HP StorageWorks Disk Array XP
operating system configuration guide
Novell Netware
XP12000
XP10000
XP1024
XP128
This guide describes the requirements and procedures for connecting the XP family of disk arrays to a
Novell system and configuring the disk array for operation with the Novell Netware operating system.
Part number: A5951–96053
Fifth edition: November, 2005
Legal and notice information
© Copyright 2003-2005 Hewlett-Packard Development Company, L.P.
Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with
FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical
Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license.
The information contained herein is subject to change without notice. The only warranties for HP products
and services are set forth in the express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical
or editorial errors or omissions contained herein.
Microsoft, Windows, Windows XP, and Windows NT are U.S. registered trademarks of Microsoft Corporation.
Java is a US trademark of Sun Microsystems, Inc.
HP StorageWorks Disk Array XP operating system configuration guide Novell
Netware
About this guide
. . . . . . . . . . . . . . . . . . . . .
5
Intended audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
Disk arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
Related documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
Document conventions and symbols
. . . . . . . . . . . . . . . . . . . . . . .
6
HP technical support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
Subscription service
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
Other HP web sites
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
1 Installation . . . . . . . . . . . . . . . . . . . . . . .
9
Features and requirements
. . . . . . . . . . . . . . . . . . . . . . . . . . .
9
Fibre Channel interface . . . . . . . . . . . . . . . . . . . . . . . . . .
10
Device emulation types . . . . . . . . . . . . . . . . . . . . . . . . . .
10
Failover
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10
I/O path failover
. . . . . . . . . . . . . . . . . . . . . . . . . .
11
SNMP configuration
. . . . . . . . . . . . . . . . . . . . . . . . . . .
11
Installation procedures
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
Install and configure the disk array . . . . . . . . . . . . . . . . . . . . . . .
12
Setting the host mode for the disk array ports
. . . . . . . . . . . . . . . .
13
Setting the System Option Mode . . . . . . . . . . . . . . . . . . . . . .
14
Configuring the Fibre Channel ports
. . . . . . . . . . . . . . . . . . . .
14
Fibre Address . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15
Fabric and connection parameter settings . . . . . . . . . . . . . . . .
15
Install and configure the host
. . . . . . . . . . . . . . . . . . . . . . . . .
16
Loading the OS and software
. . . . . . . . . . . . . . . . . . . . . . .
16
Installing and configuring the HBAs . . . . . . . . . . . . . . . . . . . . .
16
NetWare Client settings
. . . . . . . . . . . . . . . . . . . . . . . . .
17
NetWare ConsoleOne settings . . . . . . . . . . . . . . . . . . . . . . .
17
Fabric zoning and LUN security
. . . . . . . . . . . . . . . . . . . . . .
17
Multiple operating systems in a shared switch fabric
. . . . . . . . . . . . .
18
Connect the disk array to the NetWare server
. . . . . . . . . . . . . . . . . .
19
Defining the paths . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
Verifying new device recognition . . . . . . . . . . . . . . . . . . . . . .
20
Configure disk devices
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
Creating the disk partitions
. . . . . . . . . . . . . . . . . . . . . . . .
21
Assigning the new devices to volumes . . . . . . . . . . . . . . . . . . . .
23
Mounting the new volumes
. . . . . . . . . . . . . . . . . . . . . . . .
25
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
3
Verifying client operations . . . . . . . . . . . . . . . . . . . . . . . . .
26
2 Middleware configuration
. . . . . . . . . . . . . . .
27
Host failover
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
Multipath failover
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
Helpful Multipath commands
. . . . . . . . . . . . . . . . . . . . .
28
MM Set failover priority =
. . . . . . . . .
28
MM Set failover state =
. . . . . . . .
29
MM Set failover path
. . . . . . . . . . . . . . . . . . . .
29
MM Restore failover path device_id
. . . . . . . . . . . . . . . . . .
29
MM Reset failover registry . . . . . . . . . . . . . . . . . . . . . . .
29
Configuring NetWare 6.x Servers for Cluster Services . . . . . . . . . . . . .
29
Install Cluster Services
. . . . . . . . . . . . . . . . . . . . . . . .
30
Create logical volumes . . . . . . . . . . . . . . . . . . . . . . . .
31
3 Troubleshooting . . . . . . . . . . . . . . . . . . . .
33
Error conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33
Calling the HP support center
. . . . . . . . . . . . . . . . . . . . . . . . .
35
Contact information
. . . . . . . . . . . . . . . . . . . . . . . . . . .
35
Before you call
. . . . . . . . . . . . . . . . . . . . . . . . . . .
35
A Path worksheet
. . . . . . . . . . . . . . . . . . . .
37
B Disk array supported emulations . . . . . . . . . . . . .
39
Supported emulations
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
Emulation specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . .
40
Glossary . . . . . . . . . . . . . . . . . . . . . . . .
43
Index
. . . . . . . . . . . . . . . . . . . . . . . . .
47
4
About this guide
This guide provides information about:
•
Requirements and procedures for connecting an XP disk array to a Netware
system
•
Configuring the disk array for use with the Novell NetWare operating system
Intended audience
This guide is intended for system administrators with knowledge of:
•
the host server
•
Novell Netware operating system
•
XP disk arrays
Disk arrays
Unless otherwise noted, the term “disk array” refers to these disk arrays:
•
HP StorageWorks Disk Array XP128
•
HP StorageWorks Disk Array XP1024
•
HP StorageWorks XP10000 Disk Array
•
HP StorageWorks XP12000 Disk Array
Related documentation
The following documents provide related information:
•
HP StorageWorks Disk Array XP128: Owner’s Guide
•
HP StorageWorks Disk Array XP1024: Owner’s Guide
•
HP StorageWorks XP10000 Disk Array: Owner’s Guide
•
HP StorageWorks XP12000 Disk Array: Owner’s Guide
You can find these documents on the storage web site:
http://h18006.www1.hp.com/storage/xparrays.html
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
5
Document conventions and symbols
Convention
Element
Blue text
Cross-reference links and email addresses
Bold
•
Keys that are pressed
•
Text typed into a GUI element, such as a box
•
GUI elements that are clicked or selected, such as
menu and list items, buttons, tabs, and check boxes
•
Literal values typed exactly as shown
Italics
Text emphasis and book titles
Blue, underlined:
www.hp.com [http://
www.hp.com]
Web site addresses
Monospace font
•
File and directory names
•
System output
•
Code
•
Commands, their arguments, and argument values
Monospace, italic
font
•
Code variables
•
Command variables
Monospace, bold
font
Emphasized monospace text
WARNING!
Indicates that failure to follow directions could result in bodily harm or death.
CAUTION:
Indicates that failure to follow directions could result in damage to equipment or data.
NOTE:
Provides additional information.
6
About this guide
HP technical support
In North America, call technical support at 1-800-633-3600, available 24 hours a
day, 7 days a week.
Outside North America, call technical support at the location nearest you. Telephone
numbers for worldwide technical support are listed on the HP support web site:
http://www.hp.com/support. From this web site, select your country.
Collect the following information before calling:
•
Technical support registration number (if applicable)
•
Product serial numbers
•
Product model names and numbers
•
Applicable error messages
•
Operating system type and revision level
•
Detailed questions
For continuous quality improvement, calls may be recorded or monitored.
Subscription service
HP strongly recommends that customers register online using the Subscriber’s Choice
web site: http://www.hp.com/go/e-updates.
Subscribing to this service provides you with e-mail updates about the latest product
enhancements, driver versions, and firmware documents, plus instant access to many
other product resources.
After subscribing, locate your products by selecting Business support and then Storage
under Product Category.
Other HP web sites
For additional information, see the following HP web sites:
•
http://www.hp.com/go/storage
•
http://www.hp.com/support/
•
http://www.hp.com/service_locator
•
http://www.docs.hp.com
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
7
You and your HP service representative each play a role in installation. Your HP service
representative is responsible for installing the disk array and formatting the disk devices.
You are responsible for configuring the host server for the new devices with assistance
from your HP service representative.
Features and requirements
Ask your HP service representative about the latest supported hardware and software.
The disk array has the following features:
•
Storage capacity. The storage capacity for each model is listed below:
XP128: From 8 to 128 drives for up to 36 TB, 48 FC ports
XP1024: From 8 to 1024 drives for up to 149 TB, 64 FC ports
XP10000: Up to 240 drives for up to 69.2 TB, 48 FC ports
XP12000: Up to 1152 drives for up to 332 TB, 128 FC ports
•
Server support. Novell NetWare server
•
Operating system support. Novell NetWare server operating system version 5.x,
or 6.x (FC) with current OS patches.
Before installing the disk array, ensure the environment conforms to these requirements::
•
Host Bus Adapters (HBAs) Install HBAs and all utilities and drivers. Refer to the
adapter documentation for installation details.
•
(Recommended) HP StorageWorks Remote Web Console XP, Command View
XP Advanced Edition or Command View XP with LUN management feature for
configuring disk array ports and paths
•
(Recommended) HP StorageWorks LUN Configuration and Security Manager XP
•
(Optional) Other available XP software (some may not be supported by your
array:
HP StorageWorks Business Copy XP
HP StorageWorks Continuous Access XP
HP StorageWorks Continuous Access Extension XP
HP StorageWorks Auto LUN XP
HP StorageWorks Data Exchange XP
HP StorageWorks Resource Manager XP
HP StorageWorks RAID Manager XP
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
9
HP StorageWorks Cache LUN XP
HP StorageWorks Auto Path XP
HP StorageWorks Cluster Extension XP
HP StorageWorks Performance Advisor XP
Fibre Channel interface
The XP family of disk arrays supports these Fibre Channel elements:
•
Connection speed of 1 Gbps and 2 Gbps
•
Short-wave non-OFC (open fiber control) optical interface
•
Multimode optical cables with SC or LC connectors
•
Public or private arbitrated loop (FC-AL) or direct fabric attach
•
Fibre Channel switches
Even though the interface is Fibre Channel, this guide uses the term “SCSI disk” because
disk array devices are defined to the host as SCSI disks.
Device emulation types
The XP family of disk arrays supports these device emulation types:
•
OPEN-x devices: OPEN-x logical units represent disk devices. Except for
OPEN-V, these devices are based on fixed sizes. OPEN-V is a user-defined size.
Supported emulations include OPEN-3, OPEN-8, OPEN-9, OPEN-E, OPEN-L,
and OPEN-V devices.
•
LUSE devices (OPEN-x*n): Logical Unit Size Expansion (LUSE) devices combine 2
to 36 OPEN-x devices to create expanded LDEVs larger than standard OPEN-x
disk devices. For example, an OPEN-x LUSE volume created from ten OPEN-x
volumes is designated as OPEN-x*10.
•
CVS devices (OPEN-x CVS): Volume Size Configuration (VSC) defines custom
volumes (CVS) that are smaller than normal fixed-sized logical disk devices
(volumes). (OPEN-V is a CVS-based custom disk size that you determine. OPEN-L
does not support CVS.)
•
LUSE (expanded) CVS devices (OPEN-x*n CVS): LUSE CVS combines CVS devices
to create an expanded device. This is done by first creating CVS custom-sized
devices and then using LUSE to combine from 2 to 36 CVS devices. For example,
if three OPEN-9 CVS volumes are combined to create an expanded device, this
device is designated as OPEN-9*3-CVS.
Failover
The XP family of disk arrays supports many standard software products that provide host,
application, or I/O path failover and management.
10
Installation
I/O path failover
NetWare multipath failover is supported. Refer to Chapter 2 for configuration details.
SNMP configuration
The XP family of disk arrays supports standard Simple Network Management Protocol
(SNMP) for remotely managing the disk array. The SNMP agent on the service processor
(SVP) performs error reporting operations requested by the SNMP manager. SNMP
properties are usually set from the SVP but they can also be set remotely using Remote
Web Console XP, Command View XP, or Command View XP Advanced Edition. Refer to
the applicable user’s guide for procedures.
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
11
Perform these actions to install and configure the disk array:
1.
Install and configure the disk array
•
Setting the host mode for the disk array ports
•
Setting the System Option Mode
•
Configuring the Fibre Channel ports
2.
Install and configure the host
•
Loading the OS and software
•
Installing and configuring the HBAs
•
NetWare Client settings
•
NetWare ConsoleOne settings
•
Fabric zoning and LUN security
•
Multiple operating systems in a shared switch fabric
3.
Connect the disk array to the NetWare server
•
Defining the paths
•
Verifying new device recognition
4.
Configure disk devices
•
Creating the disk partitions
•
Assigning the new devices to volumes
•
Mounting the new volumes
•
Verifying client operations
Install and configure the disk array
The HP service representative performs these tasks:
•
Assembling hardware and installing software
•
Loading the microcode updates
•
Installing and formatting devices
After these tasks are finished, use Remote Web Console, Command View, Command
View XP Advanced Edition, or LUN Configuration and Security Manager to complete
the remaining tasks listed below. If you do not have these programs, your HP service
representative can perform these tasks for you.
12
Installation
Setting the host mode for the disk array ports
After the disk array is installed, you must set the host mode for each disk array port to
match the host OS. Set the host mode using LUN Manager in Remote Web Console XP
(shown), Command View XP, or Command View XP Advanced Edition. If these are not
available, the HP service representative can set the host mode using the SVP.
The host mode setting for Novell Netware is OA. The host modes must be set for certain
middleware environments (for example, Novell High Availability Server, NHAS, System
Fault Tolerance, SFT III).
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
13
For the XP1024/XP128 arrays, the host mode can also be set at the port information
window in Command View XP AE.
Setting the System Option Mode
The HP service representative sets the System Option Mode, based on the software
configuration of the host.
