Wegener UNITY 4600 Quick Start Manual

Text of the manual

800032-02 Rev. G

1 General Information If equipped with a receiver card, the Unity 4600 receives an L-band RF carrier from an external LNB, demodulates the carrier, and then extracts the MPEG transport stream. If equipped with an ASI transport card, it decodes the ASI line code and extracts the resulting transport stream. In both cases, if conditional access has been applied, the Unity 4600 then descrambles the transport stream (or individual programs) if authorized. It then supplies that stream to the DVB-ASI output (with program mapping, if enabled). It also may decompress a selected program to provide composite video and two stereo-audio outputs. (The compressed audio formats may be MPEG or Dolby AC-3.) This guide provides information for setup and initial operation of the Unity 4600. For a full description of refer to the Unity 4600 User's Reference Manual (p/n 800032-01) available on the worldwide web at www.wegener.com. Unpacking and Inspection The box containing the unit should include: Carefully unpack the items and inspect for obvious signs of physical damage that might have occurred during shipment. Any damage claims must be reported to the carrier immediately. Be sure to check the package contents carefully for important documents and materials. Note: Save the original packing materials and shipping containers in case the unit must be returned for repair. Packing the unit in another container in such a way that the unit is damaged will void the warranty. Environmental Operating Conditions and Physical Specifications The table below lists the Unity 4600 environmental limits and physical specifications Unity 4600 PROFESSIONAL MEDIA RECEIVER Quick Start Guide � Unity 4600 � this Quick Start Guide � power cord � UL Safety sheet Item/Limit Specification Use Indoor only Altitude Up to 2000 meters Temperature Range +10° C to +50° C Relative Humidity (max.) Maximum relative humidity of 80% for temperatures up to 31° C decreasing linearly to 50% relative humidity at 40° C. Weight ~10.5 pounds (4.76 kg) Dimensions (H x W x D) 1.75" x 19" x 15" or 44.5 mm x 483 mm x 381 mm Input Power Rating 90-132Vac or 175-264Vac, 43 Watt, 50/60 Hz

QUICK START GUIDE

2 800032-02 Rev. G www.wegener.com Warnings To avoid damage to this and other equipment, or personal injury, the following items should be strictly observed. Elevated Operating Ambient When equipment is installed in a closed or multi-unit rack assembly, the operating ambient of the rack environment may be greater than the room ambient. Therefore, consideration should be given to the ambient air temperature within the rack, and not just inside the room, when deciding if the maximum recommended ambient operating temperature (TMRA) is being met. Reduced Air Flow Equipment should be installed such that airflow required for safe operation of the equipment is not compromised. The Unity 4600 may be arranged in a rack without empty space between units if heat rise is prevented by ensuring its side vents remain unblocked with adequate clearance around the vent holes. Mechanical Loading Mounting of the equipment in a rack should be such that a hazardous condition is not produced by uneven loading. This unit is not very heavy, but total rack loading must be considered. Also, do not rest any unsupported equipment on your Unity 4600. Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on overcurrent protection and supply wiring. Ensure that the total rack or breaker power consumption does not exceed the limits of the AC branch circuit. Appropriate consideration of equipment ratings should be used when addressing this concern. Reliable Earthing Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (use of power strips, chassis ground lugs, etc.). Rack Installation When installed in an equipment rack, it is best that the Unity 4600 be supported by angle brackets or cross supports. These should be screwed or bolted securely to the equipment rack, and be capable of supporting the unit and its connecting cables. Do NOT install the unit if you have doubts about the unit being safely supported. There are also four holes in the front brackets which are designed to accept anchoring screws. It is essential that these brackets be used so the unit cannot be moved forward and fall from the rack. It is always best to install the angle brackets or cross-members before setting the unit in place. Then, prior to installing cables, put anchored screws or bolts-and-nuts into place on the front brackets. Failure to do this can lead to pushing the unit out the front of the rack in later steps. WARNING: FCC-Mandated Suppression of Radio Frequency Emissions This is a Class A product. In a domestic environment this product may cause radio interference for which the user may need to take mitigating action. If the Ethernet port has a cable connected to it, that cable must be properly shielded and grounded to minimize RF emissions that could interfere with nearby equipment.

QUICK START GUIDE

www.wegener.com 800032-02 Rev. G 3 System Setup Figure 1 illustrates a typical system setup for the Unity 4600. Figure 1: Unity 4600 system connections Rear Panel Connections Figure 2 and 3 illustrates the rear panel views for the Unity 4600 connections. DTMF is not available for units manufactured after 10/22/2007. Figure 2: Unity 4600 rear panel with DTMF Figure 3: Unity 4600 rear panel without DTMF Table 1 lists connector types, pin numbers, and signal descriptions for each of the connectors. Table 1: Unity 4600 rear panel connections Connector Designation Type Pin Signal Description 115/230 VAC Std. IEC Receptacle AC line in

QUICK START GUIDE

4 800032-02 Rev. G www.wegener.com ETHERNET RJ45 Jack 1 TXDO + 2 TXDO - 3 RXDI + 4 Shorted together, then terminated into an AC ground. 5 6 RXDI - 7 Shorted together, then terminated into an AC ground. SERIAL CONTROL RS232, 9 pin D female jacks 1 DCD (internally pulled to +5V) 2 RxD (data output) 3 TxD (data input) 4 DTR (not connected) 5 GND 6 DSR (internally pulled to +5V) 7 RTS (internally pulled to +5V,may be upgraded for handshaking) 8 CTS (not used presently, may be upgraded for handshaking) 9 RI (internally pulled to +5V, with weak current limiting) ALARM/ CUEING 10-pin male header (mates to removable terminal strip) 1 OK (COM closes here when OK) 2 COM: 3 Alarm (COM closes here on alarm or if power is off) 4 GND 5 Cue Relay #1: N.C. contact 6 Cue Relay #1: Common contact 7 Cue Relay #1: N.O. contact 8 Cue Relay #2: N.C. contact 9 Cue Relay #2: Common contact 10 Cue Relay #2: N.O. contact DTMF* 3-pin male header (mates to removable terminal strip) 1 DTMF tone, non-inverted output 2 GND 3 Alarm (COM closes here on alarm or if power is off) AUDIO (same for both ports 1 and 2) 6-pin male header (mates to removable terminal strip) 1 Right '+' 2 Right GND 3 Right '-' 4 Left '+' 5 Left GND 6 Left '-' COMPOSITE VIDEO OUT BNC Jack Composite Video Output ASI OUT BNC Jack DVB-ASI Output Connector Designation Type Pin Signal Description

QUICK START GUIDE

www.wegener.com 800032-02 Rev. G 5 Front Panel Controls Figure 4 shows the Unity 4600's front panel controls and indicators. There are three major parts of the front panel: the liquid-crystal display (LCD), the six push buttons, and the eight LED indicators Figure 4: Unity 4600 front panel User Interface In operation, the Unity 4600 Home screen appears on the LCD as shown in Figure 5 (if using an L-band receiver card with 4-way RF switching input - consult the online User's Manual if using an ASI input option): Figure 5: Unity 4600 Home Screen Where pp...pp is either, in order of priority (and as available): (1) the first eight characters of the user- supplied Channel Label; or (2) the first eight characters of the Program's Service Descriptor; or (3) Progr xx (for Program # 'xx'), or PID xxxx (for video PID 'xxxx', where 'xxxx' is in hexadecimal notation). fffff.ff is the downlink frequency in MHz. y is the selected RF feed port number and the MM…MM field is a marquee. The MM…MM marquee alternates between messages indicating RF signal level (0 to 100 where 100 is max power and 0 is min), Eb/No (if locked on a carrier), or others indicating unit state or the presence of faults. Note that the flashing arrow at the lower right of the display is a prompt indicating that the user may find other menu screens by pressing the right or left arrow buttons on the front panel. LNB PWR ** 2-pin male header (mates to removable terminal-strip) 1 LNB DC Output positive leg 2 LNB DC Output return leg RF IN -1 through 4 Type F coax jacks 4-way RF Switch Inputs Front-panel monitor option AUDIO *** ¼" stereo phone jack Stereo audio headphone monitor, selectable between audio ports 1 or 2 Front-panel monitor option VIDEO BNC Jack Composite Video monitor * DTMF is not available for units manufactured after 10/22/2007. ** When LNB DC is supplied on RF center pins, this header is not included. When four RF inputs are supplied without this header, LNB DC is supplied on the center pin of Port 4. Note that COMPEL network can lock LNB DC to OFF. *** After plugging in headphones, the unit immediately displays a screen prompting the user to select the Audio Port to be monitored. Connector Designation Type Pin Signal Description LCD push buttons LED indicators

