SF71060M & SF71060MP
Revision A3
SF71060M & SF71060MP
Industrial 10-Port 10/100/1000Base
Managed PoE/PoE+ Switch
with 100/1000Base SFP Slots
IInnssttaallllaattiioonn G
Guuiiddee
vv11..0000
© November 2017
VERSITRON, Inc.
83 Albe Drive / Suite C
Newark, DE 19702
www.versitron.com
SF71060M & SF71060MP
Revision A3
Copyright VERSITRON, Inc. All rights reserved. All brand and product names are trademarks or
registered trademarks of their respective companies.
PROPRIETARY DATA
All data in this manual is proprietary and may not be disclosed,
used or duplicated, for procurement or manufacturing purposes,
without prior written permission by VERSITRON.
VERSITRON LIFETIME WARRANTY
All VERSITRON products are covered by a Lifetime Warranty against defects in materials and
workmanship. This coverage is applicable to the original purchaser and is not transferable.
We repair, or at our option, replace parts/products that, during normal usage and operation, are proven
to be defective during the time you own the products, provided that said products and parts are still
manufactured and/or available. Such repair/replacement is subsequent to receipt of your product at
our facility and our diagnostic evaluation and review of the unit. Advance replacements are not
provided as part of the warranty coverage.
This warranty does not cover damage to products caused by misuse, mishandling, power surges,
accident, improper installation, neglect, alteration, improper maintenance, or other causes which are
not normal and customary applications of the products and for which they were not intended. No
other warranty is expressed or implied, and VERSITRON is not liable for direct, indirect, incidental or
consequential damages or losses.
In the unlikely event a warranty issue should arise, simply contact us at 302-894-0699 or
1-800-537-2296 or via email at [email protected] to obtain a Return Material Authorization
(RMA) number, along with instructions for returning your product.
SF71060M & SF71060MP
Revision A3
About This Manual
Copyright
Copyright © 2017 VERSITRON, Inc. All rights reserved.
The products and programs described in this manual are licensed products of
VERSITRON, Inc. This manual contains proprietary information protected by copyright,
and this manual and all accompanying hardware, software and documentation are
copyrighted. No parts of this manual may be copied, photocopied, reproduced,
translated or reduced to any electronic medium or machine-readable from by any
means by electronic or mechanical. Including photocopying, recording, or information
storage and retrieval systems, for any purpose other than the purchaser’s personal use,
and without the prior express written permission of VERSITRON, Inc.
Purpose
This manual gives specific information on how to operate and use the management
functions of the SF71060M & SF71060MP.
Audience
The Manual is intended for use by network administrators who are responsible for
operating and maintaining network equipment; consequently, it assumes a basic
working knowledge of general switch functions, the Internet Protocol (IP), and Simple
Network Management Protocol (SNMP).
Conventions
The following conventions are used throughout this manual to show information.
NOTE: Emphasizes important information or calls your
attention to related features or instructions.
WARNING: Alerts you to potential hazard that could cause
personal injury.
CAUTION: Alerts you to a potential hazard that could cause
loss of data, or damage the system or equipment.
Warranty
See the VERSITRON, Inc. warranty statement.
Disclaimer
VERSITRON, Inc. does not warrant that the hardware will work properly in all
environments and applications, and marks no warranty and representation, either
implied or expressed, with respect to the quality, performance, merchantability, or
fitness for a particular purpose. VERSITRON, Inc. disclaims liability for any inaccuracies
or omissions that may have occurred. Information in this User’s Manual is subject to
change without notice and does not represent a commitment on the part of
VERSITRON, Inc.. VERSITRON, Inc. assumes no responsibility for any inaccuracies that
may be contained in this User’s Manual. VERSITRON, Inc. makes no commitment to
update or keep current the information in this User’s Manual, and reserves the righter
to make improvements to this User’s Manual and /or to the products described in this
User’s Manual, at any time without notice.
SF71060M & SF71060MP
Revision A3
TRADEMARKS
Ethernet is a registered trademark of Xerox Corp.
FCC NOTICE
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) This device must accept any interference received, including the interference that
may cause undesired operation.
