Maple Systems HMI5000 Series Information Sheet

Text of the manual

. Maple Systems Inc., 808 134th Street SW, Suite 120, Everett, WA 98204-7333 – www.maplesystems.com

1036-0204 Page 1 of 4 Rev. 01, 12/03/2013 C O N T R O L L E R I N F O R M A T I O N S H E E T Maple Model(s) PLC or Controller HMI5000 Series Omron FINS/TCP (Ethernet) Summary Maple Systems’ HMI5000 Series Human/Machine Interface Terminals (Maple HMIs) communicate with devices that support the Omron FINS protocol. When configured with EZware, the Maple HMI is the master in a point-to-point single master, multiple slave format. Please refer to the Installation and Operations Manual for information on connecting multiple Maple HMIs to a single PLC port. Compatible PLCs Communications Cable The Maple HMI should be connected to the Ethernet port on the PLC. If the HMI is connected directly to the PLC, use a crossover cable from the HMI to the PLC. A list of communications cables offered by Maple Systems as well as cable assembly instructions to assist you in assembling your own communications cable are available on our website at www.maplesystems.com. WARNING If your communications cable is not wired exactly as shown in our cable assembly instructions, damage to the HMI or loss of communications can result. Family Model FINS/TCP Devices All

Phone: 425/745-3229 • Fax: 425/745-3429 • Email: [email protected] • www.maplesystems.com

1036-0204 Page 2 of 4 Rev. 01, 12/03/2013 Accessible PLC Memory Register Memory The following table lists the PLC’s register memory ranges that the Maple HMIs are able to access. Please note that your PLC’s memory range may be smaller or larger than that supported by these HMIs. The following register memory can be displayed in 16 or 32-bit format on the Maple HMI. (Note: d=decimal ) PLC Register Type Address Range Format PLC Register Description CIO 0-32767 ddddd Channel I/O W 0-32767 ddddd Work Area H 0-32767 ddddd Holding Area A 0-32767 ddddd Auxiliary Relay (Read Only) C 0-32767 ddddd Counter T 0-32767 ddddd Timer D 0-32767 ddddd Data Memory EM0-EMC 0-32767 ddddd Extended Memory (this Extended Memory resides in the PLC, and is different than the HMI’s EM areas) Discrete Memory The following table lists the PLC’s discrete memory ranges that the Maple HMIs are able to access. Please note that your PLC’s memory range may be smaller or larger than that supported by these HMIs. The following discrete memory is displayable in single-bit format on the Maple HMI. (Note: d=decimal, b=bit) PLC Bit Type Address Range Format PLC Bit Description CIO_Bit 000-3276715 dddddbb Channel I/O W_Bit 000-3276715 dddddbb Work Area H_Bit 000-3276715 dddddbb Holding Area A_Bit 000-3276715 dddddbb Auxiliary Relay (Read Only) D_Bit 000-3276715 dddddbb Counter T_Bit 000-3276715 dddddbb Timer C_Bit 000-3276715 dddddbb Data Memory C_Flag 0-4095 dddd Counter Flag T_Flag 0-4095 dddd Timer Flag

. Maple Systems Inc., 808 134th Street SW, Suite 120, Everett, WA 98204-7333

1036-0204 Page 3 of 4 Rev. 01, 12/03/2013 Important Memory Considerations If your PLC’s memory range is smaller than the range supported by the Maple HMIs, it is possible to configure the HMI to monitor a PLC memory address that does not exist. This can cause unpredictable results. When you configure the HMI please ensure that all selected PLC memory addresses are valid for your PLC model. Do not configure the HMI to write to any PLC memory address that should only be written to by the PLC. EZware Settings The following table lists the communications settings that must be configured in EZware. These settings can be found in the Edit-Set System Parameters menu under the Device tab. Please note:  The Recommended Settings column provides the recommended setting based upon the default settings most commonly used in the Omron devices.  The Options column lists EZware’s options; your PLC may not support every option Name Recommended Settings Options Important Notes Name: Omron (Ethernet – FINS/TCP) Description label HMI or PLC PLC Location Local Local, Remote Select Local if PLC directly connected to HMI, Remote if PLC connected thru another HMI PLC type: Omron (Ethernet – FINS/TCP) PLC I/F: Ethernet Ethernet

Phone: 425/745-3229 • Fax: 425/745-3429 • Email: [email protected] • www.maplesystems.com

1036-0204 Page 4 of 4 Rev. 01, 12/03/2013 Name Recommended Settings Options Important Notes Settings: IP Address: xxx.xxx.xxx.xxx 0.0.0.0- 255.255.255.255 Must match the controller port’s IP Address Settings: Port 9600 0-65535 Must be 9600. Settings: Timeout (sec) 1 0.1 to 25.5 Adjust if longer timeout is required Settings: Turn around delay (ms): 0 0-1000 Timeout period between OIT polls Settings: Send ACK Delay : 0 Not Applicable Settings: Parameter 1: 0 Not Applicable Settings: Parameter 2: 0 Not Applicable Settings: Parameter 3: 0 Not Applicable Setting: Use UDP: Unchecked Checked or Unchecked Must be unchecked. PLC default station no.: 0 0-255 Must match the controller’s setting. Interval of Block Pack (words): 5 0-512 Max. read-command size (words): 256 Not Adjustable Max. write-command size (words): 256 Not Adjustable