Taylor C152 Operator's Manual

Text of the manual

1/23/2017 (Original Publication)

(Updated 6/28/18) OPERATOR’S MANUAL Model C152 & C161 Soft Serve Freezer Original Service Instructions 085592-M

Complete this page for quick reference when service is required:

Taylor Distributor: __________________________________________________________ Address:_________________________________________________________________ Phone: __________________________________________________________________ Service: _________________________________________________________________ Parts: ___________________________________________________________________ Date of Installation: ________________________________________________________ Information found on the data label: Model Number: ___________________________________________________________ Serial Number: ____________________________________________________________ Electrical Specs: Voltage__________________ Cycle__________ Phase__________________________________ Maximum Fuse Size: ______________________________________________________ A Minimum Wire Ampacity: ___________________________________________________ A Note: Continuing research results in steady improvements; therefore, information in this manual is subject to change without notice. Note: Only instructions originating from the factory or its authorized translation representative(s) are considered to be the original set of instructions. © 2017 Taylor Company 085592-M Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this work may be a violation of copyright law of the United States of America and other countries, could result in the awarding of statutory damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties. All rights reserved. Taylor Company 750 N. Blackhawk Blvd. Rockton, IL 61072

Table of Contents

085592-M i Section 1: To the Installer Installer Safety ...................................................................................................1-1 Site Preparation .................................................................................................1-1 Air-Cooled Units.................................................................................................1-1 Water Connections.............................................................................................1-2 Electrical Connections........................................................................................1-2 Electrical Hookup Installation.............................................................................1-3 Beater Rotation ..................................................................................................1-3 Refrigerant .........................................................................................................1-3 Section 2: To the Operator Operator Information..........................................................................................2-1 Section 3: Safety Installer Information............................................................................................3-1 Section 4: Operator Parts Identification Model C152........................................................................................................4-1 Model C161........................................................................................................4-2 C152 Beater Door Assembly..............................................................................4-3 C161 Beater Door Assembly..............................................................................4-4 C152 Accessories ..............................................................................................4-5 C161 Accessories ..............................................................................................4-6 Section 5: User Interface C152...................................................................................................................5-1 C161...................................................................................................................5-1 Symbol Definitions .............................................................................................5-2 Power Switch .....................................................................................................5-2 MIX REF Key .....................................................................................................5-2 STANDBY Key...................................................................................................5-2 WASH Key .........................................................................................................5-3 AUTO Key..........................................................................................................5-3 Indicator Light—MIX LOW .................................................................................5-3 Indicator Light—MIX OUT..................................................................................5-3 Reset Button ......................................................................................................5-3 Feed Tube..........................................................................................................5-4

Section 6: Operating Procedures

Assembly............................................................................................................6-1 Sanitizing............................................................................................................6-5 Priming ...............................................................................................................6-6 Closing Procedure..............................................................................................6-7 Draining Product from the Freezing Cylinder .....................................................6-7 Rinsing ...............................................................................................................6-7 Cleaning .............................................................................................................6-7 Disassembly.......................................................................................................6-7 Brush Cleaning...................................................................................................6-8 Section 7: Operator Checklist During Cleaning and Sanitizing..........................................................................7-1 Troubleshooting Bacterial Count........................................................................7-1 Regular Maintenance Checks ............................................................................7-1 Winter Storage ...................................................................................................7-2 Section 8: Troubleshooting Guide Section 9: Parts Replacement Schedule Maintenance Intervals ........................................................................................9-1 Section 10: Limited Warranty on Equipment Section 11: Limited Warranty on Parts

To the Installer

1 To the Installer The following information has been included in the manual as safety and regulatory guidelines. For complete installation instructions, please see the Installation Checklist. ! Installer Safety IMPORTANT! In all areas of the world, equipment should be installed in accordance with existing local codes. Please contact your local authorities if you have any questions. Care should be taken to ensure that all basic safety practices are followed during the installation and servicing activities related to the installation and service of Taylor® equipment. • Only authorized Taylor service personnel should perform installation, maintenance, and repairs on Taylor equipment. • Authorized service personnel should consult OSHA Standard 29CFRI910.147 or the applicable code of the local area for the industry standards on lockout/tagout procedures before beginning any installation or repairs. • Authorized service personnel must ensure that the proper protective equipment (PPE) is available and worn when required during installation and service. • Authorized service personnel must remove all metal jewelry, rings, and watches before work- ing on electrical equipment. DANGER! The main power supply(s) to the machine must be disconnected prior to performing any installation, maintenance, or repairs. Failure to follow this instruction may result in personal injury or death from electrical shock or hazardous moving parts as well as poor performance or damage to the machine. Note: All repairs must be performed by a Taylor service technician. WARNING! This machine has many sharp edges that can cause severe injuries. Site Preparation Review the area where the unit will be installed before uncrating the unit. Make sure that all possible hazards to the user and the equipment have been addressed. ! WARNING! Only install this machine in a location where its use and maintenance is restricted to trained personnel. Failure to comply may result in personal injury. For Indoor Use Only: This unit is designed to operate indoors under normal ambient temperatures of 70°F to 75°F (21°C to 24C). The freezer has successfully performed in high ambient temperatures of 104°F (40°C) at reduced capacities. CAUTION! This machine must be installed on a level surface to avoid the hazard of tipping. Extreme care should be taken in moving this equipment for any reason. Two or more persons are required to safely move this machine. Failure to comply may result in personal injury or equipment damage. Uncrate the machine and inspect it for damage. Report any damage to your Taylor distributor. This piece of equipment is made in the USA and has USA sizes of hardware. All metric conversions are approximate and vary in size. Air-Cooled Units Do not obstruct air intake and discharge openings. Model C152 requires 4 in. (102 mm) of space on both sides, and no space at the rear. Model C161 requires 6 in. (152 mm) of space on both sides, and no space at the

TO THE INSTALLER

085592-M To the Installer 1 rear. If unit has legs, install the skirt provided on the right side of the unit. Minimum air clearances must be met to ensure adequate air flow for optimum performance. Water Connections Water-Cooled Units Only: An adequate cold water supply must be provided with a hand shutoff valve. On the underside rear of the base pan, two 3/8 in. I.P.S. water connections for inlet and outlet have been provided for easy hookup. Water lines connected to the machine should have 1/2 in. inside diameters. (Flexible lines are recommended, if local codes permit.) Depending on local water conditions, it may be advisable to install a water strainer to prevent foreign substances from clogging the automatic water valve. There will be only one water-in and one water-out connection. Do not install a hand shutoff valve on the water-out line! Water should always flow in this order: first, through the automatic water valve; second, through the condenser; and third, through the outlet fitting to an open trap drain. ! CAUTION! A backflow prevention device is required on the incoming water connection side on this machine. Please refer to the applicable national state and local codes for determining the proper configuration. Failure to adhere to this safety precautions may result in personal injury. Electrical Connections Each unit requires one power supply for each data label on the unit. Check the data label(s) on the freezer for branch circuit overcurrent protection or fuse, circuit ampacity, and other electrical specifications. Refer to the wiring diagram provided inside the electrical box for proper power connections. In the United States, this equipment is intended to be installed in accordance with the National Electrical Code (NEC) ANSI/NFPA 70-1987. The purpose of the NEC code is the practical safeguarding of persons and property from hazards arising from the use of electricity. This code contains provisions considered necessary for safety. Compliance therewith and proper maintenance will result in an installation essentially free from hazard! In all other areas of the world, equipment should be installed in accordance with the existing local codes. Please contact your local authorities. IMPORTANT! An equipotential grounding lug is provided with this machine. Some countries require the grounding lug be properly attached to the rear of the frame by the authorized installer. The installation location is marked by the equipotential bonding symbol (5021 of IEC 60417-1) on both the removable panel and the machine's frame. IMPORTANT! • Stationary appliances which are not equipped with a power cord and a plug or another device to disconnect the appliance from the power source must have an all-pole disconnecting device with a contact gap of at least 0.125 in. (3 mm) installed in the external installation. • Appliances that are permanently connected to fixed wiring and for which leakage currents may exceed 10 mA, particularly when disconnected or not used for long periods, or during initial installation, shall have protective devices to protect against the leakage of current, such as a GFI, installed by the authorized personnel to the local codes. • Supply cords used with this machine shall be oil-resistant, sheathed flexible cable not lighter than ordinary polychloroprene or other equivalent synthetic elastomer-sheathed cord (code designation 60245 IEC 57) installed with the proper cord anchorage to relieve conductors from strain, including twisting, at the terminals and protect the insulation of the conductors from abrasion. • If the supply cord is damaged, it must be replaced by an authorized Taylor service technician in order to avoid a hazard. FOLLOW YOUR LOCAL ELECTRICAL CODES.

TO THE INSTALLER

1-3 085592-M To the Installer 1 Electrical Hookup Installation (60 Cycle, 1 Ph, Supplied with Cord and Plug) This freezer is supplied with a three-wire cord and grounding plug for connection to a single-phase, 60- cycle, branch circuit supply. This unit must be plugged into a properly grounded receptacle. For example, the cord and plug provided for 115/60/1 is 20 A; therefore, the wall outlet must also be 20 A. Check the data label, located on the side panel, for electrical specifications. Permanent wiring may be employed if required by local codes. Instructions for conversion to permanent wiring are as follows: • Be sure the freezer is electrically disconnected. • Remove the appropriate panel and locate the small electrical box at the base of the freezer. • Remove the factory-installed cord and strain relief bushing. • Route incoming permanent wiring through 7/8 in. (22 mm) hole in base pan. • Connect two power supply leads. Attach ground (earth) wire to the grounding lug inside the electrical box. • Be sure the unit is properly grounded before applying power. Beater Rotation NOTICE! Beater rotation must be clockwise as viewed looking into the freezing cylinder. Refrigerant CAUTION! In consideration of our environment, Taylor uses only earth-friendly HFC refrigerants. The HFC refrigerant used in this unit is R404A. This refrigerant is generally considered nontoxic and nonflammable, with an ozone depleting potential (ODP) of zero (0). However, any gas under pressure is potentially hazardous and must be handled with caution. NEVER fill any refrigerant cylinder completely with liquid. Filling the cylinder to approximately 80% will allow for normal expansion. ! CAUTION! Use only R404A refrigerant that conforms to the AHRI standard 700 specification. The use of any other refrigerant may expose users and operators to unexpected safety hazards. WARNING! Refrigerant liquid sprayed onto the skin may cause serious damage to tissue. Keep eyes and skin protected. If refrigerant burns should occur, flush immediately with cold water. If burns are severe, apply ice packs and contact a physician immediately. NOTICE! Taylor reminds technicians to be aware of and in compliance with local government laws regarding refrigerant recovery, recycling, and reclaiming systems. For information regarding applicable local laws, please contact your local authorized Taylor distributor. ! IMPORTANT! R404A refrigerant used in conjunction with polyolester oils are extremely moisture absorbent. When opening a refrigeration system, the maximum time the system is open must not exceed 15 minutes. Cap all open tubing to prevent humid air or water from being absorbed by the oil.

To the Operator

2 To the Operator Operator Information This soft serve freezer has been carefully engineered and manufactured to give you dependable operation. This machine, when properly operated and cared for, will produce a consistent quality product. Like all mechanical products, it will require cleaning and maintenance. A minimum amount of care and attention is necessary if the operating procedures outlined in this manual are followed closely. The Taylor soft serve models covered in this manual are C152 and C161. IMPORTANT! This manual should be read before operating or performing any maintenance on the machine. Your Taylor machine will NOT compensate for and/or correct any errors made during the setup or filling operations. Thus, the initial assembly, setup, and priming procedures are of extreme importance. It is strongly recommended that all personnel responsible for the machine’s operation, including assembly and disassembly, go through these procedures together in order to be properly trained and to make sure that all personnel understand their role in using and maintaining the machine. In the event you should require technical assistance, please contact your local authorized Taylor distributor. Note: Your Taylor warranty is valid only if the parts are authorized Taylor parts purchased from the local authorized Taylor distributor, and only if all required service work is provided by a Taylor service technician. Taylor reserves the right to deny warranty claims on units or parts if unapproved parts or incorrect refrigerant were installed in the unit, system modifications were performed beyond factory recommendations, or it is determined that the failure was caused by abuse, misuse, neglect, or failure to follow all operating instructions. For full details of your Taylor warranty, please see "Limited Warranty on Equipment" on page 10-1 and "Limited Warranty on Parts" on page 11-1. IMPORTANT! If the crossed-out, wheeled-bin symbol is affixed to this machine, it signifies that this machine is compliant with the EU Directives as well as other similar end-of-life legislation in effect after August 13, 2005. Therefore, it must be collected separately after its use is completed and cannot be disposed as unsorted municipal waste. The user is responsible for returning the machine to the appropriate collection facility, as specified by your local code. For additional information regarding applicable local disposal laws, please contact the municipal waste facility and/or local authorized Taylor distributor. Compressor Warranty Disclaimer The refrigeration compressor(s) on this unit are warranted for the term stated in the Limited Warranty section in this manual. However, due to the Montreal Protocol and the U.S. Clean Air Act Amendments of 1990, many new refrigerants are being tested and developed, thus seeking their way into the service industry. Some of these new refrigerants are being advertised as drop-in replacements for numerous applications. It should be noted that in the event of ordinary service to this unit's refrigeration system, only the refrigerant specified on the affixed data label should be used. The unauthorized use of alternate refrigerants will void your Taylor compressor warranty. It is the unit owner's responsibility to make this fact known to any technician he employs. It should also be noted that Taylor does not warrant the refrigerant used in its equipment. For example, if the refrigerant is lost during the course of ordinary service to this machine, Taylor has no obligation to either supply or

TO THE OPERATOR

085592-M To the Operator 2 provide its replacement either at billable or non-billable terms. Taylor does have the obligation to recommend a suitable replacement if the original refrigerant is banned, obsoleted, or no longer available during the five year warranty of the compressor. The Taylor Company will continue to monitor the industry and test new alternates as they are being developed. Should a new alternate prove through our testing that it would be accepted as a drop-in replacement, the above disclaimer would become null and void. To find the current status of an alternate refrigerant as it relates to your compressor warranty, call the local Taylor distributor or the Taylor factory. Be prepared to provide the model/ serial number of the unit in question.

We at the Taylor Company are concerned about the

safety of the operator when he or she comes into contact with the freezer and its parts. Taylor has gone to extreme efforts to design and manufacture built-in safety features to protect both you and the service technician. As an example, warning labels have been attached to the freezer to further point out safety precautions to the operator. ! DANGER! Failure to adhere to the following safety precautions may result in severe personal injury or death. Failure to comply with these warnings may also damage the unit and/or its components. Such damage may result in component replacement and service repair expenses. To Operate Safely NOTICE! DO NOT operate the unit without reading this entire manual first. Failure to follow all of these operating instructions may result in damage to the unit, poor performance, health hazards, or personal injury. WARNING! Avoid injury. • DO NOT allow untrained personnel to operate this unit. • DO NOT operate the unit unless all service panels and access doors are restrained with screws. • DO NOT remove any internal operating parts (including, but not limited to, freezer door, beater, or scraper blades), unless all control switches are in the OFF position. Failure to follow these instructions may result in severe personal injury, especially to fingers or hands, from hazardous moving parts. WARNING! This unit has many sharp edges that can cause severe injuries. ! • DO NOT put objects or fingers in the door spout. This may contaminate the product and cause severe personal injury from blade contact. • USE EXTREME CAUTION when removing the beater assembly. The scraper blades are very sharp. IMPORTANT! Access to the service area of the unit is restricted to persons having knowledge and practical experience with the appliance, in particular as far as safety and hygiene are concerned. CAUTION! This machine must be placed on a level surface. Extreme care should be taken when moving for any reason. Two or more persons are required to safely move this machine. Failure to comply may result in personal injury or damage to the machine. WARNING! Avoid injury. • DO NOT operate this machine unless it is properly grounded. • DO NOT operate this machine with larger fuses than specified on the unit's data label. • All repairs should be performed by an authorized Taylor service technician. • Cord Connected Units: Only Taylor authorized service technicians may install a plug on this unit. • The main power supplied to the machine must be disconnected prior to performing installation, repairs, or maintenance.

Machines that are permanently connected to

fixed wiring and for which leakage currents may exceed 10 mA, particularly when disconnected or not used for long periods, or during initial installation, shall have protective devices to protect against the leakage of current, such as a GFI, installed by the authorized personnel to the local codes. • Stationary machines which are not equipped with a power cord and a plug or another device to disconnect the appliance from the power source must have an all-pole disconnecting device with a contact gap of at least 0.125 in. (3 mm) installed in the external installation. • Supply cords used with this unit shall be oil-resistant, sheathed flexible cable not lighter than ordinary polychloroprene or other equivalent synthetic elastomer-sheathed cord (code designation 60245 IEC 57) installed with the proper cord anchorage to relieve conductors from strain, including twisting, at the terminals and protect the insulation of the conductors from abrasion. • If the supply cord is damaged, it must be replaced by an authorized Taylor service technician in order to avoid a hazard. Failure to follow these instructions may result in electrocution. Contact your local authorized Taylor distributor for service. ! CAUTION! This unit is equipped with a refrigerated cabinet, designed to maintain product temperature at or below 41°F (5°C). Any product being added to this machine must be below 41°F (5°C). Failure to follow this instruction may result in health hazards and poor freezer performance. DO NOT run the unit without product. Failure to follow this instruction can result in damage to the unit. DO NOT obstruct air intake and discharge openings: A minimum of 4 in. (102 mm) on both sides, and 0 in the rear is required for Model C152. A minimum of 6 in. (152 mm) on both sides, and 0 in the rear is required for Model C161. If unit has legs, install the skirt provided on the right side of the unit. Failure to follow this instruction may cause poor freezer performance and damage to the machine. For Indoor Use Only: This unit is designed to operate indoors, under normal ambient temperatures of 70°F to 75°F (21°C to 24°C). The unit has successfully performed in high ambient temperatures of up to 104°F (40°C) at reduced capacities. Noise Level: Airborne noise emission does not exceed 78 dB(A) when measured at a distance of 39 in. (1.0 m) from the surface of the unit and at a height of 62 in. (1.6 m) from the floor.

Operator Parts Identification

4 Operator Parts Identification Model C152 Figure 4-1 3 1 2 5 6 7 8 9 10 11 13 4 14 15 12 Item Description Part No. 1 Pan-Drip 085295 2 Panel-Left 086378 3 Cover A.-Hopper X49633-SP 4 Tube-Feed 035819 5 Panel-Rear 086376 6 Panel-Right 086377 7 Gasket-Base Pan 086306 8 Tray-Drip 086312 Item Description Part No. 9 Shield-Splash 086379 10 Panel-Lower Front 086380 11 Panel-Front 086384 12 Trim-Corner-Rear 086375 13 Plate-Dec X85775 14 Air Orifice 022465-100 15 O-Ring-3/8 OD X.070W 016137

OPERATOR PARTS IDENTIFICATION

085592-M Operator Parts Identification 4 Model C161 Figure 4-2 3 1 2 4 5 6 7 8 9 10 11 12 13 14 Item Description Part No. 1 Pan-Drip 085295 2 Panel-Side-Left 085262 3 Cover A.-Hopper 085351 4 Tube-Feed 030797 5 Panel-Rear 085274 6 Panel A.-Side-Right X69433 7 Gasket-Base Pan 055815-SP Item Description Part No. 8 Tray-Drip 16-7/8L X 4-5/16 085699 9 Shield-Splash 085304 10 Panel-Lower Front X85729-SER 11 Panel A.-Front 085678 12 Plate-Dec X85775 13 Air Orifice 022465-100 14 O-Ring 3/8 OD X.070W 016137

OPERATOR PARTS IDENTIFICATION

4-3 085592-M Operator Parts Identification 4 C152 Beater Door Assembly Figure 4-3 1 2 3 4 5 8 10 12 13 9 11 7 6 Item Description Part No. 1 Valve-Draw 024763-SP1 2 O-Ring-7/8 OD X.103W 014402 3 Door A.-3SPT 1.5QT VALOX X86373-SER 4 Pin A.-Pivot-Short X38539 5 O-Ring-5/16 OD X.070W 016272 6 Handle-Draw 085615 7 Nut-Stud 034829-SP Item Description Part No 8 Cap-Design 1.010"ID-6 PT. 014218 9 Bearing-Guide 014496 10 O-Ring-2-3/4 OD X .139W 019998 11 Bearing-Front 023262 12 Beater A. X24689 13 Seal-U-Cup 080534

OPERATOR PARTS IDENTIFICATION

085592-M Operator Parts Identification 4 C161 Beater Door Assembly Figure 4-4 1 2 1 3 11 5 6 7 8 9 6 10 4 13 15 16 12 14 Item Description Part No. 1 Valve-Draw 024763-SP1 2 O-Ring-7/8 OD X.103W 014402 3 Seal-Draw Valve *Small H-Ring* 030930 4 Door A.-3SPT 1.5QT VALOX X56906SER3 5 Pin A.-Pivot-Short X38539 6 O-Ring-5/16 OD X.070W 016272 7 Handle-Draw 085615 8 Nut-Stud 056802-SP Item Description Part No 9 Cap-Design 1.010"ID-6 PT. 014218 10 Pin A.-Pivot-Long X38538 11 Valve-Draw-Center 031164-SP 12 Bearing-Guide 014496 13 O-Ring-2-3/4 OD X .139W 019998 14 Bearing-Front 023262 15 Beater A.- X24689 16 Seal-U-Cup 080534

