Siemens SINUMERIK 840D sl Manual
Read Online
Read the Siemens SINUMERIK 840D sl Manual online using the built-in PDF viewer.
Text of the manual
SINUMERIK 840D sl
NCU
Manual
Applicable to controller
SINUMERIK 840D sl/840DE sl
03/2010
6FC5397-0AP10-3BA0
Preface
Safety Information
1
System overview
2
Application Planning
3
Description
4
Operating and display
elements
5
Interfaces
6
Dimension drawings
7
Mounting
8
Connecting
9
Technical Data
10
Spare Parts/Accessories
11
Appendix
A
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
CAUTION
without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
NOTICE
indicates that an unintended result or situation can occur if the corresponding information is not taken into
account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation for the specific task, in particular its warning notices and
safety instructions. Qualified personnel are those who, based on their training and experience, are capable of
identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be adhered to. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this
publication may be trademarks whose use by third parties for their own purposes could violate the rights of the
owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
GERMANY
Ordernumber: 6FC5397-0AP10-3BA0
Ⓟ 03/2010
Copyright © Siemens AG 2010.
Technical data subject to change
Manual, 03/2010, 6FC5397-0AP10-3BA0
3
Preface
SINUMERIK® Documentation
The SINUMERIK documentation is organized in 3 parts:
● General documentation
● User documentation
● Manufacturer/Service Documentation
Information on the following topics is available at
http://www.siemens.com/motioncontrol/docu:
● Ordering documentation
Here you can find an up-to-date overview of publications.
● Downloading documentation
Links to more information for downloading files from Service & Support.
● Researching documentation online
Information on DOConCD and direct access to the publications in DOConWEB.
● Compiling individual documentation on the basis of Siemens contents with the
My Documentation Manager (MDM), refer to http://www.siemens.com/mdm.
My Documentation Manager provides you with a range of features for generating your
own machine documentation
● Training and FAQs
Information on the range of training courses and FAQs (frequently asked questions) are
available via the page navigation
Target group
This documentation is intended for manufacturers of machine tools, particularly:
● Project engineers, electricians and installers
● Maintenance and service personnel
Benefits
The information in this manual facilitates installation and connection of the SINUMERIK
840D numerical control in the control cabinet.
Standard scope
This documentation only describes the functionality of the standard version. Extensions or
changes made by the machine manufacturer are documented by the machine manufacturer.
Manual, 03/2010, 6FC5397-0AP10-3BA0
Other functions not described in this documentation might be executable in the control.
However, no claim can be made regarding the availability of these functions when the
equipment is first supplied or in the event of servicing.
For the sake of simplicity, this documentation does not contain all detailed information about
all types of the product and cannot cover every conceivable case of installation, operation, or
maintenance.
Technical Support
If you have any technical questions, please contact our hotline:
Europe/Africa
Phone
+49 180 5050 222
Fax
+49 180 5050 223
0.14 €/min. from German landlines, max. 0.42 €/min for calls from a mobile phone
Internet
http://www.siemens.com/automation/support-request
America
Phone
+1 423 262 2522
Fax
+1 423 262 2200
E-mail
[email protected]
Asia/Pacific
Phone
+86 1064 757575
Fax
+86 1064 747474
E-mail
mailto:[email protected]
Note
For technical support telephone numbers for different countries, go to:
http://www.automation.siemens.com/partner
Questions about the documentation
If you have any questions (suggestions, corrections) regarding this documentation, please
fax or e-mail us at:
Fax:
+49 9131 98 2176
E-mail:
mailto:[email protected]
A fax form is available in the appendix of this document.
Manual, 03/2010, 6FC5397-0AP10-3BA0
5
SINUMERIK Internet address
http://www.siemens.com/sinumerik
EC Declaration of Conformity
The EC Declaration of Conformity for the EMC Directive can be found/obtained:
● On the Internet: http://support.automation.siemens.com
under product/order number 15257461
● From the relevant regional office of the I DT MC division of Siemens AG
Convention
Throughout this document, the term "Control Unit" is also used for product designations
NCU 7x0, provided that the technical conditions described are applicable to all variants.
Manual, 03/2010, 6FC5397-0AP10-3BA0
7
Table of contents
Preface ...................................................................................................................................................... 3
1
Safety Information.................................................................................................................................... 11
1.1
Danger notices.............................................................................................................................11
1.2
ESD notices .................................................................................................................................13
2
System overview...................................................................................................................................... 15
2.1
Application....................................................................................................................................15
2.2
System configuration ...................................................................................................................16
2.3
Variants........................................................................................................................................17
3
Application Planning ................................................................................................................................ 19
3.1
Secondary electrical conditions ...................................................................................................19
3.1.1
Protective Separation as per EN 61800-5-1................................................................................19
3.1.2
Grounding concept.......................................................................................................................20
3.1.3
RI suppression measures ............................................................................................................21
3.2
Ambient Climatic and Mechanical Conditions..............................................................................23
3.2.1
Ambient conditions.......................................................................................................................23
3.2.2
Transport and Storage Conditions...............................................................................................24
3.2.3
Operating Conditions ...................................................................................................................26
4
Description............................................................................................................................................... 29
4.1
Features.......................................................................................................................................29
4.2
Illustration.....................................................................................................................................29
4.3
Type plate ....................................................................................................................................32
5
Operating and display elements .............................................................................................................. 33
5.1
Overview of operating and display elements...............................................................................33
5.2
CompactFlash Card.....................................................................................................................34
5.2.1
Properties.....................................................................................................................................34
5.2.2
Inserting the CompactFlash card.................................................................................................35
5.3
LED displays ................................................................................................................................36
5.4
RESET button ..............................................................................................................................37
5.5
7-segment display........................................................................................................................37
5.6
Start-up and mode selector switch ..............................................................................................38
6
Interfaces................................................................................................................................................. 39
6.1
Interface overview........................................................................................................................39
6.2
Power supply X124......................................................................................................................40
6.3
DRIVE-CLiQ interfaces X100 - X105...........................................................................................41
6.4
Ethernet interfaces (X120, X130, X127)......................................................................................42
Table of contents
NCU
8
Manual, 03/2010, 6FC5397-0AP10-3BA0
6.5
PROFINET interfaces, ports 1, 2 ................................................................................................ 45
6.6
PROFIBUS–DP/MPI interfaces X126, X136............................................................................... 47
6.7
Digital inputs/outputs X122 and X132......................................................................................... 48
6.7.1
Pin assignment............................................................................................................................ 48
6.7.2
Technical data............................................................................................................................. 50
7
Dimension drawings ................................................................................................................................ 51
7.1
Dimension drawing...................................................................................................................... 51
8
Mounting.................................................................................................................................................. 53
8.1
Safety information ....................................................................................................................... 53
8.2
Installation types ......................................................................................................................... 54
8.3
Mounting the control unit on the rear wall of the control cabinet ................................................ 56
8.3.1
Mounting control unit using spacers ........................................................................................... 56
8.3.2
Mounting the Control Unit without spacers ................................................................................. 56
8.3.3
Mounting the Control Unit for segregated heat removal............................................................. 58
8.4
Lateral mounting of Control Unit on the SINAMICS drive line-up............................................... 60
9
Connecting .............................................................................................................................................. 61
9.1
Overview ..................................................................................................................................... 61
9.2
Safety information for wiring........................................................................................................ 63
9.3
Opening the front cover............................................................................................................... 63
9.4
Power supply............................................................................................................................... 65
9.4.1
Requirements for the power supply ............................................................................................ 65
9.4.2
Connecting the power supply...................................................................................................... 66
9.5
DRIVE CLiQ components ........................................................................................................... 67
9.5.1
DRIVE-CLiQ wiring ..................................................................................................................... 67
9.5.2
Connectable DRIVE-CLiQ components...................................................................................... 68
9.6
Ethernet....................................................................................................................................... 69
9.7
PROFINET .................................................................................................................................. 69
9.7.1
Wiring PROFINET....................................................................................................................... 69
9.7.2
PROFINET cables....................................................................................................................... 70
9.7.3
Preparing the twisted pair cables................................................................................................ 71
9.7.4
Example PROFINET CBA configuration..................................................................................... 73
9.8
PROFIBUS / MPI ........................................................................................................................ 74
9.8.1
Application................................................................................................................................... 74
9.8.2
PROFIBUS cables and connectors............................................................................................. 74
9.8.3
Connection components in PROFIBUS...................................................................................... 76
9.8.4
Rules for the laying of PROFIBUS cables .................................................................................. 76
9.8.5
Connecting PROFIBUS DP......................................................................................................... 77
9.8.6
Disconnecting stations from the PROFIBUS .............................................................................. 78
9.8.7
Operating the X136 interface as MPI.......................................................................................... 78
9.9
Digital inputs/outputs................................................................................................................... 80
9.9.1
Application................................................................................................................................... 80
9.9.2
Connecting digital inputs/outputs................................................................................................ 82
9.10
USB............................................................................................................................................. 83
9.11
Measuring sockets ...................................................................................................................... 84
Table of contents
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
9
10
Technical Data......................................................................................................................................... 85
11
Spare Parts/Accessories ......................................................................................................................... 87
11.1
Dual fan/ battery module..............................................................................................................87
11.1.1
Application....................................................................................................................................87
11.1.2
Mounting ......................................................................................................................................88
11.2
NX10/15 .......................................................................................................................................90
11.2.1
Description ...................................................................................................................................90
11.2.2
Operating and display elements ..................................................................................................92
11.2.3
Interfaces .....................................................................................................................................93
11.2.4
Dimension drawing ......................................................................................................................97
11.2.5
Mounting ......................................................................................................................................98
11.2.6
Port.............................................................................................................................................100
11.2.7
Technical Data ...........................................................................................................................102
11.3
RS 232C (V.24) module COM01 ...............................................................................................102
11.3.1
Description .................................................................................................................................102
11.3.2
Operator controls and displays ..................................................................................................103
11.3.3
Interfaces ...................................................................................................................................104
11.3.4
Installation/Mounting..................................................................................................................105
11.4
TM15 Terminal Module..............................................................................................................106
11.5
DRIVE-CLiQ Hub Module DMC20.............................................................................................106
11.6
DME20 DRIVE-CLiQ Hub Module .............................................................................................107
11.7
Ordering data .............................................................................................................................107
A
Appendix................................................................................................................................................ 109
A.1
Abbreviations .............................................................................................................................109
A.2
Publication-specific information .................................................................................................110
A.2.1
Feedback on the documentation................................................................................................110
A.2.2
Overview ....................................................................................................................................112
Index...................................................................................................................................................... 113
Manual, 03/2010, 6FC5397-0AP10-3BA0
11
Safety Information
1
1.1
Danger notices
The following notices are intended firstly for your personal safety and secondly to prevent
damage occurring to the product described or any connected devices and machines. Non-
observance of the warnings can result in severe personal injury or property damage.
DANGER
Only appropriately qualified personnel may commission/start-up SINUMERIK equipment.
The personnel must take into account the information provided in the technical customer
documentation for the product, and be familiar with and observe the specified danger and
warning notices.
When electrical equipment and motors are operated, the electrical circuits automatically
conduct a dangerous voltage.
When the system is operating, dangerous axis movements may occur throughout the entire
work area.
A potential fire hazard exists due to the energy being transferred in the equipment and the
work materials used.
All work on the electrical system must be performed after the system has been switched off
and disconnected from the power supply.
DANGER
Proper transportation, expert storage, installation and mounting, as well as careful opera-
tion and maintenance are essential for this SINUMERIK device to operate correctly and
reliably.
The details in the catalogs and proposals also apply to the design of special equipment
versions.
In addition to the danger and warning information provided in the technical customer docu-
mentation, the applicable national, local, and system-specific regulations and requirements
must be taken into account.
Only protective extra-low voltages (PELVs) that comply with EN 61800-5-1 can be connec-
ted to all connections and terminals between 0 and 48 V.
Should it be necessary to test or take measurements on live equipment, then the specifica-
tions and procedural instructions defined in Accident Prevention Regulation VBG A2 must
be adhered to, in particular § 8 "Permissible deviations when working on live components".
Suitable electric tools should be used.
1.1 Danger notices
NCU
12
Manual, 03/2010, 6FC5397-0AP10-3BA0
WARNING
Operating the equipment in the immediate vicinity (< 1.5 m) of mobile telephones with a
transmitting power of > 1 W may lead to incorrect functioning of the devices.
