Read the Dometic 541815 Installation Instructions Manual online using the built-in PDF viewer.

Text of the manual

Read these instructions carefully. These

instructions MUST stay with this product. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA SERVICE CENTER & DEALER LOCATIONS Please Visit: www.eDometic.com Roof Top Unit Used With 3314850.000 Air Distribution Box Description Model Board Built In OR Electronic Control Kit Thermostat Optional Indoor Temperature Sensor Air Conditioner CCC 2 Controls 541815, 541816 641815, 641816 Board Built In 3314082.000 CCC2-Blk 3314082.011 CCC2-Wht 3311931.000-20′ 3311931.012-40′ 3311931.020-60′ 457915, 459516 459530, 540315 540316, 640312 640315, B57915 B59516, B59530 B57935, B59536 3312020.000 CCC 2 Controls W/Electric Heat 641835 Board Built In LCD SZ Controls 541915 541916 641915 641916 Board Built In 3313192.000 C/F-Wht 3313192.019 C/F-Blk N/A 457915, 459516 540315, 540316 B57915, B59516 3313189.000 C/F-Wht 3313189.015 C/F-Blk 3313189.049 C/F/HS-Wht 3313189.056 C/F/HS-Blk Thermostat Included With Electronic Control Kit 640312, 640315 459530, B59530 3313189.000 C/F-Wht 3313189.015 C/F-Blk B57935, B59536 3313189.049 C/F/HS-Wht 3313189.056 C/F/HS-Blk LCD SZ Controls W/Electric Heat 641935 Board Built In 3313194.000 C/F/HS-Wht 3313194.015 C/F/HS-Blk Heat Pump CCC 2 Controls 551816 651815 651816 Board Built In 3314082.000 CCC2-Blk 3314082.011 CCC2-Wht 3311931.000-20’ 3311931.012-40’ 3311931.020-60’ 459186, B59186 3312020.000 LCD SZ Controls 551916 651916 Board Built In 3313193.000 C/F/HP-Wht 3313193.017 C/F/HP-Blk N/A 459196 B59196 3313189.064 C/F/HP-Wht 3313189.072 C/F/HP-Blk Thermostat Included With Electronic Control Kit This Unit is designed for OEM installation. RECORD THIS INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number ADB Model Number ADB Serial Number Date Purchased REVISION B Form No. 3315085.000 1/14 (French 3315442.000_B) ©2014 Dometic Corporation LaGrange, IN 46761 INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS

INTRODUCTION.....................................................................................................................................................................2 DOCUMENT SYMBOLS.........................................................................................................................................................2 IMPORTANT SAFETY INSTRUCTIONS.................................................................................................................................3 A. Recognize Safety Information....................................................................................................................................3 B. Understand Signal Words...........................................................................................................................................3 C. Supplemental Directives.............................................................................................................................................3 D. General Safety Messages..........................................................................................................................................3 SPECIFICATIONS...................................................................................................................................................................4 A. Table - Unit Data.........................................................................................................................................................4 B. Roof Requirements.....................................................................................................................................................5 INSTALLATION INSTRUCTIONS...........................................................................................................................................6 A. Choosing Proper Location For Unit............................................................................................................................6 B. Roof Preparation........................................................................................................................................................7 C. Wiring Requirements..................................................................................................................................................8 D. Choosing Thermostat Location...................................................................................................................................9 E. Thermostat, Optional Indoor Temperature Sensor & Thermostat Communication Cable Installation .......................9 F. Placing Unit On Roof................................................................................................................................................10 G. Installation Preparation............................................................................................................................................ 11 H. 120 Vac Power Supply Connection.......................................................................................................................... 11 I. 120 Vac Power Supply Connection For 541X1XA, 551X16A, 6418XXH, & 65181XH Models................................12 J. Duct Divider Installation............................................................................................................................................14 K. LCD SZ System Low Voltage Wire Connections......................................................................................................14 L. CCC 2 System Low Voltage Wire Connections........................................................................................................15 M. (CCC 2 System Only) Configuration.........................................................................................................................16 N. Installing Unit............................................................................................................................................................17 O. Installing ADB...........................................................................................................................................................18 P. (CCC 2 System Only) Reset & Checkout.................................................................................................................19 Q. (CCC 2 System Only) Furnace/Aqua Temperature Differential Setting....................................................................20 GENERAL INFORMATION....................................................................................................................................................20 A. Heat Gain.................................................................................................................................................................20 B. Condensation...........................................................................................................................................................20 WIRING DIAGRAMS.............................................................................................................................................................21 A. Simple RV Wiring Diagram.......................................................................................................................................21 B. Unit Wiring Diagrams................................................................................................................................................21 C. Electronic Control Kit Wiring Diagrams....................................................................................................................23 DOCUMENT SYMBOLS Indicates additional information that is NOT related to physical injury. Indicates step-by-step instructions. INTRODUCTION This air conditioner/heat pump (hereinafter referred to as “unit” or “product”) is designed and intended for installation on the roof of a Recreational Vehicle (RV) during the time it is manufactured. Read these instructions and highlight the appropriate steps for your particular procedure before starting the installation. This unit can be installed by one person with brief help from additional personnel. Use these instructions to ensure a properly installed, and properly functioning product. Dometic Corporation reserves the right to modify appearances and specifications without notice.

IMPORTANT SAFETY INSTRUCTIONS

This manual has safety information and instructions to help users eliminate or reduce the risk of accidents and injuries. A. Recognize Safety Information This is the safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. B. Understand Signal Words A signal word will identify safety messages and property damage messages, and will indicate the degree or level of hazard seriousness.  indicates a hazardous situation that, if NOT avoided, could result in death or serious in- jury.  indicates a hazardous situation that, if NOT avoided, could result in minor or moderate injury.  is used to address practices NOT related to physical injury. C. Supplemental Directives Read and follow all safety information and instructions to avoid possible injury or death. Read and understand these instructions be- fore [installing / using / servicing / performing maintenance on] this product. Incorrect [installation / operation / servicing / maintaining] of this product can lead to seri- ous injury. Follow all instructions. The installation MUST comply with all ap- plicable local or national codes, including the latest edition of the following standards: U.S.A. ● ●ANSI/NFPA70, National Electrical Code (NEC) ● ●ANSI/NFPA 1192, Recreational Vehicles Code CANADA ● ●CSA C22.1, Parts l & ll, Canadian Electri- cal Code ● ●CSA Z240 RV Series, Recreational Vehicles D. General Safety Messages  Failure to obey the following warn- ings could result in death or serious injury: ● ●This product MUST be [installed / serviced] by a qualified service technician. ● ●Do NOT modify this product in any way. Modifica- tion can be extremely hazardous. ● ●Do NOT add any devices or accessories to this product except those specifically authorized in writing by Dometic Corporation.

Table - Unit Data

Model No. Nominal Capacity (BTU HR) Cooling Electrical Rating Compressor Rated Load Amps Compressor Locked Rotor Amps Fan Motor Rated Load Amps Fan Motor Locked Rotor Amps Refrigerant R-410A (oz) Minimum Wire Size* AC Circuit Protection ***Installer Supplied Minimum Generator Size** 1 Unit / 2 Units 457915.70X 13,500 120 Vac 60 Hz 1 ph 12.4 63.0 2.5 5.8 18.0 12 AWG Copper Up to 24' 20 Amp 3.5 kW / 5.0 kW 457915.71X 13,500 12.4 68.0 2.5 5.8 18.0 20 Amp 3.5 kW / 5.0 kW B57915.71X 13,500 12.4 68.0 2.5 5.8 16.0 20 Amp 3.5 kW / 5.0 kW B57935.71X 13,500 12.7 68.0 2.7 5.8 16.0 20 Amp 3.5 kW / 5.0 kW 459186.70X 15,000 13.3 66.0 2.0 5.6 29.0 20 Amp 3.5 kW / 5.0 kW 459186.71X 15,000 13.3 70.0 2.0 5.6 29.0 20 Amp 3.5 kW / 5.0 kW 459186E71X 15,000 13.3 70.0 2.0 5.6 29.0 20 Amp 3.5 kW / 5.0 kW B59186.71X 15,000 13.3 70.0 2.0 5.6 29.0 20 Amp 3.5 kW / 5.0 kW 459196.70X 15,000 13.3 66.0 2.0 5.6 29.0 20 Amp 3.5 kW / 5.0 kW 459196.71X 15,000 13.3 70.0 2.0 5.6 29.0 20 Amp 3.5 kW / 5.0 kW 459196E71X 15,000 13.3 70.0 2.0 5.6 29.0 20 Amp 3.5 kW / 5.0 kW B59196.71X 15,000 13.3 70.0 2.0 5.6 29.0 20 Amp 3.5 kW / 5.0 kW 459516.70X 15,000 13.3 66.0 2.0 5.6 27.5 20 Amp 3.5 kW / 5.0 kW 459516.71X 15,000 13.3 70.0 2.0 5.6 27.5 20 Amp 3.5 kW / 5.0 kW 459516E71X 15,000 13.3 70.0 2.0 5.6 27.5 20 Amp 3.5 kW / 5.0 kW B59516.71X 15,000 13.3 70.0 2.0 5.6 27.5 20 Amp 3.5 kW / 5.0 kW 459530.70X N/A 8.6 50.0 2.5 5.8 20.0 15 Amp 2.5 kW / 4.0 kW B59530.71X N/A 8.6 50.0 2.5 5.8 20.0 15 Amp 2.5 kW / 4.0 kW B59536.71X 15,000 13.2 70.0 2.7 5.6 22.0 20 Amp 3.5 kW / 5.0 kW 540315.70X 13,500 12.4 63.0 3.0 8.5 18.5 20 Amp 3.5 kW / 5.0 kW 540315.71X 13,500 12.4 68.0 3.0 8.5 18.5 20 Amp 3.5 kW / 5.0 kW 540316.70X 15,000 13.3 66.0 2.8 7.6 29.5 20 Amp 3.5 kW / 5.0 kW 540316.71X 15,000 13.3 70.0 2.8 7.6 29.5 20 Amp 3.5 kW / 5.0 kW 541815A70X 13,500 12.4 63.0 3.0 8.5 18.5 20 Amp 3.5 kW / 5.0 kW 541815A71X 13,500 12.4 68.0 3.0 8.5 18.5 20 Amp 3.5 kW / 5.0 kW 541816A70X 15,000 13.3 66.0 2.8 7.6 29.5 20 Amp 3.5 kW / 5.0 kW 541816A71X 15,000 13.3 70.0 2.8 7.6 29.5 20 Amp 3.5 kW / 5.0 kW 541915A70X 13,500 12.4 63.0 3.0 8.5 18.5 20 Amp 3.5 kW / 5.0 kW 541915A71X 13,500 12.4 68.0 3.0 8.5 18.5 20 Amp 3.5 kW / 5.0 kW 541916A70X 15,000 13.3 66.0 2.8 7.6 29.5 20 Amp 3.5 kW / 5.0 kW 541916A71X 15,000 13.3 70.0 2.8 7.6 29.5 20 Amp 3.5 kW / 5.0 kW 551816.70X 15,000 12.8 60.0 2.8 7.6 29.5 20 Amp 3.5 kW / 5.0 kW 551816.71X 15,000 12.8 70.0 2.8 7.6 29.5 20 Amp 3.5 kW / 5.0 kW 551816A70X 15,000 12.8 60.0 2.8 7.6 29.5 20 Amp 3.5 kW / 5.0 kW 551816A71X 15,000 12.8 70.0 2.8 7.6 29.5 20 Amp 3.5 kW / 5.0 kW 551916A71X 15,000 12.8 70.0 2.8 7.6 29.5 20 Amp 3.5 kW / 5.0 kW 640312.80X 11,000 11.5 53.0 2.6 8.5 20.0 20 Amp 3.5 kW / 5.0 kW 640312.83X 11,000 12.5 63.0 2.6 8.5 18.0 20 Amp 3.5 kW / 5.0 kW 640312C35X 11,000 10.5 53.0 3.5 10.0 19.0 20 Amp 3.5 kW / 5.0 kW 640312C85X 11,000 11.5 53.0 2.6 8.5 20.0 20 Amp 3.5 kW / 5.0 kW 640315.80X 13,500 12.6 63.0 2.6 8.5 18.0 20 Amp 3.5 kW / 5.0 kW 640315.83X 13,500 12.5 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 640315.84X 13,500 12.5 63.0 3.5 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 640315C35X 13,500 12.5 61.0 3.5 10.0 17.5 20 Amp 3.5 kW / 5.0 kW 640315C75X 13,500 12.7 52.0 2.6 8.5 14.5 20 Amp 3.5 kW / 5.0 kW 640315C85X 13,500 12.6 63.0 2.6 8.5 18.0 20 Amp 3.5 kW / 5.0 kW 641815.80X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 641815C35X 13,500 12.5 61.0 3.5 10.0 17.5 20 Amp 3.5 kW / 5.0 kW 641815C75X 13,500 12.7 52.0 2.6 8.5 14.5 20 Amp 3.5 kW / 5.0 kW 641815C85X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 641815H75X 13,500 12.7 52.0 2.6 8.5 14.5 20 Amp 3.5 kW / 5.0 kW SPECIFICATIONS