OPERATOR PARTS IDENTIFICATION

4-5 085592-M Operator Parts Identification 4 C152 Accessories Figure 4-5 *Not Shown: A sample container of sanitizer is sent with the unit. For reorders, order Kay-5™ part no. 041082 (200 packs) or Stera Sheen part no. 055492 (100 2 oz. packs). 1 2 3 4 5 6 7 8 9 Item Description Part No 1 Pail-6 qt. 023348 2 Brush-Rear BRG 1” D X 2” LG 013071 3 Brush-Double·Ended 013072 4 Brush-Draw·Valve·1” OD X 2” X 17” 013073 5 Brush-Mix·Pump·Body-3”X7” White 023316 Item Description Part No. 6 Lubricant-Taylor 4 oz. 047518 7 Kit·A.-Tune Up X25802 8 Leg (Optional) 024755 9 Skirt (Used with Legs Only) 086649 * Sanitizer KAY-5 25 pkts See Note

OPERATOR PARTS IDENTIFICATION

085592-M Operator Parts Identification 4 C161 Accessories Figure 4-6 *Not Shown - A sample container of sanitizer is sent with the unit. For reorders, order Kay-5 part no. 041082 (200 packs) or Stera Sheen part no. 055492 (100 2 oz. packs) 1 2 3 4 5 6 7 8 9 Item Description Part No 1 Pail-6·QT. 023348 2 Brush-Rear BRG 1” D X 2” LG 013071 3 Brush-Double·Ended 013072 4 Brush-Draw·Valve·1” OD X 2” X 17” 013073 5 Brush-Mix·Pump·Body-3”X7” White 023316 Item Description Part No. 6 Lubricant-TAYLOR·4·OZ. 047518 7 Kit·A.-Tune·Up X31167 8 Leg (Optional) 036397 9 Skirt (Used With Legs Only) 055508 * Sanitizer KAY-5 25 PKTS See Note

MIX REF Key

3 STANDBY Key 4 WASH Key Item Description 5 AUTO Key 6 Indicator Light Mix Low 7 Reset Button 8 Indicator Light Mix Out

To better communicate in the international arena, the

words on many of our operator switches and keys have symbols to indicate their functions. Your Taylor equipment is designed with these international symbols. The following chart identifies the symbol definitions used on the operator switches. Power Switch When placed in the ON position, the power switch allows Softech™ control panel operation. MIX REF Key When the MIX REF key is pressed, the light comes on, indicating the mix hopper refrigeration system is operating. Mix refrigeration is controlled by the left side of the freezer as viewed from the operator end. The Mix refrigeration cannot be canceled unless the AUTO or STANDBY modes are canceled first. STANDBY Key This unit is equipped with a standby feature. If product is not dispensed for long periods of time (example: early morning hours), the standby feature can be activated to maintain the hopper and freezing cylinder product at safe temperatures and prevent product breakdown. In the standby mode, the wash and auto functions are automatically canceled. To use the standby feature, perform the following steps: Note: Make sure your hands are clean and sanitized before performing the following steps. 1. Remove the air orifice and invert the mix feed tube so that the end with the mix delivery hole is positioned at the top. Install the end without the mix delivery hole into the mix inlet hole in the bottom of the hopper. This will prevent mix from entering the freezing cylinder. Figure 5-1 Feed Tube Position during Standby Operation 2. Make sure there are at least 3 in. (76 mm) of mix in the hopper and that the level of mix is not above the mix delivery hole on the side of the feed tube. Note: The level of mix must be below the mix delivery hole on the side of the feed tube. Failure to follow this instruction may result in lower product quality when normal operation is resumed. 3. Press the STANDBY key. The light will illuminate, indicating that the unit is operating as a refrigerator for product in the hopper and freezing cylinder. 4. To remove the unit from the standby mode, press the AUTO key. The STANDBY light will extinguish, indicating the unit has resumed the normal operating mode. O OFF WASH I ON AUTO MIX MIX LOW STANDBY MIX OUT

When the unit cycles off, place the feed tube in its

original position (mix delivery hole end down) and install air orifice. Figure 5-2 Feed Tube Position during Normal Operation Important! The standby mode must not be used instead of daily disassembly, cleaning, and sanitizing. WASH Key When the WASH key is pressed, the light comes on, indicating beater motor operation. The standby or auto mode must be canceled first to activate the wash mode. AUTO Key When the AUTO key is pressed, the light comes on, indicating that the main refrigeration system has been activated. In the auto mode, the wash or standby functions are automatically canceled. The mix refrigeration function is automatically locked in to maintain the temperature of the mix in the mix hopper. Note: An indicating light and an audible tone will sound whenever a mode of operation has been pressed. To cancel any function, press the key again. The light and mode of operation will shut off. Indicator Light—MIX LOW Located on the front of the machine is a mix level indicating light. When the light is flashing, it indicates that the mix hopper has a low supply of mix and should be refilled as soon as possible. Always maintain at least 3 in. (76 mm) of mix in the hopper. If you neglect to add mix, a freeze-up may occur. This will cause eventual damage to the beater, blades, drive shaft, and freezer door. Indicator Light—MIX OUT When the Mix Out symbol is illuminated, the mix hopper has almost completely exhausted and has an insufficient supply of mix to operate the freezer. At this time, the Auto mode is locked out and the freezer will be placed in the Standby mode. To initiate the refrigeration system, add mix to the mix hopper and touch the Auto symbol. The freezer will automatically begin operation. Reset Button The reset button is located on the side of the C152 unit and on the front of the C161 unit. The reset protects the beater motor from an overload condition. If an overload occurs, the reset mechanism will trip. To properly reset the freezer: 1. Press the AUTO key to cancel the cycle. 2. Turn the power switch to the OFF position. 3. Wait two or three minutes and then press the reset button firmly. CAUTION! DO NOT use metal objects to press the reset button. Failure to follow this instruction may result in electrocution. 4. Turn the power switch to the ON position. 5. Press the WASH key and observe the freezer's performance. If the beater motor is turning properly, press the WASH key to cancel the cycle. 6. Press the AUTO key on both sides of the unit to resume normal operation. If the freezer shuts down again, contact a Taylor service technician.

The feed tube maintains overrun and allows enough mix

to enter the freezing cylinder after a draw. One end of the tube has a mix delivery hole on the side, and the other end does not. Figure 5-3 The feed tube serves two purposes. • Normal Operation: After priming the machine, the end of the feed tube with the mix delivery hole is placed in the mix inlet hole, and the air orifice is installed. Every time the draw handle is raised, new mix and air from the hopper will flow down into the freezing cylinder. This will keep the freezing cylinder properly loaded and will maintain overrun. Figure 5-4 Feed Tube Position during Normal Operation • Standby Operation: During long “no sale” periods, the air orifice is removed and the feed tube is inverted. The end of the feed tube without the mix delivery hole is placed in the mix inlet hole to prevent mix from entering the freezing cylinder. Figure 5-5 Feed Tube Position during Standby Operation Note: Make sure the level of mix is below the mix delivery hole in the side of the feed tube. Failure to follow this instruction may result in lower product quality when normal operation is resumed.