Connecting cables and signal lines should be installed so that inductive and capacitive
interference does not in any way impair the automation and safety functions.
DANGER
Repairs to devices that have been supplied by our company may only be carried out by
SIEMENS customer service or by repair centers authorized by SIEMENS.
When replacing parts or components, only use those parts that are included in the spare
parts list.
EMERGENCY STOP devices EN 60204-1 (VDE 0113 Part 1) must remain active in all
modes of the automation equipment. Resetting the EMERGENCY STOP device must not
cause an uncontrolled or undefined restart.
Anywhere in the automation equipment where faults might cause physical injury or major
material damage, in other words, where faults could be dangerous, additional external
precautions must be taken, or facilities must be provided, that guarantee or enforce a safe
operational state, even when there is a fault (e.g. using an independent limit value switch,
mechanical locking mechanisms, EMERGENCY STOP devices)
1.2 ESD notices
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
13
1.2
ESD notices
CAUTION
The modules contain electrostatically sensitive devices. Discharge yourself of electrostatic
energy before touching the components. The easiest way to do this is to touch a conduc-
tive, grounded object immediately beforehand (for example, bare metal parts of control
cabinet or the protective ground contact of a socket outlet).
NOTICE
Handling ESD-modules:
• When handling electrostatically sensitive devices, make sure that operator, workplace
and packing material are properly grounded.
• Generally, electronic modules must not be touched unless work has to be carried out on
them. When handling PCBs make absolutely sure that you do not touch component pins
or printed conductors.
• Touch components only if:
– You are permanently grounded via an ESD armband
– You are wearing ESD shoes or ESD shoe-grounding-strips, if ESD flooring is
available
• Modules may only be placed on electrically conductive surfaces (table with ESD top,
conductive ESD foam plastic, ESD packaging bags, ESD transport containers).
• Keep modules away from visual display units, monitors or TV sets (minimum distance
from screen 10 cm).
• Do not bring ESD-sensitive modules into contact with chargeable and highly-insulating
materials, such as plastic, insulating table tops or clothing made of synthetic materials.
• Measurements on modules are allowed only if:
– The measuring instrument is properly earthed (e.g., protective conductor) or
– Before measuring with a floating measuring instrument, the probe is briefly
discharged (e.g., touch the bare metal parts of the control housing).
Manual, 03/2010, 6FC5397-0AP10-3BA0
15
System overview
2
2.1
Application
Features
SINUMERIK 840D sl offers modularity, openness, flexibility, and uniform structures for
operation, programming, and visualization. It provides a system platform with trend-setting
functions for almost all technologies.
Integrated into the SINAMICS S120 drive system and complemented by the SIMATIC
S7-300 automation system, the SINUMERIK 840D sl forms a complete digital system that
is best suited for the mid to upper performance range.
The SINUMERIK 840D sl is characterized by:
● A high degree of flexibility
● Excellent dynamic response and precision
● Optimum integration into networks
Integrated and certified SINUMERIK Safety Integrated safety functions are available with
SINUMERIK 840D sl. Consequently, highly effective protection for personnel and machines
is achieved in a simple, economical, and practical manner.
Operating and programming software such as ShopMill or ShopTurn, as well as Motion
Control Information System Products (MCIS-Products) can be used for the production
sector.
Fields of application
The SINUMERIK 840D sl can be used worldwide for turning, drilling, milling, grinding, laser
machining, nibbling, punching, in tool and mold making, for high-speed cutting applications,
for wood and glass processing, for handling operations, in transfer lines and rotary indexing
machines, for mass production and JobShop production.
The SINUMERIK 840DE sl is available as an export version for use in countries requiring an
export authorization.
2.2 System configuration
NCU
16
Manual, 03/2010, 6FC5397-0AP10-3BA0
2.2
System configuration
SINUMERIK 840D sl combines CNC, HMI, PLC, closed-loop control, and communication
tasks within a single NCU (Numerical Control Unit).
Components
For operation, programming, and visualization purposes, the corresponding operating
software is already integrated into the CNC software for the NCU and therefore runs on the
high-performance NCU multi-processor module. For increased operating performance, the
SINUMERIK PCU 50.3 industrial PC can be used.
Up to four distributed OPs can be operated on one NCU/PCU. The operator panel can be
installed as a Thin Client at a distance of up to 100 m.
����������������������������������������
������������������
�����
�������������
������������
������������������
������������
������������
��������������
�������
���������
��������������������
����
���
�����
�����
����������
���������
����
���������
��������
Figure 2-1
Typical topology of the SINUMERIK 840D sl complete system
The following components can be attached to the Control Unit:
● SINUMERIK operator panel front with TCU/PCU 50.3 and Machine Control
Panel/Machine Push Button Panel
● SIMATIC CE panel
● SINUMERIK handheld units
● Distributed PLC I/O via PROFIBUS DP or PROFINET I/O (only applies to NCU 720.2 PN
and NCU 730.2 PN)
● SINUMERIK PP 72/48 peripheral module
● SINUMERIK ADI 4 analog drive interface for four axes
Manual, 03/2010, 6FC5397-0AP10-3BA0
17
● SINAMICS 120 drive system
● Feed and main spindle motors
– 1FT/1FK/1FN/1FW6/1FE1/2SP1 synchronous motors
– 1PH/1PM asynchronous motors
With the NCU 720.2 PN and NCU 730.2 PN, the SINUMERIK 840D sl is offering integrated
PROFINET functionality for the first time.
Supported:
● PROFINET CBA functionality
The CBA functionality integrated in the NCU allows users to modularize machinery and
systems: Rapid real-time communication (up to 10 ms) between the controllers means
that systems lend themselves better to standardization and can be reused or expanded
more easily. Response to customer demands is faster and more flexible and startup is
simplified and speeded up by pretesting at component level.
● PROFINET IO
As part of PROFINET, PROFINET IO is a communication concept that is used to
implement modular, distributed applications. PROFINET IO is based on Industrial
Ethernet and allows distributed field and I/O equipment to be connected to the central
processing unit.
256 PROFINET IO devices can be operated on the NCU as an IO controller.
2.3
Variants
The scalability of the hardware and software – both from a CNC perspective and in terms of
operation – means the SINUMERIK 840D sl can be used in many sectors. The possibilities
range from simple positioning tasks up to complex multi-axis systems.
Application areas and performance
● As many as 6 axes can be implemented on an NCU 710. The NCU 710 can be expanded
by up to 2 NX modules. One possible benefit would be improved servo drive control
performance.
● On the NCU 720/730, the number of axes and/or the performance of the drive controller
can be increased to 31 axes. This is achieved by using the NX10/15 module. The NCU
720/730 can be expanded by up to 5 NX10/15 modules in terms of drive controller
performance and the number of axes.
● Use of an NCU 730 is recommended for maximum dynamics and accuracy in mold
making or in the high speed cutting sector.
● Since it has the highest PLC capacity, the NCU 730.2 PN represents the most advanced
configuration within the SINUMERIK 840D sl range.
Manual, 03/2010, 6FC5397-0AP10-3BA0
The following table shows the essential features of the various Control Units:
Table 2-1
Variants
Property
NCU 710 .2
NCU 720.2/.2 PN
NCU 730.2/.2 PN
DRIVE CLiQ ports
4
6
6
Axes
Up to 6
Up to 31
Up to 31
NX10/15
Up to 2
Up to 3/Up to 5
Up to 3/Up to 5
TCU
Up to 2
Up to 4
Up to 4
Manual, 03/2010, 6FC5397-0AP10-3BA0
19
Application Planning
3
3.1
Secondary electrical conditions
3.1.1
Protective Separation as per EN 61800-5-1
Prerequisite
The complete system includes user interfaces (UIs) and interfaces for servicing, startup and
maintenance.
User interfaces (UIs)
UIs are all the interfaces that are freely accessible to the machine operator without the need
for tools or aids. These user interfaces provide protective separation up to 230 VAC accord-
ing to EN 61800-5-1.
Interfaces for servicing, startup and maintenance
DANGER
The interfaces for servicing/installation and start-up/maintenance purposes are provided
without protective separation.
If necessary, these interfaces can be isolated safely using a supplementary adapter
(insulation voltage 230 V AC). Although these adapters are not included in the Siemens
scope of delivery, you can buy these parts from your local dealer, who will be happy to
advise you.
DANGER
Safe isolation can only be ensured if the system configuration specified below is strictly
adhered to. When installing additional components (e.g. S7-300 FM, IP) with an end user
interface, please make sure that the end user interface has protective separation for at
least 230 VAC.
Note
The components of the drive control comply with EN 61800-5-1 and contain only circuits and
customer terminals with class DVC A voltages and safety isolation from circuits with
dangerous voltages (PELV circuits).
3.1 Secondary electrical conditions
NCU
20
Manual, 03/2010, 6FC5397-0AP10-3BA0
3.1.2
Grounding concept
Components
The SINUMERIK 840D sl system consists of a number of individual components which have
been designed so that the system complies with the appropriate EMC and safety standards.
The individual system components are:
● Numerical Control Unit (NCU)
● Machine Control Panel MCP, Machine Push Button Panel MPP
● Keyboard
● Operator panels (operator panel front + TCU/PCU)
● Distributor box and handheld unit
● S7-300 I/O with IM 153 interface module
Grounding measures
The individual modules are attached to a metal cabinet panel by means of screws. Make
sure that near the screws a low-impedance contact of the Control Unit with the cabinet panel
can be made. Insulating paints at the contact point must be removed. The electronics unit
grounds of the modules are connected to each other via DRIVE-CLiQ.
It is permissible to have a cluster of operator components for ground connection/PA.
Example: The control panel on the swivel arm.
It is sufficient in this instance to connect the ground connections of, for example, the PCU,
TCU, and operator panel front using a cable and to route a shared grounding conductor to
the central ground connection in the control cabinet.
3.1 Secondary electrical conditions
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
21
������
��������������
���������
�����������
������������������
��������
�������������
������������
���
��������
�����������
������
�����������
���
��
���������������������
�����������
�
�
��
��
��
�������������
����������������������������������������������������
�����������
��
��
����
���
��
�������
MB
Shielded signal line with reference ground
M
Motor
G
Encoder
PA
Equipotential bonding conductor
SL
Protective conductor
Figure 3-1
Grounding concept
The following rules apply for external cable cross sections:
● Minimum PA cross section ≥ 10 mm2
● The cable cross section of the central protective conductor is calculated from the cable
cross section of the line connection as follows:
Line connection S (mm2)
Protective conductor SL min. (mm2)
S ≤ 16
S
16 ≤ S ≤ 35
16
S ≥ 35
S/2
Additional references
Configuration Manual, EMC Guidelines
3.1.3
RI suppression measures
In addition to the protective grounding of system components, special precautions must be
taken to ensure safe, fault-free operation of the system. These measures include shielded
signal lines, special equipotential bonding connections, and isolation and shielding
measures.
3.1 Secondary electrical conditions
NCU
22
Manual, 03/2010, 6FC5397-0AP10-3BA0
Shielded signal lines
● For the safe and smooth operation of the system, the specified cables must be used.
Please refer to the chapter titled Connection.
● For digital signal transmission, the shielding must always be connected to the housings at
both ends.
Exception:
If non-Siemens devices are connected (printers, programming devices, etc.), standard
shielded cables grounded at one end can also be used. However, these devices must not
be connected to the controller during normal operation. However, if the system cannot
operate without them, then the cable shields must be connected at both ends.
Furthermore, the non-Siemens device must be connected to the controller via an
equipotential bonding cable.
Cable definitions
● Signal cables (example)
– Data cables (Ethernet, PROFIBUS, sensor cables, etc.)
– Digital inputs/outputs
– EMERGENCY OFF lines
● Load cables (example)
– Low-voltage supply lines (230 VAC, 24 VDC, etc.)
– Supply cables to contactors (primary and secondary circuit)
Rules for routing cables
In order to maximize noise immunity for the complete system (controller, power section,
machine) the following EMC measures must be observed:
● The distance between signal lines and load cables must be maximized.
● If necessary, signal and load cables may cross one another (if possible, at an angle of
90°), but must never be laid close or parallel to one another.
● Only use cables approved by SIEMENS for the signal lines from and to the Control Unit.
● Signal cables may not be routed close to strong external magnetic fields (e.g., motors
and transformers).
