Operating manual – dehumidifier TTP 5 E / TTP 10 E

Table of contents Notes regarding the operating manual................................. 1 Safety..................................................................................... 1 Information about the device................................................ 3 Transport and storage........................................................... 4 Assembly and installation..................................................... 5 Operation ............................................................................... 6 Errors and faults.................................................................... 6 Maintenance .......................................................................... 7 Technical annex................................................................... 10 Disposal ............................................................................... 10 Notes regarding the operating manual Symbols Warning of electrical voltage This symbol indicates dangers to the life and health of persons due to electrical voltage. Warning This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death. Caution This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury. Notice This signal word indicates important information (e.g. material damage), but does not indicate hazards. Info Information marked with this symbol helps you to carry out your tasks quickly and safely. Follow the manual Information marked with this symbol indicates that the operating manual must be observed. You can download the current version of the operating manual and the EU declaration of conformity via the following link: TTP 5 E https://hub.trotec.com/?id=41289 TTP 10 E https://hub.trotec.com/?id=41290 Safety Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use! Warning Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and / or serious injury. Save all warnings and instructions for future reference. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. • Do not use the device in potentially explosive rooms. • Do not use the device in aggressive atmosphere. • Set the device up in an upright and stable position. • Let the device dry out after a wet clean. Do not operate it when wet. • Do not use the device with wet or damp hands. • Do not expose the device to directly squirting water. • Never insert any objects or limbs into the device. • Do not cover or transport the device during operation. • Do not sit on the device.

Operating manual – dehumidifier TTP 5 E / TTP 10 E

• This appliance is not a toy! Keep away from children and animals. Do not leave the device unattended during operation. • Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts. • Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged! • The electrical connection must correspond to the specifications in chapter Technical data. • Insert the mains plug into a properly secured mains socket. • Observe the device's power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload. • Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so. • Switch the device off and disconnect the power cable from the mains socket when the device is not in use. • Do not under any circumstances use the device if you detect damages on the mains plug or power cable. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Defective power cables pose a serious health risk. • When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter. • Ensure that the air inlet and outlet are not obstructed. • Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects. • Only transport the device in an upright position with an emptied condensation tank or drain hose. • Discharge the collected condensate before transport and storage. Do not drink it. Health hazard! Intended use Only use the device for keeping the room air in spatially limited areas dry whilst adhering to the technical data. Intended use includes keeping the following dry: • small living spaces • closets and shoe cabinets • bookshelves • pantries and storerooms • small, windowless bathrooms etc. Improper use • Do not place the device on wet or flooded ground. • Do not place any objects, e.g. clothing, on the device. • Do not use the device outdoors. • Any unauthorised modifications, alterations or structural changes to the device are forbidden. • Any operation other than as described in this manual is prohibited. Non-observance renders all claims for liability and guarantee null and void. Personnel qualifications People who use this device must: • be aware of the dangers that occur when working with electric devices in damp areas. • have read and understood the operating manual, especially the Safety chapter. Maintenance tasks which require the housing to be opened must only be carried out by specialist electrical companies or by Trotec. Residual risks Warning of electrical voltage Work on the electrical components must only be carried out by an authorised specialist company! Warning of electrical voltage Before any work on the device, remove the mains plug from the mains socket! Hold onto the mains plug while pulling the power cable out of the mains socket. Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications! Warning The device is not a toy and does not belong in the hands of children. Warning Risk of suffocation! Do not leave the packaging lying around. Children may use it as a dangerous toy. Notice Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

Operating manual – dehumidifier TTP 5 E / TTP 10 E

Behaviour in the event of an emergency 1. Switch the device off. 2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket. 3. Do not reconnect a defective device to the mains. Information about the device Description of the device The device uses the principle of condensation and a Peltier element to dehumidify small rooms in a silent manner. The fan sucks in damp room air through the air inlet. The room air is cooled at the cold side of the Peltier element until it is below the dew point. Water vapour contained in the room air precipitates as condensation or rime. The dehumidified, cooled air is blown out. The drier air thus conditioned mixes with the air in the room. The humidity in the room where the device is positioned is reduced as air constantly circulates through the device. Depending on the air temperature and the relative humidity, the condensed water drops into the condensation tank. The latter is fitted with a float to measure the filling level. If the maximum level of the condensation tank is reached or if the float is not correctly positioned, the indicator LED will light up orange. The device switches off. The LED only goes out again once the emptied condensation tank is reinserted. The functioning of the two devices is identical, they only differ in terms of their technical data. Info The TTP 10 E is additionally equipped with a removable air filter. Instructions and notes regarding the air filter only refer to the TTP 10 E. Device depiction TTP 5 E 6 4 1 2 3 5

