Daikin BRC073A4 User Reference Manual
Text of the manual
USER REFERENCE GUIDE
• Thank you for purchasing the wired remote controller.
• This manual describes safety precautions required for the use of the
product.
Read this manual carefully and be sure you understand the
information provided before attempting to use the product.
Keep this manual where it is readily accessible after reading it through.
If another user operates the product in the future, be sure to hand over
this manual to the new user.
BRC073A4
User reference guide
1
Contents
Notices
Safety Precautions ................................................... 2
Items to be Strictly Observed ................................... 3
Names and Functions............................................... 7
Liquid Crystal Display ............................................. 9
Basic Operation Method
Enable/disable the Menu/Enter and Cancel
button...................................................................... 11
Cool/Heat/Fan/Dry/Auto Operation......................... 12
Program Dry Operation .......................................... 16
Setback................................................................... 17
Key Lock ................................................................. 18
Quick Reference of
Main Menu Items
Main Menu Items Overview .................................... 19
Menu Manipulation
Main Menu .............................................................. 21
Airflow Direction...................................................... 22
Energy Saving Options ........................................... 23
Schedule................................................................. 28
Maintenance Information ........................................ 33
Con iguration .......................................................... 34
Current Settings...................................................... 36
Clock & Calendar.................................................... 37
Language................................................................ 39
Maintenance
Maintenance of Unit and the LCD display .............. 40
Reference Information
Error Code Display ................................................. 41
ʺMode Conflictʺ message ....................................... 42
After-sales Service ................................................. 47
User reference guide
2
BRC0731A4
3P4227241-1
The original instructions are written in English. All other languages are translations of the original
instructions.
This appliance is not intended to be used by persons, including children, with reduced physical,
sensory or mental capabilities or lack of experience and knowledge, unless they are supervised or
have been given instructions on how to use the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Please read these Safety Precautions carefully before installing the remote controller.
• This manual classifies the precautions into WARNING and CAUTION.
They both contain important information regarding safety. Be sure to follow all the precautions
below.
WARNING
Failure to follow these instructions properly may result in personal
injury or loss of life.
CAUTION
Failure to observe these instructions properly may result in property
damage or personal injury, which may be serious depending on the
circumstances.
• The following pictograms are used in this manual.
Never do.
Always follow the instructions given.
Be sure to ground the unit.
Absolutely keep wet hands away.
Absolutely keep water and moisture
away.
�About Remote Controller
WARNING
• Do not install the remote controller by yourself.
Improper installation may result in electric shocks or fire.
Consult your Daikin dealer.
• Do not modify or repair the remote controller.
This may result in electric shocks or fire.
Consult your Daikin dealer.
• Do not relocate or reinstall the remote controller by yourself.
Improper installation may result in electric shocks or fire.
Consult your Daikin dealer.
• Do not use flammable materials (e.g., hair spray or insecticide) near the
product.
Do not clean the product with organic solvents such as paint thinner.
The use of organic solvents may cause crack damage to the product, electric shocks or
fire.
Safety Precautions
User reference guide
BRC0731A4
3P422724-1
3
CAUTION
• Do not play with the unit or its remote controller.
Accidental operation by a child may result in impairment of bodily functions and harm
health.
• Never disassemble the remote controller.
Touching the interior parts may result in electric shocks or fire.
Consult your Daikin dealer or authorized contractor for internal inspections and
adjustments.
• To avoid electric shocks, do not operate with wet hands.
• Do not wash the remote controller.
Doing so may cause electric leakage and result in electric shocks or fire.
• Do not leave the remote controller wherever there is a risk of wetting.
If water gets into the remote controller there is a risk of electrical leakage and damage to
electronic components.
�Indoor Unit and Outdoor Unit
WARNING
• Be aware that prolonged, direct exposure to cool or warm air from the air
conditioner or to air that is too cold or too warm can be harmful to your
physical condition and health.
• Do not place objects, including rods, your fingers, etc. in the air inlet or
outlet.
Injury may result due to contact with the air conditioner's high-speed fan blades.
• Contact professional personnel about attachment of accessories and be
sure to use only accessories specified by the manufacturer.
If a defect results from your own workmanship, it may result in water leaks, electric
shock or fire.
• Do not use the product in atmospheres contaminated with oil vapor,
such as cooking oil or machine oil vapor.
Oil vapor may cause crack damage, electric shocks or fire.
• Do not use the product in places with excessive oily smoke, such as
cooking rooms or in places with flammable gas, corrosive gas or metal
dust.
Using the product in such places may cause fire or product failures.
Items to be Strictly Observed
User reference guide
4
BRC0731A4
3P422724-1
Items to be Strictly Observed
WARNING
• Beware of fire in case of refrigerant leakage.
If the air conditioner is not operating correctly, i.e. not generating cool or warm air,
refrigerant leakage could be the cause. Consult your dealer for assistance. The
refrigerant within the air conditioner is safe and normally does not leak. However, in the
event of a leakage, contact with a naked burner, heater or cooker may result in
generation of noxious gas. Do not longer use the air conditioner until a qualified service
person confirms that the leakage has been repaired.
• In the case of using a load breaker provided with a fuse, make sure that
the capacity of the fuse is correct.
Use of an ordinary conductive wire may cause malfunctions or fire.
• Do not use the power supply breaker to start or stop the air conditioner.
Otherwise, fire or water leakage may result.
Furthermore, the fan will rotate abruptly if power failure compensation is enabled, which
may result in injury.
• Be sure to earth the unit.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead.
Imperfect earthing may result in electric shocks or fire. A high surge current from
lightning or other sources may cause damage to the air conditioner.
• When the air conditioner is malfunctioning (giving off a burning odour,
etc). turn off the power and contact your local dealer.
Continued operation under such circumstances may result in a failure, electric shocks or
fire hazards.
• Consult your local dealer regarding what to do in case of refrigerant
leakage.
When the air conditioner is to be installed in a small room, it is necessary to take proper
measures so that the amount of any leaked refrigerant does not exceed the
concentration limit in the event of a leakage.
Otherwise, this may lead to an accident due to oxygen depletion.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks or fire.
• Consult the dealer if the air conditioner submerges owing to a natural
disaster such as a flood or typhoon.
Do not operate the air conditioner in that case or otherwise a malfunction, electric shock
or fire may result.
• Be sure to use a dedicated power supply for the air conditioner.
The use of any other power supply may cause heat generation, fire or product failures.
User reference guide
BRC0731A4
3P422724-1
5
Items to be Strictly Observed
CAUTION
• After prolonged use, check the unit stand and its mounts for damage.
If left in a damaged condition, the unit may fall and cause injury.
• Do not allow a child to mount on the outdoor unit or avoid placing any
object on it.
Falling or tumbling may result in injury.
• Do not block air inlets nor outlets.
Impaired airflow may result in insufficient performance or trouble.
• To avoid injury, do not touch the air inlet or aluminium fins of the unit.
• Do not remove the outdoor unit's fan guard.
The guard protects against the unit's high speed fan, which may cause injury.
• Do not place objects that are susceptible to moisture directly beneath
the indoor or outdoor units.
Under certain conditions, condensation on the main unit or refrigerant pipes, air filter dirt
or drain blockage may cause dripping, resulting in fouling or failure of the object
concerned.
• Do not place water containers (flower vases, etc). on the unit, as this
may result in electric shocks or fire.
• Do not use the air conditioner for purposes other than those for which it
is intended.
Do not use the air conditioner for cooling precision instruments, food, plants, animals or
works of art as this may adversely affect the performance, quality and/or longevity of the
object concerned.
• Do not place appliances that produce naked flames in places exposed to
the airflow from the unit as this may impair combustion of the burner.