Configuring the Fibre Channel ports
Configure the disk array Fibre Channel ports by using Remote Web Console (shown),
Command View, or Command View XP AE. Select the settings for each port based on
your storage area network topology. Use switch zoning if you connect different types of
hosts to the array through the same switch.
14
Installation
In fabric environments, the port addresses are assigned automatically. In arbitrated
loop environments, set the port addresses by selecting a unique arbitrated loop
physical address (AL-PA) or loop ID for each port. For specific values, refer to the HP
StorageWorks LUN Configuration and Security Manager XP User Guide applicable
to your array.
Fabric and connection parameter settings
When configuring the disk array, use LUN Manager in Remote Web Console XP,
Command View XP, or Command View XP Advanced Edition to specify whether the hosts
and the disk array are connected by a fabric switch. Also, you must specify FC-AL or
point-to-point in the “Mode” field of the Change Port Mode pane. The default is FC-AL.
If you are using a fabric switch, consult the switch’s documentation to determine whether
FC-AL or point-to-point should be used. Some fabric switches require that you specify
point-to-point to get the system running.
For detailed topology information, refer to the HP StorageWorks SAN Design Reference
Guide on the www.hp.com
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
15
Install and configure the host
This section explains how to install and configure the host and host bus adapters (HBAs)
that connect the host to the disk array.
Loading the OS and software
Follow the manufacturer’s instructions to load the operating system and software onto
the host. Load all OS patches and configuration utilities supported by HP and the HBA
manufacturer.
Installing and configuring the HBAs
Install and configure the host bus adapters using the HBA manufacturer’s instructions.
HP supplies driver, firmware, and BIOS downloads for commonly available HBAs. These
downloads contain HBA settings that are tested and approved by HP. To obtain a
download, log onto the HP website at www.hp.com and search for the model name or
number of your HBA. Download the file, and follow the installation instructions in the
“readme” or documentation file supplied with each download.
16
Installation
NetWare Client settings
NetWare 6.x
NetWare Client software is required for the client system. After installing the software on
the NetWare server, follow these steps:
1.
Open the Novell Client Configuration dialog and click the Advanced Settings tab.
2.
Change the following parameters:
Give up on Requests to Sas: 180 Net Status Busy Timeout: 90
NetWare ConsoleOne settings
NetWare 6.x
Novell NetWare v6.x requires a tool called ConsoleOne to work in a storage
environment. ConsoleOne is a free Java utility used to manage network resources.
Configure ConsoleOne as follows:
1.
Ensure NetWare Client software is already installed.
2.
Install ConsoleOne on the NetWare 6.x server.
3.
From the NetWare Client, run ConsoleOne:
z:public/mgmt/consoleOne/1.2/bin/ConsoleOne
4.
Right click the Server icon, and select “Disk Management Devices.”
5.
Scroll left to the Media tab.
6.
Click Partitions, New, and select a device.
7.
Click Create, click NSS pools, click New, and name the pool. The pool name and
volume name can be the same.
8.
Click Create, click NSS Logical Volume, select New, name the volume, then select
the pool.
9.
Select Allow volume quota to grow to pool size.
10. Leave the default settings on the next page and click Finish.
Fabric zoning and LUN security
If you plan to use clustering, install and configure the clustering software on the servers.
Clustering is the organization of multiple servers into groups. Within a cluster, each
server is a node. Multiple clusters compose a multi-cluster environment. The following
example shows a multi-cluster environment with three clusters, each containing two
nodes. The nodes share access to the disk array.
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
17
Within the Storage Area Network (SAN), the clusters must be homogeneous (all the same
operating system). Heterogeneous (mixed operating systems) clusters are not allowed.
How you configure LUN security and fabric zoning depends on the SAN configuration.
Multiple operating systems in a shared switch fabric
You can connect multiple clusters with multiple operating systems to the same switch and
fabric using appropriate zoning and LUN security. Note:
•
Storage port zones may overlap if more than one operating system needs to
share an array port.
•
Heterogeneous operating systems may share an XP array port if you set the
appropriate host group and mode. All others must connect to a dedicated XP
array port.
•
Use Secure Manager for LUN isolation when multiple hosts connect through a
shared array port. Secure Manager provides LUN security by allowing you to
restrict which LUNs each host can access.
18
Installation
single OS type
present in the SAN)
Not required
Standalone SAN
(non-clustered)
heterogeneous (more
than one OS type
present in the SAN)
Required
Must be used
when multiple hosts
connect through a
shared port
homogeneous (a
single OS type
present in the SAN)
Not required
Clustered SAN
heterogeneous (more
than one OS type
present in the SAN)
Required
Must be used when
multiple cluster
nodes connect
through a shared
port
homogeneous (a
single OS type
present in the SAN)
Not required
Multi-Cluster SAN
heterogeneous (more
than one OS type
present in the SAN)
Required
Must be used when
multiple cluster
nodes connect
through a shared
port
Connect the disk array to the NetWare server
The HP service representative connects the disk array to the host by:
1.
Verifying operational status of the disk array channel adapters, LDEVs, and paths.
2.
Connecting the Fibre Channel cables between the disk array and the fabric switch
or host.
3.
Verifying the ready status of the disk array and peripherals.
Defining the paths
Use Remote Web Console (shown), Command View, or Command View XP AE to define
paths (LUNs) between hosts and volumes in the disk array.
This process is also called “LUN mapping.” In Remote Web Console and Command
View, LUN mapping includes:
•
Configuring ports
•
Enabling LUN security on the ports
•
Creating host groups
•
Assigning host bus adapter WWNs to host groups
•
Mapping volumes to host groups (by assigning LUNs)
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
19
In Command View XP AE, LUN mapping includes:
•
Configuring ports
•
Creating storage groups
•
Mapping volumes and WWN/host access permissions to the storage groups
For details see LUN Configuration and Security Manager User’s Guide or Command
View XP Advanced Edition Device Manager Web Client User’s Guide. Note the LUNS
and their ports, WWNs, nicknames, and LDEVs for later use in verifying host and
device configuration.
Verifying new device recognition
To verify that the NetWare system recognizes the new disk array devices:
1.
In the NetWare directory, enter SERVER to get to the server console.
2.
At the server console, enter LIST DEVICES to display all devices. Use the Pause
key as needed. The device number (for example, 0x000B) and device type are
displayed for each device:
20
Installation
1. 0x000B: [V6E0-A2-D7D:0] HP OPEN-3 rev:0111
2. 0x000C: [V6E0-A2-D7D:1] HP OPEN-3 rev:0111
:
:
3.
Record the device number for each new device on the worksheet in Appendix A,
Path Worksheet. This information will be useful later during disk partitioning and
volume creation.
4.
Verify that all new disk devices are listed.
Configure disk devices
Configure the disks in the disk array using the same procedure for configuring any new
disk on the host. This includes the following procedures:
1.
Creating the disk partitions
2.
Assigning the new devices to volumes
3.
Mounting the new volumes
4.
Verifying client operations
Creating scripts to configure all devices at once may save you considerable time.
Creating the disk partitions
Before you create the disk partitions, consult the Novell documentation for confirmation
about the type of partition that is available with your operating system version.
NetWare 5.x
1.
At the server console enter LOAD INSTALL to load the Installation Option module.
2.
On the Installation Option screen, click Standard disk options and press ENTER to
access the NetWare disk options.
3.
On the Available Disk Options screen, select Modify disk partitions and Hot Fix
and press ENTER.
4.
The Available Disk Drives screen lists the devices by device number. Record the
device numbers. On the Available Disk Drives screen, select the device to be
partitioned and press ENTER.
5.
If the partition table has already been initialized, skip this step. If the partition table
has not yet been initialized, the partition table message is displayed. Press ENTER to
confirm the message. When the “Initialize the partition table?” message appears,
select Yes and press ENTER to initialize the partition table.
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
21
On the Disk Partition Options screen, select Create NetWare disk partition, and
press ENTER.
7.
You are now prompted to create the partition either automatically or manually. Click
the desired option, and press ENTER.
If you select automatic partitioning, NetWare will create the disk partition and hot
fix area using the available disk space (the hot fix area will be approximately two
percent of the partition size). If you select manual partitioning, enter a partition
size and hot fix area.
8.
On the Disk Partition Information screen, verify (or enter) the partition size and hot
fix data area size, and press F10 to save the changes. You are returned to the
Disk Partition Options screen.
9.
Click Create NetWare disk partition again, and press ENTER.
10. When the “Create NetWare Partition?” message appears, click Yes and press
ENTER to create the specified disk partition on the selected device.
11. Press Esc until you are returned to the Available Disk Drives screen. Repeat steps 4
through 10 to create the disk partition on each new OPEN-x and LUSE device.
12. When you are finished creating disk partitions, return to the Installation Option
screen. From the Available Disk Drives screen, press Esc to return to Available Disk
Options, and then click Return to previous menu and press ENTER.
NetWare 6.0
1.
Start ConsoleOne on the Windows server.
2.
Select the targeted server, right click, and click Properties.
3.
Click the Media tab, click Devices, and click New.
4.
Select a device where you want to create a partition.
5.
Select “NSS” as the partition type.
6.
Enter the size of the partition in bytes (B), kilobytes (KB), megabytes (MB), or
gigabytes (GB) and click OK.
7.
To reserve space for the Hot Fix error correction feature, select Hot Fix and enter the
amount of space or percentage you want to reserve.
Mirrored partitions must be compatible in data area size. This means the new
partition must be at least the same size or slightly larger than the other partitions in
the group. The physical size (combined data and Hot Fix size) of the partition must
be at least 100 KB larger, but no more than 120 MB larger than the data size of
the existing partitions in the mirror group.
8.
To mirror the partition, select Mirror and select one of the following options:
22
Installation
Create New Mirror. This option means you are making the partition capable
of being part of a mirror group. You do not actually create the group until
you add another mirrored partition to the partition you are creating.
•
Existing Mirror Group. (If you select this option, also select the ID of the
mirrored partition.) This shows a list of existing mirror groups that are
compatible in data area size. This option lets you add this new partition to
one of the mirror groups in the list.
9.
Select a label for the partition (optional).
10. Click OK.
NetWare 6.5
1.
Enter NSSMU at the server console
2.
In the main menu, select “Partitions.”
3.
Press Insert, then select a device where you want to create a partition.
4.
Select “NSS” as the partition type.
5.
Enter the size of the partition in bytes (B), kilobytes (KB), megabytes (MB), or
gigabytes (GB) and click OK.
Assigning the new devices to volumes
A volume can span as many as 32 devices, so you can assign more than one device to
a volume. The addition of new volumes to the NetWare server may require a memory
upgrade. See the NetWare documentation or contact Novell customer support.
NetWare 5.x
1.
On the Installation Option screen, click Volume options and press ENTER to display
the volume options.
The existing volumes are listed by volume name, and the volume options are
displayed at the bottom of the screen.
2.
Execute the “Add/View/Modify volume segments” command by pressing the Ins
or F3 key.
The Segment List of Volume Disk screen displays the existing devices by device
number. The Volume assignment column displays “(free space)” for each device that
is not yet assigned to a volume.
3.
Execute the “Make a volume assignment” command as follows: move the cursor
to the line containing the desired device, then move the cursor onto “(free space)”
in the Volume assignment column, and press ENTER.
4.
When the “What do you want to do with this free segment?” message appears,
select the desired option, and press ENTER. If you selected “Make this segment
part of another volume,” select the volume you want to add this segment to, and
press ENTER.
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
23
In the Disk Segment Parameters screen, enter the new volume name (or verify the
selected volume), and enter the disk segment size. The segment size is the same
as the partition size entered during disk partitioning.
6.
Press ENTER to save the new volume information and return to the Segment List
of Volume Disk screen.
7.
On the Segment List of Volume Disk screen, press F10 to save the new volume
information and return to the volume list.
8.
Repeat the preceding steps until you have assigned all new disk array devices
to volumes. When you are finished assigning new devices to volumes, press Esc
to save your volume changes.
9.
When the confirmation message appears, click Yes and then press ENTER to save
all changes and return to the Installation Option screen.
NetWare 6.0
1.
Using ConsoleOne select the targeted server, right click, and click Properties.
2.
Click the Media tab, then click NSSPools.
3.
Click New, and input the name for the new pool.
4.
Select the disks to be included in the pool.
5.
After you have created the pool, select Activate on Creation and Cluster Enable
on Creation as desired.
6.
Specify the Virtual Server Name, IP Address, Advertising Protocols and, if
necessary, the CIFS Server Name.
7.
Click Finish.
NetWare 6.5
1.
Enter NSSMU at the server console
2.
In the main menu, select Pools.
3.
Press Insert and enter a name for the new pool.
4.
Select Activate on Creation and Cluster Enable on Creation as desired.
5.
Specify the Virtual Server Name, IP Address, Advertising Protocols and, if
necessary, the CIFS Server Name.
6.
Select Create.
24
Installation
Mounting the new volumes
NetWare 5.x
1.
From the Installation Option screen, click Volume options to display the volume
list and volume options, and then click Mount/Dismount an existing volume and
press ENTER.
2.
On the Directory Services Login/Authentication screen, enter the NetWare
administrator password, then press ENTER.
3.
An informational message displays the number of new volumes just added. Press
ENTER to continue.
4.
You are now prompted to select the desired mount action. Click either Mount all
volumes or Mount volumes selectively as desired.
The mount status for all volumes is now displayed.
5.
If you chose to mount volumes selectively, select the desired volume, press ENTER to
mount the volume, and then confirm that the volume’s status changed to MOUNTED.
Repeat this step for each new volume to confirm that all new volumes can be
mounted successfully.
6.
When you have confirmed that all new volumes/devices were mounted successfully,
you are finished with disk array device configuration. Leave the new volumes
mounted for now, so you can verify that NetWare clients can access the new
volumes.
NetWare 6.0
1.
Using ConsoleOne select the targeted server, right click, and click Properties.
2.
Click the Media tab, and click NSS Logical Volumes.
3.
Click New, enter a name for the volume, then click Next.
4.
In the Create Logical Volume - Storage Information window, select the desired
pool/device, enter the desired Volume Quota, then click Next.
5.
In the Create Logical Volume - Storage Information window check Activate and
Mount in the “On Creation” box, then click Finish.
6.
Confirm that the logical volume has been created.
7.
Map the created Logical Volume as the Network Drive.
8.
Confirm the mapped drive.
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
25
Enter NSSMU at the server console.
2.
In the main menu, select Volumes.
3.
Press Insert and enter a name for the new volume, then click Next.
4.
Select the desired pool/device, enter the desired Volume Quota, then click Next.
5.
Review and change volume attributes as necessary.
6.
Select Create.
Verifying client operations
After configuring the Novell NetWare system, verify that NetWare clients can access the
new volumes. To verify access:
1.
Copy an existing file onto each new volume.
2.
Verify that the file was copied successfully.
26
Installation
2 Middleware configuration
The disk array supports many industry-standard middleware products which provide host
failover and logical volume management. Available host failover products for the Novell
NetWare server operating system include the Novell High Availability Server (NHAS),
SFT III software products, Novell Clustering Services, and Novell Multipath Support.
Logical volume management functions are included in the Novell NetWare server
operating system (for example, Installation Option NetWare Loadable Module,
NWAdmin).
Host failover
The NHAS and SFT III software products provide hardware fault tolerance (that is, host
failover capability) for the Novell NetWare environment.
Novell Clustering Service provides fault tolerance by moving (failing over) server
resources from one server to another.
If you plan to use these products with the disk array, contact your HP service
representative for the latest information about support and configuration requirements.
For assistance with NHAS or SFT III operations, see the Novell user documentation, or
contact Novell customer support.
Multipath failover
The XP disk arrays support NetWare multipath failover. If multiple HBAs are connected
to the disk array with commonly-shared LUNs, you can configure path failover to
recognize each new device path:
1.
In the startup.cfg file, enter
SET MULTI-PATH SUPPORT=ON
LOAD SCSIHD.CDM AEN
2.
If the line LOAD CPQSHD.CDM is present it should be commented out.
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
27
SET MULTI-PATH SUPPORT=ON
LOAD ACPIDRV.PSM
######## End PSM Drivers ########
LOAD SCSIHD.CDM AEN
#LOAD CPQSHD.CDM
LOAD IDECD.CDM
######## End CDM Drivers ########
LOAD IDEATA.HAM SLOT=10011
LOAD CPQRAID.HAM SLOT=10019
LOAD QL2300.HAM SLOT=2 /LUNS /ALLPATHS /PORTNAMES/CONSOLE
LOAD QL2300.HAM SLOT=3 /LUNS /ALLPATHS /PORTNAMES /CONSOLE
######## End HAM Drivers ########
3.
Restart the server.
4.
To see a list of the failover devices and paths, at the server prompt enter
LIST FAILOVER DEVICES
Example failover device path listing
0x20 [V6E0-A2-D0:0] HP OPEN-3 rev:HP16
Up 0x0D [V6E0-A2-D0:0] HP OPEN-3 rev:HP16
Priority = 0 selected
Up
0x1B [V6E0-A3-D0:0] HP OPEN-3 rev:HP16
Priority = 0
0x21 [V6E0-A2-D0:2] HP OPEN-3 rev:HP16
Up
0x0F [V6E0-A2-D0:2] HP OPEN-3 rev:HP16
Priority = 0 selected
Up
0x1D [V6E0-A3-D0:2] HP OPEN-3 rev:HP16
Priority = 0
0x22 [V6E0-A2-D0:4] HP OPEN-3 rev:HP16
Up
0x11 [V6E0-A2-D0:4] HP OPEN-3 rev:HP16
Priority = 0 selected
Up
0x1F [V6E0-A3-D0:4] HP OPEN-3 rev:HP16
Priority = 0
0x23 [V6E0-A2-D0:1] HP OPEN-3 rev:HP16
Up
0x0E [V6E0-A2-D0:1] HP OPEN-3 rev:HP16
Priority = 0 selected
Up
0x1C [V6E0-A3-D0:1] HP OPEN-3 rev:HP16
Priority = 0
0x24 [V6E0-A2-D0:1] HP OPEN-3 rev:HP16
Up
0x0E [V6E0-A2-D0:3] HP OPEN-3 rev:HP16
Priority = 0 selected
Up
0x1C [V6E0-A3-D0:3] HP OPEN-3 rev:HP16
Priority = 0
Helpful Multipath commands
Other useful Multipath commands are described below.
MM Set failover priority =
This command sets the priority level for each path. The ID must be a valid path ID, and
the number must be a decimal integer value in the range 1-4,000,000, with 1 being
the highest priority and 4,000,000 being the lowest priority. The default value of 0
(zero) indicates that there is no priority.
The /insert option will move the priorities on all paths that were equal or lower than
. For example, if the paths had priorities of 1,2,3,4, and a new path is
28
Middleware configuration
assigned a number 2 using the /insert option, then the paths that were 2, 3, and 4 are
moved to 3, 4, and 5, and the new path assigned priority 2.
MM Set failover state =
This command sets the state of the path. The ID must be a valid path ID. If the path is Up,
it can be taken offline, and will not be used to switch to. Another path will be selected.
If the path is offline, the path will be reactivated, if possible, and set to an Up state. The
/setpath option will reselect the highest priority path that is up.
MM Set failover path
This command moves the selected path to the one specified by the path ID. The ID
must be a valid path that is up. This does not alter the priorities on the paths, and any
reselection of the path may cause the path to change. A later option will be added to
reassign that path to the highest priority.
MM Restore failover path device_id
This command forces the device to reselect the highest priority path that is online. The
device_id must be a valid device ID.
MM Reset failover registry
This command will delete all the failover entries in the registry, and recreate them again
based on the current set of failover devices.
As a path fails, it is automatically marked as a Down (offline) path, and the next highest
priority path is automatically selected. When the device is reactivated, the state is
automatically reset to an Up (online) state, and again the highest priority path is selected.
Use the NWCONFIG NetWare utility to create partitions/Volumes for each LUN. For
additional information consult these web sites:
http://www.novell.com/documentation/
http://www.support.novell.com
Configuring NetWare 6.x Servers for Cluster Services
The following requirements must be met in order to use clustering:
•
NetWare 6.x on each server in the cluster.
•
All servers must be in the same NDS tree.
•
Cluster Services running on each server in the cluster.
•
All servers must have a connection to the shared disk array.
•
All cluster servers configured with the IP protocol and on the same IP subnet.
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
29
One client running Windows 98 with Novell Client v4.83 or later.
Install Cluster Services
1.
Bring up all servers that will be in the cluster.
2.
Log into a client as Administrator.
3.
Insert the NetWare 6.x CD in the CD drive of the client.
4.
Start Cluster Services installation:
Select Start and Run.
Enter “D: \ NWDEPLOY.EXE” and click OK (where D: points to the CD drive).
Double-click the Post-Installation Tasks folder.
Click Install or Upgrade a Novell Cluster.
Click Next on the NetWare Cluster Services for NetWare 6.0 Installation window.
5.
Create the new cluster:
Select Create New Cluster on the NCS Action window,
Click Next.
Enter a Unique Cluster Object name (for example, Cluster_Object).
Click Browse.
Double-click to open the tree that contains the cluster servers.
Select the server context within the tree (Novell), and click OK.
Click Next.
6.
Add servers to the cluster:
Click Browse.
Highlight all of the servers that you want to add and click Add to Cluster. You may
use the shift and control keys to select multiple nodes.
After all servers in the cluster appear on the list, click Next.
Wait while NWDeploy accesses each node.
After all services have been accessed and added to the “NetWare Servers in
Cluster” list, click OK.
7.
Enter a unique IP address for the Master_IP_Address_Resource (for example,
10.1.1.5) in the Cluster IP Address Selection window and click Next.
8.
Set up the shared media:
Verify that Yes is selected next to “Does the cluster have shared media?”
30
Middleware configuration
Select No next to “... mirror Cluster Partition”, if prompted.
Click Next to accept the default shared media settings, if prompted.
Select Start Clustering on newly added or upgraded servers after installation.
9.
Install the licenses:
Insert the appropriate Cluster License diskette into drive A: of the client.
Click Next.
Click Next to select all available licenses.
Click Next at the summary screen.
10. Click Finish to complete installation. Main file copy starts now.
11. When the installation is complete, click Close.
12. Wait for the Deployment Manager to reappear on the client. Click Cancel, then
click Yes to close the Deployment Manager.
Create logical volumes
NetWare 6.0
1.
Using ConsoleOne, select the targeted server, right click, and click Properties.
2.
Click the Media tab, and click NSS Logical Volumes.
3.
Click New, enter a name for the volume, and click Next.
4.
In the Create Logical Volume - Storage Information window, select the desired
pool/device, enter the desired Volume Quota, then click Next.
5.
In the Create Logical Volume - Storage Information window check Activate and
Mount in the “On Creation” box, then click Finish.
6.
Confirm that the logical volume has been created.
7.
Map the created Logical Volume as the Network Drive.
8.
Confirm the mapped drive.
Netware 6.5
1.
Enter NSSMU at the server console.
2.
In the main menu, select Volumes.
3.
Press Insert and enter a name for the new volume, then click Next.
4.
Select the desired pool/device, enter the desired Volume Quota, then click Next.
5.
Review and change volume attributes as necessary.
6.
Select Create.
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
31
This section includes resolutions for various error conditions you may encounter.
If you are unable to resolve an error condition, ask your HP support representative for
assistance. See Calling the HP support center
Error conditions
Depending on your system configuration, you may be able to view error messages
(R-SIMS) as follows:
•
In Remote Web Console (Status tab)
•
In Command View Advanced Edition (“Alerts” window).
•
In Command View (Event History or Event Notification windows).
Error Condition
Recommended Action
The logical devices are not recognized by
the host.
Verify that the READY indicator lights on the
disk array are ON.
Verify that fiber cables are correctly installed
and firmly connected.
Verify that the target IDs are properly
configured. The LUNs for each TID must
start at 0 and continue sequentially without
skipping any numbers.
Verify that the TIDs/WWNs on each bus
are unique. Do not install two devices with
the same ID on the same bus.
Recheck the buses for new devices.
Verify that LUSE devices are not intermixed
with normal LUNs on the same port.
Verify that the maximum number of LUSE
devices per port has not been exceeded.
Verify that the disk array host mode is set
correctly.
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
33
The host does not reboot properly after hard
shutdown.
If you power off the host without executing
the shutdown process, wait three minutes
to allow the disk array’s internal timeout
process to purge queued commands. If
the host restarts while the disk array is
processing queued commands, the host may
not reboot successfully.
Physical volumes cannot be created.
Verify that the disk array logical devices are
correctly formatted.
Logical volumes cannot be created.
Verify that the volume capacity for OPEN-x
volumes is not greater than the maximum
capacity allowed. See the Emulation
specifications table.
Verify that the capacity of the volume group
is not less than the total capacity of the
partitioned logical volume.
A file system is not mounted after rebooting.
Verify that the host was restarted correctly.
Verify that the file system attributes are
correct.
The disk array performs a self reboot
because the disk array was busy or it
logged a panic message.
Reboot the host.
The disk array responds “Not Ready” or the
disk array has displayed “Not Ready” and
timed out.
Contact HP.
The host detects a parity error.
Check the HBA and make sure it was
installed properly.
Reboot the host.
The host hangs or devices are declared and
the host hangs.
Make sure there are no duplicate disk array
TIDs and that disk array TIDs do not conflict
with any host TIDs.
Verify server hardware configuration.
Ethernet card may need to be in slot 9 for
NetWare to function with the HP Netserver.
Avoid shared interrupts; if unavoidable,
use sharing among similar card types.
Check for the latest device drivers and try
simplifying the configuration.
34
Troubleshooting
Calling the HP support center
If you are unable to resolve an error condition, contact the HP support center for
assistance.
Contact information
In North America, call technical support at 1-800-633-3600, available 24 hours a
day, 7 days a week.
Outside North America, call technical support at the location nearest you. Telephone
numbers for worldwide technical support are listed on the HP support web site:
http://www.hp.com/support. From this web site, select your country.
Before you call
Be sure to have the following information available:
•
Technical support registration number (if applicable)
•
Product serial numbers
•
Product model names and numbers
•
Applicable error messages
•
Operating system type and revision level
•
Detailed, specific questions
For continuous quality improvement, calls may be recorded or monitored.
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
35
A Path worksheet
LDEV (CU:LDEV) (CU =
control unit)
Device
Type
SCSI Bus
Number
Path 1
Alternate Paths
0:00
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:01
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:02
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:03
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:04
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:05
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:06
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:07
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:08
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:09
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:10
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:11
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:12
TID:
LUN:
TID:
LUN:
TID:
LUN:
0:13
TID:
LUN:
TID:
LUN:
TID:
LUN:
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
37
B Disk array supported
emulations
This appendix provides information about supported emulations and emulation
specifications. Some parameters may not be relevant to your array. Consult your HP
representative for information about supported configurations for your system.
