Extech Instruments MN25 Operation & User’s Manual

Brand: Extech Instruments
Category: Multimeter
Model: MN25 (Operation & User’s Manual)
File Type: PDF
File Size: —
Pages: 15
Text of Extech Instruments MN25 Operation & User’s Manual

Extech Instruments MN25 MN25 Version 2.2 Aug 2003

2 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890- 7440 ext. 210 for authorization or visit our website at www.exte
MN25 Version 2.2 Aug 2003 3 Safety This meter has been designed for safe use, but must be operated with caution. The rules listed below must be carefully followed for safe operation. 1. NEVER apply voltage or current to the meter that exceeds the specified maximum: Input Limits Function Maximum Input V DC, V AC 600V DC/AC, 200Vrms on 200mV range mA DC 200mA 250V fast acting fuse A DC, A AC 10A 250V fast acting fuse(30 seconds max every 15 minutes) Resistan
MN25 Version 2.2 Aug 2003 4 Safety Symbols NEVER operate the meter unless the back cover and the battery and fuse doors are in place and fastened securely. This symbol adjacent to another symbol, terminal or operating device indicates that the operator must refer to an explanation in the Operating Instructions to avoid personal injury or damage to the meter. This WARNING symbol indicates a potentially hazardous situation, which if not avoided, could result
MN25 Version 2.2 Aug 2003 5 Specifications Function Range Resolution Accuracy 200mV 0.1mV 2000mV 1mV 20V 0.01V 200V 0.1V DC Voltage (V DC) 600V 1V ± (0.5% reading + 2 digits) 200V 0.1V AC Voltage (V AC) 600V 1V ± (1.5% reading + 5 digits (Frequency 50/60Hz) 200mA 100µA ± (1.2% reading + 2 digits) DC Current (A DC) 10A 10mA ± (2.0% reading + 2 digits) 200mA 100µA ± (1.8% reading + 5 digits) AC Current (A AC) 10A 10mA ± (3.0% reading + 5 digits) 2
MN25 Version 2.2 Aug 2003 6 Display 3 ½ digit, 2000 count LCD, 0.5” digits Overrange indication “1” is displayed Diode Test Test current of 1mA maximum, open circuit voltage 2.8V DC typical Continuity Check Audible signal will sound if the resistance is less than approximately 30Ω Battery Test current 9V (6mA); 1.5V (100mA) Input Impedance >1MΩ ACV Bandwidth 45Hz to 450Hz DCA voltage drop 200mV Polarity Automatic (no indication for positive pola
MN25 Version 2.2 Aug 2003 7 Meter Description 1. LCD Display 2. Function switch 3. 10A jack 4. COM jack 5. Positive jack Note: Tilt stand, fuse and battery compartment are on rear of unit. LCD Display Indicators •))) Continuity Diode test m milli ( volts, amps) k kilo (ohms) Ω ohms V DC volts direct current V AC volts alternating current A DC amps direct current A AC amps alternating current BAT Low battery and battery test 1 2 5 3 4 5
MN25 Version 2.2 Aug 2003 8 Operation WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great care. 1. ALWAYS turn the function switch to the OFF position when the meter is not in use. 2. If “OL” appears in the display during a measurement, the value exceeds the range you have selected. Change to a higher range. NOTE: On some low AC and DC voltage ranges, with the test leads not connec
MN25 Version 2.2 Aug 2003 9 AC Voltage Measurements WARNING: Risk of Electrocution. The probe tips may not be long enough to contact the live parts inside some 240V outlets for appliances because the contacts are recessed deep in the outlets. As a result, the reading may show 0 volts when the outlet actually has voltage on it. Make sure the probe tips are touching the metal contacts inside the outlet before assuming that no voltage is present. CAUTION: D

Extech Instruments Multimeter Owners Instructions: