ON HOLD ............................................................................................6-25
8.2 INSTALLING EXTERNAL MUSIC ON HOLD ..........................................................6-25
SECTION 9 TELEPHONE LABELING .................................................................6-28
9.1 DESI PRINTER SHEETS..................................................................................6-28
9.1.1 REMOVING THE FACEPLATE..................................................................6-28
9.1.2 REPLACING THE FACEPLATE.................................................................6-28
SECTION 10 TELEPHONE ADAPTERS ..............................................................6-29
10.1 USING ADAPTERS ........................................................................................6-29
10.2 IN-LINE POWER ADAPTER (ILPA-R)...............................................................6-30
10.2.1 CONDITIONS......................................................................................6-30
10.2.2 INSTALLATIONS..................................................................................6-31
10.3 ADA-L UNIT ...............................................................................................6-33
10.3.1 ADA-L UNIT SWITCH SETTINGS ........................................................6-34
10.3.2 INSTALLING THE ADA-L UNIT ............................................................6-36
10.3.3 ADA-L UNIT CONNCTION..................................................................6-38
10.3.3.1 ADA-L UNIT CONNECTION FOR RECORDING ONLY ..................6-38
10.3.3.2 ADA-L UNIT CONNECTION FOR SENDING RECORDED CALLS
TO THE TELEPHONE ..............................................................6-39
10.4 APR-L UNIT ...............................................................................................6-39
10.4.1 APR-L UNIT SWITCH SETTINGS ........................................................6-40
10.4.2 INSTALLING THE APR-L UNIT ............................................................6-40
10.5 PSA-L (BK) UNIT / PSA-L (WH) UNIT........................................................6-43
X
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
10.5.1 INSTALLING THE PSA-L ADAPTER.......................................................6-44
10.5.2 USING THE PSA-L ADAPTER ..............................................................6-51
SECTION 11 POWER FAILURE TELEPHONES....................................................6-52
11.1 POWER FAILURE ..........................................................................................6-52
11.2 CONNECTOR PIN-OUTS ON COIU BLADE FOR POWER FAILURE CIRCUITS.......6-53
11.3 INSTALLING THE POWER FAILURE TELEPHONES..............................................6-53
System Hardware Manual
XI
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
R-1
Regulatory
BATTERY DISPOSAL
The UNIVERGE SV8100 system includes the batteries listed below. When disposing of these
batteries, Chassis, and/or Blades, you must comply with applicable federal and state regulations
regarding proper disposal procedures.
Unit Name
Type of Battery
Quantity
CD-CP00
Lithium
1
CT-12 Headset Cordless
Ni MH
1
DTH-4R-2
Ni MH
1
DTL-8R-1
Ni MH
1
DTR-1HM-1 TEL
Lithium
1
DTR-1R-2
Nickel-Cadmium
1
DTR-4R-2 TEL
Nickel-Cadmium
1
DTU-4R-1 TEL
Lead Acid
1
C124 (SIP DECT Wireless)
Ni MH
1
CHS LARGE BATT SET
Sealed Lead
1
Headset Cordless II
Ni MH
1
Internal Batteries
Sealed Lead
1
Bluetooth® Cordless Handset
Lithium-ion
1
Table R-1 Battery Types and Quantities for Chassis and Blades
The UNIVERGE SV8100 CD-CP00 provides memory backup for approximately three years. The
Lithium battery should be replaced every two years.
IMPORTANT SAFEGUARDS FOR BATTERY DISPOSAL
DO NOT PLACE USED BATTERIES IN YOUR REGULAR TRASH! THE PRODUCT YOU
PURCHASED CONTAINS LITHIUM, NICKEL-CADMIUM OR SEALED LEAD BATTERIES.
LITHIUM, NICKEL-CADMIUM OR SEALED LEAD BATTERIES MUST BE COLLECTED, RECYCLED,
OR DISPOSED OF IN AN ENVIRONMENTALLY SOUND MANNER.
The incineration, landfilling or mixing of nickel-cadmium or sealed lead batteries with the municipal
solid waste stream is PROHIBITED BY LAW in most areas. Contact your local solid waste
management officials for other information regarding the environmentally sound collection, recycling,
and disposal of the battery.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Nickel-Cadmium (or sealed lead) batteries must be returned to a federal or state approved
nickel-cadmium (or sealed lead) battery recycler. This may be where the batteries were originally sold
or a local seller of automotive batteries. Contact your local waste management officials for other
information regarding the environmentally sound collection, recycling and disposal of the battery
contained in this product.
The packaging for the UNIVERGE SV8100 system contains the following labels regarding proper
disposal.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
EUROPEAN UNION INFORMATION
Notice to the user
The system described in this manual is intended to be connected to analog and digital networks and
supports a wide range of peripheral equipment. The following interfaces are available for connection
to public analog and digital telecommunication networks:
TBR3 ISDN basic rate interface
TBR4 ISDN primary rate interface
ES203-021 Analogue interface
To take advantage of all features of this system and the connected equipment, the country or network
specific features should match the supported features of the system. For an overview of the
supported features, refer to the detailed documentation that comes with this system, contact your
local supplier.
Declaration of conformityHereby, “NEC Infrontia”, declares that the SV8100 is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC.
Electromagnetic Compatibility
For the SV8100 system the following warning is applicable:
Warning
This is a class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
System Hardware Manual
R-3
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
PRODUCT DISPOSAL INFORMATION
For Countries in the European Union
The symbol depicted here has been affixed to your product in order to inform you that electrical and
electronic products should not be disposed of as municipal waste.
Electrical and electronic products including the cables, plugs and
accessories should be disposed of separately in order to allow proper
treatment, recovery and recycling. These products should be taken to a
designated facility where the best available treatment, recovery and
recycling techniques are available. Separate disposal has significant
advantages: valuable materials can be re-used and it prevents the
dispersion of unwanted substances into the municipal waste stream.
This contributes to the protection of human health and the environment.
Please be informed that a fine may be imposed for illegal disposal of
electrical and electronic products via the general municipal waste
stream.
In order to facilitate separate disposal and environmentally sound
recycling arrangements have been made for local collection and recycling. In case your electrical and
electronic products need to be disposed of please refer to your supplier or the contractual agreements
that your company has made upon acquisition of these products.
Battery information
Defective or exhausted batteries should never be disposed of as municipal waste. Return old
batteries to the battery supplier, a licensed battery dealer or a designated collection facility. Do not
incinerate batteries. This product uses Lithium batteries. Do not use any other type.
For an overview of the location of batteries used in these systems, the battery replacement or removal
instructions please refer to the UNIVERGE SV8100 System Hardware Manual.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
1-1
Chapter1; Introduction to SV8100
SECTION 1
GENERAL INFORMATION
The SV8100 is a full-featured IP based communications system providing a rich
feature set of existing system, with pure Voice over IP (VoIP) communications,
across corporate Local and Wide Area Networks (LAN and WAN).
The DT700 series telephones provide a converged infrastructure at the desktop,
with a 10Base-T/100Base-TX connection to the LAN and built-in hub for a PC
connection to the telephone itself. The system can provide peer-to-peer
connections between the DT700 series telephones with voice compression,
offering existing IP telephone features with an enhanced user interface. On the
WAN side, the system can provide peer-to-peer connections over IP networks with
the voice compression, on CCIS over IP or Remote Unit over IP.
The SV8100 can provide legacy line/trunk interfaces to support the existing Time
Division Multiplexing (TDM) based infrastructure, such as analog telephones, digital
telephones (DT300 series), analog networks and digital networks (T1/E1, ISDN,
etc.).
The new compact 19” chassis provides 111 total ports (80 digital terminals) and can
be expanded, using three additional 19” chassis, for a maximum of 444 ports (368
digital terminals). Through IP connection and four additional 19” chassis, the
system can be expanded to a maximum of 512 ports for SV8100 (refer to Table 2-2
SV8100 Maximum System Capacities – Trunks/Ports/Channels on page 2-5).
Communications between legacy stations/trunks and DT700 series telephones/IP
networks are made using a VoIP daughter board, which converts packet-based
voice data to TDM-based voice data, and vice versa. Both peer-to-peer
connections and TDM-based connections are controlled by the CPU blade. The
CPU incorporates a built-in Device Registration Server (DRS) and a single interface
point of IP connection to IP telephone, PCPro and OAI / ACD servers. Figure 1-1
shows a simplified view of SV8100 system connectivity.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Introduction to SV8100
1-2
(via TCP/IP)
SP310 Softphone
Figure 1-1 Simplified SV8100 System Connectivity
Highlights of the UNIVERGE SV8100 are as follows:
Pure IP System capable TDM configuration
The SV8100 supports both pure IP switching (peer-to-peer connections) and Time
Division Switching. The pure IP switching is provided for communications between
DT700 series telephones and for CCIS / Remote Unit connections with other
SV8100. On the other hand, the TDM switching is provided for communications
between legacy stations/trunks. Connection between IP network and legacy
network is made via VoIP daughter board on the CPU blade, which converts
packet-based voice data to TDM-based voice data, and vice versa.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
1-3
Powerful CPU Blade with Built-in Functionalities
The CPU blade of SV8100 is a heart of pure IP connections and TDM-based
connections. The CPU blade employs a 32 bit microprocessor. With this processing
power and DSP technology, it integrates the following functions on one board.
Some of these functions are managed with software licenses.
DTMF receivers
Caller ID receivers
Caller ID senders
MF senders / receivers
10/100 Ethernet Port
2 Control Relays
MOH Input Port
Paging Output Port
In-Mail (VMDB)
VoIP
In addition, by means of advanced LSI technology, size of the CPU blade is
minimized, O&M NIC port (10/100M) is built in and VoIPDB which has VoIP NIC
port (Gigabit Ethernet) is mountable without additional slots in the chassis. The
O&M NIC port is linked with LAN/WAN for inter-work with PCPro, SMDR, OAI
server, and the VoIP NIC port is linked with LAN/WAN for control signaling and
voice signaling (RTP) for DT700 series.
High Density Legacy Line/Trunk Blades
Major legacy line/trunk blades used in SV8100 are provided with blade + daughter
board architecture. When the blade is mounted only in an initial supply, line/trunk
interfaces can be easily expanded by adding the daughter board. The maximum
number of ports for the line/trunk blades is 8/16 ports with daughter blade,
respectively. This allows the physical system size to be compact.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Introduction to SV8100
1-4
Universal Blade Slot (19” Chassis)
A 19” Chassis is used for legacy line/trunk blades. One 19” Chassis provides six
universal slots and one expansion slot. Also, the universal slots can be used for
special application blades without complicated limitation. This makes easy
quotation and installation.
Easy Installation (Front Cabling and Enhanced O&M Tool)
Cable connectors (RJ-45 or RJ-61) are located on the front panel of each chassis
and blade. This increases efficiency of the cabling work. Also, PCPro provides an
enhanced user interface. A Quick Setup tool provides easy setup (system data
programming) for a basic system configuration in shorter time.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
1-5
SECTION 2
EQUIPMENT LIST
The following tables list all equipment for the SV8100 systems.
Table 1-1 Chassis Equipment List
Equipment Name
Equipment Description
Remarks
CHS2U
19” Chassis (6-slot) with Power Supply
- AC Power Cable
- Blank Slot Cover
(5pcs.)
- Bus Slot Cover
(1pc)
MPS7101
Power Supply Unit for CHS2U
install into CHS2U
Table 1-2 Chassis Installation Equipment List
Equipment Name
Equipment Description
Remarks
CHS BASE UNIT
Floor Mount Kit for CHS2U
CHS2U BLANK SLOT COVER
KIT
Blank Slot Cover for CHS2U(1pc)
CHS BLANK SLOT COVER
KIT (BUS)
Blank Slot Cover for Bus slot(1pc)
CHS2U JOINT BRACKET KIT
Joint Bracket set to fix between upper and
lower CHS2U and/or CHS BASE UNIT
CHS2U RACK MOUNT KIT
19 inch Rack Mount Bracket for CHS2U
CHS1U/2U WALL MOUNT KIT
Wall Mount Set for CHS2U
CHS2U FAN BOX SET
FAN BOX for CHS2U
install into CHS2U
CHS2U STAND KIT (K)
Stand Mount Kit for CHS2U
CHS2U STAND KIT (EXT)
Stand Mount Kit for CHS2U (expansion parts)
Table 1-3 Battery Mount Equipment List
Equipment Name
Equipment Description
Remarks
CHS LARGE BATT BOX
Long Term Battery Box for CHS2U Chassis
(including following cables)
Cable between batteries – 9.06in/230mm
Fuse Unit to Batteries – 18.11in/460mm
Cable
from
chassis
to
battery
box
–
81.1in/2060mm
CHS2U BATT MTG KIT
Short term internal battery mount kit for
CHS2U, Backup time – 10 minutes
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Introduction to SV8100
1-6
Table 1-4 Blade Equipment List
Equipment
Name
Abbreviations
Equipment Description
Remarks
CD-CP00
CPU
Main Processor Blade including main
software
PZ-BS10
BUS0
Bus Unit for System Expansion (for Main
Chassis)
PZ-BS11
BUS1
Bus Unit for System Expansion (for
Expansion Chassis) with Cable
PZ-VM21
VMDB
Embedded VRS/VM Daughter Board with
V34 Analog Modem
PZ-32IPLA
VoIPDB
32-channel VOIP on CCPU
PZ-64IPLA
VoIPDB
64-channel VOIP on CCPU
PZ-128IPLA
VoIPDB
128-channel VOIP on CCPU
CD-8DLCA
DLC
8-port Digital Station Interface
PZ-8DLCB
DLCDB
8-port
Digital
Station
Interface
on
CD-8DLCA
CD-16DLCA
DLC
16-port Digital Station Interface
CD-4COTA
COT
4-port Loop Start Analog Trunks Interface
PZ-4COTE
COTDB
4-port Loop Start Analog Trunks Interface
on CD-4COTA, CD-LTA/LTB
CD-4LCA
LC
4-port Analog Terminal Interface
PZ-4LCA
LCDB
4-port Analog Terminal Interface on
CD-4LCA and CD-8LCA
CD-8LCA
LC
8-port Analog Terminal Interface
PZ-8LCE
LCDB
8-port Analog Terminal Interface on
CD-4LCA and CD-8LCA
CD-2BRIA
BRT
2 Basic Rate Interface
PZ-2BRIA
BRTDB
2 Basic Rate Interface on CD-2BRIA
CD-PRTA
PRT
1 PRI/T1/E1 INTERFACE
CD-4DIOPB
DIOP
4 port Analog DID/OPX Interface
CD-4ODTB
ODT
4-port Analog E&M Tie Line Interface
CD-RTB
RTB
In-Skin Router
CD-VM00
VM00
In-skin VM/UMS
CD-ETIA
GSWU
In-skin PoE Gigabit Switch Unit
PZ-ME50
MEM
Memory
Expansion
including
main
software on CD-CP00
CD-LTA
LTA
8
Digital
Station/2
Analog
Terminal
Interface
CD-PVAA
CNF
Conference Bridge
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
1-7
Table 1-5 Optional Equipment List
Equipment Name
Equipment Description
Remarks
IP1WW-2PGDAD
2 ports External Paging / Doorphone / Audio
Adapter
IP1E-1SLTAD
Analog Terminal Adapter for Digital Terminal
Port
DP-D-1A
Doorphone Box
AKS VRS OT
Compact Flash for Inmail
AKS VRS-VM OT
Compact Flash for Inmail
AKS UM-2G OT
CF Card for VM/UMS (2GB: 125h Rec.)
AKS UM-8G OT
CF Card for VM/UMS (8GB: 550h Rec.)
Table 1-6 Cable Equipment List
Equipment Name
Equipment Description
Remarks
CHS2U BATT CA INT
CHS2U Battery Cable set for Internal
Battery 2U Chassis
Cable A – 18.9in/480mm
Cable B – 3.15in/80mm
Table 1-7 Digital Multi Terminal (DT300 Series) Equipment List
Equipment Name
Equipment Description
Remarks
DTL-2E-1( ) (BK) TEL
Economy
Digital
2-button
Telephone
(No-Display)
DTL-6DE-1( ) (BK) TEL
Economy Digital 6-button Display Telephone
DTL-12D-1( ) (BK) TEL
DTL-12D-1( ) (WH) TEL
Value Digital 12-button Display Telephone
DTL-24D-1( ) (BK) TEL
DTL-24D-1( ) (WH) TEL
Value Digital 24-button Display Telephone
DTL-32D-1( ) (BK) TEL
Value Digital 32-button Display Telephone
DTL-12BT-1( ) (BK) TEL
12-button Display type Digital Terminal with
Bluetooth Cordless Handset
DTL-12PA-1( ) (BK) TEL
Value Digital 12-button Telephone with Power
Failure Adapter
DTL-8LD-1( ) (BK) TEL
DTL-8LD-1( ) (WH) TEL
Value Digital 8-button Telephone (DESI-less)
DCL-60-1( ) (BK) CONSOLE
DCL-60-1( ) (WH) CONSOLE
60-button Direct Station Selection (DSS)
Console
8LK-L( ) (BK) UNIT
8LK-L( ) (WH) UNIT
8-button Line Key Unit
8LKD (LD)-L (BK) UNIT
8LKD (LD)-L (WH) UNIT
DESI-less 8-button Line Key Unit/LCD Unit for
Digital Telephone
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Introduction to SV8100
1-8
Table 1-8 IP Multi Terminal (DT700 Series) Equipment List
Equipment Name
Equipment Description
Remarks
ITL-2E-1( ) (BK) TEL
Value IP 12-button Telephone with Power
Failure Adapter
ITL-6DE-1( ) (BK) TEL
Value IP 6-button Display Telephone
ITL-8LD-1( ) (BK) TEL
ITL-8LD-1( ) (WH) TEL
Value IP 8 Line Key Display Telephone
Value IP Telephone: DESI-less
ITL-12D-1( ) (BK) TEL
ITL-12D-1( ) (WH) TEL
Value IP 12 Line Key Display Telephone
ITL-24D-1( ) (BK) TEL
ITL-24D-1( ) (WH) TEL
Value IP 24 Line Key Display Telephone
ITL-32D-1( ) (BK) TEL
Value IP 32 Line Key Display Telephone
ITL-12PA-1( ) (BK) TEL
Value IP 12-button Telephone with Power
Failure Adapter
ITL-12BT-1( ) (BK) TEL
12-button Display type IP Terminal with
Bluetooth Cordless Handset
ITL-320C-1( ) (BK) TEL
Sophisticated Telephone
8LKI (LD)-L (BK) UNIT
8LKI (LD)-L (WH) UNIT
DESI-less LK/LCD Unit for IP Terminals
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
1-9
Table 1-9 DT300/DT700 Series Optional Equipment List
Equipment Name
Equipment Description
Remarks
APR-L( ) UNIT
Analog Terminal Adapter with Ringer (DT300
Only)
ADA-L( ) UNIT
Recording Jack Adapter
ILPA-R( ) UNIT
In-Line Power Adapter for IP Terminal
PSA-L( )(BK) UNIT
PSA-L( ) (WH) UNIT
Power Failure Transfer cradle
BCH-L( ) (BK) UNIT
Bluetooth Cordless Handset with cradle
BHA-L( ) UNIT
Bluetooth HUB Adapter
12LK-L (BK) KIT
12LK-L (WH) KIT
Additional 12 keys for 12D / 12PA / 12BT TEL
LCD (BL)-L (BK) UNIT
LCD (BL)-L (WH) UNIT
Backlit LCD Unit used only for DT300 Series
WM-L UNIT
Wall Mount kit for Terminal with Bottom
Adapter
DSS WM-L UNIT
Wall Mount Unit for DSS Console in case
terminal is using WM-L UNIT
DESI ITL/DTL-2E
(25 PKG)
DESI Sheet for Economy 2-button Telephone
(2 Labels per Sheet)
DESI ITL/DTL-6DE
(25 PKG)
DESI Sheet for Economy 6-button Display
Telephone (2 Labels per Sheet)
DESI ITL/DTL-12D
(25 PKG)
DESI Sheet for Value 12-button Display
Telephone (2 Labels per Sheet)
DESI ITL/DTL-8LK
(25 PKG)
DESI Sheet for 8-button Line Key (2 Labels
per Sheet)
DESI DCL-60
(25 PKG)
DESI Sheet for 60DSS (1 Label per Sheet)
DESI ITL/DTL-SIDE
(25 PKG)
DESI Sheet for Clear Side Panel (Left and
Right Label each Sheet)
DESI ITL/DTL-SIDE-LCDV
(25 PKG)
DESI Sheet for Value Telephone LCD (Clear
Side)
DESI ITL/DTL-SIDE-LCDS
(25 PKG)
DESI Sheet for Sophisticated Telephone LCD
(Clear Side)
DESI ITL/DTL Directory Card
Directory Card
DESI ITL/DTL-24D
(25 PKG)
DESI Sheet for Value 24-button Display
Telephone (2 Labels per Sheet)
Panel (Red-Base)-L UNIT
Color Side Panel for Base 2E/6DE TEL
Panel (Red-VLCD)-L UNIT
Color Side Panel for Value Telephone LCD
(12D/24D/32D/8LD/12PA/12BT TEL)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Introduction to SV8100
1-10
Table 1-9 DT300/DT700 Series Optional Equipment List (Continued)
Equipment Name
Equipment Description
Remarks
Panel (Red-SLCD)-L UNIT
Color Side Panel for Sophisticated Telephone
LCD (320C TEL)
Panel (Blue-Base)-L UNIT
Color Side Panel for 2E/6DE TEL
Panel (Blue-VLCD)-L UNIT
Color Side Panel for Value Telephone LCD
(12D/24D/32D/8LD/12PA/12BT TEL)
Panel (Blue-SLCD)-L UNIT
Color Side Panel for Sophisticated Telephone
LCD (320C TEL)
Panel (Wood-Base)-L UNIT
Color Side Panel for 2E/6DE TEL
Panel (Wood-VLCD)-L UNIT
Color Side Panel for Value Telephone LCD
(12D/24D/32D/8LD/12PA/12BT TEL)
Panel (Wood-SLCD)-L UNIT
Color Side Panel for Sophisticated Telephone
LCD (320C TEL)
Panel( Logo-Base)-L UNIT
Color Side Panel for all terminal (terminal
base only)
Panel (Clear-Base)-L UNIT
Color Side Panel for 2E/6DE TEL
Panel (Clear-VLCD)-L UNIT
Color Side Panel for Value Telephone LCD
(12D/24D/32D/8LD/12PA/12BT TEL)
Panel (Clear-SLCD)-L UNIT
Color Side Panel for Sophisticated Telephone
LCD (320C TEL)
LKPANEL(12BTN)-L(M-Blue)
UNIT
Color LK panel(12button) for Value(Metallic
Blue)
LKPANEL(12BTN)-L(GUNMET
A) UNIT
Color LK panel(12button) for
Value(GunMetallic)
LKPANEL(12BTN)-L(L-Green-
M) UNIT
Color LK panel(12button) for
Value(LimeGreen Metallic)
LKPANEL(12BTN)-L(Orange-M
) UNIT
Color LK panel(12button) for Value(Orange
Metallic)
LKPANEL(12BTN)-L(D-Brown-
M) UNIT
Color LK panel(12button) for
Value(DarkBrown Metallic
LKPANEL(24BTN)-L(M-Blue)
UNIT
Color LK panel(12button) for Value(Metallic
Blue)
LKPANEL(24BTN)-L(GUNMET
A) UNIT
Color LK panel(12button) for
Value(GunMetallic)
LKPANEL(24BTN)-L(L-Green-
M) UNIT
Color LK panel(12button) for
Value(LimeGreen Metallic)
LKPANEL(24BTN)-L(Orange-M
) UNIT
Color LK panel(12button) for Value(Orange
Metallic)
LKPANEL(24BTN)-L(D-Brown-
M) UNIT
Color LK panel(12button) for
Value(DarkBrown Metallic)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
1-11
Table 1-9 DT300/DT700 Series Optional Equipment List (Continued
VAL DIRECTORY CARD
UNIT(L)
Directory Card Holder for Value Telephone
ECO DIRECTORY CARD
UNIT(L)
Directory Card Holder for Economy Telephone
Table 1-10 License List
Equipment Name
Equipment Description
Remarks
LK-SYS-UNLIMT PORT-LIC
Unlimited port license in case more than 256
ports
License (Capacity)
LK-SYS-1ST-CTI1-LIC
1st Party CTI (over Ethernet) license (require
per client)
LK-SYS-3RD-CTI-CLIENT-LIC
3rd Party CTI license
License (CTI)
LK-SYS-ACD-CLIENT1-LIC
ACD Client license (require per client)
LK-SYS-ACD-PEVENT-LIC
ACD P-Event for MIS license
License (ACD)
LK-SYS-IP-TRUNK1-LIC
IP Tunk (SIP / H323) license
LK-SYS-IP-TERMINAL-1-LIC
IP Terminal (SIP-MLT / Softphone) license
LK-SYS-IP-TERMINAL-SIP1-LI
C
IP Terminal (SIP-MLT / Softphone / SIP SLT /
3rd Party) license
License (IP)
LK-SYS-NET LINK1-LIC
NetLink license (require per remote node)
LK-SYS-KCCIS-IP-LIC
K-CCIS over IP license (require per channel)
LK-SYS-FEATURE-NETWORK
NG-LIC
AspireNet over IP license
License
(Networking)
LK-SYS-HM-LIC
Hotel/Motel (including PMS) license
LK-SYS-OAI-LIC
OAI Activation license
License
(Application I/F)
LKS-VM-LANGUAGE1-LIC
Embedded VRS/VM Multi-Language license
License (Embedded
VRS/VM)
LKS-DESKTOP
SUITE-SOFTPHONE1-LIC
SP310 (Softphone) license
LKS-DESKTOP
SUITE-ENHANCE PKG1-LIC
Enhancement package (Presence, White
Board, File TRFR, IM) license
LK-DESKTOP SUITE-PC
ASSISTANT1-LIC
PC Assistant (Basic) license
LK-DESKTOP SUITE-PC
ATTENDANT1-LIC
PC Attendant (Superior) license
License (Desktop
Application)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Introduction to SV8100
1-12
Table 1-10 License List (Continued)
Equipment Name
Equipment Description
Remarks
LKS-UMS-PORT2 LITE-LIC
UMS Lite Mail port (2 ports) license
LKS-UMS-PORT4 LITE-LIC
UMS Lite Mail port (4 ports) license
LKS-UMS-PORT8 LITE-LIC
UMS Lite Mail port (8 ports) license
LKS-UMS-PORT16 LITE-LIC
UMS Lite Mail port (16 ports) license
LKS-UMS-PORT2 LITE UPG
KIT-LIC
2-Ports LITE Upgrade Kit license
LKS-UMS UPG FM LITE TO
FULL-LIC
Upgrade license from LITE Mail to FULL UMS
LKS-UMS-PORT4 -LIC
UMS port (4 ports) license
LKS-UMS-PORT8 -LIC
UMS port (8 ports) license
LKS-UMS-PORT16 -LIC
UMS port (16 ports) license
LKS-UMS-CLIENT1-LIC
UMS Client (view appli) license (1 client)
LKS-UMS-CLIENT4-LIC
UMS Client (view appli) license (4 clients)
LKS-UMS-CLIENT8-LIC
UMS Client (view appli) license (8 clients)
LKS-UMS-CLIENT16-LIC
UMS Client (view appli) license (16 clients)
LKS-UMS-CLIENT32-LIC
UMS Client (view appli) license (32 clients)
LKS-UMS
VIDEO
MAIL
CLIENT1-LIC
Video Mail Client license (1 client)
LKS-UMS
VIDEO
MAIL
CLIENT5-LIC
Video Mail Client license (5 clients)
LKS-UMS-FAX-LIC
UMS Fax port license
LKS-UMS-TTS-PORT-LIC
UMS TTS port license
LKS-UMS-LANGUAGE1-LIC
UMS Multi-Language license
LKS-UMS-HOTEL-PMS-LIC
UMS Hospitality / PMS license
LKS-UMS-HOTEL-LANGUAG
E-LIC
UMS Hospitality Language license
LKS-UMS-AMIS-PLUS-LIC
UMS Amis/Plus Net license
LKS-UMS-TTS-LANGUAGE-LI
C
UMS TTS Language license
LKS-UMS-MAIL-MANAGER-LI
C
UMS Mail Manager license
License (In-Skin
UMS)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
2-1
Chapter2; SV8100 System Specifications
SECTION 1 GENERAL INFORMATION
This chapter provides detailed specifications for the SV8100 system technician.
The technician should review this information carefully before installing the system.
SECTION 2 SYSTEM BLOCK DIAGRAM
Figure 2-1 SV8100 System Block Diagram on Page 2-4 shows the Blades that can
be installed in the chassis and the number of channels supported when the Blade is
installed. Table 2-1 List of Abbreviations lists abbreviations used in the diagram.
Table 2-1 List of Abbreviations
Abbreviation
Description
ACD
Automatic Call Distribution
ADA
Ancillary Devise Adapter
APR
Analog Port Adapter (with ringer)
AUX IN/OUT
BGM/MOH Port (on CD-CP00)
BCH
Bluetooth Cordless Handset
BHA
Bluetooth Hub Adapter
BRI
Basic Rate Interface
BRIDB
Expansion Basic Rate Interface Blade on BRI
BRT
Basic Rate Interface Blade/ISDN Terminal Interface Blade
BUS0
BUS Interface Blade (For Control Chassis)
BUS1
BUS Interface Blade (For Expansion Chassis)
CCT
CCIS Interface Blade
CF
Compact Flash
CFT
Conference Trunk (on CD-CP00)
CNF
Conference Bridge Blade (PVA)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-2
Table 2-1 List of Abbreviations (Continued)
Abbreviation
Description
COT
Central Office Trunk (Loop and Ground Start Interface)
COTDB
Expansion Loop and Ground Start Interface Blade on COT
CPU
Central Processing Unit
DID
Direct Inward Dialing
DIOP
DID/OPX Blade
DLC
Digital Multiline Terminal Interface Blade
DLCB
Expansion Digital Multiline Terminal Interface Blade on DLC
DRS
Device Registration Server (on CPU)
DSS
Direct Station Selection Console
DTI
Digital Trunk Interface
DTG
Digital Tone Generator (on CPU)
E1
E-carrier system ( European Digital Transmission Format)
ETHERNET
Ethernet Port (on CPU)
FT1
Fractional T1
GSWU
Power over Ethernet Gigabit Switch
IDF
Intermediate Distribution Frame
IPT
IP Trunk (P2P CCIS) (on CPU)
ISDN
Integrated Service Digital Network
LAN
Local Area Network
LC
Single Line Telephone Interface Blade
LCDB
Expansion Single Line Telephone Interface Blade on LC
MDF
Main Distribution Frame
MEM
Main Memory (on CPU)
MIS
Management Information System
MOH
Music On Hold
OAI
Open Application Interface (on CPU)
ODT
Tie Line Interface Blade (2W/4W E&M)
OPX
Off-Premise Extension
PBR
PB Receiver (on CPU)
PBSND
PB Sender (on CPU)
PCPro
PC Programming
PFT
Power Failure Transfer
PLO
Phase Locked Oscillator (on CPU)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Table 2-1 List of Abbreviations (Continued)
Abbreviation
Description
PMS
Property Management System
PRI
Primary Rate Interface
PRT
Primary Rate Interface Blade
PS
Personal Station
PSA
PSTN Adapter (analog)
PVA
Packet Voice Application
RTB
Router Blade
SERIAL
Serial Port (on CPU)
SLT
Single Line Telephone
SMDR
Station Message Detail Recording
TDSW
Time Division Switch (on CPU)
USB
Universal Serial Bus (on CPU)
CD-VM00
UMS Blade Server Blade
PZ-VM21
VMS Daughter Board with V34 Modem
VMS
Voice Mail System
VoIP
Voice over Internet Protocol
VoIPDB
VoIP daughter board (on CPU)
VRS
Voice Response System
WAN
Wide Area Network
WebPro
Web-Based PC Programming
System Hardware Manual
2-3
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-4
Figure 2-1 SV8100 System Block Diagram
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
2-5
SECTION 3 MAXIMUM SYSTEM CAPACITIES
The CHS2U is a compact 19” chassis that has six universal slots, one expansion
slot and one MPS7101 (power supply unit). When the CD-CP00 is installed in the
first CHS2U, it is referred to as the Controlling Chassis. Additional chassis, referred
to as Expansion Chassis, can be installed to increase the capacity of the system to
meet the customer’s business needs.
As Figure 2-2 19” Controlling and Expansion Chassis and Table 2-2 SV8100
Maximum System Capacities – Trunks/Ports/Channels illustrate, the system can be
expanded from 111 ports to 512 ports by vertically stacking a maximum of three
additional chassis onto the controlling chassis. This provides a maximum of 24 slots
and 368 digital terminals. To obtain the maximum port capacity of 512 ports, two
systems can be linked together via an IP connection.
The maximum slot and channel capacities are listed in Table 2-2 SV8100 Maximum
System Capacities – Trunks/Ports/Channels.
Table 2-2 SV8100 Maximum System Capacities – Trunks/Ports/Channels
19" Chassis
Number of:
x1
(6 slots)
x2
(12 slots)
x3
(18 slots)
x4
(24 slots)
System
Maximum
Number of Timeslots
111
222
333
444
444
Dterm(-48V)
80
176
272
368
SLT(-28V)
80
176
272
368
SLT(-48V)
20
44
68
92
DtermIP
512
SIP/WAN
512
Total 512
Analog Trunks (COT)
40
88
136
184
BRI
40
88
136
184
PRI (30B)
90
180
180
180
IP Trunk (SIP)
200
Total 200
VoIP Channels
128
Conference Circuits
64 (32 parties max per Conference)
Voice Mail Channels on CPU
16 channels
V34 Modem
1 channel
DTMF Receivers
32
32
32
32
96 *1
*1 = An additional 64 DTMF Receivers are available when the PZ-BS10 is installed.
An additional 64 DTMF Receivers are available when the PZ-BS10 is installed. If using
Caller ID to analog trunks and DSP resources are set to common, DSP resources will
only be used for analog trunks and not analog stations.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-6
3.1
System Configuration – SV8100
The SV8100 19” chassis provides 111 total ports (80 digital terminals) and can be
expanded, using three additional 19” chassis, for a maximum of 444 ports (368
digital terminals). Through IP connection and use of additional 19” chassis, the
system can be expanded to a maximum of 512 ports.
The 19” chassis consists of a controlling chassis (chassis with CD-CP00 blade),
and the ability to expand the system using expansion blades depending on system
configuration.
Figure 2-2 19” Controlling and Expansion Chassis
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
2-7
Table 2-3 Maximum System Capacities – Chassis shows the maximum number of
chassis and related equipment that can be installed in a system.
Table 2-3 Maximum System Capacities – Chassis
Hardware
19”
Chassis
with
CPU
19”
Chassis
without
CPU
19”
Chassis
x4
Number
of
Slot(s)
for
Interface Package
5 Slots
6 Slots
23 Slots
Networked
Chassis
Comments
Chassis:
CHS2U
(19” Chassis)
1
1
4
16x(1+3)
Virtual slot in
NetLink is limited
to maximum of
240
Expansion:
PZ-BS10
3-jack Expansion Board for
Controlling Chassis
1
0
1
16x1
-
PZ-BS11
1-jack Expansion Board for
Expansion Chassis
0
1
3
16x3
-
Battery:
CHS LARGE BATT BOX
(External Battery Box)
1
1
4
16x(1+3)
-
Fan Box:
CHS2U FAN BOX SET
1
1
4
-
1 is factory
installed with
each chassis
Power Supply:
MPS7101
1
1
4
-
1 is factory
installed with
each chassis
Table 2-4 SV8100 Maximum System Capacities – Blades shows the maximum
number for each blade that can be installed in a system.
This is determined by the maximum blade configuration allowed. When installing
single line sets, DISA, or tie lines, CPU circuits must be allocated for DTMF
receivers. To install single line sets with CO/PBX line access, or when installing
immediate-start tie lines, CPU circuits must be allocated for dial tone detection.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-8
Table 2-4 SV8100 Maximum System Capacities – Blades
Hardware
19”
Chassis
with
CPU
19”
Chassis
without
CPU
19”
Chassis
x4
Number of Slot(s) for Interface
Package
5 Slots
6 Slots
23 Slots
Networked
Chassis
Comments
Common Control Blades:
CD-CP00
1
0
1
16
Main Processor
Board
PZ-32IPLA
(32-port VoIP Daughter Board)
1
0
1
16
This unit provides
32 VOIP Gateway
channels
PZ-64IPLA
(64-port VoIP Daughter Board)
1
0
1
16
This unit provides
64 VOIP Gateway
channels
PZ-128IPLA
(128-port VoIP Daughter Board)
1
0
1
16
This unit provides
128 VOIP
Gateway
channels
PZ-ME50
(Memory Expansion Board)
1
0
1
16
PZ-VM21
(Voice Mail Daughter)
1
0
1
1
Does include
modem
Station Blades:
CD-4DIOPB
(4 DID/OPX)
5
6
23
50
When
installed
as an OPX blade
CD-4LCA
(4 Single Line Telephone
Interface)
5
6
23
32
-
CD-8LCA
(8 Single Line Telephone
Interface)
5
6
23
32
CD-8DLCA
(8 Digital Station Interface)
5
6
23
32
CD-16DLCA
(16 Digital Station Interface)
5
6
23
32
PZ-8DLCB
(8 Digital Station Interface
Daughter Board)
5
6
23
32
PZ-4LCA
(4 Single Line Telephone
Interface Daughter Board)
5
6
20
32
-
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
2-9
Table 2-4 SV8100 Maximum System Capacities – Blades(continued)
Hardware
19”
Chassis
with
CPU
19”
Chassis
without
CPU
19”
Chassis
x4
Number of Slot(s) for Interface
Package
5 Slots
6 Slots
23 Slots
Networked
Chassis
Comments
Station Blades:
PZ-8LCE(8 Single Line
Telephone Interface Daughter
Board)
5
6
23
32
CD-LTA
(8 Digital/2 Single Line)
1
1
4
5
An optional
PZ-4COTE or
PZ-2BRIA can be
installed
Trunk Blades:
CD-2BRIA
(2 Basic Rate Interface)
5
6
23
25
-
PZ-2BRIA
(2 Basic Rate Interface
Daughter Board)
5
6
23
25
-
CD-4COTA
(4 Loop Start Trunk)
5
6
23
25
-
PZ-4COTE(4 Loop Start Trunk
Daughter Board)
5
6
23
25
-
CD-4DIOPB
(4 DID/OPX)
5
6
23
50
When installed as
a DID blade
CD-4ODTB
(4 E&M)
5
6
23
50
-
CD-PRTA(1 Primary Rate
Interface/T-1/E-1)
3
3
6
6
Blade is used for
Primary Rate
Interface or T-1
Interface or E-1
Optional Blades:
CD-PVAA
(Conference Bridge)
5
6
23
32
CD-ETIA
(Switching Hub with Power over
Ethernet)
3
3
12
64
CD-RTB
(Router)
1
2
7
50
CD-VM00
(Voice Mail and Server)
1
1
1
1
Maximum of One
per system
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-10
Table 2-5 Daughter Board Combinations shows each blade and associated
daughter board combinations. The daughter boards that can be mounted on
specific blades are indicated by a checkmark. For example, the CD-4COTA can
have a PZ-4COTE daughter board mounted.
Table 2-5 Daughter Board Combinations
Daughter Board
Controlling Chassis
PZ-2BRIA
PZ-4COTE
PZ-4LCA
PZ-8LCE
PZ-8DLCB
CD-LTA
(8 Digital/2 Single Line)
○
○
-
-
-
CD-4COTA
(4 Loop Ground Start)
-
○
-
-
-
CD-4LCA
(4 Single Line Interface)
-
-
○
○
-
CD-8LCA(
8 Single Line Interface)
-
-
○
○
-
CD-8DLCA
(8 Digital Station Interface)
-
-
-
-
○
CD-16DLCA
(16 Digital Station Interface)
-
-
-
-
-
CD-2BRIA
(2 Basic Rate Interface)
○
-
-
-
-
- : Does not apply / ○ : Does apply
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
2-11
SECTION 4 POWER-BASED CALUCULATOR CHART
The UNIVERGE SV8100 system uses two types of power factors. For a single
chassis chart refer to Table 2-6 Board Power Factor. For the maximum number of
specific blades per package, see Table 2-7 Maximum Number of Package Installed.
Refer to Table 2-8 Terminal Power Factor on Page 2-12 below, for the Terminal/
Adapter power chart.
Table 2-6 Board Power Factor
Board Power Factor
Total =< 7
Item
Power Factor
CD-CP00
1
CD-RTB
2
CD-VM00
2
CD-ETIA
2
CD-PVAA
1
PZ-32IPLA
1
PZ-64IPLA
2
PZ-128IPLA
2
Table 2-7 Maximum Number of Package Installed
Maximum Number of Package
Installed
Board
(Power Factor)
19 inch
with
CD-CP00
19 inch
without
CD-CP00
4 x 19
inch
CD-ETIA (2)
3
3
12
CD-PVAA (1)
5
6
23
CD-RTB (2)
2
2
8
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-12
Table 2-8 Terminal Power Factor
Terminal Power Factor
Total =< 80
Item
Power Factor
DTL-24D-1( ) TEL
0.8
DTL-8LD-1( ) TEL
0.8
BHA-L UNIT
2
ADA-L UNIT
2
APR-L UNIT
2
APR UNIT
3
BCH-L (BK) UNIT
2
PSA-L UNIT
1.2
8LK-L UNIT
0
DCL-60-1( ) CONSOLE
2
ITL-320C-1( ) TEL
6
ITL-24D-1( ) TEL
4
ITL-2E-1( ) TEL
4
ITL-6DE-1( )TEL
4
SLT(-28V)
0.8
SLT(-48V)
2
IP1WW-2PGDAD
2
IP1E-1SLTAD
5
ITL factors are calculated using the CD-ETIA blade
Table 2-9 IP Terminal Power Chart
Label Indication (Maximum
Current with All Options)
Maximum Current Without
Options
IP
Terminal
IEEE80
2.3af
Class
48VDC
24VDC
48VDC
24VDC
ITL-320C-1( ) TEL
Class 3
160mA
7.7W
290mA
7.0W
111mA
5.3W
192mA
4.6W
ITL-32D-1( ) TEL
Class 2
130mA
6.2W
235mA
5.6W
90mA
4.3W
153mA
3.7W
ITL-8LD-1( ) TEL
Class 2
130mA
6.2W
235mA
5.6W
81mA
3.9W
137mA
3.3W
ITL-24D-1( ) TEL
Class 2
130mA
6.2W
235mA
5.6W
81mA
3.9W
137mA
3.3W
ITL-12D-1( ) TEL
Class 2
130mA
6.2W
235mA
5.6W
81mA
3.9W
137mA
3.3W
ITL-24PA-1( ) TEL
Class 2
130mA
6.2W
235mA
5.6W
-
0.0W
-
0.0W
ITL-24PD-1( ) TEL
Class 2
130mA
6.2W
235mA
5.6W
-
0.0W
-
0.0W
ITL-24BT-1( ) TEL
Class 2
130mA
6.2W
235mA
5.6W
-
0.0W
-
0.0W
ITL-6DE-1( ) TEL
Class 1
68mA
3.3W
122mA
2.9W
68mA
3.3W
122mA
2.9W
ITL-2E-1( ) TEL
Class 1
68mA
3.3W
122mA
2.9W
68mA
3.3W
122mA
2.9W
Label Indication:
IP Value/Sophisticated – Maximum watts when adding options or modular upgrades.
IP Value – Maximum watts when ITL-12D-1( ) TEL is changed to ITL-8LD-1( ) TEL or ITL-24D-1( ) TEL.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
2-13
Table 2-10 IEEE802.af Class Specifications
IEEE802.3af
Minimum
Maximum
Class 4
-
-
Class 3
6.49W
12.95W
Class 2
3.84W
6.49W
Class 1
0.44W
3.84W
Class 0
0.44W
12.95W
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-14
SECTION 5 SYSTEM REQUIREMENT AND SPECIFICATION
5.1
Cabling
This section provides cabling requirements and specifications for various
equipment used in the SV8100 system.
Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable is a diagram of the
chassis connected with each of the multiline terminals and single line telephones by
a separate twisted 1-pair cable or 2-pair cable (only for Multiline Terminals).
Figure 2-3 Connecting the DLC Using Twisted 2-Pair Cable
Refer to the following tables for cabling requirements and specifications.
Table 2-11 DT300 Series Loop Resistance and Cable Length
Table 2-12DT700 Series Loop Resistance and Cable Length
Table 2-13 Dterm Series i or Dterm IP Terminal Loop Resistance and
Cable Length
Table 2-14 Cable Connection Between the Analog Port and the Single Line
Equipment
Table 2-15 Cabling Requirements
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
2-15
Table 2-11 DT300 Series Loop Resistance and Cable Length
Terminal or Adapter
By Twisted 1-Pair
Cable
(without AC
Adapter) 24 AWG
DTL-2E-1( ) (BK) TEL
DTL-6DE-1( ) (BK) TEL
DTL-8LD-1( ) (BK)TEL
DTL-8LD-1( ) (WH) TEL
DTL-12BT-1( ) (BK) TEL
DTL-12PA-1( ) (BK) TEL
DTL-12D-1( ) (BK)TEL
DTL-12D-1( ) (WH) TEL
DTL-24D-1( ) (BK) TEL
DTL-24D-1( ) (WH) TEL
DTL-32D-1( ) (BK)TEL
DTL-32D-1( ) (WH) TEL
DCL-60-1( ) Console*
1,969 ft (600m)
*An AC Adapter is required.
Table 2-12 DT700 Series Loop Resistance and Cable Length
Terminal or Adapter
Ethernet Cable
ITL-2E-1( ) (BK) TEL
ITL-6DE-1( ) (BK) TEL
ITL-8LD-1( ) (BK) TEL
ITL-8LD-1( ) (WH) TEL
ITL-12BT-1( ) (BK) TEL
ITL-12D-1( ) TEL
ITL-12D-1( ) (WH) TEL
ITL-12PA-1( ) (BK) TEL
ITL-24D-1( ) (BK) TEL
ITL-24D-1( ) (WH) TEL
ITL-32D-1( ) (BK) TEL
ITL-32D-1( ) (WH) TEL
ITL-32OC-1( ) (BK) TEL
Cat 5/Cat 6 Ethernet
328.1 ft (100m)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-16
Table 2-13 Dterm Series i or Dterm IP Terminal Loop Resistance and Cable Length
Terminal or
Adapter
Maximum
Loop
Resistance
(without AC
Adapter)
(Ohms)
By Twisted
1-Pair Cable
(without AC
Adapter)
24 AWG
By Twisted
2-Pair Cable
(without AC
Adapter)
24 AWG
Maximum
Loop
Resistance
(with AC
Adapter)
(Ohms)
By Twisted
1-Pair Cable
(with AC
Adapter)
24 AWG
By Twisted
2-Pair Cable
(with AC
Adapter)
24 AWG
DTH-8-1TEL
DTR-8-1 TEL
37
700
1400
107
2000
2000
DTH-8D-1TEL
DTR-8D-1TEL
37
700
1400
107
2000
2000
DTH-16-1TEL
DTR-16-1 TEL
35
660
1320
107
2000
2000
DTH-16D-1TEL
DTR-16D-1TEL
35
660
1320
107
2000
2000
DTH-32D-1TEL
DTR-32D-1TEL
26
500
1000
107
2000
2000
DTH-16LD-1 TEL
37
700
1400
107
2000
2000
DCR-60-1 Console*
-
-
-
107
2000
2000
*An AC Adapter is required.
Table 2-14 Cable Connection between the Analog Port and the Single Line Equipment
Connected Equipment
Cable
Maximum Feet from Connected
Equipment to Telephone
ADA-L UNIT
Twisted Pair
9.5 ft (2.89m)
APR-L UNIT
Twisted Pair
50 ft (15.24m)
BCH-L (BK) UNIT
NEC Provided
4 in (101.6mm)
PSA-L UNIT
Twisted Pair
1,700 ohms
Analog Telephone (SLT, G3FAX, etc.)
Twisted Pair
1500m with 24 AWG
LCA
Twisted Pair
1500m with 24 AWG
Mixing digital and analog ports through the same 25-pair cable runs is not recommended.
Table 2-15 Cabling Requirements
Connected Equipment
Cable
Music on Hold and Background Music Sources
Hi-Fi Shielded Audio Cable
External Amplifier
Hi-Fi Shielded Audio Cable
ITL Cabling
Cat 5 Straight Data Network Cable – 328.1 ft (100m)
maximum distance.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
A dedicated 100VAC/120VAC/220VAC/230-240VAC 50/60 Hz circuit located within
seven feet of the chassis is required. A separate dedicated outlet for each chassis
should be installed
Double Pole/Neutral Fusing
(Power supply fuses are located at both the L and N side).
5.2.1
Power Supply Specification
Table 2-16 AC Power Supply:
System Hardware Manual
2-17
110VAC
220VAC
230-240VAC
Power
Requirements
110 VAC @ 15A
Controlling/Base
Chassis
220VAC @ 15A
Controlling/Base
Chassis
230-240 VAC @
15A
Controlling/Base
Chassis
Power
Consumption
Base Chassis
= 259VA
4 Chassis total
= 1036VA
Base chassis
= 262VA,
4 Chassis total
= 1048VA
Base chassis
= 276VA
(1.15Ax240V),
4 Chassis total
= 1104VA
Input Voltage
(Rated Voltage)
90VAC to 264VAC
(100VAC/120VAC/220VAC/230-240VAC)
Frequency
47Hz - 63Hz (Rated frequency: 50/60Hz)
Phase and Wire
Single Phase,
2 Line + PE Type
Grounding
Requirements
No. 14 AWG
copper wire
Feeding Voltage
Dterm/OPX/DID: -48V
SLT: 25mA / -28V
Output Power
Base chassis
= 130W,
4 chassis total
= 520W
Base chassis
= 130W,
4 chassis total
= 520W
Base chassis
= 130W,
4 chassis total
= 520W
AC Input I
Base chassis
= 2.35A,
4 chassis total
=9.4A
Base chassis
= 1.19A,
4 chassis total
= 4.76A
Base chassis
= 1.15A,
4 chassis total
= 4.6A
VA @ 110V/:
VA @ 220V/
VA @ 230V-240V
Base Chassis
= 259VA
4 Chassis total
= 1036VA
Base Chassis
= 262VA
4 Chassis total
= 1048VA
Base Chassis
= 276VA
(1.15Ax240V)
4 Chassis total
=1104VA
KWh @ AC Input I x
110V/1000/
KWh @ AC Input I x
220V/1000/
KWh @ AC Input I x
230-240V/1000
Base chassis
= 0.259 KWh,
4 chassis total
= 1.036 KWh
Base chassis
= 0.262 KWh,
4 chassis total
= 1.048 KWh
Base chassis
= 0.276 KWh
(1.15Ax240V) ,
4 chassis total
= 1.104 KWh
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-18
A dedicated outlet, separately fused and grounded for each chassis
should be installed.
Double Pole/Neutral Fusing
(Power supply fuses are located at both the L and N side).
5.2.2
Power Supply Consumption
Table 2-17 Power Consumption
Chassis
Voltage
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
110VAC
2.35A
220VAC
1.19A
Basic Chassis – CD-CP00 Chassis
230-240VAC
1.15A
96
130
110VAC
4.7A
220VAC
2.38A
Basic Chassis + Expansion Chassis
230-240VAC
2.3A
192
260
110VAC
7.05A
220VAC
3.57A
Basic Chassis + 2 Expansion
Chassis
230-240VAC
3.45A
288
390
110VAC
9.4A
220VAC
4.76A
Basic Chassis + 3 Expansion
Chassis
230-240VAC
4.6A
384
520
5.3
Environmental Conditions
5.3.1
Temperature and Humidity
Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR
Operating Temperature: 0°C ~ 40°C
Recommended Long Term Temperature: -20°C ~ 60°C
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Blades - PZ-BS10, PZ-BS11, PZ-VM21, PZ-ME50, CD-8DLCA,
CD-16DLCA, PZ-8DLCB
Operating Temperature: 0°C ~ 40°C
Recommended Long Term Temperature:-20°C ~ 60°C
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
2-19
Blades - CD-4LCA, PZ-4LCA, CD-8LCA, PZ-8LCE, CD-4COTA,
PZ-4COTE, CD-PRTA
Operating Temperature: 0°C ~ 40°C
Recommended Long Term Temperature:-20°C ~ 60°C
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Door Box
Operating Temperature: -20°C ~ 60°C)
Operating Humidity: 20 ~ 80% RH (non-condensing)
SV8100 Power Supply – MPS7101
Operating Temperature: 0°C ~ 40°C
Recommended Long Term Temperature:-40°C ~ 75°C)
Operating Humidity: 20 ~ 95% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 95% RH
5.4
Outside Line Type
The following outside lines can be used with the UNIVERGE SV8100 system.
4-wire, E&M Tie Lines (Type I or V, Dial Pulse, or DTMF)
Digital Trunk T1/FT1/E1 (Loop Start, Ground Start, Tie Line (E&M), or DID
Signaling)
ISDN-BRI Trunks
ISDN-PRI Trunks
VoIP Trunks (Internet Protocols)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-20
5.5
Transmission, Network and Control Specifications
5.5.1
Transmission
Data Length:
From Multiline Terminal to CD-8DLCA: 23 bits
From CD-8DLCA to Multiline Terminal: 23 bits
Data Transmission Rates:
Between CD-8DLCA and Multiline Terminal: 184K bps (voice and
signaling)
Scanning Time for each Multiline Terminal: 32 ms.
5.5.2
Network
Time Division Multiplexing (TDM) allows transmission of data and voice
simultaneously over one communications medium. The specifications that
the UNIVERGE SV8100 system uses for switching, clock, data bus, and
timeframe are shown below.
TDM Switching: PCM (A-Law)
TDM Clock: 2.048 MHz
TDM Data Bus: 8 bit
TDM Timeframe: 125 µs.
5.5.3
Control
This section indicates the speed or capacity:
Control: Stored program with distributed processing
Central Processor: 32-bit microprocessor
Clock: 266 MHz
Interface Blade: 8- or 16-bit microprocessor
Optional Blades: 16- or 32-bit microprocessor
Multiline Terminal (TDM): 8-bit microprocessor
Multiline Terminal (IP): 32-bit microprocessor
IP Adapter: 32-bit microprocessor
Attendant Console: 4-bit microprocessor
IP1E-1SLTAD: 4-bit microprocessor
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Dial Pulse Address Signaling
Dial Pulse Address Signaling uses dial pulses (regular momentary
interruptions) to signal the equipment. The following Dial Pulse
specifications are used In the UNIVERGE SV8100 system.
Pulse Rate: 10 ± 0.5 pps/20 ± 1.0 pps
Percent Break: 60 ± 1.5%
Interdigit Interval: 0 pps/20 pps 770 ms. ~ 830 ms.
5.7.2
Dual-Tone Multifrequency (DTMF) Address Signaling
DTMF signaling includes push button or Touchtone dialing. When a key
on a telephone is pushed, two tones (one high frequency and one low
frequency) are provided. In the UNIVERGE SV8100 system, the following
DTMF specifications are used.
Frequencies:
Two sinusoidal frequencies are provided, one from the high frequency
group and one from the low frequency group.
Frequencies Deviation: Less than ±1.5%
Signal Level:
Nominal level per frequency: -6 ~ -4 dBm
Minimum level per frequency
Low Group: -10 dBm
High Group: -8 dBm
Maximum level per frequency: 0 dBm
Rise Time: Within 5 ms.
Duration of Dual Frequency Signal:
110 ms. default/60 ms. Minimum
Interdigital Time: 140 ms. default/45 ms. minimum
System Hardware Manual
2-21
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-22
5.6.3
External Equipment Connection
Door Phone or TV Door Phone
External Speaker via amplifier
External music source for MOH and BGM
Tape recorder for voice recording via IP1WW-2PGDAD
Door Lock/Release or General Purpose Relay via IP1WW-2PGDAD
Printer for SMDR by LAN
PC by LAN
5.6.4
Music Source for Music on Hold via Chassis
Auxiliary Input: 0.6V PPS Signal Level
Input Impedance: 600 Ω
5.6.5
Music Source for Station Background Music via ACI
Auxiliary Input: 0.6V PPS Signal Level
Input Impedance: 600 Ω
5.6.6
External Paging (Audio)
Output Power: –10 dBm Signal Level
Output Impedance: 600 Ω
Relay Contact Rating: 500 mA, 24 Vdc
5.6.7
External Tone Ringer/Night Chime Output
Output Power: –10 dBm
Output Impedance: 600 Ω
Relay Contact Rating: 500 mA, 24 Vdc
5.6.8
SMDR
Female Connector (LAN) Standard DB-9 (straight)
5.6.9
PC Connection
Female Connector (LAN) Standard DB-9 (straight)
5.6.10
Relay Connection
All Relay Contact Ratings: 500 mA, 24Vdc
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
2-23
5.7
Battery Backup
The UNIVERGE SV8100 system has battery backup functions for system backup
and for memory backup.
5.7.1
System Backup (Optional)
During a power failure, the system can be backed up using the CHS2U
BATT MTG KIT for a backup time of 10 minutes or one of the CHS LARGE
BATT SETs for a backup time ranging from 45~180 minutes.
5.7.2
Memory Backup
The CD-CP00 Blade battery retains the Clock/Calender and Last Number
Redial (LNR) buffers for each station when the CD-CP00 Blade
encounters a power loss. With a fully charged battery, the settings are
retained for about three years. The System Programmed memory
(Customer Database) is stored in non-volatile Memory and can be erased
only by a First Initialization. After power is restored, the system Blade
returns to normal operation.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-24
5.8
Weights and Dimensions
Table 2-18 SV8100 Weights and Dimensions shows the shipping weight, height,
width and depth of each SV8100 digital multiline terminal, IP multiline terminal,
Dterm, Series i multiline terminal, chassis, assorted blades and adapters.
Table 2-18 SV8100 Weights and Dimensions
Unit
Shipping
Weight
Height
Width
Depth
SV8100
CHS2U
278.7 oz
(7.9 kg)
3.47 in
(88 mm)
16.9 in
(430 mm)
14.17 in
(360 mm)
CD-CP00
7.06 oz
(0.2 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.09 in
(180 mm)
PZ-ME50
.353 oz
(0.01 kg)
0.12 in
(3 mm)
2.56 in
(65 mm)
1.22 in
(31 mm)
CD-LTA
6.70 oz
(0.19 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.09 in
(180 mm)
CHS LARGE BATT BOX
352.7 oz
(10 kg)
23.23 in
(590 mm)
17.72 in
(450 mm)
10.43 in
(265 mm)
CHS LARGE BATT SET
194 oz
(5.5 kg)
6.69 in
(170 mm)
5.91 in
(150 mm)
4.33 in
(110mm)
Common
MPS7101
31.75 oz
(0.9 kg)
2.36 in
(60 mm)
7.08 in
(180 mm)
6.10 in
(155mm)
PZ-BS10
2.29 oz
(0.065 kg)
0.91 in
(23 mm)
2.17 in
(55 mm)
7.28 in
(185 mm)
PZ-BS11
1.975 oz
(0.056 kg)
0.91 in
(23 mm)
2.17 in
(55 mm)
7.28 in
(185 mm)
PZ-VM21
1.76 oz
(0.05 kg)
0.60 in
(15 mm)
2.09 in
(53 mm)
3.35 in
(85 mm)
PZ-32IPLA
1.76 oz
(0.05 kg)
0.60 in
(15 mm)
3.15 in
(80 mm)
6.3 in
(160 mm)
PZ-64IPLA
1.76 oz
(0.05 kg)
0.60 in
(15 mm)
3.15 in
(80 mm)
6.3 in
(160 mm)
PZ-128IPLA
1.76 oz
(0.05 kg)
0.60 in
(15 mm)
3.15 in
(80 mm)
6.3 in
(160 mm)
CD-8DLCA
5.86 oz
(0.167 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.09 in
(180 mm)
PZ-8DLCB
4.41 oz
(0.125 kg)
0.60 in
(15 mm)
4.72 in
(120 mm)
5.12 in
(130 mm)
CD-16DLCA
7.831 oz
(0.222 kg)
1.89 in
(48 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CD-4COTA
6.35 oz
(0.18 kg)
1.89 in
(48 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
PZ-4COTE
3.53 oz
(0.10 kg)
1.89 in
(48 mm)
9.45 in
(240 mm)
5.12 in
(130 mm)
CD-4LCA
5.99 oz
(0.17 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
PZ-4LCA
3.10 oz
(0.09 kg)
0.60 oz
(15 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
2-25
Table 2-18 SV8100 Weights and Dimensions (Continued)
Unit
Shipping
Weight
Height
Width
Depth
CD-8LCA
6.46 oz
(0.183 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
PZ-8LCE
3.70 oz
(0.105 kg)
0.60 oz
(15 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CD-2BRIA
5.99 oz
(0.17 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
PZ-2BRIA
4.02 oz
(0.114 kg)
0.60 oz
(15 mm)
4.72 in
(120 mm)
7.68 in
(195 mm)
CD-PRTA
5.5 oz
(0.156 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CD-4ODTB
8.25 oz
(0.234 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CD-RTB
12.17 oz
(0.345 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.68 in
(195 mm)
CD-VM00
7.76 oz
(0.22 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CD-PVAA
10.05 oz
(0.285 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.68 in
(195 mm)
CD-ETIA
12.17 oz
(0.345 kg)
0.98 in
(25 mm)
5.71 in
(145 mm)
7.68 in
(195 mm)
CD-4DIOPB
7.73 oz
(0.219 kg)
0.98 in
(25 mm)
9.45 in
(240 mm)
7.68 in
(195 mm)
CHS BASE UNIT
21.87 oz
(0.62 kg)
23.23 in
(590 mm)
17.72 in
(450 mm)
10.43 in
(265 mm)
CHS2U BLANK SLOT COVER KIT
1.76 oz
(0.05 kg)
2.32 in
(60 mm)
1.57 in
(40 mm)
1.57 in
(40 mm)
CHS L BATT BOX RACK MOUNT BRACKET
352.7 oz
(10 kg)
18.5 in
(470 mm)
14.6 in
(370 mm)
2.76 in
(70 mm)
CHS2U INT BATT SET
95.24 oz
(2.7 kg)
4.33 in
(110 mm)
2.76 in
(70 mm)
3.15 in
(80 mm)
CHS2U RACK MOUNT KIT
17.6 oz
(0.5 kg)
0.91 in
(23 mm)
9.65 in
(245 mm)
3.35 in
(85 mm)
CHS1U/2U WALL MOUNT KIT
35.27 oz
(1 kg)
1.18 in
(30 mm)
13.8 in
(350 mm)
1.77 in
(45 mm)
CHS LARGE BATT BOX
458.6 oz
(13 kg)
5.24 in
(133 mm)
16.93 in
(430 mm)
14.3 in
(363 mm)
CHS2U JOINT BRACKET KIT
7.06 oz
(0.2 kg)
0.19 in
(3 mm)
5.91 in
(150 mm)
1.7 in
(43 mm)
CHS2U BATT MTG KIT 6 Slot
106 oz
(3.0 kg)
2.95 in
(75 mm)
4.45 in
(113 mm)
4.13 in
(105 mm)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-26
Table 2-18 SV8100 Weights and Dimensions (Continued)
Unit
Shipping
Weight
Height
Width
Depth
Digital Multiline Terminal
DTL-2E-1( ) (BK) TEL
35.27 oz
(1.0 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
8.86 in
(225 mm)
DTL-6DE-1( ) (BK) TEL
38.8 oz
(1.1 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
8.86 in
(225 mm)
DTL-8LD-1( ) (BK) TEL
DTL-8LD-1( ) (WH) TEL
45.6 oz
(1.3 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
10.39 in
(225 mm)
DTL-12BT-1( ) (BK) TEL
45.6 oz
(1.3 kg)
4.29n
(109 mm)
7.6 in
(183.mm)
10.16 in
(258 mm)
DTL-12PA-1( ) (BK) TEL
45.6 oz
(1.3 kg)
4.41 in
(112 mm)
7.6 in
(183.mm)
10.16 in
(258 mm)
DTL-12D-1( ) (BK) TEL
DTL-12D-1( ) (WH) TEL
42.33 oz
(1.2kg)
4.39 in
(111.7 mm)
7.05 in
(179.mm)
10.16 in
(258 mm)
DTL-24D-1( ) (BK) TEL
DTL-24D-1( ) (WH) TEL
42.33 oz
(1.2kg)
4.39 in
(111.7 mm)
7.05 in
(179.mm)
10.16 in
(258 mm)
DTL-32D-1( ) (BK) TEL
DTL-32D-1( ) (WH) TEL
45.6 oz
(1.3 kg)
4.39 in
(111.7 mm)
8.1 in
(205.8 mm)
10.16 in
(258 mm)
IP Multiline Terminal
ITL-2E-1( ) (BK) TEL
35.27 oz
(1.0 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
8.86 in
(225 mm)
ITL-6DE-1( ) (BK) TEL
38.8 oz
(1.1 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
8.86 in
(225 mm)
ITL-8LD-1( ) (BK) TEL
ITL-8LD-1( ) (WH) TEL
45.6 oz
(1.3 kg)
4.41 in
(112 mm)
7.05 in
(179 mm)
10.39 in
(225 mm)
ITL-12BT-1( ) (BK) TEL
45.6 oz
(1.3 kg)
4.29n
(109 mm)
7.59 in
(193.mm)
10.16 in
(258 mm)
ITL-12D-1( ) (BK) TEL
ITL-12D-1( ) (WH) TEL
42.33 oz
(1.2kg)
4.41 in
(112 mm)
7.05 in
(179.mm)
10.16 in
(258 mm)
ITL-12PA-1( ) (BK) TEL
45.6 oz
(1.3 kg)
4.41 in
(112 mm)
7.59 in
(193.mm)
10.16 in
(258 mm)
ITL-24D-1( ) (BK) TEL
ITL-24D-1( ) (WH) TEL
42.33 oz
(1.2kg)
4.41 in
(112 mm)
7.05 in
(179.mm)
10.16 in
(258 mm)
ITL-32D-1( ) (BK) TEL
ITL-32D-1( ) (WH) TEL
45.6 oz
(1.3 kg)
4.41 in
(112 mm)
8.1 in
(205.8 mm)
10.16 in
(258 mm)
ITL-320C-1( ) (BK) TEL
56.44 oz
(1.6 kg)
4.41 in
(112 mm)
8.94 in
(227 mm)
9.84 in
(250 mm)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
2-27
Table 2-18 SV8100 Weights and Dimensions (Continued)
Unit
Shipping
Weight
Height
Width
Depth
Optional
8LK-L (BK) UNIT
8LK-L (WH) UNIT
7.05 oz
(0.2 kg)
1.77 in
(45 mm)
1.15 in
(29.3 mm)
8.82 in
(224 mm)
ADA-L UNIT
2.82 oz
(0.08 kg)
0.98 in
(25 mm)
2.56 in
(65 mm)
3.23 in
(82 mm)
APR-L UNIT
5.29 oz
(0.15 kg)
0.98 in
(25 mm)
2.56 in
(65 mm)
3.23 in
(82 mm)
BCH-L (BK) UNIT
5.29 oz
(0.15 kg)
4.41 in
(112 mm)
2.52 in
(64 mm)
8.8 in
(223 mm)
BHA-L UNIT
3.53 oz
(0.1 kg)
0.98 in
(25 mm)
2.56 in
(65 mm)
2.84 in
(72 mm)
IPLA-RP( ) UNIT
2.82 oz
(0.08 kg)
0.98 in
(25 mm)
2.24 in
(57 mm)
3.94 in
(100 mm)
IP1WW-2PGDAD
12.4 oz
(0.35 kg)
1.58 in
(40 mm)
6.81 in
(173 mm)
4.13 in
(105 mm)
DCL-60-1( ) (BK) CONSOLE
DCL-60-1( ) (WH) CONSOLE
21.16 oz
(0.6 kg)
3.23 in
(82 mm)
5.39 in
(137 mm)
8.82 in
(224 mm)
PSA-L (BK) UNIT
PSA-L (WH) UNIT
10.58 oz
(0.3 kg)
3.15 in
(80 mm)
2.91 in
(74 mm)
8.8 in
(223 mm)
DSS WM-L UNIT
1.41 oz
(0.04 kg)
0.99 in
(25.3 mm)
3.4 in
(86.5 mm)
4.92 in
(125 mm)
WM-L UNIT
1.58 oz
(0.045 kg)
0.996 in
(25.3 mm)
3.996 in
(101.5 mm)
4.92 in
(125 mm)
1 Shipping weight includes the shipping carton.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
SV8100 System Specifications
2-28
- - NOTES - -
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-1
Chapter3; Installing the SV8100 Chassis
SECTION 1 GENERAL INFORMATION
This chapter contains information to help the technician install the chassis for the
SV8100 system. The technician should be familiar with this section before
installing any equipment.
SECTION 2 INSTALLING THE CHASSIS
The CHS2U chassis has six universal blade slots for legacy line/trunk blade (Single
Line Telephone Interface, Digital Multiline Terminal Interface, Central Office Trunk,
ISDN PRI Interface, etc.), In-skin Application Blades (In-skin UMS, In-Skin Router,
etc.). It also houses the BUS Interface Blade, Power Supply Unit (PSU) and
Cooling FAN.
When the CD-CP00 blade is installed in the first 19” chassis, it is referred to as the
controlling chassis. Additional chassis, referred to as expansion chassis, can be
installed to increase the capacity of the system to meet the customer’s business
needs. Each chassis (Expansion or Controlling), is powered by a MPS7101 power
supply.
The chassis can be wall mounted, floor mounted, stand mounted or rack mounted.
The first part of this chapter describes the differing types of mounting options and
the rest of this section describes how to install the chassis.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-2
Universal Slot for Legacy Line/Trunk blades and
Application blades (six slots). When used as
controlling chassis, the CD-CP00 is mounted in
Slot1 (shown)
Slot for PZ-BS10/PZ-BS11 blade
–Connection with CHS2U chassis
Power Switch
Figure 3-1 CHS2S Chassis (Front View)
2.1 Wall Mounting the 19” Chassis
When wall mounting the chassis, ensure the wall can support the weight of the
chassis (55 lbs per system chassis ---- including blades, cords, power supply, etc.).
The chassis is secured to the wall with a wall mount bracket. Ensure that enough
space is available to allow the installation of additional expansion chassis.
Figure 3-2 CHS2S Chassis (Rear View)
AC Connector
Fan Unit
Internal Battery Mount
(inside of cover)
Battery Connector
(inside of cover)
Frame Ground
(FG) Terminal
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-3
2.1.1
CHS2U Chassis Wall Mount Installation
1. Use the template shown in Figure 3-3 Wall Mount Spacing Guide (19”
Chassis) for required spacing before drilling.
Plywood should first be installed on the wall where the
chassis will be positioned. This allows secure
anchoring of the screws which support the weight of
the chassis.
Due to chassis weight, NEC recommends only a single
CHS2U chassis per wall mount.
Figure 3-3 Wall Mount Spacing Guide (19” Chassis)
2. Mark and drill the six holes required for a wall installation.
3. Align screw holes in wall mount brackets with drilled holes.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-4
4. Using six screws, secure the two wall mount brackets to the wall.
Refer to Figure 3-4 Install Wall Mount Brackets with Screws for screw
location.
Figure 3-4 Install Wall Mount Brackets with Screws
5. Using four screws, secure the metal fittings on the Left and Right
sides of the 19” chassis. Refer to Figure 3-5 Install Wall Mount
Brackets with Screws on page 3-5 for screw location.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-5
Figure 3-5 Install Wall Mount Brackets with Screws
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-6
6. Align the metal fitting with the upper wall mount bracket. The lower
metal fitting rests against the lower wall mount bracket. Secure the
metal fitting and upper wall mount bracket with a single screw (see
Figure 3-6 Secure Metal Fitting to Upper Wall Mount Bracket with a
Screw).
Figure 3-6 Secure Metal Fitting to Upper Wall Mount Bracket with Screws
7. Using two screws, secure the metal fitting to the lower wall mount
bracket. Refer to Figure 3-7 Secure Metal Fitting to Lower Wall Mount
Bracket with Screws on page 3-7 for screw location.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Figure 3-7 Secure Metal Fitting to Lower Wall Mount Bracket with Screws
8. Attach the supplied cable support bracket to either end of the lower
wall mount bracket with a single screw (refer to Figure 3-8 Attach
Cable Support Bracket with Screw on page 3-8).
System Hardware Manual
3-7
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-8
Figure 3-8 Attach Cable Support Bracket with Screw
9. The cable support bracket can be installed any of the four corners of
the 19” chassis (refer to Figure 3-9 Attach Cable Support Bracket with
Screw).
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Figure 3-9 Attach Cable Support Bracket with Screw
10. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19”
Chassis Grounding on page 3-33 for complete details on grounding
the system.
11. Refer to 2.5 Installing the 19” Chassis on page 3-21 to continue
installation of the chassis or, Chapter 4 paragraph 2.2 Installing an
Extension or Trunk Blade on page 4-4 for installation of blades.
System Hardware Manual
3-9
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-10
2.2
Floor Mounting the 19” Chassis
The CHS2U controlling and expansion chassis can be mounted on the floor using
the CHS BASE UNIT and the CHS2U JOINT BRACKET KIT.
2.2.1
CHS2U Chassis Installation
1. Use the template shown in Figure 3-10 Floor Mount Spacing Guide for
required spacing before drilling holes for 0.39” (10mm) anchor bolts
(locally procured).
Figure 3-10 Floor Mount Spacing Guide
2. Mark and drill the four holes required for installing the CHS BASE
UNIT.
3. Using anchor bolts, secure the CHS BASE UNIT to the floor. Refer to
Figure 3-11 Secure CHS BASE UNIT with Anchor Bolts on page 3-11
for screw location.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-11
Figure 3-11 Secure CHS BASE UNIT with Anchor Bolts
4. Install the five rubber feet to the bottom of the chassis.
Figure 3-12 Install Rubber Feet
5. Position the chassis on top of the CHS BASE UNIT.
6. Secure the chassis to the CHS BASE UNIT using eight screws
supplied with the CHS2U JOINT BRACKET KIT.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-12
Figure 3-13 Install CHS2U JOINT BRACKET KIT
7. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19”
Chassis Grounding on page 3-33 for complete details on grounding
the system.
8. Refer to 2.5 Installing the 19” Chassis on page 3-22 to continue
installation of the chassis or, Chapter 5 paragraph 2.2 Installing an
Extension or Trunk Blade on page 4-4 for installation of blades.
2.2.2
Multiple CHS2U Chassis Installation
Expansion chassis can be secured to the CHS BASE UNIT and will
require an additional CHS2U JOINT BRACKET KIT per chassis.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-13
1. Install the five rubber feet to the bottom of each chassis.
Figure 3-14 Install Rubber Feet
2. Using supplied screws in the CHS2U JOINT BRACKET KIT, attach
metal brackets to both ends of the 19” chassis and the CHS BASE
UNIT. Refer to Figure 3-15 Install Metal Brackets with Screws.
Figure 3-15 Install Metal Brackets with Screws
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-14
3. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19”
Chassis Grounding on page 3-33 for complete details on grounding
the system.
4. Refer to 2.5 Installing the 19” Chassis on page 3-21 to continue
installation of the chassis or, Chapter 4 paragraph 2.2 Installing an
Extension or Trunk Blade on page 4-4 for installation of blades.
2.3
Stand Mounting the 19” Chassis
A single or multiple chassis can be stand mounted. Controlling and Expansion
chassis can be stand mounted using the CHS2U STAND KIT (K) and CHS2U
STAND KIT (EXT).
2.3.1
CHS2U Chassis Installation
1. Using the supplied screws, assemble the CHS2U STAND KIT (K) and
CHS2U STAND KIT (EXT) (refer to Figure 3-16 Assemble Stand
Mount with Screws).
Figure 3-16 Assemble Stand Mount with Screws
2. Secure the CHS2U chassis to the assembled CHS2U STAND KIT
refer to Figure 3-17 Secure CHS2U Chassis to CHS2U STAND KIT
with Screws on page 3-15.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-15
Figure 3-17 Secure CHS2U Chassis to CHS2U STAND KIT with Screws
3. Using supplied screws, secure the CHS2U STAND KIT to the floor
(refer to Figure 3-18 Secure Stand Mount to Floor with Screws on
page 3-16).
To prevent possible damage to the 19” chassis due
to falling, NEC recommends screws be installed in
the stand mount brackets as soon as possible.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-16
Figure 3-18 Secure Stand Mount to Floor with Screws
4. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19”
Chassis Grounding on page 3-33 for complete details on grounding
the system.
5. Refer to 2.5 Installing the 19” Chassis on page 3-21 to continue
installation of the chassis or, Chapter 4 paragraph 2.2 Installing an
Extension or Trunk Blade on page 4-4 for installation of blades.
2.3.2
Multiple CHS2U Chassis Installation
Expansion chassis (maximum of three) can be added to the CHS2U
STAND KIT and will require an additional CHS2U STAND KIT (EXT) per
chassis.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-17
1. Install the five rubber feet to the bottom of each chassis.
2. Each additional chassis will require CHS2U STAND KIT (EXT) to be
installed (refer to Figure 3-20 Install Additional CHS2U STAND KIT
(EXT)).
Figure 3-19 Attach Rubber Feet to CHS2U Chassis
Figure 3-20 Install Additional CHS2U STAND KIT (EXT)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-18
3. Metal brackets from the CHS2U JOINT BRACKET KITs will be
required to secure the top end of the chassis with screws. See Figure
3-21 Install Additional CHS2U STAND KIT (EXT) on page 3-18.
Figure 3-21 Install Additional CHS2U STAND KIT (EXT)
4. Using supplied screws, secure the CHS2U STAND KIT to the floor
(refer to Figure 3-21 Install Additional CHS2U STAND KIT (EXT) on
page 3-18).
To prevent possible damage to the 19” chassis due
to falling, NEC recommends screws be installed in
the stand mount brackets as soon as possible.
5. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19”
Chassis Grounding on page 3-33 for complete details on grounding
the system.
6. Refer to 2.5 Installing the 19” Chassis on page 3-21 to continue
installation of the chassis or, Chapter 4 paragraph 2.2 Installing an
Extension or Trunk Blade on page 4-4 for installation of blades.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-19
2.4
Rack Mounting the 19” Chassis
A single or multiple chassis can be rack mounted. Controlling and Expansion
chassis can be racked mounted by stacking them horizontally..
1. The 19” chassis requires two rack mount brackets per chassis for mounting.
Each 19" chassis requires its own set of rack mount bracket(s). Refer to
Figure 3-22 CHS2U Rack Mount Brackets.
Stacking additional chassis (without rack mount brackets)
on top of one rack mounted chassis is not recommended.
Figure 3-22 CHS2U Rack Mount Bracket
2. Line up the Rack Mount Bracket(s) with the pre-drilled holes on each side of
the 19” chassis.
3. Secure the brackets to the chassis using the supplied screws. Refer to Figure
3-23 Rack Mount Bracket Installed 19” CHS2U on page 3-20 for the 19”
chassis.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-20
Repeat for additional chassis mounting.
Figure 3-23 Rack Mount Bracket Installed 19”CHS2U
4. Carefully slide the chassis into desired location in the rack. Make sure the
hooks on the mounting bracket are inserted into the back of the chassis,
securing it in place. Note that the cabling is run through the front of the rack for
ease of access.
Each CHS2U chassis will require approximately 3.5” of
height within the rack.
5. Secure the brackets to the rack using the screws supplied.
Repeat for additional chassis mounting.
Figure 3-24 Rack Mount 19”CHS2U
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-21
6. Connect the ground wire to all chassis. Refer to 2.5.5 Install 19” Chassis
Grounding on page 3-33 for complete details on grounding the system.
7. Refer to 2.5 Installing the 19” Chassis on page 3-21 to continue installation of
the chassis or, Chapter 4 paragraph 2.2 Installing an Extension or Trunk Blade
on page 4-4 for installation of blades.
2.5
Installing the 19” Chassis
There are two types of chassis; the controlling (with the CD-CP00 installed) and the
expansion (that does not have the CD-CP00 blade installed). As discussed in
other chapters, multiple chassis can be linked together to expand the port size of
the system.
2.5.1
Unpacking the Equipment
Inspect the equipment for any physical damage. If you are not sure about
the function of a component, review the associated information within this
manual. Contact your authorized NEC Sales Representative if you have
additional questions. Note that the chassis does not initially contain any
blades.
Make sure you have appropriate tools for the job, including: a test set, a
punch down tool, and a digital voltmeter.
Ensure that you have a building plan showing common equipment,
extensions, the Telco demarcation and earth ground location before you
start installation. Be sure to properly plan your installation site and that you
are familiar with the installation safety precautions. If you have not done
that, please do so now.
2.5.2
Before Installation
Before installing the chassis check the following:
Ensure that the MPS7101 (Power Supply Unit) is OFF and that that
the power cord is disconnected from the AC outlet.
When installing the blades, do not touch the soldered surfaces as this
may cause damage.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-22
2.5.3
Installing the 19” Controlling Chassis
1. Ensure the chassis is powered down.
Do not remove or install this blade with the power on.
2. Align the CD-CP00 blade with the Slot 1 Guides of the Controlling
Chassis.
Figure 3-25 19"Controlling Chassis – Slot 1 Guides
3. Slide the CD-CP00 blade into the chassis until resistance (back plane)
is felt.
Figure 3-26 Installing the CD-CP00 Blade
4. Gently push until the blade seats. Tighten the two retaining screws on
front of the blade.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-23
Figure 3-27 CD-CP00 Blade Installed
2.5.4
Installing Expansion Blade in the 19” Chassis (Optional)
When adding additional chassis to the system to expand the capacity, a
PZ-BS10 must be installed in the Controlling Chassis and a PZ-BS11 must
be installed in all Expansion Chassis. This connection is required with
any multiple-chassis setup.
The PZ-BS10 connects the Controlling Chassis to the Expansion Chassis
by connecting to a PZ-BS11, which is installed on each Expansion
Chassis. These Expansion Interface Units allow the CPU to
transmit/receive data as required to the additional chassis.
The PZ-BS10 is installed in the Expansion Bay of the Controlling Chassis
which is equipped with a CD-CP00 Blade. The PZ-BS11 is installed in the
expansion slot of the Expansion Chassis, which does not have a CD-CP00
Blade.
The EXIFU cable connects the Controlling Chassis and its PZ-BS10
interface to the second, third, and fourth PZ-BS11 interface.
Use only the CAT 5 cables provided by NEC to make the connections
between the Controlling and Expansion Chassis.
The PZ-BS10 provides:
Communication Processor Interface for data handling through
Communication Channel (24 slots maximum)
64 Channels for Telephony Resource (e.g., DTMF Tone Receiver,
Call Progress Tone Detector, MFC Tone Receiver, Caller ID Receiver,
Caller ID Signal Sender)
DSP Resource Management
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-24
2.5.4.1 Connector Pin-Out on the PZ-BS10/PZ-BS11
RJ-61 Cable Connector
PZ-BS10 – CN2, CN3, CN4
PZ-BS11 – CN3
Pin No.
Connection
1
HW_UP(+)
2
HW_UP(-)
3
HW_DWN(+)
4
FS(+)
5
FS(-)
6
HW_DWN(-)
7
CK8M(+)
8
CK8M(-)
Table 3-1 PZ-BS10/PZ-BS11 Connector Pin-Out
2.5.4.2 Install the PZ-BS10 Expansion Base Blade in the CHS2U
Controlling Chassis
Do not remove or install this blade with the power on.
1. Ensure the chassis is powered down.
2. Locate the door positioned on the left end (expansion bay) of
the Controlling Chassis.
Figure 3-28 PZ-BS10 Expansion Bay in Controlling Chassis
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-25
3. From the left side of the chassis, pull cover outward to
expose the expansion bay.
Figure 3-29 Open Base Chassis Cover
4. Pull the cover toward you to remove.
Cover must be removed prior to installation of PZ-BS10
blade.
5. Align the PZ-BS10 blade with the guides located in the
expansion bay.
Figure 3-30 PZ-BS10 Blade Guides
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-26
Figure 3-31 PZ-BS10 Components
6. Slide the PZ-BS10 blade into the chassis until resistance
(back plane) is felt.
Figure 3-32 PZ-BS10 Blade in Expansion Bay
7. Gently push until the blade seats and install the supplied
retaining screw.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-27
8. Align the door tabs with hinges and reattach the cover.
Figure 3-33 PZ-BS10 Blade Installed
9. Close the PZ-BS10 cover.
Figure 3-34 PZ-BS10 Installed (Cover Closed)
2.5.4.3 Install the PZ-BS11 Expansion Blade in the CHS2U
Expansion Chassis
.For the Expansion Chassis to function, the PZ-BS10 blade
must be installed in Controlling Chassis.
Do not remove or install this blade with the power on.
1. Ensure the chassis is powered down.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-28
2. Locate the door positioned on the left end (expansion bay) of
the Expansion Chassis.
Figure 3-35 PZ-BS11 Expansion Bay in Expansion Chassis
3. From the left side of the chassis, pull cover outward to
expose the expansion bay.
Figure 3-36 Open Expansion Chassis Cover
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-29
4. Pull the cover toward you to remove..
Cover must be removed to install PZ-BS11 blade.
5. Align the PZ-BS11 blade with the guides located within the
expansion bay.
Figure 3-37 PZ-BS11 Blade Guides
6. Slide the PZ-BS11 blade into the chassis until resistance
(back plane) is felt.
Figure 3-38 PZ-BS11 Blade Guides in
Expansion Chassis
7. Gently push until the blade seats and install the supplied
retaining screw.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-30
8. Align the door tabs with hinges and reattach the cover.
Figure 3-39 PZ-BS11 Blade Installed
9. Close the PZ-BS11 blade cover.
Figure 3-40 PZ-BS11 Blade Installed (Cover Closed)
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-31
2.5.4.4 Connect the Controlling and Expansion Chassis
Installment of the PZ-BS10 blade and PZ-BS11 blade(s)
must be completed prior to installation of the provided (CAT
5) expansion cabling.
Figure 3-41 PZ-BS11 Blade Installed (Cover Closed)
1. Ensure Controlling and Expansion chassis are powered
down.
2. Using the NEC provided CAT5 straight-through cable(s),
attach one end to each Expansion Chassis CN2 connector
on the PZ-BS11 blade (see Figure 3-42 System Expansion
Cabling on page 3-32. Attach the opposite end to the CN2,
CN3 or CN4 connector on the PZ-BS10 of the Controlling
Chassis.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-32
Figure 3-42 System Expansion cabling
3. Repeat for additional Expansion Chassis.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-33
2.5.5
Install 19” Chassis Grounding
From the factory, the SG, ETH and PBXG grounds are located inside the
chassis and are connected to the FG ground (frame ground) on the back
of the chassis.
Each chassis (CHS2U) in the system must be grounded separately using
the procedure listed below.
1. Ensure each Chassis is powered down and unplugged.
2. Ground each chassis by connecting a 14 AWG wire from the FG lug
on the back side of the chassis to an electrical service ground (such
as a cold water pipe).
Figure 3-43 Chassis Grounding Lug
2.5.6
Install 19” Chassis Grounding on Multiple Chassis (Optional)
From the factory, the SG, ETH and PBXG grounds are located inside the
chassis and are connected to the FG ground (frame ground) on the back
of the chassis.
Each chassis (CHS2U) in the system must be grounded separately using
the procedure listed below.
1. Ensure all Controlling and Expansion Chassis are powered down and
unplugged.
2. Ground each chassis by connecting a 14 AWG wire from the FG lug
on the back side of the chassis to an electrical service ground (such
as a cold water pipe).
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-34
Figure 3-44 19” Chassis Grounding Lug (Multiple-Chassis)
2.5.7
Install AC Power Cords
1. Locate the supplied AC power cord and attach to the AC Inlet located
on the back of the Controlling Chassis.
Figure 3-45 Install the AC Power Cord
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-35
2.5.8
Install AC Power Cords on Multiple-Chassis (Optional)
1. Locate the supplied AC power cords and attach to the AC Inlets
located on the back of the Controlling and Expansion Chassis.
AC Power Cord
to AC Inlets
Figure 3-46 Install 19” the AC Power Cords (Multiple-Chassis)
2.5.9
Install Additional Blades
Refer to Chapter 4, 2.1 Installation and Safety Precautions on page 4-3.
2.5.10
Apply Power to the 19” Chassis
Refer to Chapter 4, 2.6 Powering Up the SV8100 on page 4-8.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-36
SECTION 3 BATTERY CONNECTION
There are two types of battery connection to provide battery life in the event of a
power failure, the internal battery and an external battery with CHS LARGE BATT
BOX.
3.1 Installing the Internal Batteries
An internal battery source using two batteries can be installed using the CHS2U
BATT MTG KIT (mounting kit) and CHS2U BATT CABLE INT (internal cabling).
CHS2U BATT MTG KIT (Backup time = 10 Minutes/24 Terminals)
1.
Ensure the chassis is powered down.
Ensure the CHS2U chassis is powered OFF.
2.
Disconnect AC power and grounding cable from rear of chassis.
3.
Remove screws from battery access panel on rear of chassis. Refer to Figure
3-47 Removing Battery Access Panel.
Figure 3-47 Removing Battery Access Panel
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-37
4.
Remove access panel containing the fan. Refer to Figure 3-48 Removing
Access Panel and Figure 3-49 Access Panel Removed.
Figure 3-48 Removing Access Panel
Figure 3-49 Access Panel Removed
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-38
5.
Using tie wraps, secure CHS2U BATT CABLE INT in cable guide bracket (refer
to Figure 3-50 Installing Cable Guide).
Figure 3-50 Installing Cable Guide
6.
With supplied screw, install cable guide in chassis (refer to Figure 3-51
Installing Cable Guide).
Figure 3-51 Installing Cable Guide
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-39
7. Install two 2.3 AH-12V batteries (locally procured) into the CHS2U BATT MTG
KIT (refer to Figure 3-52 Installing Two Batteries).
The first battery must be installed on the left side, then slid to the right due
to an installation tab on the mounting kit.
Figure 3-52 Installing Two Batteries
8.
Using the supplied screws, secure the brackets to the CHS2U BATT MTG KIT
(refer to Figure 3-52 Installing Two Batteries on page 3-39).
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
Installing the SV8100 Chassis
3-40
9.
Connect the provided battery cables to the batteries (refer to Figure 3-53
Installing Battery Cable).
Figure 3-53 Installing Battery Cable
10. Connect CHS2U BATT CABLE INT to battery connector (refer to Figure 3-54
Connecting CHS2U BATT CABLE INT).
Figure 3-54 Connecting CHS2U BATT CABLE INT
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn
System Hardware Manual
3-41
11. Install CHS2U BATT MTG KIT into CHS2U chassis and tighten the retaining
screws (see Figure 3-55 Installing Battery Tray into CHS2U Chassis).
Figure 3-55 Installing Battery Tray into CHS2U Chassis
12. Reinstall access panel containing the fan and secure with supplied screw (refer
to Figure 3-56 Installing the Access Panel).
Figure 3-56 Installing the Access Panel
13. Connect grounding and AC power cable.
CHUYÊN CUNG CẤP TỔNG ĐÀI NEC
http//vietpro.com.vn