Taylor C152 Operator's Manual
Text of the manual
1/23/2017 (Original Publication)
(Updated 6/28/18)
OPERATOR’S
MANUAL
Model C152 & C161
Soft Serve Freezer
Original Service Instructions
085592-M
Complete this page for quick reference when service is required:
Taylor Distributor: __________________________________________________________
Address:_________________________________________________________________
Phone: __________________________________________________________________
Service: _________________________________________________________________
Parts: ___________________________________________________________________
Date of Installation: ________________________________________________________
Information found on the data label:
Model Number: ___________________________________________________________
Serial Number: ____________________________________________________________
Electrical Specs:
Voltage__________________ Cycle__________
Phase__________________________________
Maximum Fuse Size: ______________________________________________________ A
Minimum Wire Ampacity: ___________________________________________________ A
Note: Continuing research results in steady improvements; therefore, information in this manual is subject to change
without notice.
Note: Only instructions originating from the factory or its authorized translation representative(s) are considered to be
the original set of instructions.
© 2017 Taylor Company
085592-M
Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this work may be
a violation of copyright law of the United States of America and other countries, could result in the awarding of
statutory damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal
penalties. All rights reserved.
Taylor Company
750 N. Blackhawk Blvd.
Rockton, IL 61072
Table of Contents
085592-M
i
Section 1: To the Installer
Installer Safety ...................................................................................................1-1
Site Preparation .................................................................................................1-1
Air-Cooled Units.................................................................................................1-1
Water Connections.............................................................................................1-2
Electrical Connections........................................................................................1-2
Electrical Hookup Installation.............................................................................1-3
Beater Rotation ..................................................................................................1-3
Refrigerant .........................................................................................................1-3
Section 2: To the Operator
Operator Information..........................................................................................2-1
Section 3: Safety
Installer Information............................................................................................3-1
Section 4: Operator Parts Identification
Model C152........................................................................................................4-1
Model C161........................................................................................................4-2
C152 Beater Door Assembly..............................................................................4-3
C161 Beater Door Assembly..............................................................................4-4
C152 Accessories ..............................................................................................4-5
C161 Accessories ..............................................................................................4-6
Section 5: User Interface
C152...................................................................................................................5-1
C161...................................................................................................................5-1
Symbol Definitions .............................................................................................5-2
Power Switch .....................................................................................................5-2
MIX REF Key .....................................................................................................5-2
STANDBY Key...................................................................................................5-2
WASH Key .........................................................................................................5-3
AUTO Key..........................................................................................................5-3
Indicator Light—MIX LOW .................................................................................5-3
Indicator Light—MIX OUT..................................................................................5-3
Reset Button ......................................................................................................5-3
Feed Tube..........................................................................................................5-4
Section 6: Operating Procedures
Assembly............................................................................................................6-1
Sanitizing............................................................................................................6-5
Priming ...............................................................................................................6-6
Closing Procedure..............................................................................................6-7
Draining Product from the Freezing Cylinder .....................................................6-7
Rinsing ...............................................................................................................6-7
Cleaning .............................................................................................................6-7
Disassembly.......................................................................................................6-7
Brush Cleaning...................................................................................................6-8
Section 7: Operator Checklist
During Cleaning and Sanitizing..........................................................................7-1
Troubleshooting Bacterial Count........................................................................7-1
Regular Maintenance Checks ............................................................................7-1
Winter Storage ...................................................................................................7-2
Section 8: Troubleshooting Guide
Section 9: Parts Replacement Schedule
Maintenance Intervals ........................................................................................9-1
Section 10: Limited Warranty on Equipment
Section 11: Limited Warranty on Parts
To the Installer
1
To the Installer
The following information has been included in the
manual as safety and regulatory guidelines. For complete
installation instructions, please see the Installation
Checklist.
!
Installer Safety
IMPORTANT! In all areas of the world,
equipment should be installed in accordance with
existing local codes. Please contact your local authorities
if you have any questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and service
of Taylor® equipment.
•
Only authorized Taylor service personnel
should perform installation, maintenance, and
repairs on Taylor equipment.
•
Authorized service personnel should consult
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the industry
standards on lockout/tagout procedures before
beginning any installation or repairs.
•
Authorized service personnel must ensure that
the proper protective equipment (PPE) is
available and worn when required during
installation and service.
•
Authorized service personnel must remove all
metal jewelry, rings, and watches before work-
ing on electrical equipment.
DANGER! The main power supply(s) to the
machine must be disconnected prior to performing any
installation, maintenance, or repairs. Failure to follow this
instruction may result in personal injury or death from
electrical shock or hazardous moving parts as well as
poor performance or damage to the machine.
Note: All repairs must be performed by a Taylor service
technician.
WARNING! This machine has many sharp
edges that can cause severe injuries.
Site Preparation
Review the area where the unit will be installed before
uncrating the unit. Make sure that all possible hazards to
the user and the equipment have been addressed.
!
WARNING! Only install this machine in a
location where its use and maintenance is restricted to
trained personnel. Failure to comply may result in
personal injury.
For Indoor Use Only: This unit is designed to operate
indoors under normal ambient temperatures of
70°F to 75°F (21°C to 24C). The freezer has
successfully performed in high ambient temperatures of
104°F (40°C) at reduced capacities.
CAUTION! This machine must be installed on
a level surface to avoid the hazard of tipping. Extreme
care should be taken in moving this equipment for any
reason. Two or more persons are required to safely move
this machine. Failure to comply may result in personal
injury or equipment damage.
Uncrate the machine and inspect it for damage. Report
any damage to your Taylor distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.
Air-Cooled Units
Do not obstruct air intake and discharge openings.
Model C152 requires 4 in. (102 mm) of space on both
sides, and no space at the rear. Model C161 requires 6
in. (152 mm) of space on both sides, and no space at the
TO THE INSTALLER
085592-M
To the Installer
1
rear. If unit has legs, install the skirt provided on the right
side of the unit. Minimum air clearances must be met to
ensure adequate air flow for optimum performance.
Water Connections
Water-Cooled Units Only: An adequate cold water
supply must be provided with a hand shutoff valve. On
the underside rear of the base pan, two 3/8 in. I.P.S.
water connections for inlet and outlet have been provided
for easy hookup. Water lines connected to the machine
should have 1/2 in. inside diameters. (Flexible lines are
recommended, if local codes permit.) Depending on local
water conditions, it may be advisable to install a water
strainer to prevent foreign substances from clogging the
automatic water valve. There will be only one water-in
and one water-out connection. Do not install a hand
shutoff valve on the water-out line! Water should always
flow in this order: first, through the automatic water valve;
second, through the condenser; and third, through the
outlet fitting to an open trap drain.
!
CAUTION! A backflow prevention device is
required on the incoming water connection side on this
machine. Please refer to the applicable national state
and local codes for determining the proper configuration.
Failure to adhere to this safety precautions may result in
personal injury.
Electrical Connections
Each unit requires one power supply for each data label
on the unit. Check the data label(s) on the freezer for
branch circuit overcurrent protection or fuse, circuit
ampacity, and other electrical specifications. Refer to the
wiring diagram provided inside the electrical box for
proper power connections.
In the United States, this equipment is intended to be
installed in accordance with the National Electrical Code
(NEC) ANSI/NFPA 70-1987. The purpose of the NEC
code is the practical safeguarding of persons and
property from hazards arising from the use of electricity.
This code contains provisions considered necessary for
safety. Compliance therewith and proper maintenance
will result in an installation essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
IMPORTANT! An equipotential grounding lug is
provided with this machine. Some countries require the
grounding lug be properly attached to the rear of the
frame by the authorized installer. The installation location
is marked by the equipotential bonding symbol (5021 of
IEC 60417-1) on both the removable panel and the
machine's frame.
IMPORTANT!
•
Stationary appliances which are not equipped
with a power cord and a plug or another device
to disconnect the appliance from the power
source must have an all-pole disconnecting
device with a contact gap of at least 0.125 in. (3
mm) installed in the external installation.
•
Appliances that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices to
protect against the leakage of current, such as a
GFI, installed by the authorized personnel to the
local codes.
•
Supply cords used with this machine shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
•
If the supply cord is damaged, it must be
replaced by an authorized Taylor service
technician in order to avoid a hazard.
FOLLOW YOUR LOCAL ELECTRICAL CODES.
TO THE INSTALLER
1-3
085592-M
To the Installer
1
Electrical Hookup Installation
(60 Cycle, 1 Ph, Supplied with Cord and Plug)
This freezer is supplied with a three-wire cord and
grounding plug for connection to a single-phase, 60-
cycle, branch circuit supply. This unit must be plugged
into a properly grounded receptacle. For example, the
cord and plug provided for 115/60/1 is 20 A; therefore,
the wall outlet must also be 20 A. Check the data label,
located on the side panel, for electrical specifications.
Permanent wiring may be employed if required by local
codes. Instructions for conversion to permanent wiring
are as follows:
•
Be sure the freezer is electrically disconnected.
•
Remove the appropriate panel and locate the
small electrical box at the base of the freezer.
•
Remove the factory-installed cord and strain
relief bushing.
•
Route incoming permanent wiring through 7/8
in. (22 mm) hole in base pan.
•
Connect two power supply leads. Attach ground
(earth) wire to the grounding lug inside the
electrical box.
•
Be sure the unit is properly grounded before
applying power.
Beater Rotation
NOTICE! Beater rotation must be clockwise as
viewed looking into the freezing cylinder.
Refrigerant
CAUTION! In consideration of our environment,
Taylor uses only earth-friendly HFC refrigerants. The
HFC refrigerant used in this unit is R404A. This
refrigerant is generally considered nontoxic and
nonflammable, with an ozone depleting potential (ODP)
of zero (0). However, any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with liquid.
Filling the cylinder to approximately 80% will allow for
normal expansion.
!
CAUTION! Use only R404A refrigerant that
conforms to the AHRI standard 700 specification. The
use of any other refrigerant may expose users and
operators to unexpected safety hazards.
WARNING! Refrigerant liquid sprayed onto the
skin may cause serious damage to tissue. Keep eyes
and skin protected. If refrigerant burns should occur,
flush immediately with cold water. If burns are severe,
apply ice packs and contact a physician immediately.
NOTICE! Taylor reminds technicians to be
aware of and in compliance with local government laws
regarding refrigerant recovery, recycling, and reclaiming
systems. For information regarding applicable local laws,
please contact your local authorized Taylor distributor.
!
IMPORTANT! R404A refrigerant used in
conjunction with polyolester oils are extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
To the Operator
2
To the Operator
Operator Information
This soft serve freezer has been carefully engineered
and manufactured to give you dependable operation.
This machine, when properly operated and cared for, will
produce a consistent quality product. Like all mechanical
products, it will require cleaning and maintenance. A
minimum amount of care and attention is necessary if the
operating procedures outlined in this manual are followed
closely.
The Taylor soft serve models covered in this manual are
C152 and C161.
IMPORTANT! This manual should be read
before operating or performing any maintenance on the
machine.
Your Taylor machine will NOT compensate for and/or
correct any errors made during the setup or filling
operations. Thus, the initial assembly, setup, and priming
procedures are of extreme importance. It is strongly
recommended that all personnel responsible for the
machine’s operation, including assembly and
disassembly, go through these procedures together in
order to be properly trained and to make sure that all
personnel understand their role in using and maintaining
the machine.
In the event you should require technical assistance,
please contact your local authorized Taylor distributor.
Note: Your Taylor warranty is valid only if the parts are
authorized Taylor parts purchased from the local
authorized Taylor distributor, and only if all required
service work is provided by a Taylor service technician.
Taylor reserves the right to deny warranty claims on units
or parts if unapproved parts or incorrect refrigerant were
installed in the unit, system modifications were performed
beyond factory recommendations, or it is determined that
the failure was caused by abuse, misuse, neglect, or
failure to follow all operating instructions. For full details
of your Taylor warranty, please see "Limited Warranty on
Equipment" on page
10-1 and "Limited Warranty on
Parts" on page
11-1.
IMPORTANT! If the crossed-out, wheeled-bin
symbol is affixed to this machine, it signifies that this
machine is compliant with the EU Directives as well as
other similar end-of-life legislation in effect after August
13, 2005. Therefore, it must be collected separately after
its use is completed and cannot be disposed as unsorted
municipal waste.
The user is responsible for returning the machine to the
appropriate collection facility, as specified by your local
code.
For additional information regarding applicable local
disposal laws, please contact the municipal waste facility
and/or local authorized Taylor distributor.
Compressor Warranty Disclaimer
The refrigeration compressor(s) on this unit are
warranted for the term stated in the Limited Warranty
section in this manual. However, due to the Montreal
Protocol and the U.S. Clean Air Act Amendments of
1990, many new refrigerants are being tested and
developed, thus seeking their way into the service
industry. Some of these new refrigerants are being
advertised as drop-in replacements for numerous
applications. It should be noted that in the event of
ordinary service to this unit's refrigeration system, only
the refrigerant specified on the affixed data label
should be used. The unauthorized use of alternate
refrigerants will void your Taylor compressor warranty. It
is the unit owner's responsibility to make this fact known
to any technician he employs.
It should also be noted that Taylor does not warrant the
refrigerant used in its equipment. For example, if the
refrigerant is lost during the course of ordinary service to
this machine, Taylor has no obligation to either supply or
TO THE OPERATOR
085592-M
To the Operator
2
provide its replacement either at billable or non-billable
terms. Taylor does have the obligation to recommend a
suitable replacement if the original refrigerant is banned,
obsoleted, or no longer available during the five year
warranty of the compressor.
The Taylor Company will continue to monitor the industry
and test new alternates as they are being developed.
Should a new alternate prove through our testing that it
would be accepted as a drop-in replacement, the above
disclaimer would become null and void. To find the
current status of an alternate refrigerant as it relates to
your compressor warranty, call the local Taylor distributor
or the Taylor factory. Be prepared to provide the model/
serial number of the unit in question.
We at the Taylor Company are concerned about the
safety of the operator when he or she comes into contact
with the freezer and its parts. Taylor has gone to extreme
efforts to design and manufacture built-in safety features
to protect both you and the service technician. As an
example, warning labels have been attached to the
freezer to further point out safety precautions to the
operator.
!
DANGER! Failure to adhere to the following
safety precautions may result in severe personal injury or
death. Failure to comply with these warnings may also
damage the unit and/or its components. Such damage
may result in component replacement and service repair
expenses.
To Operate Safely
NOTICE! DO NOT operate the unit without
reading this entire manual first. Failure to follow all of
these operating instructions may result in damage to the
unit, poor performance, health hazards, or personal
injury.
WARNING! Avoid injury.