Supported emulations
XP Model
Emulation
Emulation
Supported
LUSE
CVS
LUSE & CVS
OPEN-3
Yes
Yes
Yes
Yes
OPEN-8
Yes
Yes
Yes
Yes
XP128
OPEN-9
Yes
Yes
Yes
Yes
XP1024
OPEN-E
Yes
Yes
Yes
Yes
XP10000
OPEN-K
XP12000
OPEN-L
Yes
Yes
OPEN-M
OPEN-V
Yes
Yes
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
39
MB* (Note 3)
OPEN-3
SCSI disk
4806720
512
3338
15
96
2347
OPEN-8
SCSI disk
14351040
512
9966
15
96
7007
OPEN-9
SCSI disk
14423040
512
10016
15
96
7042
OPEN-E
SCSI disk
28452960
512
19759
15
96
13893
OPEN-L
SCSI disk
71192160
512
49439
15
96
34761
OPEN-V
SCSI disk
max=125827200
512
Note 5
15
128
Note 6
LUSE
OPEN-3*n
SCSI disk
4806720*n
512
3338*n
15
96
2347*n
OPEN-8*n
SCSI disk
14351040*n
512
9966*n
15
96
7007*n
OPEN-9*n
SCSI disk
14423040*n
512
10016*n
15
96
7042*n
OPEN-E*n
SCSI disk
28452960*n
512
19759*n
15
96
13893*n
OPEN-L*n
SCSI disk
71192160*n
512
49439*n
15
96
34761*n
OPEN-V*n
SCSI disk
max=125827200
Note 4
512
Note 5
15
128
Note 6
CVS
OPEN-3 CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-8 CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-9 CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-E CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
CVS LUSE
OPEN-3*n CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-8*n CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-9*n CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-E*n CVS
SCSI disk
Note 4
512
Note 5
15
96
Note 6
OPEN-V*n
SCSI disk
Note 4
512
Note 5
15
128
Note 6
*Capacity = (512 x number of blocks) ÷ 10242
40
Disk array supported emulations
The availability of a disk type depends on the disk array.
Note 2:
The devices are defined to the host as SCSI disk devices, even though the interface is
Fibre Channel.
Note 3:
The device capacity can sometimes be changed by the BIOS or host adapter board.
This may make actual capacity different from that listed in the table.
Note 4:
The number of blocks for a CVS volume is calculated as follows:
# of blocks = (# of cylinders) × (# of heads) × (# of sectors per track)
Example
For an OPEN-3 CVS volume with capacity = 37 MB:
# of blocks = (53 cylinders–see Note 5) × (15 heads) ×
(96 sectors per track) = 76320
Example
For an OPEN-V CVS volume with capacity = 49 MB:
# of blocks = (53 cylinders–see Note 5) × (15 heads) ×
(128 sectors per track) = 101760
Note 5:
The number of cylinders for a CVS volume is calculated as follows (↑…↑means that the
value should be rounded up to the next integer):
OPEN-3/8/9/E: The number of cylinders for a CVS volume = # of cylinders = ↑
(capacity (MB) specified by user) × 1024/720 ↑
Example
For an OPEN-3 CVS volume with capacity = 37 MB:
# of cylinders = ↑37 × 1024/720↑= ↑52.62↑
(rounded up to next integer) = 53 cylinders
OPEN-V: The number of cylinders for a CVS volume = # of cylinders = ↑(capacity
(MB) specified by user) × 16/15 ↑
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
41
For an OPEN-V CVS volume with capacity = 49 MB:
# of cylinders = ↑49 × 16/15↑= ↑52.26↑
(rounded up to next integer) = 53 cylinders
OPEN-3/8/9/E: The number of cylinders for a CVS LUSE volume = # of cylinders = ↑
(capacity (MB) specified by user) × 1024/720 ↑× n
Example
For a CVS LUSE volume with capacity = 37 MB and n = 4:
# of cylinders = ↑37 × 1024/720↑× 4 = ↑52.62↑× 4 = 53 × 4 = 212
OPEN-V: The number of cylinders for a CVS LUSE volume = # of cylinders = ↑(capacity
(MB) specified by user) × 16/15 ↑× n
Example
For an OPEN-V CVS LUSE volume with capacity = 49 MB and n = 4:
# of cylinders = ↑49 × 16/15↑× 4 = ↑52.26↑× 4 = 53 × 4 = 212
Note 6:
The capacity of an OPEN-3/8/9/E CVS volume is specified in MB, not number of
cylinders. The capacity of an OPEN-V CVS volume can be specified in MB or number
of cylinders. You set the volume size using Remote Web Console, Command View or
Command View Advanced Edition.
42
Disk array supported emulations
Arbitrated loop physical address.
array group
A group of 4 or 8 physical hard disk drives (HDDs) installed in
an XP disk array and assigned a common RAID level. RAID1
array groups consist of 4 (2D+2D) or 8 HDDs (4D+4D). RAID5
array groups include a parity disk but also consist of 4 (3D+1P)
or 8 HDDs (7D+1P). All RAID6 array groups are made up of
8 HDDs (6D+2P).
BC
HP StorageWorks Business Copy XP. BC lets you maintain up to
nine local copies of logical volumes on the disk array.
CA
HP StorageWorks Continuous Access XP. CA lets you create
and maintain duplicate copies of local logical volumes on a
remote disk array.
Command View
(CVXP)
HP StorageWorks Command View XP, a software product
for managing XP arrays. Command View runs on a
Windows-based management workstation.
Command View
XP Advanced Edi-
tion (CVXP AE)
HP StorageWorks Command View XP Advanced Edition,
installs on the user-provided Device Manager server and
provides a browser-based platform from which you can manage
the XP family of disk arrays—even globally distributed arrays.
command device
A volume on the disk array that accepts Continuous Access
or Business Copy control operations which are then executed
by the disk array.
CU
Control Unit. Contains LDEVs and is approximately equivalent
to SCSI Target ID.
CVS
Custom volume size. CVS devices (OPEN-x CVS) are custom
volumes configured using array management software to
be smaller than normal fixed-size OPEN system volumes.
Synonymous with volume size customization (VSC).
DKC
The array cabinet that houses the channel adapters and service
processor (SVP).
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
43
DKU (disk cabinet
unit)
The array cabinets that house the disk array physical disks.
emulation modes
The logical devices (LDEVs) associated with each RAID group
are assigned an emulation mode that makes them operate like
OPEN system disk drives. The emulation mode determines the
size of an LDEV:
OPEN-3: 2.46 GB
OPEN-8: 7.38 GB
OPEN-9: 7.42 GB
OPEN-E: 13.56 GB
OPEN-L: 36 GB
OPEN-V: User-defined custom size
failover
Disconnecting a failed unit or path and replacing it with an
alternative unit or path in order to continue functioning.
FC
Fibre Channel.
FC-AL
Fibre Channel arbitrated loop.
FCP
Fibre Channel Protocol.
GB
Gigabytes.
HBA
Host bus adapter.
host mode
Each port can be configured for a particular host type. These
modes are represented as two-digit hexadecimal numbers. For
example, host mode 08 represents an HP-UX host.
LDEV
Logical device. An LDEV is created when a RAID group is
carved into pieces according to the selected host emulation
mode (that is, OPEN-3, OPEN-8, OPEN-L). The number of
resulting LDEVs depends on the selected emulation mode. The
term LDEV is often used synonymously with the term volume.
LUN
Logical unit number. A LUN results from mapping a SCSI
logical unit number, port ID, and LDEV ID to a RAID group.
The size of the LUN is determined by the emulation mode of
the LDEV and the number of LDEVs associated with the LUN.
For example, a LUN associated with two OPEN-3 LDEVs has a
size of 4,693 MB.
LUSE
A LUN is normally associated with only a single LDEV. The
LUSE feature allows a LUN to be associated with 1 to 36
LDEVs. Essentially, LUSE makes it possible for applications
to access a single large pool of storage. The LUSE feature
is available when the HP StorageWorks LUN Configuration
Manager product is installed.
44
Glossary
Open Fibre Control.
OPEN-x
A general term describing any one of the supported OPEN
emulation modes (for example, OPEN-L).
OS
Operating system.
PA
Physical address.
path
“Path” and “LUN” are synonymous. Paths are created by
associating a port, a target, and a LUN ID with one or more
LDEVs.
port
A physical connection that allows data to pass between a
host and the disk array. The number of ports on an XP disk
array depends on the number of supported I/O slots and the
number of ports available per I/O adapter. The XP family of
disk arrays supports Fibre Channel (FC) ports as well as other
port types. Ports are named by port group and port letter, such
as CL1-A. CL1 is the group, and A is the port letter.
RAID
Redundant array of independent disks.
remote console PC
The PC running HP StorageWorks Remote Control XP.
Remote Control
(RC)
HP StorageWorks Remote Control XP. A software product used
for managing XP arrays.
Remote Web Con-
sole (RWC)
HP StorageWorks XP Remote Web Console. A browser-based
program installed on the SVP that allows you to configure and
manage the disk array.
R-SIM
Remote service information message.
SCSI
Small computer system interface.
SIM
Service information message.
SNMP
Simple Network Management Protocol.
SVP
Service processor, which is the PC built into the disk controller.
The SVP provides a direct interface into the disk array. SVP use
is reserved for HP support representatives only.
TB
Terabyte.
TID
Target ID.
Volume
On the XP array, a volume is a uniquely identified virtual
storage device composed of a control unit (CU) component
and a logical device (LDEV) component separated by a colon.
For example 00:00 and 01:00 are two uniquely identified
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
45
volumes; one is identified as CU = 00 and LDEV = 00, and
the other as CU = 01 and LDEV = 00; they are two unique
separate virtual storage devices within the XP array.
VSC
Volume size customization. Synonymous with CVS.
WWN
World Wide Name. A unique identifier assigned to a Fibre
Channel device.
46
Glossary
arbitrated-loop physical address, 15
audience, 5
Auto LUN XP, 9
Auto Path XP, 10
B
Business Copy XP, 9
C
Cache LUN XP, 10
client, verifying operations, 26
Cluster Extension XP, 10
clustering, 17, 18, 27, 29
Command View XP Advanced Edition,
9
Command View, 9, 12, 14, 19
Command View XP Advanced Edition,
12, 14, 19
configuration
cluster services, 29
device, 21
emulation types, 10
Fibre Channel ports, 14
HBAs, 16
host, 16
host mode, setting, 13
middleware, 27
port, 14
Continuous Access Extension XP, 9
Continuous Access XP, 9
conventions, document, 6
D
Data Exchange XP, 9
device(s)
assigning to volumes, 23
configuration, 21
emulation types, 10
logical, not recognized by host, 33
recognition, 20
type specifications, 40
verifying, 20
disk array(s)
connecting, 19
features, 9
installation overview, 12
Not Ready error message, 34
operating system versions, 9
requirements, 9
self reboots, 34
server support, 9
storage capacity, 9
support for middleware products, 27
disk, partitions, 21
document conventions, 6
documentation
HP web sites, 5
Novell, 29
related, 5
E
emulation(s)
device emulation types, 10
supported, 40
error conditions, 33
F
fabric environment
parameter settings, 15
port addresses, 15
zoning, 17, 18
failover, 10, 27
host, 27
multi-path, 27
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
47
connection speed, 10
interface, 10
parameter settings, 15
ports, configuring, 14
supported elements, 10
topology example, 15
file system(s)
not mounted after rebooting, 34
G
glossary, 43
H
HBA(s)
installing, 16
multiple with shared LUNs, 27
help, obtaining, 7
host
configuration, 16
doesnxd5 t reboot properly, 34
hangs up, 34
host mode, setting, 13
HP
service representative tasks, 12
storage web site, 7
Subscriber’s Choice web site, 7
technical support, 7, 35
I
installation
connecting disk array, 19
HBAs, 16
HP service representative tasks, 12
overview, 12
interface, Fibre Channel, 10
L
logical volumes, 27
cannot be created, 34
LUN Configuration and Security
Manager XP, 9, 12, 19
LUN(s)
creating, 19
mapping, 19
security, 17, 18
M
middleware
configuration, 27
disk array support, 27
multi-cluster environment, 17
multi-path failover, 27
N
NetWare
client settings, 17
ConsoleOne settings, 17
NHAS, 27
O
operating system(s)
loading, 16
LUN security for, 18
multiple, fabric zoning for, 18
NetWare
client settings, 17
ConsoleOne settings, 17
supported versions, 9
P
parity error, 34
partitions
creating, 21
path(s)
defining, 19
worksheet, 37
Performance Advisor XP, 10
physical volumes, cannot be created,
34
port(s)
address, 15
Fibre Channel, 14
host mode, setting, 13
48
RAID Manager XP, 9
related documentation, 5
Remote Web Console, 9, 12, 14, 19
Resource Manager XP, 9
S
SCSI disk, 10
Secure Manager XP, 18
security, LUN, 17, 18
server
support, 9
SFT III, 27
SNMP configuration, 11
software, optional, 9
storage capacity, 9
Subscriber’s Choice, HP, 7
symbols in text, 6
System Option Mode, 14
T
technical support, 35
HP, 7
Novell, 29
text symbols, 6
topology, fabric, 15
troubleshooting, 33
error conditions, 33
technical support, 35
V
volume(s)
assigning, 23
logical, 27
logical, cannot be created, 34
mounting, 25
physical, cannot be created, 34
W
web sites, 5
HP documentation, 7
HP storage, 7
HP Subscriber’s Choice, 7
websites
Novell documentation, 29
Novell support, 29
worksheet, path, 37
X
XP family
optional software, 9
storage capacity, 9
Z
zoning, fabric, 17, 18
HP StorageWorks Disk Array XP operating system configuration guide Novell Netware
49