● Pulse-loaded HC/HV lines must always be laid completely separately from all other lines.
3.2 Ambient Climatic and Mechanical Conditions
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
23
● If signal lines cannot be routed a sufficient distance away from other cables, they must be
installed in grounded cable ducts (metal).
● The clearance (interference injection area) between the following lines must be kept to a
minimum:
– Signal line and electrical circuit signal line (twisted)
– Signal line and associated equipotential bonding conductor
– Equipotential bonding conductor and protective conductor (routed together)
Note
For more specifications regarding interference suppression measures and connection
of shielded cables, see
References
Configuration Manual, EMC Guidelines
3.2
Ambient Climatic and Mechanical Conditions
3.2.1
Ambient conditions
Observing the ambient conditions
The controller is tested for compliance with the ambient conditions specified below. Fault-
free operation is only ensured if:
● These ambient conditions are maintained when storing, transporting and operating the
equipment.
● Original components and spare parts are used. This applies in particular to the use of
specified cables and connectors.
● The equipment is correctly installed and commissioned.
DANGER
Commissioning is absolutely prohibited until it has been completely ensured that the
machine, in which the components described here are to be installed, is in full
compliance with the provisions of the EC Machinery Directive.
3.2 Ambient Climatic and Mechanical Conditions
NCU
24
Manual, 03/2010, 6FC5397-0AP10-3BA0
Standard requirements
The SINUMERIK 840D sl system components meet the following requirements in terms of
standards:
Long-term storage
EN 60721-3-1
Transport
EN 60721-3-2
Stationary operation
EN 60721-3-3
Assistance and support
Compliance with environmental requirements must be ensured during installation of the
complete system. Please contact your sales representative for assistance and support.
3.2.2
Transport and Storage Conditions
Components in original packaging
The following specifications apply to components in transport packaging:
Table 3-1
Climatic environmental conditions
Transport
Storage
Standard/Class
EN 60721-3-2/2K4
EN 60721-3-1/1K4
Temperature range
-20 ... + 60 ℃
-25 ... + 55 ℃
Temperature change
-40 °C/+30 °C and +70 °C/+15 °C **)
< 0.5 K/min (≙ 30 K/h) *)
Relative humidity
5 ... 95 %
10 ... 100 %
Permissible change in
relative humidity
Max. 0.1 % / min (≙ 6 % / h)
*)
Averaged over 5 min
**) Assuming a direct change in the specified air temperatures
Table 3-2
Test limit values for mechanical environmental conditions during transport/storage
Frequency range
5 ... 9 Hz
Constant deflection
7.5 mm
Vibration
to EN 60068-2-6
Acceleration amplitude
9 ... 200 Hz: 2 g
Acceleration
30 g,
Duration of nominal shock
6 ms
Number of nominal shocks
18 shocks
Shock resistance
to EN 60068-2-27
Shock form
Half-sine
g ≈ 9.81 m/s2 (acceleration due to gravity)
3.2 Ambient Climatic and Mechanical Conditions
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
25
Shipping backup batteries
Backup batteries may only be shipped in the original packaging. No special authorization is
required to ship backup batteries. The lithium content is approximately 300 mg.
Note
The backup battery is classified as a hazardous substance, Class 9, in accordance with the
relevant air-freight transportation regulations.
Storage of backup batteries
Always store backup batteries in a cool and dry place. The batteries have a maximum shelf
life of 10 years.
Rules for handling backup batteries
DANGER
Incorrect handling of backup batteries can lead to a risk of ignition, explosion and
combustion. The stipulations of DIN EN 60086-4, in particular regarding avoidance of
mechanical or electrical tampering of any kind, must be complied with.
● Do not open a battery. Replace a faulty battery only with the same type.
● Obtain replacement batteries from Siemens alone (see Ordering data (Page 107)).
● Always try to return low batteries to the manufacturer or deliver these to a registered
recycling company.
3.2 Ambient Climatic and Mechanical Conditions
NCU
26
Manual, 03/2010, 6FC5397-0AP10-3BA0
3.2.3
Operating Conditions
Climatic ambient conditions
If the specified values cannot be maintained, then a heat exchanger or air conditioner must
be provided.
Table 3-3
Climatic environmental conditions to EN 60721-3-3, Class 3K5
Temperature range
0 ... 55°C
Temperature change
< 0.5 K/min (≙ 30 K/h) averaged over 5 min
Humidity
Relative: 5 to 90% at 25 °C
Absolute: ≤ 25 g/m3
Permissible change in relative
humidity
Max. 0.1 % / min (≙ 6 % / h)
Moisture condensation and
ice formation
Not permissible
Dripping water, spray, splash
water, water jets
Not permissible
Supply air
Without caustic gases, dusts and oils
Atmospheric pressure
106 to 92 kPa or 0 to 1,000 m above sea level
Derating
At altitudes over 1,000 to 4,000 m above sea level, the upper
temperature limit must be reduced by 3.5 °C/500 m.
Table 3-4
Test limit values for mechanical environmental conditions during operation
Frequency band
10 ... 58 Hz
Constant deflection
0.075 mm
Vibration
to EN 60068-2-6
Acceleration amplitude
58 ... 200 Hz: 1 g
Acceleration
5 g
Duration of nominal shock
30 ms
Number of nominal shocks
18 shocks
Shock resistance
to EN 60068-2-27
Shock form
half-sine
g ≈ 9.81 m/s2 (acceleration due to gravity)
Function-impairing gases
Degree of severity 3C2 according to EN60721-3-3
Function-impairing dust
When working in areas where gases, dust and oils may be hazardous to functionality, the
controller must be operated in a control cabinet with a heat exchanger or with suitable supply
air.
Table 3-5
Maximum permissible dust content in the air circulating in the control cabinet
Suspended component
0.2 mg/m3
Deposits
1.5 mg/m2/h
3.2 Ambient Climatic and Mechanical Conditions
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
27
Note
Dust deposits must be removed at regular intervals.
Radio interference
Applicable standards: EN 61800-3
Table 3-6
Limit values for radio interference suppression in industrial environments
Limit class according to EN 61800-3
Conducted radio interference
C3
Radio interference
C3
Note
The user must consider interference radiation for the complete system. Particular attention
should be paid to cabling. Please contact your sales representative for assistance and
support.
If compliance with limit value class C2 is required, please contact your local Siemens sales
partner.
NOTICE
Please see the relevant SINAMICS documentation for EMC notes on how to deal with line
filters and reactors.
NOTICE
The Control Unit is exclusively intended for installation in ESD-protected areas. The CE-
associated ESD interference immunity limit values can only be achieved via installation in
the control cabinet. Only make physical contact using appropriate ESD protective
measures.
3.2 Ambient Climatic and Mechanical Conditions
NCU
28
Manual, 03/2010, 6FC5397-0AP10-3BA0
Manual, 03/2010, 6FC5397-0AP10-3BA0
29
Description
4
4.1
Features
A Control Unit has the following elements:
● Battery-backed real-time clock
● Slot for a CompactFlash Card
● DRIVE-CLiQ interfaces for connecting to the drive
● Interfaces for operation behind a hinged front cover:
– Ethernet ports
– 2 PROFINET interfaces for NCU 720.2 PN and NCU 730.2 PN
– PROFIBUS interfaces
– Digital inputs/outputs (6 of which can be parameterized as inputs for probe and
BERO)
● Commissioning interfaces behind a blanking cover
4.2
Illustration
Control Units without PROFINET
The following figure shows an NCU 730.2 with its interfaces and control and display
elements (fault displays and status indicators). Please ensure that the structure of the NCUs
is virtually identical. There are only a few discrepancies, as follows:
● The NCU 710.2 has 4 rather than 6 DRIVE-CliQ interfaces.
● Deviations with NCU 710.2 and NCU 720.2:
– No cooling fins
– Layout of control and display elements behind the blanking plate (see Chapter
Position of operator control and display elements (Page 33))
Manual, 03/2010, 6FC5397-0AP10-3BA0
�����������
���������������������
��������������
��������
��������������
�����������������
������
�����������
���������
�����������
����������������
������������
������
����������
������������
����������
�����������������
�����������
�����������
�������������
����������������
�����������������
������������������
������
�������������������������
���������������������������������������
���������������
������������
�����������������������
�������������
����
�����������������������
����������
������������
��������
��������������
�������
����������������
������
����
����
����
����
����
����
����
Figure 4-1
Representation of the NCU 730.2
Manual, 03/2010, 6FC5397-0AP10-3BA0
31
Control Units with PROFINET
The following figure shows an NCU 720.2 PN/730.2 PN with its interfaces and control and
display elements (fault LEDs and status indicators).
CAUTION
The PROFINET interfaces of the integrated PLC 319-3 PN/DP are permanently assigned to
the option slot on the "PN NCUs". Forceful removal of the interface module will cause
defects, which can only be repaired at the factory.
�����������
���������������������
��������������
���������������
�������
�����������������
������
���������
�����������
������
����������
����������
�������
�������������
����
�����������
��������������
����������������
�����������������
�������������������
���������������������������������������
�������������������������
������������
��������
���������������������
����������������
������
����������
������������������������
�������������
������������
���������������
�����������������������
����
����
����
��������
����
����
����
����
����
����
���������
��������
������������
����������������
Figure 4-2
Representation of the NCU 720.2 PN/730.2 PN
4.3 Type plate
NCU
32
Manual, 03/2010, 6FC5397-0AP10-3BA0
4.3
Type plate
Side-mounted type plate
The following figure shows you all the information included on the type plate located on the
side of the unit.
������������
�������������
���������
����������
��������������
Figure 4-3
Type plate
You might need to access the information provided on the side-mounted type plate after the
equipment has been mounted. Since the type plate is located on the right-hand side of the
housing, which is the side typically used to connect to the SINAMICS S120 module, we
recommend that you make a note of the serial number of the control unit prior to assembly.
Note
The information contained in each field of the type plate on the current control unit may differ
from the information presented in this manual (for example, a later product version,
approvals and marks that have not yet been issued, etc., may be shown).
Manual, 03/2010, 6FC5397-0AP10-3BA0
33
Operating and display elements
5
5.1
Overview of operating and display elements
NCU 720.2 PN/730.2/730.2 PN
�����������������
������������������������
����
�����������������
�����������������������
�������������������
Figure 5-1
Position of operator control and display elements
Operating and display elements
5.2 CompactFlash Card
NCU
34
Manual, 03/2010, 6FC5397-0AP10-3BA0
NCU 710.2/720.2
�����������������
������������������������
����
�����������������
�����������������������
�������������������
Figure 5-2
Position of operator control and display elements
5.2
CompactFlash Card
5.2.1
Properties
Application
The CompactFlash Card is delivered bootable. It is not supplied with the control unit and
must be ordered as a separate component.
The CompactFlash Card is inserted in the CF plug-in slot (X109 interface).
CAUTION
The CompactFlash Card may only be inserted or removed when the control unit is
disconnected from the power supply.
Data
The CompactFlash Card is mandatory for operation of the control unit.
Operating and display elements
5.2 CompactFlash Card
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
35
As well as the basic software for SINUMERIK and the firmware for SINAMICS, the
CompactFlash Card also contains:
● User data (programs, configuration data, parameter settings)
● Version info (serial number, version, type designation)
● License key This means that the CompactFlash Card can be inserted into another control
unit without requiring a license change.
5.2.2
Inserting the CompactFlash card
Proceed as follows
NOTICE
ESD: you must discharge yourself at the cabinet or ground terminal before touching the
CompactFlash Card.
Please proceed as follows:
1. Switch off the power supply.
2. Gently insert the new CompactFlash Card into the plug-in slot until it clicks into place.
When properly installed, the card does not extend beyond the housing.
3. Switch the power supply on again.
Figure 5-3
Inserting the CompactFlash card
Operating and display elements
5.3 LED displays
NCU
36
Manual, 03/2010, 6FC5397-0AP10-3BA0
5.3
LED displays
Table 5-1
Meaning of LED states
Name
Function
Status
Meaning
Red
There is at least one fault (e.g. RESET, watchdog
monitoring etc. ) or the Control Unit is booting up.
Flashing red/orange
(0.5 Hz)
Error accessing CompactFlash Card
Orange
Accessing CompactFlash Card
Flashing orange (0.5 Hz)
Updating the firmware of the connected DRIVE-CLiQ
components
Flashing orange (2 Hz)
Firmware update is complete for components. Wait for
POWER ON for the components in question.
