Text of the manual

• Sensor and magnet

• 4 screws Product Description The Door/Window Sensor helps provide energy savings for an area by detecting when a door or window opens or closes. It is a wireless solar-powered sensor that can be used on its own to detect the open and closed status of entry doors or windows, or it can be linked with occupancy sensors to more accurately track when a room is occupied or vacant. The sensor is easy to install on door and window frames, and virtu- ally anything indoors that opens and closes. Features Include: • Sends wireless message to other devices whenever a door or win- dow opens or closes • Harvests ambient solar energy to power the sensor and send wire- less communication • Mounts easily on standard doors or windows • Works with motion sensors to track room occupancy • Supplemental battery option for extreme low-light conditions Specifications Power Supply Indoor light energy harvesting (Optional) Supplemental battery Transmission Range 80 ft. (25 m) RF Communications EnOcean 902MHz (WDWS-EN3) Charge Time before Linking 2.7 hours @ 10 lux 3.7 minutes @ 200 lux Light Required to Sustain Operation 15 lux for 6 actuations/hour 50 lux for 30 actuations/hour 100 lux for 60 actuations/hour Charge Time for Full Charge 21 hours @ 200 lux (after startup) 42 hours @ 200 lux (cold start) Operating Life in Darkness (after full charge) 174 hours: heartbeat only 67 hours @ 10 actuations/hour 10 hours @ 100 actuations/hour EEP (EnOcean Equipment Profile) D5-00-01 Maximum Sensor Gap 0.25 inch (6.4 mm) Dimensions (Sensor) 3.15” L x 0.83” W x 0.59” D (80 mm x 21 mm x 15 mm) Dimensions (Magnet) 3.15” L x 0.47” W x 0.5” D (80 mm x 12 mm x 13 mm) Weight (Total) 0.97 oz. (27.5 g) Environment • Indoor use only • 32° to 131° F (0° to 55° C) • 5% to 95% relative humidity (non-condensing) Agency Compliance FCC, IC Planning Take a moment to plan for the sensor’s successful operation and optimal communication with other system components. Remove the sensor from its packaging and place it under a strong light to charge it for installation. • Ensure the location provides consistent and adequate light • Install according to the alignment requirements • Determine which sensor profile is appropriate (when linking with EnOcean-based In-line Switch, Plug-in Switch or HVAC Setback Mod- ules (refer to the “Linking” and “Sensor Profiles” sections) - otherwise; when linking with 3rd party controllers, these profiles aren’t relevant Consider the construction materials, such as metal and concrete, in the space and obstacles that may interfere with RF signals Tools Required • Screwdriver • Leveling tool • Light meter Page 1 0.83” 21mm 0.47” 12mm 0.59” 15mm 3.15” 80mm 0.5” 12.7mm Solar Panel Link Button Alignment Arrow (Sensor) Alignment Arrow (Magnet) LED Display 1. • WDWS-EN3 Installation Guide B1877 393233B • 07.18.17

The proximity of the magnet to the sensor is important for proper

detection. The alignment arrows on the sensor and the magnet must point to each other and the gap between them must not exceed .25 inch (6.4mm) in any direction. Alignment Guidelines gap is 1/4” (6.4mm) or less misaligned arrows gap is too wide Front View End View Installing 1. Based on your requirements, decide where you want to install the sensor and the magnet. For door installations, locate the sensor: • On the knob side of the door jamb, away from hinges. • At least 1 ft. (30 cm) above the floor to avoid damage. For window installations, make sure the location does not ex- pose the sensor to contact with water. 2. Follow the alignment requirements that are described in the Planning section. NOTE: For easy access and handling, it is recommends that the sensor be linked to a transceiver before installing it, see the Link- ing section. 3. Install the sensor on the interior side of the fixed frame. A. Remove the mounting bracket from the sensor. Tab lock Notch Tab lock Notch B. Position the mounting bracket and mark the two mounting screw drill points. C. Insert the first screw loosely and level the mounting bracket. Notches Notches D. Install the second screw, and then hand-tighten the first screw. E. Snap the sensor onto the mounting bracket where the notches are located. Tab lock Tab lock F. Slide the sensor on the bracket until it snaps into place on the tab lock. 4. Install the magnet on the moving part of the door or window. A. Use a screwdriver to press the tab lock and flex the magnet cover to remove it. Tab lock Tab lock The cover is removed from the magnet body. Door/Window Sensor • Installation Guide Page 2 2. estimated time: 20 minutes

