Key Pages of Document

* Operating temperature: 0℃~40℃

* Dimension size: 300mm×103mm×51mm * Weight: approx. 500g ( include battery ) ACCESSORIES Users manual 1 Battery 1.5V AA 4 Test Leads (MS3000) 1 Connect test clamp (MS3102) 1 RS232C interface cable ( MS3403 ) 1 PC Data Record graph software 1 Carry Case 1 - 32 - ...

Recording Voltage value、current value、Active Power value to calculate

Reactive Power value, The calculating accuracy is 0.01% of the range. ACTIVE ENERGY (kWh) RANGE ACCURACY RESOLUTION 1~9999kWh ±(3%+2) 0.001kWh Minimum measurement current : 0.5A Minimum measurement voltage : 10V - 31 - FREQUENCY ( Hz ) RANGE ACCURACY RESOLUTION 20Hz~1kHz 0.5% 0.1Hz Minimum measurement voltage: 20V * Accuracy:% of reading + number of digits The specification given assume an operating temperature: 18℃~28℃,humidity up to: 80% , the frequency of vol ...

Minimum measurement voltage : 20V

APPARENT POWER (VA) RANGE ACCURACY RESOLUTION 4kVA ±(3%+5) 0.01kVA 10kVA ±(3%+5) 0.01kVA 40kVA ±(3%+5) 0.01kVA 100kVA ±(3%+5) 0.01kVA 600kVA ±(3%+5) 0.1kVA Minimum measurement current : 5A Minimum measurement voltage : 20V - 30 - POWER FACTOR (PF) RANGE ACCURACY RESOLUTION 0.3~1 Capacitive ±(0.02+2) 0.001 0.3~1 Inductive ±(0.02+2) 0.001 Minimum measurement current : 5A Minimum measurement voltage : 20V REACTIVE POWER (Var) 2=(VA) 2+W 2 RANGE ACCURACY RESOLUTION 4kVAr ±(4%+5) 0.01 ...

single-phase circuit (Active Power, Power Factor, Apparent Power,

Reactive Power, Active Energy): ( 1. ) Active Power(kW) and Power Factor (PF) (Figure 8 ) a. Press kW / PF button, the Active Power value is shown in the primary display and the Power Factor value, “PF” symbol are shown in the secondary display. When the Power Factor value is negative, the loading is capacitive. - 15 - b. The maximum measurement range of Active Power is 600kW. For exceeding the maximum value, the “OL” symbol will be shown in the display. If test voltage exceeds 600V or the test current exceeds 1000A, ...

Minimum Value Button/ Next Record Button

12 SAVE Data Save Button – 6 – 1. kW / PF Active Power, Power Factor Measurement Button Press kW / PF button to measure Active Power and Power Factor in measurement mode. Then the LCD shows Active Power reading in the primary display and Power Factor reading in the secondary display. 2. kVAr kVA Apparent power, Reactive Power measurement button Press kVAr kVA button to measure Apparent Power and Reactive Power in measurement mode. Then the LCD shows Apparent Power reading in the primary display and Reactive Power reading in the secondary ...

Recording Voltage value、current value、Active Power value to calculate

Reactive Power value, The calculating accuracy is 0.01% of the range. ACTIVE ENERGY (kWh) RANGE ACCURACY RESOLUTION 1~9999kWh ±(3%+2) 0.001kWh Minimum measurement current : 0.5A Minimum measurement voltage : 10V - 31 - FREQUENCY ( Hz ) RANGE ACCURACY RESOLUTION 20Hz~1kHz 0.5% 0.1Hz Minimum measurement voltage: 20V * Accuracy:% of reading + number of digits The specification given assume an operating temperature: 18℃~28℃,humidity up to: 80% , the frequency of vol ...

( Figure 23. Open The Battery Cover )

- 28 - When the LCD displays the “ ” symbol, the batteries must be replaced to maintain proper operation. Use the following procedure to replace the batteries: 1. Disconnect test leads from any signals, turn the rotary function switch to OFF, and remove the test leads from the input terminals. 2. Open the battery cover and remove the battery cover. Because there is a locked design in the battery cover. Don’t force the battery cover open, otherwise the cover is broken. Refer to Figure 23 for opening it: Insert a coin into the groove of th ...

Mastech MS2203 user guide recommended for: MS8239D, MS2128A, MAS838, MS8321B, MS8239C.

⚠️ Download Safety

The Measuring Instruments Operation & user’s manual (36 pages) is completely safe to download (last scan date: 30/04/2026).

Related PDF Instructions for Mastech MS2203:

Measuring Instruments Equipment: Frequently Requested

Have some Questions about Mastech MS2203 Device?

Get valuable and actionable advices from other Mastech MS2203 device users. Describe your problem or question, regarding the using of MS2203, in as much detail as possible, and other users will be able to answer you.