Accu-Chek Softclix Instructions For Use

Specifications

Brand: Accu-Chek
Category: Personal Care Products
Model: Softclix (Instructions For Use)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Accu-Chek Softclix Instructions For Use online using the built-in PDF viewer.

Text of the manual

➋ Firmly insert a new ACCU-CHEK Softclix lancet in the lancet holder

until it snaps into place. ➌ Twist the protective cap on the lancet several times and pull gently to remove it. ➍ Snap on the cap after lining up the notches. The cap snaps easily into place. ➎ Select the desired depth setting as instructed in the section “Selecting the Depth”.Then, press the plunger on the end of the device all the way down, and you will hear a “click.” When the device is ready, you will see a yellow dot appear and remain in the center of the clear release button. ➏ Now, wash your hands and dry them thoroughly. Also warm the fingers to increase blood flow. If you are using alcohol wipes, make sure your finger is completely dry before continuing. ➐ Grasp your finger near the area to be pricked and gently massage for three seconds. ➑ Hold the lancing device firmly against the side of your fingertip, then press the release button. Gently squeeze your fingertip to get a small drop of blood. The best place to test on the fingertip is the side, because it has the best blood supply, yet allows for the least painful fingerstick. Any finger may be used for a fingerstick. Lancet Instructions for Use The ACCU-CHEK Softclix lancing device uses ACCU-CHEK Softclix lancets to obtain a drop of blood from the fingertip. The penetration depth can be selected to match any type of skin. This cap is for fingertip testing only. The clear cap is for testing on sites other than the Fingertip (AST). Do not use the clear cap for fingertip testing. Note: The ACCU-CHEK Softclix cap was not designed to be replaced after each use. The ACCU-CHEK Softclix lancing device is intended for use by a single person and is not suitable for testing different persons with the same device as this may lead to infections. Selecting the Depth The depth on the ACCU-CHEK Softclix device may be adjusted by turning the Comfort Dial. The current depth selection is shown in the center of the depth indicator window. You can find the depth indicator window as a semi-circular cutout on the ejector. The ACCU-CHEK Softclix lanc- ing device offers 11 depth set- tings. The settings are shown in the depth indicator window by the numbers 1 to 5 with additional levels marked with dots to enable you to precisely adjust to your individual skin type. The higher the number visible in the depth indicator window, the greater the depth setting. Note: If you are using the ACCU-CHEK Softclix lancing device for the first time, start by selecting 1 or 2 to see if the amount of blood obtained is enough to perform a test. If your skin is calloused or thick, you may need to try a higher setting. ➊ To select the desired depth setting, turn the Comfort Dial so that the desired setting is in the center of the depth indicator window. ➋ Select a new depth setting by turning the Comfort Dial. The cap will snap into a new position, preventing any accidental change of the depth setting. Performing a Fingerstick ➊ Pull off the cap of the lancing device. If there is already a lancet in the device, remove it by sliding the ejector forward. Refer to the selection called “Removing the Lancet”. ➒ Apply the drop to the test strip you are using. ➓ Immediately remove used lancet. To avoid accidental injury, do not store lancet in device. Removing the Lancet ➊ To remove the lancet, pull off the cap of the ACCU- CHEK Softclix device. ➋ Hold the meter so the lancet points downward. Slide the ejector forward to release the lancet into a puncture- proof container. For least painful testing and to avoid infection, use a new lancet each time you perform a fingerstick. Getting Blood From A Site Other Than Your Fingertip Testing on sites other than the fingertip is referred to as alternate site testing (AST). These sites may be any of the following – palm, forearm, upper arm, thigh, or calf. We suggest the palm as the non-fingertip test site. Please refer to your test strip insert or your blood glucose meter’s owner’s booklet to see if your meter is designed to test blood glucose from sites other than your fingertip as well as for specific AST testing instructions. IMPORTANT – There is a delay (lag time) in the delivery of blood glucose to non-fingertip sites when compared to fingertip. Therefore, there is a potential for a significant difference between fingertip and AST results. The length of delay (lag time), is strongly impacted by lifestyle, foods eaten, or any other event having impact on blood glucose levels. It is important that people considering non-fingertip testing understand the following: ● Talk to your doctor if you are considering testing on other sites than your fingertip. ● AST testing is not recommended during periods of rapid decreases or increases in blood glucose levels. ▼ ▼ 0 5104076001(01) V1/R1 (black) – 2007-09 018035 Roche – RH 3109 – Frau Heiland Cap with Comfort Dial Depth Selection Ejector Release Button ▼ Protective Cover ▼ pi_05104076001_01_EnUs_420x216.indd 1 23.01.2008 14:04:25

