PROJECT & SYSTEM DESCRIPTION

1.1 Project Description Project Name Guidelines Maximum flow rate 10, 20, or 30 GPM Design dose 40, 80, or 120 mJ/cm2 Operating pressure 15 psi (103 kPa) - 125 psi (862 kPa) Ambient air temp. 0°C (32°F) - 40°C (104°F) Ambient water temp. 2°C (35.6°F) - 40°C (104°F) Hardness 120 ppm (7 grains / gallon) max.* Manganese content 0.05 ppm max.* Iron content 0.3 ppm max.* UVT 75% min.* *after pretreatment 1.2 System Description Model PRO10 PRO20 PRO30 Quantity Chamber Material 316L SST Dimensions 21.4” x 4” (55 x 10 cm) 31” x 4” (78 x 10 cm) 41” ...

3.7.2 LightWise™ Technology

VIQUA’s new LightWise™ technology allows the system’s electronic controller to automatically reduce lamp power during periods of no water flow. The dimming capability ultimately reduces the rate of sleeve fouling. Benefits • Lower maintenance; up to 60% less maintenance. • Lower energy consumption; estimated savings of 30%. • Lower operating temperature; maintained below 40°C in typical no flow conditions. • Increased electrical efficiency minimizes carbon footprint. 40 45 50 55 60 65 70 75 80 85 0 10 20 30 40 50 60 70 80 90 100 %UVT % of Rated S ...

ten (10) years from the date of purchase

Electrical (controller) and Hardware Components five (5) years from the date of purchase UV Lamps, Sleeves, and UV Sensors one (1) year from the date of purchase ...

The controller is equipped with the following features:

1. Audible alarm 2. Audible alarm mute 3. Replacement lamp counter reset 4. Lamp operation indicator 5. Controller operation indicator 6. Solenoid valve operation indicator 7. Fan operation indicator 8. Sensor reading indicator 9. Flow meter operation indicator Firmware in the controllers monitors flow rate and sensor input for set point conditions. Controllers will enter audible and visual alarm if the sensor input is too low given the measured flow rate. Set points depend on the Adjustable Alarm Set Points (se ...

2 2.0 PRODUCT DRAWINGS 2.1 Install Diagram Item L S (min.) Ø A (max.) B C D (max.) PRO10 21.4” (55 cm) 12” (30 cm) 4” (10 cm) 72” (182 cm) 6.5” (16.5 cm) 13” (33 cm) 48” (122 cm) PRO20 31” (78 cm) 12” (30 cm) 4” (10 cm) 72” (182 cm) 6.5” (16.5 cm) 13” (33 cm) 48” (122 cm) PRO30 41” (103 cm) 12” (30 cm) 4” (10 cm) 72” (182 cm) 6.5” (16.5 cm) 13” (33 cm) 48” (122 cm) ...

The flow meter measures the flow rate of water passing through the UV systems. The

flow meter utilizes a paddle wheel and a flow detect arm to ensure reliable measurements. 3.7 Product Features and Benefits 3.7.1 Real-Time UV Dose Monitoring VIQUA’s PRO systems come equipped with real-time UV dose monitoring which utilizes data from both the flow meter and the UV sensor. Benefits • More accurate assessment of true operating conditions. • More time between maintenance. • Lower probability of false alarms. 40 45 50 55 60 65 70 75 80 85 0 10 20 30 40 50 60 70 80 90 100 % ...

Viqua PRO10 user guide recommended for: ABSOLUTE H2O IHS-10, D4, H, FB-34PR-PS, AWP-SE1 series.

⚠️ Download Safety

The Water Filtration Systems Manual  (20 pages) is completely safe to download (last scan date: 08/01/2026).

Related PDF Instructions for Viqua PRO10:

Water Filtration Systems Equipment: Frequently Requested

Have some Questions about Viqua PRO10 Device?

Get valuable and actionable advices from other Viqua PRO10 device users. Describe your problem or question, regarding the using of PRO10, in as much detail as possible, and other users will be able to answer you.