CE NOTICE
Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community. Such
marking is indicative that this equipment meets or exceeds the following technical standards:
EMC Class A
EN 61000-6-4:2007/A1:2011
EN 61000-3-2:2006/A1:2009/A2:2009
EN 61000-3-3:2008
EN 61000-6-2:2005
IEC 61000-4-2:2008
IEC 61000-4-3:2010
IEC 61000-4-4:2012
IEC 61000-4-5:2005
IEC 61000-4-6:2008
IEC 61000-4-8:2009
IEC 61000-4-11:2004
SF71060M & SF71060MP
Revision A3
Table of Contents
0B1. Introduction ...................................................................................................................................................... 4
1.1 Features ............................................................................................................................... 5
1.2 Product Panels ..................................................................................................................... 6
1.3 LED Indicators ...................................................................................................................... 7
1.4 Specifications ....................................................................................................................... 7
1B2. Installation ...................................................................................................................................................... 10
10B2.1 Unpacking .......................................................................................................................... 10
2.2 Safety Cautions .................................................................................................................. 10
12B2.3 DIN-Rail Mounting .............................................................................................................. 11
13B2.4 Panel Mounting .................................................................................................................. 13
14B2.5 Applying Power .................................................................................................................. 15
15B2.6 Alarm Relay Output ............................................................................................................ 17
2.7 Powered via PoE over Cat.5 (Standard Model) .................................................................. 18
2.8 Reset Button ...................................................................................................................... 18
2.9 Making UTP Connections ................................................................................................... 19
2.10 Making Fiber Connection .................................................................................................. 20
2.11 Making PoE PSE Connections (PoE Model) ..................................................................... 22
1306B2.12 LED Indication .................................................................................................................. 23
2.13 Making Console Connection ............................................................................................. 24
3. Manage the Switch ........................................................................................................................................ 25
3.1 IP Address & Password ...................................................................................................... 25
3.2 Configuring IP Address & Password via console and telnet ................................................ 25
3.3 Configuring IP Address via Web Interface .......................................................................... 26
3.4 Reference Manuals for Web, Console, Telnet Management ............................................... 28
3.5 Configuration for SNMP Management ................................................................................ 29
3.6 SNMP MIBs........................................................................................................................ 30
SF71060M & SF71060MP
Revision A3
0B1. Introduction
The SF71060M & SF71060MP switches are Industrial 10/100/1000Base managed switches featuring:
Eight 10/100/1000Mbps copper ports
Two dual-speed SFP slots for 100Base-FX or 1000Base-X
Model Definitions
Model
Copper
ports
SFP slots
PoE PSE
function
Power via
DC input
Powered via
PoE capable
Software
managed
SF71060M
8
2 dual-speed
-
SF71060MP
8
2 dual-speed
4 PSE ports
-
SF71060M & SF71060MP
Revision A3
1.1 Features
Eight 10/100/1000Mbps RJ-45 and two dual-speed SFP slots
All copper ports support auto-negotiation and auto-MDI/MDI-X detection.
Two SFP slots support dual speed for 100BASE-FX and 1000BASE-X SFP modules.
Full wire speed forwarding
Supports 802.3x flow control for full-duplex and backpressure for half-duplex
Port link aggregation function with LACP support
Supports SFP with Digital Diagnostic Monitoring (DDM)
Alternatively powered via PoE if direct DC power not available
Optional four 802.3at-compliant PoE+ PSE ports
SNMP private MIB for DDM status, reboot, TFTP firmware update (MIB file Rev1.05 or up)
Optical Power Alarm (OPA) function
Auto Laser Shutdown (ALS) function (supported in H/W Ver.E up)
Management:
- HTTP/HTTPS/SSHv2/CLI telnet/CLI console/SNMP v1/v2c/v3/RMON
- DHCP/DHCPv6 client, DHCP relay, DNS client, NTPv4
- IPv6 support, System Syslog, Configuration down/upload, Software upload
Security:
- NAS, 802.1X, MAC-based/Web/CLI authentication
- IP MAC binding, TACACS+, IP source guard
Layer 2:
- QoS, 802.1Q/MAC-based/Protocol-based/Private/IP subnet VLAN, Port Isolation
- Storm control for UC/MC/BC packets, Static MAC configuration
- IGMP v2/v3 snooping, MLD v1/v2 snooping, DHCP snooping
- Multiple Spanning Tree - MSTP. RSTP, STP
Auto Multi-Ring (KAMR) Technology:
- Fast failover response time, Auto recovery when failure is repaired
- Supports up to five redundant rings, Works with RSTP network
SF71060M & SF71060MP
Revision A3
1.2 Product Panels
The following figure illustrates the front panel and rear panel of the switch:
SF71060M Front panel
SF71060MP Front panel
SF71060M & SF71060MP
Revision A3
154BUpper panel
1.3 LED Indicators
LED
Function
PWR
Power status
Mgt.
