G Before using the appliance, read these “SAFETY PRECAUTIONS” thoroughly and operate in the correct way.

G The instructions in this section all relate to safety; be sure to maintain safe operating conditions. SAFETY PRECAUTIONS ............................................... 1 STANDARD PARTS ........................................................ 2 FLOW OF INSTALLATION.............................................. 2 INSTALLATION ............................................................... 3 SETTING......................................................................... 5 • EXPLANATION OF TERMS ......................................... 5 • NAME OF PARTS ......................................................... 6 • TURN ON THE POWER ............................................... 7 • SETTINGS .................................................................... 7 • REMOTE CONTROLLER SETTINGS .......................... 8 • INDOOR UNIT REGISTRATION ................................ 11 • FINAL STEP ............................................................... 13 • ERROR CODE ........................................................... 14 CAUTION This mark indicates procedures which, if improperly performed, might possibly result in personal harm to the user or damage to property. G Do not wire the remote controller cord and the bus wire together with or parallel to the connection ca- bles, transmission cords, and power supply cords of the indoor and outdoor units. It may cause erro- neous operation. G Do not expose the controller directly to water. G Do not operate the controller with wet hands. G Do not touch the switches with sharp objects. G Always turn off the electrical breaker whenever cleaning the controller, the air conditioner or the air filter. CONTENTS Group Remote Controller (UTB-*D*) INSTALLATION INSTRUCTION SHEET (PART NO. 9374707034) For authorized service personnel only. WARNING This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user. G For the air conditioner to operate satisfactorily, install it as outlined in this installation instruction sheet. G Do not turn on the power until all installation work is complete. G Installation work must be performed in accordance with national wiring standards by authorized personnel only. Let the customer keep this installation instruction sheet because it is needed when the air conditioner or remote controller is serviced or moved. G Check the condition of the installation stand for damage. G Ensure that any electronic equipment is at least one meter away from the controller. G Avoid installing the controller near a fireplace or other heating apparatus. G When installing the controller, take precautions to prevent access by infants. G Do not use inflammable gases near the controller.

The following installation parts are supplied. Use them as required.

Q’ty 1 4 Application Use for air conditioner operation Use this for writing the names of the indoor units that have been regis- tered. Name and Shape Group remote controller Label Q’ty 2 1 Application For installing the remote controller For remote controller and remote controller cord binding Name and Shape Tapping screw (M4 × 16 mm) Binder * Use of this product requires a special convertor and connection cable. These are provided as service parts, so please contact authorized service personnel. FLOW OF INSTALLATION The following is the flow of the installation of Group remote controller. • INSTALLATION • SETTING INSTALLING THE REMOTE CONTROLLER SETTING THE DIP SWITCH WIRING TURN ON THE POWER REMOTE CONTROLLER SETTINGS INDOOR UNIT REGISTRATION ○ ○ ○ ○ ○ ○ ○ ○Refer to page 4 ○ ○ ○ ○ ○ ○ ○ ○Refer to page 4 ○ ○ ○ ○ ○ ○ ○ ○Refer to page 3 ○ ○ ○ ○ ○ ○ ○ ○Refer to page 7 ○ ○ ○ ○ ○ ○ ○ ○Refer to page 8 ○ ○ ○ ○ ○ ○ ○ ○Refer to page 11 • Setting the Group remote controller address • Time Display Settings • Timer Operation Settings • Temperature Range Settings • Temperature Display Settings

Hole × 2

Hole × 3 4.5 (3/16) 4.5 (3/16) 6 (1/4) 30 (1-3/16) 33.5 (1-5/16) 23 (29/32) 120 (4-3/4) 120 (4-3/4) 17 (11/16) When connecting the Group remote controller and Convertor, use the following wiring. Use Remote controller cord Size 0.33 mm2 (AWG22) Wire type Shield cable Remarks Polar 3-core * We recommend that you purchase our service parts for the remote controller cord. Contact service personnel to purchase this. Unit: mm (in.) 2. WIRING • Total remote controller cord length: MAX. 100 m (328 ft.) (1) When connecting one Group remote controller Remote controller cord Convertor Group remote controller CAUTION • Match the terminal number for the Group remote con- troller and the number on the terminal for the Convertor when the connection is made. (See Fig. 2 for the location of the Group remote control- ler terminal number.) • Do not route the remote controller cord near a source of electromagnetic interference. (2) When multiple Group remote controllers are connected (multiple Group remote controllers cannot be connected with the J-series.*) • A maximum of four Group remote controllers can be connected with one Convertor. • Use of a terminal box is recommended when a junction is made in the wiring. Convertor Remote controller cord Group remote controller Convertor Remote controller cord Group remote controller * It is a J-series model when the model name of the indoor unit ends in “R.” 1 1 2 2 3 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3