Green
NC powered up and everything in cyclic mode
RDY
Ready
Flashing green/orange or
red/orange (1 Hz)
LED-supported recognition of connected DRIVE-CLiQ
component is activated: (p0124[0] = 1).
RUN
PLC RUN
Green
PLC ready to operate
STOP
PLC STOP
Orange
PLC stopped
SU/PF
PLC FORCE
Red
FORCE activated
SF
PLC SF
Red
PLC group error
DP1
BUS1 F
Red
PROFIBUS-DP1 group error
DP2
BUS2 F
Red
PROFIBUS-DP2 group error
OPT *)
BUS3 F
Off
The PROFINET system runs correctly; data exchange to all
configured IO devices runs.
Red
•
Bus fault (no physical connection)
•
Incorrect transmission rate
Flashing red
(2 Hz)
•
Failure of a connected I/O device.
•
Incorrect or no configuration.
*) The "OPT" LED is only significant for "PN NCUs".
NOTICE
If all the LEDs are flashing, the PLC must be reset via the mode selector (move switch to
position "3" to reboot).
Note
While the Control Unit is powering up, all LEDs briefly light up orange. You can carry out a
detailed diagnosis using a PG/PC and the operating software.
Operating and display elements
5.4 RESET button
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
37
Additional references
● You can find a detailed description of LED states during power-up in the "NCU Operating
System (IM7)" section of the Basesoftware and Operating Software Commissioning
Manual.
● For information on drive faults and alarms, see also:
SINAMICS S120/S150 List Manual (LH1)
5.4
RESET button
Arrangement
The RESET button is located behind the blanking cover.
Performing a reset operation
The reset operation resets the NCU and forces a new power-up. It is similar to a "Power On
Reset" except that the 24 V power supply does not have to be switched off.
5.5
7-segment display
Displaying messages
The 7-segment display is located behind the blanking plate of the Control Unit. It serves as a
status display during startup and performs the following tasks:
● Output of test and diagnostic messages.
● Output of status messages during booting
Critical messages
● During normal operation, "6" appears here and the dot flashes.
● An "8" indicates that the fan is defective or that the Control Unit is operating without a fan.
Additional references
CNC Commissioning Manual Part 1 (NCK, PLC, drive)
Operating and display elements
5.6 Start-up and mode selector switch
NCU
38
Manual, 03/2010, 6FC5397-0AP10-3BA0
5.6
Start-up and mode selector switch
Layout
The Control Unit has two coding switches in the lower section of the front panel.
● The left switch (labeled SIM/NCK) is the NCK startup switch.
Setting during normal operation: "0"
● The right switch (labeled PLC) is the PLC mode selector switch.
Setting during normal operation: "0"
Figure 5-4
Startup and mode selector switch
Additional references
CNC Commissioning Manual Part 1 (NCK, PLC, drive)
Manual, 03/2010, 6FC5397-0AP10-3BA0
39
Interfaces
6
6.1
Interface overview
Interface overview
Table 6-1
Overview of available external interfaces
Interface
Designation
Plug-connector type
DRIVE-CLiQ (0)
X100
Spec. RJ45 socket
DRIVE-CLiQ (1)
X101
Spec. RJ45 socket
DRIVE-CLiQ (2)
X102
Spec. RJ45 socket
DRIVE-CLiQ (3)
X103
Spec. RJ45 socket
DRIVE-CLiQ (4)
X104 (only NCU 720/730)
Spec. RJ45 socket
DRIVE-CLiQ (5)
X105 (only NCU 720/730)
Spec. RJ45 socket
Ethernet IE1/OP
X120
Standard RJ45 socket
Ethernet IE2/NET
X130
Standard RJ45 socket
Ethernet (service socket)
X127
Standard RJ45 socket
1st PROFINET interface
Port 1 (only "PN NCUs")
Standard RJ45 socket
2nd PROFINET interface
Port 2 (only "PN NCUs")
Standard RJ45 socket
Digital I/Os
X122, X132
Screw terminals, 2x12-pin
24 V power supply
X124
Screw terminals, 4-pin
USB interfaces
X125/X135
USB socket
PROFIBUS DP1
X126
9-pin SUB-D socket
PROFIBUS DP2/MPI
X136
9-pin SUB-D socket
RS232 interface
X140
9-pin SUB D plug connector
Test sockets (T0, T1, T2, and
M)
X131 - X134
Sockets on the circuit board
CompactFlash Card
X109
50-pin socket
Dual fan/battery module
X190
6-pin
Note
For specifications regarding the cables to be connected and the use of interfaces, see the
chapter titled "Connection".
6.2 Power supply X124
NCU
40
Manual, 03/2010, 6FC5397-0AP10-3BA0
6.2
Power supply X124
This interface is provided exclusively for connection of the external power supply.
See Requirements for the power supply (Page 65).
Pin assignment
Table 6-2
Power supply X124
Pin
Signal name
Signal type
Meaning
1
P24
VI
Power supply 24 V
2
P24
VI
3
M
VO
4
M
VO
Ground
Signal type: VI = voltage input;VO = voltage output
Note
The two "+" or "M" terminals are jumpered in the connector. This ensures the 24 V voltage is
looped through.
Position of power supply interface
���������������������������������������������
�������������������������
�
�
Figure 6-1
Power supply interface
6.3 DRIVE-CLiQ interfaces X100 - X105
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
41
6.3
DRIVE-CLiQ interfaces X100 - X105
Properties
● Automatic detection of components
● 24 V/450 mA per DRIVE CLiQ interface is provided for the connection of encoders and
measuring systems
DRIVE-CliQ pin assignment
Table 6-3
DRIVE-CLiQ interface (X100 - X103 or X100 – X105)
PIN
Signal name
Signal type
Meaning
1
TXP
O
Transmit data +
2
TXN
O
Transmit data -
3
RXP
I
Receive data +
4
Reserved, do not use
5
Reserved, do not use
6
RXN
I
Receive data -
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
VO
Voltage supply for DRIVE-CLiQ, 450 mA maximum
B
M (0 V)
VO
Ground to 24 V
Signal type: I = Input; O = Output; VO = Voltage Output
Position of plug connectors
B
A
8
1
Figure 6-2
DRIVE-CLiQ interface
6.4 Ethernet interfaces (X120, X130, X127)
NCU
42
Manual, 03/2010, 6FC5397-0AP10-3BA0
6.4
Ethernet interfaces (X120, X130, X127)
Properties
The interfaces are full duplex 10/100 Mbit Ethernet ports. Both ports are connected as an
Ethernet terminal.
Pin assignment
Table 6-4
Ethernet interfaces X120, X130, X127
Pin
Signal name
Signal type
Meaning
1
TX+
Output
Transmit data +
2
TX-
Output
Transmit data -
3
RX+
Input
Receive data +
4
NC
5
NC
6
RX-
Input
Receive data -
7
NC
8
NC
LED displays
For diagnostic purposes, the RJ45 sockets are each equipped with a green and an orange
LED. This allows the following status information about the respective Ethernet port to be
displayed:
Table 6-5
Ethernet port LED displays
LEDs
Status
Meaning
To
10 or 100 Mbit link available
Green
Off
Missing or faulty link
To
Receive or transmit activity
Orange
Off
No activity
6.4 Ethernet interfaces (X120, X130, X127)
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
43
Position of connectors
The following figure shows the mounting position and designation of the Ethernet connectors
on the module.
�
�
��������������������
�������������
����
����������
Figure 6-3
Position of the Ethernet interfaces
6.4 Ethernet interfaces (X120, X130, X127)
NCU
44
Manual, 03/2010, 6FC5397-0AP10-3BA0
MAC addresses
A type plate for the MAC addresses of the Ethernet interfaces is attached to the front panel
of the Control Unit:
Figure 6-4
MAC addresses of Ethernet interfaces X120, X130, X127
You can see this type plate when you open the front cover of the Control Units without
PROFINET.
6.5 PROFINET interfaces, ports 1, 2
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
45
6.5
PROFINET interfaces, ports 1, 2
Properties
The interfaces are full-duplex 100 Mbit Ethernet ports with an integrated 2-port switch and a
TCP/IP address for the 2 ports.
�����������������������������������
������������������������������
�������
�������
�������
�������
Figure 6-5
Representation of the PROFINET interfaces
NOTICE
NCU system software V2.6 with PLC software V2.7
Ports 1 and 2 are freely available for use, but ports 3 and 4 are deactivated. With PLC
software < V2.7, the full range of options for PROFINET-based communication can only be
guaranteed for port 1.
Pin assignment
Table 6-6
PROFINET interfaces, ports 1, 2
Pin
Signal name
Signal type
Meaning
1
TX+
Output
Transmit data +
2
TX-
Output
Transmit data -
3
RX+
Input
Receive data +
4
NC
5
NC
6
RX-
Input
Receive data -
7
NC
8
NC
6.5 PROFINET interfaces, ports 1, 2
NCU
46
Manual, 03/2010, 6FC5397-0AP10-3BA0
Position of the ports
The 2 ports for the PROFINET connection are in the option slot of NCU 720.2 PN and
NCU 730.2 PN.
LED displays
For diagnostic purposes, the RJ45 sockets are each equipped with a green and an orange
LED. This allows the following status information about the respective PROFINET port to be
displayed:
Table 6-7
PROFINET ports LED displays
Name
Color
Status
Meaning
To
100 MBit link available
Link
Green
Off
Missing or faulty link
To
Sending or receiving
Activity
Orange
Off
No activity
Beneath the ports are 2 LEDs with no specific function.
MAC addresses
A type plate for with the MAC addresses of the PROFINET/Ethernet interfaces is attached to
the front panel of the NCU 720.2 PN and NCU 730.2 PN:
�����������
�������������������
�����������
����
����
����
�������
�����������������
�����������������
�����������������
�����������������
����������
Figure 6-6
MAC addresses of the PROFINET/Ethernet interfaces
6.6 PROFIBUS–DP/MPI interfaces X126, X136
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
47
You can see this type plate when you open the front cover of the NCU 720.2 PN and
NCU 730.2 PN.
See also
PROFINET cables (Page 70)
6.6
PROFIBUS–DP/MPI interfaces X126, X136
Properties
● Isolated RS 485 interface
● Max. data rate 12 Mbaud
● Supports master/slave operation
● PROFIBUS address is set via configuration
● OLPs (6GK1502-1AA00) are not permitted
Note
In addition to the DP (distributed I/Os) protocol, X136 can also transmit the MPI (multi-
point interface) protocol (software-controlled).
Pin assignment for X126, X136
Table 6-8
PROFIBUS DP interfaces (X126, X136)
Pin
Signal name
Signal type
Meaning
1
Nc
-
-
2
M
VO
Ground to P24_SERV
3
2RS_DP
B
RS485 differential signal
4
2RTS_DP
O
Request to Send
5
1M
VO
Ground to 1P5
6
1P5
VO
5 V power supply for bus terminal, external, short circuit-proof
7
P24_SERV
VO
24 V for teleservice, short circuit-proof, 150 mA maximum
8
2XRS_DP
B
RS485 differential signal
9
Nc
-
-
The 1P5 voltage is provided exclusively to supply the bus terminal.
Signal type: VO = Voltage output (power supply) O = Output B = Bidirectional
6.7 Digital inputs/outputs X122 and X132
NCU
48
Manual, 03/2010, 6FC5397-0AP10-3BA0
Position of connectors
The following figure shows the mounting position and designation of the connectors on the
Control Unit.
�
�
�
�
�
�
�
�
����
���
�������
����
Figure 6-7
PROFIBUS DP/MPI interfaces
6.7
Digital inputs/outputs X122 and X132
6.7.1
Pin assignment
Position of connectors
��������������
����������
����������������������
������������������
�
�
�
�
�
�
�
�
�
��
��
��
�
�
�
�
�
�
�
�
�
��
��
��
����
����
Figure 6-8
Digital inputs and digital inputs/outputs (interfaces X122 and X132)
6.7 Digital inputs/outputs X122 and X132
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
49
Pin assignment for X122 and X132
Table 6-9
X122 digital inputs/outputs
Pin
Signal name
Signal type
Meaning
1
DI0
I
Digital input 0
2
DI1
I
Digital input 1
3
DI2
I
Digital input 2
4
DI3
I
Digital input 3
5
M1
GND
Ground for DI0 - DI3 (functionally-separated relative
to M)
6
M
GND
Ground
7
DI/DO8
B
Digital input/output 8
8
DI/DO9
B
Digital input/output 9 (rapid input)
9
M
GND
Ground
10
DI/DO10
B
Digital input/output 10 (rapid input)
11
DI/DO11
B
Digital input/output 11 (rapid input)
12
M
GND
Ground
Signal type: B = Bidirectional; I = Input; GND = Reference potential (ground)
Table 6-10
X132 digital inputs/outputs
Pin
Signal name
Signal type
Meaning
1
DI4
I
Digital input 4
2
DI5
I
Digital input 5
3
DI6
I
Digital input 6
4
DI7
I
Digital input 7
5
M2
GND
Ground for DI4 – DI7 (functionally-separated relative
to M)
6
M
GND
Ground
7
DI/DO12
B
Digital input/output 12
8
DI/DO13
B
Digital input/output 13 (rapid input)
9
M
GND
Ground
10
DI/DO14
B
Digital input/output 14 (rapid input)
11
DI/DO15
B
Digital input/output 15 (rapid input)
12
M
GND
Ground
Note
The digital inputs/outputs are reserved by the system (terminal assignment).
6.7 Digital inputs/outputs X122 and X132
NCU
50
Manual, 03/2010, 6FC5397-0AP10-3BA0
6.7.2
Technical data
Digital inputs on X122/X132
Table 6-11
Technical data of digital inputs X122/X132
Parameter
Values
Voltage
-3 V to 30 V
Typical power consumption
10 mA at 24 V DC
Galvanic isolation
Reference potential is terminal M1 or M2
Signal level (including ripple)
High signal level: 15 V to 30 V
Low signal level: -3 V to 5 V
Signal propagation delays
L → H: 50 μs
H → L: 100 μs
Digital inputs/outputs on X122/X132
Table 6-12
Technical data of the digital inputs/outputs of X122/X132
Parameter
Values
As an input
Voltage
-3 V to 30 V
Typical power consumption
10 mA at 24 VDC
Signal level (including ripple)
High signal level: 15 V to 30 V
Low signal level: -3 V to 5 V
Pins 8, 10 and 11 are "rapid inputs"
Signal propagation delays of inputs/"rapid inputs"
L → H: 50 μs/5 μs
H → L: 100 μs/50 μs
As an output
Voltage
24 V DC
Maximum load current per output
500 mA
Note
An open input is interpreted as "low".
Only "rapid inputs" can be used as inputs for BEROs and probes.
Terminals M1 or M2 must be connected for the digital inputs to work. This can be done as
follows:
Connect the coupled-motion reference ground of the digital inputs, or provide a jumper to
terminal M. (Notice! This removes the galvanic isolation for these digital inputs.)
Manual, 03/2010, 6FC5397-0AP10-3BA0
51
Dimension drawings
7
7.1
Dimension drawing
���
���
����
���
��
��
���
���
���
���
����
�
����
Figure 7-1
Dimension drawing of Control Unit (dimensions in mm)
Manual, 03/2010, 6FC5397-0AP10-3BA0
53
Mounting
8
8.1
Safety information
Open equipment
These modules are open equipment. This means they may only be installed in housings,
cabinets or in electrical service rooms that can be entered or accessed exclusively by means
of a key or tool. Housings, cabinets, or electrical equipment rooms may only be accessed by
trained or authorized personnel. An external fire protection casing is required.
DANGER
The equipment must be deenergized when you mount the Control Unit.
Control cabinet manufacture
Please refer to the SINAMICS documentation for more details.
NOTICE
The 80 mm ventilation spaces above and below the Control Unit must be observed.
If you have any further questions or are looking for particular solutions, you can contact the
Systems Engineering Plant Chemnitz directly.
8.2 Installation types
NCU
54
Manual, 03/2010, 6FC5397-0AP10-3BA0
8.2
Installation types
Prerequisite
The Control Unit is installed in a control cabinet along with the SINAMICS components.
The following prerequisites must be met to install a Control Unit:
● The control cabinet has been installed and wired.
● SINAMICS components should already have been installed and wired (for lateral
mounting).
● Components and tools are available.
Note
The procedures described below for mounting the Control Unit refer to the delivery
condition of the Control Unit: The upper clip is pulled in and the spacers are mounted
(see figure below).
Designs
The Control Unit is compatible with the SINAMICS S120 in booksize format. There are two
possible mounting methods:
● Mounting on the rear wall of the control cabinet
● Lateral mounting on the SINAMICS S120 Line Module
In this type of mounting, the Control Unit is attached to the side wall of the Line Module in
the control cabinet.
As the design of the Control Unit is based on that of the SINAMICS S120 family, please
observe these notes and the corresponding reference documents.
Mounting aids
The Control Unit is designed for mounting in a control cabinet (IP 20 degree of protection in
accordance with general conditions).
Note
Exception: NCU 710.2 and NCU 720.2 have no cutouts for lateral mounting on the
SINAMICS drive line-up.
8.2 Installation types
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
55
�
�
�
�
�
(1)
Spacers for mounting on the rear wall of the control cabinet
(2)
Lugs for mounting directly on the rear wall of the control cabinet (external heat dissipation)
(3)
Cutouts for lateral mounting on SINAMICS drive group
Figure 8-1
Mounting aids
Mounting instructions
A seal can be provided for segregated heat removal on the Control Unit (apart from
NCU 710.2 and NCU 720.2). This enables an air-tight connection to be made between the
Control Unit and the rear wall of the control cabinet, i.e. the cooling fins are located outside
the control cabinet.
8.3 Mounting the control unit on the rear wall of the control cabinet
NCU
56
Manual, 03/2010, 6FC5397-0AP10-3BA0
8.3
Mounting the control unit on the rear wall of the control cabinet
8.3.1
Mounting control unit using spacers
Introduction
Spacers can be used to mount the control unit on a bare-metal highly-conductive rear wall of
a control cabinet. This mounting method should be used if a number of Control Units are
required or if you wish to isolate the Line Module spatially.
Procedure
Use two M5 (M6) screws in the spacers to mount the control unit to back rear wall of the
control cabinet.
8.3.2
Mounting the Control Unit without spacers
Introduction
If you need to disconnect Control Units NCU 710.2 and NCU 720.2 from the Line Module, or
simply wish to do so, you can mount them directly on the rear wall of the control cabinet
without spacers.
Proceed as follows
The Control Unit has a metal clip at the top of the rear panel; when shipped, the clip is
pushed in and secured with three M3 screws (0.8 Nm).
1. Remove the spacers.
2. Loosen the screws and push the clip up until the upper hole extends beyond the housing.
8.3 Mounting the control unit on the rear wall of the control cabinet
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
57
3. Tighten up the three screws on the clip again.
4. Mount the top and bottom of the Control Unit directly on the rear wall of the control
cabinet with two M6 screws (6 Nm).
��������������
������
Figure 8-2
Mounting the Control Unit without spacers
8.3 Mounting the control unit on the rear wall of the control cabinet
NCU
58
Manual, 03/2010, 6FC5397-0AP10-3BA0
8.3.3
Mounting the Control Unit for segregated heat removal
Introduction
If you wish to perform segregated heat removal on the NCUs with cooling fins, the NCUs can
be mounted directly on the rear wall of the control cabinet without spacers.
Prerequisites
● The bushing for the cooling ribs (external heat sink) has been fitted in the rear wall of the
control cabinet.
● Please ensure the area around the seal is both smooth and clean (② please see figure
titled "Panel cutout").
�����������������������������
������������������������������
�������
���
��������
�������
����
��������
�
�
�
Figure 8-3
Panel cutout
8.3 Mounting the control unit on the rear wall of the control cabinet
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
59
Procedure
1. Remove the spacers.
2. Fit the seal around the cooling ribs of the Control Unit.
�����������������������������������
�����������������������������
����������������������
�
�
���
3. Loosen the three M3 screws (0.8 Nm) on the upper clip and push the clip up until the
upper hole protrudes beyond the housing.
4. Tighten up the three screws on the clip again.
5. Mount the top and bottom of the Control Unit with heat sink directly on the rear wall of the
control cabinet using two M6 screws (6 Nm) (① see figure titled "Panel cutout").
See also
Variants (Page 17)
8.4 Lateral mounting of Control Unit on the SINAMICS drive line-up
NCU
60
Manual, 03/2010, 6FC5397-0AP10-3BA0
8.4
Lateral mounting of Control Unit on the SINAMICS drive line-up
Introduction
The Control Unit can also be mounted laterally on the SINAMICS drive line-up, on the side
panel of a SINAMIC S120 Line Module. The required mounting elements are supplied with
the Line Module.
Note
Exception: NCU 710.2 and NCU 720.2 cannot be laterally mounted on the SINAMICS drive
line-up.
Proceed as follows
The Line Module has five mounting elements on the left-hand side. To mount the Control
Unit, proceed as follows:
1. Remove the spacers from the Control Unit.
2. Position the Control Unit on the left-hand side of the Line Module. The mounting fixtures
fit exactly in the five cutouts on the Control Unit.
3. Push the two units together.
4. Press down on the Control Unit until it engages and is securely connected to the Line
Module.
Figure 8-4
SINAMICS group with Control Unit
Manual, 03/2010, 6FC5397-0AP10-3BA0
61
Connecting
9
9.1
Overview
Connection options
The Control Unit has a series of interfaces via which the power supply and the remaining
system components are connected. The front cover on the Control Unit must be open to
make the connections.
● The various SINAMICS components are connected with the Control Unit via DRIVE-
CLiQ.
● Actuators and sensors can be connected to the digital inputs/outputs.
● The Control Units have the following communication options:
– PROFIBUS DP, MPI, Ethernet
– PROFINET with NCU 720.2 PN and NCU 730.2 PN
The following overview shows an example of the various interfaces and their connection
options.
Note
All devices in the SINUMERIK 840D sl and SINAMICS S120 product families appear in
Catalog NC 61. SIMATIC products that can be connected to the Control Unit appear in
Catalog PM 10.
Manual, 03/2010, 6FC5397-0AP10-3BA0
������
������
������
������
��������
��������
���������
��
���������������
���
������
��������
��������
������
�������
���
�����������
�����������
�����������
�����
�������
����������
���������
����������
���������
���������
��������������������
���������������
�����������������
�������������������
����������
���������
��������������
��������������
������������
�������������
����������
�������������
�������������
�����������
���������
�������������������
����������
��������
���������������������
����������
���������������
������������
������������������
���������
�����
�����������������������������
��������������
�������������
����������
������������
������������������
�����������������������������
���������
����������
��������
���������������������
������������������
���
��������
��� ������������������������������������������������
��� ����������������������������������
��� ������������������������������������������������������
�����������������������������������������������
����������������������������
��������������������������������������
�������������������������������������
���������������������������������������������
�����������������������������������������
��������������
�����������������������������
������������
������������������
�������������������
�
�����������
�
�����������
����������������������
������������
�������
����������
����������������������������
���������������
��������������������
�������������
�������������
����������������������
��������
���
�����������
���������������
�����������
�������
���
������������������
��������
����
����
����
����
����
����
����
����
����
����
����
����
����
����
�����
������
����������
����
����
����
����
��������
������
���������
�������������
������������������
������������������
������������������
������������������
�������������
������������������
���������
����������������������
����������������������
����������
���������
������������������
���������������
���������
���������
���������
�������
Figure 9-1
Connection options for a Control Unit
9.2 Safety information for wiring
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
63
9.2
Safety information for wiring
Note the following:
Safety information
DANGER
The system power supply must be disconnected when you wire the control unit.
NOTICE
If your axis grouping contains a Smart Line Module without DRIVE-CliQ (5 kW or 10 kW),
you must assign the Smart Line Module enable signal to digital output X122.1 on the
control unit.
9.3
Opening the front cover
Introduction
The interfaces are concealed behind a front cover. You must remove this cover before you
can wire the interfaces.
A hinge connects the front cover to the front of the housing. Once opened, the cover can be
completely removed. When the front cover is closed (flipped up), it automatically locks into
place by means of a hook on the connector panel.
9.3 Opening the front cover
NCU
64
Manual, 03/2010, 6FC5397-0AP10-3BA0
Procedure
1. Disengage the release hook on the inside of the front cover (the front cover is open and
in the up position).
