Mastech MS2203 Operation & User’s Manual
File Specifications
| Brand: | Mastech |
| Category: | Measuring Instruments |
| Model: | MS2203 (Operation & User’s Manual), prkVHhF0W2gMg |
| File Info: | Adobe Acrobat PDF (DjVu) |
| File Size: | — |
| Pages: | 36 pages |
Download PDF
Download Mastech MS2203 Manual (36 pages)Read Online:
Read the Mastech MS2203 Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.
Key Pages of Document
* Operating temperature: 0℃~40℃
* Dimension size: 300mm×103mm×51mm * Weight: approx. 500g ( include battery ) ACCESSORIES Users manual 1 Battery 1.5V AA 4 Test Leads (MS3000) 1 Connect test clamp (MS3102) 1 RS232C interface cable ( MS3403 ) 1 PC Data Record graph software 1 Carry Case 1 - 32 - ...
Recording Voltage value、current value、Active Power value to calculate
Reactive Power value, The calculating accuracy is 0.01% of the range. ACTIVE ENERGY (kWh) RANGE ACCURACY RESOLUTION 1~9999kWh ±(3%+2) 0.001kWh Minimum measurement current : 0.5A Minimum measurement voltage : 10V - 31 - FREQUENCY ( Hz ) RANGE ACCURACY RESOLUTION 20Hz~1kHz 0.5% 0.1Hz Minimum measurement voltage: 20V * Accuracy:% of reading + number of digits The specification given assume an operating temperature: 18℃~28℃,humidity up to: 80% , the frequency of vol ...
Minimum measurement voltage : 20V
APPARENT POWER (VA) RANGE ACCURACY RESOLUTION 4kVA ±(3%+5) 0.01kVA 10kVA ±(3%+5) 0.01kVA 40kVA ±(3%+5) 0.01kVA 100kVA ±(3%+5) 0.01kVA 600kVA ±(3%+5) 0.1kVA Minimum measurement current : 5A Minimum measurement voltage : 20V - 30 - POWER FACTOR (PF) RANGE ACCURACY RESOLUTION 0.3~1 Capacitive ±(0.02+2) 0.001 0.3~1 Inductive ±(0.02+2) 0.001 Minimum measurement current : 5A Minimum measurement voltage : 20V REACTIVE POWER (Var) 2=(VA) 2+W 2 RANGE ACCURACY RESOLUTION 4kVAr ±(4%+5) 0.01 ...
single-phase circuit (Active Power, Power Factor, Apparent Power,
Reactive Power, Active Energy): ( 1. ) Active Power(kW) and Power Factor (PF) (Figure 8 ) a. Press kW / PF button, the Active Power value is shown in the primary display and the Power Factor value, “PF” symbol are shown in the secondary display. When the Power Factor value is negative, the loading is capacitive. - 15 - b. The maximum measurement range of Active Power is 600kW. For exceeding the maximum value, the “OL” symbol will be shown in the display. If test voltage exceeds 600V or the test current exceeds 1000A, ...
Minimum Value Button/ Next Record Button
12 SAVE Data Save Button – 6 – 1. kW / PF Active Power, Power Factor Measurement Button Press kW / PF button to measure Active Power and Power Factor in measurement mode. Then the LCD shows Active Power reading in the primary display and Power Factor reading in the secondary display. 2. kVAr kVA Apparent power, Reactive Power measurement button Press kVAr kVA button to measure Apparent Power and Reactive Power in measurement mode. Then the LCD shows Apparent Power reading in the primary display and Reactive Power reading in the secondary ...
Recording Voltage value、current value、Active Power value to calculate
Reactive Power value, The calculating accuracy is 0.01% of the range. ACTIVE ENERGY (kWh) RANGE ACCURACY RESOLUTION 1~9999kWh ±(3%+2) 0.001kWh Minimum measurement current : 0.5A Minimum measurement voltage : 10V - 31 - FREQUENCY ( Hz ) RANGE ACCURACY RESOLUTION 20Hz~1kHz 0.5% 0.1Hz Minimum measurement voltage: 20V * Accuracy:% of reading + number of digits The specification given assume an operating temperature: 18℃~28℃,humidity up to: 80% , the frequency of vol ...
( Figure 23. Open The Battery Cover )
- 28 - When the LCD displays the “ ” symbol, the batteries must be replaced to maintain proper operation. Use the following procedure to replace the batteries: 1. Disconnect test leads from any signals, turn the rotary function switch to OFF, and remove the test leads from the input terminals. 2. Open the battery cover and remove the battery cover. Because there is a locked design in the battery cover. Don’t force the battery cover open, otherwise the cover is broken. Refer to Figure 23 for opening it: Insert a coin into the groove of th ...
Mastech MS2203 user guide recommended for: MS8239D, MS2128A, MAS838, MS8321B, MS8239C.
⚠️ Download Safety
The Measuring Instruments Operation & user’s manual (36 pages) is completely safe to download (last scan date: 30/04/2026).
Related PDF Instructions for Mastech MS2203:
-
Mastech MS8218 Multimeter Operation & user’s manual
MS821846 -
Mastech MS8239D Measuring Instruments Operator's manual
MS8239D12 -
Mastech MS6540A Thermometer Operation & user’s manual
MS6540A9 -
Mastech MS7222 Test Equipment Operating instructions
MS72222 -
Mastech MS8238H Multimeter Operation & user’s manual
MS8238H12 -
Mastech MS6530T Thermometer Operation manual
MS6530T9
Measuring Instruments Equipment: Frequently Requested
-
Endress+Hauser Liquiline M CM42 Measuring Instruments
19.02.2026Maintenance instructions for the Endress+Hauser Liquiline M CM42 Measuring Instruments. This documentation outlines replacement parts, diagnostic information, operation.Liquiline M CM42, 32 -
National Instruments NI 9219 Measuring Instruments
31.01.2026Maintenance instructions for the National Instruments NI 9219 Measuring Instruments. It describes operating procedures and internal layout, supported accessories, setup guidelines, detailing setup.NI 9219, 38 -
LaserLiner SensoLite 120 Measuring Instruments
26.02.2026Full operation manual for the LaserLiner SensoLite 120 Measuring Instruments. It details operating modes and product maintenance, supported accessories, technical guidelines.SensoLite 120, 56 -
Evoqua WALLACE & TIERNAN GMS PLUS Measuring Instruments
19.01.2026Comprehensive instruction manual for the Evoqua WALLACE & TIERNAN GMS PLUS Measuring Instruments. The guide outlines procedures for cleaning instructions, compatibility information, safety information, software installation.WALLACE & TIERNAN GMS PLUS, 116 -
Instron 2630-100 Series Measuring Instruments
05.05.2026Device guide for the Instron 2630-100 Series Measuring Instruments. The guide provides instructions on installation guides, operational guidelines, detailing setup, software installation.2630-100 Series, 66 -
FLIR CM94 Measuring Instruments
07.11.2025Device guide for the FLIR CM94 Measuring Instruments. The documentation includes operating guidelines, maintenance, diagnostic information, daily usage.CM94, 38
Have some Questions about Mastech MS2203 Device?
Get valuable and actionable advices from other Mastech MS2203 device users. Describe your problem or question, regarding the using of MS2203, in as much detail as possible, and other users will be able to answer you.