Personal Audio Analayzer
Analizador Personal de Audio
ENGLISH .........................................I
ESPAÑOL .....................................II
APPENDIX .....................................III
V1.6 07/27/2017
CONTROLS AND DISPLAY..............................................................................................3
GETTING STARTED.................................................................................................5
OPERATING TIPS...................................................................................................5
AUDIO ANALYSIS FUNCTIONS........................................................................6
RTA - Accoustic............................................................................................6
SPL Meter....................................................................................6
RT60..............................................................................................7
RTA - Electrical Signal......................................................................................8
Level Meter..............................................................................................................9
MEMORY...........................................................................................9
Store............................................................................................................9
Recall............................................................................................10
Average...................................................................................10
EQ Setting............................................................................................10
SETTINGS................................................................................................11
Weighting......................................................................................11
Level Range...................................................................................12
Max Level............................................................................................12
Peak Hold...................................................................................................................12
Response Time....................................................................................................12
Calibration.....................................................................................................12
PHASE CHECK.....................................................................................................13
GENERATOR...................................................................................................13
POWER.......................................................................................................13
SIMULTANEOUS OPERATION WITH DESKTOP..................................................15
SPECIFICATIONS.........................................................................................................17
APPENDIX
DIMENSIONS......................................................................................................1
Phonic reserves the right to improve or alter any information within this document without prior notice.
CONTENTS
USER'S MANUAL
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
1. Read these instructions.
2.
Keep these instructions.
3.
Heed all warnings.
4.
Follow all instructions.
5.
Do not use this apparatus near water.
6.
Clean only with dry cloth.
7. Do not block any ventilation openings. Install in
accordance with the manufacture’s instructions.
9.
Do not install near any heat sources such
as radiators, heat registers, stoves, or other
heat.
10.
Do not defeat the safety purpose of the polarized
or grounding plug. A polarized plug has two
blades with one wider than the other. A grounding
plug has two blades and a third grounding prong.
The wide blade or the third prong is provided for
your outlet, consult an electrician for replacement
of the obsolete outlet.
11.
Protect the power cord from being walked on or
pinched particularly at the plugs, convenience
receptacles, and at the point where they exit from
the apparatus.
12.
the manufacturer.
13.
Use only with the cart, stand, tripod,
manufacturer, or sold with the
apparatus. When a cart or rack is
used, use caution when moving the
cart/apparatus combination to avoid
injury from tip-over.
14.
Unplug the apparatus during lightning storms or
when unused for long periods of time.
15.
Servicing is required when the apparatus has
been damaged in any way, such as power supply
cord or plug is damaged, liquid has been spilled
or objects have fallen into the apparatus has been
exposed to rain or moisture, does not operate
normally, or has been dropped.
8.
No naked flame sources, such as lighted candles,
should be placed on the apparatus.
Class 2 Wiring for all other TERMINALS provided
the audio output power exceeds 10 W per channel
under normal operating conditions or the apparatus
is intended to be installed or interconnected in the
field by a SKILLED PERSON.
17.
18.
Use this apparatus in moderate climates.
16.
building-in space such as a book case or similar
unit, and remain a well ventilation conditions at
open site. The ventilation should not be impeded
by covering the ventilation openings with items
such as newspaper, table-cloths, curtains, etc.
19. WARNING: The mains plug/appliance coupler is
used as disconnect device, the disconnect device
shall remain readily operable.
20. This apparatus is for professional use only.
21. WARNING:
shock, do not expose this apparatus to rain or
moisture. The apparatus shall not be exposed to
liquids, such as vases, shall not be placed on
apparatus.
22.
an equilateral triangle is intended to alert
the user to the presence of non-insulated
“dangerous voltage” within the product’s
magnitude to constitute a risk of electric
shock.
Warning: To reduce the risk of electric shock, do
not remove cover (or back) as there are no user-
personnel.
The exclamation point within an equilateral
triangle is intended to alert the user to
the presence of important operating and
maintenance instructions in the literature
accompanying the appliance.
23. Protective
earthing
terminals.
The
apparatus should be connected to a
mains socket outlet with a protective
earthing connection.
ATTENTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN!
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER AS THERE ARE NO
USER-SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED PERSONNEL.
IMPORTANT SAFETY INSTRUCTIONS
Thank you for purchasing the Phonic PAA3 Personal
Audio Assistant, a highly accurate audio analyzer that sits
comfortably in the palm of your hand, and features all the
tools you need to set up any audio system.
With 31-band real-time spectrum analysis, Sound Pres-
sure Level and dBu / dBV / line voltage measurement, EQ
setting, phase checking, and reverb time analyzation, the
PAA3 is the ideal companion for all sound engineers. This
personal audio assistant is battery powered (4 AA size),
with a built in microphone, and XLR inputs and outputs,
ensuring all audio analyzing situations are possible. With
the PAA3, you will conquer the accoustics of all environ-
ments with precision and ease.
Phonic understands the importance of sound reproduction
management. We know that as a professional, your main
concern is sound quality. Consequently, with an audio tool
like the PAA3, you expect a precise ruler to obtain proper
measurements and guarantee the best possible quality of
sound that any professional would expect. Phonic, there-
fore, took the utmost of care in ensuring the PAA3 is an
extremely accurate and effective means for you to gather
all the useful data to determine what your set up needs.
To help you familiarize yourself with the PAA3, this manual
includes instructions on every function listed in the main
menu and sub-menus. It is recommended that you take
the time to have a read of it, before you store it in an easily
accessible place, in case it’s needed in future.
FEATURES
● Palm Sized Audio Analyzer
● 31-band Real Time Spectrum Analyzer
● Built-in calibrated measurement microphone
● Sound Pressure Level Meter from 30 dB to 130 dB
● Line signal measurement displayed in dBu, dBV, or
Voltage
● A, C weighting or flat
● 3 level range selection for dB SPL and line signal
● Line signal measuring range:
dBu = -50 ~ +40dBu
dBV= -52 ~ +38dBV
Volts = 5mV ~ +80V
● Maximum level and peak hold display
● 4 standard response times: 35 ms, 125 ms (F), 250 ms
(M), 1 sec (S)
● 10 memories for measurement, and 6 for average
calculation
● 31-band EQ setting level display (boost/cut)
● 160 x 160 graphic display with backlight and contrast
adjustment
● Phase checker
● SPL meter Calibration through sound level calibrator
(eg: B & K Type 4231)
● Reverb Time (RT60) Analyzer
● Noise generator with pink noise, 1 kHz and polarity test
signal, balanced output
● USB communication port, for simultaneous operation
through laptop or PC
● Low power consumption for up to 7 hours continuous
operation with 4 AA size alkaline batteries (adapter
power supply operation available. When power is used
from adapter, it automatically cuts off battery power)
● 3 power modes: (1) Power saving mode: Auto Off- when
none of the buttons has been pressed for 15 minutes
(2) Manual Off (3) Off
● XLR input and output sockets
INSIDE THE GIFT BOX
1 x PAA3 Unit
4 x AA Size Batteries
1 x AC Power Adaptor
1 x USB Cable
1 x Leather Case
1 x 3/8” and 5/8” Microphone Stand Adaptors
1 x Easy Manual
● 4 x AA Size Batteries
● Power Adaptor
● USB Cable ● Microphone Stand Adaptors
CONTROLS AND DISPLAY
1.
LCD Display
160 x 160 graphic LCD screen provides clear and
large display.
2.
Power / Backlight Button
Before turning the power on, please ensure the
POWER LOCK switch (at the rear of the PAA3) is
set to the “ON” position. Pressing the Power button
for 2 seconds will the power of the PAA3 on. After the
power is on, this button allows users to turn the LCD
backlight on and off. Holding the button for about 3
seconds will initiate the PAA3’s shutdown sequence,
saving all stored memories of the PAA3.
3.
Right / Down Button
Press this button to scroll down or to the right
of the currently selected option.
4.
Left / Up Button
Press this button to scroll up or to the left of the
currently selected option.
5.
Enter Button
Press this button to move from Real Time Spectrum
Analyzer (RTA) display to the PAA3’s function menu.
After moving the cursor to a desired function in the
menu by the right/down or left/up buttons, press the
enter button to select.
6.
Jog Control
Jog control, on the left-hand side of this unit, provides
users with a hassle free method of scrolling menus
and selecting options with a single hand. Simply
rotate to scroll up and down menus and push the
wheel inwards to select (to either enter a sub menu
or finalize a setting). Alternately, the three function
buttons (the afore-mentioned buttons 3 to 5) may also
be used to scroll options and finalize selections.
7.
6V DC Power Input
This port is used to connect the included 6V AC to
DC converter. When adapter is plugged in, the battery
power will be replaced by the adaptor, allowing users
to use the PAA3 without fear of running out of power.
Use the adapter provided along with the PAA3 only,
as to avoid damaging the device. Please note that
this will not charge batteries placed into the PAA3’s
batery compartment.
8.
USB Port
This USB connector is for the addition of the provided
USB cable, to be connect the PAA3 to any desktop
or notebook computer with a USB port. Please see
the Simultaneous Operation With Desktop Computer
section for more information.
1
2
3
4
5
6
7
8
Male XLR Socket (Line Output)
Through this XLR male connector, users can send out
three built-in audio test signals: pink noise,1 kHz tone,
and the polarity signal. The output level is balanced
-10dBu under a 6V DV power supply.
10. Female XLR Socket (Line Input)
This port allows you to send balanced, linelevel input
to the PAA3. This signal input allows you to measure
signals in dBu, dBV or AC voltage for balanced
and unbalanced signals. It is particularly useful for
checking the phase of a connections.
11. Contrast Control
By adjusting this control, users can change the
contrast of the PAA3’s LCD screen to better adapt
the device to different lighting conditions.
12. Power Lock
Set this switch to the “ON” position before turning on
the PAA3. You can set to the “OFF” position to prevent
accidental powering up of the PAA3 when the unit is
not in use. It is recommended that users move this
switch to the off position when the PAA3 will not be
used for a long period of time. Provided that the shut
down procedure was followed correctly, turning this
switch off after saving your settings will not cause the
loss of any data.
13. Built-in Microphone
Turn this accurate built-in Omni-directional mic to
operation position (stands 45 degrees) by pressing
the axis base. Always press the axis base before
rotating the mic, as it is locked into place. If you
attempt to rotate the mic without pushing in first, you
could very well damage your PAA3.
14. Stand Mount
A stand mount is located on the back for connection
to a tripod or any other stand that has a standard #6
- 20 connecting screw, often found on camera tripods.
Also included is a stand adapter, allowing the PAA3
to be mounted on microphone stands as well.
15. Battery Compartment
The PAA3 requires four AA batteries for operation.
Under normal conditions, the PAA3 can last for up to
seven hours of continuous operation with the use of
Duracell alkaline batteries.
Open the battery compartment and insert four AA
batteries, ensuring the positive and negative ends
are correctly aligned. You may simply opt to use the
6V DC power adaptor. To do so, plug the DC-head
of the power adaptor to the PAA3, and the wallwart
power connector into a suitable AC power source.
ATTENTION: Use the adapter provided along with the
PAA3 only, as to avoid damaging the PAA3. When
connecting the adaptor, ensure the power of the PAA3
is off. Sudden unplugging of the adaptor power may
cause the system to crash.
2.
Push the axis base to release the PAA3’s built in
microphone. To best measure audio properties, turn
the microphone until it sits at a suitable angle. The
mic will lock into place at around 45 degrees.