QUICK START GUIDE

6 800032-02 Rev. G www.wegener.com LED Indicators Eight light-emitting diodes (LEDs) provide status information about your Unity 4600 and its processes as listed in Table 2. Table 2: Unity 4600 LED Indicators Indicator Color and State Description CARRIER GREEN constant Unit has demod and FEC lock on the RF carrier Off Unit does not have demod and FEC lock on the RF carrier TRANSPORT GREEN constant Unit recognizes a valid transport stream Off Unit does not recognize a valid transport stream COMPEL GREEN constant COMPEL control stream received within last two minutes (including keep-alives) while locked continuously on the current transport stream for >2 minutes GREEN flash Unit has had a verified transport stream for >2 minutes and COMPEL is required but no valid COMPEL GREEN flutter COMPEL has been addressed to unit within last 5 seconds (excluding keep-alives). Off Otherwise. Note that this LED must be OFF when there is no valid Transport stream OR COMPEL SERVICES GREEN constant Unit is processing services for delivery. Off Unit is not processing services. WARNING YELLOW constant One or more warning indications present - usually indicates a problem with the incoming signal, a minor unit fault, a possible impending failure, or that important information is available Off No warning conditions CUE GREEN constant A user cue relay is closed (energized). GREEN flutter During a user relay "pulse" activation on any relay Off All user cue relays are open (de-energized) ALARM RED constant One or more current alarm indications RED blink An alarm event has occurred in the past and has not been acknowledged and cleared by the user. Note that the alarm LED may also blink while on. Off No current alarm condition exists AUTH GREEN constant Unit has transport MPEG sync and the stream is not scrambled (in the clear). Streams that are "clear" are always presumed to be "authorized" -- OR -- Unit is authorized for current scrambled transport stream (or selected program) and has transport MPEG sync. When using Wegener CA ('97 Version), being "authorized" means being addressed with current and valid ciphered keystream messages. In a PIN system, if the transport stream is scrambled, and the unit has been programmed with any key other than the null '00000', then it presumes that it is "authorized". Off Unit has transport sync, the transport stream is scrambled, and the unit is NOT authorized. Also OFF if no transport sync.

QUICK START GUIDE

www.wegener.com 800032-02 Rev. G 7 Warranty The following warranty applies to all Wegener Communications products: Technical Support In the event that the unit fails to perform as described, contact Wegener Communications Customer Service at: � Phone: (770) 814-4057 � Fax: (678) 624-0294 � E-mail: [email protected] All Wegener Communications products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Wegener Communications' obligation under this warranty is limited to repairing or, at Wegener Communications' option, replacing parts, subassemblies, or entire assemblies. Wegener Communications shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment, which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs shall be prepaid by the customer. There are no other warranties, express or implied, except as stated herein. Corporate Office: Service Department: WEGENER WEGENER Technology Park / John's Creek Customer Service 11350 Technology Circle 359 Curie Drive Duluth, GA 30097 Alpharetta, GA 30005

Other Receiver Manuals