SF71060M & SF71060MP

Revision A3 SF71060M & SF71060MP Industrial 10-Port 10/100/1000Base Managed PoE/PoE+ Switch with 100/1000Base SFP Slots IInnssttaallllaattiioonn G Guuiiddee vv11..0000 © November 2017 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com

SF71060M & SF71060MP

Revision A3 Copyright  VERSITRON, Inc. All rights reserved. All brand and product names are trademarks or registered trademarks of their respective companies. PROPRIETARY DATA All data in this manual is proprietary and may not be disclosed, used or duplicated, for procurement or manufacturing purposes, without prior written permission by VERSITRON. VERSITRON LIFETIME WARRANTY All VERSITRON products are covered by a Lifetime Warranty against defects in materials and workmanship. This coverage is applicable to the original purchaser and is not transferable. We repair, or at our option, replace parts/products that, during normal usage and operation, are proven to be defective during the time you own the products, provided that said products and parts are still manufactured and/or available. Such repair/replacement is subsequent to receipt of your product at our facility and our diagnostic evaluation and review of the unit. Advance replacements are not provided as part of the warranty coverage. This warranty does not cover damage to products caused by misuse, mishandling, power surges, accident, improper installation, neglect, alteration, improper maintenance, or other causes which are not normal and customary applications of the products and for which they were not intended. No other warranty is expressed or implied, and VERSITRON is not liable for direct, indirect, incidental or consequential damages or losses. In the unlikely event a warranty issue should arise, simply contact us at 302-894-0699 or 1-800-537-2296 or via email at [email protected] to obtain a Return Material Authorization (RMA) number, along with instructions for returning your product.

SF71060M & SF71060MP

Revision A3 About This Manual Copyright Copyright © 2017 VERSITRON, Inc. All rights reserved. The products and programs described in this manual are licensed products of VERSITRON, Inc. This manual contains proprietary information protected by copyright, and this manual and all accompanying hardware, software and documentation are copyrighted. No parts of this manual may be copied, photocopied, reproduced, translated or reduced to any electronic medium or machine-readable from by any means by electronic or mechanical. Including photocopying, recording, or information storage and retrieval systems, for any purpose other than the purchaser’s personal use, and without the prior express written permission of VERSITRON, Inc. Purpose This manual gives specific information on how to operate and use the management functions of the SF71060M & SF71060MP. Audience The Manual is intended for use by network administrators who are responsible for operating and maintaining network equipment; consequently, it assumes a basic working knowledge of general switch functions, the Internet Protocol (IP), and Simple Network Management Protocol (SNMP). Conventions The following conventions are used throughout this manual to show information. NOTE: Emphasizes important information or calls your attention to related features or instructions. WARNING: Alerts you to potential hazard that could cause personal injury. CAUTION: Alerts you to a potential hazard that could cause loss of data, or damage the system or equipment. Warranty See the VERSITRON, Inc. warranty statement. Disclaimer VERSITRON, Inc. does not warrant that the hardware will work properly in all environments and applications, and marks no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose. VERSITRON, Inc. disclaims liability for any inaccuracies or omissions that may have occurred. Information in this User’s Manual is subject to change without notice and does not represent a commitment on the part of VERSITRON, Inc.. VERSITRON, Inc. assumes no responsibility for any inaccuracies that may be contained in this User’s Manual. VERSITRON, Inc. makes no commitment to update or keep current the information in this User’s Manual, and reserves the righter to make improvements to this User’s Manual and /or to the products described in this User’s Manual, at any time without notice.

SF71060M & SF71060MP

Revision A3 TRADEMARKS Ethernet is a registered trademark of Xerox Corp. FCC NOTICE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including the interference that may cause undesired operation. CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community. Such marking is indicative that this equipment meets or exceeds the following technical standards: EMC Class A EN 61000-6-4:2007/A1:2011 EN 61000-3-2:2006/A1:2009/A2:2009 EN 61000-3-3:2008 EN 61000-6-2:2005 IEC 61000-4-2:2008 IEC 61000-4-3:2010 IEC 61000-4-4:2012 IEC 61000-4-5:2005 IEC 61000-4-6:2008 IEC 61000-4-8:2009 IEC 61000-4-11:2004