3.
Set the power switch (on the rear of the PAA3) to the
“ON” position.
4.
Press and hold the power button (on the front) for
approximately three seconds to turn the power of the
PAA3 on.
5.
A startup screen will appear for about 10 seconds,
then the real time spectrum analyzer will appear on
the screen. Above the RTA, users will note the level
range, weighting type, maximum sound pressure
level, frequency range and SPL meter.
6.
If a backlight is needed, simply press the power /
backlight button. Press again to turn the backlight
off.
7.
Use the ENTER button to bring up the main PAA3
menu, then the UP / RIGHT and DOWN / LEFT
buttons to navigate through the various options. Press
the ENTER button to enter the main menu and use
the UP / RIGHT and DOWN / LEFT buttons to select
a function. Then press ENTER again to activate the
highlight function or to enter into the submenus.
The user may also use the jog control to activate all
functions.
OPERATING TIPS:
1.
All functions can be activated by using the ENTER,
LEFT / UP and DOWN / RIGHT buttons, or by the jog
control. It is recommended to use these three buttons
when taking low SPL measurements.
2.
Pressing the ENTER button when the ESC (escape)
is highlighted in most of the function menus will allow
you to exit the main menu or sub-menus.
3.
Press and hold the ENTER button or jog control for
2 seconds in most of the function menus to return to
the real time spectrum analyzer.
4.
When in RTA mode, holding the jog control or the
ENTER button for 2 seconds will automatically jump
to the Sound Pressure Level or Signal Level meters.
5.
Always turn off the power by going to the POWER
menu. Select OFF if you wish to save the measurement
data and function setting into the memory of the PAA3.
You may also simply hold the power / backlight button
for 2.5 seconds.
6.
It is not recommended to continue using PAA3 for any
measurement when the battery is low. Always have
extra batteries or the 6VDC power adaptor ready to
ensure the accuracy of measurements.
7.
When any result is above the level range, the
measurement is still accurate unless a CLIPPING
warning appears in the LEVEL box while taking the
measurement. When clipping occurs, reset the level
range.
8.
To refresh the maximum SPL display, press both the
left and right buttons simultaneously.
9.
Turn on backlight only when the level range is set at
70~130 dB SPL or -20~+40 dBu. A noise will occur
when turning on the backlight and it may affect the
result of measurements in the lower range.
10.
While taking measurements, hold the right button and
press enter to immediately jump immediately to the
STORE page.
When the battery is low, a blinking - and very aptly titled -
“BATTERY LOW” icon will appear in the WEIGHT box, and
remain on screen for the last 3 minutes of battery life. Low
quality batteries may cause the PAA3 to shutdown without
warning. An enlarged, blinking battery icon will appear in
the center of the LCD screen if the user starts the PAA3
with insufficient battery power.
Quick Shutdown: Simply press the Power Button down for
around 2.5 seconds and the shutdown procedure will be
initiated automatically. This can save you valuable minutes
while on the job!
AUDIO ANALYSIS FUNCTIONS
The following section contains information concerning
acoustic analysis, and illustrates how to use the PAA3 to
measure various properties of your audio.
RTA (Real Time Analyzer) - Accoustic
This function analyzes the audio received through either the
built-in mic or Line In connection, divided into 31-bands at
1/3 octave intervals, and displays the relevent information
on a bar graph that shows the decible level of each band
of sound from 20 Hz to 20 kHz in four different response
times (35 ms, 125 ms, 250 ms, and 1 sec) and in three
weighting types (A weighting, C weighting and Flat). For
more info on response times and weighting, please consult
the appropriate sections.
Procedure:
1.
After the start up sequence of the PAA3 is complete,
the real time analyzer will appear on the LCD screen.
2.
Go to the SETTING menu to set the appropriate
weighting, level range, response time, or other
relevant properties.
3.
Select VALUE from the main menu to enter RTA
mode.
4.
Press ENTER to freeze measurement data. Press
ENTER again on the highlighted VALUE to view the
value of each center frequency.
5.
Use the LEFT/UP and RIGHT/ DOWN buttons or
simply scroll the JOG control to view the level of dB
SPL in real-time for the center frequency of all 31
bands. The default readout is the ALL FREQUENCY
level.
Beneath you will find two readouts: the numbers in the
left column display the frequency while the numbers
in the right column display the frequency levels. The
graphic shown indicates that the user has set the
level range at 50~110 SPL, A weighting. The max
level during the time of measurement is 105.5 dB,
The user is reading at 1 kHz, which has a dB SPL
of 102.8. If you would like to store the measurement
data in the memory of PAA3, go to the STORE menu.
Users can save the measured spectrum data into
one of the ten memories. Please refer to MEMORY/
STORE for more information.
6.
Scroll through the various values located in the ‘Hz’
box until you come to a flashing ESC. Press enter to
exit RTA mode.
SPL (Sound Pressure Level) Meter
This feature of the PAA3 gives users an accurate
measurement of the overall “loudness” of their sound,
measured in decibels (dB). This is a true RMS-measurement,
using standard display time average, and standard A, C,
and Flat weightings.
Procedure:
1.
Enter the SPL/LINE menu and set the measurement
unit to SPL.
2.
You may select a range level, weighting, response
time or a maximum level by going into the SETTINGS
menu, then onto the appropriate menus. The selected
values of these options will be displayed above the
RTA on the PAA3’s default screen.
RANGE
50 ~ 110 SPL
WEIGHT
MAX
A
99.2
On the main RTA display, hold the ENTER button for
approximately 2 seconds to activate the SPL screen.
Press the ENTER button once to exit.
NB. You can easily refresh the Max SPL value by holding
both the ← left and → right keys simultaneously for at
least one second.
RT60 (Reverb Time Analyzing)
The RT60 function of the PAA3 is easy enough to
understand: it is basically the time it takes for a signal to
drop 60 dB. Getting the average of many different RT60
calculations from around a room allows users to get an idea
as to how much absorption or reflection of audio the room
provides. Depending on your needs, you may wish to have
a high or low RT60 measurement. For example, for public
speaking, an RT60 measurement of less than 1 second
is preferable, as to have a clear, concise voice conveyed
to the audience. With choirs or instrumental music, an
RT60 measurement of greater than 1.5 seconds may be
appropriate. It all depends on your needs.
Measuring Reverb Time:
1.
Press enter to open the main menu and select “RT60.”
2.
Simply click “RUN” to get your RT60 reading.
3.
The PAA3 will wait for a signal greater than 30 dB
over the background noise level (detected prior to the
measurement). A little helpful hint: the louder the test
signal, the greater accuracy of your RT60 calculation.
4.
Play pink noise through your audio system. Slowly
move the master fader up, to a point where the audio
level received by the PAA3 is greater than 30 dB.
Quickly mute the system to get your RT60 reading
as accurate as possible.
5.
After the measurement is taken, the RT60
measurement will appear onscreen.
Accumulation: AC 01
Users are able to accumulate various RT60 calculations
by pressing enter while the “ACxx” (where xx equals the
number of accumulated values) option is highlighted. Up
to 30 measurements can be accumulated. When RT60
measurements are accumulated, the average of said
memories is automatically taken and displayed onscreen.
After 30 memories have been accumulated, users will be
forced to store their data, or else lose it.
Store: STO
Storing the results of RT60 measurements is simple. First
highlight the STO option and push ENTER. When the store
page comes up, choose one of the memory slots from 1 to
10, and select YES to store. The memory slot you selected
will have a box surrounding the number now, as to indicate
that a memory is stored in that particular slot. Selecting
“A/C” will clear all memory slots.
Recall: RCL
RT60 measurements can be recalled at anytime by
selecting the “RCL” option in the RT60 menu. Memory
slots 1 to 10 and A to F can all be recalled with ease. Each
memory location page displays only 4 memories at a time,
however, therefore users must select NEXT to continue
onto the next page of stored memories.
Average: AVG
To get the average of RT60 measurements that are stored
in the PAA3, simply select AVG. Select from memories 1 to
10 (memory slots with saved data are indicated by a box
surrounding the slot number), a dot will appear next to the
number to show that a memory slot is selected. When all
memories are selected, simply select AVG to determine
the average, or ESC to escape. When differently weighted
items are attempted to be averaged, a warning will appear
onscreen advising users to select again.
RTA (Real Time Analyzer) - Electrical Signal
By simply connecting an XLR jack to the PAA3’s in jack, the
RTA function can accurately measure your signal.
Procedure:
1.
Enter the SPL/LINE menu and set the measurement
unit to dBu, dBV, or voltage, as required.
2.
Send a signal through the PAA3’s female XLR jack
(Pin 2 - Hot; Pin 3 - Cold; Pin 1 - Ground).
3.
Go to the SETTING menu, where you may want
to adjust the RANGE, WEIGHTING, RESP TIME
(response time), or MAX LEVEL of your measurement.
4.
Return to the RTA display. Here you can read the level
of any or all frequencies. If all frequency readouts are
needed, press “ENTER” button (or the jog control) for
two seconds to enter line level meter.
Measure the line voltage level in units of dBu, dBV, and
AC voltage, using standard response time, and standard
A, C, or flat weightings (under normal conditions, flat is
preferable). Using the PAA3 to meaure DC voltage may
damage the PAA3 and will void the warranty.
Procedure:
1.
Enter the SPL / LINE menu and set the measurement
unit to dBu, dBV, or voltage, as required.
2.
You may select a range level, weighting, response
time or a maximum level by going into the SETTINGS
menu, then onto the appropriate menus. The selected
values of these options will be displayed above the
RTA on the PAA3’s default screen.
3.
On the main RTA display, hold the ENTER button for
approximately 2 seconds to activate the Level Meter
screen. Press the ENTER button once to exit.
NB. You can easily refresh the Max SPL value by holding
both the ← left and → right keys simultaneously for at
least one second.
ATTENTION:
If the level is lower than 127 mV when measuring voltage,
the PAA3 will show it in mV. If the level is higher than
127mV, the data will be shown in voltage For example,
120mV will read as 120.0mV, and 200mV will be shown
as 0.2V.
The measurements for line voltage cannot be saved into
the memory of the PAA3.
MEMORY
The sub-menus of MEMORY include: STORE, RECALL,
AVERAGE, EQ SETTING. Through these options, users
are able to store their RTA measurements.
Store
The user can save up to 10 sets of measured data (1 to 10),
as well as 6 averaged sets (A to F), into the memory of the
PAA3, allowing them to be used later for further analysis
or uploading to your computer.
Procedure (after making an accoustic
RTA measurement):
1.
To enter the store menu, hold the right button down
and press ENTER, or go into the MEMORY menu
and select STORE.
2.
Select any slot, from position 1 to 10, and press YES
to finalize. Previously saved data will be over-written.
3.
Memory locations with stored data will be indicated
with a box surrounding the slot number.
4.
Selecting A/C in the STORE menu will automatically
clear all memory slots.
ATTENTION: This function is only available when for
accoustic analysis.
������ �
����
� � ���
STORE
�����
�
�� � ��� �
10
�
�
�
A 31
100
315
1K
10K
3.15K
� ����
���
���
���
ESC
3
4
7
8
� YES
NO
9
MEMORY
Users can recall all data saved in the memory of the PAA3
to read the measurements.
Procedure:
1.
Enter into the MEMORY menu and select RECALL.
2.
Select any of the used memory slots (indicated by a
box surrounding the slot number) from 1 to 10 or A
to F.
3.
Each value will be displayed under VALUE in a 31-
band center frequency value and an all frequency
value.
4.
When you see a flashing ESC in the Hz column, press
ENTER to return to the MEMORY menu.
Average
The user can choose from memories 1 to 10 to compute
average calculations, which are essential for EQ setting.
Procedure:
1.
Go to the MEMORY menu and select AVERAGE.
2.
Select any combination of data from memories
1 to 10 by moving the cursor to that number and
pushing the ENTER key, or simply choose ALL if
you want to do the average calculation for all ten
saved measurements. Move the cursor over selected
memories and press ENTER again to unselect.
3.
A small dot will appear to the left of selected memory
slots for identification.
4.
Highlight AVG and press the ENTER key after
all selections have been made. A list of selected
measurements will be shown for confirmation.
5.
Press RUN and the PAA3 will automatically calculate
the average, or press ESC to cancel.
6.
After running the average calculation, COMPLETE
will appear on the screen. The user may then select
from memory slots A to F (pressing YES to confirm)
to save selected average calculations to the PAA3.
Previously saved data will be automatically over-
written. The PAA3 will automatically revert back to
the EQ SETTING menu as soon as calculations are
complete.
ATTENTION:
It is not recommended to calculate average of saved data
with different weighting settings. The PAA3 will ignore the
peak value when calculating the average, even if the peak
value was activated.
EQ Setting
The EQ setting of audio system will vary from one venue
to another. The ultimate goal in setting your EQ is to create
a completely flat response and to eliminate every possible
source of feedback. Though the PAA3’s EQ SETTING
function, even a novice user can successfully accomplish
this.
Procedure:
1.
Play pink noise through your audio system.
2.
Pick a number of significant locations around the
area the audience will be situated, and take RTA
measurements, and save each into the PAA3’s
memory.
3.
Enter into the MEMORY / AVERAGE menu, and select
the saved memories measured from those locations
to calculate the average.
4.
Go to the MEMORY / EQ SETTING menu. You will
discover the amount of dB you need to boost or cut
in each center frequency by using the Jog. Control
or the UP/DOWN buttons to scroll. Example shown
indicates that the user should cut -5.2 dB at 1 kHz.
ATTENTION:
Any user’s EQ setting ability is limited by the temperature
and the size of the audience at the time measurements
were taken.
The sub-menus of SETTING include WEIGHTING, LEVEL
RANGE, MAX LEVEL, PEAK HOLD, RESPONSE TIME,
and CALIBRATION.
Weighting
Any audio analyzer needs to be designed so that it
hears sound properties in the same way as humans.
Generally, the sensitivity of human hearing is restricted to
the frequency range of 20 Hz to 20 kHz. The human ear,
however, is most sensitive to sounds in the range of 500
Hz to 8 kHz. The ear becomes progressively less sensitive
to sound out of this range.
To account for this limitation of human hearing, many
audio analyzers, including the PAA3, incorporate a filtering
of acoustic signals according to frequency. This filtering
(weighting type) is devised to correspond to the varying
sensitivity of the human ear to sound over the audible
frequency range. The PAA3 comes with both A-weighting
and C-weighting standardized by the ANSI (American
National Standards Institute). A-weighting is the most
frequently used weighting type and is used for measuring
lower sound levels, while Cweighting is best suited for
higher sound levels. The user can set the weighting for
measurements in dBu, dBV or voltage.
Procedure:
1.
Go to the SETTING/ WEIGHTING menu.
2.
Select an appropriate weighting for the measurement.
A tick appears next to your selection.
3.
Press ESC to the previous menu.
Level Range
The PAA3 has three different ranges for measurements in
SPL, dBu, dBV and voltage.
Procedure:
1.
Go to the SETTING menu, and proceed onto the
LEVEL RANGE menu.
2.
Select an appropriate level range for your measurement
and press the ENTER button.
3.
Press ESC to return to the previous menu, or hold
the ENTER button for 2 seconds to revert back to the
RTA screen.
WEIGHTING
FLAT
A
C
SETTING
ESC
A 31
100
315
1K
10K
3.15K
LEVEL RANGE
70 ~ 130 dBSPL
30 ~ 90 dBSPL
SETTING
50 ~ 110 dBSPL
ESC
A 31
100
315
1K
10K
3.15K
SPL: 30 ~ 90 /
50 ~ 110 /
7 0 ~ 130
V
dBu: - 50 ~ +10 /
-35 ~ +25 / - 20 ~ +40
dBV: - 52 ~ +8
/ - 37 ~ +23 / - 22 ~ +38
VAC: 5 m ~ 2.45V / 14m ~ 14V
/
77.5m ~ 8 0
Maximum level your audio has reached will constantly be
shown on the LCD screen. The user should reset the max
level before each new measurement.
Procedure:
1.
Enter the SETTING menu, then onto the MAX LEVEL
menu.
2.
Highlight RESET and press ENTER button to reset the
max level measurement (doing so will automatically
return you to the SETTING sub-menu). Press ESC
to return if it you do not want to reset.
3.
A new max level display will be shown in the MAX
column three seconds after returning to the RTA
operation.
Quick Refresh: While on the RTA screen, simply press
the left and right buttons simultaneously to refresh the
maximum level.
Peak Hold
Peak hold allows the user in RTA mode to constantly display
the peak values of all measured frequencies, individually
or collectively.
Procedure:
1.
Enter the SETTING menu, then select the PEAK
HOLD option.
2.
Highlight and select ON to activate peak hold display.
3.
Highlight and select OFF to cancel the peak hold
display function.
4.
Press ESC to return to the SETTING menu.
ATTENTION: When saving the memory with “PEAK HOLD”
on, the peak level will only be displayed when the user
recalls that memory when the PEAK HOLD setting is on.
By setting the PEAK HOLD off, the user may then view the
levels from all frequencies, individually or collectively.
Response Time
Response time settings will vary according to the user’s
measurement goals.
35 ms: Extremely Fast (for explosive sound)
125 ms (F): Fast
250 ms (M): Medium
1 sec (S): Slow
Procedure:
1.
Go to the SETTING menu, then enter the RESP TIME
menu.
2.
Select an appropriate response time (a tick will appear
next to your selection), or ESC to cancel.
Calibration
You should never actually need to calibrate your PAA3. If
measurement data or operation of the unit is abnormal,
however, it may be necessary to. Anyone can calibrate
the PAA3 and regain accurate sound pressure level
measurement by using a sound level calibrator with 1/2”
diameter adapter that sends out a 1 kHz tone. A B&K TYPE
4231 sound level calibrator is suggested.
Procedure:
1.
First, turn the PEAK HOLD OFF and set the RESP
TIME (response time) to 250 ms.
2.
Place a sound level calibrator with a microphone
connector of a 1/2” diameter close to the PAA3’s
built-in mic.
3.
Enter the SETTING menu and activate the function.
4.
Adjust the level measured from the SPL calibrator by
pressing UP/DOWN buttons until the level is equal
to that of the sound level calibrator (typically 94 dB).
Pressing the UP button each time will increase the
value by 0.1dB; pressing the DOWN button each time
will decrease by 0.1 dB.
5.
Press the ENTER button to complete the calibration
and to return to RTA display.
ATTENTION: If you want to cancel calibration, simply press
the ENTER button to exit before making any adjustment.
To resort the default calibration, simply adjust the offset
value to 0.0 dB.
MAX LEVEL
RESET
SETTING
ESC
A 31
100
315
1K
10K
3.15K
RESP TIME
35 ms
125 ms (F)
250 ms
250 ms (M)
c (S)
1 se
SETTING
ESC
A 31
100
315
1K
10K
3.15K
Measuring the phase of a signal allows you to figure out
whether a speaker is correctly wired. A polarity signal is
usually needed when checking the phase of a speaker or
ensure that an output connection is correct.
Procedure:
1.
Go to the SPL/LINE and select dBu to check a
device’s output connection or SPL to check a
speaker’s wiring.
2.
Go to the SETTING menu, and select POLARITY.
3.
If checking speaker wiring, stand one meter in front
of the speaker that plays the polarity
signal, go to the PHASE CHECK
menu and activate.
4.
A large “+” appearing on screen means
the signal is in phase, and the wiring
is correct.
5.
If instead of a “+” you get a “-”, the
speaker is out of phase and should
be corrected.
6.
A big “?” or a screen switching
between plus and minus symbols
means the sound pressure level is at
a level that is not detectable by the
PAA3. So turn it up!
ATTENTION: Make sure the sound pressure level of
the polarity signal from the system is louder than the
environment noise, otherwise the PAA3 will not be able to
detect the phase of the speaker.
GENERATOR
The PAA3 can send out pink noise, a polarity signal, and
a 1 kHz tone, all of which is sent out via the Male XLR
connector (on the bottom of the PAA3) to any external
system, at a level of -10 dBu.
Tones:
Pink noise: mostly used for acoustic environment
adjusting. For example: sound system equalization.
Polarity: often used to check the phase of
speakers.
1 kHz tone: a widely used among the professionals
for audio signal testing.
Procedure:
1.
Connect the PAA3 to your audio system via the XLR-
male connector on the bottom of the device.
2.
Go into the GENERATOR menu and select one of
the signal to activate.
3.
Select ESC to return to previous menu or press OFF
to cancel.
POLARITY
PINK NOISE
1K Hz
ESC
OFF
GENERATOR
A 31
100
315
1K
10K
3.15K
To follow the correct power-down procedure is quite
important to the PAA3. The easiest way to do so, however,
is to hold the POWER / BACKLIGHT button of the PAA3
for approximately 2.5 seconds.
The device will automatically shutdown. If that’s too easy,
and you prefer to do things the difficult way, you may also
do one of the following:
Procedure:
1.
Enter the POWER menu.
2.
Select AUTO OFF, and the PAA3 will automatically
shut itself down after being left idle for 15 minutes.
3.
Selecting MANUAL OFF will disable AUTO OFF
mode, and ensure the PAA3 will not shut itself down
automatically, unless the batteries are low.
4.
Select OFF, and the PAA3 will immediately shut down,
saving all of your settings and measurement data
before hand.
POWER
ESC
AUTO OFF
OFF
MANUAL OFF
A 31
100
315
1K
10K
3.15K
There are many advantages to being able to connect the
PAA3 with your desktop computer or notebook. It allows
remote operation of the PAA3, for one, which is particularly
useful when taking measurements in areas that require an
absense of any individuals. It also allows users to to save
and print data stored in the PAA3’s memory.
The PAA3 software can be found on the website. With this
program, most functions are easily accessible through a
menu identical to that of the PAA3 device itself.
ATTENTION: When operating the PAA3 through a PC, it
is recommended that you make use of the power adapter
instead of batteries. Also, choose an optimal position for
the PAA3 to be placed before controlling the PAA3 with
your computer.
Installing the PAA3 software:
1.
Navigate to the PAA3 page on www.phonic.com and
download the software at the bottom of the page.
2.
Find paa3_setup.exe in the archive and double click
to begin installation.
3.
Select an appropriate installation directory and click
“next” to continue. The PAA3 software will be installed
automatically.
PAA3 ON LINE
Connection:
1.
After installation, open the PAA3 software.
2.
Connect the PAA3 to your PC via the provided USB
cable, then turn the PAA3 on.
3.
Go to FILE, select ON LINE to connect to the
PAA3. The data previously saved in the PAA3 will
immediately be uploaded.
4.
As soon as uploading is finished, you may begin to
operate PAA3 by moving the cursor of the mouse
and click the onscreen MENU to enter the various
functions of the PAA3.
5.
Now that PAA3 is operating simultaneously with the
PC. The functions being activated will show both on
the PAA3 and the PC or laptop.
6.
Go to FILE and click ON LINE once more if you need
to disable the PAA3’s online operation.
Using the PAA3 on line:
The simple menu located below the FILE pull down
menu at the top left hand side of main PAA3 program will
allow users to access the PAA3’s functions. This menu
is basically identical to that of the PAA3 itself, so as long
as you can navigate the PAA3 menu, you will be able to
navigate this one.
Display Type:
Clicking on the SPL METER (or LEVEL METER) button
to the right of the aforementioned menu will allow users
to switch the on screen display type between that of the
spectrum analysis and the meter display.
Memories:
Taking up most of the bottom half of the PAA3 program
window is the memory section. Here lists all stored
memories of the PAA3, downloaded to the computer. The
two tabs allow users to view either the RTA memories or
RT60 memories stored.
Backlight:
The backlight button to the right-hand-side of the PAA3
program will allow users to remotely active the PAA3’s
backlight.
SIMULTANEOUS OPERATION WITH DESKTOP
PAA3 OFF LINE
The following functions can actually be accessed while
in either on line or off line modes, unless indicated
otherwise.
Printing:
1.
Go to FILE, select Print, and a printer selection
window will appear.
2.
Select a printer from the list.
3.
Select all data or one of the 16 memories. Users may
also choose to print RT60 data.
4.
Choose the print quality level (draft, low quality,
medium quality, or high quality).
5.
Click on Print, and the printer window will disappear
as soon as the transmission is complete
ATTENTION: Along with the 31-band value of the selected
memory and the EQ SETTING value, the name of the
file, date of printing, LEVEL RANGE, WEIGHTING, and
maximum level will also be printed on the data sheet.
Open File:
1.
When off line, go to the FILE menu and select “Open
File”.
2.
Locate the file previously saved in your PC and double
click it.
3.
The data is now ready for viewing, editing and any
additions you may want to make to it.
Save File:
1.
Go to the FILE menu and select Save File.
2.
Select a directory (or create a new one), and give a
name to the file.
3.
Click on SAVE to save the file, and your entire session
will be saved under that one file name.
Peak Hold:
1.
Click on ON to view the peak value of each frequency
and all frequency. The level can be found either from
the bar meter or in the RTA peak chart on the right
hand side of the program window.
2.
Click on OFF to view the RTA value of each frequency
and all frequency.
MEMORY
Select one of the memory slots (1 to 10 or A to F) in the
RTA section of the memory chart at the bottom of the
PAA3 software window to view the properties of saved
data. Users can click on the bar-meter in the spectrum to
see a specific frequency for readout or view them in the
RTA Value column.
ATTENTION: User may rename every memory by double
clicking the number of the memory in the memory chart.
Memory Functions:
The Memory pull down menu (as well as the following
options) is not available while the PAA3 is under On Line
operation.
Average:
1.
Go to MEMORY / AVERAGE pull down menu, then
select RTA AVERAGE or RT60 AVERAGE, to activate
average function.
2.
Choose by clicking memory 1 to 10 for average
calculation. The original level range setting of each
memory level range will display next to its number.
3.
Click on AVG to run the calculation, the results of
which will be displayed immediately.
4.
Select a memory from A~F, and click on Save to save
the result (the old one will be over-written), or click
on Cancel to exit. User can view the result (either in
graphic or in text) immediately both in result box or in
the memory chart, with level range displayed at the
top.
EQ Setting:
1.
Select a memory (1 to 10 or A to F) with which you
would like to adjust the EQ.
2.
Go to MEMORY / EQ SETTING and activate EQ
setting function.
3.
Move the cursor and click on each bar meter to find
out how much dB you need to cut or boost for each
center frequency.
Clear:
1.
Go to MEMORY, then onto CLEAR.
2.
Select a memory slot, 1 to 10 or A to F, from the sub-
menu, and the memory will be deleted immediately;
select “All” if you need to wipe all memories saved.
Built-in miniature omni direction condenser microphone
Line
XLR jacks for line input and output
Data Port
USB 1.1 interface
Display
160X160 LCD screen with contrast adjustment and back light
SPL, dBu, dBV, Voltage
Bar graph and digit display
RTA
31-band, 0.5dB resolution Center frequencies ISO standard from 20Hz to 20KHz
Measurement Range
SPL (Microphone input)
30 to 130 dB SPL
dBu (Line input)
-50 to +40 dBu
dBV (Line Input)
-52 to +38 dBV
Voltage (Line Input)
5 mV to 80 V
Setting
Weighting
A, C or Flat
Peak Hold
ON/OFF
Maximum Level Display
RESET
Response Time
35 ms, 125 ms, 250 ms, 1 sec
Other Function
RT60
Reverberation time display, up to 30 seconds
Memory
10 RTA+ 6 average calculation
Average Calculation
For 10 RTA memories
EQ Setting Value Display
31-band
Phase Checker
Through polarity signal
Transmission
Simultaneous operation with PC or laptop through USB port
Noise Generator (Based on 6VDC power source)
Pink Noise
Balanced output, -10 dBu
1K Hz Signal
Balanced output, -10 dBu
Polarity Signal
Balanced output, -10 dBu
Power Source
4 x AA batteries (battery life: up to 7 hours with alkaline batteries)
or external 6 VDC adapter
Dimensions (HxWxD)
144.95 x 82.95 x 39.42 mm (5.7”x 3.26”x 1.55”)
Weight (with batteries)
354 g (0.78 lbs)
SERVICE AND REPAIR
For replacement parts, service and repairs please contact the Phonic distributor in your
country. Phonic does not release service manuals to consumers, and advice users to not
attempt any self repairs, as doing so voids all warranties. You can locate a dealer near you at
http://www.phonic.com/where-to-buy/.
WARRANTY INFORMATION
Phonic stands behind every product we make with a no-hassles warranty. Warranty coverage
may be extended, depending on your region. Phonic Corporation warrants this product for a
minimum of one year from the original date of purchase against defects in material and
workmanship under use as instructed by the user’s manual. Phonic, at its option, shall repair
or replace the defective unit covered by this warranty. Please retain the dated sales receipt as
evidence of the date of purchase. You will need it for any warranty service. No returns or repairs
will be accepted without a proper RMA number (return merchandise authorization). In order to
keep this warranty in effect, the product must have been handled and used as prescribed in the
instructions accompanying this warranty. Any tampering of the product or attempts of self repair
voids all warranty. This warranty does not cover any damage due to accident, misuse, abuse,
or negligence. This warranty is valid only if the product was purchased new from an authorized
Phonic
dealer/distributor.
For
complete
warranty
policy
information,
please
visit
http://www.phonic.com/warranty/.
CUSTOMER SERVICE AND TECHNICAL SUPPORT
We encourage you to visit our online help at http://support.phonic.com/. There you can find
answers to frequently asked questions, tech tips, driver downloads, returns instruction and other
helpful information. We make every effort to answer your questions as soon as possible.
[email protected]
http://www.phonic.com
CONTROLES Y DISPLAY..............................................................................3
INICIANDO..................................................................................5
CONSEJOS DE OPERACION.....................................................................6
FUNCIONES DE ANALISIS DE AUDIO.........................................................7
RTA-Acústica....................................................................................7
Medidor de SPL..................................................................................7
RT60.........................................................................................8
RTA-Señal Eléctrica...............................................................................9
Medidor de Nivel....................................................................................10
MEMORIA..................................................................................10
Almacenamiento...................................................................................10
Llamado..................................................................................11
Promedio......................................................................................11
Ajustes de EQ..................................................................................11
CONFIGURACIONES..................................................................................12
Ponderación..................................................................................12
Rango de Nivel..................................................................................12
Nivel Máximo..................................................................................13
Peak Hold..................................................................................13
Tiempo de Respuesta............................................................................13
Calibración..................................................................................13
ANALIZADOR DE FASE...............................................................................14
GENERADOR..................................................................................14
ENERGÍA....................................................................................15
OPERAION SIMULTANEA CON COMPUTADOR...................................16
ESPECIFICACIONES.................................................................................. 18
APÉNDICE
DIMENSIONES.........................................................................................1
CONTENIDO
MANUAL DEL USUARIO
Phonic se reserva el derecho de mejorar o alterar cualquier información provista dentro de este documento sin previo aviso.
Gracias por comprar el PAA3 Analizador Personal de Au-
dio, un analizador de audio altamente preciso que se ajusta
muy cómodamente el la palma de tu mano, y tiene todas
las herramientas que necesitas para configurar cualquier
sistema de audio.
Con analizador de espectro en tiempo real de 31 bandas,
Medidor de Presión Sonora y medición voltaje de linea de
dBu / dBV, ajuste de EQ, analizador de Fase y analizador
de Tiempo de Reverberación, el PAA3 es el acompañante
ideal para todos los ingenieros de sonido. Este asistente
personal de audio se alimenta de baterias (4AA), con un
micrófono integrado y, entradas y salidas XLR, listo para
cualquier situación de análisis de audio posible. Con el
PAA3, tú conquistaras la acústica de todos los ambientes
con precisión y facilidad.
Phonic entiende la importancia del manejo de la repro-
ducción de sonido. Sabemos que como profesional, tu
preocupación principal es la calidad del sonido. Conse-
cuentemente, con una herramienta de audio como el PAA3,
esperarias una regla precisa para obtener mediciones
apropiadas y garantizar la mejor calidad posible de sonido
que cualquier ingeniero profesional pudiera esperar. Por lo
tanto, Phonic tomó el mayor de los cuidados asegurando
que el PAA3 sea un medio extremadamente preciso y
efectivo para ti de obtener toda la valiosa información para
determinar lo que necesita tu configuración.
Para ayudarte a familiarizarte con el PAA3, este manual
incluye instrucciones de cada función mencionada en el
menú principal y en los submenús. Es recomendable que
tomes tu tiempo para leer sobre estas funciones, antes de
que lo almacenes en un lugar de fácil acceso, en caso de
que lo necesites en el futuro.
CARACTERISTICAS
● Analizador de Audio del tamaño de la palma de la
mano
● Analizador de Espectro en Tiempo Real de 31 ban-
das
● Micrófono de Medición calibrado integrado
● Medidor de Nivel de Presión Sonora de 30 dB a 130
dB
● Display de medición de señal de linea en dBu, dBv, o
Voltaje
● Escalas A, C o flat (weighting)
● 3 rangos de nivel de selección para dB SPL y señal de
linea
● Rango de medición de señal de linea:
dBu = -50 ~ +40dBu
dBV= -52 ~ +38dBV
Volts = 5mV ~ +80V
● Display de nivel máximo y de peak hold
● 4 tiempos de respuesta estándard: 35ms, 125 ms(F),
250 ms (M), 1 seg (S)
● 10 memorias para mediciones, y 6 para calculo prome-
dio
● Display de EQ con ajuste de 31-bandas (boost/cut)
● Pantalla de 160 x 160 con luz de fondo y ajuste de
contraste
● Analizador de fase
● Calibración de medidor de SPL a través de calibrador
de nivel de señal (ej: B&K Tipo 4231)
● Analizador de Tiempo de Reververacion (RT60)
● Generador de Ruido con Ruido rosa, 1 kHz y señal de
prueba de polaridad, salida balanceada
● Puerto de comunicación USB, para operación simulta-
nea a través de una laptop o PC
● Bajo consumo de potencia para hasta 7 horas de ope-
ración continua con 4 baterias AA alcalinas (disponible
operación mediante adaptador de energia. Cuando se
utiliza el voltaje del adaptador, las baterias se cortan
automáticamente)
● 3 modalidades de energia: (1) Ahorro de energia:
Apagado Automático cuando ninguno de los botones
es oprimido por 15 minutos (2) Apagado Manual (3)
Apagado
● Sockets de entrada y salida XLR
DENTRO DE LA CAJA
1 x unidad PAA3
4 x Baterias AA
1 x Adaptador AC de voltaje
1 x USB Cable
1 x Estuche de Piel
1 x 3/8” y 5/8” adaptadores para pedestal de micrófono
1 x Manual En Breve
● 4 x Baterias AA
● Adaptador de Voltaje
● Cable USB ● Adaptadores para pedestal de micrófono
CONTROLES Y DISPLAY
1.
Display LCD
Pantalla LCD de 160 x 160 que provee lecturas claras
y precisas.
2.
Encendido / Luz de Fondo
Antes de encender la unidad, por favor asegúrese de
que el interruptor POWER LOCK (en la parte trasera
del PAA3), este en la posición “ON”. Al presionar
el botón de encendido por 2 segundos, la unidad
se activara. Después de que se encienda, este
botón permite a los uauarios encender y apagar la
luz de fondo del LCD. Oprimir el botón por más de
3 segundos iniciara la secuencia de apagado del
PAA3, guardando todas las memorias almacenadas
de PAA3.
3.
Botón Abajo / Derecha
Presiona este botón para moverte hacia abajo o a la
derecha de la opción seleccionada actualmente.
4.
Botón Arriba / lzquierda
Presiona este botón para moverte hacia arriba o a la
izquierda en la opción seleccionada.
5.
Botón “Enter”
Presiona este botón para cambiarte de la función
de Analizador en Tiempo Real (RTA) al Menú de
Funciones del PAA3. Después de mover el cursor
a la posición deseada en el menú con los botones
derecha/ abajo o izquierda/arriba, presione el botón
de “Enter” para seleccionar.
6.
Perilla de Control (Jog)
Perilla de Control, en el lado izquierdo de esta unidad,
provee a los usuarios de un método sin complicaciones
de navegar en los menús y seleccionar las opciones
con una sola mano. Simplemente gire para navegar
arriba o abajo de los menús y presionar la perilla
para seleccionar (ya sea para entrar a un submenú
o para finalizar un ajuste). Alternativamente, los tres
botones de función (los mencionados botones 3 a 5)
también pueden ser utilizados para navegar entre las
opciones y finalizar las selecciones.
7.
Entrada de Alimentación de 6V DC
Este puerto es utilizado para conectar el convertidor
AC a DC de 6V. Cuando el adaptador está conectado,
las energía son reemplazadas por el adaptador
permitiendo a los usuarios utilizar el PAA3 sin miedo
a quedarse sin baterias. Solo utilice el adaptador
incluido con el PAA3, para evitar dañar el equipo. Por
favor note que esto no cargara las baterias colocadas
dentro del compartimiento de baterias de la unidad.
8.
Puerto USB
Este conector USB es para conectar el cable USB
incluido para conectarse el PAA3 a una computadora
con puerto USB. Por favor vea la sección de
Operación Simultanea con la Computadora para
más información.
1
2
3
4
5
6
7
8
Socket Macho XLR (Salida de Línea)
A través de este conector XLR macho, los usuarios
pueden enviar tres señales de prueba integradas:
ruido rosa, tono de 1kHz y señal de prueba de
polaridad. El nivel de salida es de -10dBu balanceadas
bajo alimentación de 6V DC.
10. Socket Hembra XLR (Entrada de Línea)
Este puerto te pemite enviar entrada de nivel de
línea balanceada al PAA3. Esta entrada de señal te
permite medir señales en dBu, dBV o voltaje de AC
para señales balanceadas y desbalanceadas. Es
particularmente práctico para chequear la fase de
las conexiones.
11. Control de Contraste
Al ajustar este control, los usuarios pueden cambiar el
contraste de la pantalla LCD del PAA3, para adaptar
mejor el aparato a las differentes condiciones de
iluminación.
12. Seguro del Encendido
Ponga este selector en la posición “ON” antes de
encender el PAA3. Puedes cambiarlo a la posición
“OFF” para prevenir encender accidentalente
el equipo cuando la unidad no está en uso. Se
recomienda que los usuarios muevan este interruptor
a la posición de apagado cuando el PAA3 no se
utilice por periodos largos de tiempo. Siempre que el
procedimiento de apagado fue correcto, cambiar este
selector a la posición “OFF” después de guardar tu
configuración, no causara perdida de datos.
13. Micrófono Integrado
Gire este micrófono de precisión integrado
Omni-direccional a la posición de operación
(aproximadamente 45 grados) oprimiendo la base
de eje. Siempre presione la base antes de girar
el micrófono, debido a que está asegurado en su
posición. Si tú intentas girar el micrófono sin oprimir
su base, podrias dañar muy seriamente tu PAA3.
14. Montaje en Pedestal
Se localiza un montaje de pedestal en la parte
posterior para la conexión a un trípode o a cualquier
otro soporte que tenga tornillo de conexión estándar
#6-20, a menudo encontrado en bases para cámaras.
También se incluye un adaptador, permitiendo que
el PAA3 sea montado en cualquier pedestal para
micrófono.
15. Compartimiento de las Baterias
PAA3 requiere cuatro baterias AA para su operación.
Bajo condiciones normales, el PAA3 puede por lo
menos durar más de 7 horas de operación continua,
con el uso de baterias alcalinas Duracell.
Abre el compartimiento de las baterias e inserta
cuatro baterías AA, asegúrate de que las puntas
positivas y negativas están correctamente alineadas.
Puedes simplemente optar por el adaptador de 6V
DC. Para esto, conecta la cabeza del adaptador de
DC en el PAA3, y el conector de pared a una fuente
de AC compatible.
ATENCION: Solo utillza el adaptador incluido con
el PAA3, esto para evitar dañar el equipo. Cuando
conectes el adaptador, asegúrate de que el PAA3
este apagado. Desconectar repentinamente la
alimentación de voltaje, provocara que el sistema
se caiga.
2.
Presiona la base de eje del micrófono integrado
del PAA3 para liberarlo. Para medir mejor las
propiedades del audio, gira el micrófono hasta que
se encuentre en un ángulo aceptable. El micrófono
se asegurara en su lugar cuando alcance alrededor
de 45 grados.
3.
Cambie el selector de energia (en la parte trasera del
PAA3) a la posición “ON”.
4.
Presione y sostenga el boton de encendido (al frente)
por aproximadamente 3 segundos para encender el
PAA3.
5.
Aparecerá una pantalla de inicio por aproximadamente
10 segundos, luego, el analizador de espectro en
tiempo real aparecerá en la pantalla. Arriba del RTA,
los usuarios notaran un rango de nivel, tipo de escala
(weighting), nivel máximo de presión sonora, rango
de frecuencia y medidor SPL.
6.
Si se necesitara de una luz de fondo, simplemente
presione el botón de power/backlight. Presione
nuevamente para apagar la luz de fondo.
7.
Uilice el botón de ENTER para traer el menú principal
del PAA3, entonces utilice los botones UP/RIGHT y
DOWN/LEFT para navegar en las diferentes opciones
de menús. Presiona el botón de ENTER para entrar
al menú principal y utiliza los botones UP/RIGTH y
DOWN/LEFT para seleccionar una función. Luego,
presione nuevamente ENTER para activar la función
de iluminación o para entrar en los submenús. El
usuario tambiénpuede utilizar la perilla de control
para activar todas las funciones.
CONSEJOS DE OPREACION:
1.
Todas las funciones pueden ser activadas al utilizar
los botones ENTER, LEFT/UP y DOWN/RIGHT, o por
la perilla de control. Se recomiendo que utilice los tres
botones cuando tome medidas de SPL bajo.
2.
Presionando el botón de ENTER cuando ESC
(escape) este iluminado en la mayoria de los menús
de las funciones, te permitirá salir del menú principal
o de los submenús.
3.
Presione y sostenga el botón de ENTER o la perilla de
control por 2 segundos en la mayoría de los menues
de función para regresar al analizador de espectro
en tiempo real.
4.
Cuando esta en la modalidad RTA, oprima el botón
ENTER o la perilla de control por 2 segundos saltará
automáticamente a los medidores de Nivel de Presión
Sonora o Nivel de Señal.
5.
Siempre apague la unidad mediante el menú POWER.
Seleccione OFF si desea guardar la información
de medición y la configuración de funciones en la
menoria del PAA3. También puedes simplemente
mantener oprimido el botón power/backligth por 2.5
segundos.
6.
No se recomienda que se continuara utilizando el
PAA3 para cualquier clase de medición cuando
las baterias estén bajas. Siempre tenga baterias
adicionales o el adaptador de voltaje de 6V, para
asegurar la precisión de las mediciones.
7.
Cuando cualquier resultado este por encima del rango
de nivel, la medición es aun precisa a menos que una
advertencia de recorte (CLIPPING) aparezca en el
cuadro de nivel mientras se hacen las mediciones.
Cuando se da el recorte, reinicie el rango de nivel.
8.
Para reiniciar el display de máximo SPL, presione
ambos botones izquierdo y derecho (left/right) al
mismo tiempo.
9.
Encienda la luz de fondo solo cuando el rango de nivel
este de 70~130dB SPL o a -20~+40dBu. Se producirá
un ruido cuando se encienda la luz de fondo, esto
pudiera afectar el resultado de las mediciones en el
rango inferior.
10.
Mientras se toman mediciones, sostenga el
botón derecho (right) y presione ENTER para
saltar inmediatamente a la pagina de almacenar
(STORE).
Cuando la bateria esta baja, un icono que parpadea- y
muy abrupto- de “BATTERY LOW” aparecerá en el
display de WEIGHT, y permanecerá en la pantalla por al
menos 3 minutos de duración de bateria. Las baterias de
baja calidad pueden causar que el PAA3 se apague sin
advertencia. Un icono de bateria alargado, aparecerá en
el centro de la pantalla LCD si los usuarios encienden el
PAA3 con insuficiente energia de baterias.
Apagado Rápido: Simplemente presione el botón de
encendido (Power) por alrededor de 2.5 segundos, y el
procedimiento de apagado será inicado automáticamente.
Esto puede ahorrarte valiosos minutos en el trabajo.
FUNCIONES DE ANALISIS DE AUDIO
La siguiente sección contiene información concerniente al
análisis de la acústica e, ilustra como utilizar el PAA3 para
medir varias propiedades del audio.
RTA (Analizador en Tiempo Real) - Acústica
Esta función analiza el audio recibido a través del micrófono
integrado o de la conexión de linea, dividido en 31 bandas
a intervalos de 1/3 de octava, y despliega la información
relevante en graficas de barras que muestran el nivel de
decibeles para cada banda de sonido, de los 20 Hz a los
20 kHz en cuatro diferentes tiempos de respuesta (35 ms,
125 ms, 250 ms y 1 seg.) y en tres tipos de ponderación (A
weighting, C weighting y Flat ). Para más información sobre
tiempos de respuestas y ponderación (weighting), por favor
consulte las secciones apropiadas.
Procedimiento:
1.
Después de que la secuencia de arranque del PAA3
esta completa, el analizador en tiempo real aparecerá
en la pantalla LCD.
2.
Ve al menú de ajustes (SETTING) para configurar
las escalas apropiadas, rango de nivel, tiempos de
respuesta y otras propiedades relevantes.
3.
Seleccione VALUE del menú principal para entrar a
la modalidad de RTA.
4.
Presione ENTER para congelar los datos de
medición. Presione ENTER nuevamente en el valor
seleccionado, para ver el valor de cada frecuencia
central.
5.
Utilice los botones LEFT/UP y RIGHT/DOWN o
simplemente navegue con la perilla (jog) de control,
para ver el nivel de dB SPL en tiempo real para la
frecuencia central de las 31 bandas. La lectura de
default es el nivel de TODAS LAS FRECUENCIAS.
Debajo encontraras dos lecturas, los números en la
columna izquierda muestran la frecuencia, mientras
que los números de la derecha muestran los niveles
de las frecuencias. El gráfico mostrado indica que el
usuario ha configurado el rango de nivel a 50~110
SPL, A weighting. El nivel máximo durante el tiempo
de medición es de 105.5 dB. El usuario esta leyendo
a 1kHz, lo cual tiene 102.8 dB SPL. Si tú quisieras
almacenar los datos de las mediciones en la memoria
de PAA3, ve al menú STORE. Los usuarios pueden
guardar la información de espectro medido en una
de las diez memorias. Por favor refiérase a la parte
de MEMORY/SOTRE para más información.
6.
Navegue a través de los varios valores localizados
en la opción “Hz”, hasta que obtenga un mensaje de
“ESC” parpadeante. Presiona enter para salir de la
modalidad RTA.
Medidor de SPL (Sound Pressure Level)
Esta opción en el PAA3 da a los usuarios una medición
precisa de la sonoridad (loudness) de su sonido, medido
en decibeles (dB). Esto es un verdadero medidor RMS,
utilizando tiempo de muestra estándar promedio y,
ponderaciones (weightings) A, C y Flat.
Procedimiento:
1.
Entra al menú SPL/LINE y configura la unidad de
medición de SPL.
2.
Puedes seleccionar el rango de nivel, ponderación,
tiempo de respuesta o nivel máximo yendo a menú de
SETTINGS y, luego a menus apropiados. Los valores
seleccionados de estas opciones serán mostrados
por encima del RTA en la pantalla de default del
PAA3.
RANGE
50 ~ 110 SPL
WEIGHT
MAX
A
99.2
En la pantalla principal RTA, presione el botón ENTER
por aproximadamente 2 segundos para activar la
pantalla SPL. Presione el botón de ENTER una vez
para salir.
NB:Puedes muy fácilmente reiniciar el valor Máximo
SPL al oprimir ambas teclas ←izquierda y derecha→
simultáneamente al menos un segundo.
RT60 (Analizador de Tiempo de Reverberación)
La función RT60 del PAA3 es muy fácil de entender:
básicamente es el tiempo que toma una señal en caer
60dB. Obteniendo el promedio de muchos cálculos
diferentes de RT60 alrededor de un cuarto, permite a los
usuarios darse una idea de cuánta absorción o reflexión de
audio provee el cuarto. Dependiendo de tus necesidades,
tú podrías desear tener una medición alta o baja de RT60.
Por ejemplo, para hablar en público, es preferible una
medida RT60 menor a 1 segundo, para tener una voz
clara y precisa para la audiencia, Con coros o música
instrumental, pudiera ser mas apropiado una medida mayor
a los 1.5 segundos. Depende de tus necesidades.
Midiendo el Tiempo de Reverberación :
1.
Presione ENTER para abrir el menú principal y
seleccionar “RT60”.
2.
Simplemente haga click “RUN” y tendras la lectura
RT60.
3.
El PAA3 esperara por una señal más grande a los 30
dB por encima del nivel de ruido de fondo (detectado
antes de la medición). Un pequeño dato útil: entre
mas grande es la señal de prueba, mayor es la
precisión en el calculo RT60.
4.
Reproduce ruido rosa través de tu sistema de audio.
Lentamente mueve el fader principal hacia arriba,
a un punto donde el nivel del audio recibido por el
PAA3 sea mayor a los 30 dB. Rápidamente cancela
el sistema para obtener tu lectura RT60 tan precisa
como sea posible.
5.
Despupés de que es tomada la lectura, la medición
RT60 aparecerá en pantalla.
Acumulación: AC 01
Los usuarios pueden acumular varios calculos RT60, al
presionar ENTER mientras la opción “ACxx” (el valor xx es
igual al numero de valores acumulados) es seleccionada.
Se puede acumular hasta 30 mediciones. Cuando se
acumulen las mediciones RT60, el promedio de dichas
memorias es automáticamente tomado y desplegado en la
pantalla. Después de que se acumulen las 30 memorias,
los usuarios serán forzados a almacenar su información,
o la perderán.
Almacenar: STO
Almacenar los resultados de las mediciones RT60 es
simple. Primero colóquese en la opción STO y presione
ENTER. Cuando la pagina de almacenado aparezca,
seleccione uno de los slots de memoria del 1 al 10 y,
seleccione si (YES) para almacenar. El slot de memoria
que selecciones tendrá ahora un cuadro rodeando el
número, esto para indicar que una memoria ha sido
almacenada en ese slot en particular. Seleccionar “A/C”,
eliminada todos los slots de memoria y se podrán utilizar
nuevamente.
Recall: RCL
Las mediciones RT60 pueden ser utilizadas nuevamente
cualquier momento que se seleccione la opción “RCL” en
el menú RT60. Los slots de memoria del 1 al 10 y A al F
pueden ser utilizados nuevamente con facilidad. Cada
página de localización de memoria muestra solamente
4 memorias a la vez, por lo tanto los usuarios deben
seleccionar la opción NEXT para continuar a la siguiente
pagina de almacenado de memorias.
Promedio (Average): AVG
Para obtener el promedio de las mediciones RT60 que
son almacenadas en el PAA3, simplemente seleccione
“AVG”. Seleccione de las memorias 1 a 10 (slots de
memoria con información guardada, son indicados con
un cuadro que rodea ese slot de memoria), aparecerá
un punto a un lado del numero de slot para mostrar que
ese slot fue seleccionado. Cuando todas las memorias
están seleccionadas, simplemente sleccione AVG para
determinar el promedio, o ESC para cancelar. Cuando se
quiera promediar diferentes ponderaciones, aparecerá un
aviso en la pantalla para avisar a los usuarios que deben
seleccionar nuevamente.
RTA (Real Time Analyzer) – Señal Electrica
Simplemente al conectar un jack XLR al jack de entrada del
PAA3, la function RTA puede medir con mucha precision
tu señal.
Procedimitoro:
1.
Entre al menu SPL/LINE y configure las unidades de
medición a dBu, dBV o voltaje, como sea requerido.
2.
Envíe una señal a través del jack XLR hembra del
PAA3 (Pin 2 positivo, Pin 3 negativo, Pin 1 ground).
3.
Ve al menú de ajuste SETTING, donde quizás quieras
ajustar el RANGO, ponderación(WEIGHTING),
tiempo de respuesta (RESP TIME), o nivel máximo
(MAX LEVEL) en tu medición.
4.
Regresa a la pantalla de RTA. Aquí tú puedes leer
el nivel de cualquiera de las freuencias. Si son
necesarias todas las lecturas de las frecuencias,
presione el botón ENTER (o la perilla de control)
por dos segundos para entrar al medidor de nivel de
línea.
Medidor de Nivel
Mide el nivel de voltaje de línea en unidades de dBu, dBV
y voltaje de AC, utilizando tiempos de respuesta estándar,
y ponderaciones (wighting) estándar A, C o flat (bajo
condiciones normales es preferable Flat). Utilizando el
PAA3 para medir el voltaje de DC, pudiera dañarlo y hacer
que se pierda la garantía.
Procedimiento:
1.
Entre al menu SPL/LINE y configure las unidades de
medición en dBu, dBV o voltaje, como se necesite.
2.
Puedes seleccionar un rango de nivel, ponderación
(weighting), tiempo de respuedta o nivel máximo,
al ir al menú de ajustes (SETTING), y de ahí a los
menus apropiados. Los valores seleccionados de
estas opciones serán desplegados encima del RTA
en pantalla de default del PAA3.
3.
En el display principal RTA, presione el botón de
ENTER por aproximadamente 2 segundos para
activar la pantalla del Medidor de Nivel. Presione el
botón una sola vez para salir.
NB. Puedes muy fácilmente reinicar el valor Máximo SPL
al oprimir ambas teclas ← izquierda y derecha →
simultáneamente al menos un segundo.
ATENCION:
Si cuando se mida voltaje el nivel es mas bajo que los
127mV, el PAA3 lo mostrara en mV. Si el nivel es mayor
que los 127mV, los datos serán mostrados en voltaje. Por
ejemplo, 120 mV se leerá como 120.0 mV, y 200mV se
mostraran com 0.2V .
Las mediciones para voltaje de linea no pueden ser
guardadas dentro de la memoria del PAA3.
MEMORIA
Los submenus de la memoria (MEMORY), incluyen:
STORE, RECALL, AVERAGE, EQ SETTING. A través de
estas opciones, los usuarios son capaces de almacenar
sus mediciones de RTA.
Almacenamiento
El usuario puede almacenar hasta 10 sets de datos de
medición (1 al 10), así como 6 sets de promedios (A al
F), en la memoria del PAA3, permitiéndoles ser utilizados
después para análisis o para cargar esta información ala
computadora.
Procedimiento (despues de hacer una medición RTA):
1.
Para entrar al menu de almacenado (store), presione
el botón derecho y presione ENTER, vaya dentro
del menu de memoria (MEMORY) y selecciona
STORE.
2.
Seleccione cualquier slot, de la posición 1 al 10 y,
presiones si (YES) para finalizar. Los datos grabados
previamente serán sobreescritos.
3.
Las locaciones de memoria con datos almacenados,
estarán indicadas con un cuadro rodeando al número
de slot.
4.
Seleccionando A/C en el menu STORE, limpiara
automáticamente todos los slots.
ATENCION : Esta función solo estará disponible cuando
se haga un análisis acústico.
������ �
����
� � ���
STORE
�����
�
�� � ��� �
10
�
�
�
A 31
100
315
1K
10K
3.15K
� ����
���
���
���
ESC
3
4
7
8
� YES
NO
9
MEMORY
Los usuarios pueden volver a llamar toda la información
guardada dentro de la memoria del PAA3 para leer todas
las mediciones.
Procedimiento:
1.
Entre al menu de memoria (MEMORY) y seleccione
RECALL.
2.
Seleccione cualquiera de los slots de memoria ya
utilizados (rodeados por un cuadro) del 1 al 10 o de
A hasta F.
3.
Cada valor será desplegado por debajo de VALUE en
los valores de las 31 bandas de frecuencia centrales
y todos los valores de frecuencias.
4.
Cuando vea una imagen ESC que parpadee en la
columna Hz, presione ENTER para regresar al menu
de memoria.
Promedio
El usuario puede escoger de las memorias 1 al 10 para
computar calculos promedios, que son esencialmente para
configurar el EQ.
Procedimiento:
1.
Ve al menu de memoria (MEMORY) y seleccione
AVERAGE.
2.
Selecciona cualquier combinación de datos de las
memorias 1 a 10 moviendo el cursor a ese número
y presionar la tecla de ENTER, o simplemente
escogiendo ALL si quieres hacer el calculo promedio
para las diez mediciones almacenadas. Mueve el
cursor sobre las memorias seleccionadas y presione
ENTER nuevamente para deseleccionarlas.
3.
Un pequeño punto aparecerá a la izquierda del slot
seleccionado, para su identificación.
4.
Seleccione AVG y presione la tecla ENTER después
de que se haya hecho todas las selcciones. Una
lista de mediciones seleccionadas aparecerá para
confirmar.
5.
Presione RUN y el PAA3 automáticamente calculara
el promedio, o presione ESC para cancelar la
operación.
6.
Después de ejecutar el calculo promedio, aparecerá
en la pantalla el mensaje COMPLETE. El usuario
puede seleccionar de los slots de memoria A al F
(presionando YES para confirmar) para guardar los
calculos promedios seleccionados en el PAA3. Los
datos previamente guardados seran automáticamente
sobreescritos. El PAA3 se regresara automáticamente
al menu de EQ SETTING, tan pronto que los calculos
estén completos.
ATENCION: No se recomienda hacer cálculos promedios
de datos con diferentes seteos de ponderación. PAA3
ignorara el valor pico cuando se calcule el promedio, aun
si el valor pico es activado.
Ajustes de EQ
La configuración de EQ del sistema de audio variara de un
sistema a otro. La meta final es ajustar el EQ para crear
una respuesta completamente plana y de eliminar cualquier
fuente posible de retroalimentación . A través de la función
de ajuste de EQ (EQ SETTING) del PAA3, aun un Novato
puede lograr exitosamente esto.
Procedimiento:
1.
Reproduce ruido rosa través de tu sistema de audio.
2.
Toma un número de posiciones importantes
alreadedor del area donde este situada la audiencia y,
toma las mediciones RTA, y guarda cada una dentro
de la memoria del PAA3.
Entra al menu MEMORY/AVERAGE y selecciona las
mediciones guardadas en la memoria de aquellos
lugares, para calcular el promedio.
4.
Ve al menu de MEMORY/EQ SETTING. Descubirás la
cantidad de dB que necesite reforzar o cortar en cada
una de las frecuencias centrales utilizando la perilla
de control, o los botones UP/DOWN para navegar.
Un ejemplo indica que el usuario deberá recortar -5.2
dB a 1kHz.
ATENCION: Cualquier disposición de ajuste de EQ del
usuario estrará limitado por la temperatura y el tamaño de
la audiencia al tiempo de hacer las mediciones.
CONFIGURACIONES
Los submenus de configuraciones (SETTING) incluyen,
unidad de medición (WEIGHTING), rango de nivel (LEVEL
RANGE), PEAK HOLD, tiempo de respuesta (RESPONSE
TIME) y calibración (CALIBRATION).
Ponderación (Weighting)
Cualquier analizador de audio necesita ser diseñado de
tal manera que escuche las propiedades del audio de
la misma manera que los humanos. Generalmente, la
sensiblidad de la audición humana está restringida al
rango de frecuencias que van de 20 Hz a 20 kHz. EL oído
humano, sin embargo, es más sensible a los sonidos del
rango de 500Hz a 8kHz. El oído se hace progresivamente
menos sensible al sonido fuera de este rango.
Para tomar en cuenta esta limitación del oído humano,
muchos analizadores de audio, incluyendo el PAA3,
incorporan un filtrado de señales acústicas de acuerdo a la
frecuencia. Este filtrado (tipo weighting) esta formado para
corresponder a la sensiblidad variable del oído humano
para escuchar sobre el rango de frecuencias audibles.
El PAA3 viene en ambas ponderación (weighting) A y C,
estandarizadas por la ANSI (American National Standars
Institute.) La ponderación A es la mas frecuentemente
utilizada y, es utilizada para medir niveles de señales bajos,
mientras que la ponderación C es mejor acomodada para
niveles de sonido mas altos.
El usuario puede configurar la ponderación de medición
(weighting) para mediciones en dBu, dBV o voltaje.
Procedimiento:
1.
Vé al menu de SETTING/WEIGHTING.
2.
Selecciona una ponderación adecuada para las
mediciones. Aparecerá un tick a un lado de tu
selección.
3.
Presione ESC para ir al menu previo.
Rango de Nivel
El PAA3 tiene tres diferentes rangos de nivel para
mediciones en SPL, dBu, dBV o voltaje.
Procedimiento:
1.
Ve al menu de SETTING y, ve al menu de rango de
nivel (LEVEL RANGE).
2.
Selecciona un rango de nivel apropiado para tus
mediciones y presiona el botón de ENTER.
3.
Presione ESC para regresar al menu previo, o
mantenga oprimido el botón de ENTER por 2
segundos para regresar a la pantalla de RTA.
WEIGHTING
FLAT
A
C
SETTING
ESC
A 31
100
315
1K
10K
3.15K
LEVEL RANGE
70 ~ 130 dBSPL
30 ~ 90 dBSPL
SETTING
50 ~ 110 dBSPL
ESC
A 31
100
315
1K
10K
3.15K
SPL: 30 ~ 90 /
50 ~ 110 /
7 0 ~ 130
V
dBu: - 50 ~ +10 /
-35 ~ +25 / - 20 ~ +40
dBV: - 52 ~ +8
/ - 37 ~ +23 / - 22 ~ +38
VAC: 5 m ~ 2.45V / 14m ~ 14V
/
77.5m ~ 8 0
El máximo nivel que alcance tu audio sera constantemente
mostrado en la pantalla LCD. Usuario deberá reiniciar el
nivel máximo antes de cada nueva medición.
Procedimiento:
1.
Entre al menu SETTING, de ahi al menu MAX LEVEL.
2.
Colóquese en RESET y presione el botón ENTER
para reiniciar la medición del nivel máximo (hacerlo
regresara automáticamente a tu submenu de
SETTING). Presione ESC para regresar si no quieres
reiniciarlo.
3.
Se mostrara un nuevo nivel máximo en la columna
MAX, tres segundos después de regresar a la
operación RTA.
Reinicio Rápido: Mientras este en la pantalla
RTA, simplemente presione los botones izquierdo
y derecho simultáneamente para reiniciar el nivel
máximo.
Peak Hold
La función Peak Hold permite a los usuarios en la
modalidad RTA, ver constantemente los valores pico
de todas las frecuencias medidas, individualmente o
colectivamente.
Procedimiento:
1.
Coloquese en el menú SETTING, de ahí a la opción
PEAK HOLD.
2.
Coloquese en la posición ON para activar el display
Peak Hold.
3.
Coloquese en la posición OFF para cancelar el
display Peak Hold.
4.
Presione ESC para regresar al menu SETTING.
ATENCION: Cuando se guarde en la memoria con la
función PEAK HOLD activada, el nivel de pico solo
se mostrará cuando el usuario llame nuevamente esa
memoria, cuando el PEAK HOLD este activado. Al
desactivar esta función, el usuario podrá entonces ver
lo niveles de todas las frecuencias, individualmente o
colectivamente.
Tiempo de Respuesta
La configuración de Tiempo de Respuesta variara de
acuerdo a las metas en las mediciones del usuario.
35 ms: Extremadamente Rápido (para sonido explosivo)
125 ms (F): Rápido
250 ms (M): Medio
1 seg (S): Lento
Procedimiento:
1.
Ve al menú SETTING, de ahí al menú RESP TIME
(tiempo de respuesta).
2.
Seleccione un tiempo de respuesta apropiado
(aparecerá un tick a un lado de la selección), o ESC
para cancelar.
Calibración
De hecho no necesitaras nunca de calibrar tu PAA3. Si
los datos de medición o la operación de la unidad es
anormal, de cualquier manera, tal vez sea necesario
calibrarla. Quien sea puede calibrar el PAA3 y volver a
tener mediciones de nivel de presión sonora preciso, esto
al utilizar un calibrador de sonido con un adaptador de 1/2”
de diametro que envíe un tono de 1 kHz. Se sugiere un
calibrador tipo B&K 4231.
Procedimiento:
1.
Primero, apague la opción PEAK HOLD y configure
el tiempo de respuesta a 250 mseg.
2.
Coloque un calibrador de nivel de sonido con un
conector de micrófono a 1/2” de diámetro cerca del
micrófono integrado del PAA3.
3.
Entre al menú de SETTING y active la función.
4.
Ajuste el nivel medido del calibrador SPL presionando
los botones UP/DOWN hasta que el nivel sea igual
al del calibrador de nivel de sonido (típicamente
94 dB). Presionando el botón UP cada vez tendrá
incremento el valor por 0.1dB; presionando el botón
DOWN tendrá una disminución de 0.1dB.
5.
Presione el botón de ENTER para completer la
calibración y regresar al display RTA.
ATENCION: Si deseas cancelar la calibración, simplemente
presiona el botón ENTER para salir antes de hacer
cualquier ajuste. Para reponer la calibración de default,
simplemente ajuste el valor de offset a 0.0 dB.
MAX LEVEL
RESET
SETTING
ESC
A 31
100
315
1K
3.15K 10K
RESP TIME
35 ms
125 ms (F)
250 ms
250 ms (M)
c (S)
1 se
SETTING
ESC
A 31
100
315
1K
10K
3.15K
ANALIZADOR DE FASE
Analizar la fase de una señal te da idea si el altavoz está
correstamente cableado. Una señal de prueba de polaridad
es necesaria cuando se analiza la fase de un altavoz, o
asegure que la conexión de salida es la correcta.
Procedimiento:
1.
Ve al menú SPL/LINE y selecciona dBu para analizar
el conector de salida de un dispositivo, o SPL para
analizar el cableado del altavoz.
2.
Ve al menú SETTING y selecciona POLARITY.
3.
Si estás revisando el cableado de un altavoz, colócate
un metro en frente del altavoz que está reproduciendo
la señal de polaridad, ve al menú de PHASE CHECK
y actívalo.
4.
Un signo “+” grande aparecerá en la
pantalla, esto significa que la señal
está en fase y el cableado está
correcto.
5.
Si en lugar de lo anterior, obtienes un
signo “-“, el altavoz está fuera de fase
y debera ser corregido.
6.
Si aparece un gran interrogación “?”
o si se cambia de pantalla entre los
signos más y menos, quiere decir
que el nivel de presión sonora no
es detectado por el PAA3. Así que,
súbele!
ATENCION: Asegúrate de que la presión de sonido de la
señal de prueba de polaridad del sistema sea más fuerte
que el ruido ambiental, de otra manera el PAA3 no sera
capaz de detectar la fase del altavoz.
GENERADOR
El PAA3 puede enviar ruido rosa, una señal de polaridad y
tono de 1kHz, todo esto es enviado vía el conector macho
XLR (en el inferior del PAA3) a un sistema externo, a un
nivel de -10dBu.
Tonos:
Ruido Rosa: Generalmente utilizado para ajustar
ambientes acústicos. Por ejemplo: ecualización de
sistemas de sonido.
Polaridad: utilizada a menudo para verificar la fase
de altavoces.
Tono de 1 kHz: utilizado ampliamente por profesionales
para señales de prueba de audio.
Procedimiento:
1.
Conecte el PAA3 a tu sistema de audio vía el conector
macho XLR, en el fondo del equipo.
2.
Ve dentro del menú GENERATOR (generador) y
selecciona una de las señales para activarla.
3.
Seleccione ESC para regresar al menú previo o
presione OFF para cancelar.
POLARITY
PINK NOISE
1K Hz
ESC
OFF
GENERATOR
A 31
100
315
1K
10K
3.15K
Seguir el procedimiento correcto de apagado es muy
importante para el PAA3. La manera más sencilla de
hacerlo, es, presionando el botón de POWER/BACKLIGHT
del PAA3 por aproximadamente 2.5 segundos. El
dispositivo se apagará automáticamente. Si eso es
demasiado fácil, y prefieres hacer las cosas de la manera
difícil, puedes hacer también lo siguiente:
Procedimiento:
1.
Entra al menú POWER.
2.
Selecciona AUTO OFF y el PAA3 se apagará
automáticamente después de estar inactivo por 15
minutos.
3.
Seleccionar MANUAL OFF deshabilitará la modalidad
AUTO OFF y asegurará que el PAA3 no se apagará
automáticamente a no ser que las baterías estén
bajas.
4.
Selecciona OFF y el PAA3 se apagará inmediatamente,
guardando todas las configuraciones que hiciste de
antemano.
POWER
ESC
AUTO OFF
OFF
MANUAL OFF
A 31
100
315
1K
10K
3.15K
Existen muchas ventajas al poder conectar al PAA3 con
tu computadora. Te permite operar remotamente el PAA3,
que es particularmente útil cuando se toman mediciones
en áreas que requieren la ausencia de cualquier individuo.
También permite a los usuarios guardar e imprimir los datos
almacenados en la memoria del PAA3.
El software del PAA3 se puede encontrar en el sitio web
de Phonic. Con este programa, tendrá la posibilidad de
enlazar su ordenador con su dispositivo PAA3, de esa
forma podrá utilizar la mayoría de las funciones de su
dispositivo PAA3 a través de una interfaz idéntica, pero
utilizando de su ordenador.
ATENCION: Cuando opere el PAA3 a través de una PC,
se recomienda que uses el adaptador de energía en lugar
de las baterías. También, escoge una posición óptima para
poner el PAA3, antes de controlarlo con la computadora.
Instalando el Software del PAA3:
1.
Navegue a la página PAA3 en www.phonic.com y
descargue el software en la parte inferior de la página.
2.
Busque paa3_setup.exe en el archivo y haga doble
clic para comenzar la instalación.
3.
Selecciona un directorio de instalación apropiado y da
click en “next” para continuar. El software del PAA3
será instalado automáticamente.
PAA3 EN LINEA
Conexión:
1.
Después de instalar, abre el software del PAA3.
2.
Conecta el PAA3 a tu computadora vía el cable USB
incluido, luego enciende el PAA3.
3.
Ve a la opción de archivo (FILE), selecciona ON LINE
para conectarte al PAA3. La información previamente
guardada en el PAA3 será inmediatamente cargada.
4.
Tan pronto como se termine la carga, podrás operar
el PAA3 moviendo el puntero del mouse y, haciendo
click en el MENU de la pantalla para entrar a las
diferentes opciones del PAA3.
5.
Ahora el PAA3 está operando simultáneaente con
la computadora. Las funciones que sean activadas,
serán mostradas en el PAA3 y en la computadora.
6.
Ve a FILE y da click en ONLINE una vez más si tu
deseas deshabilitar la operación online del PAA3.
Utilizando el PAA3 En Línea:
El menú simple, localizado en la parte baja de menú FILE,
en la parte superior del lado izquierdo en el programa
principal del PAA3, permite a los usuarios acceder a las
funciones del PAA3. Este menú es básicamente idéntico
al del PAA3, serás capaz de navegar en este menú.
Tipo de Display:
Haciendo click en el botón SPL METER (o LEVEL METER)
a la derecha del mencionado menú, permitirá a los usuarios
cambiar el display de pantalla, entre analizador de espectro
y el display de medición.
Memorias:
La sección de Memoria, esta tomada por casi la mitad
inferior de la pantalla del programa del PAA3. Aqui se lista
todas las memorias almacenadas en el PAA3 descargadas
a la computadora. Las dos pestañas permiten al usuario ver
ya sea las memorias almacenadas del RTA o las del RT60.
Luz de Fondo:
EL boton de luz de fondo de lado derecho del programa
del PAA3, permitira a los usuarios activar remotamente la
luz de fondo del PAA3.
OPERACION SIMULTANEA CON LA COMPUTADORA
PAA3 OFF LINE
Las siguientes funciones pueden ser utilizadas mientras
se este conectado a la computadora o no, a no ser que
se indique lo contrario.
Imprimiendo:
1.
Ve a archivo (FILE), selecciona PRINT y, aparecerá
una ventana de selección de impresoras.
2.
Selecciona una impresora de la lista.
3.
Selecciona toda la información o una de las16
memorias. También se puede imprimir los datos del
RT60.
4.
Selecciona el nivel de calidad de impresión (draft,
baja calidad, calidad media o alta).
5.
Da click en imprimir y la ventana de la impresora
desaparecerá tan pronto como la transmisión sea
completada.
ATENCION: Además de los valores de la memoria de las
31 bandas y la configuración de EQ, el nombre del archivo,
fecha de impresión, Rango de Nivel, WEIGHTING y nivel
máximo también serán impreso en la hoja de datos.
Abrir Archivo:
1.
Cuando este off line, ve al menú de FILE y selecciona
“Open File” (abrir archivo)
2.
Localiza el archivo previamente guardado en la PC
y dale doble click.
3.
La informacion esta lista para ser leida, editada y,
cualquier modificacion puede hacerse.
Guardando el Archivo:
1.
Ve al menú FILE y selecciona Save File.
2.
Selecciona el directorio (o crea uno nuevo), y da
nombre al archivo.
3.
Da click en SAVE para guardar el archivo y tu sesión
completa será guardada bajo ese nombre de archivo.
Peak Hold:
1.�
Da click en ON para ver el valor pico de cada
frecuencia y de todas las frecuencias. El nivel puede
ser encontrado ya sea en el medidor de barra en el
gráfico de pico de RTA, o en el lado derecho de la
ventana de programa.
2.�
Da click en OFF para ver el valor del RTA en cada
frecuencia y en todas las frecuencias.
MEMORIA
Selecciona uno de los slots de memoria (del 1 al 10 y de
A al F) en la sección RTA, de la tabla de memoria, en el
inferior de la ventana del software del PAA3 para ver las
propiedades de la información guardada. Los usuarios
pueden dar click en la barra de medición en el espectro
para ver una lectura específica de frecuencia, o para ver
el valor de la columna RTA.
ATENCION: Los usuarios pueden renombrar cualquier
memoria al hacer doble click en el numero del slot en la
tabla de memorias.
Funciones de Memoria:
El menú de memoria (así como el de las siguientes
opciones) no esta disponible cuando el PAA3 esta en
operación On Line.
Promedio:
1.
Ve al menú de MEMORY/AVERAGE, entonces
selecciona RTA AERAGE o RT60 AVERAGE, para
activar la función promedio.
2.
Al dar click, escoge la memoria del 1 al 10 para sacar
el cálculo promedio. La configuración del rango de
nivel original se desplegara junto a su número.
3.
Da click en AVG para ejecutar el cálculo, los
resultados de esto se mostraran inmediatamente.
4.
Selecciona una memoria de A~F y, da click en
Save para guardar los resultados (el viejo será
sobreescrito), o haga click en Cancel para salir. Los
usuarios también pueden ver los resultados (ya sea
en graficas o en texto) inmediatamente ya sea en un
cuadro de resultados o en la tabla de memorias, con
el rango de nivel mostrado en la parte superior.
Configuración de EQ:
1.
Selecciona una memoria (del 1 al 10 o de A al F) con
la cual quieras ajustar el EQ.
2.
Ve a MEMORY/EQ SETTING y activa la función de
configuración de EQ.
3.
Mueve el cursor y da click en cada medidor de
barras para averiguar cuantos dB necesitas recortar
o reforzar para cada frecuencia central.
Limpiar:
1.
Ve a MEMORY y de ahí a CLEAR.
2.
Selecciona un slot de memoria de 1 a 10 y de
A~F del submenú, y la memoria será borrada
inmediatamente; selecciona “All” si necesitas limpiar
todas las memorias almacenadas.
SERVICIO Y REPARACIÓN
Para refacciones de reemplazo y reparaciones, por favor póngase en contacto con nuestro
distribuidor de Phonic en su país. Phonic no distribuye manuales de servicio directamente a los
consumidores y, avisa a los usuarios que no intenten hacer cualquier reparación por si mismo,
haciendo ésto invalidará todas las garantías del equipo. Puede encontrar un distribuidor cerca
de usted en http://www.phonic.com/where-to-buy/.
INFORMACIÓN DE LA GARANTIA
Phonic respalda cada producto que hacemos con una garantía sin enredo. La cobertura de
garantía podría ser ampliada dependiendo de su región. Phonic Corporation garantiza este
producto por un mínimo de un año desde la fecha original de su compra, contra defectos en
materiales y mano de obra bajo el uso que se instruya en el manual del usuario. Phonic, a su
propia opinión, reparará o cambiará la unidad defectuosa que se encuentra dentro de esta
garantía. Por favor, guarde los recibos de venta con la fecha de compra como evidencia de la
fecha de compra. Va a necesitar este comprobante para cualquier servicio de garantía. No se
aceptarán reparaciones o devoluciones sin un número RMA apropiado (return merchandise
autorization). En orden de tener esta garantía válida, el producto deberá de haber sido
manejado y utilizado como se describe en las instrucciones que acompañan esta garantía.
Cualquier atentado hacia el producto o cualquier intento de repararlo por usted mismo,
cancelará completamente esta garantía. Esta garantía no cubre daños ocasionados por
accidentes, mal uso, abuso o negligencia. Esta garantía es válida solamente si el producto fue
comprado nuevo de un representante/distribuidor autorizado de Phonic. Para la información
completa acerca de la política de garantía, por favor visite http://www.phonic.com/warranty/.
SERVICIO AL CLIENTE Y SOPORTE TÉCNICO
Le invitamos a que visite nuestro sistema de ayuda en línea en https://support.phonic.com/.
Ahí podrá encontrar respuestas a las preguntas más frecuentes, consejos técnicos, descarga
de drivers, instrucciones de devolución de equipos y más información de mucho interés.
Nosotros haremos todo el esfuerzo para contestar sus preguntas lo antes posible.
FCC Caution: To assure continued compliance, any changes or modifications not expressly
approved by the party responsible for compliance could void the user's authority to operate this
equipment. (Example - use only shielded interface cables when connecting to computer or
peripheral devices).
THIS DEVICE COMPLIES WITH PART 74 OF THE FCC RULES. This equipment complies with
FCC RF radiation exposure limits set forth for an uncontrolled environment.
[email protected]
http://www.phonic.com
Measurements are shown in mm/inches
DIMENSIONS DIMENSIONES
Todas las medidas están mostradas en mm/pulgadas.
45mm / 5.7"
1
39.5 / 1.6"
83mm / 3.3"