2. Remove the front cover with a forward motion.
����
�����������
��������������
��������������
Figure 9-2
Removing the front cover
Note
All cables must be routed vertically upwards to the fullest extent possible so that the front
cover can be closed. The front cover is open and in the up position.
9.4 Power supply
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
65
9.4
Power supply
9.4.1
Requirements for the power supply
External 24 V power supply
Power is supplied to the Control Unit by an external 24 V power supply (e.g., SITOP). The
following power consumption values for the Control Units provide a configuration basis for
calculating the 24 V DC power supply.
Table 9-1
Input voltage specification
Parameters
Values
Typ. power consumption 1)
2.0 A
Max. power consumption 2)
8.5 A
1) NCU only (processor, memory, etc.)
2) NCU with full load at all outputs (digital outputs, USB, DRIVE-CliQ, PROFIBUS DP etc.)
Requirements of DC power supplies
DANGER
The DC power supply is always referenced to ground and may not be generated by an
autotransformer.
Final user interfaces are powered via a DC power supply with protective separation per
EN 1800-5-1.
In the case of supply lines > 10 m, protectors must be installed at the device input in order
to protect against lightning (surge).
The DC power supply must be connected to the ground/shield of the Control Unit for EMC
and/or functional reasons. For EMC reasons, this connection should only be made at one
point. As a rule, the connection is provided as standard in the S7-300 I/Os. In exceptional
circumstances when this is not the case, the ground connection should be made on the
grounding rail of the control cabinet; please also refer to /EMC/EMC Installation Guide.
9.4 Power supply
NCU
66
Manual, 03/2010, 6FC5397-0AP10-3BA0
Table 9-2
Requirements of the DC supply
Rated voltage
According to EN 61131-2
Voltage range (average value)
Voltage ripple peak-to-peak
Ramp-up time at power-on
24 VDC
20.4 to 28.8 V DC
5 % (unfiltered 6-pulse
rectification)
Any
Non-periodic overvoltages
Duration of overvoltage
Restoration time
Events per hour
≤ 35 V
≤ 500 ms
≥ 50 s
≤ 10
Transient voltage interruptions
Outage time
Restoration time
Events per hour
≤ 3 ms
≥ 10 s
≤ 10
Additional references
Recommended power supply units and tables for calculating power consumption for
interconnection with SINAMICS S120 modules can be found in the chapter entitled Control-
Cabinet Construction and EMC Booksize in the SINAMICS S120 Booksize Power Units
Manual.
9.4.2
Connecting the power supply
Wiring the screw-type terminal block
The required 24 VDC load current supply is wired to screw-type terminal block X124.
DANGER
The 24 V direct voltage is to be configured as a protective extra low voltage - DVC A or
PELV.
Supply system lines
Table 9-3
Cable specification for X124
Characteristics
Version
Plug-connector type
Screw-type terminals
Connection possibility
Up to 2.5 mm2
Current carrying capacity
Max. 10 A
Max. cable length
10 m
9.5 DRIVE CLiQ components
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
67
Use flexible cables with a cross section of 0.25 to 2.5 mm2 (or AWG 23 to AWG 13) for wiring
the power supply.
If you only use one wire per connection, a ferrule is not required.
You can use ferrules without an insulating collar in accordance with DIN 46228, Form A long
version.
9.5
DRIVE CLiQ components
9.5.1
DRIVE-CLiQ wiring
The components of the SINAMICS S120 drive family and the control unit are interconnected
using DRIVE-CLiQ. When connecting the components, please follow the rules in the
documentation below without exception:
The "Connecting components" section of the "Machine Configuration Guidelines" System
Manual
Cable specification
Table 9-4
Cable specifications for X100 - X103 or X100 – X105
Feature
Specification
Connector type
RJ45 socket
DRIVE-CLiQ standard (inside the control cabinet)
Cable type
MOTION CONNECT (outside the control cabinet)
Max. cable length
70 m
9.5 DRIVE CLiQ components
NCU
68
Manual, 03/2010, 6FC5397-0AP10-3BA0
9.5.2
Connectable DRIVE-CLiQ components
Components
As a rule, all SINAMICS components approved for SINUMERIK can be connected using the
DRIVE-CLiQ interface.
Table 9-5
Components with DRIVE-CLiQ
Component
Description
Active/Smart Line Module,
Booksize
Line Modules provide the central power supply to the DC link.
Single/Double Motor
Module, Booksize
Motor Modules draw their power from the DC link to supply the
connected motors.
NX10/15
Drive expansion module for up to 6 axes
SMC10/20/30
Cabinet-Mounted Sensor Modules are needed when a motor with a
DRIVE-CLiQ interface is not available and when external encoders
are required in addition to the motor encoder.
SME20/25
Measuring systems outside the cabinet can be connected directly to
the Sensor Module External.
DMC20/DME20
DRIVE-CLiQ Hub Modules are used to implement star-shaped
distribution of a DRIVE-CLiQ line.
TM15
The number of available digital inputs and outputs within a drive
system can be expanded with the Terminal Module.
Additional references
● For information on SINAMICS S120 line modules and Motor Modules, please refer to the
– Equipment Manual Booksize Power Units
– Chassis Power Units Equipment Manual
● You can find information on all other modules in the SINAMICS S120 "Control Units and
Additional System Components" Manual.
Manual, 03/2010, 6FC5397-0AP10-3BA0
69
9.6
Ethernet
Application
The following connections can be established via the Ethernet interfaces:
● X120 provides the link to the system network (e.g. operator panels).
● X130 connects the Control Unit to the company network.
● X127 is used for remote diagnostics via teleservice adapter IE.
You can find further details in the following manuals:
– SINUMERIK 840D sl Basesoftware and Operating Software Commissioning Manual
– SIMATIC TS Adapter IE Manual
Cable specification
Table 9-6
Cable specification for X120, X130, and X127
Characteristics
Version
Plug-connector type
RJ-45 jack
Cable type
Industrial Ethernet cable (CAT5)
Max. cable length
100 m
Note
A crossover cable is required for the direct link between the Control Unit and the TCU.
9.7
PROFINET
9.7.1
Wiring PROFINET
Prerequisite
For SINUMERIK 840D sl, a PROFINET system can only be installed with the following
Control Units:
● NCU 720.2 PN
● NCU 730.2 PN
Manual, 03/2010, 6FC5397-0AP10-3BA0
Use
The following communication links can be established via PROFINET interfaces:
● PROFINET CBA:
Communication between controllers as components in distributed systems
● PROFINET I/O incl. PROFINET IRTE-FLEX:
Communication between the PLC used for control and the field devices (no NCK access
to PROFINET I/O)
Cable specification
For PROFINET, you always require a data transmission rate of 100 Mbit/s (Fast Ethernet) in
full duplex mode. For data transfer purposes, you can use twisted-pair copper cables (4-wire,
100Base-T).
Table 9-7
Cable specification for ports 1, 2
Characteristics
Version
Plug-connector type
RJ45 jack *)
Cable type
Industrial Ethernet cable (CAT5)
Max. cable length
100 m
*) Please use the Fast Connect connector as outlined in the chapter titled "PROFINET
cables (Page 70)".
9.7.2
PROFINET cables
Cable and connector types
Note
For connecting PROFINET to the NCU we recommend using a connector with a 145° cable
outlet (IE FC RJ45 plug 145).
Figure 9-3
RJ45 PN connector with a 145°cable outlet
Manual, 03/2010, 6FC5397-0AP10-3BA0
71
Table 9-8
Connector types for PROFINET
Connector
Designation
Order number
IE FC RJ45 plug 145
RJ45 PN connector with angled
exit
6GK1 901-1BB30-0AA0/
6GK1 901-1BB30-0AB0
Table 9-9
Cable types for PROFINET
Cable
Designation
Order number
IE FC Cable GP 2 (Type A)
4-wire, shielded TP installation cable for IE FC
RJ45
6XV1 840-2AH10
IE FC Flexible Cable GP 2
(Type A)
4-wire, shielded flexible TP installation cable
for IE FC RJ45
6XV1 870-2B
IE FC Trailing Cable GP 2x2
(Type C)
4-wire TP installation cable for ground cable
use
6XV1 870-2D
IE FC Trailing Cable 2x2
(Type C)
4-wire shielded TP installation cable for
connection to FC OUTLET RJ45, for ground
cable use
6XV1 840-3AH10
IE FC Marine Cable 2x2
4-wire shielded marine-certified TP installation
cable for connection to FC OUTLET RJ45
6XV1 840-4AH10
9.7.3
Preparing the twisted pair cables
Function
The IE FC RJ45 Plugs are used to install uncrossed 100 Mbit/s Ethernet connections up to
100 m without the use of patches. Crossed cables can also be installed by swapping the
transmit and receive pair in a plug.
Prerequisite
When you set up your PROFINET system, you can cut the AWG 22 twisted pair cable
on-site to the required length, strip it with the Fast Connect Stripping Tool (for Industrial
Ethernet), and fit the Industrial Ethernet FastConnect RJ-45 Plugs using the cut-and-clamp
technique.
Proceed as follows
Contacting of the FC cable versions is simple and reliable with the 4 integrated insulation
displacement contacts.
● When the plug case is open, color markings on the contact cover make it easier to
connect the cores to the insulation piercing connecting devices. The user can check that
contact has been made correctly through the transparent plastic material of the contact
cover.
● The stripped end of the cable is inserted in the raised insulation displacement terminals
and the terminals are then pressed down to ensure reliable contacting of the conductors.
Manual, 03/2010, 6FC5397-0AP10-3BA0
①
�����
������
������
����
Strip the IE FC Cable 2x2 using
a stripping tool and separate out
the cores according to the color
coding on the contact cover of
the FC RJ45 plug.
②
����������
�������������
�����
�����
Open the case cover of the FC RJ45 plug and insert the strands
into their respective end positions according to the color coding.
③
Lower the contact cover so that
the strands are contacted.
④
����
�����
Close the case cover and press
down until it connects with the
plug case below.
⑤
Use a screwdriver to turn the
snap ring 90°. This will ensure
tension and cable grip.
Assigning the installation cables to the pins on the IE FC RJ45 plug
Between the four individually colored wires of the IE FC RJ45 plug pins, the following
assignments are made:
Pin no.
Wire color
Signal name
Meaning
1
yellow
TX+
Transmit data +
2
Orange
TX-
Transmit data -
3
white
RX+
Receive data +
6
blue
RX-
Receive data -
Manual, 03/2010, 6FC5397-0AP10-3BA0
73
Additional references
For more information, please refer to:
● The Industry Mall
● The Catalog IK PI
● The manual titled "SIMATIC NET Twisted Pair and Fiber-Optic Networks" (entry ID:
8763736).
9.7.4
Example PROFINET CBA configuration
The following figure shows a typical system configuration with PROFINET CBA.
�������
������
������
������
��������������
��������������
��������������
���������������������������
���������������������������
���������������������������
������������
�������������
�������������
����
������������
����������������
����������
�����������������
���������������
������
����
����
���
���
������
������������
������������
Figure 9-4
Example PROFINET CBA configuration
9.8 PROFIBUS / MPI
NCU
74
Manual, 03/2010, 6FC5397-0AP10-3BA0
Station name
Module type
Interface
IP address
X120
192.168.200.1
NCU 730.2 PN
Port 1
192.168.200.2
PCU 50.3
X501
192.168.200.5
Central
MPP 483 IE
X20 DHCP server
192.168.200.50...
X120
192.168.200.11
Unit01
NCU 730.2 PN
Port 1
192.168.200.12
Unit02
CPU 319-3 PN/DP
PN P1
192.168.200.22
Unit03
CPU 317-2 PN/DP
PN P1
192.168.200.32
9.8
PROFIBUS / MPI
9.8.1
Application
Connectable devices
The following devices can be connected to the PROFIBUS DP interfaces:
● PG/PC
● S7 controllers with PROFIBUS DP interface
● Distributed I/O
● Drive units with PROFIBUS DP interface (standard slaves)
9.8.2
PROFIBUS cables and connectors
Cable specification
The PROFIBUS cable is 2-wire, twisted, and shielded with defined technical data.