The Model C161 has been selected to illustrate the

pictured step-by-step operating procedures. The models in this manual are similar. They have a 1.5 qt. (1.4 L) capacity freezing cylinder. The mix flows by gravity from the hopper to the freezing cylinder through a feed tube. Model C152 is a counter model with a single spout door. Model C161 is a counter model with three spout doors. Two individual flavors are available from the end spouts and an equal combination of both is dispensed through the center spout to create a twist effect. We begin our instructions at the point where we enter the store in the morning and find the parts disassembled and laid out to air dry from the previous night's cleaning. These opening procedures will show you how to assemble these parts into the machine, sanitize them, and prime the machine with fresh mix in preparation to serve your first portion. Duplicate the procedures where they apply for the second freezing cylinder. Figure 6-1 If you are disassembling the machine for the first time or need information to get to the starting point in our instructions, turn to "Disassembly" on page 6-7, and start there. Assembly Note: When lubricating parts, use an approved food grade lubricant (example: Taylor Lube). 1. Lubricate the groove on the beater drive shaft. With the opening of the cup seal facing away from the hex end, slide the seal into the groove. Apply an even coat of lubricant to the seal and the shaft. Do not lubricate the hex end of the beater drive shaft. Figure 6-2 2. Insert the beater assembly through the rear shell bearing at the back of the freezing cylinder and engage the hex end firmly into the female socket. When properly seated, the beater will not protrude beyond the front of the freezing cylinder. Figure 6-3 3. Repeat step 1 and step 2 for the other side of the machine. 11457 11456

Place the large O-rings into the grooves on the back

of the machine door and lubricate. Figure 6-4 5. Slide the front bearings over the baffle rods so that the flanged edge is against the door. Place the white plastic guide bearings on the end of the baffle rods. Do not lubricate the front bearings or the guide bearings. Figure 6-5 6. Slide the slotted portion of the handscrews into the slots in the freezer door. 7. With both hands, hold the sides of the freezer door and insert the baffle rods into the center of the beater assemblies. The white guide bearings must fit securely in the holes of the drive shafts. 8. Finger-tighten the handscrews, making sure they are tightened equally and that the door is snug. Do not overtighten the handscrews. Figure 6-6 Important! Handscrew and door damage can result if the handscrews are overtightened or if one handscrew is tightened more than the other. 9. (For Model C161 Only) Install the valve seal into the grooves on the center draw valve and lubricate. This special seal will prevent the mix in one freezing cylinder from traveling into the second cylinder. Figure 6-7 10335 10336 11070C

10. Slide the two O-rings into the grooves on the

remaining draw valves and lubricate. Figure 6-8 11. Lubricate the inside of the freezer door spouts from the bottom. Insert the draw valves into the freezer door from the bottom until the slot in the draw valves comes into view. Figure 6-9 12. Slide the O-ring onto each pivot pin and lubricate. Figure 6-10 13. Slide the tip of the draw handle into the slot of the draw valve, starting from the right. Slide the short pivot pin through the far right draw handle. Slide the long pivot pin through the far left and middle draw handles. Figure 6-11 11070 10131a

14. Snap the design caps over the bottom of the freezer

door spouts. Figure 6-12 15. Install the O-ring onto the groove of the air orifice. Do not lubricate the O-ring. Figure 6-13 Note: Make sure the hole in the orifice is clean and not clogged. If the hole in the air orifice is clogged, use soap and hot water to clear. Do not enlarge the hole in the air orifice. 16. Install the air orifice to the end of the feed tube without the hole in the side. Figure 6-14 17. Lay the feed tube with air orifice in the bottom of the mix hopper. 18. Lay the feed tubes in the bottom of the mix hoppers. 19. Install the front drip tray and splash shield under the freezer door. Figure 6-15

20. Install the drip pan.

Figure 6-16 Sanitizing 1. Prepare an approved 100 PPM sanitizing solution (examples: 2.5 gal. [9.5 L] of Kay-5®or 2 gal. [7.6 L] of Stera-Sheen®). Use warm water and follow the manufacturer's specifications. 2. Pour 1 gal. (3.8 L) of sanitizing solution into the hopper and allow it to flow into the freezing cylinder. Figure 6-17 3. While the solution is flowing into the freezing cylinder, brush clean the mix hopper, the mix inlet hole, and the feed tube. Figure 6-18 Figure 6-19 4. Place the power switch in the ON position. Figure 6-20 12029 12235 12019 13093 131559

Press the WASH key to cause the sanitizing solution

in the freezing cylinder to be agitated. Allow it to agitate for five minutes. Figure 6-21 6. Place an empty pail beneath the door spouts. Momentarily open the center draw valve to sanitize the center door spout. Open the remaining draw valves to remove all of the sanitizing solution. When the sanitizer stops flowing from the door spouts, close the draw valves. Press the WASH key to cancel the wash mode. 7. With sanitized hands, stand the feed tube with air orifice in the corner of the mix hopper. Figure 6-22 8. Repeat step 1 through step 7 for the other side of the machine. Priming Prime the machine as close as possible to the time of first product draw. 1. With a pail beneath the door spouts, open the draw valves. Fill the mix hopper with fresh mix and allow it to flow into the freezing cylinder. This will force out any remaining sanitizing solution. When mix is flowing full strength from the door spouts, close the draw valves. Note: Use only fresh mix when priming the machine. 2. When the mix has stopped bubbling down into the freezing cylinder, install the feed tube and air orifice in the mix inlet hole. Figure 6-23 3. Press the AUTO key. When the unit cycles off, the product will be ready to serve. Figure 6-24 13054w 131558 300113 30039_A 13054a 131560

(For Model C161) Repeat step

1 through step 3 for the other side of the machine. 5. Place the mix hopper cover in position. Closing Procedure To disassemble these units, the following items will be needed: • Two cleaning pails • Sanitized stainless steel rerun can with lid • Necessary brushes (provided with machine) • Cleaner • Single-service towels Draining Product from the Freezing Cylinder 1. Press the AUTO key to cancel operation. Press the MIX REF key to cancel hopper refrigeration. These operations should be canceled as far ahead of cleaning time as possible to allow frozen product to soften for easier cleaning. Remove the mix hopper cover, and feed tube from the machine. Take them to the sink for cleaning. 2. If local health codes permit the use of rerun, place a sanitized NSF-approved stainless steel rerun container beneath the door spouts. Press the WASH key and open the draw valves. When all the product stops flowing from the door spouts, close the draw valves and press the WASH key to cancel the wash mode. Place the sanitized lid on the rerun container and place it in the walk-in cooler. Note: If local health codes do not permit the use of rerun, the product must be discarded. Follow the instructions in the previous step, except drain the product into a pail and properly discard the mix. ! ALWAYS FOLLOW LOCAL HEALTH CODES. 3. Repeat step 1 through step 2 for the other side of the machine. Rinsing 1. Pour 1 gal. (3.8 L) of cool, clean water into the mix hopper. With the brushes provided, scrub the mix hopper and the mix inlet hole. 2. With a pail beneath the door spouts, press the WASH key and open the draw valves. 3. Drain all the rinse water from the freezing cylinder. When the rinse water stops flowing from the door spout, close the draw valves and press the WASH key to cancel. Repeat this procedure until the rinse water being drawn from the freezing cylinder is clear. 4. Repeat step 1 through step 3 for the other side of the machine. Cleaning 1. Prepare an approved 100 PPM cleaning solution (examples: 2.5 gal. [9.5 L] of Kay-5®or 2 gal. [7.6 L] of Stera-Sheen®). Use warm water and follow the manufacturer's specifications. 2. Pour 1 gal. (3.8 L) of cleaning solution into the mix hopper and allow it to flow into the freezing cylinder. 3. While the solution is flowing into the freezing cylinder, brush clean the mix hopper, the mix inlet hole, and the mix level probe. 4. Press the WASH key to cause the cleaning solution in the freezing cylinder to agitate. 5. Place an empty pail beneath the door spouts and raise the draw valve. Draw off all the cleaning solution. When the solution stops flowing from the door spouts, close the draw valves. Press the WASH key to cancel. 6. Repeat step 1 through step 5 for the other side of the machine. Disassembly 1. Remove the handscrews and the freezer door. Remove the beater assemblies from the freezing cylinders and take these parts to the sink for cleaning. 2. Remove the front drip tray, splash shield, and drip pans from the machine. Take them to the sink for cleaning.

Prepare a sink with an approved cleaning solution

(examples: Kay-5®or Stera-Sheen®). Use warm water and follow the manufacturer's specifications. Important! Follow label directions. Too strong of a solution can cause parts damage, while too weak of a solution will not provide adequate cleaning. Make sure all brushes provided with the machine are available for brush cleaning. 2. Remove the cup seals from the drive shafts of the beater assemblies. 3. From the freezer door, remove design caps, pivot pins, draw handles, and draw valves. Remove all O-rings. Note: To remove O-rings, use a single-service towel to grasp the O-ring. Apply pressure in an upward direction until the O-ring pops out of its groove. With the other hand, push the top of the O-ring forward; it will roll out of the groove and can be easily removed. If more than one O-ring needs to be removed, always remove the rear O-ring first to allow the O-ring to slide over the forward rings without falling into the open grooves. 4. Remove the large O-rings, front bearings, and guide bearings from the back of the freezer door. 5. Return to the machine with a small amount of cleaning solution. With the black bristle brush, brush clean the rear shell bearings at the back of the freezing cylinders. Note: If the drip pan was filled with an excessive amount of mix, the drive shaft O-ring of the beater assembly should be replaced or properly lubricated. 6. Thoroughly brush clean all disassembled parts in the cleaning solution. Make sure all lubricant and mix film is removed. Take particular care to brush clean the draw valve cores in the freezer door. Place all the cleaned parts on a clean, dry surface to air dry overnight. 7. Wipe clean all exterior surfaces of the machine.

ALWAYS FOLLOW LOCAL HEALTH CODES.

! Section 7 7-1 085592-M Operator Checklist 7 Operator Checklist During Cleaning and Sanitizing NOTICE! Cleaning and sanitizing schedules are governed by federal, state, or local regulatory agencies, and must be followed accordingly. If the unit has a Standby mode, it must not be used in lieu of proper cleaning and sanitizing procedures and frequencies set forth by the ruling health authority. The following checkpoints should be stressed during the cleaning and sanitizing operations. Troubleshooting Bacterial Count  Thoroughly clean and sanitize the machine regularly, including complete disassembly and brush cleaning.  Use all brushes supplied for thorough cleaning. The brushes are specially designed to reach all mix passageways.  Use the smaller, white bristle brush to clean the mix inlet hole that extends from the mix hopper down to the rear of the freezing cylinder.  Use the black bristle brush to thoroughly clean the rear shell bearing located at the rear of the freezing cylinder. Make sure to have a generous amount of cleaning solution on the brush.  If local health codes permit the use of rerun, make sure the mix rerun is stored in a sanitized, covered stainless steel container and is used the following day. Do not prime the machine with rerun. When using rerun, skim the foam and discard. Mix the rerun with fresh mix in a ratio of 50:50 during the day's operation.  On a designated day of the week, run the mix as low as feasible and discard after closing. This will break the rerun cycle and reduce the possibility of high bacteria and coliform counts.  Properly prepare the cleaning and sanitizing solutions. Read and follow label directions carefully. Too strong of a solution may damage the parts, and too weak of a solution will not do an adequate job of cleaning or sanitizing.  The temperature of the mix in the mix hopper and walk-in cooler should be below 40F (4.4C). Regular Maintenance Checks  Check the rear shell bearing for signs of wear (excessive mix leakage in rear drip pan) and make sure it is properly cleaned.  Using a screwdriver and cloth towel, keep the rear shell bearing and the female hex drive socket clean and free of lubricant and mix deposits.  Dispose of O-rings or seals if they are worn, torn, or fit too loosely, and replace with new ones.  Follow all lubricating procedures as outlined in "Assembly" on page 6-1.  If your machine is air cooled, check the condenser for an accumulation of dirt and lint. A dirty condenser will reduce the efficiency and capacity of the machine. Condensers should be cleaned monthly with a soft brush. Never use screwdrivers or other metal probes to clean between the fins. Note: For machines equipped with an air filter, it will be necessary to vacuum clean the filters on a monthly schedule.  If your machine is equipped with an auxiliary refrigeration system, check the auxiliary condenser for accumulation of dirt and lint. A dirty condenser will reduce the refrigeration capacity of the mix hopper. Condensers must be cleaned monthly with a soft brush. Never use screwdrivers or other metal probes to clean between the fins. Failure to comply may result in electrocution.

If your machine is water cooled, check the water

lines for kinks or leaks. Kinks can occur when the machine is moved back and forth for cleaning or maintenance purposes. Deteriorated or cracked water lines should be replaced only by a Taylor service technician. Winter Storage If the place of business is to be closed during the winter months, it is important to protect the freezer by following certain precautions, particularly if the building is subject to freezing conditions. Important! On water-cooled freezers, disconnect the water supply. Relieve pressure on the spring in the water valve. Use air pressure on the outlet side to blow out any water remaining in the condenser. This is extremely important. Failure to follow this procedure may cause severe and costly damage to the refrigeration system. Your local Taylor distributor can perform this service for you. • Disconnect the freezer from the main power source to prevent possible electrical damage. • Wrap detachable parts of the freezer, such as the beater assembly and freezer door, and place them in a protected dry place. Rubber trim parts and gaskets can be protected by wrapping them with moisture- proof paper. • All parts should be thoroughly cleaned of dried mix or lubrication accumulations, which attract mice and other vermin.

No product is being

dispensed. a. The power switch is in the OFF position. a. Place the power switch in the AUTO position. 5-2 b. The mix level is inadequate in the mix hopper. b. Fill the mix hopper with mix. 5-3 c. The beater motor overloaded. c. Reset the freezer. 5-3 d. The unit is unplugged at the wall receptacle. d. Plug in the power cord. 1-1 e. The circuit breaker is tripped, or the fuse is blown. e. Place the circuit breaker in the ON position or replace the fuse. --- f. The freezer door is incorrectly assembled. f. See "Section 6: Operating Procedures" for proper installation. 6-1 g. Product is being drawn off in excess of the freezer’s capacity. g. Stop drawing product and allow the unit to recover. --- 2. The machine will not operate in the AUTO mode. a. The control is set too cold. a. Contact service technician. 1-3 b. The refrigeration system is not activated. b. Momentarily raise the draw switch to activate the refrigeration system. 5-3 c. The circuit breaker is tripped, or the fuse is blown. c. Place the circuit breaker in the ON position or replace the fuse. --- d. The beater motor overloaded, causing a loss of power to the power switch. d. Reset the freezer. 5-3 3. The product is too stiff. a. The control is set too cold. a. Contact service technician. --- 4. The product is too soft. a. The control is set too warm. a. Contact service technician. --- b. The air tube is not installed. b. Install the air tube in the mix inlet hole at the bottom of the mix hopper. 6-6 c. Out-drawing the freezer's capacity. c. Two 4 oz. (113.4 g) servings in one minute. --- 5. The freezing cylinder walls are scored. a. Operating freezer without the front bearing on the freezer door. a. Install the front bearing on the freezer door. 6-1 b. The gear unit or the direct drive is out of alignment. b. Contact service technician. --- 6. Excessive leakage in rear drip pan. a. A worn or defective O-ring is on the beater drive shaft. a. Replace O-rings every 3 months. 9-1 b. The rear shell bearing is worn. b. Contact service technician. --- c. Incorrect lubricant was used. c. Use food grade lubricant (example: Taylor Lube). 6-1 d. Inadequate lubrication of beater drive shaft. d. Lubricate the beater drive shaft properly. 6-1

The draw valve is

leaking. a. Incorrect lubricant was used. a. Use food grade lubricant (example: Taylor Lube). 6-1 b. Worn or defective O-rings are on the draw valve. b. Replace O-rings every 3 months. 9-1 c. Inadequate lubrication of draw valve. c. Lubricate the draw valve properly. 6-1 8. Product is not feeding into the freezing cylinder. a. The mix level is inadequate in the mix hopper. a. Fill the mix hopper with mix. 5-3 b. The air orifice is not installed. b. Install the air orifice in the air tube. 6-6 c. The air tube is installed incorrectly. c. Install the air tube in the mix inlet hole, using the end with the small hole in the side. 6-6 d. The mix inlet hole is frozen. d. Contact service technician. --- 9. The unit goes out on overload excessively. a. There are too many appliances plugged into the circuit. a. A separate 20 A circuit is needed for the freezer to operate properly. --- b. An extension cord has been placed between the power cord and the wall receptacle. b. If the extension cord is used, it must match the power cord in size of circuit ampacity. --- 10. Mix from one freezing cylinder bleeds over to the second cylinder. a. The center draw valve seal is worn, or improperly lubricated. a. Lubricate properly and replace seal every 3 months. 6-1, 9-1 Problem Probable Cause Remedy Page Ref.

Parts Replacement Schedule

9 Parts Replacement Schedule Maintenance Intervals Table 9-1 Part Description Every 3 Months Every 6 Months Annually C152 Qty. C161 Qty. Beater Drive Shaft Cup Seal X 1 2 Freezer Door O-Ring X 1 2 Freezer Door Front Bearing X 1 2 Freezer Door Guide Bearing X 1 2 Draw Valve O-Ring X 2 4 Center Draw Valve Seal X N/A 1 Pivot Pin O-Ring X 1 2 Black Bristle Brush, 1” x 2” Inspect and replace if necessary. Minimum 1 1 Double Ended Brush Inspect and replace if necessary. Minimum 1 1 White Bristle Brush, 1” x 2” Inspect and replace if necessary. Minimum 1 1 White Bristle Brush, 3” x 7” Inspect and replace if necessary. Minimum 1 1 Air Orifice O-Ring X Inspect and replace if necessary. Minimum 1 2

Limited Warranty on Equipment

10 Limited Warranty on Equipment TAYLOR COMPANY LIMITED WARRANTY ON FREEZERS Taylor Company is pleased to provide this limited warranty on new Taylor-branded freezer equipment (the “Product”) available from Taylor to the market generally to the original purchaser only. LIMITED WARRANTY Taylor warrants the Product against failure due to defects in materials or workmanship under normal use and service as follows. All warranty periods begin on the date of original Product installation. If a part fails due to defects during the applicable warranty period, Taylor, through a Taylor-authorized Taylor distributor or service agency, will provide a new or re-manufactured part, at Taylor's option, to replace the failed defective part at no charge for the part. Except as otherwise stated herein, these are Taylor's exclusive obligations under this limited warranty for a Product failure. This limited warranty is subject to all provisions, conditions, limitations, and exclusions listed below and on the reverse (if any) of this document. Table 10-1 LIMITED WARRANTY CONDITIONS 1. If the date of original installation of the Product cannot be verified, then the limited warranty period begins ninety (90) days from the date of Product manufacture (as indicated by the Product serial number). Proof of purchase may be required at time of service. 2. This limited warranty is valid only if the Product is installed and all required service work on the Product is performed by a Taylor-authorized distributor or service agency, and only if genuine, new Taylor parts are used. 3. Installation, use, care, and maintenance must be normal and in accordance with all instructions contained in the Taylor Operator's Manual. 4. Defective parts must be returned to the Taylor-authorized distributor or service agency for credit. 5. The use of any refrigerant other than that specified on the Product's data label will void this limited warranty. Product Part Limited Warranty Period Soft Serve Insulated Shell Assembly Five (5) Years Frozen Yogurt Shakes Refrigeration Compressor (except service valve) Five (5) Years Smoothies Beater Motors Two (2) Years Frozen Beverage Beater Drive Gear Two (2) Years Batch Desserts Printed Circuit Boards and Softech™ Controls beginning with Serial Number H8024200 Two (2) Years Parts Not Otherwise Listed in This Table or Excluded Below One (1) Years

LIMITED WARRANTY ON EQUIPMENT

085592-M Limited Warranty on 10 LIMITED WARRANTY EXCEPTIONS This limited warranty does not cover: 1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing, or handling of defective parts, replacement parts, or new Products. 2. Normal maintenance, cleaning, and lubrication as outlined in the Taylor Operator's Manual, including cleaning of condensers. 3. Replacement of wear items designated as Class 000 parts in the Taylor Operator's Manual. 4. External hoses, electrical power supplies, and machine grounding. 5. Parts not supplied or designated by Taylor, or damages resulting from their use. 6. Return trips or waiting time required because a service technician is prevented from beginning warranty service work promptly upon arrival. 7. Failure, damage, or repairs due to faulty installation, misapplication, abuse, no or improper servicing, unauthorized alteration, or improper operation or use as indicated in the Taylor Operator's Manual, including but not limited to the failure to use proper assembly and cleaning techniques, tools, or approved cleaning supplies. 8. Failure, damage, or repairs due to theft, vandalism, wind, rain, flood, high water, water, lightning, earthquake, or any other natural disaster, fire, corrosive environments, insect or rodent infestation, or other casualty, accident, or condition beyond the reasonable control of Taylor; operation above or below the electrical or water supply specification of the Product; components repaired or altered in any way so as to, in the judgment of the Manufacturer, adversely affect performance, or normal wear or deterioration. 9. Any Product purchased over the Internet. 10. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the inadequacy or interruption of electrical service. 11. Electricity or fuel costs, or increases in electricity or fuel costs for any reason whatsoever. 12. Damages resulting from the use of any refrigerant other than that specified on the Product's data label. 13. Any cost to replace, refill, or dispose of refrigerant, including the cost of refrigerant. 14. Any special, indirect, or consequential property or commercial damage of any nature whatsoever. Some jurisdictions do not allow the exclusion of incidental or consequential damages, so this limitation may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights that vary from jurisdiction to jurisdiction.

LIMITED WARRANTY ON EQUIPMENT

10-3 085592-M Limited Warranty on Equipment 10 LIMITATION OF WARRANTY THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, AND/ OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER'S SOLE REMEDY WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVE COMPONENTS UNDER THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIAL OR INCIDENTAL DAMAGES (INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS, PROPERTY DAMAGES, OR SERVICE EXPENSES ARE EXPRESSLY EXCLUDED. THE EXPRESS WARRANTIES MADE IN THIS LIMITED WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER. LEGAL REMEDIES The owner must notify Taylor in writing by certified or registered letter to the following address of any defect or complaint with the Product, stating the defect or complaint and a specific request for repair, replacement, or other correction of the Product under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies. Taylor Company 750 N. Blackhawk Blvd. Rockton, IL 61072, U.S.A.

Limited Warranty on Parts

11 Limited Warranty on Parts TAYLOR COMPANY LIMITED WARRANTY ON GENUINE TAYLOR PARTS Taylor Company is pleased to provide this limited warranty on genuine, new Taylor replacement components and parts (the “Parts”) available from Taylor to the market generally to the original purchaser only. LIMITED WARRANTY Taylor warrants the Parts against failure due to defect in materials or workmanship under normal use and service as follows. All warranty periods begin on the date of original installation of the Part in the Taylor unit. If a Part fails due to defects during the applicable warranty period, Taylor, through a Taylor-authorized distributor or service agency, will provide a new or remanufactured Part, at Taylor's option, to replace the failed defective Part at no charge for the Part. Except as otherwise stated herein, these are Taylor's exclusive obligations under this limited warranty for a Part failure. This limited warranty is subject to all provisions, conditions, limitations, and exclusions listed below and on the reverse (if any) of this document. Table 11-1 LIMITED WARRANTY CONDITIONS 1. If the date of original installation of the Part cannot be otherwise verified, proof of purchase may be required at time of service. 2. This limited warranty is valid only if the Part is installed and all required service work in connection with the Part is performed by a Taylor-authorized distributor or service agency. 3. The limited warranty applies only to Parts remaining in use by their original owner at their original installation location in the unit of original installation. 4. Installation, use, care, and maintenance must be normal and in accordance with all instructions contained in the Taylor Operator's Manual. 5. Defective Parts must be returned to the Taylor-authorized distributor or service agency for credit. 6. This warranty is not intended to shorten the length of any warranty coverage provided pursuant to a separate Taylor limited warranty on freezer or grill equipment. 7. The use of any refrigerant other than that specified for the unit in which the Part is installed will void this limited warranty. Part's Warranty Class Code or Part Limited Warranty Period Class 103 Parts¹ Three (3) Months Class 212 Parts² Twelve (12) Months Class 512 Parts Twelve (12) Months Class 000 Parts No Warranty Taylor Part #072454 (Motor-24VDC *C832/C842*) Four (4) Years 1, 2 Except that Taylor Part #032129SER2 (Compressor-Air-230V SERV) and Taylor Part #075506SER1 (Compressor-Air-115V 60HZ) shall have a limited warranty period of twelve (12) months when used in Taylor freezer equipment and a limited warranty period of two (2) years when used in Taylor grill equipment.

LIMITED WARRANTY ON PARTS

085592-M Limited Warranty on Parts 11 LIMITED WARRANTY EXCEPTIONS This limited warranty does not cover: 1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing, or handling of defective Parts, replacement Parts, or new Parts. 2. Normal maintenance, cleaning, and lubrication as outlined in the Taylor Operator's Manual, including cleaning of condensers or carbon and grease buildup. 3. Required service, whether cleaning or general repairs, to return the cooking surface assemblies, including the upper platen and lower plate, to an operational condition to achieve proper cooking or allow proper assembly of release sheets and clips as a result of grease buildup on the cooking surfaces, including but not limited to the platen and plate, sides of the shroud, or top of the shroud. 4. Replacement of cooking surfaces, including the upper platen and lower plate, due to pitting or corrosion (or in the case of the upper platen, due to loss of plating) as a result of damage due to the impact of spatulas or other small wares used during the cooking process or as a result of the use of cleaners, cleaning materials, or cleaning processes not approved for use by Taylor. 5. Replacement of wear items designated as Class 000 Parts in the Taylor Operator's Manual, as well as any release sheets and clips for the Product's upper platen assembly. 6. External hoses, electrical power supplies, and machine grounding. 7. Parts not supplied or designated by Taylor, or damages resulting from their use. 8. Return trips or waiting time required because a service technician is prevented from beginning warranty service work promptly upon arrival. 9. Failure, damage, or repairs due to faulty installation, misapplication, abuse, no or improper servicing, unauthorized alteration or improper operation or use as indicated in the Taylor Operator's Manual, including but not limited to the failure to use proper assembly and cleaning techniques, tools, or approved cleaning supplies. 10. Failure, damage or repairs due to theft, vandalism, wind, rain, flood, high water, water, lightning, earthquake, or any other natural disaster, fire, corrosive environments, insect or rodent infestation, or other casualty, accident or condition beyond the reasonable control of Taylor; operation above or below the gas, electrical, or water supply specification of the unit in which a part is installed; Parts or the units in which they are installed repaired or altered in any way so as to, in the judgment of Taylor, adversely affect performance, or normal wear or deterioration. 11. Any Part purchased over the Internet. 12. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the inadequacy or interruption of electrical service. 13. Electricity, gas, or other fuel costs, or increases in electricity or fuel costs for any reason whatsoever. 14. Damages resulting from the use of any refrigerant other than that specified for the unit in which the Part is installed. 15. Any cost to replace, refill, or dispose of refrigerant, including the cost of refrigerant. 16. Any special, indirect, or consequential property or commercial damage of any nature whatsoever. Some jurisdictions do not allow the exclusion of incidental or consequential damages, so this limitation may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from jurisdiction to jurisdiction.

LIMITED WARRANTY ON PARTS

11-3 085592-M Limited Warranty on Parts 11 LIMITATION OF WARRANTY THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, AND/ OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER'S SOLE REMEDY WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS UNDER THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIAL OR INCIDENTAL DAMAGES, (INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS, PROPERTY DAMAGES OR SERVICE EXPENSES ARE EXPRESSLY EXCLUDED. THE EXPRESS WARRANTIES MADE IN THIS LIMITED WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER. LEGAL REMEDIES The owner must notify Taylor in writing by certified or registered letter to the following address of any defect or complaint with the Part, stating the defect or complaint and a specific request for repair, replacement, or other correction of the Part under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies. Taylor Company 750 N. Blackhawk Blvd. Rockton, IL 61072, U.S.A.

Other Freezer Manuals