Trotec TC100 Operating Manual
| Brand: | Trotec |
| Category: | Measuring Instruments |
| Model: | TC100 (Operating Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 13 |
Text of Trotec TC100 Operating Manual
Trotec TC100 Operating manual – thermohygrometer TC100
Table of contents
Notes regarding the operating manual................................. 1
Safety..................................................................................... 1
Information about the device................................................ 2
Transport and storage........................................................... 7
Operation ...................................................
Operating manual – thermohygrometer TC100 Intended use
Only use the device for indoor temperature and humidity
measurements within the measuring range specified in the
technical data. Observe and comply with the technical data.
To use the device for its intended use, only use accessories and
spare parts which have been approved by Trotec.
Improper use
Do not use the device in potentially explosive atmospheres, for
measurements in liquids or at live
Operating manual – thermohygrometer TC100 The wet-bulb temperature (or theoretical limit of cooling) is the
lowest temperature that can be reached through direct
evaporative cooling only. It is determined by wrapping a cotton
cloth soaked with distilled water around the measuring tip or
mercury bulb of a thermometer and then exposing it to the
environment. The cooling effect achieved by the evaporated
water can thus be measured and simulated for the
Operating manual – thermohygrometer TC100 Display
%
WBGT
HIDPT
hpa
20
21
22
16
15
17
18
19
No.
Designation
15
Percentage indication
16
Measurement value display for relative humidity
17
Measurement value display for air temperature
18
Measurement value display for:
• heat index
• dew point temperature
• wet-bulb temperature
• globe temperature
• WBGT index
19
Indication of the air pressure unit:
• hpa
• inHg
• mmHg
20
Measurement val
Operating manual – thermohygrometer TC100 WBGT index
In the course of sports events, for instance, both the WBGT and
the HI index are increasingly used as an indication for a
potential physical stain and associated hazards.
Colour of
warning flag
Risk
Effect
WBGT °C WBGT °F
Black
Extreme
Overheating
above
28 °C
above
82 °F
Red
High
23 °C to
28 °C
73 °F to
82 °F
Yellow
Moderate
18 °C to
22 °C
65 °F to
72 °F
Green
Low
below
18 �
Operating manual – thermohygrometer TC100 HI index
25% 30% 35% 40% 45% 50% 55% 60% 65% 70% 75% 80% 85% 90% 95% 100%
42°
48
50
52
55
57
59
62
64
66
68
71
73
75
77
80
82
41°
46
48
51
53
55
57
59
61
64
66
68
70
72
74
76
79
40°
45
47
49
51
53
55
57
59
61
63
65
67
69
71
73
75
39°
43
45
47
49
51
53
55
57
59
61
63
65
66
68
70
72
38°
42
44
45
47
49
51
53
55
56
58
60
62
64
66
67
69
37°
40
42
44
45
47
49
51
52
54
56
58
59
61
63
65
66
36°
39
40
42
44
45
Operating manual – thermohygrometer TC100 Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
The manufacturer packed the device to the best of his abilities
to protect it against transport damages.
Storage
When the device is not being used, observe the following
storage conditions:
•
dry and protected from frost and hea
Operating manual – thermohygrometer TC100 Selecting the measuring mode
After switch-on, the device will display the globe temperature
(GT, 21). Then also indicated are the air pressure (20), the
ambient temperature (17) and the relative humidity (16). The
following measuring modes are available:
Info
With activated MAX/MIN/AVG functions you cannot
change the measuring mode. You can deactivate these
functions by pressing the MAX/MIN button (4)
r
Operating manual – thermohygrometer TC100 Switching on the background illumination
1.
Press and hold the Lamp / pressure unit button (8) for
approx. 3 seconds.
ð The background illumination is activated.
2.
Press the Lamp / pressure unit button (8) again for approx.
3 seconds to deactivate the background illumination.
Setting the indoor / outdoor function
In the WBGT measuring mode you can improve the accuracy of
your measuring results by s
Trotec Measuring Instruments Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
BP17 |
PDF User Guide (@B58I87), Trotec BP17 Measuring Instruments (13-04-2026) |
6 | 617 | 124 | 13-04-2026 | |
BX50 MID |
User Guide: Trotec BX50 MID (P4RRSK, Upd.25-06-2026) |
8 | 1065 | 267 | 25-06-2026 | |
MultiMeasure Basic BA15 |
MultiMeasure Basic BA15 Operating manual - I9A386 |
36 | 709 | 128 | 01-06-2026 | |
bz30 |
PDF Manual (@87UY21), Trotec bz30 Measuring Instruments (17-08-2026) |
200 | 908 | 137 | 17-08-2026 | |
BE44 |
Trotec Measuring Instruments Operating manual (File: PDF, 30-09-2026) |
13 | 497 | 90 | 30-09-2026 | |
BM20 |
BM20 Operating manual - 978RR5 |
108 | 1443 | 318 | 30-08-2026 | |
ProMarker OEM |
User Manual: Trotec ProMarker OEM (W3966P, Upd.14-09-2026) |
65 | 702 | 120 | 14-09-2026 | |
BT22WP |
PDF User Guide (@1RDQ72), Trotec BT22WP Measuring Instruments (01-06-2026) |
10 | 384 | 85 | 01-06-2026 |