Open the operation panel on the front of the remote controller,

remove the two screws indicated in the right figure and then, re- move the front case of the remote controller. NOTES When installing the remote controller, remove the connector from the front case. The wires may break if the connector is not removed and the front case hangs down. When installing the front case, connect the connector to the front case. G When remote controller cord exposed 1) Make two horizontal or two vertical holes in the mounting surface (wall, etc.) to install the remote controller. (Fig. 2) 2) Use a tool to cut away the thin area on the upper center of the front case (indicated by in Fig. 1). 3) Connect the remote controller cord to the remote controller terminal board specified in Fig. 2. 4) Wrap the connector and remote controller cords with vinyl tape or some other type of insulation as shown in Fig. 2. 5) Clamp the remote controller cord with the binder as shown in Fig. 2. 6) Cut off the excess binder. 7) Install the rear case to the wall, etc., with two screws (ø4 × 16). (Fig. 3) NOTES Step 4) will be noticed by customers, so do it with particular care. 3. INSTALLING THE REMOTE CONTROLLER CAUTION • Do not touch the group remote controller Circuit board and Circuit board parts directly with your hands. • When working with the wiring, be careful not to scratch or damage the wires. Fig. 1 Front case (back side) Rear case Connector Screws 63.5 (2-1/2) 63.5 (2-1/2) 83.5 (3-9/32) Fig. 2 1.12V (Red) 2.Signal (White) 3.COM (Black) Binder Hole Group remote controller Insulation G When remote controller cord embedded 1) Embed the remote controller cord and box. 2) Pass the remote controller cord through the hole in the rear case and connect the remote controller cord to the remote controller terminal board specified in Fig. 2. 3) Wrap the connector and remote controller cords with vinyl tape or some other type of insulation as shown in Fig. 2. 4) Clamp the remote controller cord sheath with the binder as shown in Fig. 2. 5) Cut off the excess binder. 6) Install the rear case to the wall, box, etc., with two screws (ø4 × 16). Fix the two screws in either horizontal or vertical position. (Fig. 3) Fig. 3 [Example] Remote controller cord Rear case Box Screws Connector 4. SETTING THE DIP SWITCH Set DIP switch 1 to ON to enable the memory backup. • Memory backup setting If there is a power failure when the memory backup is enabled, the settings stored in the memory will be saved. ON ON OFF 1 2 DIP Switch Front case (back side) NO. SW state OFF ON 1 # Invalidity Validity 2 # Fixed at OFF DIP-Switch (# Factory setting) 7 (9/32) (9/32) (9/32) 7 7 1.12V (Red) 2.Signal (White) 3.COM (Black)

EXPLANATION OF TERMS

Indoor unit System Refrigerant system Refrigerant pipe Convertor Outdoor unit Group remote controller Transmission line Controller line Wireless remote controller Wired remote controller Remote controller group Controller related items G System: This is all of the indoor units, outdoor units and controller units connected by the same transmission line. G Refrigerant system: [Not for J-series*] This is a system composed of indoor and outdoor units connected by the same refrigerant pipe. G Remote Controller group: [Not for J-series*] This is the smallest unit controlled by group remote controller. This is a group of indoor units that have been connected with one controller line. Indoor / Outdoor unit setting (on the Circuit board) G Refrigerant circuit address (0~99): [Not used for J-series*] This is the ID individually assigned to each refrigerant system and is used for control. G Indoor unit address (0~63): [J-series* uses 0-7] This is the ID individually assigned to each indoor unit and is used for control. G Remote controller address (0~15): [Not used for J-series*] This is the ID individually assigned to the indoor units forming each remote controller group and is used for control. Group remote controller setting G Group remote controller address (0~3): [J-series* uses “0” only] This is the ID individually assigned to each group remote controller and is used for control. * It is a J-series model when the model name of the indoor unit ends in “R.”

G With cover closed

Indoor Unit Name Labels G With cover open Setting Display Day Display Timer and Clock Display Timer Mode Display Timer Mode (DELETE) Button DAY Button Set Time Button PROGRAM (CLOCK ADJUST) Button ENTER Button Transmission Display Operation Lock Display ON/OFF Display Fan Speed Display Temperature Display Operation Mode Display Start/Stop Button Select Button Fan Control Button Master Control Button Set Temperature Button Timer and Clock Display and setting Displaying the Status and Controlling indoor units NAME OF PARTS Indoor Unit Operation Indicators Operation Lamp ALL OFF Button ALL ON Button ALL TIMER Button ON/OFF Button

