Extech Instruments CMM-17 Quick Start Manual

Brand: Extech Instruments
Category: Multimeter
Model: CMM-17 (Quick Start Manual)
File Type: PDF
File Size: —
Pages: 10
Text of Extech Instruments CMM-17 Quick Start Manual

MAX AVGMIN ACDC

SHIFT SCAN Remote JK TE RS OUT SBY 88888 ms Level ACDC C F kHz 4-200-20 µm sec AV µm sec AV AUTO Quick Start CMM-17 Process Calibrator Multimeter • Constant Voltage • mA Source • Square Wave • Auto Scan/Ramp • Dual Display Multimeter • Rechargeable Batteries This guide provides an overview of the meter. For more detailed information, refer to the CMM-17 User’s Guide provided with

Extech Instruments CMM-17 This process calibrator/meter is a hand-held, battery-operated instrument for testing and

troubleshooting power electronic systems. This device can be used not only for instrument system maintenance, but also for maintaining, servicing industrial meters, testing electronic circuits and electronic equipments. The meter can also be used to measure or calibrate sensors or transmitters in automotive or automatic control system. The meter generates

A WARNING identifies conditions and actions that may cause hazard(s) to the user;

A CAUTION identifies conditions and actions that may damage this Device. Table-1 International Electrical Symbols AC - Alternating Current DC - Direct Current AC and DC - Alternating and Direct Current Ground Double Insulation See Explanation In The Manual To avoid electric shock, injury, or damage to this instrument: • Read this operation manual complete

Extech Instruments CMM-17 Setup and Output a process calibration signal

1. Set the side switch on the left side to the M/S position 2. Turn the function switch to select combined function for the output function required ( , mA, or V) and related input function will be used simultaneously. 3. Press the “SHIFT” button to shift the buttons for output setting. 4. Use the arrow buttons (3/ 4for digit selection, 5/ 6 for value) to set the output value. 5. Connect the OUTPUT terminal

ms Level ACDC

C F kHz 4-200-20 µ m sec AV µm sec AV AUTO INPUT- ACV and Frequency Measurements 1. Set the side switch on the left side to the M or M/S position 2. Turn the rotary switch to select combined function for “V” and the output function ( , mA or V) as desired. 3. Press the “AC/DC” button momentarily to select AC voltage measurement.

Figure-3 LCD Display

1. Remote control 2. Thermocouple type 3. Output enable/disable 4. Secondary display for output and input 5. Constant voltage output 6. Square wave output for Hz 7. Square wave output for % 8. Square wave output for mS 9. Output/input units 10. Scan output 11. Ramp output 12. Shift button operation 13. Diode/audible continuity 14. Auto range 15. Relative mode 16. Low battery 17. Auto power off ic

Extech Instruments Multimeter Owners Instructions: