12.3 Setting Functions

196 Data Save Settings (save methods for time series data and event data) Data save area Always saves data in the internal memory (when a PC card is connected, saves data on the PC card as well) Settings when the data save area is full STOP/ LOOP (When “LOOP” is set: Time series data in internal memory: first in first out, event data: the worst event data is overwritten) External Interface Settings RS-232C output point printer/modem/OFF (The LAN may be used when modem is not set as the output point.) RS-232C settings Baud rate (bps): 9600, 19200, 38400, 57600, 1152 ...

12.1 Product Specifications

180 Input Specifications Measurement line type One single-phase 2-wire (1P2W), single-phase 3-wire (1P3W), three-phase 3-wire (3P3W2M,3P3W3M) or three-phase 4-wire (3P4W) plus one extra in- put channel Input channels Voltage: Four channels U1 to U4 (extra channel U4 can measure AC or DC) Current: Four channels I1 to I4 Input methods Voltage: Isolated inputs and differential operation Between U1,U2 and U3: these channels are not isolated from one another Between U1 to U3 and U4: channel U4 is isolated Current: input is isolated by the clamp-on sensor (voltage input ...

7.6 Analyzing Transient Waveforms

133 Scrolling through transient waveforms SCROLL Scroll through the waveform Scroll bar Waveform display range All recorded data (4 ms) The waveform display range (white belt) on the scroll bar indicates what interval of recorded data is displayed on the screen. When you scroll horizontally, you can check all the saved waveform. When you scroll vertically, you can change the offset posi- tion of the displayed waveform. Return to event list ...

5.1 Using the VIEW Screen

66 Screen operations depending on the internal operation status The screens that can be displayed differ depending on the internal operation status. Screen display during [SETTING] or [RECORDING]: Indicates the screen being displayed for the current measurement. Screen display during [ANALYZING]: Indicates the analysis screen being displayed for the selected event. Internal opera- tion status Display Display update [SETTING] Contents of the display update during set- ting. Approxi- mately 1 second [RECORDING] Contents of the latest display update dur- ing measurement ...

2.2 Screen Names and Configurations

29 Displays a voltage fluctuation graph used to calculate the swell, dip, and in- terruption. Voltage is calculated for one waveform shifted over half a wave. The maximum and minimum values are detected from the multiple voltage values included in the set interval, and the display changes. You can also display S(t) (when IEC flicker is selected) or ΔU (when DV10 flicker is selected), either of which indi- cates the voltage deviation with re- spect to nominal voltage. INTERVAL 6.4 "Changes in Voltage"(page 93) VOLTAGE TIME PLOT Screen Press to switch the di ...

12.1 Product Specifications

179 The specifications below apply to the 3196 POWER QUALITY ANALYZER. For the product specifications of the EN50160, see the Instruction Manual for EN50160. SpecificationsChapter 12 12.1 Product Specifications Environmental and Safety Specifications Operating environment Indoors, altitude up to 2000 m (6562-ft.) Storage temperature and humidity -20°C to 50°C (-4°F to 122°F), 80% RH or less (no condensation) Operating temperature and humidity 0°C to 40°C (32°F to 104°F), 80% RH or less (non-condensating) In the temperature range -10°C to 0°C(14°F to 32° ...

2.2 Screen Names and Configurations

21 You can make basic measurement set- tings for the following. • Connection method • Voltage and current ranges • PT and CT ratios • Clamp sensor • Nominal voltage • Measured frequency • PLL source • Calculation method • Flicker • EN50160 and so on MEASURE 4.3.1 "Main Settings"(page 49) RECORDING 6.2 "Time Plot Settings"(page 81) Press to switch the display screen. You can make recording settings for the following. • TIME PLOT (time series) data selec- tion • Measurement interval • Auto-save to the PC card • Real-time control � ...

Hioki 3196 user guide recommended for: 2300 Smart Site, 7016, 3664, CM4002, PQ3198.

⚠️ Download Safety

The Measuring Instruments Instruction manual (240 pages) is completely safe to download (last scan date: 12/05/2026).

Related PDF Instructions for Hioki 3196:

Measuring Instruments Equipment: Frequently Requested

Have some Questions about Hioki 3196 Device?

Get valuable and actionable advices from other Hioki 3196 device users. Describe your problem or question, regarding the using of 3196, in as much detail as possible, and other users will be able to answer you.