SF71060M & SF71060MP

Revision A3 Table of Contents 0B1. Introduction ...................................................................................................................................................... 4 1.1 Features ............................................................................................................................... 5 1.2 Product Panels ..................................................................................................................... 6 1.3 LED Indicators ...................................................................................................................... 7 1.4 Specifications ....................................................................................................................... 7 1B2. Installation ...................................................................................................................................................... 10 10B2.1 Unpacking .......................................................................................................................... 10 2.2 Safety Cautions .................................................................................................................. 10 12B2.3 DIN-Rail Mounting .............................................................................................................. 11 13B2.4 Panel Mounting .................................................................................................................. 13 14B2.5 Applying Power .................................................................................................................. 15 15B2.6 Alarm Relay Output ............................................................................................................ 17 2.7 Powered via PoE over Cat.5 (Standard Model) .................................................................. 18 2.8 Reset Button ...................................................................................................................... 18 2.9 Making UTP Connections ................................................................................................... 19 2.10 Making Fiber Connection .................................................................................................. 20 2.11 Making PoE PSE Connections (PoE Model) ..................................................................... 22 1306B2.12 LED Indication .................................................................................................................. 23 2.13 Making Console Connection ............................................................................................. 24 3. Manage the Switch ........................................................................................................................................ 25 3.1 IP Address & Password ...................................................................................................... 25 3.2 Configuring IP Address & Password via console and telnet ................................................ 25 3.3 Configuring IP Address via Web Interface .......................................................................... 26 3.4 Reference Manuals for Web, Console, Telnet Management ............................................... 28 3.5 Configuration for SNMP Management ................................................................................ 29 3.6 SNMP MIBs........................................................................................................................ 30

SF71060M & SF71060MP

Revision A3 0B1. Introduction The SF71060M & SF71060MP switches are Industrial 10/100/1000Base managed switches featuring:  Eight 10/100/1000Mbps copper ports  Two dual-speed SFP slots for 100Base-FX or 1000Base-X Model Definitions Model Copper ports SFP slots PoE PSE function Power via DC input Powered via PoE capable Software managed SF71060M 8 2 dual-speed -    SF71060MP 8 2 dual-speed 4 PSE ports  - 

SF71060M & SF71060MP

Revision A3 1.1 Features  Eight 10/100/1000Mbps RJ-45 and two dual-speed SFP slots  All copper ports support auto-negotiation and auto-MDI/MDI-X detection.  Two SFP slots support dual speed for 100BASE-FX and 1000BASE-X SFP modules.  Full wire speed forwarding  Supports 802.3x flow control for full-duplex and backpressure for half-duplex  Port link aggregation function with LACP support  Supports SFP with Digital Diagnostic Monitoring (DDM)  Alternatively powered via PoE if direct DC power not available  Optional four 802.3at-compliant PoE+ PSE ports  SNMP private MIB for DDM status, reboot, TFTP firmware update (MIB file Rev1.05 or up)  Optical Power Alarm (OPA) function  Auto Laser Shutdown (ALS) function (supported in H/W Ver.E up)  Management: - HTTP/HTTPS/SSHv2/CLI telnet/CLI console/SNMP v1/v2c/v3/RMON - DHCP/DHCPv6 client, DHCP relay, DNS client, NTPv4 - IPv6 support, System Syslog, Configuration down/upload, Software upload  Security: - NAS, 802.1X, MAC-based/Web/CLI authentication - IP MAC binding, TACACS+, IP source guard  Layer 2: - QoS, 802.1Q/MAC-based/Protocol-based/Private/IP subnet VLAN, Port Isolation - Storm control for UC/MC/BC packets, Static MAC configuration - IGMP v2/v3 snooping, MLD v1/v2 snooping, DHCP snooping - Multiple Spanning Tree - MSTP. RSTP, STP  Auto Multi-Ring (KAMR) Technology: - Fast failover response time, Auto recovery when failure is repaired - Supports up to five redundant rings, Works with RSTP network

SF71060M & SF71060MP

Revision A3 1.2 Product Panels The following figure illustrates the front panel and rear panel of the switch: SF71060M Front panel SF71060MP Front panel

