Beater Door Assembly - Shake Side (See Figure 13)

ITEM PART NO. DESCRIPTION QTY. FUNCTION WARR. CLASS 1 032560 Seal-Drive Shaft 1 Provides seal from product inside freezing cylinder to internal areas of freezer. 000 2 050985 Shaft-Beater 7 Qt. Fluted Blade 1 Connects beater assembly to gear unit. 103 3 041103 Blade-Scraper-16” 2 Scrapes frozen product off wall of freezing cylinder. 000 4 055605 Bearing-Door Front 1.390 OD 1 Allows beater assembly to turn freely in hub of freezer door. 000 5 X50958 Beater A.-7 Qt. Fluted Blade 1 Blends air and mix inside the freezing cylinder and provides ...

The CURRENT CONDITIONS screen provides

the viscosity readings for the product when the side is running and hopper and barrel temperatures for both sides of the machine. The left column displays the readings for the shake side and the right column displays the sundae side readings. The bottom line in the display indicates the current glycol temperature. (See Figure 205.) VISC 0 0.0 HOPPER 41.0 41.1 GLYCOL 41.0 Figure 205 CURRENT CONDITIONS is the only Menu screen that will return the left and right side control panel keys to normal operation. The Menu keys will not be lit when this option is ...

Soft Serve Side

Probable Cause Either Side Probable Cause Corrective Action No control panel functions Machine is unplugged. Plug into wall receptacle. panel functions with power switch ON. Circuit breaker OFF or blown fuse. Turn the breaker ON or replace the fuse. The draw valve is not opening. The power switch is off. Place the power switch in the ON position. p g The shake side is in the STANDBY mode. Cancel the STANDBY mode. A heat cycle is in progress. Wait for the completion of the heat treatment cycle. The menu is displayed, making the flavor select ...

Install the duckbill valve into the syrup

nose fitting, with the flat end aligned with the open slot in the syrup nose fitting. Note: Replace the duckbill valve if it is damaged or extends past the syrup nose fitting slot. (See Figure 29.) Figure 65 16. Install the syrup nose fitting onto the syrup line fitting. Tighten by hand until snug. Note: The duckbill valve must be wet when the syrup nose fitting is assembled on the syrup line fitting. The sanitized water will lubricate the bottom flat surface and prevent the duckbill from twisting when the the syrup nose fitting is tightened. 17 ...

Insert the valve cap into the hole in the

mix inlet adapter. (See Figure 139.) 15111 Figure 139 8. Insert the mix inlet assembly into the pump cylinder. (See Figure 140.) 15112 Figure 140 The adapter must be positioned into the notch located at the end of the pump cylinder. 9. Secure the pump parts in position by sliding the retaining pin through the cross holes located at one end of the pump cylinder. (See Figure 141.) 15113 Figure 141 Note: The head of the retaining pin should be located at the top of the pump when installed. 10. Assemble the feed tube assembly. Slide the check ring in ...

Prepare another 2.5 gallons (9.5 liters) of

McD Sanitizer (HCS) solution. Use one packet in 2.5 gallons (9.5 liters) of water (100 PPM). 6. Pour the sanitizing solution into the mix hopper. 7. Brush the exposed sides of the hopper. Wait at least 5 minutes before proceeding with these instructions. 8. Touch the WASH symbol . This will cause the sanitizing solution in the freezing cylinder to be agitated. 9. With a pail beneath the door spout, open the draw valve and touch the PUMP symbol . Open and close the draw valve 6 times. Open the draw valve and draw off the sanitizing solution. 10. ...

Soft Serve Side

Probable Cause Either Side Probable Cause Corrective Action The product is too soft. Too much syrup - 1 fl oz (30 ml) in 5 seconds. For Triple Thick Shake Syrup: 1 oz (30 ml) ±1 1/8 oz (4 ml) in 7 seconds. Calibrate the syrups. Draw rate is set too fast. Adjust draw rate of 5 to 7 1/2 oz. (142 g. to 213 g.) of product by weight in 10 seconds. Outdrawing capacity of freezing cylinder. Allow unit to recover and cycle off before drawing more product. Air passage blocked in pump. Brush clean pump components and reassemble. Inadequate air space. ...

Taylor C602 user guide recommended for: H63, 161 SOFT, 772, 8756, 358.

⚠️ Download Safety

The Freezer Instruction manual (102 pages) is completely safe to download (last scan date: 04/04/2026).

Related PDF Instructions for Taylor C602:

Freezer Equipment: Frequently Requested

Have some Questions about Taylor C602 Device?

Get valuable and actionable advices from other Taylor C602 device users. Describe your problem or question, regarding the using of C602, in as much detail as possible, and other users will be able to answer you.