Visonic MCW Installation Instructions

Specifications

Brand: Visonic
Category: Other
Model: MCW (Installation Instructions)
File Type: PDF
File Size: 0.4 Mb
Pages: 4

Read Online

Read the Visonic MCW Installation Instructions online using the built-in PDF viewer.

Text of the manual

Wireless PowerCode Digital PIR Detector

Installation Instructions 1. INTRODUCTION The NEXT MCW is a microprocessor-controlled wireless digital PIR detector, designed for easy installation, free of vertical adjustment. It features a cylindrical lens with uniform detection sensitivity throughout its operating range, up to 12 meters (40 ft), with wall creep zone protection. NEXT is a registered mark of Visonic Ltd. The advanced True Motion Recognition™ algorithm (patented) allows the NEXT MCW to distinguish between the true motion of an intruder and any other disturbances which may cause false alarms. An on-board motion event jumper determines whether 1 or 2 consecutive motion events trigger an alarm. The NEXT MCW includes the following features: • Incorporates a fully supervised PowerCode transmitter • Patented sophisticated motion analysis algorithm - True Motion Recognition (TMR™) • Sophisticated frequency domain digital signal processing • No vertical adjustment is needed • Programmable motion event counter • After detection, the detector disarms itself to save battery power. It rearms (reverts to the ready state) if there is no subsequent detection throughout the following 2-minute period • An optional version provides better protection for systems compliant with DD243. After initial detection, the detector is capable of 7 additional detections for a period of 5 minutes. Further detection is possible only if no movement occurs during the following 2 minutes. The detector will revert to the initial state if there is no movement for an additional 5 minutes. • Very low current consumption • Microprocessor-controlled temperature compensation • Sealed chamber protects the optical system • Front cover tamper switch. • Back tamper switch (option) • White light protection • Elegantly styled, sturdy case Figure 1. General View Figure 2. Inside View For UL installations: The detector is for use with UL listed control unit PowerMax+ only. 2. SPECIFICATIONS OPTICAL Detector Type: Dual element low- noise pyroelectric sensor. Lens Data No. of Curtain Beams: 9 + 5 Max. Coverage: 12 x 12 m (40 x 40 ft) / 90° ELECTRICAL Internal Battery: 3V Lithium battery, type CR-123A. For UL installations, use Panasonic or Sanyo only. Nominal Battery Capacity: 1450 mA/h. Standby Current Drain: approx. 0.025 mA. Transmit Current Drain: 20 mA (including LED). Battery Life (with LED on): Typically over 3 years. Figure 3. Maximum Coverage Pattern Battery Power Test: Performed immediately upon battery insertion and periodically after every several hours. FUNCTIONAL True Motion Event Verification: 2 position selector - 1 (OFF) or 2 (ON) motion events. Alarm Period: 3 seconds. Visual Indications: LED Lights for about 3 seconds upon transmission of alarm & tamper messages and upon motion detection in the walk test mode. LED Flashes during the power-up stabilization period, or after restoring (pressing) the tamper switch. LED Does not light upon transmission of supervision messages. Rearm Timer: Rearms the detector 2 minutes after the last alarm. Timer disabled in the walk test mode – not applicable for the DD243 version (see section 1). WIRELESS Frequency (MHz): 315 (U.S. version), 433.92, 868.95, 869.2625 or other frequencies according to local requirements. Transmission Sequence: 3 data bursts at variable intervals within 3 seconds. Encoding: 24-bit ID, over 16 million possible combinations. Total Message Length: 36 bits. Tamper Alert: Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored. Supervision Message: Signaling at 60-minute intervals (U.S. version) or 15 minute interval (UK version), or according to the local standards. MOUNTING Height: 1.8 - 2.4 m (6 - 8 ft). Installation Options: Surface or corner. ACCESSORIES: BR-1: Surface mounted swivel bracket, adjustable 30° down and 45° left/45° right. BR-2: BR-1 with a corner adapter BR-3: BR-1 with a ceiling adapter ENVIRONMENTAL RFI Protection: >20 V/m up to 1000 MHz. Operating Temperatures: -10°C to 50°C (14°F to 122°F). Storage Temperatures: -20°C to 60°C (-4°F to 140°F). Compliance with Standards: Designed to meet FCC Part 15 and Directive 1999/5/EC of the European Parliament. EN 50131-2, Grade 2, Class II PHYSICAL Size (H x W x D): 94.5 x 63.5 x 53.0 mm (3-11/16 x 2-1/2 x 2-1/16”). Weight (with battery): 70 g (2.5 oz). Color: White. PATENTS: U.S. Patents 5,693,943 z 6,211,522 z D445,709 (another patent pending).

3.1 General Guidelines

3.2 Illustrated Installation Procedure RESET: With the battery in place, press both tamper switches simultaneously and release them. The LED at the front will flash for about 2 minutes until the detector stabilizes. Note: The de]tector transmits a low battery signal upon detection of low battery. Note: It is recommended to wait about 1 minute before inserting the new battery. A B BACK TAMPER SWITCH (OPTION) FRONT TAMPER SWITCH OBSERVE POLARITY ! ENROLL: Approach the control panel and enroll the detector’s ID into the control panel’s memory as shown in the panel’s installation manual. When required to transmit, press both tamper switches again and release them. You may enroll the detector’s ID while the detector’s LED flashes. USE A SCREWDRIVER TO PIERCE SURFACE OR CORNER KNOCK- OUTS, AS REQUIRED. A USE A LARGE DIAMETER DRILL BIT TO DE-BURR THE OTHER SIDE B SUPPORTS FOR BOTTOM EDGE OF PCB CORNER (2 OF 4) SURFACE (1 OF 2) BREAK-AWAY SEGMENT (BACK TAMPER SWITCH ACTUATOR - OPTION) TOP CATCH FOR PCB Attention! Lean the rear part of the break-away segment against a piece of wood while piercing its knockouts. B INSERT TWO DOWELS AND C INSERT THE BOTTOM EDGE D MARK TWO DRILLING A SINGLE- SIDE, 45° ANGLED MOUNT SURFACE MOUNT (1 OF 2) ATTACH THE BASE TO THE WALL WITH TWO SCREWS. OF THE LARGE P.C. BOARD UNDER THE TABS & PRESS THE TOP EDGE IN. POINTS AND DRILL HOLES IN WALL. SINGLE- SIDE, 45° ANGLED MOUNT BREAK-AWAY SEGMENT FOR TAMPER PROTECTION, THE BREAK-AWAY SEGMENT MUST BE ATTACHED TO WALL. 1.8 - 2.4 m (6 - 8 ft) above ground Attention! The unit has a back tamper switch (option) under the PCB. As long as the PCB is seated firmly within the base, the switch will be pressed against a metal spring piece attached to the base. Be sure to fasten the break-away segment to the wall with the screws going through the metal spring and the break-away base segment. If the detector is forcibly removed from the wall, this segment will break away from the base, causing the tamper switch to open and send a tamper alarm. 1 EVENT: FAST RESPONSE 2 EVENTS: HIGHEST FALSE ALARM PROTECTION ON: LED ENABLED OFF: LED DISABLED IMPORTANT! INSTRUCT THE USER TO WALK- TEST AT LEAST ONCE A WEEK TO ASSURE PROPER FUNCTION OF EACH DETECTOR. B WALK ACROSS THE FAR END OF COVERAGE PATTERN IN BOTH DIRECTIONS. THE INDICATOR SHOULD LIGHT FOR 2-3 SECONDS EACH TIME YOUR MOTION IS DETECTED. C A MOUNT THE COVER, CLOSE IT AND TIGHTEN THE SCREW. WAIT FOR THE DETECTOR TO STABILIZE (THE LED STOPS FLASHING). 1 2 3 Note: After closing the cover the detector enters a 15 minute walk-test mode. In this mode the LED will flash each time a detection occurs, regardless of LED jumper settings, and the detector will transmit on the occurrence of each event. 1 2 3 4 Open holes in the base Disassemble the unit Install the battery Mount the base 6 5 Set the jumpers as needed Walk-test the coverage area

LED Functions Summary

LED Jumper Position First 2-3 Minutes After Closing Cover Within 15 Minutes After Closing Cover - "Walk Test Mode" More than 15 Minutes After Closing Cover - "Normal Mode" ON LED Flashes LED lights and the unit sends RF alarm signal on every detection LED lights, the unit sends RF alarm signal and enters 2 minutes sleep mode. OFF LED Flashes LED lights and the unit sends RF alarm signal on every detection LED does not light! Unit sends RF alarm signal and enters 2 minutes sleep mode. 4. SPECIAL COMMENTS 4.1 Product Limitations Visonic Ltd. wireless systems are very reliable and are tested to high standards. However, due to their low transmitting power and limited range (required by FCC and other regulatory authorities), there are some limitations to be considered: A. Receivers may be blocked by radio signals on or near their operating frequencies, regardless of the code selected. B. A receiver can only respond to one signal at a time. C. Wireless equipment should be tested regularly to determine whether there are sources of interference and to protect against faults. D. Even the most sophisticated detectors can sometimes be defeated or may fail to warn due to: DC power failure / improper connection, malicious masking of the lens, tampering with the optical system, decreased sensitivity in ambient temperatures near that of the human body and unexpected failure of a component part. The above list includes the most common reasons for failure to detect intrusion, but is by no means comprehensive. It is therefore recommended that the detector and the entire alarm system be checked weekly, to ensure proper performance. E. An alarm system should not be regarded as a substitute for insurance. Home and property owners or renters should be prudent enough to continue insuring their lives and property, even though they are protected by an alarm system. 4.2 Compliance with Standards The 315 MHz version of this device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The digital circuit of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: – Re-orient or re-locate the receiving antenna. – Increase the distance between the device and the receiver. – Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. – Consult the dealer or an experienced radio/TV technician. 4.3 Frequency Allocations for Wireless Devices in European (EU) Countries • 315 MHz is not allowed in any EU member state. • 433.92 MHz has no restriction in any EU member state. • 868.95 MHz (wide band) is allowed in all EU member states. • 869.2625 MHz (narrow band) is not restricted in any EU member state. 4.4 Battery Handling A. Replace battery ONLY with recommended battery (see specifications). B. Dispose used batteries according to their manufacturer's instructions. WARRANTY Visonic Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants its products hereinafter referred to as "the Product" or "Products" to be in conformance with its own plans and specifications and to be free of defects in materials and workmanship under normal use and service for a period of twelve months from the date of shipment by the Manufacturer. The Manufacturer's obligations shall be limited within the warranty period, at its option, to repair or replace the product or any part thereof. The Manufacturer shall not be responsible for dismantling and/or reinstallation charges. To exercise the warranty the product must be returned to the Manufacturer freight prepaid and insured. This warranty does not apply in the following cases: improper installation, misuse, failure to follow installation and operating instructions, alteration, abuse, accident or tampering, and repair by anyone other than the Manufacturer. This warranty is exclusive and expressly in lieu of all other warranties, obligations or liabilities, whether written, oral, express or implied, including any warranty of merchantability or fitness for a particular purpose, or otherwise. In no case shall the Manufacturer be liable to anyone for any consequential or incidental damages for breach of this warranty or any other warranties whatsoever, as aforesaid. This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to act on its behalf in the modification, variation or extension of this warranty. This warranty shall apply to the Product only. All products, accessories or attachments of others used in conjunction with the Product, including batteries, shall be covered solely by their own warranty, if any. The Manufacturer shall not be liable for any damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or otherwise, caused by the malfunction of the Product due to products, accessories, or attachments of others, including batteries, used in conjunction with the Products. The Manufacturer does not represent that its Product may not be compromised and/or circumvented, or that the Product will prevent any death, personal and/or bodily injury and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all cases provide adequate warning or protection. User understands that a properly installed and maintained alarm may only reduce the risk of events such as burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such will not occur or that there will be no death, personal damage and/or damage to property as a result. The Manufacturer shall have no liability for any death, personal and/or bodily injury and/or damage to property or other loss whether direct, indirect, incidental, consequential or otherwise, based on a claim that the Product failed to function. However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, the Manufacturer's maximum liability shall not in any case exceed the purchase price of the Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the Manufacturer. Warning: The user should follow the installation and operation instructions and among other things test the Product and the whole system at least once a week. For various reasons, including, but not limited to, changes in environmental conditions, electric or electronic disruptions and tampering, the Product may not perform as expected. The user is advised to take all necessary precautions for his/her safety and the protection of his/her property. 6/91

VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788

VISONIC INC. (U.S.A.): 10 NORTHWOOD DRIVE, BLOOMFIELD CT. 06002-1911. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094 VISONIC LTD. (UK): FRASER ROAD, PRIORY BUSINESS PARK, BEDFORD MK44 3WH. PHONE: (0870) 730-0800 FAX: (0870) 730-0801 INTERNET: www.visonic.com VISONIC LTD. 2004 NEXT MCW DE3591- (REV. 3, 01/04) R