• Do not place heaters directly below the unit as resulting heat can cause
deformation.
• Be sure that children, plants or animals are not exposed directly to
airflow from the unit as adverse effects may ensue.
• Do not put flammable containers, such as spray cans, within 1 m from
the blow-off mouth.
The containers may explode because the warm air output of the indoor or outdoor unit
will affect them.
• Do not install the air conditioner at any place where there is a danger of
flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may result in fire
hazards.
User reference guide
6
BRC0731A4
3P422724-1
Items to be Strictly Observed
CAUTION
• Do not sit or stand on any unstable base at the time of operating or
maintaining the air conditioner.
The base may topple down and injury may occur.
• Do not touch the motor when replacing the filter.
The motor can be very hot which may result in burns.
• Do not wash the air conditioner with water as this may result in electric
shocks or fire.
• Perform ventilation from time to time.
Be careful when using the air conditioner with other heating equipment.
Insufficient ventilation may result in oxygen deficiency.
• Always stop the operation of the air conditioner and turn OFF the power
supply breaker when cleaning.
Failure to do so may result in an electric shock or injury.
• Do not wash the interior of the indoor and outdoor units by yourself.
Always consult your Daikin dealer.
The use of an incorrect washing method or incorrect detergent may damage the resin
parts of the indoor unit or cause water leakage.
Moreover, malfunctions, smoke generation or ignition may result if the electric parts or
the motor in the indoor unit come in contact with a detergent or water.
• Do not place objects in direct proximity of the outdoor unit and do not let
leaves and other debris accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such
animals can cause malfunctions, smoke or fire when making contact with electrical
parts.
• Fix the units securely.
If the units are not mounted securely, the units may fall or topple and result in personal
injury.
• Arrange the drain to ensure complete drainage.
If proper drainage from the outdoor drain pipe does not occur during air conditioner
operation, there could be a blockage due to dirt and debris build-up in the pipe.
This may result in water leakage from the indoor unit. Under these circumstances, stop
the air conditioner operation and consult your dealer for assistance.
User reference guide
BRC0731A4
3P422724-1
7
Names and Functions
2. Fan Speed/Airflow
Direction button
3. Menu/Enter button
8. ON/OFF button
10. Cancel button
9. Operation lamp
11. LCD (with backlight)
4. Up button
5. Down button
6. Right button
7. Left button
1. Operation Mode
Selector button
Functions other than the basic operation items (i.e., ON/OFF,
operation mode selection, fan speed, up/down direction, and
temperature setting) are set from the menu screen.
NOTE
• Do not install the remote controller in places exposed to direct sunlight.
Otherwise, the LCD may become discolored and nothing may be displayed.
• Do not pull or twist the remote controller cord.
Otherwise, the remote controller may malfunction.
• Do not press the buttons on the remote controller with objects with sharp ends.
Otherwise, the remote controller may be damaged or malfunction.
User reference guide
8
BRC0731A4
3P422724-1
Names and Functions
1. Operation Mode Selector button
• Press this button to select the operation
mode of your preference. (See "Cool/
Heat/Fan/Dry/Auto Operation" on page 12)
• Available modes may vary with the
connected model.
2. Fan Speed/Airflow Direction
button
• Used to change the fan speed and airflow
direction. (See "Cool/Heat/Fan/Dry/Auto
Operation" on page 13)
• Available fan speeds and airflow directions
may vary with the connected model.
3. Menu/Enter button
• This button is enabled by default.
To disable, refer to "Enable/disable the
Menu/Enter and Cancel button" on
page 11.
• Used to display the Main Menu or enter the
selected item (See "Main Menu Items
Overview" on page 19).
4. Up button
• Used to raise the set temperature.
• The next item on the upper side will be
highlighted.
(Keep pressing the button to cycle through
the values or items).
• Used to change the selected item.
5. Down button
• Used to lower the set temperature.
• The next item on the lower side will be
highlighted.
(Keep pressing the button to cycle through
the values or items).
• Used to change the selected item.
6. Right button
• Used to highlight the next items on the
right-hand side.
• The display contents are changed to the
next screen.
7. Left button
• Used to highlight the next items on the
left-hand side.
• The display contents are changed to the
previous screen.
8. ON/OFF button
• Press to start or stop the air conditioner.
9. Operation lamp (Green)
• This lamp lights up during operation.
• This lamp is not lit when the unit operation
is OFF.
• This lamp blinks if an error or mode conflict
occurs.
10. Cancel button
• This button is enabled by default.
To disable, refer to "Enable/disable the
Menu/Enter and Cancel button" on
page 11.
• Used to return to the previous screen.
11. LCD (with backlight)
• The backlight will be lit for approximately
30 seconds when one of the buttons is
pressed.
• The actions linked to the buttons , except
for the ON/OFF button, are not carried out
when the backlight is not lit.
User reference guide
BRC0731A4
3P422724-1
9
Names and Functions
Liquid Crystal Display
• There are four display methods for the liquid crystal display (LCD) available. The
Standard display, which is used by default, and the Detailed display. There is also the
possibility to use only Icon or Icon and Text mode (see the Installer reference guide).
• To change the active display method, select the desired display method in the Display
Method screen (See "Display" on page 34).
• The displayed contents on the screen may vary with the operation mode of the
connected models. (E.g.: The following display will appear when the air conditioner is
in heating operation).
Standard display
With icons (default)
With icons and text
28°C
5
7
4
6
8
3
2
1
28°C
Heat
Error: Push Menu button
5
7
4
6
8
3
2
1
Set to
Detailed display
� The clock and Detailed selection items appear on the Detailed
display in addition to the items appearing on the Standard display.
With icons
With icons and text
10
9
Fri 11:03
4
10
9
Fri 11:03
3
4
11
Error: Push Menu button
Heat
2
Set to
Room
User reference guide
10
BRC0731A4
3P422724-1
Names and Functions
1. Operation mode
• Indicates the current operation mode.
Operation Mode
Cool
Heat
Auto (Heat)
Fan
Dry
Auto (Cool)
2. Fan speed
(See "Cool/Heat/Fan/Dry/Auto Operation"
on page 12)
• Indicates the fan speed that is set for the
air conditioner.
• The fan speed will not be displayed if the
air conditioner does not have the fan speed
control function.
3. Airflow direction
• Displayed only when the air conditioner is
in operation.
• Indicates the airflow direction that is set for
the air conditioner.
• The possible directions depend on the
indoor unit.
4. Set/Setback temperature display
(See "Setback" on page 17)
• When the unit is turned ON, the
temperature that is set for the air
conditioner is displayed.
• When the unit is turned OFF and Setback
is disabled, the temperature that is set for
the air conditioner is displayed.
• When the unit is turned OFF and Setback
is enabled, the temperature that is set for
the setback function is displayed in smaller
digits.
5. Error " "
(See "Error Code Display" on page 41
• Indicates a unit error.
6. Timer enabled "
(SkyAir and VR
" V)
(See "OFF Timer" on page 27 and
"Schedule" on page 28)
• Indicates that the schedule timer or the
OFF timer is enabled.
7. Under Centralised control "
"
• Indicates that the air conditioner is under
the management of central control
equipment (optional accessories) and the
operation of the system through the remote
controller is prohibited.
8. Setback " "
(See "Setback" on page 17)
• The setback icon flashes when the unit is
turned on under the setback control.
9. Clock (12/24 hours real time clock)
(See "Clock & Calendar" on page 38)
• Indicates that the clock is set.
• If the clock is not set, " -- : -- " will be
displayed.
10. Detailed selection
(See "Display Mode" on page 34)
• Is displayed when the detailed display
mode is selected.
• No detailed items are selected by default.
11. Timer problem "
"
• Indicates that the clock needs to be set
again.