•
DO NOT allow untrained personnel to operate
this unit.
•
DO NOT operate the unit unless all service
panels and access doors are restrained with
screws.
•
DO NOT remove any internal operating parts
(including, but not limited to, freezer door,
beater, or scraper blades), unless all control
switches are in the OFF position.
Failure to follow these instructions may result in severe
personal injury, especially to fingers or hands, from
hazardous moving parts.
WARNING! This unit has many sharp edges
that can cause severe injuries.
!
•
DO NOT put objects or fingers in the door
spout. This may contaminate the product and
cause severe personal injury from blade
contact.
•
USE EXTREME CAUTION when removing the
beater assembly. The scraper blades are very
sharp.
IMPORTANT! Access to the service area of the
unit is restricted to persons having knowledge and
practical experience with the appliance, in particular as
far as safety and hygiene are concerned.
CAUTION! This machine must be placed on a
level surface. Extreme care should be taken when
moving for any reason. Two or more persons are
required to safely move this machine. Failure to comply
may result in personal injury or damage to the machine.
WARNING! Avoid injury.
•
DO NOT operate this machine unless it is
properly grounded.
•
DO NOT operate this machine with larger fuses
than specified on the unit's data label.
•
All repairs should be performed by an
authorized Taylor service technician.
•
Cord Connected Units: Only Taylor authorized
service technicians may install a plug on this
unit.
•
The main power supplied to the machine must
be disconnected prior to performing installation,
repairs, or maintenance.
Machines that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices to
protect against the leakage of current, such as a
GFI, installed by the authorized personnel to the
local codes.
•
Stationary machines which are not equipped
with a power cord and a plug or another device
to disconnect the appliance from the power
source must have an all-pole disconnecting
device with a contact gap of at least 0.125 in. (3
mm) installed in the external installation.
•
Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable not lighter
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
•
If the supply cord is damaged, it must be
replaced by an authorized Taylor service
technician in order to avoid a hazard.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
distributor for service.
!
CAUTION! This unit is equipped with a
refrigerated cabinet, designed to maintain product
temperature at or below 41°F (5°C). Any product being
added to this machine must be below 41°F (5°C). Failure
to follow this instruction may result in health hazards and
poor freezer performance.
DO NOT run the unit without product. Failure to follow
this instruction can result in damage to the unit.
DO NOT obstruct air intake and discharge openings: A
minimum of 4 in. (102 mm) on both sides, and 0 in the
rear is required for Model C152. A minimum of 6 in. (152
mm) on both sides, and 0 in the rear is required for Model
C161. If unit has legs, install the skirt provided on the
right side of the unit. Failure to follow this instruction may
cause poor freezer performance and damage to the
machine.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of 70°F to
75°F (21°C to 24°C). The unit has successfully
performed in high ambient temperatures of up to 104°F
(40°C) at reduced capacities.
Noise Level: Airborne noise emission does not exceed
78 dB(A) when measured at a distance of 39 in. (1.0 m)
from the surface of the unit and at a height of 62 in.
(1.6 m) from the floor.
Operator Parts Identification
4
Operator Parts Identification
Model C152
Figure
4-1
3
1
2
5
6
7
8
9
10
11
13
4
14 15
12
Item
Description
Part No.
1
Pan-Drip
085295
2
Panel-Left
086378
3
Cover A.-Hopper
X49633-SP
4
Tube-Feed
035819
5
Panel-Rear
086376
6
Panel-Right
086377
7
Gasket-Base Pan
086306
8
Tray-Drip
086312
Item
Description
Part No.
9
Shield-Splash
086379
10
Panel-Lower Front
086380
11
Panel-Front
086384
12
Trim-Corner-Rear
086375
13
Plate-Dec
X85775
14
Air Orifice
022465-100
15
O-Ring-3/8 OD X.070W
016137
OPERATOR PARTS IDENTIFICATION
085592-M
Operator Parts Identification
4
Model C161
Figure
4-2
3
1
2
4
5
6
7
8
9
10
11
12
13
14
Item
Description
Part No.
1
Pan-Drip
085295
2
Panel-Side-Left
085262
3
Cover A.-Hopper
085351
4
Tube-Feed
030797
5
Panel-Rear
085274
6
Panel A.-Side-Right
X69433
7
Gasket-Base Pan
055815-SP
Item
Description
Part No.
8
Tray-Drip 16-7/8L X 4-5/16
085699
9
Shield-Splash
085304
10
Panel-Lower Front
X85729-SER
11
Panel A.-Front
085678
12
Plate-Dec
X85775
13
Air Orifice
022465-100
14
O-Ring 3/8 OD X.070W
016137
OPERATOR PARTS IDENTIFICATION
4-3
085592-M
Operator Parts Identification
4
C152 Beater Door Assembly
Figure
4-3
1
2
3
4
5
8
10
12
13
9
11
7
6
Item
Description
Part No.
1
Valve-Draw
024763-SP1
2
O-Ring-7/8 OD X.103W
014402
3
Door A.-3SPT 1.5QT VALOX
X86373-SER
4
Pin A.-Pivot-Short
X38539
5
O-Ring-5/16 OD X.070W
016272
6
Handle-Draw
085615
7
Nut-Stud
034829-SP
Item
Description
Part No
8
Cap-Design 1.010"ID-6 PT.
014218
9
Bearing-Guide
014496
10
O-Ring-2-3/4 OD X .139W
019998
11
Bearing-Front
023262
12
Beater A.
X24689
13
Seal-U-Cup
080534
OPERATOR PARTS IDENTIFICATION
085592-M
Operator Parts Identification
4
C161 Beater Door Assembly
Figure
4-4
1
2
1
3
11
5
6
7
8
9
6
10
4
13
15
16
12
14
Item
Description
Part No.
1
Valve-Draw
024763-SP1
2
O-Ring-7/8 OD X.103W
014402
3
Seal-Draw Valve *Small H-Ring*
030930
4
Door A.-3SPT 1.5QT VALOX
X56906SER3
5
Pin A.-Pivot-Short
X38539
6
O-Ring-5/16 OD X.070W
016272
7
Handle-Draw
085615
8
Nut-Stud
056802-SP
Item
Description
Part No
9
Cap-Design 1.010"ID-6 PT.
014218
10
Pin A.-Pivot-Long
X38538
11
Valve-Draw-Center
031164-SP
12
Bearing-Guide
014496
13
O-Ring-2-3/4 OD X .139W
019998
14
Bearing-Front
023262
15
Beater A.-
X24689
16
Seal-U-Cup
080534
OPERATOR PARTS IDENTIFICATION
4-5
085592-M
Operator Parts Identification
4
C152 Accessories
Figure
4-5
*Not Shown: A sample container of sanitizer is sent with the
unit. For reorders, order Kay-5™
part no. 041082 (200 packs)
or Stera Sheen part no. 055492 (100 2 oz. packs).
1
2
3
4
5
6
7
8
9
Item
Description
Part No
1
Pail-6 qt.
023348
2
Brush-Rear BRG 1” D X 2” LG
013071
3
Brush-Double·Ended
013072
4
Brush-Draw·Valve·1” OD X 2” X
17”
013073
5
Brush-Mix·Pump·Body-3”X7”
White
023316
Item
Description
Part No.
6
Lubricant-Taylor 4 oz.
047518
7
Kit·A.-Tune Up
X25802
8
Leg (Optional)
024755
9
Skirt (Used with Legs Only)
086649
*
Sanitizer KAY-5 25 pkts
See Note
OPERATOR PARTS IDENTIFICATION
085592-M
Operator Parts Identification
4
C161 Accessories
Figure
4-6
*Not Shown - A sample container of sanitizer is sent with the
unit. For reorders, order Kay-5 part no. 041082 (200 packs) or
Stera Sheen part no. 055492 (100 2 oz. packs)
1
2
3
4
5
6
7
8
9
Item
Description
Part No
1
Pail-6·QT.
023348
2
Brush-Rear BRG 1” D X 2” LG
013071
3
Brush-Double·Ended
013072
4
Brush-Draw·Valve·1” OD X 2” X
17”
013073
5
Brush-Mix·Pump·Body-3”X7”
White
023316
Item
Description
Part No.
6
Lubricant-TAYLOR·4·OZ.
047518
7
Kit·A.-Tune·Up
X31167
8
Leg (Optional)
036397
9
Skirt (Used With Legs Only)
055508
*
Sanitizer KAY-5 25 PKTS
See Note
MIX REF Key
3
STANDBY Key
4
WASH Key
Item
Description
5
AUTO Key
6
Indicator Light Mix Low
7
Reset Button
8
Indicator Light Mix Out
To better communicate in the international arena, the
words on many of our operator switches and keys have
symbols to indicate their functions. Your Taylor
equipment is designed with these international symbols.
The following chart identifies the symbol definitions used
on the operator switches.
Power Switch
When placed in the ON position, the power switch allows
Softech™ control panel operation.
MIX REF Key
When the MIX REF key is pressed, the light comes on,
indicating the mix hopper refrigeration system is
operating. Mix refrigeration is controlled by the left side of
the freezer as viewed from the operator end. The Mix
refrigeration cannot be canceled unless the AUTO or
STANDBY modes are canceled first.
STANDBY Key
This unit is equipped with a standby feature. If product is
not dispensed for long periods of time (example: early
morning hours), the standby feature can be activated to
maintain the hopper and freezing cylinder product at safe
temperatures and prevent product breakdown. In the
standby mode, the wash and auto functions are
automatically canceled.
To use the standby feature, perform the following steps:
Note: Make sure your hands are clean and sanitized
before performing the following steps.
1.
Remove the air orifice and invert the mix feed tube so
that the end with the mix delivery hole is positioned at
the top. Install the end without the mix delivery hole
into the mix inlet hole in the bottom of the hopper.
This will prevent mix from entering the freezing
cylinder.
Figure
5-1 Feed Tube Position during Standby Operation
2.
Make sure there are at least 3 in. (76 mm) of mix in
the hopper and that the level of mix is not above the
mix delivery hole on the side of the feed tube.
Note: The level of mix must be below the mix delivery
hole on the side of the feed tube. Failure to follow this
instruction may result in lower product quality when
normal operation is resumed.
3.
Press the STANDBY key. The light will illuminate,
indicating that the unit is operating as a refrigerator
for product in the hopper and freezing cylinder.
4.
To remove the unit from the standby mode, press the
AUTO key. The STANDBY light will extinguish,
indicating the unit has resumed the normal operating
mode.
O
OFF
WASH
I
ON
AUTO
MIX
MIX LOW
STANDBY
MIX OUT
When the unit cycles off, place the feed tube in its
original position (mix delivery hole end down) and
install air orifice.
Figure
5-2 Feed Tube Position during Normal Operation
Important! The standby mode must not be used instead
of daily disassembly, cleaning, and sanitizing.
WASH Key
When the WASH key is pressed, the light comes on,
indicating beater motor operation. The standby or auto
mode must be canceled first to activate the wash mode.
AUTO Key
When the AUTO key is pressed, the light comes on,
indicating that the main refrigeration system has been
activated. In the auto mode, the wash or standby
functions are automatically canceled. The mix
refrigeration function is automatically locked in to
maintain the temperature of the mix in the mix hopper.
Note: An indicating light and an audible tone will sound
whenever a mode of operation has been pressed. To
cancel any function, press the key again. The light and
mode of operation will shut off.
Indicator Light—MIX LOW
Located on the front of the machine is a mix level
indicating light. When the light is flashing, it indicates that
the mix hopper has a low supply of mix and should be
refilled as soon as possible. Always maintain at least 3 in.
(76 mm) of mix in the hopper. If you neglect to add mix, a
freeze-up may occur. This will cause eventual damage to
the beater, blades, drive shaft, and freezer door.
Indicator Light—MIX OUT
When the Mix Out symbol is illuminated, the mix hopper
has almost completely exhausted and has an insufficient
supply of mix to operate the freezer. At this time, the Auto
mode is locked out and the freezer will be placed in the
Standby mode. To initiate the refrigeration system, add
mix to the mix hopper and touch the Auto symbol. The
freezer will automatically begin operation.
Reset Button
The reset button is located on the side of the C152 unit
and on the front of the C161 unit. The reset protects the
beater motor from an overload condition. If an overload
occurs, the reset mechanism will trip. To properly reset
the freezer:
1.
Press the AUTO key to cancel the cycle.
2.
Turn the power switch to the OFF position.
3.
Wait two or three minutes and then press the reset
button firmly.
CAUTION! DO NOT use metal objects to press
the reset button. Failure to follow this instruction may
result in electrocution.
4.
Turn the power switch to the ON position.
5.
Press the WASH key and observe the freezer's
performance. If the beater motor is turning properly,
press the WASH key to cancel the cycle.
6.
Press the AUTO key on both sides of the unit to
resume normal operation. If the freezer shuts down
again, contact a Taylor service technician.
The feed tube maintains overrun and allows enough mix
to enter the freezing cylinder after a draw. One end of the
tube has a mix delivery hole on the side, and the other
end does not.
Figure
5-3
The feed tube serves two purposes.
•
Normal Operation: After priming the machine, the
end of the feed tube with the mix delivery hole is
placed in the mix inlet hole, and the air orifice is
installed. Every time the draw handle is raised, new
mix and air from the hopper will flow down into the
freezing cylinder. This will keep the freezing cylinder
properly loaded and will maintain overrun.
Figure
5-4 Feed Tube Position during Normal Operation
•
Standby Operation: During long “no sale” periods,
the air orifice is removed and the feed tube is
inverted. The end of the feed tube without the mix
delivery hole is placed in the mix inlet hole to prevent
mix from entering the freezing cylinder.
Figure
5-5 Feed Tube Position during Standby Operation
Note: Make sure the level of mix is below the mix
delivery hole in the side of the feed tube. Failure to follow
this instruction may result in lower product quality when
normal operation is resumed.
The Model C161 has been selected to illustrate the
pictured step-by-step operating procedures. The models
in this manual are similar. They have a 1.5 qt. (1.4 L)
capacity freezing cylinder. The mix flows by gravity from
the hopper to the freezing cylinder through a feed tube.
Model C152 is a counter model with a single spout door.
Model C161 is a counter model with three spout doors.
Two individual flavors are available from the end spouts
and an equal combination of both is dispensed through
the center spout to create a twist effect.
We begin our instructions at the point where we enter the
store in the morning and find the parts disassembled and
laid out to air dry from the previous night's cleaning.
These opening procedures will show you how to
assemble these parts into the machine, sanitize them,
and prime the machine with fresh mix in preparation to
serve your first portion.
Duplicate the procedures where they apply for the
second freezing cylinder.