● AST testing is not recommended for people with a history of recur-

rent hypoglycemia, who suspect their blood glucose is extremely low, or who are unaware of hypoglycemic events. ● NEVER ignore symptoms of high or low blood sugar. ● Do not change your treatment based on one result. ● If the AST reading does not match how you feel, perform a fingertip test to confirm your results. If your blood glucose still does not reflect the way you feel, contact your doctor. For more information on AST testing please contact ACCU-CHEK Customer Care Service Center at 1-800-858-8072. ➊ Wash the non-fingertip site with warm water. ➋ Make sure that you are using the clear cap specially designed for AST testing with the ACCU-CHEK Softclix lancing device. ➌ Adjust the clear cap to the highest setting. ➍ Press and hold the lancing device against a fleshy area on the AST site. Press the release button and continue to apply steady pressure to the site. Don’t be afraid to apply strong pressure to the area with the lancet device to get a good blood drop. Caring For Your Lancing Device ● Your lancing device requires very little care. ● Keep it away from extreme temperatures. ● Clean the outside of the lancing device regularly with 70% isopropyl (rubbing) alcohol. Let it air dry. ● Do not dip the lancing device in liquid. ● Do not use bleach to clean the lancing device or caps. Assistance Available If you need assistance, please contact ACCU-CHEK Customer Care Service Center toll-free, 24 hours a day, 7 days a week. We offer assistance in Spanish and many other languages. 1-800-858-8072 phone 1-800-858-8074 TDD/TYY (for the hearing impaired) Also Available from Roche ACCU-CHEK Softclix Lancets Cat. No. 971, 100/box Cat. No. 988, 200/box ACCU-CHEK Advantage Diabetes Care Kit Cat. No. 860 ACCU-CHEK Active Diabetes Care Kit Cat. No. 3184501 One (1) Year Warranty Roche warrants the ACCU-CHEK Softclix lancing device against defects in materials and workmanship for a period of one (1) year from the date of purchase. The liability of Roche under this warranty is limited to the repair or replacement, at Roche’s option, of all parts or materials proven to be defective. This warranty does not cover repair or replacement of ACCU-CHEK Softclix lancing devices which have been subjected to alteration, misuse, tampering, or abuse. THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED, OR STATUTORY. ROCHE DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Roche entire liability with respect to the ACCU-CHEK Softclix lancing device shall be the repair or replacement of nonconforming devices, at Roche option. In no case shall Roche be liable for incidental, indirect, special, or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. All inquiries about the ACCU-CHEK Softclix lancing device under the above warranty or service policy must be directed to ACCU-CHEK Customer Care Service Center by calling 1-800-858-8072. You will be informed of the procedure necessary for replacement. Please DO NOT return any device to Roche without authorization. IMPORTANT – Read carefully before use. Caution: A restricted license limits the use of this ACCU-CHEK Softclix lancing device. This ACCU-CHEK Softclix lancing device and its use are protected by U.S. Patent Nos. 4,924,879; 6,419,661; 7,077,828 and Re. 35,803. A license to use this ACCU-CHEK Softclix lancing device is only granted when ACCU-CHEK Softclix lancets are used as part of the ACCU-CHEK Softclix lancing device. Using the ACCU-CHEK Softclix lancing device indicates your acceptance of the restricted license to use the ACCU-CHEK Softclix lancing device with only ACCU-CHEK Softclix lancets. If you do not agree to the terms and conditions of the restricted license, you may return the unused ACCU-CHEK Softclix lancing device for a full refund. ACCU-CHEK Softclix lancets are high-precision components that are produced to the close tolerances required for satisfactory operation with the ACCU-CHEK Softclix lancing device driver. Use of any other lancet with the ACCU-CHEK Softclix lancing device driver may prevent or impair proper function of the ACCU-CHEK Softclix lancing device. Visit our website at www.accu-chek.com This product is covered by the following U.S. Patents: 4,924,879; 6,419,661; 7,077,828; D429,814; 6,464,649; and RE. 35,803. ACCU-CHEK ACTIVE, ACCU-CHEK ADVANTAGE and SOFTCLIX are trademarks of Roche. Roche Diagnostics GmbH 68298 Mannheim, Germany www.accu-chek.com Distributed in the U.S.A. by: Roche Diagnostics, 9115 Hague Road, Indianapolis, IN 46256, USA Made in Germany ©2007 Roche. All rights reserved. 0 5104076001(01) R1 (black) pi_05104076001_01_EnUs_420x216.indd 2 23.01.2008 14:04:26

Other Personal Care Products Manuals