Operating manual – dehumidifier TTP 5 E / TTP 10 E

TTP 10 E 2 1 3 8 5 6 9 7 No. Designation 1 On/off switch (LED-illuminated) 2 Air inlet 3 Condensation tank 4 Power adapter 5 Mains connection 6 Air outlet 7 Handle 8 Power cable 9 Air filter (TTK 10 E only) Transport and storage Notice If you store or transport the device improperly, the device may be damaged. Note the information regarding transport and storage of the device. Transport Before transporting the device, observe the following: • Switch the device off. • Hold onto the mains plug while pulling the power cable out of the mains socket. • Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance). • Do not use the power cable to drag the device. After transporting the device, observe the following: • Set up the device in an upright position after transport. Storage Before storing the device, proceed as follows: • Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance). • Empty and clean the condensation tank prior to storage. When the device is not being used, observe the following storage conditions: • dry and protected from frost and heat • in an upright position where it is protected from dust and direct sunlight • with a cover to protect it from invasive dust if necessary • Place no further devices or objects on top of the device to prevent it from being damaged.

Operating manual – dehumidifier TTP 5 E / TTP 10 E

Assembly and installation Scope of delivery • 1 x Device • 1 x Power adapter (TTP 5 E) • 1 x Power cable (TTP 10 E) • 1 x Air filter (TTK 10 E only) • 1 x Manual Unpacking the device 1. Open the cardboard box and take the device out. 2. Completely remove the packaging. 3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding. Start-up When positioning the device, observe the minimum distance from walls or other objects as described in the Technical data chapter. A B C C D • Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service. • Set the device up in an upright and stable position. • Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges. • Make sure that extension cables are completely unrolled. • When positioning the device, keep a sufficient distance to heat sources. • Make sure that no curtains or other objects interfere with the air flow. • When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations. Inserting the air filter Notice Do not operate the device without an inserted air filter! Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device. • Make sure that the air filter is installed before switching the device on. TTP 10 E Inserting the condensation tank • Ensure that the float inside the condensation tank is inserted correctly. • Ensure that the condensation tank is empty and inserted correctly.

Operating manual – dehumidifier TTP 5 E / TTP 10 E

Connecting the power cable / power adapter • Plug the cable's device plug into the device's mains connection. • Plug the power adapter or power cable into a properly fused mains socket. Operation • Avoid open doors and windows. • After being switched on, the device operates fully automatically. Operating elements 10 1 No. Designation 1 On/off switch 10 Indicator LED: illuminated in green when the device is ready for operation illuminated in orange when the water tank is full or the float is incorrectly positioned Switching the device on Once you have completely installed the device as described in the Start-up chapter, you can switch it on. Warning of electrical voltage Do not remove the condensation tank from the device during operation. The device keeps running even if the condensation tank is not inserted! Otherwise, water may drop from the device uncontrollably and damage the device. There is a risk of electric shock! 1. Press the on/off switch (1). ð The LED at the on/off switch is illuminated in green. ð The fan switches on. ð The device starts to dehumidify. Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands. • Hold onto the mains plug while pulling the power cable out of the mains socket. • Empty the condensation tank, if need be. • Clean the device according to the Maintenance chapter. • Store the device according to the Storage chapter. Errors and faults The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list. The device does not start: • Check the power connection. • Check the power cable and mains plug for damages. • Check the on-site fusing. • Check the condensation tank for correct seating. • Check whether the condensation tank is full. The indicator LED (10) is illuminated in orange. • Check the room temperature. Observe the device's permissible operating range according to the technical data. • Wait for 10 minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec.

Operating manual – dehumidifier TTP 5 E / TTP 10 E

The device is running, but there is no formation of condensate: • Check the float in the condensation tank for dirt. If necessary, clean the condensation tank. The float must be able to move freely. • Check the room temperature. Observe the device's permissible ambient temperature according to the technical data. • Ensure that the relative room humidity complies with the technical data. • Check the air filter for dirt. If necessary, clean or replace the air filter. The device is loud or vibrates: • Check whether the device is set up in a stable and upright position. Condensate is leaking: • Check the device for leaks. The device gets very warm, is loud or loses power: • Check the air inlets and air filters for dirt. Remove external dirt. • From the outside, check the device for dirt (see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company or by Trotec. Notice Wait for at least 3 minutes after maintenance and repair work. Only then switch the device back on. Your device still does not operate correctly after these checks? Please contact the customer service. If necessary, bring the device to an authorized specialist electrical company or to Trotec for repair. Maintenance Activities required before starting maintenance Warning of electrical voltage Do not touch the mains plug with wet or damp hands. • Switch off the device. • Hold onto the mains plug while pulling the power cable out of the mains socket. Cleaning the housing Clean the housing with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth. Visual inspection of the inside of the device for dirt 1. Remove the air filter. 2. Use a torch to illuminate the openings of the device. 3. Check the inside of the device for dirt. 4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company or by Trotec. 5. Put the air filter back in.

Operating manual – dehumidifier TTP 5 E / TTP 10 E

Cleaning the air filter The following maintenance task only needs to be carried out for the device TTP 10 E. Notice Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be deformed or rounded. Before reinserting the air filter, make sure that it is undamaged and dry! The air filter has to be cleaned as soon as it is dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults). 1. Remove the air filter from the device. TTP 10 E 2. Clean the filter using a slightly damp, soft, lint-free cloth. If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent. 3. Allow the filter to dry completely. Do not insert a wet filter into the device! 4. Reinsert the air filter into the device. TTP 10 E

Operating manual – dehumidifier TTP 5 E / TTP 10 E

Emptying the condensation tank If the condensation tank is full, the indicator LED (10) lights up orange. The device switches off. 1. Take the condensation tank out of the device. 11 2. Remove the rubber stopper (11) from the condensation tank. 3. Empty the condensation tank over a drain or sink. 4. Put the rubber stopper (11) back in. 5. Rinse the tank with clear water. Clean the tank regularly using a mild cleaning agent (no detergent!). 6. Refit the condensation tank into the device. Make sure not to damage the float when inserting or removing the condensation tank. In doing so, make sure that the float is positioned correctly. In doing so, make sure that the condensation tank is inserted correctly, for otherwise the device cannot be switched back on. Activities required after maintenance If you want to continue using the device: • Reconnect the device to the mains. If you do not intend to use the device for a considerable time: • Store the device according to the Storage chapter.

Operating manual – dehumidifier TTP 5 E / TTP 10 E

Technical annex Technical data Parameter Value Model TTP 5 E TTP 10 E Max. dehumidification performance 300 ml / 24 h 750 ml / 24 h Ambient temperature 10 °C to 50 °C 10 °C to 50 °C Mains connection Power adapter Input: 100 V – 240 V / 50 – 60 Hz Output: DC 9 V / 2.5 A 100 V – 240 V / 50 – 60 Hz Power consumption 20 W 65 W Nominal current 2.5 A 2.5 A Condensation tank capacity 700 ml 2000 ml Sound pressure level (1 m distance) 35 dB(A) 45 dB(A) Dimensions (depth x width x height) 100 x 160 x 260 mm 130 x 220 x 370 mm Minimum distance to walls and other objects top (A): rear (B): sides (C): front (D): 10 cm 10 cm 10 cm 10 cm 10 cm 10 cm 10 cm 10 cm Weight 1.5 kg 2 kg Disposal The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. For further return options provided by us please refer to our website www.trotec24.com. The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.

Trotec GmbH & Co. KG

Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 [email protected] www.trotec.com