SF71060M & SF71060MP

Revision A3 154BUpper panel 1.3 LED Indicators LED Function PWR Power status Mgt. Management status Port 1~ 8 SPEED LEDs Speed & PoE status Port 1~ 8 LINK LEDs Link & activity status SFP 9, 10 LED Speed & link & activity status of SFP port 1.4 Specifications 10/100/1000 Copper Ports (Port 1 ~ Port 8) Compliance IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3u 1000Base-T Connectors Shielded RJ-45 jacks Pin assignments Auto MDI/MDI-X detection Configuration Auto-negotiation or software control Transmission rate 10Mbps, 100Mbps, 1000Mbps Duplex support Full/Half duplex Network cable Cat.5 UTP Dual-speed SFP Slots (Port 9, Port 10) Compliance IEEE 802.3u 100Base-FX IEEE 802.3z 1000Base-SX/LX (mini-GBIC) Connectors SFP slots for optional SFP fiber modules

SF71060M & SF71060MP

Revision A3 Configuration Auto 1000Mbps, Full duplex Forced 100Mbps, Full duplex Transmission rate 100Mbps and 1000Mbps Network cables MMF 50/125 60/125, SMF 9/125 Eye safety IEC 825 compliant Console Port Interface RS-232, DTE type Connector Shielded RJ-45 Switch Functions MAC Addresses Table 8K entries Forwarding & filtering Non-blocking, full wire speed Switching technology Store and forward Maximum packet length 9.6K bytes IP Multicast groups 8192 supported Flow control IEEE 802.3x pause frame base for full duplex operation Back pressure for half duplex operation Power over Ethernet PSE Function (SF71060MP) PSE Ports Port 1 ~ Port 4 Power output pins Positive of power voltage: pin 1,2 Negative of power voltage: pin 3,6 Standard IEEE 802.3at Classification PD Class 0 ~ 4 detection Power Delivery 30W max. (per port) at port output for Cat.5 distance up to 100 meters Protection Under voltage protection Over voltage protection Over current detection Powered via Power over Ethernet (SF71060M) PD Port Port 2 PoE Standard IEEE 802.3af PoE PD (Powered Device) PSE Support IEEE 802.3af & 802.3at PSE Power Classification Class 3 Input Voltage (Vpoe) 36 ~ 57VDC via Cat.5

SF71060M & SF71060MP

Revision A3 Power reception pins Positive of PoE power voltage: pin 1,2,4,5 Negative of power voltage: pin 3,6,7,8 Terminal Block Connector DC power input Screwed euro terminal block: 2 pairs of +/- contacts Operating Input Voltages +7 ~ +60VDC (General applications) +45 ~ +57VDC (PoE applications) Power consumption 9W max. (Full load with no PoE support) 130W max. (Full load with 4 PoE max. output) Alarm relay output 2 terminal contacts AR+/AR- (30VDC/1A max. or 120VAC/0.5A max.) Alarm events Power failure, Specific port link fault (software configured), OPA * Warning: The -48VDC power supply is not supported. 856BUMechanical Dimensions 5.51 x 4.17 x 1.65 inches (H x D x W) Housing Enclosed metal with no fan Mounting Optional Din-rail mounting or Panel mounting 860BUEnvironmental Operating Temperature Typical -30℃ ~ +70℃* Storage Temperature -40℃ ~ +85℃ Relative Humidity 5% ~ 90% non-condensing * +60℃ ~ +70℃ with 1m/s air flow 864BUElectrical Approvals FCC Part 15 rule Class A CE EMC, CISPR11 Class A Safety / LVD IEC 60950-1

SF71060M & SF71060MP

Revision A3 1B2. Installation 10B2.1 Unpacking The product package contains:  One SF71060M or SF71060MP Switch  One console cable 2.2 Safety Cautions To reduce the risk of bodily injury, electrical shock, fire, and damage to the product, observe the following precautions.  Do not service any product except as explained in your system documentation.  Opening or removing covers may expose you to electrical shock.  Only a trained service technician should service components inside these compartments.  If any of the following conditions occur, unplug the product from the electrical outlet and replace the part or contact VERSITRON:  The power cable, extension cable, or plug is damaged.  An object has fallen into the product.  The product has been exposed to water.  The product has been dropped or damaged.  The product does not operate correctly when you follow the operating instructions.  Do not push any objects into the openings of your system. Doing so can cause fire or electric shock by shorting out interior components.  Operate the product only from the type of external power source indicated on the electrical ratings label. If you are not sure of the type of power source required, consult VERSITRON or local power company.