Management status
Port 1~ 8 SPEED LEDs Speed & PoE status
Port 1~ 8 LINK LEDs
Link & activity status
SFP 9, 10 LED
Speed & link & activity status of SFP port
1.4 Specifications
10/100/1000 Copper Ports (Port 1 ~ Port 8)
Compliance
IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3u 1000Base-T
Connectors
Shielded RJ-45 jacks
Pin assignments
Auto MDI/MDI-X detection
Configuration
Auto-negotiation or software control
Transmission rate
10Mbps, 100Mbps, 1000Mbps
Duplex support
Full/Half duplex
Network cable
Cat.5 UTP
Dual-speed SFP Slots (Port 9, Port 10)
Compliance
IEEE 802.3u 100Base-FX
IEEE 802.3z 1000Base-SX/LX (mini-GBIC)
Connectors
SFP slots for optional SFP fiber modules
SF71060M & SF71060MP
Revision A3
Configuration
Auto 1000Mbps, Full duplex
Forced 100Mbps, Full duplex
Transmission rate
100Mbps and 1000Mbps
Network cables
MMF 50/125 60/125, SMF 9/125
Eye safety
IEC 825 compliant
Console Port
Interface
RS-232, DTE type
Connector
Shielded RJ-45
Switch Functions
MAC Addresses Table
8K entries
Forwarding & filtering
Non-blocking, full wire speed
Switching technology
Store and forward
Maximum packet length 9.6K bytes
IP Multicast groups
8192 supported
Flow control
IEEE 802.3x pause frame base for full duplex operation
Back pressure for half duplex operation
Power over Ethernet PSE Function (SF71060MP)
PSE Ports
Port 1 ~ Port 4
Power output pins
Positive of power voltage: pin 1,2
Negative of power voltage: pin 3,6
Standard
IEEE 802.3at
Classification
PD Class 0 ~ 4 detection
Power Delivery
30W max. (per port) at port output for Cat.5 distance up to 100 meters
Protection
Under voltage protection
Over voltage protection
Over current detection
Powered via Power over Ethernet (SF71060M)
PD Port
Port 2
PoE Standard
IEEE 802.3af PoE PD (Powered Device)
PSE Support
IEEE 802.3af & 802.3at PSE
Power Classification
Class 3
Input Voltage (Vpoe)
36 ~ 57VDC via Cat.5
SF71060M & SF71060MP
Revision A3
Power reception pins
Positive of PoE power voltage: pin 1,2,4,5
Negative of power voltage: pin 3,6,7,8
Terminal Block Connector
DC power input
Screwed euro terminal block: 2 pairs of +/- contacts
Operating Input Voltages +7 ~ +60VDC (General applications)
+45 ~ +57VDC (PoE applications)
Power consumption
9W max. (Full load with no PoE support)
130W max. (Full load with 4 PoE max. output)
Alarm relay output
2 terminal contacts AR+/AR- (30VDC/1A max. or 120VAC/0.5A max.)
Alarm events
Power failure, Specific port link fault (software configured), OPA
* Warning: The -48VDC power supply is not supported.
856BUMechanical
Dimensions
5.51 x 4.17 x 1.65 inches (H x D x W)
Housing
Enclosed metal with no fan
Mounting
Optional Din-rail mounting or Panel mounting
860BUEnvironmental
Operating Temperature Typical -30℃ ~ +70℃*
Storage Temperature
-40℃ ~ +85℃
Relative Humidity
5% ~ 90% non-condensing
* +60℃ ~ +70℃ with 1m/s air flow
864BUElectrical Approvals
FCC
Part 15 rule Class A
CE
EMC, CISPR11 Class A
Safety / LVD
IEC 60950-1
SF71060M & SF71060MP
Revision A3
1B2. Installation
10B2.1 Unpacking
The product package contains:
One SF71060M or SF71060MP Switch
One console cable
2.2 Safety Cautions
To reduce the risk of bodily injury, electrical shock, fire, and damage to the product, observe the
following precautions.
Do not service any product except as explained in your system documentation.
Opening or removing covers may expose you to electrical shock.
Only a trained service technician should service components inside these compartments.
If any of the following conditions occur, unplug the product from the electrical outlet and replace
the part or contact VERSITRON:
The power cable, extension cable, or plug is damaged.
An object has fallen into the product.
The product has been exposed to water.
The product has been dropped or damaged.
The product does not operate correctly when you follow the operating instructions.
Do not push any objects into the openings of your system. Doing so can cause fire or electric
shock by shorting out interior components.
Operate the product only from the type of external power source indicated on the electrical ratings
label. If you are not sure of the type of power source required, consult VERSITRON or local
power company.
SF71060M & SF71060MP
Revision A3
12B2.3 DIN-Rail Mounting
An optional DIN-rail mounting bracket can be purchased for mounting the switch in an industrial DIN-rail
enclosure.
The steps to mount the switch onto a DIN rail are:
1.
Install the mounting bracket onto the switch as shown below:
2.
128BAttach the bracket to the lower edge of the DIN rail and push the unit upward until the bracket
can clamp on the upper edge of the DIN rail.
3.
Clamp the unit to the DIN rail and make sure it is mounted securely.
SF71060M & SF71060MP
Revision A3
13B2.4 Panel Mounting
An optional panel mounting bracket is available for mounting the switch on a flat surface. The mounting steps
are:
1.
Install the mounting bracket onto the switch as shown below:
2.
1291BScrew the bracket onto the switch.
3.
Screw the switch onto a panel. Three screw locations are shown below:
SF71060M & SF71060MP
Revision A3
14B2.5 Applying Power
Pin Assignments of the terminal block connector
Vdc Positive () input terminal
Vdc Negative () input terminal
Vdc Positive () input terminal
Vdc Negative () input terminal
AR+
Alarm relay output positive () terminal
AR
Alarm relay output negative () terminal
Any of the Vdc+/Vdc- pairs can be used to receive DC power from an external power system. Or, one can be
used to deliver the power received to another switch in a daisy-chain application.
Vdc Input specifications
Applications
Power per PSE port
DC working voltage
General
-
+7V ~ +60VDC
PoE
15.4W max.
+45V ~ +57VDC (Typical 48V)
High power PoE (PoE+)
30W max.
+45V ~ +57VDC (+52V up for 30W)
WARNING: The -48VDC power supply is not supported.
Caution:
Do not apply direct DC IN power and PoE power at the same time.
Unplug DC IN when PoE power is connected.
Disconnect PoE power when DC IN is used.
SF71060M & SF71060MP
Revision A3
Three 2P terminal plugs are provided with the switch. Two of the three plugs are used for Vdc interfaces
respectively. The plug is shown below:
184BPower wires : 24 ~ 12AWG (IEC 0.5~2.5mm2)
Install the power source wires into the plug properly, and then install the terminal plug into the switch. If
daisy-chaining power to another switch device is required, install the power wires and then install the terminal
plug into each switch. Then, use the other Vdc contacts.
Note:
1. Only up to four device units can be daisy-chained to receive power from one main power input source.
2. The maximal length of the power wire is 1 meter.
SF71060M & SF71060MP
Revision A3
15B2.6 Alarm Relay Output
An alarm relay output is provided for reporting failure events to a remote alarm relay monitoring system. The
replay output is provided with two contacts in the terminal block connector next to the Vdc interfaces.
Pin Assignments of the Alarm Relay output
AR+
Alarm relay output positive () terminal
AR
Alarm relay output negative () terminal
Use the provided 2P terminal plug for signal wiring and plug into the AR+/- contacts.
Alarm Events
Input power failure
Specific port link down (The specific ports can be configured by software.)
OPA alarm if optical power is higher than a upper limit setting or lower than a lower limit setting
Relay Logic
Normal: AR+ and AR- shorted
Alarm: AR+ and AR- open
Note: Be sure the voltage applied on AR+/- contacts is within the specification of 30VDC/1A max. or
120VAC/0.5A max.
SF71060M & SF71060MP
Revision A3
2.7 Powered via PoE over Cat.5 (SF71060M)
Port 2 is equipped with the function of receiving power from a connected PoE PSE device over Cat.5 cable.
The remote PoE PSE devices can be a mid-span PoE injector or end-span PoE switch.
The switches can support the following PSE:
802.3af compliant PSE (Typical, Type 1 PSE)
Possible voltages received: +36 ~ +57VDC
802.3at compliant PSE (High power PoE, Type 2 PSE)
Possible voltages received: +42.5 ~ +57VDC
2.8 Reset Button
The reset button is used to perform a reset of the switch. It is not used in normal cases and can be used for
diagnostic purposes. If any network problem is suspected, it is useful to push the button to reset the switch
without turning off the power. Check whether the network has recovered.
The button can also be used to restore the software configuration settings to factory default values.
The operations are:
Operation
Function
Press the button and release during switch operation
Reset & boot up the switch. The behavior is
same as power boot procedure.
Press the button until MNGT-LED is steady ON
Boot & restore all factory default settings
SF71060M & SF71060MP
Revision A3
2.9 Making UTP Connections
The 10/100/1000 RJ-45 copper ports support the following connection types and distances:
Network Cables
10BASE-T:
2-pair UTP Cat. 3, 4, 5 , EIA/TIA-568B 100-ohm
100BASE-TX:
2-pair UTP Cat. 5, EIA/TIA-568B 100-ohm
1000BASE-T:
4-pair UTP Cat. 5 or higher (Cat.5e is recommended), EIA/TIA-568B 100-ohm
Link distance:
Up to 100 meters for all above
Auto MDI/MDI-X Function
This function allows the port to auto-detect the twisted-pair signals and adapts itself to form a valid MDI to
MDI-X connection with the remote connected device automatically. No matter if a straight through cable or
crossover cable is connected, the ports can sense the receiving pair automatically and configure itself to match
the rule for MDI to MDI-X connection. It simplifies the cable installation.
Auto-negotiation Function
The ports are featured with the auto-negotiation function and full capability to support connection to any
Ethernet devices. The port performs a negotiation process for the speed and duplex configuration with the
connected device automatically each time a link is being established. If the connected device is also
auto-negotiation capable, both devices will come out with the best configuration after the negotiation process.
If the connected device is incapable in auto-negotiation, the switch will sense the speed and use half duplex for
the connection.
Port Configuration Management
For making proper connection to an auto-negotiation incapable device, it is suggested to use port control
function via the software management to set forced mode and specify the speed and duplex mode which match
the configuration used by the connected device.
SF71060M & SF71060MP
Revision A3
2.10 Making Fiber Connection
The dual-speed SFP slots, Port 9 and Port 10 must be populated with a fiber optic SFP module for making fiber
connections.
Types of fiber optic SFP module supported:
1000Mbps based 1000BASE-X
100Mbps based 100BASE-FX
Installing the fiber optic SFP module:
1. Turn off the power to the switch.
2. Insert the fiber optic SFP module into the SFP slot until the module securely seated slot and place
the bail in lock position.
Connecting Fiber Cables
LC connectors are commonly equipped on most fiber optic SFP modules. Identify TX and RX
connector before making cable connection. The following figure illustrates a connection example
between two fiber ports:
Make sure the Rx-to-Tx connection rule is followed on the both ends of the fiber cable.
SF71060M & SF71060MP
Revision A3
Network Cables
Multimode (MMF) - 50/125, 62.5/125
Single mode (SMF) - 9/125
Port Speed Configuration
There are three options for configuring port speed via the software for SFP Port 9 and Port 10.
The options are:
Auto
Auto-detection for the type of the installed SFP transceiver by reading DDM data
100Mbps transceiver: Non-auto-negotiation (forced), 100Mbps, full duplex
1000Mbps transceiver: Auto-negotiation, 1000Mbps, full duplex
100Mbps FDX
Non-auto-negotiation (forced), 100Mbps, full duplex
1Gbps FDX
Auto-negotiation, 1000Mbps, full duplex
SF71060M & SF71060MP
Revision A3
2.11 Making PoE PSE Connections (SF71060MP)
This section describes how to make a connection between an SF71060MP PSE port and a PoE PD device.
To make a PoE connection, the following check points should be noted:
1. For safety reasons, the connected PoE PD (Powered Device) must be a IEEE 802.3at or IEEE
802.3af-compliant device. Incompliant devices are not supported by the SF71060MP.
2. The Cat.5 cables used for the connections must be 4-pair cables. The power is sent over the spare pairs (4,5)
(7,8) of the cable. The maximum distance supported is 100 meters.
3. The power voltage supplied to the switch must be within the range as specified in section 2.5 to make the
PoE function work.
The PSE ports are equipped with the following capabilities:
1. Detection for an IEEE 802.3af /802.3at compliant PD.
2. No power is supplied to a device which is classified non-IEEE 802.3af compliant PD.
3. No power is supplied when no connection exists on the port.
4. The power is cut off immediately from powering condition when a disconnection occurs.
5. The power is cut off immediately from powering condition when overload occurs.
6. The power is cut off immediately from powering condition when over-current occurs.
7. The power is cut off immediately from powering condition when short circuit condition occurs.
The figure below illustrates a connection example:
SF71060M & SF71060MP
Revision A3
1306B2.12 LED Indication
LED
Function
Color
State
Interpretation
PWR
Power status
Green
ON
Power is supplied to the switch.
OFF
P is not supplied to the switch.
Mgt.
Management status
Green
OFF
The switch is in initialization and diagnostics.
Yellow BLINK Initialization completed with diagnostic error
or system error found during normal operation
Green
ON
Initialization completed with no error
Port 1 ~ Port 8
SPEED_LED Port speed status
Green
ON
Speed is 1000Mbps.
Yellow ON
Speed is 10Mbps or 100Mbps.
BLINK PoE power is on.
LINK_LED
Port link status
Green
ON
Port link is established. (No traffic)
Green
BLINK Port link is up and there is traffic.
OFF
Port link is down.
Port 9 ~ Port 10
Speed _LED
Port speed/link status Green
ON
A 1000Mbps link is established.
Yellow ON
A 100Mbps link is established.
BLINK Activity status
OFF
Port link is down.
SF71060M & SF71060MP
Revision A3
2.13 Making Console Connection
The connector designed for the console port is an RJ-45.
Pin Assignments:
Pin
RS-232 signals
IN/OUT
1,2,7,8
NC
3
RxD
IN
6
TxD
OUT
4,5
GND
Baud Rate information:
Baud rate - 115200
Data bits - 8
Parity - None
Stop bit - 1
Flow control – None
SF71060M & SF71060MP
Revision A3
3. Manage the Switch
The switches provide the following methods to configure and monitor the switch:
Out of band telnet CLI management via the console port
In-band management via telnet CLI over TCP/IP network
In-band management via web interface over TCP/IP network
In-band SNMP management over TCP/IP network
3.1 IP Address & Password
The IP Address is an identification of the switch in a TCP/IP network. Each switch should be designated a new
and unique IP address in the network. The switch is shipped with the following factory default settings for
software management:
Default IP address of the switch: 192.168.0.2 / 255.255.255.0
The switch uses local authentication instead of RADIUS authentication with factory defaults:
Fixed Username: admin
Default password:
No password is required with the factory default. However, the password is used for local authentication in
accessing the switch via the console, telnet and Http web-based interface. For security reasons, it is
recommended to change the default settings for the switch before deploying it to your network.
3.2 Configuring IP Address & Password via console and telnet
[IP Address] setting command is in IP command group.
>IP Setup [] [] [] []
Parameters:
: IP address (a.b.c.d)
: IPv4 subnet mask (a.b.c.d)
: IPv4 router (a.b.c.d)
: VLAN ID (1-4095)
[IPv6 Address] setting command is also in the IP command group.
SF71060M & SF71060MP
Revision A3
>IP IPv6 Setup [] [] []
Parameters:
: IPv6 address is in 128-bit records represented as eight fields of up to four hexadecimal
digits with a colon separates each field (:).
: IPv6 subnet mask
: IPv6 router
[Password] setting command is also in Security/Switch/Users command group.
Security Switch Users Configuration
Security Switch Users Add
Security Switch Users Delete
Refer to “Operation manual for telnet and console management”.
3.3 Configuring IP Address via Web Interface
Start Web Browser
Start your browser software and enter the default IP address of the switch to which you want to connect. The IP
address is used as the URL for the browser software to search the device.
URL: http:/192.168.0.2/
Login to Switch Unit
When the browser software connects to the switch successfully, a Login screen is provided for you to login into
the device as shown below:
SF71060M & SF71060MP
Revision A3
Enter the following default values in the login page:
Default username: admin
Default password:
No password is required.
Click OK to login into the switch.
Web Page after a Successful Login:
Select [Configuration] -> [System] -> [IP] to configure IP address
SF71060M & SF71060MP
Revision A3
Configuration
Description
DHCP Client
Enable the DHCP client by checking this box.
IP Address
Provide the IP address of this switch unit.
IP Mask
Provide the IP mask of this switch unit.
IP Router
Provide the IP address of the default router for this switch unit.
VLAN ID
Provide the managed VLAN ID. The allowed range is 1 through 4095.
DNS Server
Provide the IP address of the DNS Server in dotted decimal notation.
DNS Proxy
When DNS proxy is enabled, DUT will relay DNS requests to the current configured
DNS server on DUT, and reply as a DNS resolver to the client device on the network.
Save
Click to save the changes.
Reset
Click to undo any changes made locally and revert to previously saved values.
Renew
Click to renew DHCP. This button is only available if DHCP is enabled.
3.4 Reference Manuals for Web, Console, Telnet Management
The following manuals are also available separately for Console, Telnet and Web management:
Operation manual - telnet & console management xxxxxx.doc
Operation manual - web management xxxxx.doc
The manuals describe the detailed commands and information.
SF71060M & SF71060MP
Revision A3
3.5 Configuration for SNMP Management
The switch supports SNMP v1, SNMP v2c, and SNMP v3 management. Make sure the related settings are
well-configured for the switch before you start the SNMP management from an SNMP manager.
Using Telnet Interface
The following are available commands in telnet SNMP command group to configure SNMP-related settings:
>SNMP Configuration
>SNMP Mode [enable|disable]
>SNMP Version [1|2c|3]
>SNMP Read Community []
>SNMP Write Community []
>SNMP Trap Mode [enable|disable]
>SNMP Trap Version [1|2c|3]
>SNMP Trap Community []
>SNMP Trap Destination []
>SNMP Trap IPv6 Destination []
>SNMP Trap Authentication Failure [enable|disable]
>SNMP Trap Link-up [enable|disable]
>SNMP Trap OPA [enable|disable]
>SNMP Trap Inform Mode [enable|disable]
>SNMP Trap Inform Timeout []
>SNMP Trap Inform Retry Times []
>SNMP Trap Probe Security Engine ID [enable|disable]
>SNMP Trap Security Engine ID []
>SNMP Trap Security Name []
>SNMP Engine ID []
>SNMP Community Add [] []
>SNMP Community Delete
>SNMP Community Lookup []
>SNMP User Add [MD5|SHA] [] [DES] []
>SNMP User Delete
>SNMP User Changekey []
>SNMP User Lookup []
>SNMP Group Add
>SNMP Group Delete
>SNMP Group Lookup []
SF71060M & SF71060MP
Revision A3
>SNMP View Add [included|excluded]
>SNMP View Delete
>SNMP View Lookup []
>SNMP Access Add [] []
>SNMP Access Delete
>SNMP Access Lookup []
Using Web Interface:
The commands supports configuration for:
-
Basic system configuration for SNMP v1 and SNMP v2c
-
Basic system configuration for SNMP v1 trap, SNMP v2c trap and SNMP v3 trap
-
Communities that permit to access to SNMPv3 agent
-
USM (User-based Security Model) user table for SNMPv3
-
VACM (View-based Access Control Model) Viewer table for SNMPv3
-
Group table for SNMPv3
-
Accesses group table for SNMPv3
3.6 SNMP MIBs
The switch provides the following SNMP MIBs:
- RFC 1213 - MIB II
- RFC 2674 - QBridge MIB (VLAN MIB)
- RFC 2819 - RMON (Group 1, 2. 3 & 9)
- RFC 2863 - Interface Group (IF) MIB
- RFC 3411 - SNMP Management Frameworks
- RFC 3414 - User Based Security Model (USM)
- RFC 3415 - View Based Access Control Model (VACM)
- RFC 3621 - Power Ethernet MIB
- RFC 3635 - EtherLike MIB
- RFC 3636 - 802.3 Medium Attachment Units (MAUs) MIB
- RFC 4133 - Entity MIB
SF71060M & SF71060MP
Revision A3
- RFC 4188 - Bridge MIB
- RFC 4668 - RADIUS Authentication Client MIB
- RFC 5519 - Multicast Group Membership Discovery (MGMD) MIB
- IEEE 802.1 MSTP MIB
- IEEE 802.1AB LLDP MIB
- IEEE 802.1X Port Access Entity (PAE) MIB
- TIA 1057 LLDP Media Endpoint Discovery (MED) MIB
- IEEE 802.1-Q-BRIDGE MIB
- Private SFPDDM MIB
- Private reboot MIB (Remote boot over SNMP)
- Private TFTP firmware update MIB (TFTP Firmware update via SNMP)