Texecom PRESTIGE HD Installation Instructions
Text of the manual
ALTERING COVERAGE AT 2m
MOUNTING HEIGHT
6
ANGLING THE DETECTOR
4
3
STANDARDS & APPROVALS
2
ENVIRONMENTAL
1
PHYSICAL
8m
26'2"
10m
32'9"
15m
50'
15m
50'
2m
6'7"
2m
6'7"
2m
6'7"
2m
6'7"
-35°C (-31°F) to +60°C (+140°F)
150g (5oz) approx.
-35°C (-31°F) to +55°C (+131°F)
60mm
(2.4”)
40mm
(1.6”)
112.25mm
(4.4”)
2.5mm (0.1”) ABS
QUALITY ASSURANCE
WARRANTY
10 year replacement warranty.
The Prestige TD is designed to detect the movement of an intruder and activate
an alarm control panel. As the Prestige TD is not a complete alarm system, but only
a part thereof, Texecom cannot accept responsibility or liability for any damages
whatsoever based on a claim that the Prestige TD failed to function correctly.
Due to our policy of continuous improvement Texecom reserves the right to
change specification without prior notice. All specifications are measured at 20ºC
(68ºF).
© 2003-2006 Texecom Ltd. Document Ref: PTD/EU/1.0-3
The Prestige TD is protected by UK & International Registered Designs. Registered Design No’s: 3004997, 3004260 &
3004261. Prestige is a Trademark of Texecom Ltd.
C e r t i f i c a t e N u m b e r : F M 3 5 2 8 5
Professional Twin Dual PIR
INSTALLATION INSTRUCTIONS
INS 253-3
Quiescent Current =
10mA @ 12VDC
Max Current* =
16mA @ 12VDC
*Maximum current measured at detection/warm up
!
!
0.3 - 3.0m/s
1 - 10ft/s
1
2
3
PULSE COUNT
www.texe.com
Ask your distributor today for the Texecom full colour Product Guide.
JP1
JP1
✗
LED ON
LED OFF
✗
DO NOT TOUCH
3.0m/9’10”
2.5m/8’2”
2.0m/6’7”
1.5m/4’11”
7
MOUNTING HEIGHT AND
SETTINGS
4m
13'1"
15m
50'
2m
6'7"
2m
6'7"
!
✓
5
LATCH INPUT FUNCTIONS
The latch terminal (see Section 4) can perform several different functions
depending on how it is connected:
Latch connected to Set Positive (SW+, Set+): The LEDs will be disabled while
the system is set. Any detectors triggered while the system is set will indicate
this by permanently lighting the alarm LED (upon unsetting the system).
Detectors can be reset by taking the latch line high and then low again.
Latch connected to Alarm Positive (AL+, A+ve): The first detector activated
while the system is set will indicate this with a slowly flashing alarm LED
(upon unsetting the system). Detectors activated subsequently will indicate
this by permanently lighting the alarm LED. Detectors can be reset by taking
the latch line high and then low again.
ALARM
PIR Right
PIR Left
Made In England
EOL Resistor Selection
See Section 14
Detector Standard:
Independently certified to TS 50131-2-2 Grade 2
Environmental Class II.
System Standard:
Suitable for use in a PD 6662/BS EN 50131-1 Grade
2 system. Environmental Class II.
EMC:
Independently certified to EN 50130-4 : 1996.
RF Immunity:
No false alarms from 80MHz to 2GHz at 10V/m.
Complies with BS EN 61000-4-3 : 2002.
Electrostatic
Discharge:
No false alarms up to 8kV.
Complies with BS EN 61000-4-2 : 1995.
Fast Transient
Immunity:
No false alarms up to ±4kV.
Complies with BS EN 61000-4-4 : 1995.
High Energy
Transient Immunity:
No false alarms up to ±2kV. Complies with BS EN
61000-4-5 : 1995.
Conducted RF
Susceptibility:
No false alarms at 10Vrms. Complies with BS EN
61000-4-6 : 1996.
Conducted &
Radiated Emissions:
Complies with EN 55022 Class B.
Product Identifier:
TD
15 DETECTOR KNOCKOUTS
17 WALL MOUNT BRACKET
12 WIRING THE PRESTIGE TD
Do not run cable parallel to mains wiring
11 MOUNTING THE PRESTIGE TD
For indoor use only
10 COVERAGE PATTERN
Volumetric
9
COVERAGE AND PICK-UP
2
2
4
1
3
1
3
4
5
7
5
8
✗
Seal all holes
INS 253-3
See Mounting Height Diagram (Section 7)
6
✓
✓
15m
50’
15m
50’
85º
16 CEILING MOUNT BRACKET
✓
✗
✓
✗
✓
Mount on a stable surface
230V
110V
230V
110V
✓
✗
13 CHOOSING A LOCATION
Avoid common false alarm sources
✗
✗
✗
✗
✗
✗
✗
✗
14 EOL RESISTOR JUMPER LINKS
The jumper links JP3 and JP4 (see Section 4) are used to select resistances for
End-of-Line (EOL) wiring applications.
If EOL wiring is not used, the headers should be left in the default (O/C) position.
If the required resistance values are not available, leave the headers in the O/C position
and wire in external resistors as normal.
EOL Settings for Texecom Panels
JP3
JP4
Premier & Premier International
2k2
4k7Cexample
EXAMPLES OF EOL JUMPER LINK USE
JP3 Selects the End-of-Line
resistance. Equivalent to wiring
a resistor of the selected value
as shown.
JP4 Selects the resistance
across the alarm relay.
Equivalent to wiring a resistor
of the selected value as shown.
TAMPER - JP3
ALARM - JP4
Double Pole
(jumper links not used)
Dual End-of-Line
(DEOL)