Figure
6-1
If you are disassembling the machine for the first time or
need information to get to the starting point in our
instructions, turn to "Disassembly" on page
6-7, and start
there.
Assembly
Note: When lubricating parts, use an approved food
grade lubricant (example: Taylor Lube).
1.
Lubricate the groove on the beater drive shaft. With
the opening of the cup seal facing away from the hex
end, slide the seal into the groove. Apply an even
coat of lubricant to the seal and the shaft. Do not
lubricate the hex end of the beater drive shaft.
Figure
6-2
2.
Insert the beater assembly through the rear shell
bearing at the back of the freezing cylinder and
engage the hex end firmly into the female socket.
When properly seated, the beater will not protrude
beyond the front of the freezing cylinder.
Figure
6-3
3.
Repeat step
1 and step
2 for the other side of the
machine.
11457
11456
Place the large O-rings into the grooves on the back
of the machine door and lubricate.
Figure
6-4
5.
Slide the front bearings over the baffle rods so that
the flanged edge is against the door. Place the white
plastic guide bearings on the end of the baffle rods.
Do not lubricate the front bearings or the guide
bearings.
Figure
6-5
6.
Slide the slotted portion of the handscrews into the
slots in the freezer door.
7.
With both hands, hold the sides of the freezer door
and insert the baffle rods into the center of the beater
assemblies. The white guide bearings must fit
securely in the holes of the drive shafts.
8.
Finger-tighten the handscrews, making sure they are
tightened equally and that the door is snug. Do not
overtighten the handscrews.
Figure
6-6
Important! Handscrew and door damage can result if the
handscrews are overtightened or if one handscrew is
tightened more than the other.
9.
(For Model C161 Only) Install the valve seal into the
grooves on the center draw valve and lubricate. This
special seal will prevent the mix in one freezing
cylinder from traveling into the second cylinder.
Figure
6-7
10335
10336
11070C
10. Slide the two O-rings into the grooves on the
remaining draw valves and lubricate.
Figure
6-8
11. Lubricate the inside of the freezer door spouts from
the bottom. Insert the draw valves into the freezer
door from the bottom until the slot in the draw valves
comes into view.
Figure
6-9
12. Slide the O-ring onto each pivot pin and lubricate.
Figure
6-10
13. Slide the tip of the draw handle into the slot of the
draw valve, starting from the right. Slide the short
pivot pin through the far right draw handle. Slide the
long pivot pin through the far left and middle draw
handles.
Figure
6-11
11070
10131a
14. Snap the design caps over the bottom of the freezer
door spouts.
Figure
6-12
15. Install the O-ring onto the groove of the air orifice. Do
not lubricate the O-ring.
Figure
6-13
Note: Make sure the hole in the orifice is clean and not
clogged. If the hole in the air orifice is clogged, use soap
and hot water to clear. Do not enlarge the hole in the air
orifice.
16. Install the air orifice to the end of the feed tube
without the hole in the side.
Figure
6-14
17. Lay the feed tube with air orifice in the bottom of the
mix hopper.
18. Lay the feed tubes in the bottom of the mix hoppers.
19. Install the front drip tray and splash shield under the
freezer door.
Figure
6-15
20. Install the drip pan.
Figure
6-16
Sanitizing
1.
Prepare an approved 100 PPM sanitizing solution
(examples: 2.5 gal. [9.5 L] of Kay-5®or 2 gal. [7.6 L]
of Stera-Sheen®). Use warm water and follow the
manufacturer's specifications.
2.
Pour 1 gal. (3.8 L) of sanitizing solution into the
hopper and allow it to flow into the freezing cylinder.
Figure
6-17
3.
While the solution is flowing into the freezing cylinder,
brush clean the mix hopper, the mix inlet hole, and
the feed tube.
Figure
6-18
Figure
6-19
4.
Place the power switch in the ON position.
Figure
6-20
12029
12235
12019
13093
131559
Press the WASH key to cause the sanitizing solution
in the freezing cylinder to be agitated. Allow it to
agitate for five minutes.
Figure
6-21
6.
Place an empty pail beneath the door spouts.
Momentarily open the center draw valve to sanitize
the center door spout. Open the remaining draw
valves to remove all of the sanitizing solution. When
the sanitizer stops flowing from the door spouts,
close the draw valves. Press the WASH key to
cancel the wash mode.
7.
With sanitized hands, stand the feed tube with air
orifice in the corner of the mix hopper.
Figure
6-22
8.
Repeat step
1 through step
7 for the other side of
the machine.
Priming
Prime the machine as close as possible to the time of first
product draw.
1.
With a pail beneath the door spouts, open the draw
valves. Fill the mix hopper with fresh mix and allow it
to flow into the freezing cylinder. This will force out
any remaining sanitizing solution. When mix is
flowing full strength from the door spouts, close the
draw valves.
Note: Use only fresh mix when priming the machine.
2.
When the mix has stopped bubbling down into the
freezing cylinder, install the feed tube and air orifice
in the mix inlet hole.
Figure
6-23
3.
Press the AUTO key. When the unit cycles off, the
product will be ready to serve.
Figure
6-24
13054w
131558
300113
30039_A
13054a
131560
(For Model C161) Repeat step
1 through step
3 for
the other side of the machine.
5.
Place the mix hopper cover in position.
Closing Procedure
To disassemble these units, the following items will be
needed:
•
Two cleaning pails
•
Sanitized stainless steel rerun can with lid
•
Necessary brushes (provided with machine)
•
Cleaner
•
Single-service towels
Draining Product from the Freezing
Cylinder
1.
Press the AUTO key to cancel operation. Press the
MIX REF key to cancel hopper refrigeration. These
operations should be canceled as far ahead of
cleaning time as possible to allow frozen product to
soften for easier cleaning.
Remove the mix hopper cover, and feed tube from
the machine. Take them to the sink for cleaning.
2.
If local health codes permit the use of rerun, place a
sanitized NSF-approved stainless steel rerun
container beneath the door spouts. Press the WASH
key and open the draw valves. When all the product
stops flowing from the door spouts, close the draw
valves and press the WASH key to cancel the wash
mode. Place the sanitized lid on the rerun container
and place it in the walk-in cooler.
Note: If local health codes do not permit the use of
rerun, the product must be discarded. Follow the
instructions in the previous step, except drain the product
into a pail and properly discard the mix.
!
ALWAYS FOLLOW LOCAL HEALTH CODES.
3.
Repeat step
1 through step
2 for the other side of
the machine.
Rinsing
1.
Pour 1 gal. (3.8 L) of cool, clean water into the mix
hopper. With the brushes provided, scrub the mix
hopper and the mix inlet hole.
2.
With a pail beneath the door spouts, press the WASH
key and open the draw valves.
3.
Drain all the rinse water from the freezing cylinder.
When the rinse water stops flowing from the door
spout, close the draw valves and press the WASH
key to cancel.
Repeat this procedure until the rinse water being
drawn from the freezing cylinder is clear.
4.
Repeat step
1 through step
3 for the other side of the
machine.
Cleaning
1.
Prepare an approved 100 PPM cleaning solution
(examples: 2.5 gal. [9.5 L] of Kay-5®or 2 gal. [7.6 L]
of Stera-Sheen®). Use warm water and follow the
manufacturer's specifications.
2.
Pour 1 gal. (3.8 L) of cleaning solution into the mix
hopper and allow it to flow into the freezing cylinder.
3.
