Ellington E-VER54ABZ5LKRW Installation Manual
Read Online
Read the Ellington E-VER54ABZ5LKRW Installation Manual online using the built-in PDF viewer.
Text of the manual
Table of Contents:
Safety Tips. pg. 1
Unpacking Your Fan. pg. 2
Parts Inventory. pg. 2
Installation Preparation. pg. 3
Hanging Bracket Installation. pg. 3
Fan Assembly. pgs. 4 - 5
Wiring. pgs. 5 - 6
Canopy Assembly. pg. 6
Blade Assembly. pg. 7
Light Kit Assembly. pg. 7
Wall Control Operation. pg. 8
Remote Control Operation. pg. 8
Testing Your Fan. pg. 8
Troubleshooting. pg. 9
Warranty. pg. 9
Parts Replacement. pg. 9
Installation Guide
For Models:
E-VER54ABZ5LKRW
E-VER54BNK5LKRW
net weight of fan: 20.28 lb. (9.2 kg)
PRINTED IN CHINA
READ THESE INSTRUCTIONS
AND SAVE THEM FOR FUTURE USE
Federal regulations require ceiling fans
with light kits manufactured or imported
after January 1, 2009, to limit total
wattage consumed by the light kit to
190W. Therefore, this fan is equipped
with a wattage limiting device.
E206035
WARNING: To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit
panel before you begin the fan installation or before servicing the fan or installing accessories.
1. READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN
AND SAVE THESE INSTRUCTIONS.
CAUTION: To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp
edges.
2. Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code,
and ANSI/NFPA 70-1999. If you are unfamiliar with electrical wiring or if the house/building wires are
different colors than those referred to in the instructions, please use a qualified electrician.
3. Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at
least seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips. The fan should
be mounted so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or
other upright structures.
4. The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at
least 35 pounds (16 kilograms). The outlet box must be supported directly by the building structure.
Use only UL listed outlet boxes marked "FOR FAN SUPPORT."
WARNING: To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked
"Acceptable for Fan Support of 15.9 kg (35 lbs.) or less," and use the mounting screws provided with the outlet
box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified electrician if in doubt.
WARNING: To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan
are designed to accept only one 12 gauge house wire and two lead wires from the fan. If your house wire is
larger than 12 gauge or there is more than one house wire to connect to the two fan lead wires, consult an
electrician for the proper size wire connectors to use.
5. Electrical diagrams are for reference only. Light kits that are not packed with the fan must be UL listed and
marked suitable for use with the model fan you are installing. Switches must be UL general use
switches. Refer to the instructions packaged with the light kits and switches for proper assembly.
6. After installation is complete, check that all connections are absolutely secure.
7. After making electrical connections, spliced conductors should be turned upward and pushed carefully up
into the outlet box. The wires should be spread apart with the grounded conductor and the
equipment-grounding conductor on opposite sides of the outlet box.
WARNING: To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control
device or control fan speed with a full range dimmer switch. [Using a full range dimmer switch to control fan
speed will cause a loud humming noise from fan.]
8. Do not operate the fan in reverse until fan has come to a complete stop. [Note: If using remote
control with reverse capability, reverse fan blade direction only when on LOW speed.]
9. Do not insert anything between the fan blades while they are rotating.
WARNING: To reduce the risk of personal injury, do not bend the blade arms during assembly or after
installation. Do not insert objects into the path of the blades.
WARNING: To avoid personal injury or damage to the fan and other items, be cautious when working around or
cleaning the fan.
10. Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened
cloth will be suitable for most cleaning.
WARNING: To reduce the risk of personal injury, use only parts provided with this fan. The use of parts OTHER
than those provided with this fan will void the warranty.
NOTE: The important safety precautions and instructions appearing in the manual are not meant to cover all
possible conditions and situations that may occur. It must be understood that common sense and caution are
necessary factors in the installation and operation of this fan.
2. Parts Inventory.
a. hanging bracket (pre-attached to canopy).
1 piece
b. remote control transmitter. 1 piece
c. remote control receiver. 1 piece
d. wall control. 1 piece
e. yoke cover. 1 piece
f. canopy. 1 piece
g. 8in. downrod and hanging ball
(with pin & clip). 1 piece
h. motor assembly. 1 piece
i. safety cable with vice (already attached to
motor). 1 piece
j. blade arm. 5 pieces
k. blade. 5 pieces
l. blade plate. 5 pieces
m. glass shade. 1 piece
n. light kit fitter. 1 piece
o. hardware packs
page 2
d
l
n
m
k
e
f
a
b
c
1. Unpacking Your Fan.
Carefully open the packaging. Remove items
from Styrofoam inserts. Remove motor housing
and place on carpet or Styrofoam to avoid
damage to finish. Do not discard fan carton or
Styrofoam inserts should this fan need to be
returned for repairs.
Check against parts inventory that all parts have
been included.
g
h
j
o
i
IMPORTANT REMINDER: You must
use the parts provided with this fan for
proper installation and safety.
w/ remote
control
w/ wall
control
bulbs required:
3 x 13 watt max. compact fluorescent bulbs,
size GU24 (included)
3. Installation Preparation.
To prevent personal injury and damage, ensure
that the hanging location allows the blades a
clearance of 7ft. (2.13m) from the floor and 30in.
(76cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
This fan can be mounted with a downrod
on a normal or vaulted ceiling. The hanging
length can be extended by purchasing a longer
downrod (0.5in./1.27cm diameter). Other
installation, such as flushmount, is not available
for this fan.
Installation requires these tools:
Phillips screwdriver, flathead screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
page 3
Vaulted ceiling
angle is not to
exceed 25 degrees.
downrod
installation
flushmount
installation
12ft. - 20ft.
12ft. - 20ft.
(3.66m - 6.1m)
(3.66m - 6.1m)
blade edge
7 feet
(2.13m)
(76cm)
30
inches
4. Hanging Bracket Installation.
Turn off circuit breakers to current fixture from breaker
panel and be sure operating light switch is turned to the
OFF position.
WARNING: Failure to disconnect power supply prior to
installation may result in serious injury.
Remove existing fixture.
WARNING: When using an existing outlet box, be sure the
outlet box is securely attached to the building structure and
can support the full weight of the fan. Ensure the outlet box is
clearly marked "Suitable for Fan Support." If not, it must be
replaced with an approved outlet box. Failure to do so can
result in serious injury.
CAUTION: Be sure outlet box is grounded and that a ground
wire (green or bare) is present.
Partially loosen screws in slotted holes of canopy. Remove
the other 2 screws--save for later use. Twist canopy to
remove hanging bracket.
Install hanging bracket to outlet box using original screws,
spring washers and flat washers provided with new or
original outlet box.* If installing on a vaulted ceiling, face
opening of hanging bracket towards high point of ceiling.
Arrange electrical wiring around the back of the hanging
bracket and away from the bracket opening.
*Note: It is very important that you use the proper hardware
when installing the hanging bracket as this will support the
fan.
ON
OFF
ON
OFF
hanging bracket
spring washers
outlet box screws
flat washers
5. Fan Assembly.
page 4
If you wish to extend the hanging length of your
fan, you must remove the hanging ball from the
8in. downrod provided to use with an extended
downrod (sold separately). [If you wish to use the
8in. downrod, please proceed to instructions
following the dotted line below.]
To remove hanging ball, loosen set screw on
hanging ball and remove the pin and clip. Lower
hanging ball and remove stop pin. Slide hanging
ball off the original downrod, A, and slide it down
the longer downrod, B (the top of the downrod
should be noted as having a set screw hole; use
this hole when setting the set screw). Insert stop
pin into top of extended downrod and raise
hanging ball. Be sure stop pin aligns with slots on
the inside of the hanging ball. Tighten set screw
securely. [Refer to diagram 1.]
Remove vice from safety cable by loosening the
screw and nut on the vice. [Refer to diagram 2.]
Tip: To prepare for threading electrical wires
through downrod, apply a small piece of electrical
tape to the ends of the electrical wires--this will
keep the wires together when threading them
through the downrod.
Loosen yoke set screws and nuts at top of motor
housing. Remove pin and clip from downrod (if
you have not already done so). Slide downrod
through canopy and yoke cover.
Thread safety cable and electrical wires through
downrod and pull extra wire slack from the upper
end of the downrod. [Refer to diagram 3.]
Place downrod into the motor housing yoke and
re-insert pin and clip that were previously
removed. Tighten yoke set screws and nuts
securely. [Refer to diagram 3.] Lower yoke cover to
motor housing.
["Fan Assembly" continued on next page.]
NOTE: The important safety precautions and
instructions appearing in the manual are not meant to
cover all possible conditions and situations that may
occur. It must be understood that common sense and
caution are necessary factors in the installation and
operation of this fan.
safety cable
downrod
electrical wiring
pin
clip
canopy
motor housing
yoke set screw
and nut
yoke cover
safety cable vice
diagram 2
nut
screw
diagram 1
pin
clip
set screw hole
set screw
hanging ball
stop pin
A
B
diagram 3
5. Fan Assembly. (cont.)
wood
ceiling
joist
hanging ball slot
hanging bracket tab
motor housing
canopy
6. Wiring.
code
switches
wall control
1
2 3 4
9-volt battery
remote
control
transmitter
battery cover
code switches
1
1
Use a ballpoint pen or a small screwdriver to set
the code switches for the wall control, remote
control transmitter and remote control receiver so
that they match. Factory setting is pre-set and not
recommended for use. If your wall/remote control
interferes with other appliances, change to
another matching code on the wall/remote
control transmitter and receiver.
Note: Remove the small cover from remote
control receiver in order to access the code
switches as shown in diagram to the right.
In order for the remote control to operate, one
9-volt battery (sold separately) should be installed
in the remote control. Re-attach the battery cover
after installing the battery.
["Wiring" instructions continued on next page.]
1
2 3 4
remote
control
receiver
small
cover
safety cable loop
safety cable
wood screw
and washer
nut
screw
With the hanging bracket secured to the outlet box
and able to support the fan, you are now ready to
hang your fan. Grab the fan firmly with two hands.
Slide downrod through opening in hanging bracket
and let hanging ball rest on the hanging bracket.
Turn the hanging ball slot until it lines up with the
hanging bracket tab.
Tip: Seek the help of another person to hold the
stepladder in place and to help lift the fan up to you
once you are set on the ladder.
Replace vice on safety cable and adjust safety cable
length by loosening screw and nut on the safety
cable vice and pulling on the cable. Adjust slack in
cable to a hands length and secure vice by
tightening screw and nut securely. [Refer to
drawing at right.] The loop at the end of the safety
cable should just fit over the threads on the wood
screw. Test safety cable by pulling on loose end with
pliers. If the safety cable slips, the screw and nut on the
vice must be set tighter.
Find a secure attachment point (wood ceiling joist
highly recommended) and secure safety cable. It
will be necessary to use a heavy duty wood screw,
washer and lock washer (not supplied) with the
safety cable loop. Extra cable slack can be left in
ceiling area.
black (OUT to fan)
green
black
(AC IN from
breaker box)
black
(TO POWER supply)
black
green/
green/
bare
bare
ground
ground
green/
bare
ground
7. Canopy Assembly.
canopy
hanging bracket
antenna
receiver
6. Wiring. (cont.)
IN ORDER TO WIRE WALL CONTROL, remove
existing wall switch. Wire the WALL CONTROL with
wire connectors provided as shown in diagram 2
at right.
* Wrap each wire connector separately with
electrical tape as an extra safety measure. Gently
push taped wire connectors into outlet box.
Attach wall control to outlet box and secure with
screws from original wall switch. Attach front plate
to wall control using 2 screws provided in the wall
control.
diagram 2
(wiring for wall control)
dip switches
wall
control
plate
outlet box
1
2 3 4
CAUTION: Be sure outlet box is properly grounded and
that a ground wire (GREEN or Bare) is present.
Make sure all electrical connections comply with Local
Codes or Ordinances and the National Electrical Code. If
you are unfamiliar with electrical wiring or if the
house/building wires are different colors than those
referred to in the diagram to the right, please use a
qualified electrician.
When downrod is secured in place on the hanging
bracket, WIRE THE RECEIVER with wire connectors
provided as shown in diagram 1 at right.
Tip: While you are wiring, keep in mind that wires must
not obstruct receiver from sliding into hanging bracket.
* Wrap each wire connector separately with electrical
tape as an extra safety measure.
Insert receiver into hanging bracket (flat side up) and
gently push taped wire connectors into outlet box.
Allow antenna from remote control receiver to hang
out of the hanging bracket.
black
black
black
from receiver
from fan
from ceiling
from receiver
white
white
blue
blue
black supply wire
ground (green
or bare)
white supply wire
white
AC IN N
AC IN L
receiver
black
white
diagram 1
(wiring for receiver)
Raise canopy to hanging bracket and align
slotted holes in canopy with loosened screws in
hanging bracket. Twist canopy to lock. Re-insert
screws (with lock washers) that were previously
removed (page 3, Section 4) and secure all
screws with Phillips screwdriver.
*Remember that antenna for remote control
receiver must rest outside of hanging bracket.
8. Blade Assembly.
page 7
9. Light Kit Assembly.
Remove 1 screw on fitter plate (on underside of
motor) and loosen the other 2 screws. Align slotted
holes in center of shade fitter with loosened screws
on fitter plate. Twist shade fitter to lock. Re-insert
screw that was just removed and tighten all 3 screws.
Install the 13 watt (max.) compact flourescent bulbs,
type GU24, provided.
Remove finial from threaded rod on glass fitter. Align
hole in glass shade with threaded rod and push up.
Secure glass shade with finial that was removed. Do
not overtighten finial as glass may crack or break.
Important: When replacing bulbs, please allow
bulbs, glass shade and finial to cool down before
touching.
blade plate
motor housing
motor housing
blade
blade arm
blade arm
blade attachment screws
lock washer and
blade arm screw
fitter screw
fitter plate
molex connections
Locate 15 blade attachment screws in one of the
hardware packs. Hold blade plate up to blade
and align holes, as shown, and lower blade arm
over blade holes. Insert 3 blade attachment
screws with fingers first and then tighten screws
securely with a Phillips screwdriver. Repeat for
the remaining blades.
Locate blade arm screws and lock washers in one
of the hardware packs. Align blade arm holes
with motor screw holes and attach blade arm
with screws and lock washers. Before securing
screws permanently, repeat this procedure with
remaining blade arms. Secure all screws.
Note: Tighten blade attachment screws and
blade arm screws twice a year.
fitter screw
finial
glass shade
bulb
shade fitter
Hg
LAMP CONTAINS MERCURY
Manage in accordance with Spills, Disposal and Site Cleanup
Requirements. In case of breakage, follow clean-up
procedures provided by contacts below.
www.epa.gov/cflcleanup
1-866-284-4010
It is recommended that you test fan before finalizing
installation. Restore power from circuit box and light
switch (if applicable). Locate ON/OFF slider switch on wall
control and set to the ON position. Test light and then
test fan speeds. Next, locate remote control. Start with
the lights OFF and test the light ON/OFF function by
pressing the button. Test fan speeds with the different
fan speed buttons. If the remote control operates all of
the functions of the fan, battery has been installed
correctly. If the wall and/or remote controls do (does) not
operate all of the fan functions, refer to "Troubleshooting"
section to solve any issues before contacting Customer
Service.
Fan must be on LOW before setting the fan to reverse
direction. Use REV button to recirculate air depending on
the season.
12. Testing Your Fan.
11. Remote Control Operation.
10. Wall Control Operation.
ON/OFF slider switch - turns wall control ON or OFF
HI button - turns fan to HIGH speed
MED button - turns fan to MEDIUM speed
LOW button - turns fan to LOW speed
FAN OFF button - turns fan OFF
REV button - used to REVERSE blade direction (fan
must be set on low before reversing blade
direction)
LIGHT button - turns light ON/OFF
HI button - turns fan to HIGH speed
MED button - turns fan to MEDIUM speed
LOW button - turns fan to LOW speed
OFF button - turns fan OFF
REV button - used to REVERSE blade direction (fan must be
turned low before reversing blade direction)
button - turns light ON/OFF
ELLINGTON LIFETIME LIMITED WARRANTY:
ELLINGTON/LITEX INDUSTRIES, LTD. warrants this fan to the
original household purchaser for indoor use under the
following provisions:
1-YEAR WARRANTY: ELLINGTON/LITEX INDUSTRIES, LTD.
will replace or repair any fan which has faulty performance
due to a defect in material or workmanship. Contact Litex
Customer Service at 1-800-527-1292 to arrange for return
of fan. Return fan, shipping prepaid, to Litex Industries, Ltd.
We will repair or ship you a replacement fan, and we will
pay the return shipping cost.
5-YEAR WARRANTY: ELLINGTON/LITEX INDUSTRIES, LTD.
will repair or replace, at no charge to the original purchaser,
any fan motor that fails to operate satisfactorily when
failure results from normal use.
RETURN FAN MOTOR ONLY, shipping prepaid, to Litex
Industries. We will repair or ship purchaser a replacement
motor and Litex will pay the return shipping cost.
6-YEAR to LIFETIME LIMITED WARRANTY: ELLINGTON/LITEX
INDUSTRIES, LTD. will repair the fan, at no charge to the
original purchaser for labor only, if the fan motor fails to
operate satisfactorily when failure results from normal use.
Parts used in the repair will be billed to the purchaser at
prevailing prices at time of repair.
The purchaser shall be responsible for all costs incurred
in the removal, reinstallation and shipping of the product
for repairs.
This warranty does not apply when damage from
mechanical, physical, electrical or water abuse results in
causing the malfunction. Deterioration of finishes or other
parts due to time or exposure to salt air is specifically
exempted under this warranty.
Neither Litex Industries nor the manufacturer will
assume any liability resulting from improper installation or
use of this product. In no case shall the company be liable
for any consequential damages for breach of this, or any
other warranty expressed or implied whatsoever. This
limitation as to consequential damages shall not apply in
states where prohibited.
Parts Replacement.
For parts and information, please refer to
"Parts Inventory" on page 2.
Ellington Customer Support:
1-800-527-1292
www.ellingtonfans.com
WARNING: Failure to disconnect power supply
prior to troubleshooting any wiring issues may
result in serious injury.
Problem: Fan fails to operate.
Solutions:
1. Check wall switch to fan.
2. Check to be sure code switches are set properly.
3. Verify that receiver is wired properly.
4. Verify that fan is wired properly.
5. Verify that wall control is wired properly.
6. Check that red light on remote control
transmitter turns on when a button is pressed
indicating that the battery is good.
Problem: Light kit not lighting.
Solutions:
1. Check wall switch to fan.
2. Check that bulbs are installed correctly.
3. Check to be sure code switches are set properly.
4. Verify that molex connections in switch housing
are connected properly.
5. Check to be sure that bulb totals no more than
190W. [Note: Lamping the light kit with bulb that totals
more than 190W will cause the wattage limiting device to
interrupt the flow of electricity to the light kit.
Problem: Fan operates but lights fail.
Solutions:
1. Check that bulbs are installed correctly.
2. Replace defective bulbs with same type of bulb.
3. Check to be sure wires in canopy are wired
properly.
4. Verify that molex connections in switch housing
are connected properly.
5. Check to be sure that bulb totals no more than
190W. [Note: Lamping the light kit with bulb that totals
more than 190W will cause the wattage limiting device to
interrupt the flow of electricity to the light kit
Problem: Fan and light fail to operate with remote
control.
Solutions:
1. Check battery power to remote control.
2. Check to be sure code switches in remote
control transmitter and receiver are set properly.
Problem: Fan wobbles.
Solutions:
1. Use the balancing kit located in one the
hardware packs. If no blade balancing kit is
provided, please call Customer
Support,1-800-527-1292, to request one.
2. Check to be sure set screw(s) on motor housing
yoke is (are) tightened securely.
3. Check to be sure set screw on hanging ball is
tightened securely.