1 Unit / 2 Units

641815H85X 13,500 120 Vac 60 Hz 1 ph 12.6 63.0 2.6 8.5 19.0 12 AWG Copper Up to 24' 20 Amp 3.5 kW / 5.0 kW 641816.80X Hi Cap 13.4 63.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW 641816C35X Hi Cap 12.3 61.0 3.3 8.5 23.0 20 Amp 3.5 kW / 5.0 kW 641816C75X Hi Cap 12.9 52.0 2.6 8.5 21.5 20 Amp 3.5 kW / 5.0 kW 641816C85X Hi Cap 13.4 63.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW 641816H75X HI Cap 12.9 52.0 2.6 8.5 21.5 20 Amp 3.5 kW / 5.0 kW 641816H85X Hi Cap 13.4 63.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW 641835.80X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 641835C35X 13,500 12.5 61.0 3.5 10.0 17.5 20 Amp 3.5 kW / 5.0 kW 641835C75X 13,500 12.7 52.0 2.6 8.5 14.5 20 Amp 3.5 kW / 5.0 kW 641835C85X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 641835H75X 13,500 12.7 52.0 2.6 8.5 14.5 20 Amp 3.5 kW / 5.0 kW 641835H85X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 641915.80X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 641915C35X 13,500 12.5 61.0 3.5 10.0 17.5 20 Amp 3.5 kW / 5.0 kW 641915C75X 13,500 12.7 52.0 2.6 8.5 14.5 20 Amp 3.5 kW / 5.0 kW 641915C85X 13,500 12.6 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 641916.80X Hi Cap 13.4 63.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW 641916C35X Hi Cap 12.3 61.0 3.3 8.5 23.0 20 Amp 3.5 kW / 5.0 kW 641916C75X Hi Cap 12.9 52.0 2.6 8.5 21.5 20 Amp 3.5 kW / 5.0 kW 641916C85X Hi Cap 13.4 63.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW 641935.80X 13,500 12.5 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 641935C35X 13,500 12.5 61.0 3.5 10.0 17.5 20 Amp 3.5 kW / 5.0 kW 641935C75X 13,500 12.7 52.0 2.6 8.5 14.5 20 Amp 3.5 kW / 5.0 kW 641935C85X 13,500 12.5 63.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 651815.80X 13,500 13.1 63.0 2.6 8.5 24.0 20 Amp 3.5 kW / 5.0 kW 651815C35X 13,500 12.5 61.0 3.5 10.0 25.0 20 Amp 3.5 kW / 5.0 kW 651815C75X 13,500 12.7 52.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 651815C85X 13,500 13.1 63.0 2.6 8.5 24.0 20 Amp 3.5 kW / 5.0 kW 651815H75X 13,500 12.7 52.0 2.6 8.5 19.0 20 Amp 3.5 kW / 5.0 kW 651815H85X 13,500 13.1 63.0 2.6 8.5 24.0 20 Amp 3.5 kW / 5.0 kW 651816.80X HI Cap 13.4 63.0 2.6 8.5 27.0 20 Amp 3.5 kW / 5.0 kW 651816C35X HI Cap 12.3 61.0 3.3 8.5 24.0 20 Amp 3.5 kW / 5.0 kW 651816C75X Hi Cap 13.0 52.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW 651816C85X HI Cap 13.4 63.0 2.6 8.5 27.0 20 Amp 3.5 kW / 5.0 kW 651816H75X Hi Cap 13.0 52.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW 651816H85X HI Cap 13.4 63.0 2.6 8.5 27.0 20 Amp 3.5 kW / 5.0 kW 651916.80X HI Cap 13.4 63.0 2.6 8.5 27.0 20 Amp 3.5 kW / 5.0 kW 651916C35X HI Cap 12.3 61.0 3.3 8.5 24.0 20 Amp 3.5 kW / 5.0 kW 651916C75X Hi Cap 13.0 52.0 2.6 8.5 23.0 20 Amp 3.5 kW / 5.0 kW 651916C85X HI Cap 13.4 63.0 2.6 8.5 27.0 20 Amp 3.5 kW / 5.0 kW * For wire length over 24 ft., consult the National Electrical Code for proper sizing. ** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered. Keep in mind generators lose power at high altitudes and from lack of maintenance. *** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required. B. Roof Requirements ● ● A 14-1/4″ x 14-1/4″ (±1/8″) square opening (hereinafter referred to as “roof opening”) is required for installing this unit. This opening is part of the return air system of the unit and MUST be finished in accordance with NFPA 1192. ● ● Roof construction with rafters/joists support frames on a minimum of 16 inch centers. ● ● Minimum of 2 inches and maximum of 4 inches distance between roof to ceiling of RV. SPECIFICATIONS

Choosing Proper Location For Unit

This unit is specifically designed for installation on the roof of a recreational vehicle (RV). When determining your cooling requirements, the following should be considered: ● ● Size of RV; ● ● Window area (increases heat gain); ● ● Amount of insulation in walls and roof; ● ● Geographical location where the RV will be used; ● ● Personal comfort level required. 1. For one unit installation: The unit should be mounted slightly forward of center (front to back) and centered from side to side. 2. For two unit installations: Install one unit 1/3 and one unit 2/3’s from front of RV and centered from side to side. It is preferred that the unit be installed on a relatively flat and level roof section measured with the RV parked on a level surface. See table below for maximum acceptable tilt. Model Number Max Tilt Model Number Max Tilt Model Number Max Tilt 457915 B57915 B57935 459186 B59186 459196 B59196 459516 B59516 459530 15° B59530 B59536 540315 540316 541815 541816 541915 541916 551816 551916 15° 640312 640315 641815 641816 641835 641915 641916 641935 651815 651816 651916 8° 3. After Location Has Been Selected: a. Check for obstructions in the area where unit will be installed. See (FIG. 1), (FIG. 2), (FIG. 3), (FIG. 4), & (FIG. 5). Model 457915 459186 459196 459516 459530 29-7/8″ 34-7/8″ 13-1/8″ 18″ Front Dimensions Are Nominal FIG. 1 Keep This Area Free Of Obstructions Roof Opening Center Line Of Unit FIG. 2 Dimensions Are Nominal Roof Opening Keep This Area Free Of Obstructions Center Line Of Unit Front 18″ 12-7/8″ 29-5/8″ 27-5/8″ Model B57915 B57935 B59186 B59196 B59516 B59530 B59536 FIG. 3 Dimensions Are Nominal Keep This Area Free Of Obstructions Front Center Line Of Unit Roof Opening 18″ 13″ 39-5/8″ 29-7/8″ Model 540315, 540316 541815, 541816 541915, 541916 551816, 551916

