Clear-Com RM-702-IM Operation & User’s Manual
File Specifications
| Brand: | Clear-Com |
| Category: | Intercom System |
| Model: | RM-702-IM (Operation & User’s Manual), pr6orOAAvuRUg |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 43 pages |
Download PDF
Download Clear-Com RM-702-IM Manual (43 pages)Read Online:
Read the Clear-Com RM-702-IM Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
User Guide| RM-702/RM-802-IM
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Only use attachments/accessories specified by the manufacturer. 10. Use only with the cart, stand, tripod, bracke ...
User Guide| RM-702/RM-802-IM
Engineers, or in the case of project installations, once the Project Team has completed the hand-over to the Support Centers. 6.3 Return Material Authorization Policy a. Authorizations: All products returned to Clear-Com or a Clear-Com Authorized Service Partner must be identified by a Return Material Authorization (RMA) number. b. The Customer will be provided with an RMA number upon contacting Clear-Com Sales Support as instructed below. c. The RMA number must be obtained from Clear-Com via phone or email prior to returning product to the Service Center. Product ...
User Guide| RM-702/RM-802-IM
3.7.3 Internal IFB Operation To use either channel A or B as an IFB feed, connect the program source to the program input (as described in the previous section) and set the Program Interrupt A (or B) DIP switch to the on position. The program will now be interrupted whenever there is a call signal present on channel B. If there are multiple RM-702s in the system, the program should only be fed into one of the RM-702s. To interrupt the IFB program automatically when a talk rather than a call signal is active on channels A or B, you must reset an internal jumper as d ...
User Guide| RM-702/RM-802-IM
Europe, the Middle East and Africa: Hours:0800 - 1700 GMT + 1 Days:Monday - Friday Tel:+ 44 1223 815000 Email:[email protected] iv. Note: AWRs are not available for UHF WBS Analog wireless intercom systems. UHF WBS Analog wireless intercom systems out-of-box failures must be returned to Clear-Com for repair. v. Note: Out-of-box failures returned after 90 days will be repaired and not replaced unless approved by Clear-Com Management. vi. Note: AWRs are not available after 90 days of receipt of product unless an AWR Warranty Extension is purchased at the ...
User Guide| RM-702/RM-802-IM
Table of contents 1 Compliance 6 2 Operation 9 2.1 Introduction 9 2.2 The Clear-Com Concept 9 2.3 Description 10 2.4 Operation 11 3 Installation 14 3.1 Installation Overview 14 3.2 Description of Front panel Connectors 17 3.3 Headset Connector (Front Panel) 17 3.4 Description of Rear Panel Connectors 18 3.5 Description of Options and Adjustments 19 3.6 Typical System Applications 24 3.7 Actual Applications 26 4 Maintenance 34 4.1 Introduction 34 5 Technical Specifications 35 5.1 RM-702/RM-802-IM Two-Channel Station 35 6 Technical Support and Repair Policy 39 6.1 Te ...
User Guide| RM-702/RM-802-IM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 “ACCESSORY” CONNECTOR DB-15F Power (+30 VDC) GND – Program Input + Program Input Viewed from the rear of the unit 1. Connect a balanced input to pins #8 and #15 with the shield connected to pin #7. 2. To connect an unbalanced input, connect the signal to pin #8 and connect the shield to pins #15 and #7. l Connecting Party-Line Products As Program Sources: If other Clear- Com products (such as an AC-701 telephone interface) are to be used as a program source directly, use the following interconnection cable. Pin #14 ...
User Guide| RM-702/RM-802-IM
3 Installation This section discusses the installation of the RM-702/RM-802-IM in an intercom system including typical applications, overall installation theory, detail of each connector, and adjustments. 3.1 Installation Overview This section describes the Clear-Com concept of intercom line connection. The following subjects are discussed: l Intercom line connection l Line termination l Station powering l Cable considerations 3.1.1 Intercom Line Connection The RM-702/RM-802-IM provides male and female XLR-3 connectors for each intercom line, which are looped throu ...
User Guide| RM-702/RM-802-IM
Document reference RM-702/RM-802-IM User Guide 399G260 Rev A Legal disclaimers Copyright © 2018 HME Clear-Com LtdHME Clear-Com Ltd All rights reserved Clear-Com, the Clear-Com logo, and Clear-Com Concert are trademarks or registered trademarks of HM Electronics, Inc. The software described in this document is furnished under a license agreement and may be used only in accordance with the terms of the agreement. The product described in this document is distributed under licenses restricting its use, copying, distribution, and decompilation / reverse engineering. N ...
Clear-Com RM-702-IM user guide recommended for: Encore, RS-601, Tempest 900, HelixNet Partyline, HelixNet.
⚠️ Download Safety
The Intercom System Operation & user’s manual (43 pages) is completely safe to download (last scan date: 28/01/2026).
Related PDF Instructions for Clear-Com RM-702-IM:
-
Clear-Com TEMPEST 2400 Intercom System Operation & user’s manual
TEMPEST 240016 -
Clear-Com EclipseHX Intercom System Upgrade manual supplement
EclipseHX16 -
Clear-Com ICS-22 Speakers Instruction manual
ICS-2244 -
Clear-Com HME DX410 Intercom System Operation & user’s manual
HME DX41038 -
Clear-Com HelixNet Partyline Intercom System Operation & user’s manual
HelixNet Partyline285 -
Clear-Com trilogy Mercury Conference System Quick start manual
trilogy Mercury22
Intercom System Equipment: Frequently Requested
-
Anchor PortaCom Intercom System
21.11.2025Owner’s manual for the Anchor PortaCom Intercom System. The document guides users through specifications, connectivity options, regulatory notices, error codes.PortaCom, 12 -
Farfisa 1 FEV/4 Intercom System
26.04.2026Product manual for the Farfisa 1 FEV/4 Intercom System. The document highlights operating procedures and troubleshooting tips, system parameters, hardware instructions.1 FEV/4, 16 -
Bticino 367111 Intercom System
14.12.2025Installation and operation manual for the Bticino 367111 Intercom System. It contains information on security instructions, warranty information, setup guidelines, technical specifications.367111, 28 -
Toa DT-E70 Intercom System
17.11.2025Step-by-step user manual for the Toa DT-E70 Intercom System. This guide includes compatibility information, firmware updates, maintenance, startup procedures.DT-E70, 22 -
Elvox 3300 Camcorder
05.05.2026User support manual for the Elvox 3300 Camcorder. It covers regulatory notices, setup validation, system setup.3300, 12 -
HM Electronics DX121 Intercom System
14.04.2026Installation instructions for the HM Electronics DX121 Intercom System. It includes troubleshooting procedures and device operation tips, component replacement, device overview.DX121, 39
Have some Questions about Clear-Com RM-702-IM Device?
Get valuable and actionable advices from other Clear-Com RM-702-IM device users. Describe your problem or question, regarding the using of RM-702-IM, in as much detail as possible, and other users will be able to answer you.