Amprobe VPC-20 Instruction Manual

Specifications

Brand: Amprobe
Category: Measuring Instruments
Model: VPC-20 (Instruction Manual)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Amprobe VPC-20 Instruction Manual online using the built-in PDF viewer.

Text of the manual

Digital Voltage and Continuity Tester

Model VPC-20 Instruction Manual � Safety Information • Never use the tester if it or test leads appear damaged. • Never apply more than 600V DC or 600V AC rms. between any terminal and earth ground • When using the probes, keep your fingers behind the finger guard on the probes. • Turn off power to the circuit under test before cutting, desoldering, or breaking the circuit. Small amounts of current can be dangerous. • Use caution when working with voltage above 60V dc or 30V ac rms. Such voltages pose a shock hazard. Automatic Operation The tester automatically turns on when you short the two test probes or place the probes across a complete circuit.When turned on, the tester powers up in continuity mode. If a dc or ac voltage greater than about 4.0V is present across the inputs, the tester switches to dc or ac voltage mode.The tester automatically shuts down after approx. 4 minutes of inactivity. Continuity testing Turn off circuit power before testing. Beeper indicates shorts lasting 1 ms or longer. SHORT 10KΩ OPEN Specifications: Display: Large 1999 count LCD display with function and high voltage warning indication. Maximum Voltage Between any Terminal and Earth Ground: 600V dc; 600V ac rms, Over-voltage Category III 600V Safety: Complies with EN61010-1:1993 for use in over-voltage CAT III environments Pollution Degree: 2 For indoor use only EMC Regulations: EN50081-1, EN50082-1 Polarity: Automatic, (-)negative polarity indication. Over-range: “1” mark indication Low battery indication: The “BAT” is displayed when the battery voltage drops below the operating level Measurement rate: 2 times per second, nominal Continuity test: Audible threshold 0-10KW, Continuity beeper 2KHz Input Impedance: 400KΩ Temperature: 5 °C(41°F) to 40°C (104°F) Altitude: Operating: 2000m; Storage: 10,000m Relative Humidity: 80% for Temp up to 31C decreasing linearly to 50 % RH at 40C Pollution Degree: 2 For indoor use only Battery Type: AA (2) NEDA 15F or IEC R6 12V DC 240V AC Measuring Voltage Refer to Automatic Selection DC Voltage (Volts dc>4.0V) 600V dc maximum AC Voltage (Volts dc>4.0V) 600V ac maximum 50Hz to 400Hz Function Range Accuracy(%rdg.+digits) V AC(50Hz~400Hz) 600V +(2.9%+8) V DC 600V +(1.5%+2) Continuity test: Audible threshold 0~10KΩ,Continuity beeper 2KHz. Overload protection: AC/DC 600V Diminsions/wt.:215x96.3x37.5mm/312g

Replacing the Batteries

If the sign “BAT” appears on the LCD display, it indicates that the batteries should be replaced. Remove screws on the back cover and open the case. Replace the exhaust- ed batteries with new batteries. (AA(2);NEDA 15F or IEC R6) WARRANTY Congratulations! Your new instrument has been quality crafted according to quality standards and contains quality components and workmanship. It has been inspected for proper operation of all of its functions and tested by qualified factory technicians according to the long-established standards of our company. Your instrument has a limited warranty against defective materials and/or workmanship for one-year from the date of purchase provided that, in the opinion of the factory, the instrument has not been tampered with or taken apart. Should your instrument fail due to defective materials, and/or workmanship during this one-year period, a no charge repair or replacement will be made to the original pur- chaser. Please have your dated bill of sale, which must identify the instrument model number and serial number and call the number listed below: Repair Department ATP – Amprobe, TIF, Promax Miramar, FL Phone: 954-499-5400 800-327-5060 Fax : 954-499-5454 Website: www.amprobe.com Please obtain an RMA number before returning product for repair. Outside the U.S.A. the local representative will assist you. Above limited warranty covers repair and replacement of instrument only and no other obligation is stated or implied. P/N: ATP VPC-20Manual printed in China 2xAA Disconnect probes from Voltag. Do not over-tighten screws Miramara, Florida 33025 Tel: 954-499-5400 Toll Free: 800-327-5060 Fax: 954-499-5418

Other Measuring Instruments Manuals