TURN ON THE POWER

Turn on the power Once the installation and wiring has been completed, use the following procedure to turn on the power. 1. Turn on the power for all connected indoor units. 2. Turn on the power for all connected outdoor units. 3. Turn on the power for all connected convertor of group remote controllers. For J-series 1. Turn on the power for all connected indoor units and outdoor units. 2. Turn on the power for all connected convertor of group remote controllers. Wait for one minute or more after turning on the power before performing the next section. SETTINGS Switching to the Settings Screen Initial Screen Flashing Flashing 1 Settings Hold down the Set Time buttons and simultaneously for two seconds or more to start the Settings. 2 Press the Set Temperature button to select the item to be set. Settings : REMOTE CONTROLLER SETTINGS → Page 8 : INDOOR UNIT REGISTRATION → Page 11 , , , , , : Forbidden 1-6 G To complete Settings Hold down the Set Time buttons and simultaneously for two seconds or more to complete the settings. NOTES When there is a display other than the initial screen, it is possible that an error has occurred. Please consult authorized service personnel in such cases. ( ) Turn on the power Error code (Refer to page 14.)

REMOTE CONTROLLER SETTINGS

Remote Controller Settings Initial Screen Remote Controller Settings G To select the setting DAY Press the DAY button to select the item to be set. Settings : Setting the Group remote controller address → Page 8 , : Forbidden → Page 9 : Time Display Settings → Page 9 : Timer Operation Settings → Page 9 : Temperature Range Settings → Page 10 : Temperature Display Settings → Page 10 Setting the Group remote controller address To set the Group remote controller address 1 Reverse Advance Check that it is . Group remote controller address Press the Set Time buttons to set the Group remote controller address. * For each convertor, make the settings in order starting with “0” according to the number of Group remote controllers connected. * Set to “0” for the J-series. 2 Press the ENTER button. Check that and flash for two seconds. 3 DAY Press the DAY button to move to “ Forbidden.”

To move to the following settings

G Forbidden Press the DAY button to move to “ Time Display Settings. ” G Forbidden Press the DAY button to move to “ Setting the Group remote controller address. ” Time Display Settings (This switches the time display.) To switch the time display 1 Decrement Increment Press the Set Time buttons to set the time display. Check that it is . Time Display Setting or : 24 Hour Clock Display : 12 Hour Clock Display 1 : 12 Hour Clock Display 2 2 Press the ENTER button. Check that and flash for two seconds. 3 Press the DAY button to move to “ Timer Operation Settings. ” Timer Operation Settings (This enables/disables the weekly timer.) To enable/disable timer operation Press the Set Time buttons to set the timer operation setting. Check that it is . Timer operation setting 2 Press the ENTER button. Check that and flash for two seconds. 3 Press the DAY button to move to “ Temperature Range Settings.” 1 Decrement Increment Enabled Disabled DAY DAY DAY

Temperature Range Settings (This changes the temperature range.)

To set the temperature range Press the Set Time buttons to set the temperature range. Check that it is . Temperature range setting 2 Press the ENTER button. Check that and flash for two seconds. 3 Press the DAY button to move to “ Temperature Display Settings.” 1 Decrement Increment G The temperature range set for heating operation is different. DAY Temperature Display Settings (This switches the display between Celsius and Fahrenheit.) To switch the temperature display Press the Set Time buttons to set the temperature display. Check that it is . Temperature display setting 2 Press the ENTER button. Check that and flash for two seconds. 3 Press the DAY button twice to move to “ Setting the Group remote con- troller address.” Celsius Fahrenheit 1 Decrement Increment DAY Moving to “ Indoor Unit Registration” To move to indoor unit registration Pressing once moves to indoor unit registration Pressing seven times moves to indoor unit registration Press the Set Temperature button once or press the Set Tem- perature button seven times to move to indoor unit registra- tion. : 10 °C – 30 °C (48 °F – 88 °F) : 16 °C – 30 °C (60 °F – 88 °F)

INDOOR UNIT REGISTRATION

G A maximum of 8 remote controller groups can be registered for a Group remote controller. G Remote controller groups in 2 different refrigerant systems that are connected to a single convertor can be registered. G The remote controller groups registered can be monitored and controlled. G When registering indoor units to each of the buttons, consult the customer. Indoor unit registration screen 1 2 3 4 Refrigerant circuit address (Not shown with J-series) Registration position Indoor unit address Remote controller address (Not shown with J-series) Indoor Unit Registration Methods G Manual registration G Automatic registration (J-series only) Manual Registration To register indoor units manually 1 G Registration position selection Press the Select button to select the position for registering the indoor unit 2 G Refrigerant circuit address selection (Not used for J-series) Press the DAY button to select the refrigerant circuit address for the indoor unit being registered. • Hold down a Set Time button to scroll through the addresses quickly. DAY 3 G Indoor unit address selection Press the Set Time buttons to select the indoor unit address for the indoor unit being registered. • Hold down a Set Time button to scroll through the addresses quickly. Decrement Increment For J-series When a remote controller group made up of a single indoor unit is registered, select the indoor unit address. Initial Screen See EXPLANATION OF TERMS on page 5 for explanations of each address.