Dimensions Are Nominal

9-1/2″ 29″ 40″ Roof Opening Front Center Line Of Unit 4″ 4″ 12″ Keep These Areas Free Of Obstructions Model 640312 640315 641815 641816 641835 641915 641916 641935 651815 651816 651916 FIG. 5 Dimensions Are Nominal 10-3/8″ 29″ 40-1/2″ Keep These Areas Free Of Obstructions Roof Opening Front Center Line Of Unit 4″ 4″ 12″ Model 640312C 640315C 641815C & H 641816C & H 641835C & H 641915C 641916C 641935C 651815C & H 651816C & H 651916C b.  Maintain structural integrity. Otherwise damage to product and/or RV could occur. The roof must be designed to support 130 pounds when the RV is in motion. Normally a 200 lb. static load design will meet this requirement. c. Check inside the RV for air distribution box (hereinafter referred to as "ADB") obstruc- tions (i.e. door openings, room dividers, cur- tains, ceiling fixtures, etc.). See (FIG. 6). FIG. 6 23-1/8″ 21-1/8″ Dimensions Are Nominal 11-9/16″ 11-9/16″ 21-1/8″ 3-7/16″ 2-5/8″ 3-7/16″ 6″ 2-7/8″ Roof Opening B. Roof Preparation 1.  FIRE OR ELECTRICAL SHOCK HAZARD. Verify there are no obstacles inside RV’s roof and/or walls (wires, pipes, etc.). Shut OFF gas supply, disconnect 120 Vac power from RV and disconnect positive (+) 12 Vdc terminal from supply battery BEFORE drilling or cutting into RV. Failure to obey these warnings could result in death or serious injury. Opening Requirements - Before preparing the ceiling opening, the type of system op- tions MUST be decided upon. Read all of the following instructions before beginning the installation. 2. Carefully mark and cut the required roof opening. See "B. Roof Requirements" on page (5). 3. Using the roof opening as a guide, cut the match- ing hole in the ceiling. 4.  Maintain structural integrity. Oth- erwise damage to product and/or RV could oc- cur.  NEVER create a low spot on RV roof. Otherwise, water will pool and could cause a leak. INSTALLATION INSTRUCTIONS

The opening created must be framed to provide

adequate support and prevent air from being drawn from the roof cavity. Framing stock 3/4″or more in thickness must be used. Remember to provide an entrance hole for power supplies, thermostat communication cable, and furnace wiring (if applicable) at the front of the opening. See (FIG. 7). 3/4″ Min. Leave Access For Power Supply Wiring FIG. 7 15″ Min. At Front Of Opening Do Not Cut Roof Structure Or Rafters Good-Rafters Supported By Cross Beams Good Location Between Roof Rafters Frame Opening So It Won't Collapse When Bolting Down Unit C. Wiring Requirements 1. Route a copper, with ground, 120 Vac supply wire from the time delay fuse or circuit breaker box to the roof opening. Use a listed/certified non metallic - sheathed single strand cable. See "A. Table - Unit Data" on page (4). a. This supply wire must be located in the front portion of the roof opening. b. The power MUST be on an appropriately sized separate time delay fuse or circuit breaker. See "A. Table - Unit Data" on page (4). c. Make sure that at least 15″ of supply wire extends into the roof opening. This insures an easy connection at the junction box. d. Protect the wire where it passes into the opening with approved method. 2. Route a dedicated 12 Vdc supply wire (18-22) AWG) from the RV converter (filtered side) or battery to the roof opening. When a Comfort Control Center 2 (here- inafter referred to as CCC 2) thermostat is being installed with more than 2 zones, route a dedicated 12 Vdc supply wire (18-22 AWG) to zone 1 and zone 3 roof opening. a. This supply wire must be located in the front portion of the roof opening. b. Make sure that at least 15″ of supply wire extends into the roof opening. 3. Thermostat Communication Cable a. CCC 2 Thermostat I. Route a 4 conductor communication ca- ble from the roof opening to the thermo- stat mounting location using the shortest most direct route. Make sure that at least 15″ of the wire extends into the roof open- ing and 6″ extends from the wall at the thermostat mounting location. See "D. Choosing Thermostat Location" on page (9). When more than one unit is being installed (additional zones) with the CCC 2 thermostat, an additional 4 conductor communication cable MUST be routed to each additional unit roof opening. Make sure that at least 15″ of the wire extends into the roof opening. See (FIG. 46). b. LCD SZ Thermostat I. Route a 3 conductor communication ca- ble, 18 to 22 AWG, from the roof open- ing to the Liquid Crystal Display Single Zone (hereinafter referred to a LCD SZ) thermostat mounting location. Make sure that at least 15″ of the wire extends into the roof opening and 6″ extends from the wall at the thermostat mounting location. See "D. Choosing Thermostat Location" on page (9). 4. (CCC 2 system only) Optional Indoor Tempera- ture Sensor a. Route an indoor temperature sensor (option- al) from the roof opening to the indoor tem- perature sensor location. The 2 pin connec- tor end goes to the roof opening. See indoor temperature sensor installation instructions for proper sensor location. 5. If system includes a gas furnace, route two 18 gauge thermostat wires from the furnace to the roof opening of the unit that will control it. If more than one furnace is to be used, route the second set of thermostat wires to the second unit. Make sure that at least 15″ of wire extends into the opening. INSTALLATION INSTRUCTIONS

Flat Four Conductor

Communication Cable b. Route the communication cable through the 2" diameter hole in the wall required for the thermostat. See (FIG. 10). FIG. 10 CCC 2 Thermostat (Rear View) Wall c. Optional Indoor Temperature Sensor I. Refer to the instructions provided with the indoor temperature sensor for details of installation. 6. (CCC 2 system only) If an Energy Management System (load shed feature) is to be used with the control, two wires must be routed to the roof opening of the zone to be managed. The signal required for this function is normally an open relay contact. When the EMS calls for the compressor to shut off, the relay contacts should close. Make sure that at least 15″ of the EMS wire extends into the roof opening. 7. (CCC 2 system only) If an Automatic Generator Start (AGS) kit will be installed, an additional 4 conductor communication cable must be routed from the last unit to the location of the AGS kit. Follow AGS kit instructions for installation. D. Choosing Thermostat Location 1. CCC 2 system without an optional indoor tem- perature sensor and LCD SZ system a. The proper location of the thermostat is very important to ensure that it will provide a com- fortable RV temperature. Observe the follow- ing rules when selecting a location. ● ●Locate the thermostat 54″ above the floor. ● ●Install the thermostat on a partition, not on an outside wall. ● ●NEVER expose the thermostat to direct heat from lamps, sun or other heat pro- ducing items. ● ●Avoid locations close to doors that lead outside, windows, or adjoining outside walls. ● ●Avoid locations close to supply registers and the air from them. 2. CCC 2 system with an optional indoor tempera- ture sensor in ALL zones a. The thermostat may be mounted anywhere that is convenient in the RV. Try to avoid hard to reach and hard to see areas. I. Refer to the instructions provided with the indoor temperature sensor for details of installation. E. Thermostat, Optional Indoor Temperature Sensor & Thermostat Communication Cable Installation 1. CCC 2 System a. The previously run communication cable (4 conductor telephone cable) must be termi- nated with two (2) RJ-11-6C4P telephone connectors. Refer to the crimp tool manufac- turer for crimping instructions. See (FIG. 8) & (FIG. 9). RJ-11-6C4P connectors MUST be in- stalled as shown in (FIG. 8) & (FIG. 9). INSTALLATION INSTRUCTIONS

d. Thermostat Installation

I. Carefully separate the thermostat base plate from the thermostat cover. Insert a small screw driver into the slot on bottom of thermostat and disengage the tab. See (FIG. 11). FIG. 11 Disengage Tab CCC 2 Thermostat II. Insert the 4 conductor communication ca- ble through the hole in base plate. Align thermostat base plate with hole in wall. Make sure base plate is level and attach base plate to wall using the four (4) sup- plied screws. III. Insert the 4 conductor communication cable connector (RJ-11-6C4P) into the connector on the back of the thermostat. See (FIG. 12). FIG. 12 4 Conductor Communication Cable IV. Align the thermostat with the back plate and snap into position. 2. LCD SZ System Wire colors listed for the communication cable (3 conductor cable) match the wire colors in the unit wire harness and the wire harness at the LCD SZ electronic control box. Available wire colors may vary. a. Remove the cover from the LCD SZ thermo- stat. Depress tab on bottom of thermostat and separate it from the base. b. Insert the previously run communication ca- ble (3 conductor cable) through the hole in the base assembly. c. Cut back the outer cable shield approxi- mately 3 inches and strip 1/4″ insulation from each wire. d. Mount the thermostat level on the wall using the screws provided. e. Make the following connections to the ther- mostat. See (FIG. 13). FIG. 13 12V- COMMS 12V+ ● ●Red/white wire to the 12V+ terminal ● ●Black wire to the 12V– terminal ● ●Orange wire to the "COMMS" terminal f. Inspect all connections to make sure they are tight and not touching any other termi- nals or wires. g. Push the wires back through the base into the wall. Place cover on the thermostat and push until an audible click is heard. F. Placing Unit On Roof 1. Remove the unit from the carton and discard carton. 2.  LIFTING HAZARD. Use proper lifting technique and control when lifting product. Failure to obey this caution could result in injury. Place unit on the roof. 3.  Do NOT slide unit. Otherwise, damage to gasket (on bottom of unit) may occur, and could cause a leak. Lift and place the unit over the prepared open- ing using the gasket on the unit as a guide. See (FIG. 14).

Do Not Slide

Lift And Place Front 4. Place the electronic control box kit (if applicable) and the ADB kit inside the RV. These boxes con- tain mounting hardware for the unit and will be used inside the RV. This completes the outside work. Minor adjustments can be done from inside the RV if required. G. Installation Preparation 1. Check gasket alignment of the unit over the roof opening and adjust if necessary. Unit may be moved from below by slightly lifting. See (FIG. 15). FIG. 15 Center Unit From Below Roof Gasket 2. Remove ADB and mounting hardware from car- ton. See (FIG. 16). FIG. 16 Duct Divider Ceiling Template ADB 3. All models in this manual will use a four (4) bolt pattern for installing the ADB kit. H. 120 Vac Power Supply Connection For models 541815A, 541816A, 541915A, 541916A, 551816A, 551916A, 641815H, 641816H, 641835H, 651815H, and 651816H go to section "I". 1.  ELECTRICAL SHOCK HAZARD. Verify 120 Vac power is disconnected from RV. Failure to obey this warning could result in death or serious injury. 2.  ELECTRICAL SHOCK HAZARD. Provide grounding in compliance with all appli- cable electrical codes. Failure to obey this warn- ing could result in death or serious injury. 3. Reach up into the return air opening of the unit and pull down the unit electrical cord and power supply wires. See (FIG. 17) & (FIG. 18). INSTALLATION INSTRUCTIONS

Models Using Electronic

Control Kit a. For units with board built in, mount the junc- tion box with screws to framing in front of roof opening and install strain relief. See (FIG. 18). b. For units with plastic electronic control box, remove junction box cover. Save screws for reinstallation. FIG. 18 Electrical Cord AC Power Supply Low Voltage Wires Models With Board Built In 4. Route the previously run 120 Vac supply wire through the strain relief and into junction box. Tighten strain relief making sure not to damage wires. Leave enough wire inside junction box to connect to unit 120 Vac wires. 5. Connect white to white; black to black; and green to green or bare copper wire using appropriate size wire connectors. 6. Tape the connectors to the supply wire to ensure they don't vibrate loose. 7. Install junction box cover on all systems except CCC 2 electronic control box. Push the wires into the junction box and install junction box cov- er using screw(s) provided. The cover for CCC 2 electronic control box will be installed later. 8. If the system has an electronic control box, plug the 6 pin electrical cord from the unit into the mating connector in the electronic control box. The plug is polarized and will only fit in one di- rection. I. 120 Vac Power Supply Connection For 541X1XA, 551X16A, 6418XXH, & 65181XH Models. 1.  ELECTRICAL SHOCK HAZARD. Verify 120 Vac power is disconnected from RV. Failure to obey this warning could result in death or serious injury. 2.  ELECTRICAL SHOCK HAZARD. Provide grounding in compliance with all appli- cable electrical codes. Failure to obey this warn- ing could result in death or serious injury. 3. Reach up into the return air opening of the unit and pull down the unit electrical cord and power supply wires. See (FIG. 19). FIG. 19 Low Voltage Wires AC Power Supply Electrical Cord 4. Carefully strip and prepare 120 Vac supply wire. See (FIG. 20), (FIG. 21), (FIG. 22), (FIG. 23), & (FIG. 24). INSTALLATION INSTRUCTIONS

Strip Jacket To 1″

FIG. 21 Hand Bend White And Black Wires Outward 90° FIG. 22 Use Tip Of Pliers To Hold Wire In Place While Hand Bending Wire At 90° FIG. 23 Repeat With Other Wire FIG. 24 Trim Ground Wire To Length Of Outer Wires 5. Hold the clear strain relief cover with the bottom facing upward. See (FIG. 25). FIG. 25 Load Cable into Strain Relief Wire Locator Slots Position Black Wire Into Locator Slot Strain Relief Cover (Bottom Facing Upward) Strain Relief Fingers Roll Cable Sheath Into Integral Strain Relief 6. Lay wire into locator slots, making sure the black wire is placed into the polarization slot. See (FIG. 25). 7. Press the cable sheath into the integral strain relief slot. See (FIG.  25). Trimming of ground wire and possibly others will be necessary. Wires must not extend beyond the locators. See (FIG. 26). FIG. 26 Housing Assembly Hinge Slots Strain Relief Cover Wires Trimmed And Correctly Located In Locator Stops Hinge Posts 8. While holding the strain relief cover, position the housing's hinge posts into the hinge slots and press down until both lock into place. See (FIG. 26). 9. Close the strain relief cover and housing by hand. Squeeze the top and bottom closed with tongue and groove pliers. See (FIG. 27). Pliers must be a minimum of 10″ long. Squeeze firmly on both sides, squarely across the connector between ribs A and B to ensure wires seat com- pletely into slots. INSTALLATION INSTRUCTIONS

Attaching Housing Assembly To Strain

Relief Cover With Tongue And Groove Pliers, Squeeze Squarely & firmly Between Ribs A & B Strain Relief Cover 10″ Minimum Rib A Locking Ramp Locking Latch Rib B Housing Assembly 10. Inspect the connector to ensure the wires have been properly engaged into the housing assem- bly contacts. A properly terminated wire is fully seated into its proper slots with no significant bow of the cover. If the wires extend past the insulation stops the wires must be re-terminated with a NEW CONNECTOR. Once the cover has been closed the connector cannot be re-used. Failure to comply with this procedure may result in the failure of the connector. 11. Mating and un-mating the completed connector is illustrated below. See (FIG. 28). FIG. 28 Housing Assembly Strain Relief Cover Depress Mating Latch To Disconnect To release the connector system, depress both mating latches at the same time and pull the connectors apart. To reconnect, simply re-mate the connectors and slide them together until mating latches lock. Strain Relief Cover Depress Mating Latch To Disconnect Housing Assembly "Hermaphroditic" Part Mates With Itself J. Duct Divider Installation 1. Measure the ceiling thickness. See (FIG. 17). 2. Cut away the number of rows as indicated in table below. See (FIG. 29). Ceiling Thickness # Of Rows To Cut Ceiling Thickness # Of Rows To Cut Min. Max. Min Max. 6.0 6.5 0 3.5 4.0 5 5.5 6.0 1 3.0 3.5 6 5.0 5.5 2 2.5 3.0 7 4.5 5.0 3 2.0 2.5 8 4.0 4.5 4 1.5 2.0 9 FIG. 29 Remove Rows Starting Here 3. Carefully install the duct divider in the roof opening 5-5/8″ from back of roof opening. See (FIG. 30). Foil back faces rear of unit. FIG. 30 Rear Base Pan 5-5/8″ From Back Of Roof Opening Duct Divider Front Black Side To Front K. LCD SZ System Low Voltage Wire Connections  Verify the positive (+) 12 Vdc termi- nal is disconnected from supply battery. Otherwise, damage to unit could occur. 1. Plastic Case Electronic Control Kit Systems Only a. Plug the supplied freeze control sensor and the 4 wire harness into their matching con- nectors in the electronic control box. INSTALLATION INSTRUCTIONS

CCC 2 System Low Voltage Wire

Connections  Verify the positive (+) 12 Vdc termi- nal is disconnected from supply battery. Otherwise, damage to unit could occur. 1. CCC 2 Electronic Control Kit Systems a. Plug the 6 wire harness into the matching 6 pin connector in the electronic control box. b. Plug the freeze control sensor into the P5 (Blue or Black) 2 pin matching connector in the electronic control box. c. Insert the freeze control sensor into the evaporator coil fins approximately 1″ above the bottom of the coil fins and on the left side. See (FIG. 31). Bend fins over sensor to secure in place. 2. All Heat Pump Electronic Control Kit Systems a. Plug the outdoor temperature sensor from the unit into the P3 (white) 2 pin matching connector in the electronic control box. b. Plug the 3 pin connector (reversing valve wire) from the unit into the 3 pin matching connector in the electronic control box. 3. All CCC 2 Systems a. Connect the previously run 12 Vdc supply wires to the red and black wires protruding from the roof opening or the red and black wires in the 6 wire harness at the electron- ic control box. Connect +12 Vdc to the red wire; –12 Vdc to the black wire. b. Connect the previously run furnace thermo- stat wires (if applicable) to the blue wires protruding from the roof opening or the blue wires in the 6 wire harness at the electronic control box. The polarity of this connection does not matter. c. Terminate the 4 conductor communication cable(s) protruding from the roof opening. The cable(s) must be terminated with a tele- phone RJ-11-6C4P connector. Refer to the crimp tool manufacturer for crimping instruc- tions. RJ-11-6C4P connectors MUST be in- stalled as shown in (FIG. 8) & (FIG. 9). d. Plug the 4 conductor communication cable into one of the couplers protruding from the roof opening or in the electronic control box. If more than one zone is used, the second coupler is used to join each addition zone. 2. All Heat Pump Electronic Control Kit Systems a. Plug the outdoor temperature sensor from the unit into the white 2 pin matching con- nector in the electronic control box. 3. All LCD SZ Electronic Control Kit Systems a. Insert the freeze control sensor into the evaporator coil fins approximately 1″ above the bottom of the coil fins and on the left side. See (FIG. 31). Bend fins over sensor to se- cure in place. FIG. 31 Route Up Through Return Air Opening Remove Hang Tag Freeze Control Sensor 4. All LCD SZ Systems a. Connect the previously run +12 Vdc supply wire to the red wire protruding from the roof opening or to the red wire at the electronic control box. b. Connect the previously run –12 Vdc supply wire to both the black wire protruding from the roof opening or to the black wire at the electronic control box and to the wire of the three wire cable that goes to the thermostat 12V– terminal. c. Connect the previously run furnace thermo- stat wires (if applicable) to the blue wires protruding from the roof opening or to the 1/4″ connectors at the electronic control box using the supplied 1/4″ insulated connectors. The polarity of this connection does not ma- ter. d. Connect the red/white wire protruding from the roof opening or the red/white wire at the electronic control box to the wire of the three wire cable that goes to the thermostat 12V+ terminal. e. Connect the orange wire protruding from the roof opening or the orange wire at the elec- tronic control box to the wire of the three wire cable that goes to the thermostat COMMS terminal. INSTALLATION INSTRUCTIONS

Dip switches are in the "OFF" position

when shipped from the factory except heat pump and factory installed heat strip models. On these models the appropriate dip switch, heat pump or heat strip, is in the "ON" position from the factory. To gain access to the dip switches on mod- els with board built in, the out side plastic shroud MUST be removed from the unit. Next remove the electrical box cover. The electrical box will be on the curb side of the RV after installation. See (FIG. 32). Installations using the electronic control box the dip switches are visible through the opening in the electronic control box. See (FIG. 33). FIG. 34 Dip Switches Zone 2 Ext. Stage Zone 3 Zone 4 Stage Heat Strip Heat Pump Furnace Dehumidify Gen Start a. Ext. Stage - Ext. Stage is not used on this unit. Leave in the "OFF" position. b. Zone selection - Each CCC 2 thermostat can have up to 4 zones. When only one unit is in- stalled it becomes Zone 1 and no dip switch setting is required. Each additional unit must be assigned a zone (2 through 4). Each unit must have a different zone setting. c. Stage selection - Stage is not used on this unit. Leave in the "OFF" position. d. Heat Strip - On heat strip models the #6 dip switch is in the "ON" position from the factory. Non heat strip models leave in the "OFF" position. e. Heat Pump - On heat pump models the #7 dip switch is in the "ON" position from the factory. Non heat pump models leave in the "OFF" position. f. Furnace - If a Furnace/Aqua heat system has been connected to this unit, the fur- nace dip switch must be placed in the "ON" position. e. Plug the indoor temperature sensor cable (if applicable) into the 2 pin matching connec- tor protruding from the roof opening or the P4 (white) 2 pin matching connector in the electronic control box. f. Connect the previously run Energy Manage- ment System wires (if applicable) to the yel- low wires protruding from the roof opening or the yellow wires in the 6 wire harness at the electronic control box. The polarity of this connection does not matter. g. If an automatic generator start (AGS) kit is installed, follow installation instructions fur- nish with AGS kit. M. (CCC 2 System Only) Configuration 1. Electronic Control Configuration Depending on the equipment options installed by the recreational vehicle manufacturer, the ap- propriate dip switches will need to be switched to the "ON" position. Placing the switch in the "ON" position selects that option. See (FIG. 32), (FIG. 33), (FIG. 34), & (FIG. 35). FIG. 32 Models With Board Built In Dip Switches FIG. 33 Dip Switches Models With Electronic Control Box INSTALLATION INSTRUCTIONS

g. Dehumidify - Dehumidify is not used on this

unit. Leave in the "OFF" position. h. Gen Start selection - Leave in the "OFF" position. i. Install unit electrical box cover and out side plastic shroud or the electronic control box cover whichever applies. j. Repeat this procedure for each additional zone. FIG. 35 On Position Off Position N. Installing Unit 1. If system includes an electronic control box in- stall it at this time. Make sure all wiring has been completed and that the electronic control box cover has been installed. To secure electronic control box to ceiling template drive two (2) #6 x 3/8″ (plastic control box) or two (2) #10 x 3/8″ (metal control box) blunt point Phillips head screws (provided) through the ceiling template and into holes in the electronic control box. See (FIG. 36). FIG. 36 Blunt Point Screw Ceiling Template Electronic Control Box Metal Electronic Control Box Shown 2. If your installation includes the optional electric heat kit, install it at this time. Follow the instruc- tions with heat kit package for its installation pro- cedure. 3. Ceiling Template Installation a. Hold the ceiling template up to the roof open- ing and line up the channel in the ceiling template with the previously installed duct divider. See (FIG. 37). FIG. 37 Duct Divider Channel Model With Electronic Control Box Shown b. Hold the ceiling template up to the roof open- ing and start each mounting bolt by hand, through the ceiling template and up into the unit base pan. See (FIG. 38) & (FIG. 39). FIG. 38 Mounting Bolt Mounting Bolt

Mounting Bolt Pattern Table

See (FIG. 39) Model Bolt Location 457915 A, D, E & H B57915 A, D, E & H B57935 A, D, E &H 459186 A, D, E & H B59186 A, D, E & H 459196 A, D, E & H B59196 A, D, E & H 459516 A, D, E & H B59516 A, D, E & H 459530 A, D, E & H B59530 A, D, E & H B59536 A, D, E & H 540315 B, C, F & G 540316 B, C, F & G 541815 B, C, F & G 541816 B, C, F & G Mounting Bolt Pattern Table See (FIG. 39) Model Bolt Location 541915 B, C, F & G 541916 B, C, F & G 551816 B, C, F & G 551916 B, C, F & G 640312 B, C, F & G 640315 B, C, F & G 641815 B, C, F & G 641816 B, C, F & G 641835 B, C, F & G 641915 B, C, F & G 641916 B, C, F & G 641935 B, C, F & G 651815 B, C, F & G 651816 B, C, F & G 651916 B, C, F & G FIG. 39 A H G F E D C B c.  Tighten mounting bolts to correct torque specifications. Overtighten- ing could damage unit’s base pan or ceiling template. Not enough torque will allow an in- adequate roof seal, and could cause a leak. d. Tighten all four (4) mounting bolts EVENLY with in 40 to 50 inch pounds. See (FIG. 38). O. Installing ADB 1. Align ADB with ceiling template. See (FIG. 40) & (FIG. 41). Front and rear vent doors are supplied loose. Do NOT install them until all screws are installed in step 2 & 3. INSTALLATION INSTRUCTIONS FIG. 40 ADB Alignment Holes Ceiling Template Alignment Holes FIG. 41 ADB Hole Alignment Hole In Ceiling Template Hole In ADB Cover 2. Install two (2) (supplied) sheet metal screws in- side return air opening to secure ADB to ceiling template. See (FIG. 42).