B. The two mounting

holes are exposed. C. Position the magnet with the proper spacing and alignment, and then install it with the provided screws. D. Replace the magnet cover and snap it into place on the tab lock. NOTE: For low activity applications, the magnet can be mounted with double-sided tape (not included). 5. Check the alignment arrows and the distance between the sen- sor and magnet when the door or window is closed. TIP: There is a faintly audible click when the sensor and magnet close and open. Linking Two or more EnOcean-based devices can be linked and configured to provide the desired control. There are two basic types of devices in the system; transmitters and transceivers. • Transmit-only: Transmitters are simple energy-harvesting devices that send RF messages to communicate a condition, level, or state. Transmitters can only be linked to transceivers. Examples > Self-powered Light Switches, Occupancy Sensors • Transmit & Receive: Transceivers are controlling devices that send as well as receive RF messages. They also process relevant control logic, and actuate the appropriate outputs (switching a light on or off for example). Transceivers can be linked with transmitters as well as other transceivers. A transceiver can have up to 30 devices linked to it. Examples > Relays, Gateways Cover Mounting Holes Cover Mounting Holes Fixed Frame Moving Part Fixed Frame Moving Part The Door/Window Sensor is a Transmit-only Device. To link the Door/Window Sensor to a transceiver; the transceiver must first be powered, within wireless range, and set to accepts links. Next, the desired transmitter, or another transceiver, is triggered to send a special link message. The awaiting transceiver receives and stores the link permanently so the devices can interact to provide a variety of intelligent control options. Sensor Profiles The sensor profile determines how the sensor is used within the sys- tem, whether it is for occupancy detection, HVAC control, or single load control. How the sensor interacts with other devices depends on where it is installed and how it is linked. There are three sensor profiles. NOTE: These profiles are supported for linking with EnOcean EISM (In-line Switch), EPSM (Plug-in Switch), and EHSM (HVAC Setback) controllers. Consult the manual for the respective controllers to determine the capabilities of the solution. Entry Door - for Occupancy Detection For this profile, the sensor is installed on an entry door and operates with a motion sensor as follows: Door Opens Door Closes The door/window ajar timer starts. If the timer runs out, shutdown mode is activated on the HVAC system. The door/window ajar timer is reset if all monitored doors and windows are closed. The vacancy check timer starts, if the motion sensor detects occupancy, normal mode is activated on the HVAC system. Window or Patio Door for HVAC Control For this profile, the sensor is installed on a window or patio door and operates as follows: Window Opens Window Closes The door/window ajar timer starts. If the timer runs out, shutdown mode is activated on the HVAC system. The door/window ajar timer is reset if all monitored doors and windows are closed. Normal mode is activated on the HVAC system. Closet Door for Single Load Control For this profile, the sensor is installed on a closet door and operate as follows because it is the only linked device: Door Opens Door Closes The switched auto-off timer starts and the light turns on. If the timer runs out the light turns off. The light turns off. Door/Window Sensor • Installation Guide Page 3 3.

To Link or Unlink a Sensor

When a Door/Window Sensor is linked, the position of the magnet indicates to the transceiver which type of sensor profile is being used. 1. Set the desired transceiver to Accept a Link. 2. Do one of the following according to the desired profile: A. Entry door for occupancy detection, place the magnet be- side the sensor (closed position). B. Window or patio door for HVAC control, move the magnet way from the sensor (open position). C. Closet door for single load control, move the magnet away from the sensor (open position). 3. Press the Link button on the sensor once. The Set button on the transceiver will be solid green for 3 seconds. The device is now linked. Installing Supplemental Battery (optional) If the sensor is installed where the light levels are consistently too low or there are days of darkness, battery power can be used to supplement the solar energy harvester. Only use a CR1216 battery. 1. Press the tab lock to release the sensor from the mounting bracket. 2. Slide the sensor about ½” (1 cm) and remove it from the mounting plate. 3. Insert the battery with the positive pole (+) up and slide it between the two contact terminals with your finger. WARNING: Ensure the battery is properly oriented. Improper handling of lithium batteries may result in heat generation, explosion, or fire. 4. Replace the sensor on the mounting plate and slide it until it snaps into place. 5. Open and close the contact to test for power. 6. There should be a faintly audible click and a fast LED blink. Tab lock Notch Tab lock Notch Contact Terminals Contact Terminals Troubleshooting Problem Solution Checklist The sensor does not generate a wireless message • Verify there is a faintly audible click when the con- tact is closed and opened • Verify the LED blinks once when the contact is closed and opened • Verify the solar cell is charged properly • Check that the magnet is oriented to the sensor- properly • Check that the alignment arrows are not spaced more than .25 inch (6.4 mm) The linked device does not respond to wireless messages • Check for environment or range issues. Tip: Re- orienting the sensor may overcome adverse RF conditions • Verify the device is linked • Check the transceiver connection and the wiring for errors • Check if appropriate devices are linked according to good system planning 902 MHz: Contains: FCC: SZV-STM320U IC: 5713A-STM320U This device complies with part 15 of the FCC rules and Industry Canada ICES-003. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélec- trique subi, meme si le brouillage est susceptible d’en compromettre le fonctionnement. IMPORTANT! Tous les changements ou modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de l’utilisateur pour actioner cet équipment. Door/Window Sensor • Installation Guide Page 4