Do not obstruct the lens.
4 ft
40 ft
40 ft
25 ft
25 ft
SIDE
VIEW
TOP
VIEW
25 ft
40 ft
180°
Major motion
Minor motion
5 ft
35 ft
35 ft
Quick Start Guide
LMPW-101/102
Digital Lighting Management
PIR Occupancy Sensor
Line
Voltage
Room
Controller
J-Boxes
Daylight Sensor
Switch
LMPW-101
Switch
Corner Mount
Sensor
Ceiling Mount
Sensor
DLM Local Network
Low Voltage
LMRJ Cables
Loads
2
1
Line/Hot
Black wire
Neutral
White wire
Red wire
to Load A (1)
Yellow wire
to Load B (2)
LMRC
102
Room
Controller
J Box
Corner Mount
Occupancy
Sensor
LMPW
Sensor
Switch
To
Load/Line
(Class 1 wiring)
DLM Local Network
(low voltage, Class 2)
LMRJ Cables
CONNECTIVITY
The illustrations below show examples of free-topology wiring. The LMPW communicates
to all other Digital Lighting Management devices connected to the low voltage DLM Local
Network, regardless of their position on the DLM Local Network.
Voltage ...............................................................................24VDC
Current Consumption ............................................................ 8mA
Power Supply .............. Watt Stopper/Legrand Room Controllers
Connection to the DLM Local Network ...................2 RJ-45 ports
DLM Local Network Characteristics:
Provides low voltage power over Cat 5e cable (LMRJ).
Supports up to 24 communicating devices, including 4
LMRC-10x or LMPL-101 max per each DLM Local Network.
Free topology up to 1,000ft of low voltage cable.
Environment ................................................. For Indoor Use Only
Operating Temperature ....................32° to 131°F (0° to 55°C)
Storage Temperature ......................23° to 176°F (-5° to 80°C)
Relative Humidity ...........................5 to 95% (non condensing)
Patent Pending
This unit is pre-set for Plug n’ Go™ operation,
adjustment is optional.
For full operational details, adjustment and more
features of the product, see the DLM System
Installation Guide provided with the DLM room
controllers and also available at www.wattstopper.com
Installation shall be in accordance with all applicable
regulations, local and NEC codes.
To be connected to a Class 2 power source only.
Class 2 Device Wiring Only – Do Not Reclassify and Install
as Class 1, 3 or Power and Lighting Wiring.
Wire connections shall be rated suitable for the wire size (lead and
building wiring) employed.
Do not apply cleaning solvent directly onto unit. Apply cleaning
solvent onto a cloth, then wipe the unit to clean it.
Note: Plus 10° above horizon
MOUNTING
WARNING: Do Not Install To Cover a Junction
Box Having Class 1, 3 or Power and Lighting
Circuits.
BUTTONS AND INDICATORS
Up
Down
Select
Confgure
Button LED
LMPW-101
IR Window
PIR Detection LED
Sensor Binding LED
PIR Lens
Lens Release
Button
On/Off
LMPW-101 LMPW-102
2800 De La Cruz Blvd.
Santa Clara, CA 95050
Phone: 800.879.8585
www.wattstopper.com
Sensor Parameters
Time Delay
20 minutes
Passive Infrared
Sensitivty
90%
Walk Through
OFF
TROUBLESHOOTING
Loads do not operate as expected.
LEDs don’t light, display is off
1.
Check to see that the sensor is connected to the DLM local Network.
2.
Check for 24VDC input to the sensor: Plug in a different DLM device at the sensor location. If the device does
not power up, 24VDC is not present.
• Check the high voltage connections to the room controller.
• If high voltage connections are good and high voltage is present, recheck DLM local Network connections
between the sensor and the room controller.
The wrong lights are controlled
1.
Configure the sensor to control the desired lights using the Push n’ Learn adjustment procedure.
LEDs turn ON and OFF but load
doesn’t switch
1.
Make sure device is not in PnL.
2.
Check load connections to room controller.
WARNING: TO CONNECT A COMPUTER TO THE DLM LOCAL NETWORK USE THE
LMCI-100. NEVER CONNECT THE DLM LOCAL NETWORK TO AN ETHERNET PORT
– DOING SO MAY DAMAGE COMPUTERS AND OTHER CONNECTED EQUIPMENT.
Mounting plate
back view
European
3.5”
Octagon
4” Octagon
4” Square
2 Gang
2 Gang
1 Gang
European
3.5”
Octagon
4” Octagon
4” Square
2 Gang
2 Gang
1 Gang
Using a screwdriver, punch out the
holes for the corresponding junction box.
J-box
Wall
Mounting plate
and base
LMRJ-C8 coupler
(included, LMRJ-S8 splitter optional)
Occupancy
Sensor
Snug
Ring
Wall
Snug
Ring
Secure
Snug
Ring
Loose
Screw
PLUG n’ GO OPERATION (PnG)
Each load is automatically assigned to a switch button.
• If there is only one load it will default to Manual ON/Auto OFF. If there is more than one load then the first load
will default to Auto ON/Auto OFF and the rest of the loads will default to Manual ON/Auto OFF.
• If there are more buttons than there are loads, the extra button(s) do nothing and blink when pressed.
• If there are fewer buttons than there are loads, the last button controls all remaining loads.
UNIT ADJUSTMENT - PUSH n’ LEARN (PnL)
Load Selection Procedure
A configuration button allows access to our patented Push n’ Learn™ technology to change the binding relationship between buttons and loads.
Step 1: Enter Push n’ Learn
Using a pointed tool, press and hold the configuration button for 3 seconds, until the Red LED on the switch begins to blink.
When you release the configuration button, the red LED on other communicating DLM Local Network devices begins to blink.
The DLM Local Network is now in PnL mode. The Red LEDs continue to blink until you exit PnL mode.
All loads in the room turn OFF after entering PnL. After one second, one load turns ON. This is Load #1, which is bound to button #1 as part of the
Plug n’ Go factory default setting. The Blue LED will be ON for all buttons and sensors that are bound to this load.
Step 2: Load selection
Press and release the configuration button to step through the loads connected to the DLM Local Network. As each load turns ON note which
buttons and sensors are showing the blue LED. These devices are currently bound to the load that is ON.
To unbind a button from a load, press the button while its blue LED is ON. The blue LED turns OFF to indicate the button no longer controls the load
that is currently ON. Use the up and down arrow to bind and unbind the sensor.
Pressing the button again while the load is ON rebinds the load to the button and the blue LED illuminates.
Step 3: Exit Push n’ Learn
Press and hold the configuration button until the red LED turns off, approximately 3 seconds.
RELEASING LENS
Insert a small paper clip into the small hole at the top of the trim ring. Press in firmly until the lens is released and springs forward. Grab the lens and
remove it completely to expose the screen.
LCD
Screen
REINSERTING LENS
Reinsert the lens in the proper orientation: place the two posts at the bottom at a 30 degree
angle with the chamfered edge facing up. Gently press the top of the lens until it locks in
place.