• The schedule timer function will not work
unless the clock is set again.
User reference guide
BRC0731A4
3P422724-1
11
1
1/2
Airflow Direction
Energy Saving Options
Schedule
Maintenance Information
Configuration
Current Settings
Setting
Return
Main Menu
• Display the Main Menu. (See
"Manipulating the Main Menu" on page 21).
• Press the
(Up/Down) buttons to
select Schedule and press the Menu/Enter
button.
2
No
Yes
Schedule
Clock has not been set
Would you like to set it now?
Setting
Return
0:00
Wednesday
1
Day
1
Month
2014
Year
Setting
Date & Time
Return
• Press the
(Left/Right) buttons to
select Yes and press the Menu/Enter
button.
• The Date & Time screen will appear.
• Set the current year, month, day, and time.
(See "Clock & Calendar" on page 37).
Note
• Before setting the schedule, the clock must
be set.
• If the clock has not been set, a screen like
the one on the left will appear.
Operation Method
Remote Controller
Functions
Operation procedure
Operate the buttons according to
the procedure.
Button display
Displays the positions
of the buttons to be
operated.
Screen display
Screens that will be
displayed on the
remote controller.
Enable/disable the Menu/Enter and Cancel button
Operation Method By default, the Menu/Enter and Cancel button are enabled.
1
2
2
2
2
1
• To enable/disable the Menu/Enter and
Cancel button, keep the
(Right) button
pressed in the Basic Screen.
2
2
2
2
2
1
• Press the 3 keys simultaneously while
keeping the
(Right) button pressed.
Basic Operation Method
User reference guide
12
BRC0731A4
3P422724-1
Basic Operation Method
Cool/Heat/Fan/Dry/Auto Operation
1
28°C
• Press the Operation Mode Selector button
several times until the desired mode (Cooling,
Heating, Fan Only, Dry or Auto) is selected.
Note
• Unavailable operation modes are not displayed.
• Only Cooling, Dry or Fan Only mode can be selected if the air
conditioner is a cooling-only model.
2
• Press the ON/OFF button.
The Operation lamp (green) will be lit and the
air conditioner will start operating.
3
28°C
• The set temperature will increase by
1°C when the
(Up) button is pressed
and decrease by 1°C when the
(Down) button is pressed.
Note
Temperature settings are not possible while in Dry or Fan Only
mode.
4
28°C
• To change the fan speed or airflow direction,
press the Fan Speed/Airflow Direction button.
Return
Setting
Return
Setting
Swing stop
Lv. 1 (L)
Airfow level /direction
level
Direction1
• To select air volume or airflow direction
setting, press the
buttons.
• Press the
(Up/Down) buttons to select
the desired level or position.
Operation Method
User reference guide
BRC0731A4
3P422724-1
13
Basic Operation Method
High
Medium-high
Auto
Medium
Medium-low
Low
Note
• The air conditioner may be in automatic fan speed control for
mechanical protection purposes.
• The air conditioner may be in automatic fan speed control
according to the room temperature.
• The fan may stop operating, which is not a failure.
• It may take time until fan speed changes are actually carried
out.
• In Auto fan speed, the fan speed is adjusted automatically
according to the setpoint and indoor temperature.
Return
Setting
Return
Setting
Lv. 1 (L)
Swing stop
Airfow level /direction
level
Direction1
• With airflow direction selected, select the desired airflow
direction from Swing or Swing stop using the
(Up/Down)
buttons.
Return
Setting
Return
Setting
Lv. 1 (L)
Swing
Airfow level /direction
level
Direction1
Airflow direction
setting (up/down)
Note
• The airflow directions appear on the screen as follows:
Up/down direction
Left/right direction
• Selecting Swing will cause the airflow direction blades to swing
back and forth.
• When you select Swing stop , the airflow direction blades stay
in the position of when you press the Menu/Enter button.
Note
• To change the left/right airflow direction, refer to "Change the
Airflow direction" on page 22.
User reference guide
14
BRC0731A4
3P422724-1
Basic Operation Method
5
• When the ON/OFF button is pressed again,
the air conditioner will stop operating and the
Operation lamp will turn OFF.
Note
• When the system is stopped while in heating operation, the fan
will continue to operate for approximately 1 minute in order to
eliminate the residual heat in the indoor unit.
User reference guide
BRC0731A4
3P422724-1
15
Basic Operation Method
Characteristics of Cooling Operation
• When the outdoor air temperature is high, it takes some time until the
room temperature reaches the set temperature.
Characteristics of Heating Operation
Starting operation
• Heating operation generally requires a longer time to attain the set
temperature compared with cooling operation.
It is recommended to start operating the air conditioner in advance by
using the timer.
Perform the following operation in order to prevent the degradation of the
heating capability or cold drafts.
Defrost operation
• The air conditioner will automatically go into defrost operation to
prevent frost accumulation at the outdoor unit which results in loss of
the heating capacity.
• The air conditioner will return to normal operation after approximately
6 to 8 minutes (Max 10 minutes).
• During defrost mode the temperature near the indoor room temp is
displayed. This may be affected by the location of the unit.
Outdoor
temperature and
heating capability
• The heating capacity of the air conditioner will drop when the outdoor
temperature decreases.
If the heating effect is insufficient, it is recommended to use another
heating appliance in combination with the air conditioner. (When a
combustion appliance is used, ventilate the room regularly).
Do not use the heating appliance in places where the heating
appliance is exposed to the airflow of the air conditioner.
• The air conditioner is a hot air circulation type. Therefore, it takes
some time to warm up the room after the air conditioner starts
operating.
The indoor fan will automatically operate until the indoor temperature
of the system rises to a certain level.
• If hot air stays around the ceiling and your feet feel cold, a circulator is
recommended.
For details, consult your Daikin dealer.
User reference guide
16
BRC0731A1
3P422724-1
Basic Operation Method
Program Dry Operation
Preparation
• The dry mode may not be selected if the remote controller has no eligibility to select cooling/
heating mode.
1
• Press the Operation Mode Selector button several
times until Dry mode is selected.
Note
Dry mode may not be available depending on the type of indoor
unit.
2
• Press the ON/OFF button.
The Operation lamp will be lit and the air
conditioner will start operating.
Note
The air conditioner is in automatic temperature and fan speed
control. Therefore, the temperature or fan speed cannot be
changed while the air conditioner is in operation.
3
• To set the airflow direction, see "Airflow Direction" on page 22.
4
• When the ON/OFF button is pressed again, the air
conditioner will stop operating and the Operation
lamp will turn OFF.
Note
To prevent water leakage or system failure, do not turn OFF the
power soon after the air conditioner stops operating. Be sure to
wait at least 5 minutes so that the drain pump finishes discharging
the residual water from the indoor unit.
Operation Method
User reference guide
BRC0731A4
3P422724-1
17
Basic Operation Method
Characteristics of Dry Operation
In Dry operation, the air humidity will be lowered by intermittently
turning the air conditioner ON in cooling and OFF again to minimize
the temperature decrease.
Note
• The temperature and fan speed are controlled automatically and
cannot be controlled by the remote controller.
• Dry operation will not function if the room temperature is too low.
Setback
The Setback function will maintain the room temperature in a specific range when the remote
controller is turned OFF. This is done by temporarily starting the air conditioner that was previously
turned OFF by the user, the schedule function or the OFF timer.
OFF
Heating
Operation
Cooling Operation
10°C 12°C
33°C 35°C
For example:
[ Setback setpoint temperature: cool 35°C, heat 10°C ]
[ Recovery differential: cool -2°C, heat +2°C ]
• If the room temperature drops below 10°C, heating is started automatically. If after half an hour
the temperature increases to 12°C or above, the controller returns to its original state.
