B+B SmartWorx 4WSD9R Quick Start Manual

Text of the manual

You can perform a loopback test by connecting either

an RS-232 to RS-422/485 converter or a USB to RS- 422/485 converter to the 4WSD9R(4WSD9TB). Using HyperTerminal or a similar program, connect to the appropriate COM port. Remember to set the baud rate to 9600. Turn off HyperTerminal local echo. Start typing. If you can see the data you are typing, the loopback is successful. Loopback Test 7 Bias is provided by 4.7kΩ pull-up/down resistors on the Data-In lines. This value is adequate for most applications without termination. If another value is required, space is provided on the PC for through-hole resistor placement (R12, R21, R14, and R23). Biasing 8 Recommended Accessories DB9 Male to DB9 Female Cable, 1.8 m (6 ft) length # 9PAMF6 12VDC, 6W Power Supply, 2.5mm Plug, International AC Input # SMi6-12-P230-C1 1-888-948-2248 | Europe: +353 91 792444 advantech-bb.com 707 Dayton Road | PO Box 1040 | Ottawa, IL 61350 Phone: 815-433-5100 | Fax: 815-433-5109 www.advantech-bb.com | E-mail: [email protected] Fast and easy on the web: www.advantech-bb.com QUICK START GUIDE Document Number: 710-10715-00_r1_4WSD9x_4617qsg Before you begin, be sure you have the following: Models 4WSD9R, 4WSD9TB Port-Powered RS-232 to RS-485 Converter + RS-232/485 Isolated Converter (#4WSD9R or #4WSD9TB) + DB9 to DB9 Adapter Cable (not included) + 12VDC, 6W Power Supply (not included)

Models 4WSD9R & 4WSD9TB convert RS-232 signals to

RS-422/RS-485 and vice versa. RS-232 TD signals are converted to balanced RS-422 or RS-485 signals. RD RS- 422/485 signals are converted to RS-232. Table 2. RS-422/485 PINOUT PIN # SIGNAL 2 RD (A)- 3 TD (B) + 4 GND 6 GND 7 RD (B)+ 8 TD (A)- Table 1. RS-232 PINOUT PIN # SIGNAL 1 DCD 2 RD 3 TD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS RS-422-RS-485 3 Automatic Send Data Control 5 Unlike converters that require programming the hardware handshake signals to control RS-422/RS-422 operation, Models 4WSD9TB or 4WSD9R provide Automatic Send Data Control, enabling the driver only when transmitting: In RS-485 Modes, the RS-485 driver is enabled by circuitry which senses the RS-232 TD Input. In RS-485 Half-Duplex Mode, the receiver is enabled when not transmitting (Echo Off). In RS-485 Full-Duplex Mode, the receiver is always enabled. In RS-422 Full-Duplex Mode, the transmitter and receiver are always enabled. Table 3. SWITCH SETTINGS RS-485 2-Wire Half-Duplex SWITCH # POSITION 1 RS-485 2 Echo Off 3 2-wire 4 2-wire Table 4. SWITCH SETTINGS RS-485 4-Wire Full-Duplex SWITCH # POSITION 1 RS-485 2 Echo On 3 4-wire 4 4-wire Table 5. SWITCH SETTINGS RS-422 4-Wire Full-Duplex SWITCH # POSITION 1 RS-422 2 Echo On 3 4-wire 4 4-wire DIP Switch Settings 6 Mode Wiring Examples 4

Other Media Converter Manuals