Hussmann M1X-GE Technical Data Sheet
Read Online
Read the Hussmann M1X-GE Technical Data Sheet online using the built-in PDF viewer.
Text of the manual
Technical Data Sheet
P/N 0475009_C
NSF® Certified
March 2007
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Item Part #
Description
Wiring Item #
FAN ASSEMBLIES
4 Ft, 8 Ft & 12 Ft
A.
4W Standard Fan Assembly
(1)
0392457
Fan Motor, Evaporator
(MO.4410101)
0464847
Fan Blade (FB.4780649)
4W Energy Efficient Fan Assembly
(1)
0477653
Fan Motor, Evaporator
(MO.4410544)
0464847
Fan Blade (FB.4780649)
6 Ft Only
A.
4W Standard Fan Assembly
(1)
0392457
Fan Motor, Evaporator
(MO.4410101)
0252116
Fan Blade (FB.4780611)
4W Energy Efficient Fan Assembly
(1)
0477653
Fan Motor, Evaporator
(MO.4410544)
0252116
Fan Blade (FB.4780611)
Item Part #
Description
Wiring Item #
THERMOSTATS
B.
0382028
Standard Non-adjustable
(2)
Defrost Thermostat
(CT.0382028)
C.
Optional Adjustable
Refrigeration Thermostat
(3)
LAMPS AND BALLASTS
None
©2008 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Note: Revision C adds capacity and weight (Page 5).
2 of 5
M1X-GE Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as in. and (mm).
Meat, Delicatessen and Produce
09-2005
NOTE: Case-to-Case Electrical Connections
are made IN FRONT OF SPLASHGUARD.
4 3/4 (120)
Splashguard
31 5/8
(804)
42
(1064)
A
41 1/2
(1054)
3 In.
(77 mm)
Required
Air Gap
Refrigeration
Outlet
Electrical
Stub Up Area
6 x 6
(152x152)
Waste Outlet
Waste Outlet
FRONT
26 1/4
(665)
B
D
8 (203)
4 1/2 (115)
12 1/8 (307)
41 1/2
(1054)
43 7/8
(1114)
C
Wireway
4 3/4 (120)
26 1/2
(673)
4 1/4 (108)
24
(612)
33 1/2
(851)
Electrical
Field
Connection
30 1/4
(768)
M1X
4 ft
6 ft
8 ft
12 ft
General
(A) Case Length (without ends or partitions)
48 3/8 (1229)
72 3/8 (1838)
96 3/8 (2448)
144 1/2 (3670)
(Each end and insulated partition adds 1 1/2 in. (38 mm) to case line up.)
Maximum O/S dimension of case back to front
(includes bumper)
42 (1064)
42 (1064)
42 (1064)
42 (1064)
Back of case to front of splashguard
33 1/2 (851)
33 1/2 (851)
33 1/2 (851)
33 1/2 (851)
Back of case to O/S edge of front leg
30 1/4 (768)
30 1/4 (768)
30 1/4 (768)
30 1/4 (768)
Distance between edges of external legs and center legs
NA
29 1/2 (750)
41 1/2 (1054)
41 1/2 (1054)
Distance between edges of center legs
NA
NA
NA
43 7/8 (1114)
Distance between front legs and splashguard
2 3/4 (70)
2 3/4 (70)
2 3/4 (70)
2 3/4 (70)
Electrical Service (Electrical Field Wiring connection point)
(B) RH End of case to center of stub up area
36 1/4 (921)
60 1/4 (1530)
84 1/4 (2140)
132 3/8 (3363)
Back of case to center of stub up area
24 (612)
24 (612)
24 (612)
24 (612)
Length of electrical wireway
26 1/2 (673)
26 1/2 (673)
26 1/2 (673)
26 1/2 (673)
(C) RH End of case to LH end of wireway
42 1/8 (1070)
66 1/8 (1680)
90 1/8 (2289)
138 1/4 (3511)
Waste Outlets (One each end)
(D) RH End of case to the center of LH waste outlet
36 1/4 (921)
60 1/4 (1530)
84 1/4 (2140)
132 3/8 (3363)
RH End of case to the center of RH waste outlet
12 1/8 (307)
12 1/8 (307)
12 1/8 (307)
12 1/8 (307)
Back O/S of case to center of waste outlets
31 5/8 (804)
31 5/8 (804)
31 5/8 (804)
31 5/8 (804)
Schedule 40 PVC drip pipe
1 1/4 (32)
1 1/4 (32)
1 1/4 (32)
1 1/4 (32)
Refrigeration Outlet
Back of case to center of refrigeration outlet
26 1/4 (665)
26 1/4 (665)
26 1/4 (665)
26 1/4 (665)
RH end of case to center of refrigeration outlet
8 (203)
8 (203)
8 (203)
8 (203)
Wireway
PHYSICAL DATA
Merchandiser Drip Pipe (in.)
1 1/4
Merchandiser Liquid Line (in.)
3/8
Merchandiser Suction Line (in.)
5/8
3 of 5
P/N 0475009_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
43 1/8
(1095)
31 5/8 (804)
4 3/4
(120)
30 1/4 (766)
42 (1064)
33 1/2 (851)
26 1/4 (665)
Electrical
Case to Case
Connections
FAN
C
O
I
L
3 In. (77 mm)
Required
Air Gap
Refrigeration
Outlet
28 5/8
(727)
38 1/4
(972)
15
(381)
17 1/8
(436)
16 1/4
(413)
7 5/8
(194)
9 3/4 (246)
30 (762)
2 1/8
(54)
12 7/8
(327)
32 3/8 (822)
9 1/2 (241)
Dimensions shown as inches and (mm).
Single Deck, 1 Display Level, Glass Front
Impact Excel M1X-GE
Meat, Delicatessen
Pre-cut and Packaged Produce
REFRIGERATION DATA
Note: This data is based on store temperature and
humidity that does not exceed 75°F and 55% R.H.
M1X-GE
Discharge Air (°F)
26
Evaporator (°F)
18
Unit Sizing (°F)
16
Btu/hr/ft
M1X-GE
Parallel
415
Conventional
440
DEFROST DATA
M1X-GE
Frequency (hr)
6
Defrost Water (lb/ft/day)
2
(± 15% based on case configuration and
product loading).
OFFTIME
M1X-GE
Temp Term (°F)
43°F
Failsafe (minutes)
35
ELECTRIC OR GAS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 43°F — open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control
M1X-GE
CI/CO*
11°F / 1°F
Indoor Unit Only, Pressure Defrost
Termination*
48°F
*Use a Temperature Pressure Chart to
determine PSIG conversions.
Estimated Charge (lb)**
M1X-GE
4 ft
0.9
6 ft
1.2
8 ft
1.7
12 ft
2.3
**This is an average for all refrigerant types.
Actual refrigerant charge may vary by
approximately half a pound.
M1X-GE
NSF Certification
This merchandiser model is manufactured to meet ANSI/NSF
(National Sanitation Foundation) Standard #7 requirements for
construction, materials & cleanability.
4 of 5
M1X-GE Technical Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact Excel M1X-GE
Meat, Delicatessen
Precut and Packaged Produce
Electrical Data
4 ft
6 ft
8 ft
12 ft
Number of Fans—4W
1
2
2
3
Amperes
Watts
4 ft
6 ft
8 ft
12 ft
4 ft
6 ft
8 ft
12 ft
Evaporator Fan
120V
60Hz
Standard
0.31
0.62
0.62
0.93
24
48
48
72
120V
50Hz
Standard
0.38
0.76
0.76
1.14
27
54
54
81
230V
60Hz
Export
0.15
0.30
0.30
0.45
24
48
48
72
230V
50Hz
Export
0.18
0.36
0.36
0.54
27
54
54
81
120V
60Hz
Energy Efficient
0.12
0.24
0.24
0.36
8
16
16
24
230V
60Hz
Energy Efficient
0.06
0.12
0.12
0.18
8
16
16
24
Minimum Circuit Ampacity
120V
60Hz
Standard
0.51
0.82
0.82
1.13
120V
50Hz
Standard
0.58
0.96
0.96
1.34
230V
60Hz
Export
0.35
0.50
0.50
0.65
230V
50Hz
Export
0.38
0.56
0.56
0.74
120V
60Hz
Energy Efficient
0.32
0.44
0.44
0.56
230V
60Hz
Energy Efficient
0.26
0.32
0.32
0.38
Maximum Over Current Protection 120V
20
20
20
20
Maximum Over Current Protection 230V
15
15
15
15
5 of 5
P/N 0475009_C
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Impact Excel M1X-GE
Meat, Delicatessen
Pre-cut and Packaged Produce
ESTIMATED SHIPPING WEIGHT 5
Case
Solid End
4 ft
6 ft
8 ft
12 ft
(each)
lb (kg)
400 (181)
500 (227)
700 (318)
900 (408)
50 (23)
5 Actual weights will vary according to optional kits included.
Defrost
Termination
Thermostat
2
To
Condensing
Unit
}
Dark
Blue
Light
Blue
3
Refrigeration
Thermostat
= 120V POWER
= 120V NEUTRAL
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS GRAYED COMPONENTS IN 12 FOOT MODELS ONLY.
120V
NEUTRAL
120V
POWER
Fans
1
BROWN BAND
BROWN BAND
4 ft
6 ft
8 ft
12 ft
Fan Wiring
Offtime Defrost
Product Data
ARI Refrigerated Volume 1 (Cu Ft/Ft)
1.38 ft3 /ft (0.13 m3 /m)
Recommended Usable Cube 2 (Cu Ft/Ft)
1.52 ft3 /ft (0.14 m3 /m)
ARI Total Display Area 3 (Sq Ft/Ft)
2.62 ft2 /ft (0.80 m2 /m)
Shelf Area 4 (Sq Ft/Ft)
2.51 ft2 /ft (0.76 m2 /m)
1 Computed using ARI 1200 standard methodology: Refrigerated Volume, ft3 [m3]/Unit of Length, ft [m]
2 ARI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]
3 Computed using ARI 1200 standard methodology: Total Display Area, ft2 [m2]/Unit of Length, ft [m]
4 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann
Product Reference Guide. The standard shelf complement for this model is NONE.