When a remote controller group made up of multiple indoor units is registered, the remote controller address and the

indoor unit address are selected. Decrement Increment G Remote controller address selection Indoor unit address ex.: Refrigerant circuit address “ ”, remote control- ler address “ ” * The refrigerant circuit address is the same as the address for the indoor unit set first (remote controller address “ ”) and cannot be changed. 1. Press the PROGRAM (CLOCK ADJUST) button to select the remote controller address of the indoor unit being registered. 2. Press the Set Time buttons to select the indoor unit address of the indoor units in the same remote controller group that is being registered. 3. Repeat steps 1 and 2 to register all the indoor units in this remote controller group. 5 Press the ENTER button to register the selected indoor unit. Check that the refrigerant circuit address, indoor unit address, , and flash (up to two minutes). • Press the Timer Mode (DELETE) button during this time to cancel the registration. 6 Repeat steps from 1 to 5 to register other indoor units. G To delete the registered settings 1. Press the Timer Mode (DELETE) button during steps 2 to 4 to reset the contents of the registration. (If the currently displayed indoor unit is part of a remote controller group with multiple units, only the settings for this indoor unit are reset.) 2. Press the ENTER button to delete the contents of the registration. Automatic registration (J-series only) To register indoor units automatically CLOCK ADJUST Press the PROGRAM (CLOCK ADJUST) button to start automatic registration. Automatic registration completes in approximately two minutes. NOTES (1) Be careful not to end the settings or switch the indoor unit before pressing the ENTER button. Otherwise, the changed settings will be lost. (2) If is displayed during the registration of an indoor unit, the Group remote controller address, refrigerant circuit address, or indoor unit address may incorrect. Check again. Remote controller address Refrigerant circuit address G Indoor unit address selection Flashing

Moving to “

REMOTE CONTROLLER SETTINGS” To set the remote controller Press the Set Temperature button seven times or press the Set Temperature button once to move to remote controller settings. Completing All of the Settings To complete Settings G When the remote controller settings and indoor unit settings are complete Hold down again the Set Time buttons and simultaneously for two seconds or more to complete Settings. FINAL STEP To apply the label Write the name of the indoor unit or the room where it is installed on the label, and apply it to the Group remote controller. • Consult the customer about the names to be written on the label. • Explain to the customer about the indoor units that have been registered to each button. Label (Standard parts) 84 × 21 (3-9/32 × 13/16) Pressing seven times moves to remote controller settings Pressing once moves to remote controller settings

Model information abnormal

Model information abnormal – 03 Microcomputer communication error Microcomputer communication error Microcomputer communication error 04 Power supply frequency abnormal Power supply frequency abnormal – 05 – – Parallel communication error 06 EEPROM access error EEPROM access error EEPROM access error 07 EEPROM deletion error EEPROM deletion error – 08 – – – 09 Compressor 1 error Room temperature thermistor error – 0A Compressor 2 error Heat exchanger thermistor (middle) error – 0b Compressor 3 error Heat exchanger thermistor (inlet) error – 0C – Heat exchanger thermistor (outlet) error – 0d Discharge temperature thermistor 1 error Blower temperature thermistor error – 0E Discharge temperature thermistor 2 error – – 0F Discharge temperature thermistor 3 error – – 10 Outdoor temperature thermistor error – – 11 Heat exchanger inlet thermistor 1 error Drain abnormal – 12 Heat exchanger inlet thermistor 2 error Room temperature abnormal – 13 Heat exchanger inlet thermistor 3 error Indoor unit fan error – 14 Heat exchanger outlet thermistor 1 error – – 15 Heat exchanger outlet thermistor 2 error – – 16 Heat exchanger outlet thermistor 3 error – – 17 Suction temperature thermistor error – – 18 – Standard wired remote control communication error – 19 Discharge pressure sensor error – – 1A Liquid pressure sensor error – Address setting error 1b Suction pressure sensor error – – 1C Oil sensor error – Connection error 1d – – System error 1E – – – 1F Transmission error Transmission error Transmission error 20 – – – 21 Discharge temperature 1 error – – 22 Discharge temperature 2 error – – 23 Discharge temperature 3 error – – 24 High-pressure error – – 25 Low-pressure error – – 26 – – – 27 Oil recovery error – – 28 Pump down error – – ERROR CODE The air conditioning system must be inspected if “E✽:✽✽” (error code) appears on the Timer and Clock Display, or the operation lamp is flashing. The following explains the meaning of each of the error codes. Model code Error code Model code : Outdoor unit : Indoor unit : Group remote controller : Convertor Group remote controller error Convertor error Outdoor unit error Indoor unit error Error Code