Table 9-10
Cable specification for X126 and X136
Features
Type
Connector type
9-pin SUB-D socket
Cable type
PROFIBUS cable
Max. cable length
100 m for 12 Mbits
9.8 PROFIBUS / MPI
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
75
Table 9-11
Technical data for PROFIBUS cables
Characteristics
Values
Wave impedance
Approximately 135 to 160 Ω (f = 3 to 20 MHz)
Loop resistance
≤ 115 Ω/km
Effective capacitance
30 nF/km
Damping
0.9 dB/100 m (f = 200 kHz)
Permissible conductor cross section
0.3 mm2 to 0.5 mm2
Permissible cable diameter
8 mm + 0.5 mm
Cable lengths and baud rate
The baud rate determines the cable length of a subnet segment.
Table 9-12
Permitted cable length of a subnet segment for specific baud rates
Baud rate
Max. cable length of a segment (in m)
19.6 to 187.5 kbit/s
10001)
500 kbit/s
400
1.5 Mbit/s
200
3 to 12 Mbit/s
100
1) With isolated interface
Longer cable lengths:
If you must realize greater cable lengths than permitted in one segment, you must use
RS 485 repeaters. The maximum possible cable lengths between two RS 485 repeaters
correspond to the cable length of a segment. You can connect up to 9 RS 485 repeaters in
series.
Note that an RS 485 repeater must be counted as a subnet node when determining the total
number of nodes to be connected. This is true even if the RS 485 repeater is not assigned its
own PROFIBUS address.
Connector features
The bus connector is used to connect the PROFIBUS cables to the PROFIBUS DP
interfaces (X126, X136), thus establishing a connection to additional nodes.
Only bus connectors with a 35° cable outlet should be used in order to ensure that the front
cover can be closed.
9.8 PROFIBUS / MPI
NCU
76
Manual, 03/2010, 6FC5397-0AP10-3BA0
9.8.3
Connection components in PROFIBUS
Connection components
Individual nodes are connected by means of bus connectors and PROFIBUS cables.
Remember to provide a bus connector with a programming port at either end of the subnet.
This will give you the option of expanding the subnet if required, for example, for a
programming device.
Use RS 485 repeaters to connect segments or extend cable lengths.
Segments
A segment is a bus line between two terminating resistors. A segment may contain up to
32 odes. In addition, a segment is limited by the permissible cable length, which varies
according to the transmission rate.
Terminating resistor
A cable must be terminated with its own surge impedance to prevent line disturbances
caused by reflections. Activate the terminating resistor at the first and last node on a subnet
or segment. The control unit must be either the first or the last node on the subnet.
Make sure that the stations to which the terminating resistor is connected are always
supplied with voltage during power-up and operation.
9.8.4
Rules for the laying of PROFIBUS cables
Laying of bus cables
During laying of the PROFIBUS cable, you must avoid:
● twisting
● stretching and
● squeezing
9.8 PROFIBUS / MPI
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
77
Supplementary conditions
During laying of the indoor bus cable, you must also consider the following supplementary
conditions (dO = outer diameter of the cable):
Table 9-13
Supplementary conditions for the laying of PROFIBUS cables
Features
Supplementary conditions
Bending radius for a single bend
80 mm (10xdO)
Bending radius (multiple times)
160 mm (20xdO)
Permissible temperature range for cable routing
-5 °C to +50°C
Temperature range for storage and stationary operation
-30°C to +65°C
Additional references
For length codes of prefabricated cables and additional information on PROFIBUS cables,
refer to "Electrical networks" in the PROFIBUS section of the IK PI catalog titled "Industrial
Communication and Field Devices".
9.8.5
Connecting PROFIBUS DP
Introduction
PROFIBUS cables are connected to the X126/X136 interface by means of a bus connector.
Wiring the bus connector
1. Proceed as follows to connect the bus connector:
2. Plug the bus connector into the corresponding interface on the control unit.
3. Screw the bus connector into place.
As the control unit is located at the start or end of a segment, you must switch on the
terminating resistor ("ON" switch setting).
���������������������
�����������
���������������������
������������
��
���
��
���
Figure 9-5
Terminating resistor switched on and off
Note
Make sure that the stations on which the terminating resistor is located are always
supplied with voltage during booting and operation.
9.8 PROFIBUS / MPI
NCU
78
Manual, 03/2010, 6FC5397-0AP10-3BA0
9.8.6
Disconnecting stations from the PROFIBUS
Removing the bus connector
You can remove the bus connector with a looped-through bus cable from the PROFIBUS DP
interface at any time without interrupting data traffic on the bus.
WARNING
Data exchange on the bus can be interrupted!
A bus segment must always be terminated with the terminating resistor at both ends. This
is not the case, for example, if the last node with a bus connector is de-energized. Because
the bus connector takes its voltage from the node, this terminating resistor is ineffective.
Make sure that the nodes at which the terminating resistor is connected are always
energized.
9.8.7
Operating the X136 interface as MPI
Applications
The X136 interface can also be operated as an MPI interface instead of a PROFIBUS DP
interface. The typical (default) baud rate is 187.5 Kbaud. A baud rate of up to 12 MBaud can
be set for communication with other CPUs. It should be noted, however, that a rate of
12 MBaud is not supported by all CPUs (e.g. smaller SIMATIC S7 CPUs).
The following list provides examples of when using MPI (multi-point interface) may prove
effective:
● If a PC/PG with an MPI is being used
● If an MPI-type handheld unit is being used
Operate MPI like PROFIBUS
The information on wiring the connector (terminating resistors) for PROFIBUS and the rules
on the laying of cables for PROFIBUS apply to this interface as well. When carrying out this
procedure, consult the relevant references.
9.8 PROFIBUS / MPI
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
79
Connector features
The bus connector is used to connect the MPI bus cable to the MPI (X136). This enables
you to establish connections to additional nodes (e.g. PG or SIMATIC S7-CPU). Only bus
connectors with a 35° cable outlet should be used in order to ensure that the front cover can
be closed.
MPI bus cable
The PROFIBUS cable specifications apply here as well. Please note the relevant information
on setting up an MPI network.
Setting up an MPI network
Keep in mind the following basic rules when setting up an MPI network:
● When using the interface as an MPI interface, it is not possible to arrange additional
control for a drive in isochronous mode or to connect distributed I/Os to this interface.
● An MPI bus line must be terminated at both ends. This is achieved by activating the
terminating resistor in the MPI connector in the first and last station and deactivating the
other terminating resistors.
● At least one terminator must be supplied with 5 V.
This means that an MPI connector with an activated terminating resistor must be
connected to a device that is switched on.
● Spur lines (cables leading from the bus segment to the node) should be as short as
possible, i.e. < 5 m in length. Unused spur lines should be removed wherever possible.
● Every MPI station must be connected to the bus first and then activated.
To disconnect the station, it must first be deactivated. Then, the station can be removed
from the bus.
● Maximum cable lengths:
– 200 m per bus segment
– 2000 m total length with RS 485 repeaters
9.9 Digital inputs/outputs
NCU
80
Manual, 03/2010, 6FC5397-0AP10-3BA0
9.9
Digital inputs/outputs
9.9.1
Application
Connecting sensors and actuators
Digital inputs and outputs can be used to connect various sensors and actuators to the two
12-pin connectors (X122 and X132) on the front panel.
The following types of digital I/O are used:
● Digital inputs
● Bidirectional digital inputs/outputs
The assignment of I/Os to functions can be parameterized freely by the user. Special
functions, such as probe inputs (rapid inputs only) and cam outputs, can also be assigned to
the inputs/outputs.
The enables for the drive units and/or motors (Line Module, Motor Module) connected to the
control unit can be switched using the digital inputs.
For further information on NCU 7x0 and NX 1x terminal assignment, see:
● The "Communication in the system" section of the "Machine Configuration Guidelines"
System Manual
● The "IBN CNC: NCK, PLC, Drive" Commissioning Manual ("Tips" section)
Access to digital inputs/outputs
Note
The digital inputs/outputs are updated in accordance with the set PROFIBUS bus clock pulse
for SINAMICS Integrated.
9.9 Digital inputs/outputs
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
81
Block diagram
The following figure shows the block diagram for the digital inputs/outputs of a Control Unit.
����
����
�����������������������������
�����������������������
����������������������
���������������
��������������������������
�����������������������
������������������������
�
�������������������
�
�
�
�
��
��
��
��
����
����
�
�
�
�
����
����
����
�
���
�
�
�������
�
�
�
��
��
��
�����������
������������
������������
�
�
����
����
�
�
�
�
����
����
����
�
���
�
�
��������
�
�
�
��
��
��
������������
������������
������������
�
�
������
�
����
�
�
�
�
�
Figure 9-6
Block diagram for digital inputs/outputs
9.9 Digital inputs/outputs
NCU
82
Manual, 03/2010, 6FC5397-0AP10-3BA0
9.9.2
Connecting digital inputs/outputs
Cable specification
Table 9-14
Cable specification for X122 and X132
Characteristics
Specification
Connector type
Screw-type terminals
Connection option
Up to 0.5 mm2
Current carrying capacity
4 A max.
Connecting cables for digital inputs/outputs
The following conditions apply to connecting cables:
● Use flexible cables with a cable cross-section of at least 0.25 mm2
● Ferrules are not required.
Note
To achieve optimum interference suppression, shielded cables must be used to connect
measuring inputs or BEROs.
Tools required
3.5-mm screwdriver or power screwdriver
Wiring digital inputs/outputs
1. Strip 6 mm of insulation from the wires.
2. Wire the digital inputs of the interface for connection of the sensors.
3. Wire the digital outputs of the interface for connection of the actuators.
4. Insert the cable into the corresponding spring-loaded terminal.
Using shielded cables
The following options are available for the shield connection when using shielded cables:
1. Attach the cable shield to a grounded shielding bus immediately after the cable entry
point in the cabinet (strip the insulation off the cable for this purpose).
2. Continue routing the shielded cable as far as the module but do not make a connection to
the shield there.
Manual, 03/2010, 6FC5397-0AP10-3BA0
83
Using a shield connection
1. Remove the fixing bracket.
2. Insert the cable and fasten the fixing bracket.
This figure shows where to attach the cables to the front panel connector and where to apply
the cable interference suppression using the shield connecting element.
��������������
Figure 9-7
Using a shield connection
9.10
USB
The USB interfaces are used exclusively for service purposes, correspond to the norm and
are, therefore, not described in detail here.
Table 9-15
Cable specification for X125 and X135
Characteristics
Versions
Connector type
Double USB socket – type A
Version
USB 2.0
Current carrying capacity
0.5 A per channel
Max. cable length
5 m
Note
The 5 V power supply is designed to be short-circuit proof.
9.11 Measuring sockets
NCU
84
Manual, 03/2010, 6FC5397-0AP10-3BA0
��������������
Figure 9-8
Position of USB interfaces
9.11
Measuring sockets
Application
The test sockets are used to output analog signals. Any interconnectable signal can be
output to any test socket on the control unit.
● Max. output range of the test signal: 0 to 5 V
● Test sockets have to be parameterized before use, as there is no default setting on
delivery.
CAUTION
The test sockets should be used exclusively for servicing purposes.
The measurements may only be carried out by appropriately trained specialists.
Test socket position
�
������������������
���
�����
�������
�
���
�����
�������
�
���
�����
�������
�
���
���������
Figure 9-9
Test socket arrangement
Manual, 03/2010, 6FC5397-0AP10-3BA0
85
Technical Data
10
Table 10-1
General technical data
Safety
Protection class
I (protective conductor) as per EN 61800-5-1
Degree of protection to EN 0529
IP20 or IPXXB with option slot cover or option module inserted
Certifications
CE, cULus
Pollution degree
2
Cooling
Open-circuit-ventilated
Mounting position
Vertical
Mechanical environmental conditions
Transportation (in transportation
packaging)
2M3 according to EN 60721-3-2
Storage
1M2 according to EN 60721-3-1
Table 10-2
Electrical and mechanical data (1)
NCU 710.2
NCU 720.2
NCU 720.2 PN
Main memory
512 MB DRAM
1 MB SRAM
1 GB DRAM
1 MB SRAM
1 GB DRAM
1 MB SRAM
SIMATIC S7 - integrated
PLC 317-2 DP
PLC 317-2 DP
PLC 319-3 PN/DP
Input voltage
24 VDC
24 VDC
24 VDC
Power consumption, max.
170 W
174 W
216 W
Power loss
22 W
25 W
55 W
Dimensions (WxHxD)
50 x 455 x 272 mm
50 x 455 x 272 mm
50 x 455 x 272 mm
Weight, approx.