• If the room temperature goes above 35°C, cooling is started automatically. If after half an hour
the temperature drops to 33°C or below, the controller returns to its original state.
Note
• This function is disabled by default. This function can only be enabled/disabled in the Energy
Saving List (See "Energy Saving Options" on page 23).
• The differential can be adjusted in the Setback Condition menu (See "Setback Condition" on
page 25).
• The setback temperature can be set while the unit is turned off on the Basic Screen or set in the
schedule.
• Setback will turn the unit ON for at least 30 minutes unless the setback temperature setpoint is
changed or the unit is turned ON with the ON/OFF button.
• When setback turns the air conditioner ON while in Auto mode, the remote controller switches to
Cooling or Heating only, depending on what is appropriate, and only the respective setback
temperature setpoint is shown.
• The temperature is measured inside the air conditioner unit (when the unit is switched OFF). As
there is no actual air flow, the measured temperature inside the air conditioner unit can deviate
(up to 3°C) from the actual room temperature.
User reference guide
18
BRC0731A4
3P422724-1
Basic Operation Method
Operation Method
Setback should not be enabled when a centralised controller is connected
via the KRP928 Interface adapter for Room Air Conditioner.
1
35°C
The setback icon "
" flashes when the unit is turned ON under
the setback control.
The fan speed cannot be changed when setback is active and,
as a result, the fan speed is not visible.
The airflow direction can only be changed through the menu when
setback is active.
Key Lock
Operation Method
Disable the use of all buttons.
1
28°C
• Press the Menu/Enter button for at least
4 seconds. (During backlight lit)
2
Buttons have been locked.
Press the menu button
for 4 seconds to release.
Return
• All buttons are disabled when the keys are locked.
• When one of the buttons is pressed, the message
on the left is displayed.
3
• To cancel the key lock, continue pressing the
Menu/Enter button for at least 4 seconds. (During
backlight lit)
User reference guide
BRC0731A4
3P422724-1
19
Quick Reference of Main Menu Items
�Main Menu Items Overview1
Note
• The available items may vary with the connected model.
• Only the available items will appear in the menu.
Setting and display items
Description
Reference
page
Airflow Direction
Change the airflow direction.
• The airflow direction blades can be
automatically operated up and down and
left and right.
• There are swing or swing stop directions.
• This function is not available on all models.
22
Energy
Saving
Options(1)
Energy Saving List
Enable or disable the "Energy Saving
Options".
23
Setpoint Range
The setpoint temperature range can be
restricted for the Cooling, Heating and Auto
Mode.
24
Setback Condition
Set the setback differential temperature after
which the unit will turn back OFF.
25
Setpoint Auto Reset
Change the temperature setpoint to a preset
temperature setpoint after running for a set
period of time, even if the temperature
setpoint has been changed.
• Possible to set from 30 to 120 minutes in 30
minute increments.
26
Off Timer
The system is turned off automatically after
the selected time each time the system is
activated.
• Possible to set in 10 minute increments
from 30 to 180 minutes.
27
Schedule(2)
Enable/Disable
Enable or disable schedule function.
28
Schedule Number
Settings
Select the active schedule number (schedule
nr 1, 2 or 3).
29
Holidays
Select the days of the week for which the
schedule will be disabled. This function is
used for when the schedule doesn't need to
be active, e.g. like when you are on holiday.
30
Settings
Select when the operation modes start and/or
stop for each day of the week. Up to
5 actions can be set for each day.
31
1) Setback, Setpoint Range, Setback Condition and Setpoint Auto Reset should not be used when a centralised controller is connected
via the KRP928 Interface adapter for Room Air Conditioner.
2) The schedule can be restricted when a centralised controller is connected via the KRP928 Interface adapter for Room Air
Conditioner.
User reference guide
20
BRC0731A4
3P422724-1
Quick Reference of Main Menu Items
Setting and display items
Description
Reference
page
Maintenance Information
Display the service contact.
33
Configuration Display
• Display:
Switch between Standard or Detailed
display.
• Detailed display settings:
Select if room temperature (near the indoor
unit), outdoor temperature, or nothing is
displayed.
34
Contrast Adjustment Adjust the LCD contrast.
36
Current Settings
Display a list of the current settings of the
available items.
36
Clock &
Calendar
Date & Time
Configure the date and time settings.
• The default time display is 24H.
• The clock will maintain accurate within
±30 seconds per month.
• If there is a power failure for a period not
exceeding 48 hours, the clock will continue
working with the built-in backup power
supply.
37
12H/24H Clock
The time can be displayed in either a 12 hour
or 24 hour time format.
38
Language
Choose the language depending on the
language pack installed.
39
User reference guide
BRC0731A4
3P422724-1
21
Main Menu
�Manipulating the Main Menu
1
28°C
Basic Screen
•
Press the Menu/Enter button.
2
Setting
Return
Airflow Direction
Energy Saving Options
Schedule
Maintenance Information
Configuration
Current Settings
1/2
Main Menu
Main Menu
• The Main Menu will appear.
Instructions for manipulating the buttons will
appear.
3
• Selecting items from the Main Menu.
1. Press the
(Up/Down) buttons to select
the desired item.
2. Press the Menu/Enter button to display the
selected settings screen.
4
• To go back to the Basic Screen from the Main
Menu, press the Cancel button.
Caution
• When the Main Menu is visible and a button is not pressed for 5 minutes, the screen will
automatically go back to the Basic Screen.
Operation Method
Menu Manipulation
User reference guide
22
BRC0731A4
3P422724-1
Menu Manipulation
Airflow Direction
�Change the Airflow direction
Operation Method
1
Setting
Return
Airflow Direction
Energy Saving Options
Schedule
Maintenance Information
Configuration
Current Settings
1/2
Main Menu
• Display the Main Menu (See "Manipulating the
Main Menu" on page 21)
• Press the
(Up/Down) buttons to select
Airflow Direction and press the Menu/Enter
button.
2
Airflow Direction
Direction1
Swing
Setting
Return
Direction2
Swing
Swing
Setting
Return
Direction
Airflow Direction
Direction2
Swing
Airflow direction
setting (up/down)
Swing
Direction
Airflow Direction
Setting
Return
Direction2
Swing
Airflow direction
setting (left/right)
Remark: Only visible if
available.
• Select the desired airflow direction from Swing
or Swing stop using the
(Up/Down) buttons.
• Select Up/down direction or Left/right direction
using the
(Left/Right) buttons.
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Note
• The airflow directions appear on the screen as follows:
Up/down direction
Left/right direction
• Selecting Swing will cause the airflow direction blades to
swing back and forth. When Swing is selected, all airflow
directions will be visible at the same time.
• When you select Swing stop , the airflow direction blades stay
in the position that you press the Menu/Enter button.
User reference guide
BRC0731A4
3P422724-1
23
Menu Manipulation
Movement of the airflow direction blades
When the following operation conditions are active, the airflow direction is controlled
automatically. Actual operation may thus be different than what is displayed on the remote
controller.
Operation
condition
• Room temperature is higher than the remote controller's set
temperature (in heating mode).
• Under continuous operation with the airflow blowing horizontally.
Note
Heating mode includes automatic operation.
Energy Saving Options
�Energy Saving List
Some functions should not be enabled when a centralised controller is
Operation Method connected via the KRP928 Interface adapter for Room Air Conditioner.
1
Airflow Direction
Energy Saving Options
Schedule
Maintenance Information
Configuration
Current Settings
1/2
Setting
Return
Main Menu
• Display the Main Menu.
(See "Manipulating the Main Menu" on
page 21).
• Press the
(Up/Down) buttons to select
Energy Saving Options and press the Menu/
Enter button.
2
Energy Saving List
Setpoint Range
Setback Condition
Setpoint Auto Reset
Off Timer
1/2
Energy Saving Options
Setting
Return
• Press the
(Up/Down) buttons to select
Energy Saving List and press the Menu/Enter
button.
3
Setpoint Range
Setback Condition
Setpoint Auto Reset
Off Timer
Energy Saving List
Setting
Return
: ON
: OFF
: OFF
: OFF
• Press the
(Up/Down) buttons to change the
setting to ON or OFF .
• Move the cursor using the
(Left/Right)
buttons.
• Press the Menu/Enter button when all changes
are made. The confirmation screen will appear.
User reference guide
24
BRC0731A4
3P422724-1
Menu Manipulation
4
No
Yes
Energy Saving List
Save the settings?
Setting
Return
• Press the
(Left/Right) buttons to select Yes .
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
�Setpoint Range Setting
1
Energy Saving List
Setpoint Range
Setback Condition
Setpoint Auto Reset
Off Timer
Energy Saving Options
Setting
Return
• Display the Energy Saving Options (See "Energy
Saving List" on page 23).
• Press the
(Up/Down) buttons to select
Setpoint Range and press the Menu/Enter
button.
2
18°C
– 32°C
10°C – 30°C
18°C – 30°C
Setpoint Range
Setting
Return
Cool
Heat
Auto
• Press the
(Up/Down) buttons to change the
cooling or heating temperature setpoint range.
• Move the cursor using the
(Left/Right)
buttons.
• Press the Menu/Enter button when all changes are
made. The confirmation screen will appear.
Note
• The default setpoint range restriction is [18°C→32°C] for cooling, [10°C→30°C] for heating,
and [18°C→30°C] for auto. This setpoint range is the general setpoint range and is as a result
always active regardless of whether Setpoint Range is enabled or disabled.
• The default setpoint range for setback operation is [33°C→37°C] for cooling and [10°C→15°C]
for heating. This setpoint range cannot be changed.
3
No
Yes
Setpoint Range
Save the settings?
Setting
Return
• Press the
(Left/Right) buttons to select Yes .
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Operation Method
This function should not be used when a centralised controller is connected
via the KRP928 Interface adapter for Room Air Conditioner.
User reference guide
BRC0731A4
3P422724-1
25
Menu Manipulation
�Setback Condition
1
Energy Saving List
Setpoint Range
Setback Condition
Setpoint Auto Reset
Off Timer
Energy Saving Options
Setting
Return
• Display the Energy Saving Options (See "Energy
Saving List" on page 23).
• Press the
(Up/Down) buttons to select
Setback Condition and press the Menu/Enter
button.
2
-2°C
Recovery Differential
Cool
Heat
+2°C
Setback Condition
Setting
Return
• Press the
(Up/Down) buttons to change the
differential for setback operation.
• Move the cursor using the
(Left/Right)
buttons.
• Press the Menu/Enter button when all changes are
made. The confirmation screen will appear.
3
No
Yes
Setback Condition
Save the settings?
Setting
Return
• Press the
(Left/Right) buttons to select Yes .
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Note
• The default setpoint range restriction is [18°C→32°C] for cooling, [10°C→30°C] for heating,
and [18°C→30°C] for auto. This setpoint range is the general setpoint range and is as a result
always active regardless of whether Setpoint Range is enabled or disabled.
• The default setpoint range for setback operation is [33°C→37°C] for cooling and [10°C→15°C]
for heating. This setpoint range cannot be changed.
Operation Method
This function should not be used when a centralised controller is connected
via the KRP928 Interface adapter for Room Air Conditioner.
User reference guide
26
BRC0731A4
3P422724-1
Menu Manipulation
�Setpoint Auto Reset
1
Energy Saving List
Setpoint Range
Setback Condition
Setpoint Auto Reset
Off Timer
Energy Saving Options
Setting
Return
• Display the Energy Saving Options (See "Energy
Saving List" on page 23).
• Press the
(Up/Down) buttons to select
Setpoint Auto Reset and press the Menu/Enter
button.
2
28 °C
30 min
20°C
30 min
Cool
Heat
2/2
Set temp.:
Set Time:
Set temp.:
Set Time:
Setpoint Auto Reset
Setting
Return
• Press the
(Up/Down) buttons to set the
preset temperature and timing for the auto reset of
the setpoint.
• Move the cursor using the
(Left/Right)
buttons.
• Press the Menu/Enter button when all the changes
are made. The confirmation screen will appear.
3
No
Yes
Setpoint Auto Reset
Save the settings?
Setting
Return
• Press the
(Left/Right) buttons to select Yes .
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Operation Method
This function should not be used when a centralised controller is connected
via the KRP928 Interface adapter for Room Air Conditioner.
User reference guide
BRC0731A4
3P422724-1
27
Menu Manipulation
�OFF Timer
1
Energy Saving List
Setpoint Range
Setback Condition
Setpoint Auto Reset
Off Timer
Setting
Return
Energy Saving Options
• Display the Energy Saving Options (See "Energy
Saving List" on page 23).
• Press the
(Up/Down) buttons to select
Off Timer and press the Menu/Enter button.
2
Setting
Return
Off Timer
60
After you turn on the unit,
it will automatically
turn off in
minutes.
• Use the
(Up/Down) buttons to set the time
after which the unit automatically turns off again.
Selections can be made in increments of
10 minutes from 30 to 180 minutes.
Holding down the button causes the number to
change continuously.
The settings confirmation screen will appear when
the Menu/Enter button is pressed.
3
No
Yes
Off Timer
Save the settings?
Setting
Return
• Press the
(Left/Right) button to select Yes .
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Operation Method
User reference guide
28
BRC0731A4
3P422724-1
Menu Manipulation
Schedule
�Enable/Disable
Operation Method
The schedule can be restricted when a centralised controller is connected
via the KRP928 Interface adapter for Room Air Conditioner.
1
1/2
Airflow Direction
Energy Saving Options
Schedule
Maintenance Information
Configuration
Current Settings
Setting
Return
Main Menu
• Display the Main Menu.
(See "Manipulating the Main Menu" on page 21).
• Press the
(Up/Down) buttons to select
Schedule and press the Menu/Enter button.
2
No
Yes
Schedule
Clock has not been set
Would you like to set it now?
Setting
Return
0:00
Wednesday
1
Day
1
Month
2014
Year
Setting
Date & Time
Return
Note
• Before setting the schedule, the clock must be
set.
• If the clock has not been set, a screen like the
one on the left will appear.
• Press the
(Left/Right) buttons to select Yes
and press the Menu/Enter button.
• The Date & Time screen will appear.
• Set the current year, month, day and time. (See
"Clock & Calendar" on page 38).
3
2/2
Enable/Disable
Select Schedule
Holidays
Settings
Schedule
Setting
Return
• Press the
(Up/Down) buttons to select
Enable/Disable and press the Menu/Enter button.
4
Disable
Schedule
Enable/Disable
Setting
Return
• Press the
(Up/Down) buttons to select
Enable or Disable .
• The confirmation screen will appear when the
Menu/Enter button is pressed.
Note
The Schedule is enabled. To modify the Selected
schedule number see "Select Schedule" on
page 30.
User reference guide
BRC0731A4
3P422724-1
29
Menu Manipulation
5
No
Yes
Schedule
Save the settings?
Setting
Return
• Press the
(Left/Right) buttons to select Yes .
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
�Select Schedule
1
2/2
Enable/Disable
Select Schedule
Holidays
Settings
Schedule
Setting
Return
• Display the Schedule menu. (See
"Enable/Disable" on page 28).
• Press the
(Up/Down) buttons to select
Select Schedule and press the Menu/Enter
button.
2
Schedule nr 1
Schedule
Select Schedule
Setting
Return
• Press the
(Up/Down) buttons to select
Schedule nr 1 , Schedule nr 2 or Schedule nr 3 .
• The confirmation screen will appear when the
Menu/Enter button is pressed.
3
No
Yes
Schedule
Save the settings?
Setting
Return
• Press the
(Left/Right) buttons to select Yes .
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Operation Method
It is possible to program up to three different schedules.
User reference guide
30
BRC0731A4
3P422724-1
Menu Manipulation
�Holidays
1
Enable/Disable
Select Schedule
Holidays
Settings
Schedule
Setting
Return
• Display the Schedule menu. (See "Enable/
Disable" on page 28).
• Press the
(Up/Down) buttons to select
Holidays and press the Menu/Enter button.
2
Sat
Mon Tue Wed Thu Fri
Sun
Holidays
Multiple selection
Schedule
Setting
Return
• Press the
(Left/Right) buttons to select the
desired day.
• Press the
(Up/Down) buttons to display "
"
to set this day as a holiday.
Note
• Multiple days can be selected as holidays.
• To re-enable the schedule timer for the day selected as a holiday, the holiday setting must be
released.
3
Sat
Mon Tue Wed Thu Fri
Sun
Holidays
Multiple selection
Schedule
Setting
Return
• Press the Menu/Enter button when all changes are
made. The settings confirmation screen will
appear.
4
No
Yes
Schedule
Save the settings?
Setting
Return
• Press the
(Left/Right) button to select Yes .
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Schedule nr 1
Sun
Hol
Setting
Return
Time Act Cool Heat
Note
"Hol" will be displayed on the schedule settings
screen for days that have been set as a holiday.
Operation Method
The schedule timer will be disabled for days that have been set as a holiday.
User reference guide
BRC0731A4
3P422724-1
31
Menu Manipulation
�Schedule Settings
1
2/2
Enable/Disable
Select Schedule
Holidays
Settings
Schedule
Setting
Return
• Display the Schedule menu. (See
"Enable/Disable" on page 28).
• Press the
(Up/Down) buttons to select
Settings and press the Menu/Enter button.
Note
The Schedule Settings of the selected schedule can be modified. To modify the selected
schedule see "Select Schedule" on page 29.
2
Mon
Schedule nr 1
Setting
Return
Time Act Cool Heat
• Press the
(Up/Down) buttons to select the
day to be set.
3
Setting
Return
Time Act Cool Heat
– 6 :00
Schedule nr 1
Mon
Setting
Return
Time Act Cool Heat
– 6 :00
Mon
Schedule nr 1
• Set the time for the selected day.
• Press the
(Left/Right) buttons to move the
highlighted item and press the
(Up/Down)
buttons to input the desired operation start time.
Each press of the
(Up/Down) buttons moves
the numbers by 1 hour or 1 minute.
Operation Method
After saving a schedule, the schedule is automatically enabled.
User reference guide
32
BRC0731A4
3P422724-1
Menu Manipulation
4
Setting
Return
Time Act Cool Heat
– 6 :00
Schedule nr 1
Mon
Time Act Cool Heat
– 6 :00 ON 32°C 16°C
Schedule nr 1
Setting
Return
Mon
• Press the
(Left/Right) buttons to move the
highlighted item and press the
(Up/Down)
buttons to configure ON/OFF/-- settings.
"Act"-column:
ON : The temperature setpoints can be
configured.
OFF : The setback temperature setpoints can be
configured.
– – : The temperature and setback temperature
setpoints will be disabled.
• Press the
(Left/Right) buttons to move the
highlighted item and press the
(Up/Down)
buttons to input the cooling and heating
temperature setpoints for ON or OFF (Setback)
operation.
"Cool" and "Heat" column:
"__": Indicates that the temperature and setback
temperature setpoint for this time period is
not specified. The last active setpoint will be
utilized.
"– –": Indicates that the setback function is
disabled for this time period.
Time Act Cool Heat
– 6 :00 ON 24°C 21°C
– 8 :00 OFF
Mon
Schedule nr 1
Setting
Return
5
Time Act Cool Heat
– 6 :00 ON
24°C 21°C
– 8 :00 OFF
29°C 10°C
1 7 :30 ON
24°C 21°C
2 2 :00
Schedule nr 1
Setting
Return
Mon
Time Act Cool Heat
– 6 :00 ON
24°C 21°C
– 8 :00 OFF
29°C 10°C
1 7 :30 ON
24°C 21°C
2 2 :00 OFF
28°C 17°C
Mon
Schedule nr 1
Setting
Return
Time Act Cool Heat
– 6 :00 ON
24°C 21°C
– 8 :00 OFF
29°C 10°C
1 7 :30 ON
24°C 21°C
2 2 :00 OFF
28°C 17°C
Tue
Schedule nr 1
Setting
Return
Note
A maximum of 5 actions per day can be set.
• Press the Menu/Enter button when all changes are
made. The confirmation screen will appear.
Note
To copy the settings from the previous day, press
the Operation Mode Selector button.
Example: To copy the contents of Monday to
Tuesday, select Tuesday and press the Operation
Mode Selector button.
User reference guide
BRC0731A4
3P422724-1
33
Menu Manipulation
6
Setting
Return
No
Yes
Schedule
Save the settings?
• Press the
(Left/Right) buttons to select Yes .
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Maintenance Information
�Display the Maintenance Information
1
Setting
Return
Airflow Direction
Energy Saving Optiopns
Schedule
Maintenance Information
Configuration
Current Settings
1/2
Main Menu
• Display the Main Menu. (See "Manipulating the
Main Menu" on page 21).
• Press the
(Up/Down) buttons to select
Maintenance Information and press the Menu/
Enter button.
2
Contact Info
0123–4567–8900
Indoor Model
––––––––––
Outdoor Model
––––––––––
Maintenance Information
Return
• The phone number for the contact address will
appear at the top of the screen.
(If you have not yet registered your product, it will
not appear).
• The model information of the indoor and outdoor
units of your product will always show ----------.
• Press the Cancel button to return to the previous
screen.
Note
• The error code may also appear.
If the operation lamp is not blinking, the unit is
working properly.
• The error code record will disappear if you press
the ON/OFF button for more than 4 seconds.
Operation Method
User reference guide
34
BRC0731A4
3P422724-1
Menu Manipulation
Configuration
�Display
Display Mode
1
Display
Contrast Adjustment
Configuration
Setting
Return
• Display the Configuration menu.
• Press the
(Up/Down) buttons to select
Display and press the Menu/Enter button.
2
Display Mode
Standard
Display Item
None
Display
Setting
Return
• Press the
(Up/Down) buttons to select
Display Mode and press the Menu/Enter button.
3
Standard
Display
Display Mode
Setting
Return
• Press the
(Up/Down) buttons to select
Standard or Detailed .
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Note
To select which item is displayed in the detailed display selection area, refer to "Detailed Item"
on page 35.
Operation Method
User reference guide
BRC0731A4
3P422724-1
35
Menu Manipulation
Detailed Item
1
Display Mode
Standard
Display Item
None
Display
Setting
Return
• Display the Display menu. (See "Display Mode" on
page 34).
• Press the
(Up/Down) buttons to select
Display Item and press the Menu/Enter button.
2
None
Display
Display Item
Setting
Return
• Press the
(Up/Down) buttons to display the
following.
*
Room Temp
Outside Air Temp
None
* Some models may not display these items even if they are
selected.
• Be sure to read the following regarding the display of the room
and outdoor temperature.
Room Temp
– The temperature near the indoor unit.
– The temperature that is detected may be affected by the
location of the unit.
Outside Air Temp
– The temperature detected near the outdoor unit.