3. Install eight (8) (supplied) wood screws inside

the front, rear, and side doors to secure ADB to ceiling. See (FIG. 42). FIG. 42 2 Sheet Metal Screws 8 Wood Screws 4. Install front and rear doors. 5. Place filter into return air vent grille. It may al- ready be installed on some units. See (FIG. 43). FIG. 43 Filter Return Air Vent Grille 6. Install return air vent grille into the ADB. Slide re- turn air vent grille tab into slot in ADB and rotate up and snap in place. See (FIG. 44). FIG. 44 Slot In ADB Return Air Grille This completes the LCD SZ system installa- tion. (Proceed to section "P" to complete the CCC 2 system installation). 7. (LCD SZ System Only) System Checkout a. Verify that all features of the system work. See the LCD SZ thermostat Operating In- structions or User's Guide. Reconnect the 12 Vdc and 120 Vac power supplies. Check fan speeds, cooling mode, heating mode, and furnace mode (if connected) operation. If features do not work, disconnect the 120 Vac and 12 Vdc power supplies and verify that all wiring is correct. P. (CCC 2 System Only) Reset & Checkout 1. System Reset After setting the dip switches in the electronic control, do a system reset. a. Reconnect the 12 Vdc and 120 Vac power supplies. b. Make sure the CCC 2 thermostat is in the OFF mode. c. Simultaneously press the MODE and ZONE buttons. The LCD will display "IniT" and all available zones. d. Release the MODE and ZONE buttons. e. Press the ON/OFF button to exit system setup. f. When a dip switch is turned on after initial configuration, a system reset will need to be done before the CCC 2 thermostat will rec- ognize the updated selection. 2. System Checkout a. Verify that all features of the system work. See CCC 2 thermostat Operating Instruc- tions or User's Guide. Check fan speeds, cooling mode, heating mode, and furnace mode (if connected) operation. If features do not work, disconnect the 120 Vac and 12 Vdc power supplies and verify that all wiring is correct.

(CCC 2 System Only) Furnace/Aqua

Temperature Differential Setting This system can be configured to operate using an ON//OFF differential of either 1 degree F or 2 de- gree F See (FIG. 45). 1. To set the differential, simultaneously press the PROGRAM button and the up button on the CCC 2 thermostat. “diF1” will appear in the display while the buttons are pressed. See (FIG. 45). To set the 2 degree differential, simul- taneously press the PROGRAM button and the down button. “diF2” will appear in the display while the buttons are pressed. FIG. 45 GENERAL INFORMATION A. Heat Gain The ability of this air conditioner to maintain the desired inside temperature depends on the heat gain of the RV. Some preventative measures taken by the occupants of the RV can reduce the heat gain and improve the performance of the air conditioner. During extremely high outdoor tem- peratures, the heat gain of the vehicle may be reduced by: 1. Parking the RV in a shaded area 2. Using window shades (blinds and/or curtains) 3. Keeping windows and doors shut or minimizing usage 4. Avoiding the use of heat producing appliances Operation on High Fan/Cooling mode will give optimum or maximum efficiency in high humidity or high outside temperatures. Starting the air conditioner early in the morning and giving it a “head start” on the expected high outdoor ambient will greatly improve its ability to maintain the desired indoor temperature. For a more permanent solution to high heat gain, acces- sories like Dometic outdoor patio and window awnings will reduce heat gain by removing the direct sun. They also add a nice area to enjoy company during the cool of the evening. B. Condensation The manufacturer of this unit will not be responsible for damage caused by condensation forming on ceilings, windows, or other surfaces. Air contains water vapor which condenses when temperature of a surface is below Dew point. During normal operation this unit is designed to remove a certain amount of moisture from the air, depend- ing on the size of the space being conditioned. Keeping doors and windows closed when this air conditioner is in operation will greatly reduce the chance of condensation forming on interior surfaces. If your unit fails to operate or operates improperly, check the following before calling your service center.

2. 459186 & B59186 Unit Wiring Diagram

FIG. 48 WIRING DIAGRAMS A. Simple RV Wiring Diagram (OPTIONAL) FIG. 46 B. Unit Wiring Diagrams 1. 457915, B57915, B57935, 459516, B59516, 459530, B59530 & B59536 Unit Wiring Dia- gram FIG. 47

6. 551816, 651815, & 651816 Unit Wiring Dia-

gram FIG. 52 7. 551916 Unit Wiring Diagram 5(9(56,1*9$/9( %/.  37&5 237 %5 :+7 :+7 %5 67$57 &$3 5(' :+7 %/8 5(' 2/ & 5 6

12. 651916 Unit Wiring Diagram

5(9(56,1*9$/9( %/.  37&5 237 %5 :+7 :+7 %5 67$57 &$3 5(' :+7 %/8 5(' 2/ & 5 6

3. 3313189.049 & 3313189.056 LCD SZ Elec-

tronic Control Kit Wiring Diagram Cool/Fur- nace/HS 96833/< 96833/<   < )$1+, < %/. 6(5,$/1R &211(&7,21 +($7675,3 :+7 *5< 1$    &20 12  )25$&:,7+237,21$/+($7675,3 21/< &21'8&7256 +=2 86(&233(5 9$& )5((=( 6(1625 &200767$7 )851$&( )851$&( 9767$7 &211(&7,21 $& 25* 5(':+7 %/:7 %/:7 %/. 5(' :+7   *51<(/ - < -     12 &20 5(' 1&   %/8   %/. < )$1/2 ),(/':,5,1* )$&725<:,5,1* ',(/(&75,& 3$66('  9$&+]2 /$*5$1*(,1 6323/$567 )2586(:,7+$,5&21',7,21(5 3$571R 9767$7 FIG. 61 4. 3313189.064 & 3313189.072 LCD SZ Elec- tronic Control Kit Wiring Diagram Cool/Fur- nace/HP 9$& 5(9(56,1*9$/9( (1(5*,=('72+($7 %/. ),(/':,5,1* )$&725<:,5,1* )851$&( )851$&( 9 5(':+7 5(' %/. 25* &200 9     < < %/8 %/8 9 21/< &21'8&7256 +=2 86(&233(5 *5< *5< - )5((=(6(1625 6(1625 287'2257(03 - .5(/$< < 5(' %/. %/8 < < < &20 12 )520$& (/(&&211 :+7  *51<(/ 5('   %/8   %/.  ,)7+,6352'8&7,66833/,('%<$:,5,1*6<67(07+$7,1$&&25'$1&(:,7+ &$1$',$1(/(&75,&&2'(3$57&$1'7+(1$7,21$/(/(&75,&&2'( $16,1)3$125(48,5(67+(,167$//$7,212)$1(48,30(17*5281',1* &21'8&72525&21'8&72567(50,1$/ 6 25*5281'6&5(: 6 )257+,6  - 72 767$7 ` ` 9 6833/<  385326(0867%(,167$//(' FIG. 62