2.9 kg
2.9 kg
3.8 kg
Table 10-3
Electrical and mechanical data (2)
NCU 730.2
NCU 730.2 PN
Main memory
1 GB DRAM
1 MB SRAM
1 GB DRAM
1 MB SRAM
SIMATIC S7 - integrated
PLC 317-2 DP
PLC 319-3 PN/DP
Input voltage
24 VDC
24 VDC
Power consumption, max.
216 W
225 W
Power loss
55 W
65 W
Dimensions (WxHxD)
50 x 455 x 272 mm
50 x 455 x 272 mm
Weight, approx.
3.6 kg
3.8 kg
Manual, 03/2010, 6FC5397-0AP10-3BA0
87
Spare Parts/Accessories
11
11.1
Dual fan/ battery module
11.1.1
Application
Functions of the dual fan/battery module
The dual fan/battery module can perform the following tasks:
● Cooling the CPU by means of two redundant fans.
● SRAM buffering if the SuperCap is insufficient.
The Control Unit monitors the temperature inside the module and the functioning of the fan.
Fan faults are displayed and can be read out by means of the diagnostic buffer.
● Fan warning: When one of the two fans has ceased to turn.
● Fan fault: When none of the fans turn.
If the software does not respond within approx. 1 minute the components are shutdown
automatically and the status is indicated by means of the red SF LED.
Fans
If natural convection is not sufficient to ensure heat dissipation for the the
NCU 710.2/720.2/730.2, the fans integrated in the dual fan/battery module will be activated
when required.
● After switching the NCU on, the fan will be activated for a brief period (for testing
purposes) before turning itself off again.
● A temperature sensor on the NCU will switch the fan on if the air intake temperature
exceeds approximately 40°C.
● The fans will be switched off when the air intake temperature falls back below approx.
35°C.
● The fan is monitored during operation. In the event of a fault (stalled rotor or running too
slowly) a message is output.
Fans on the following Control Units run permanently:
NCU 720.2 PN and NCU 730.2 PN
NOTICE
The Control Unit cannot be operated without fans, i.e. the Control Unit will not power up if
the dual fan/battery module is not functioning.
11.1 Dual fan/ battery module
NCU
88
Manual, 03/2010, 6FC5397-0AP10-3BA0
Battery
A 3 V lithium battery can be inserted in the dual fan/battery module. The battery is pre-
assembled with an approximately 4 cm long cable with plug connector. The appropriate
mating connector is attached to a small circuit board for connection in the dual fan/battery
module.
Note
Please dispose of used batteries in the specially provided collection points on site. This will
ensure they are reused in the correct manner or treated as special waste.
NOTICE
The backup time of a used type of battery is at least 3 years. Exceeding this backup time
risks loss of data.
11.1.2
Mounting
Position of the dual fan/battery module
�����������������������
�������������
����
�������
������������
��������������
Figure 11-1
Replacing the dual fan/ battery module
11.1 Dual fan/ battery module
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
89
Proceed as follows
Proceed as follows to replace the dual fan/battery module but only observe points 3 and 4 if
you want to replace the battery as well:
1. Gently push the dual fan/battery module backwards (by pressing on the pressure point) to
release the module from its front interlock (snap-in hooks).
CAUTION
Never pull the dual fan/battery module out abruptly without having released the
interlock. This would break the snap-in hooks and you would not be able to reinsert the
module.
2. Tilt the dual fan/battery module forwards at an angle and pull out the plastic guide from
the Control Unit cutout.
3. Remove the battery by first removing the plug connector and then taking out the battery.
4. Connect the cable plug connector of the new battery to the mating connector in the dual
fan/battery module and push the battery in.
�������
���������������
���������������
�����������������������
Figure 11-2
Battery replacement in the dual fan/battery module
5. Tilt the dual fan/battery module forwards at an angle with the open side facing up (battery
visible).
6. Push the plastic guide into the cutouts on the underside of the Control Unit.
7. Tilt the dual fan/battery module up until the front interlock snaps into place.
The electrical connection between the dual fan/battery module and the Control Unit is
established automatically.
NOTICE
To avoid loss of data, the dual fan/battery module must be replaced during operation.
When doing this, observe that the Control Unit can only be operated for a maximum of
1 minute without fans. If this time is exceeded, the Control Unit will shut itself down.
Manual, 03/2010, 6FC5397-0AP10-3BA0
11.2
NX10/15
11.2.1
Description
Properties
Using this module, you can expand the performance of an axis grouping of the
SINUMERIK 840D sl CNC automation system. Each NX10 can control up to 3 additional
axes and each NX15 can control up to 6 additional axes.
The NX10/15 has the following interfaces:
● 4 DRIVE-CLiQ (X100 – X103)
● 4 digital inputs and 4 digital inputs/outputs (X122)
● Power supply (X124)
Manual, 03/2010, 6FC5397-0AP10-3BA0
91
Display
�����������
���������������������
����
����������������������
�������
����
�����������������������
�������
����������
�������
������������
�������������������������������
������
��������������������
�������
����������
���
���
����
���
�
�
Figure 11-3
Representation of NX10/15 (without cover)
Type plate
The NX10/15 module type plate contains basically the same information as the control unit
type plate (see Section 4.4).
Manual, 03/2010, 6FC5397-0AP10-3BA0
11.2.2
Operating and display elements
LED displays
Table 11-1
Description of LEDs on the NX10/15
LED
Color
Status
Description
Off
Electronic power supply outside permissible tolerance range
Steady-light signal
NX10/15 is ready for operation
Green
Blinklight 2 Hz
Writing to CompactFlash Card
Continuous light
At least one fault is pending (e.g., RESET, watchdog monitoring,
basic system fault).
NX10/15 is booting up.
Red
Blinklight 0.5 Hz
Boot fault (e.g., firmware cannot be loaded into the RAM)
Continuous light
Firmware loading into RAM
0.5 Hz flashing light
Unable to load firmware into RAM
RDY,
READY
H1
Orange
2 Hz flashing light
Firmware CRC fault
Off
Electronic power supply outside the permissible tolerance range,
NX10/15 is not ready for operation.
Continuous light
CU_LINK is ready for communication and cyclic communication is
running
Green
0.5 Hz flashing light
CU_LINK is ready for communication and no cyclic communication is
running
DP1,
CU_LINK
H2
Red
Continuous light
At least one CU_LINK fault is present.
CU_LINK not ready for operation (e.g., after POWER ON)
RESET button
The RESET button is on the front of the module under the cover.
NOTICE
When the pushbutton is actuated, the locally connected drive systems are brought to a
standstill with no feedback to the control. In other words, the drive and control run
asynchronously once the drive has successfully booted up.
Manual, 03/2010, 6FC5397-0AP10-3BA0
93
11.2.3
Interfaces
Power supply X124
Table 11-2
Pin assignment for X124
Terminal
Function
Technical specifications
+
Electronics power supply
+
Electronics power supply
M
Electronic ground
M
Electronic ground
Voltage: 24 V DC (20.4 V - 28.8 V)
Current consumption: max. 0.8 A (without load)
Max. current via jumper in connector:
20 A at 55 °C
Max. connectable cross-section: 2.5 mm2
Type: Screw-type terminal
Note
The two "+" and "M" terminals are jumpered in the connector and not in the device. This
ensures that the supply voltage is looped through.
The current consumption increases by the current consumption of DRIVE-CLiQ and the
digital outputs.
DRIVE-CLiQ interfaces X100 - X103
Table 11-3
Characteristics of X100 - X103
Features
Specification
Connector type
DRIVE CLiQ plug connector
DRIVE-CLiQ standard (inside the control cabinet)
Cable type
MOTION CONNECT (outside the control cabinet)
Max. cable length
70 m
Manual, 03/2010, 6FC5397-0AP10-3BA0
Table 11-4
Pin assignment for X100 - X103
Pin
Signal name
Technical specifications
1
TXP
Transmit data +
2
TXN
Transmit data -
3
RXP
Receive data +
4
Reserved, do not use
5
Reserved, do not use
6
RXN
Receive data -
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
Power supply
B
GND (0 V)
Electronic ground
Dust cover for DRIVE-CLiQ interface: Tyco, order no.: 969556-5
X122 Digital inputs/outputs
Table 11-5
Interface characteristics of X122
Characteristics
Specification
Connector type
Screw-type terminals
Connection option
Up to 0.5 mm2
Current carrying capacity
4 A max.
Manual, 03/2010, 6FC5397-0AP10-3BA0
95
Table 11-6
Pin assignment for X122
Terminal
Designation1)
Technical specifications
1
DI 0
2
DI 1
3
DI 2
4
DI 3
5
M1
6
M
Voltage: -3 V to 30 V
Typical current consumption: 10 mA at 24 V DC
Isolation: The reference potential is terminal M1
Signal level (incl. ripple)
High signal level: 15 V to 30 V
Low signal level: -3 V to 5 V
Signal propagation times:
L → H: approx. 50 μs
H → L: approx. 100 μs
7
DI/DO 8
8
DI/DO 9
9
M
10
DI/DO10
11
DI/DO 11
12
M
As input:
Voltage: -3 V to 30 V
Typical current consumption: 10 mA at 24 V DC
Signal level (incl. ripple)
High signal level: 15 V to 30 V
Low signal level: -3 V to 5 V
Terminal numbers 8, 10, and 11 are "rapid inputs"
Signal propagation times for inputs/"fast inputs":
L → H: approx. 50 μs/5 μs
H → L: approx. 100 μs/50 μs
As output:
Voltage: 24 VDC
Max. load current per output: 500 mA continuous short circuit-
proof
1) DI: digital input; DI/DO: Bidirectional digital input/output; M: Electronics ground M1: Reference ground
Note
An open input is interpreted as "low".
The "rapid inputs" can be used for positioning measurement and as probe inputs depending
on the terminal assignment used.
To enable digital inputs (DI) 0 to 3 to function, terminal M1 must be connected. This can be
done as follows:
Connect the coupled-motion ground reference of the digital inputs or provide a jumper to
terminal M. (Notice! This removes the galvanic isolation for these digital inputs.)
Manual, 03/2010, 6FC5397-0AP10-3BA0
���������������
���������������������
����������������������������������
���������������������������
������������������������������
����������������
�����
������
�
�
�
�
��
��
����
����
�
�
�
�
����
����
����
�
���
�
�
�����������
�
�
�
��
��
��
�����������
������������
������������
�
�
������
�
����
�
�
�
�
�
����������������������
Figure 11-4
Block diagram for digital inputs/outputs
Note
The digital inputs/outputs are reserved by the system (terminal assignment).
Manual, 03/2010, 6FC5397-0AP10-3BA0
97
11.2.4
Dimension drawing
Figure 11-5
NX10/15 dimension drawing
Manual, 03/2010, 6FC5397-0AP10-3BA0
11.2.5
Mounting
Mounting aids
����������������������������
������
�����
Figure 11-6
NX10/15 mounting aids
Designs
Basically, the NX10/15 is integrated into the SINAMICS drive line-up in exactly the same way
as the Control Unit (see Chapter 8, Mounting).
● Lateral mounting of NX 10/15 on the SINAMICS drive line-up
● NX 0/15 directly on the rear wall of the control cabinet
Manual, 03/2010, 6FC5397-0AP10-3BA0
99
Preferred call sequence: The NX modules should be inserted between the Line Module and
the control unit.
CAUTION
The 80 mm ventilation spaces above and below the components must be observed.
Mounting an NX10/15 on another NX10/15
Table 11-7
Mounting an NX10/15 on another NX10/15
Opening the cover.
Unscrewing the screw.
The bracket must be moved so that the
pin is in the opening of the bracket.
Tighten the screw.
Manual, 03/2010, 6FC5397-0AP10-3BA0
Mounted bracket.
Closing the cover.
11.2.6
Port
NX10/15 DRIVE-CLiQ topology
NX10/15 components can be connected to the control unit via DRIVE-CLiQ. The following
rules apply to wiring of the NX10/15:
● Only one star topology is permitted between the NX10/15 and the control unit. This
means that only one NX10/15 can be operated per DRIVE-CLiQ port on a control unit.
● DRIVE-CLiQ ports not assigned to NX10/15 can be wired to other DRIVE-CLiQ
components.
● Once an NX10/15 has been connected and configured, you cannot simply insert it into a
different DRIVE-CLiQ port, as the addresses of the integrated drives are set permanently
from the point of view of the PLC. The following table illustrates this relation: