Fluke T5-600 Instruction Sheet

Text of the manual

PN 1629509 (English) July 1997, Rev. 2, 9/01

© 2001 Fluke Corporation, All rights reserved. Printed in U.S.A. ® T5-600/T5-1000 Electrical Tester Instruction Sheet W Read First: Safety Information If this product is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. W Warning • Do not use the tester if it is damaged or operating abnormally. Protection may be impaired. • Before each use: • Make sure the battery door is closed and latched. • Inspect the tester and test leads. Look for cracks, missing plastic, exposed metal, or damaged insulation. Replace damaged test leads before using the tester. • Verify the tester’s operation by measuring a known voltage. • Replace the batteries as soon as the low battery indicator (M) appears. • Do not use the tester around explosive gas, vapor or dust. • Do not apply more than the rated voltage, as marked on the tester, between terminals or between any terminal and earth ground. • Refer servicing to qualified personnel. • Use caution when working above 30 V ac rms, 42 V ac peak, or 60 V dc. • When using the probes, keep your fingers behind the finger guards on the probes. • Connect the common test lead before you connect the live test lead. Disconnect the live test lead first. • The display will not display hazardous voltages in display hold. The voltage indicator LED ( ) continues to operate. Symbols � AC (alternating current) � Earth ground � DC (direct current) � Double insulated � Battery � Caution, risk of danger (refer to the manual.) � Caution, shock hazard Voltage Indicator While the tester is on, the LED glows when more than 30 V ac or 60 V dc is present across the leads. (The LED can also glow at lower voltages.) Be aware that such voltages pose a shock hazard. Measuring Voltage (V) The tester automatically selects dc (DC) or ac (AC) voltage mode based on the peak values of the measured signal. The tester defaults to ac voltage when turned on. DC Voltage T5-600 maximum: 600 V CAT III T5-1000 maximum: 1000 V, also 600 V CAT IV AC Voltage 45 Hz to 66 Hz T5-600 maximum: 600 V rms T5-1000 maximum: 1000 V rms, also 600V rms CAT IV DC AC AC/DCV Automatic Selection AC/DCV Automatic Selection ex2.eps

Measuring Continuity and Resistance (Ω)

Continuity Resistance 1000 Ω Range Greater than 400 Ω Open Short Less than 25 Ω ex3.eps Beeper indicates shorts lasting 10 ms (1/100 second) or longer. Measuring AC Current (A) 0.5"(12.9 mm) maximum A AC ex1.eps • Range: 0 A to 100.0 A; 45 Hz to 66 Hz • W Do not connect test probes to voltages while measuring current. • Place conductor anywhere within the sensor zone (shaded area shown below). OK OK OK OK Sensor Zone ex5.eps Display Hold To hold the reading on the display, press and release HOLD. The display will not display hazardous voltages in display hold. The voltage indicator LED ( ) continues to operate. To exit the display hold mode, press and release HOLD again, or turn the rotary switch to a new position. Automatic Power Down The tester turns off automatically if you do not turn the rotary switch or press HOLD for approximately 45 minutes. To resume operation, turn the tester off, then turn the tester on. Low Battery Indicator � W Warning To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the low battery indicator (M) appears. Maintenance Clean the case with a damp cloth and detergent. Do not use abrasives or solvents. Because the inputs are electronically protected, no fuses are required.

Observe the polarity markings inside the battery compartment.

+ + Do not overtighten screw Disconnect probes from Voltage Switch OFF 2 AA + + ex4.eps Replacement Parts Test Lead Assembly. Replace only with Fluke double-insulated leads (T) See "Accessories" for available probes. PN 648029 Battery Door PN 1626588 Battery Door Screw PN 1618578 Accessories H5 Belt Holster TP1 Probe Set, Flat-Blade TP4 Probe Set, 4 mm round Service Information Sheet, PN 686953 To contact Fluke, call: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-678-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Visit Fluke’s Web site at www.fluke.com. Specifications Specifications subject to change without notice. Calibration: One-year calibration cycle. Maximum Voltage Between any Terminal and Earth Ground: T5-600: 600 V rms, Overvoltage Category III; Pollution Degree 2 T5-1000: 1000 V rms, Overvoltage Category III, also 600 V rms overvoltage Category IV, Pollution Degree 2 Maximum Voltage between Current Fork and Earth Ground: T5-600 and T5-1000: 1000 V rms, Overvoltage Category III, also 600 V rms, Overvoltage Category IV, Pollution Degree 2, (This dual rating applies to the current fork only.) Temperature: Operating: -10 °C to +50 °C (14 °F to 122 °F); Storage: -30 °C to +60 °C (-22 °F to +140 °F) Altitude: Operating: 2000 m (6562 ft); Storage: 10,000 m (32808 ft) Relative Humidity: 0 % to 95 %, 5 °C to 30 °C (41 °F to 86 °F); 0 % to 75 %, 30 °C to 40 °C (86 °F to 104 °F); 0 % to 45 %, 40 °C to 50 °C (104 °F to 122 °F) Battery Type and Life: AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride Shock, Vibration: 1 m drop at -10 °C to 50 °C (14 °F to 122 °F) per ANSI/ISA-S82.01-1994 and EN 61010-1: 1995. Random vibration per MIL-PRF-28800F for a Class 2 instrument (5 Hz to 55 Hz, 3 g maximum). Surge Protection: T5-600 6 kV per IEC 61010; T5-1000 8 kV per IEC 61010 Enclosure Rating: IP 52 per IEC 60529, no vacuum applied RF Field Specification: 0.5 % full scale + (specified accuracy) at 3 V / m Safety: Complies with ANSI/ISA-S82.01-94, UL classified to IEC 61010, CSA/CAN C22.2 No.1010.1-92, and EN 61010-1: 1995. EMC: EN 61326 Certifications: In accordance with IEC 61010-1 54CJ

Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C

(64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac- coupled, average responding, and calibrated to the rms value of a sine wave input. Accuracy specifications are given as follows: ± ( [ % of reading] + [number of least significant digits] ) Temperature coefficient of 0.1 x (specified accuracy) / °C for <18 °C or >28 °C (< 64.4 °F or > 82.4 °F) Function T5-600 Range T5-1000 Range Reso- lution Accuracy K 600 V rms 1000 V rms 1 V ± (1.5 % + 2 digits) L 600 V 1000 V 1 V ± (1 % + 1 digit) ? 100.0 A 100.0 A 0.1 A ± (3 % + 3 digits) e 1000 Ω 1000 Ω 1 Ω ± (1 % + 2 digits) Input Protection Function T5-600 T5-1000 Input Impedance (nominal) K 600 V rms 1000 V rms 1 MΩ, <100 pF ac-coupled L 600 V rms 1000 V rms 1 MΩ, <100 pF e 600 V rms 1000 V rms --- Function Open Circuit Test Voltage Short Circuit Current e 1.65 V dc (nominal) <0.6 mA CAT III protects against transients in a fixed equipment installation such as a distribution panel, and lighting systems in large buildings. CAT IV protects against transients from a primary supply such as an electricity meter or an overhead or underground utility service. Limited Warranty & Limitation Of Liability This Fluke product will be free from defects in material and workmanship for two years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, send the defective product to the nearest Fluke Authorized Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. 10/96