teko Astra-361 Operating Manual

Text of the manual

Astra-361 Version RF

Wireless Water Leak Detector Operating Manual Rev. 361rk-v1_0_en The present operation manual is intended for studying operat- ing principle, correct usage, storage and maintenance of wire- less water leak detector Astra-361ver. RF (hereinafter referred to as “detector”) (Fig. 1). The manufacturer reserves the right to make alteration regarding refinement of the product without prior notification. All changes will be imported into new edition of the operation manual. 1 Function 1.1 The detector is designed for detection of water leak events (except for distilled wa- ter), forming an “Alarm” notification and sending it to receiver Astra-RVA (hereinaf- ter “RVA”) of wireless intrusion and fire de- tection and alarming system Observer I. 1.2 The detector supports three operating frequencies. 1.3 The detector is powered by a battery of CR2450 type (voltage – 3.0 V) or batteries of comparable characteristics and design. 2 Specifications Technical Parameters of Radio channel Operating frequency, MHz ................................................ 433.42 Wireless coverage range, m*, min ......................................... 300 Emission power, mWt, max ..................................................... 10 General Technical Parameters Current consumption, mA, max: - transmitter OFF ............................................................... 0.015 - transmitter ON ...................................................................... 25 Power supply voltage, V ..................................... from 2.25 to 3.0 Overall dimensions, mm, max ................................. 64  46  22 Weight, kg, max ................................................................... 0.05 Average battery service life, years, min .................................... 2 Operating Conditions Temperature range, °С ......................................... from +5 to +50 Relative air humidity, % .................................. up to 93 at + 40 °С no moisture condensation __________________________________ * Along the line-of-sight. Wireless coverage range is largely dependent on the design features of construction, the installation location, the in- terference situation. 3 Delivery Set Wireless water leak detector Astra-361ver. RF ................. 1 pcs. Battery ............................................................................... 1 pcs. Operating manual .......................................................... ..1 copy. 4 Structure Fig. 2 Structurally, the detector is designed as a unit consisting of a base and a removable cover (Fig. 2). The cover is attached to the base with screws. The unit houses a printed circuit board with radio elements. An indicator mounted on the circuit board provides for detector operability supervision. Contact pads are located on the detector body. 5 Information Capacity Table 1 – Notifications processed by indicator and RVA Notification type Indicator RVA Starting detec- tor to standby mode Lights once for 0.5 s after power up - Norm Not lit + Alarm Lights once for 0.2 s when ex- ternal contact are closed (short- ed) by water + Low supply voltage Blinks 3 times every 25 s when the battery charge drops below 2.5-0.1 V + "+" – the notification is given, "– " – the notification is not given Note – When “Low supply voltage” notification appears, re- place the battery within a week. 6 Pre-starting Procedure 6.1 After transportation in conditions differing from those of operation keep detector unpacked under supposed operation conditions for at least 4 hours. WARNING! Check compliance of operating frequen- cies of detector and receiver. 6.2 Registering the detector in the receiver memory Detector is registered at the moment of powering up. Step-1 Unscrew the screws and remove the detector cover Fig. 1 Indicator Cover removed Base Printed circuit board Battery Contact pads