– The temperature that is detected may be affected by factors
such as the location of the unit (e.g. if it is in direct sunlight)
and unit operation during defrosting.
– "Outside Air Temp" will not display after stopping or
immediately after starting.
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Operation Method
User reference guide
36
BRC0731A4
3P422724-1
Menu Manipulation
�Contrast Adjustment
1
Display
Contrast Adjustment
Configuration
Setting
Return
• Display the Configuration menu.
• Press the
(Up/Down) buttons to select
Contrast adjustment and press the Menu/Enter
button.
2
Contrast Adjustment
Light
Dark
Setting
Return
• Press the
(Up/Down) buttons until you reach
the desired contrast.
• Press the Menu/Enter button to confirm the setting
and to return to the Basic Screen.
Current Settings
�Overview of the Current Settings
1
1/2
Airflow Direction
Energy Saving Options
Schedule
Maintenance Information
Configuration
Current Settings
Main Menu
Setting
Return
• Display the Main Menu. (See "Manipulating the
Main Menu" on page 21).
• Press the
(Up/Down) buttons to select
Current Settings and press the Menu/Enter
button.
2
Schedule
Display Mode
Display Item
Disable
Standard
None
Current Settings
Return
• A list showing the status of the current settings will
appear.
• Press the Cancel button to return to the Main
Menu.
Schedule
Display Mode
Display Item
Display items
* Display items may differ depending on the model. Only the items that can be set are displayed.
Operation Method
Operation Method
User reference guide
BRC0731A4
3P422724-1
37
Menu Manipulation
Clock & Calendar
�Date & Time
1
Setting
Return
Clock & Calendar
Language
2/2
Main Menu
• Display the Main Menu. (See "Manipulating the
Main Menu" on page 21).
• Press the
(Up/Down) buttons to select
Clock & Calendar and press the Menu/Enter
button.
2
Date & Time
12H/24H Clock
Clock & Calendar
Setting
Return
• Press the
(Up/Down) buttons to select
Date & Time and press the Menu/Enter button.
3
0:00
Wednesday
1
Day
1
Month
2014
Year
Setting
Date & Time
Return
• Use the
(Up/Down) buttons to change the
date and time.
• Move the cursor using the
(Left/Right)
buttons.
• Press the Menu/Enter button when all changes are
made. The confirmation screen will appear.
Note
The day of the week is set automatically.
4
No
Yes
Date & Time
Save the settings?
Setting
Return
• Press the
(Left/Right) button to select Yes .
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Operation Method
User reference guide
38
BRC0731A4
3P422724-1
Menu Manipulation
�12H/24H CLOCK
1
Date & Time
12H/24H Clock
Clock & Calendar
Setting
Return
• Display the Clock & Calendar menu. (See "Date &
Time" on page 37).
• Press the
(Up/Down) buttons to select
12H/24H Clock and press the Menu/Enter button.
2
24H
12H/24H Clock
Setting
Return
• Press the
(Up/Down) buttons to select 12H
or 24H .
• The confirmation screen will appear when the
Menu/Enter button is pressed.
Note
By default, the time display is set to the 24H format.
3
No
Yes
12H/24H Clock
Save the settings?
Setting
Return
• Press the
(Left/Right) buttons to select Yes .
• Press the Menu/Enter button to confirm the setting
and to return to the Main Menu.
Operation Method
User reference guide
BRC0731A4
3P422724-1
39
Menu Manipulation
Language
�Select the Language
1
Setting
Return
Clock & Calendar
Language
2/2
Main Menu
• Display the Main Menu. (See "Manipulating the
Main Menu" on page 21).
• Press the
(Up/Down) buttons to select
Language and press the Menu/Enter button.
2
English
Language
Setting
Return
• Press the
(Up/Down) buttons to select the
preferred language.
• Press the Menu/Enter button to confirm the
settings and to return to the Basic Screen.
Note
The visible languages are depending on the installed language pack.
For detailed information on the available languages and on how to change the language pack,
refer to the Installer reference guide.
Operation Method
User reference guide
40
BRC0731A4
3P422724-1
Caution
• Do not wash the remote
controller.
Doing so may cause electric
leakage and result in electric
shocks or fire.
• Be sure to stop the operation of
the air conditioner and turn off
the power supply breaker when
performing maintenance
activities.
Failure to do so may result in
electric shocks or injury.
Maintenance of Unit and the LCD display
Note:
• Wipe the LCD display and the rest of the surface of the remote controller with a dry cloth when
they become dirty.
• If the dirt on the surface cannot be removed, soak the cloth in neutral detergent diluted with
water, squeeze the cloth tightly, and clean the surface. Wipe the surface with a dry cloth
afterwards.
• Do not use any paint thinner, organic solvent or strong acid.
Warning
Do not use flammable materials (e.g., hair spray or insecticide) near the air
conditioner.
Do not clean the product with organic solvents such as benzine or paint
thinner.
The use of organic solvents may cause crack damage to the product, electric shocks
or fire.
Maintenance
User reference guide
BRC0731A4
3P422724-1
41
Error Code Display
�Contact your Daikin dealer in the following cases
Warning
When the air conditioner is malfunctioning (e.g., giving off a burning odor),
stop the air conditioner and turn off the power.
Continued operation under such circumstances may result in failure, electric shocks
or fire. Contact your Daikin dealer.
1
28°C
• If an error occurs, the error icon in the Basic
Screen and the operation lamp will blink.
• To display the error code and contact information,
the Menu/Enter button needs to be enabled (See
"Manipulating the Main Menu" on page 21 ).
• Press the Menu/Enter button.
Operation
lamp
2
Contact Info
0123–4567–8900
Error Code:A1
Return
• The error code blinks and the contact address will
appear.
• Notify your Daikin dealer of the Error code and
Model name.
Operation Method
Reference Information
User reference guide
42
BRC0731A4
3P422724-1
Reference Information
ʺMode Conflictʺ message
10°C
Mode conflict
Only applicable in case of a multi system (multiple indoor units
connected to the outdoor unit). When multiple indoor units are
instructed to operate simultaneously, but in different operation
modes, an operation mode conflict occurs:
• The operation lamp flashes
•
Mode conflict appears on the user interface
• The units that do not have priority enter standby mode
This is not a malfunction. To solve the conflict, make the units that do not have priority run in the
same operation mode as that of the unit that has priority. Which unit has priority depends on whether
the Priority Room setting is present and/or active:
If...
Then...
The Priority Room setting is present and
active.
The operation mode of the indoor unit to which
the Priority Room setting is applied takes
priority. In case of an operation mode conflict,
the other units will enter standby mode.
NOTICE
• COOL, DRY and FAN operation can be used simultaneously.
• If the conflict is not solved manually, non-priority units will automatically resume operation as
soon as the priority unit stops operating.
If...
Then...
The Priority Room setting is not present OR
present but not active.
The operation mode of the indoor unit that was
turned on first takes priority. In case of an
operation mode conflict, the units that were
turned on later will enter standby mode.
NOTICE
• COOL, DRY and FAN operation can be used simultaneously.
• Units running in HEAT operation mode always have priority over units running in FAN
operation mode, even if they were not turned on first.
• When solving the conflict, it is possible to make the non-priority units run in AUTO operation
mode: they will automatically start operation in the same operation mode as that of the
priority unit.
User reference guide
BRC0731A4
3P422724-1
43
Reference Information
Caution
The MODE CONFLICT can also happen to units that are turned on by the setback
function. This means that due to priority, they will not run and consequently will not be
able to maintain the temperature in the room. Please consider the use of the setback
feature in a multi system carefully to avoid situations like these.
Caution
When a KRP928 Interface adapter for Room Air Conditioner is connected, the mode
conflict message will not be shown on the user interface, but the indoor unit will go
into standby mode.