While the solution is flowing into the freezing cylinder,
brush clean the mix hopper, the mix inlet hole, and
the mix level probe.
4.
Press the WASH key to cause the cleaning solution
in the freezing cylinder to agitate.
5.
Place an empty pail beneath the door spouts and
raise the draw valve. Draw off all the cleaning
solution. When the solution stops flowing from the
door spouts, close the draw valves. Press the WASH
key to cancel.
6.
Repeat step
1 through step
5 for the other side of the
machine.
Disassembly
1.
Remove the handscrews and the freezer door.
Remove the beater assemblies from the freezing
cylinders and take these parts to the sink for
cleaning.
2.
Remove the front drip tray, splash shield, and drip
pans from the machine. Take them to the sink for
cleaning.
Prepare a sink with an approved cleaning solution
(examples: Kay-5®or Stera-Sheen®). Use warm
water and follow the manufacturer's
specifications.
Important! Follow label directions. Too strong of a
solution can cause parts damage, while too weak of a
solution will not provide adequate cleaning. Make sure all
brushes provided with the machine are available for
brush cleaning.
2.
Remove the cup seals from the drive shafts of the
beater assemblies.
3.
From the freezer door, remove design caps, pivot
pins, draw handles, and draw valves. Remove all
O-rings.
Note: To remove O-rings, use a single-service towel to
grasp the O-ring. Apply pressure in an upward direction
until the O-ring pops out of its groove. With the other
hand, push the top of the O-ring forward; it will roll out of
the groove and can be easily removed. If more than one
O-ring needs to be removed, always remove the rear
O-ring first to allow the O-ring to slide over the forward
rings without falling into the open grooves.
4.
Remove the large O-rings, front bearings, and guide
bearings from the back of the freezer door.
5.
Return to the machine with a small amount of
cleaning solution. With the black bristle brush, brush
clean the rear shell bearings at the back of the
freezing cylinders.
Note: If the drip pan was filled with an excessive amount
of mix, the drive shaft O-ring of the beater assembly
should be replaced or properly lubricated.
6.
Thoroughly brush clean all disassembled parts in the
cleaning solution. Make sure all lubricant and mix film
is removed. Take particular care to brush clean the
draw valve cores in the freezer door. Place all the
cleaned parts on a clean, dry surface to air dry
overnight.
7.
Wipe clean all exterior surfaces of the machine.
ALWAYS FOLLOW LOCAL HEALTH CODES.
!
Section 7
7-1
085592-M
Operator Checklist
7
Operator Checklist
During Cleaning and Sanitizing
NOTICE! Cleaning and sanitizing schedules
are governed by federal, state, or local regulatory
agencies, and must be followed accordingly. If the unit
has a Standby mode, it must not be used in lieu of proper
cleaning and sanitizing procedures and frequencies set
forth by the ruling health authority. The following
checkpoints should be stressed during the cleaning and
sanitizing operations.
Troubleshooting Bacterial Count
Thoroughly clean and sanitize the machine
regularly, including complete disassembly and
brush cleaning.
Use all brushes supplied for thorough cleaning.
The brushes are specially designed to reach all
mix passageways.
Use the smaller, white bristle brush to clean the
mix inlet hole that extends from the mix hopper
down to the rear of the freezing cylinder.
Use the black bristle brush to thoroughly clean the
rear shell bearing located at the rear of the
freezing cylinder. Make sure to have a generous
amount of cleaning solution on the brush.
If local health codes permit the use of rerun,
make sure the mix rerun is stored in a sanitized,
covered stainless steel container and is used the
following day. Do not prime the machine with
rerun. When using rerun, skim the foam and
discard. Mix the rerun with fresh mix in a ratio of
50:50 during the day's operation.
On a designated day of the week, run the mix as
low as feasible and discard after closing. This will
break the rerun cycle and reduce the possibility of
high bacteria and coliform counts.
Properly prepare the cleaning and sanitizing
solutions. Read and follow label directions
carefully. Too strong of a solution may damage
the parts, and too weak of a solution will not
do an adequate job of cleaning or sanitizing.
The temperature of the mix in the mix hopper and
walk-in cooler should be below 40F (4.4C).
Regular Maintenance Checks
Check the rear shell bearing for signs of wear
(excessive mix leakage in rear drip pan) and
make sure it is properly cleaned.
Using a screwdriver and cloth towel, keep the rear
shell bearing and the female hex drive socket
clean and free of lubricant and mix deposits.
Dispose of O-rings or seals if they are worn, torn,
or fit too loosely, and replace with new ones.
Follow all lubricating procedures as outlined in
"Assembly" on page
6-1.
If your machine is air cooled, check the condenser
for an accumulation of dirt and lint. A dirty
condenser will reduce the efficiency and capacity
of the machine. Condensers should be cleaned
monthly with a soft brush. Never use
screwdrivers or other metal probes to clean
between the fins.
Note: For machines equipped with an air filter, it will be
necessary to vacuum clean the filters on a monthly
schedule.
If your machine is equipped with an auxiliary
refrigeration system, check the auxiliary
condenser for accumulation of dirt and lint. A dirty
condenser will reduce the refrigeration capacity of
the mix hopper. Condensers must be cleaned
monthly with a soft brush. Never use
screwdrivers or other metal probes to clean
between the fins. Failure to comply may result in
electrocution.
If your machine is water cooled, check the water
lines for kinks or leaks. Kinks can occur when the
machine is moved back and forth for cleaning or
maintenance purposes. Deteriorated or cracked
water lines should be replaced only by a Taylor
service technician.
Winter Storage
If the place of business is to be closed during the winter
months, it is important to protect the freezer by following
certain precautions, particularly if the building is subject
to freezing conditions.
Important! On water-cooled freezers, disconnect the
water supply. Relieve pressure on the spring in the water
valve. Use air pressure on the outlet side to blow out any
water remaining in the condenser. This is extremely
important. Failure to follow this procedure may cause
severe and costly damage to the refrigeration system.
Your local Taylor distributor can perform this service for
you.
•
Disconnect the freezer from the main power source
to prevent possible electrical damage.
•
Wrap detachable parts of the freezer, such as the
beater assembly and freezer door, and place them in
a protected dry place. Rubber trim parts and gaskets
can be protected by wrapping them with moisture-
proof paper.
•
All parts should be thoroughly cleaned of dried mix or
lubrication accumulations, which attract mice and
other vermin.
No product is being
dispensed.
a. The power switch is in the OFF
position.
a. Place the power switch in the AUTO
position.
5-2
b. The mix level is inadequate in the
mix hopper.
b. Fill the mix hopper with mix.
5-3
c. The beater motor overloaded.
c. Reset the freezer.
5-3
d. The unit is unplugged at the wall
receptacle.
d. Plug in the power cord.
1-1
e. The circuit breaker is tripped, or
the fuse is blown.
e. Place the circuit breaker in the ON
position or replace the fuse.
---
f. The freezer door is incorrectly
assembled.
f. See "Section
6: Operating
Procedures" for proper installation.
6-1
g. Product is being drawn off in
excess of the freezer’s capacity.
g. Stop drawing product and allow the
unit to recover.
---
2.
The machine will not
operate in the AUTO
mode.
a. The control is set too cold.
a. Contact service technician.
1-3
b. The refrigeration system is not
activated.
b. Momentarily raise the draw switch to
activate the refrigeration system.
5-3
c. The circuit breaker is tripped, or
the fuse is blown.
c. Place the circuit breaker in the ON
position or replace the fuse.
---
d. The beater motor overloaded,
causing a loss of power to the
power switch.
d. Reset the freezer.
5-3
3.
The product is too stiff.
a. The control is set too cold.
a. Contact service technician.
---
4.
The product is too soft.
a. The control is set too warm.
a. Contact service technician.
---
b. The air tube is not installed.
b. Install the air tube in the mix inlet hole
at the bottom of the mix hopper.
6-6
c. Out-drawing the freezer's capacity.
c. Two 4 oz. (113.4 g) servings in one
minute.
---
5.
The freezing cylinder
walls are scored.
a. Operating freezer without the front
bearing on the freezer door.
a. Install the front bearing on the freezer
door.
6-1
b. The gear unit or the direct drive is
out of alignment.
b. Contact service technician.
---
6.
Excessive leakage in
rear drip pan.
a. A worn or defective O-ring is on the
beater drive shaft.
a. Replace O-rings every 3 months.
9-1
b. The rear shell bearing is worn.
b. Contact service technician.
---
c. Incorrect lubricant was used.
c. Use food grade lubricant (example:
Taylor Lube).
6-1
d. Inadequate lubrication of beater
drive shaft.
d. Lubricate the beater drive shaft
properly.
6-1
The draw valve is
leaking.
a. Incorrect lubricant was used.
a. Use food grade lubricant (example:
Taylor Lube).
6-1
b. Worn or defective O-rings are on
the draw valve.
b. Replace O-rings every 3 months.
9-1
c. Inadequate lubrication of draw
valve.
c. Lubricate the draw valve properly.
6-1
8.
Product is not feeding
into the freezing
cylinder.
a. The mix level is inadequate in the
mix hopper.
a. Fill the mix hopper with mix.
5-3
b. The air orifice is not installed.
b. Install the air orifice in the air tube.
6-6
c. The air tube is installed incorrectly.
c. Install the air tube in the mix inlet
hole, using the end with the small
hole in the side.
6-6
d. The mix inlet hole is frozen.
d. Contact service technician.
---
9.
The unit goes out on
overload excessively.
a. There are too many appliances
plugged into the circuit.
a. A separate 20 A circuit is needed for
the freezer to operate properly.
---
b. An extension cord has been placed
between the power cord and the
wall receptacle.
b. If the extension cord is used, it must
match the power cord in size of circuit
ampacity.
---
10. Mix from one freezing
cylinder bleeds over to
the second cylinder.
a. The center draw valve seal is worn,
or improperly lubricated.
a. Lubricate properly and replace seal
every 3 months.
6-1, 9-1
Problem
Probable Cause
Remedy
Page
Ref.
Parts Replacement Schedule
9
Parts Replacement Schedule
Maintenance Intervals
Table 9-1
Part Description
Every 3 Months
Every 6 Months
Annually
C152 Qty.
C161 Qty.
Beater Drive Shaft Cup Seal
X
1
2
Freezer Door O-Ring
X
1
2
Freezer Door Front Bearing
X
1
2
Freezer Door Guide Bearing
X
1
2
Draw Valve O-Ring
X
2
4
Center Draw Valve Seal
X
N/A
1
Pivot Pin O-Ring
X
1
2
Black Bristle Brush, 1” x 2”
Inspect and replace
if necessary.
Minimum
1
1
Double Ended Brush
Inspect and replace
if necessary.
Minimum
1
1
White Bristle Brush, 1” x 2”
Inspect and replace
if necessary.
Minimum
1
1
White Bristle Brush, 3” x 7”
Inspect and replace
if necessary.
Minimum
1
1
Air Orifice O-Ring
X
Inspect and replace
if necessary.
Minimum
1
2
Limited Warranty on Equipment
10
Limited Warranty on Equipment
TAYLOR COMPANY LIMITED WARRANTY ON FREEZERS
Taylor Company is pleased to provide this limited warranty on new Taylor-branded freezer equipment (the “Product”)
available from Taylor to the market generally to the original purchaser only.
LIMITED WARRANTY
Taylor warrants the Product against failure due to defects in materials or workmanship under normal use and service
as follows. All warranty periods begin on the date of original Product installation. If a part fails due to defects during
the applicable warranty period, Taylor, through a Taylor-authorized Taylor distributor or service agency, will provide a
new or re-manufactured part, at Taylor's option, to replace the failed defective part at no charge for the part. Except
as otherwise stated herein, these are Taylor's exclusive obligations under this limited warranty for a Product failure.
This limited warranty is subject to all provisions, conditions, limitations, and exclusions listed below and on the
reverse (if any) of this document.
Table 10-1
LIMITED WARRANTY CONDITIONS
1.
If the date of original installation of the Product cannot be verified, then the limited warranty period begins ninety
(90) days from the date of Product manufacture (as indicated by the Product serial number). Proof of purchase may
be required at time of service.
2.
This limited warranty is valid only if the Product is installed and all required service work on the Product is
performed by a Taylor-authorized distributor or service agency, and only if genuine, new Taylor parts are used.
3.
Installation, use, care, and maintenance must be normal and in accordance with all instructions contained in the
Taylor Operator's Manual.
4.
Defective parts must be returned to the Taylor-authorized distributor or service agency for credit.
5.
The use of any refrigerant other than that specified on the Product's data label will void this limited warranty.
Product
Part
Limited Warranty Period
Soft Serve
Insulated Shell Assembly
Five (5) Years
Frozen Yogurt
Shakes
Refrigeration Compressor (except service
valve)
Five (5) Years
Smoothies
Beater Motors
Two (2) Years
Frozen Beverage
Beater Drive Gear
Two (2) Years
Batch Desserts
Printed Circuit Boards and Softech™
Controls beginning with Serial Number
H8024200
Two (2) Years
Parts Not Otherwise Listed in This Table
or Excluded Below
One (1) Years
LIMITED WARRANTY ON EQUIPMENT
085592-M
Limited Warranty on
10
LIMITED WARRANTY EXCEPTIONS
This limited warranty does not cover:
1.
Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing, or handling of
defective parts, replacement parts, or new Products.
2.
Normal maintenance, cleaning, and lubrication as outlined in the Taylor Operator's Manual, including cleaning of
condensers.
3.
Replacement of wear items designated as Class 000 parts in the Taylor Operator's Manual.
4.
External hoses, electrical power supplies, and machine grounding.
5.
Parts not supplied or designated by Taylor, or damages resulting from their use.
6.
Return trips or waiting time required because a service technician is prevented from beginning warranty service
work promptly upon arrival.
7.
Failure, damage, or repairs due to faulty installation, misapplication, abuse, no or improper servicing, unauthorized
alteration, or improper operation or use as indicated in the Taylor Operator's Manual, including but not limited to the
failure to use proper assembly and cleaning techniques, tools, or approved cleaning supplies.
8.
Failure, damage, or repairs due to theft, vandalism, wind, rain, flood, high water, water, lightning, earthquake, or
any other natural disaster, fire, corrosive environments, insect or rodent infestation, or other casualty, accident, or
condition beyond the reasonable control of Taylor; operation above or below the electrical or water supply
specification of the Product; components repaired or altered in any way so as to, in the judgment of the
Manufacturer, adversely affect performance, or normal wear or deterioration.
9.
Any Product purchased over the Internet.
10. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the inadequacy or
interruption of electrical service.
11. Electricity or fuel costs, or increases in electricity or fuel costs for any reason whatsoever.
12. Damages resulting from the use of any refrigerant other than that specified on the Product's data label.
13. Any cost to replace, refill, or dispose of refrigerant, including the cost of refrigerant.
14. Any special, indirect, or consequential property or commercial damage of any nature whatsoever. Some
jurisdictions do not allow the exclusion of incidental or consequential damages, so this limitation may not apply to
you.
This limited warranty gives you specific legal rights, and you may also have other rights that vary from jurisdiction to
jurisdiction.
LIMITED WARRANTY ON EQUIPMENT
10-3
085592-M
Limited Warranty on Equipment
10
LIMITATION OF WARRANTY
THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, AND/
OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER'S SOLE REMEDY
WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVE COMPONENTS
UNDER THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIAL OR INCIDENTAL
DAMAGES (INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS, PROPERTY DAMAGES,
OR SERVICE EXPENSES ARE EXPRESSLY EXCLUDED. THE EXPRESS WARRANTIES MADE IN THIS LIMITED
WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER
PERSON, WHATSOEVER.
LEGAL REMEDIES
The owner must notify Taylor in writing by certified or registered letter to the following address of any defect or
complaint with the Product, stating the defect or complaint and a specific request for repair, replacement, or other
correction of the Product under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.
Taylor Company
750 N. Blackhawk Blvd.
Rockton, IL 61072, U.S.A.
Limited Warranty on Parts
11
Limited Warranty on Parts
TAYLOR COMPANY LIMITED WARRANTY ON GENUINE TAYLOR PARTS
Taylor Company is pleased to provide this limited warranty on genuine, new Taylor replacement components and
parts (the “Parts”) available from Taylor to the market generally to the original purchaser only.
LIMITED WARRANTY
Taylor warrants the Parts against failure due to defect in materials or workmanship under normal use and service as
follows. All warranty periods begin on the date of original installation of the Part in the Taylor unit. If a Part fails due to
defects during the applicable warranty period, Taylor, through a Taylor-authorized distributor or service agency, will
provide a new or remanufactured Part, at Taylor's option, to replace the failed defective Part at no charge for the Part.
Except as otherwise stated herein, these are Taylor's exclusive obligations under this limited warranty for a Part
failure. This limited warranty is subject to all provisions, conditions, limitations, and exclusions listed below and on the
reverse (if any) of this document.
Table 11-1
LIMITED WARRANTY CONDITIONS
1.
If the date of original installation of the Part cannot be otherwise verified, proof of purchase may be required at time
of service.
2.
This limited warranty is valid only if the Part is installed and all required service work in connection with the Part is
performed by a Taylor-authorized distributor or service agency.
3.
The limited warranty applies only to Parts remaining in use by their original owner at their original installation
location in the unit of original installation.
4.
Installation, use, care, and maintenance must be normal and in accordance with all instructions contained in the
Taylor Operator's Manual.
5.
Defective Parts must be returned to the Taylor-authorized distributor or service agency for credit.
6.
This warranty is not intended to shorten the length of any warranty coverage provided pursuant to a separate
Taylor limited warranty on freezer or grill equipment.
7.
The use of any refrigerant other than that specified for the unit in which the Part is installed will void this limited
warranty.
Part's Warranty Class Code or Part
Limited Warranty Period
Class 103 Parts¹
Three (3) Months
Class 212 Parts²
Twelve (12) Months
Class 512 Parts
Twelve (12) Months
Class 000 Parts
No Warranty
Taylor Part #072454 (Motor-24VDC *C832/C842*)
Four (4) Years
1, 2 Except that Taylor Part #032129SER2 (Compressor-Air-230V SERV) and Taylor Part #075506SER1
(Compressor-Air-115V 60HZ) shall have a limited warranty period of twelve (12) months when used in Taylor freezer
equipment and a limited warranty period of two (2) years when used in Taylor grill equipment.
LIMITED WARRANTY ON PARTS
085592-M
Limited Warranty on Parts
11
LIMITED WARRANTY EXCEPTIONS
This limited warranty does not cover:
1.
Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing, or handling of
defective Parts, replacement Parts, or new Parts.
2.
Normal maintenance, cleaning, and lubrication as outlined in the Taylor Operator's Manual, including cleaning of
condensers or carbon and grease buildup.
3.
Required service, whether cleaning or general repairs, to return the cooking surface assemblies, including the
upper platen and lower plate, to an operational condition to achieve proper cooking or allow proper assembly of
release sheets and clips as a result of grease buildup on the cooking surfaces, including but not limited to the
platen and plate, sides of the shroud, or top of the shroud.
4.
Replacement of cooking surfaces, including the upper platen and lower plate, due to pitting or corrosion (or in the
case of the upper platen, due to loss of plating) as a result of damage due to the impact of spatulas or other small
wares used during the cooking process or as a result of the use of cleaners, cleaning materials, or cleaning
processes not approved for use by Taylor.
5.
Replacement of wear items designated as Class 000 Parts in the Taylor Operator's Manual, as well as any release
sheets and clips for the Product's upper platen assembly.
6.
External hoses, electrical power supplies, and machine grounding.
7.
Parts not supplied or designated by Taylor, or damages resulting from their use.
8.
Return trips or waiting time required because a service technician is prevented from beginning warranty service
work promptly upon arrival.
9.
Failure, damage, or repairs due to faulty installation, misapplication, abuse, no or improper servicing, unauthorized
alteration or improper operation or use as indicated in the Taylor Operator's Manual, including but not limited to the
failure to use proper assembly and cleaning techniques, tools, or approved cleaning supplies.
10. Failure, damage or repairs due to theft, vandalism, wind, rain, flood, high water, water, lightning, earthquake, or any
other natural disaster, fire, corrosive environments, insect or rodent infestation, or other casualty, accident or
condition beyond the reasonable control of Taylor; operation above or below the gas, electrical, or water supply
specification of the unit in which a part is installed; Parts or the units in which they are installed repaired or altered
in any way so as to, in the judgment of Taylor, adversely affect performance, or normal wear or deterioration.
11. Any Part purchased over the Internet.
12. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the inadequacy or
interruption of electrical service.
13. Electricity, gas, or other fuel costs, or increases in electricity or fuel costs for any reason whatsoever.
14. Damages resulting from the use of any refrigerant other than that specified for the unit in which the Part is installed.
15. Any cost to replace, refill, or dispose of refrigerant, including the cost of refrigerant.
16. Any special, indirect, or consequential property or commercial damage of any nature whatsoever. Some
jurisdictions do not allow the exclusion of incidental or consequential damages, so this limitation may not apply to
you.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from jurisdiction to
jurisdiction.
LIMITED WARRANTY ON PARTS
11-3
085592-M
Limited Warranty on Parts
11
LIMITATION OF WARRANTY
THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, AND/
OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER'S SOLE REMEDY
WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS UNDER
THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIAL OR INCIDENTAL DAMAGES,
(INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS, PROPERTY DAMAGES OR
SERVICE EXPENSES ARE EXPRESSLY EXCLUDED. THE EXPRESS WARRANTIES MADE IN THIS LIMITED
WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER
PERSON, WHATSOEVER.
LEGAL REMEDIES
The owner must notify Taylor in writing by certified or registered letter to the following address of any defect or
complaint with the Part, stating the defect or complaint and a specific request for repair, replacement, or other
correction of the Part under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.
Taylor Company
750 N. Blackhawk Blvd.
Rockton, IL 61072, U.S.A.