Remove the battery, if installed

Note – Wait at least 40 s before installing the battery back into the detector. If you have no time to wait, short plus-minus contacts of the battery holder using a screwdriver. Step-3 Set the registration mode on a receiver according to pro- cedure described in the «Astra-RVA» operation manual or the Observer I system operation manual (available for free downloading from www.controlex.eu) or Quick Start Guide. Step-4 Install the battery; the indicator lights up for 0.5 s. Step-5 Make sure the registration procedure is completed accord- ing to procedure described in the «Astra-RVA» operation manual or the Observer I system operation manual (availa- ble for free downloading from www.controlex.eu) or Quick Start Guide.  Once registration pro- cedure completed suc- cessfully reassemble de- tector.  In case registration failed repeat steps 2-5 Step-6 After successful detector registering, for long term storage before its installation, it is allowed to switch the detector OFF by removing battery. When installing the detector on-site there is no need to re- register it in the memory of the same receiver, if the memory of the receiver has not been cleared 7 Installation 7.1 The detector shall be mounted on the floor in the lowest place of a room where flooding possibility is monitored (taking into account directions of water flow in case of burst water conduits or heating system pipelines). 7.2 The detector shall be mounted with the contact pads fac- ing downwards. 7.3 Check detector operability: - close (short) the contacts pads (e.g., with a wet cloth), - make sure “Violation” event is displayed on the RVA indica- tor or on the display of Astra-812, Astra-812М control panel. 8 Maintenance To provide for reliable operation of the detector it is recom- mended to test and maintain the detector at least once a month in the following way: - inspect integrity of the detector body; - check its location; - check detector operability as described in 7.3; - clean the detector from any dirt accumulated. 9 Labeling The following data are shown on the label glued to the body: - manufacturer trademark; - detector abbreviated designation; - firmware version; - operating frequency; - month and year of manufacture (last two digits); - conformity mark (if the conformity certificate is available); - bar code, duplicating textual data. 10 EC Conformity Declarations This product is in conformity with the provisions of: R&TTE Directive 1999/5/EC, Article 10.5; EN 60950: 2001 Safety of information technology equipment; EN 50371 Generic standard to demonstrate the compliance of low- power electronic and electrical apparatuses with the basic restrictions related to human exposure to electromagnetic fields (10 MHz - 300 GHz) – General public; EN 301489-17 V1.1.1 (09-2000) Electromagnetic Compatibility and ra- dio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for wideband data Hiperlan equipment; EN 300220-1 V1.3.1 (2000-09) Electromagnetic compatibility and Ra- dio spectrum Matters (ERM); Short range devices; Technical charac- teristics and test methods for radio equipment to be used in the 25 MHz to 1 000 MHz frequency range with power levels ranging up to 500 mWt; Part 1: Parameters intended for regulatory purposes. Construction of the detector provides for protection class IP41. 11 Recycling 11.1 The detector is not dangerous for life, human health and the envi- ronment. On the expiry of product’s lifetime, recycling is done without taking special measures to protect the environment. 11.2 Used batteries shall be returned to the vendor, the service center, the equipment manufacturer or to any company collecting used batter- ies. 12 Manufacturer Warranties 12.1 The manufacturer guarantees the compliance of the detector to specifications on condition that user observes required conditions of transportation, storage, installation and operation. 12.2 The storage warranty period is 5 years and 6 months from the date of manufacture. 12.3 The operation warranty period is 5 years from the date of putting into operation but no longer than 5 years 6 months from the date of manufacturing. 12.4 The manufacturer shall repair or replace a faulty detector during the warranty period. 12.5 The warranty becomes void if: - the user does not follow guidelines of the operating manual; - the detector is mechanically damaged; - repair of the detector by any third-party service apart from the manufacturer. 12.6 Warranty applies to the detector only. An equipment of third-party manufacturers used in conjunction with the detector (including batter- ies) is subject to its own warranty terms and conditions. The manufacturer bears no responsibility for death, injury, prop- erty damage or other incidental or premeditated loss based on user's statement that the device failed to implement its functions. Sales: Controlex GmbH Warranty service and technical support: ТЕКО-TD Philosophenweg 31-33 47051 Duisburg, Germany Phone: +49 (0) 203 / 393 91 188 Fax: +49 (0) 203 / 393 91 189 GSM: +49 (0) 178 / 218 48 22 E-mail: [email protected] Web: www.controlex.eu Prospect Pobedy str. 19 420138 Kazan, Russia Phone: +7 (843) 261-55-75 Fax: +7 (843) 261-58-08 E-mail: [email protected] [email protected] Web: www.teko.biz Made in Russia

Other Security Sensors Manuals