Combined use of the wired and wireless user interface
Avoid using the wired user interface and the standard wireless remote controller at the same time.
If you do so anyway, following phenomena may occur:
Phenomenon
Explanation
On the wireless user
interface
An incorrect unit status
(e.g. on/off, operation
mode, setpoint, fan
speed/direction) may
appear on the wireless
user interface display.
The wireless user interface does not receive feedback from the unit.
When a setting is changed (manually or automatically by a schedule)
on the wired user interface, the change is not communicated to the
wireless user interface.
Example
In case on/off was set by the wired user interface, the on/off status
shown on the wireless user interface will be incorrect. In this situation,
the user will need to push the wireless user interface on/off button
twice to achieve the required on/off setting change on the indoor unit.
At the same time, the setpoint, operation mode, and fan speed/
direction will be overwritten by the wireless user interface status.
On the wireless user
interface
When pushing a button,
all statuses of the
wireless user interface
display will be sent to the
indoor unit.
The wireless user interface sends all settings at once (e.g. on/off,
operation mode, setpoint, fan speed/direction, …) to the unit in case of
a setting change by any button.
When any button is pushed on the wireless user interface, all settings
(e.g. on/off, operation mode, setpoint, fan speed/direction, …) are sent
to the unit and settings set by the wired user interface are overwritten.
Example
In case the setpoint was set by the wired user interface, the setpoint
status shown on the wireless user interface will be incorrect. In this
situation, the user will overwrite the setpoint with the wireless setpoint
when pushing the setpoint up button on the wireless user interface.
At the same time, the on/off setting, operation mode, and fan speed/
direction will be overwritten by the wireless user interface status.
User reference guide
44
BRC0731A4
3P422724-1
Reference Information
Phenomenon
Explanation
On the wired user
interface
The status of some
functions (e.g. ECONO
mode, powerful mode,
indoor unit quiet
operation, outdoor unit
quiet operation, humidify)
is not shown on the wired
user interface display.
The wired user interface does not support the handling of these
functions.
In case one of these functions (e.g. ECONO mode, powerful mode,
indoor unit quiet operation, outdoor unit quiet operation, humidify) is
set on the wireless user interface, the activation is not shown on the
wired user interface.
ECONO mode set by wireless user interface
Not indicated on the wired user interface.
Stopping the unit by the wired user interface will cancel the ECONO
mode.
Powerful mode set by wireless user interface
Not indicated on the wired user interface.
Setpoint and fan speed change on the wired user interface will only
become valid when the powerful mode is stopped.
Stopping the unit or changing the operation mode on the wired user
interface will cancel the powerful mode.
Indoor unit quiet operation set by wireless user interface
Not indicated on the wired user interface, but auto fan speed is shown.
Changing the fan speed on the wired user interface will cancel the
indoor unit quiet operation mode.
Outdoor unit quiet operation set by wireless user interface
Not indicated on the wired user interface.
The outdoor unit quiet operation will never be cancelled by an action
on the wired user interface.
Comfort airflow operation set by wireless user interface
Not indicated on the wired user interface.
Changing the airflow direction on the wired user interface will cancel
the comfort fan operation.
“URURU” HUMIDIFY operation set by wireless user interface
No humidify symbol is indicated on the wired user interface, but
heating operation mode without heating setpoint is shown.
Changing the operation mode on the wired user interface will cancel
the “URURU” HUMIDIFY operation.
HUMID HEATING operation set by wireless user interface
Not indicated on the wired user interface, but heating operation mode
and setpoint are shown.
Changing the operation mode on the wired user interface will cancel
the HUMID HEATING operation.
User reference guide
BRC0731A4
3P422724-1
45
Reference Information
Phenomenon
Explanation
DRY COOLING operation set by wireless user interface
Cooling mode is indicated on the wired user interface.
Changing the operation mode on the wired user interface will cancel
the DRY COOLING operation.
Other functions (e.g. intelligent eye, radiant operation, …) set by
wireless user interface
Not indicated on the wired user interface.
Changing the operation mode on the wired user interface will not
affect the status of these functions.
A weekly schedule can
be programmed on the
wireless user interface
and executed by the
indoor unit.
At the same time, a
different weekly schedule
can be programmed on
the wired user interface
and executed.
The wireless user interface weekly schedule timer (based on the
wireless user interface clock) and the wired user interface weekly
schedule timer (based on the wired user interface clock) are 2
independent schedule timers.
To avoid conflicts, only the wired user interface schedule timer should
be used.
In case a weekly schedule timer was already set by the wireless user
interface, please first delete this weekly schedule timer before
proceeding.
On the wireless user
interface
It is possible to change
the on/off setting, setpoint
and operation mode,
even if the buttons are
locked on the wired user
interface.
The wireless user interface does not receive feedback from the unit.
The button lock function is a function of the wired user interface.
When a button is locked on the wired user interface, the lock is not
communicated to the wireless user interface.
In addition, a change on the wireless user interface will be executed
on the indoor unit and is not prevented. The actual unit status will
always be shown on the wired user interface display.
On the wireless user
interface
It is possible to change
the setpoint out of range,
even if a setpoint range is
set by the wired user
interface.
The wireless user interface does not receive feedback from the unit.
The setpoint range function is a function of the wired user interface.
When a setpoint range is set on the wired user interface, the new
range is not communicated to the wireless user interface.
In addition, a setpoint change on the wireless user interface will be
executed on the indoor unit and is not prevented. The actual unit
status setpoint will always be shown on the wired user interface
display.
User reference guide
46
BRC0731A4
3P422724-1
Reference Information
Phenomenon
Explanation
On the wireless user
interface
It is possible to set an
operation mode even
when this operation
mode is prohibited in the
wired user interface.
The wireless user interface does not receive feedback from the unit.
The operation prohibit function is a function of the wired user interface.
When an operation mode is prohibited on the wired user interface, this
is not communicated to the wireless user interface.
In addition, an operation mode change on the wireless user interface
will be set on the indoor unit and is not prevented. The actual unit
status operation mode will always be shown on the wired user
interface display.
On the wireless user
interface
Setback setpoints and
setback active can not
appear on the wireless
user interface display.
(Only when setback function is enabled)
The setback function is a function of the wired user interface.
The setback setpoints can only be set on the wired user interface
when the unit is turned off.
The setback function can only become active when the unit is turned
off.
The setback function turns the unit on under setback control and the
setback symbol is shown on the wired user interface.
The setback setpoints and function status are not communicated to
the wireless user interface.
A setpoint change on the wireless user interface will not modify the
setback setpoints. However, modified setpoints will become valid
when the unit is turned manually on again.
User reference guide
BRC0731A4
3P422724-1
47
Reference Information
After-sales Service
Warning
• Do not disassemble, modify or
repair the unit.
Doing so may result in electric
shocks or fire.
Consult your Daikin dealer.
• Do not relocate or reinstall the
remote controller by yourself.
Improper installation may result in
electric shocks or fire.
Consult your Daikin dealer.
�Advise the repairer of the following items
• Model name
• Date of installation
• Failure conditions: As precise as possible.
• Your address, name and telephone number
�Relocation
The relocation of the remote controller requires special equipment. Consult your Daikin dealer.
Actual expenses required for the relocation of the remote controller will be charged.
�Inquiry about After-sales Service
Contact your Daikin dealer.
DAIKIN AUSTRALIA PTY. LIMITED
-
, Chipping Norton, NSW 2170 Australia
Phone: 1300 78 72 66
www.daikin.com.au
Daikin New Zealand, 525 Great South Rd, Penrose, Auckland 6
Governor
Macquarie
62 66
Dr
Phone: 1300 36 24 38