SF71060M & SF71060MP

Revision A3 12B2.3 DIN-Rail Mounting An optional DIN-rail mounting bracket can be purchased for mounting the switch in an industrial DIN-rail enclosure. The steps to mount the switch onto a DIN rail are: 1. Install the mounting bracket onto the switch as shown below: 2. 128BAttach the bracket to the lower edge of the DIN rail and push the unit upward until the bracket can clamp on the upper edge of the DIN rail. 3. Clamp the unit to the DIN rail and make sure it is mounted securely.

SF71060M & SF71060MP

Revision A3 13B2.4 Panel Mounting An optional panel mounting bracket is available for mounting the switch on a flat surface. The mounting steps are: 1. Install the mounting bracket onto the switch as shown below: 2. 1291BScrew the bracket onto the switch. 3. Screw the switch onto a panel. Three screw locations are shown below:

SF71060M & SF71060MP

Revision A3 14B2.5 Applying Power Pin Assignments of the terminal block connector  Vdc Positive () input terminal  Vdc Negative () input terminal  Vdc Positive () input terminal  Vdc Negative () input terminal AR+ Alarm relay output positive () terminal AR Alarm relay output negative () terminal Any of the Vdc+/Vdc- pairs can be used to receive DC power from an external power system. Or, one can be used to deliver the power received to another switch in a daisy-chain application. Vdc Input specifications Applications Power per PSE port DC working voltage General - +7V ~ +60VDC PoE 15.4W max. +45V ~ +57VDC (Typical 48V) High power PoE (PoE+) 30W max. +45V ~ +57VDC (+52V up for 30W) WARNING: The -48VDC power supply is not supported. Caution: Do not apply direct DC IN power and PoE power at the same time. Unplug DC IN when PoE power is connected. Disconnect PoE power when DC IN is used.

SF71060M & SF71060MP

Revision A3 Three 2P terminal plugs are provided with the switch. Two of the three plugs are used for Vdc interfaces respectively. The plug is shown below: 184BPower wires : 24 ~ 12AWG (IEC 0.5~2.5mm2) Install the power source wires into the plug properly, and then install the terminal plug into the switch. If daisy-chaining power to another switch device is required, install the power wires and then install the terminal plug into each switch. Then, use the other Vdc contacts. Note: 1. Only up to four device units can be daisy-chained to receive power from one main power input source. 2. The maximal length of the power wire is 1 meter.

SF71060M & SF71060MP

Revision A3 15B2.6 Alarm Relay Output An alarm relay output is provided for reporting failure events to a remote alarm relay monitoring system. The replay output is provided with two contacts in the terminal block connector next to the Vdc interfaces. Pin Assignments of the Alarm Relay output AR+ Alarm relay output positive () terminal AR Alarm relay output negative () terminal Use the provided 2P terminal plug for signal wiring and plug into the AR+/- contacts. Alarm Events  Input power failure  Specific port link down (The specific ports can be configured by software.)  OPA alarm if optical power is higher than a upper limit setting or lower than a lower limit setting Relay Logic Normal: AR+ and AR- shorted Alarm: AR+ and AR- open Note: Be sure the voltage applied on AR+/- contacts is within the specification of 30VDC/1A max. or 120VAC/0.5A max.

SF71060M & SF71060MP

Revision A3 2.7 Powered via PoE over Cat.5 (SF71060M) Port 2 is equipped with the function of receiving power from a connected PoE PSE device over Cat.5 cable. The remote PoE PSE devices can be a mid-span PoE injector or end-span PoE switch. The switches can support the following PSE:  802.3af compliant PSE (Typical, Type 1 PSE) Possible voltages received: +36 ~ +57VDC  802.3at compliant PSE (High power PoE, Type 2 PSE) Possible voltages received: +42.5 ~ +57VDC 2.8 Reset Button The reset button is used to perform a reset of the switch. It is not used in normal cases and can be used for diagnostic purposes. If any network problem is suspected, it is useful to push the button to reset the switch without turning off the power. Check whether the network has recovered. The button can also be used to restore the software configuration settings to factory default values. The operations are: Operation Function Press the button and release during switch operation Reset & boot up the switch. The behavior is same as power boot procedure. Press the button until MNGT-LED is steady ON Boot & restore all factory default settings

SF71060M & SF71060MP

Revision A3 2.9 Making UTP Connections The 10/100/1000 RJ-45 copper ports support the following connection types and distances: Network Cables 10BASE-T: 2-pair UTP Cat. 3, 4, 5 , EIA/TIA-568B 100-ohm 100BASE-TX: 2-pair UTP Cat. 5, EIA/TIA-568B 100-ohm 1000BASE-T: 4-pair UTP Cat. 5 or higher (Cat.5e is recommended), EIA/TIA-568B 100-ohm Link distance: Up to 100 meters for all above Auto MDI/MDI-X Function This function allows the port to auto-detect the twisted-pair signals and adapts itself to form a valid MDI to MDI-X connection with the remote connected device automatically. No matter if a straight through cable or crossover cable is connected, the ports can sense the receiving pair automatically and configure itself to match the rule for MDI to MDI-X connection. It simplifies the cable installation. Auto-negotiation Function The ports are featured with the auto-negotiation function and full capability to support connection to any Ethernet devices. The port performs a negotiation process for the speed and duplex configuration with the connected device automatically each time a link is being established. If the connected device is also auto-negotiation capable, both devices will come out with the best configuration after the negotiation process. If the connected device is incapable in auto-negotiation, the switch will sense the speed and use half duplex for the connection. Port Configuration Management For making proper connection to an auto-negotiation incapable device, it is suggested to use port control function via the software management to set forced mode and specify the speed and duplex mode which match the configuration used by the connected device.

SF71060M & SF71060MP

Revision A3 2.10 Making Fiber Connection The dual-speed SFP slots, Port 9 and Port 10 must be populated with a fiber optic SFP module for making fiber connections. Types of fiber optic SFP module supported: 1000Mbps based 1000BASE-X 100Mbps based 100BASE-FX Installing the fiber optic SFP module: 1. Turn off the power to the switch. 2. Insert the fiber optic SFP module into the SFP slot until the module securely seated slot and place the bail in lock position. Connecting Fiber Cables LC connectors are commonly equipped on most fiber optic SFP modules. Identify TX and RX connector before making cable connection. The following figure illustrates a connection example between two fiber ports: Make sure the Rx-to-Tx connection rule is followed on the both ends of the fiber cable.

SF71060M & SF71060MP

Revision A3 Network Cables Multimode (MMF) - 50/125, 62.5/125 Single mode (SMF) - 9/125 Port Speed Configuration There are three options for configuring port speed via the software for SFP Port 9 and Port 10. The options are: Auto Auto-detection for the type of the installed SFP transceiver by reading DDM data 100Mbps transceiver: Non-auto-negotiation (forced), 100Mbps, full duplex 1000Mbps transceiver: Auto-negotiation, 1000Mbps, full duplex 100Mbps FDX Non-auto-negotiation (forced), 100Mbps, full duplex 1Gbps FDX Auto-negotiation, 1000Mbps, full duplex

SF71060M & SF71060MP

Revision A3 2.11 Making PoE PSE Connections (SF71060MP) This section describes how to make a connection between an SF71060MP PSE port and a PoE PD device. To make a PoE connection, the following check points should be noted: 1. For safety reasons, the connected PoE PD (Powered Device) must be a IEEE 802.3at or IEEE 802.3af-compliant device. Incompliant devices are not supported by the SF71060MP. 2. The Cat.5 cables used for the connections must be 4-pair cables. The power is sent over the spare pairs (4,5) (7,8) of the cable. The maximum distance supported is 100 meters. 3. The power voltage supplied to the switch must be within the range as specified in section 2.5 to make the PoE function work. The PSE ports are equipped with the following capabilities: 1. Detection for an IEEE 802.3af /802.3at compliant PD. 2. No power is supplied to a device which is classified non-IEEE 802.3af compliant PD. 3. No power is supplied when no connection exists on the port. 4. The power is cut off immediately from powering condition when a disconnection occurs. 5. The power is cut off immediately from powering condition when overload occurs. 6. The power is cut off immediately from powering condition when over-current occurs. 7. The power is cut off immediately from powering condition when short circuit condition occurs. The figure below illustrates a connection example:

SF71060M & SF71060MP

Revision A3 1306B2.12 LED Indication LED Function Color State Interpretation PWR Power status Green ON Power is supplied to the switch. OFF P is not supplied to the switch. Mgt. Management status Green OFF The switch is in initialization and diagnostics. Yellow BLINK Initialization completed with diagnostic error or system error found during normal operation Green ON Initialization completed with no error Port 1 ~ Port 8 SPEED_LED Port speed status Green ON Speed is 1000Mbps. Yellow ON Speed is 10Mbps or 100Mbps. BLINK PoE power is on. LINK_LED Port link status Green ON Port link is established. (No traffic) Green BLINK Port link is up and there is traffic. OFF Port link is down. Port 9 ~ Port 10 Speed _LED Port speed/link status Green ON A 1000Mbps link is established. Yellow ON A 100Mbps link is established. BLINK Activity status OFF Port link is down.

SF71060M & SF71060MP

Revision A3 2.13 Making Console Connection The connector designed for the console port is an RJ-45. Pin Assignments: Pin RS-232 signals IN/OUT 1,2,7,8 NC 3 RxD IN 6 TxD OUT 4,5 GND Baud Rate information: Baud rate - 115200 Data bits - 8 Parity - None Stop bit - 1 Flow control – None

SF71060M & SF71060MP

Revision A3 3. Manage the Switch The switches provide the following methods to configure and monitor the switch:  Out of band telnet CLI management via the console port  In-band management via telnet CLI over TCP/IP network  In-band management via web interface over TCP/IP network  In-band SNMP management over TCP/IP network 3.1 IP Address & Password The IP Address is an identification of the switch in a TCP/IP network. Each switch should be designated a new and unique IP address in the network. The switch is shipped with the following factory default settings for software management: Default IP address of the switch: 192.168.0.2 / 255.255.255.0 The switch uses local authentication instead of RADIUS authentication with factory defaults: Fixed Username: admin Default password: No password is required with the factory default. However, the password is used for local authentication in accessing the switch via the console, telnet and Http web-based interface. For security reasons, it is recommended to change the default settings for the switch before deploying it to your network. 3.2 Configuring IP Address & Password via console and telnet [IP Address] setting command is in IP command group. >IP Setup [] [] [] [] Parameters: : IP address (a.b.c.d) : IPv4 subnet mask (a.b.c.d) : IPv4 router (a.b.c.d) : VLAN ID (1-4095) [IPv6 Address] setting command is also in the IP command group.

SF71060M & SF71060MP

Revision A3 >IP IPv6 Setup [] [] [] Parameters: : IPv6 address is in 128-bit records represented as eight fields of up to four hexadecimal digits with a colon separates each field (:). : IPv6 subnet mask : IPv6 router [Password] setting command is also in Security/Switch/Users command group. Security Switch Users Configuration Security Switch Users Add Security Switch Users Delete Refer to “Operation manual for telnet and console management”. 3.3 Configuring IP Address via Web Interface Start Web Browser Start your browser software and enter the default IP address of the switch to which you want to connect. The IP address is used as the URL for the browser software to search the device. URL: http:/192.168.0.2/ Login to Switch Unit When the browser software connects to the switch successfully, a Login screen is provided for you to login into the device as shown below:

SF71060M & SF71060MP

Revision A3 Enter the following default values in the login page: Default username: admin Default password:  No password is required. Click OK to login into the switch. Web Page after a Successful Login: Select [Configuration] -> [System] -> [IP] to configure IP address

SF71060M & SF71060MP

Revision A3 Configuration Description DHCP Client Enable the DHCP client by checking this box. IP Address Provide the IP address of this switch unit. IP Mask Provide the IP mask of this switch unit. IP Router Provide the IP address of the default router for this switch unit. VLAN ID Provide the managed VLAN ID. The allowed range is 1 through 4095. DNS Server Provide the IP address of the DNS Server in dotted decimal notation. DNS Proxy When DNS proxy is enabled, DUT will relay DNS requests to the current configured DNS server on DUT, and reply as a DNS resolver to the client device on the network. Save Click to save the changes. Reset Click to undo any changes made locally and revert to previously saved values. Renew Click to renew DHCP. This button is only available if DHCP is enabled. 3.4 Reference Manuals for Web, Console, Telnet Management The following manuals are also available separately for Console, Telnet and Web management: Operation manual - telnet & console management xxxxxx.doc Operation manual - web management xxxxx.doc The manuals describe the detailed commands and information.

SF71060M & SF71060MP

Revision A3 3.5 Configuration for SNMP Management The switch supports SNMP v1, SNMP v2c, and SNMP v3 management. Make sure the related settings are well-configured for the switch before you start the SNMP management from an SNMP manager. Using Telnet Interface The following are available commands in telnet SNMP command group to configure SNMP-related settings: >SNMP Configuration >SNMP Mode [enable|disable] >SNMP Version [1|2c|3] >SNMP Read Community [] >SNMP Write Community [] >SNMP Trap Mode [enable|disable] >SNMP Trap Version [1|2c|3] >SNMP Trap Community [] >SNMP Trap Destination [] >SNMP Trap IPv6 Destination [] >SNMP Trap Authentication Failure [enable|disable] >SNMP Trap Link-up [enable|disable] >SNMP Trap OPA [enable|disable] >SNMP Trap Inform Mode [enable|disable] >SNMP Trap Inform Timeout [] >SNMP Trap Inform Retry Times [] >SNMP Trap Probe Security Engine ID [enable|disable] >SNMP Trap Security Engine ID [] >SNMP Trap Security Name [] >SNMP Engine ID [] >SNMP Community Add [] [] >SNMP Community Delete >SNMP Community Lookup [] >SNMP User Add [MD5|SHA] [] [DES] [] >SNMP User Delete >SNMP User Changekey [] >SNMP User Lookup [] >SNMP Group Add >SNMP Group Delete >SNMP Group Lookup []

SF71060M & SF71060MP

Revision A3 >SNMP View Add [included|excluded] >SNMP View Delete >SNMP View Lookup [] >SNMP Access Add [] [] >SNMP Access Delete >SNMP Access Lookup [] Using Web Interface: The commands supports configuration for: - Basic system configuration for SNMP v1 and SNMP v2c - Basic system configuration for SNMP v1 trap, SNMP v2c trap and SNMP v3 trap - Communities that permit to access to SNMPv3 agent - USM (User-based Security Model) user table for SNMPv3 - VACM (View-based Access Control Model) Viewer table for SNMPv3 - Group table for SNMPv3 - Accesses group table for SNMPv3 3.6 SNMP MIBs The switch provides the following SNMP MIBs: - RFC 1213 - MIB II - RFC 2674 - QBridge MIB (VLAN MIB) - RFC 2819 - RMON (Group 1, 2. 3 & 9) - RFC 2863 - Interface Group (IF) MIB - RFC 3411 - SNMP Management Frameworks - RFC 3414 - User Based Security Model (USM) - RFC 3415 - View Based Access Control Model (VACM) - RFC 3621 - Power Ethernet MIB - RFC 3635 - EtherLike MIB - RFC 3636 - 802.3 Medium Attachment Units (MAUs) MIB - RFC 4133 - Entity MIB

SF71060M & SF71060MP

Revision A3 - RFC 4188 - Bridge MIB - RFC 4668 - RADIUS Authentication Client MIB - RFC 5519 - Multicast Group Membership Discovery (MGMD) MIB - IEEE 802.1 MSTP MIB - IEEE 802.1AB LLDP MIB - IEEE 802.1X Port Access Entity (PAE) MIB - TIA 1057 LLDP Media Endpoint Discovery (MED) MIB - IEEE 802.1-Q-BRIDGE MIB - Private SFPDDM MIB - Private reboot MIB (Remote boot over SNMP) - Private TFTP firmware update MIB (TFTP Firmware update via SNMP)